sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Thakur, R. K.

Normalized to: Thakur, R.

43 article(s) in total. 670 co-authors, from 1 to 25 common article(s). Median position in authors list is 6,0.

[1]  oai:arXiv.org:2006.11721  [pdf] - 2119166
Measurement of Hubble Constant: Do Different Cosmological Probes Provide Different Values?
Comments: 18 pages, 3 figures
Submitted: 2020-06-21
Different measurements of the Hubble constant ($H_{0}$) are not consistent and a tension between the CMB based methods and cosmic distance ladder based methods has been observed. Measurements from various distance based methods are also inconsistent. To aggravate the problem, same cosmological probe (Type Ia SNe for instance) calibrated through different methods also provide different value of $H_{0}$. We compare various distance ladder based methods through the already available unique data obtained from Hubble Space Telescope (HST). Our analysis is based on parametric (T-test) as well as non-parametric statistical methods such as the Mann-Whitney U test and Kolmogorov-Smirnov test. Our results show that different methods provide different values of $H_0$ and the differences are statistically significant. The biases in the calibration would not account for these differences as the data has been taken from a single telescope with common calibration scheme. The unknown physical effects or issues with the empirical relations of distance measurement from different probes could give rise to these differences.
[2]  oai:arXiv.org:1912.04272  [pdf] - 2072607
Broadband, millimeter-wave antireflection coatings for large-format, cryogenic aluminum oxide optics
Comments: 19 pages, 11 figures; submitted 05 Dec 2019, accepted 26 Feb 2020
Submitted: 2019-12-06, last modified: 2020-03-02
We present two prescriptions for broadband (~77 - 252 GHz), millimeter-wave antireflection coatings for cryogenic, sintered polycrystalline aluminum oxide optics: one for large-format (700 mm diameter) planar and plano-convex elements, the other for densely packed arrays of quasi-optical elements, in our case 5 mm diameter half-spheres (called "lenslets"). The coatings comprise three layers of commercially-available, polytetrafluoroethylene-based, dielectric sheet material. The lenslet coating is molded to fit the 150 mm diameter arrays directly while the large-diameter lenses are coated using a tiled approach. We review the fabrication processes for both prescriptions then discuss laboratory measurements of their transmittance and reflectance. In addition, we present the inferred refractive indices and loss tangents for the coating materials and the aluminum oxide substrate. We find that at 150 GHz and 300 K the large-format coating sample achieves (97 +/- 2)% transmittance and the lenslet coating sample achieves (94 +/- 3)% transmittance.
[3]  oai:arXiv.org:2002.05254  [pdf] - 2048106
Optical Design and Characterization of 40-GHz Detector and Module for the BICEP Array
Comments: 8 pages, 7 figures, Accepted by the Journal of Low Temperature Physics (Proceedings of the 18th International Workshop on Low Temperature Detectors)
Submitted: 2020-02-12
Families of cosmic inflation models predict a primordial gravitational-wave background that imprints B-mode polarization pattern in the Cosmic Microwave Background (CMB). High sensitivity instruments with wide frequency coverage and well-controlled systematic errors are needed to constrain the faint B-mode amplitude. We have developed antenna-coupled Transition Edge Sensor (TES) arrays for high-sensitivity polarized CMB observations over a wide range of millimeter-wave bands. BICEP Array, the latest phase of the BICEP/Keck experiment series, is a multi-receiver experiment designed to search for inflationary B-mode polarization to a precision $\sigma$(r) between 0.002 and 0.004 after 3 full years of observations, depending on foreground complexity and the degree of lensing removal. We describe the electromagnetic design and measured performance of BICEP Array low-frequency 40-GHz detector, their packaging in focal plane modules, and optical characterization including efficiency and beam matching between polarization pairs. We summarize the design and simulated optical performance, including an approach to improve the optical efficiency due to mismatch losses. We report the measured beam maps for a new broad-band corrugation design to minimize beam differential ellipticity between polarization pairs caused by interactions with the module housing frame, which helps minimize polarized beam mismatch that converts CMB temperature to polarization ($T \rightarrow P$) anisotropy in CMB maps.
[4]  oai:arXiv.org:2002.05228  [pdf] - 2048104
Design and performance of the first BICEP Array receiver
Comments: 9 pages, 5 figures, presented at LTD18 in Milan (July 2019), accepted on JLTP (February 2020)
Submitted: 2020-02-12
Branches of cosmic inflationary models, such as slow-roll inflation, predict a background of primordial gravitational waves that imprints a unique odd-parity B-mode pattern in the Cosmic Microwave Background (CMB) at amplitudes that are within experimental reach. The BICEP/Keck (BK) experiment targets this primordial signature, the amplitude of which is parameterized by the tensor-to-scalar ratio r, by observing the polarized microwave sky through the exceptionally clean and stable atmosphere at the South Pole. B-mode measurements require an instrument with exquisite sensitivity, tight control of systematics, and wide frequency coverage to disentangle the primordial signal from the Galactic foregrounds. BICEP Array represents the most recent stage of the BK program, and comprises four BICEP3-class receivers observing at 30/40, 95, 150 and 220/270 GHz. The 30/40 GHz receiver will be deployed at the South Pole during the 2019/2020 austral summer. After 3 full years of observations with 30,000+ detectors, BICEP Array will measure primordial gravitational waves to a precision $\sigma(r)$ between 0.002 and 0.004, depending on foreground complexity and the degree of lensing removal. In this paper we give an overview of the instrument, highlighting the design features in terms of cryogenics, magnetic shielding, detectors and readout architecture as well as reporting on the integration and tests that are ongoing with the first receiver at 30/40 GHz.
[5]  oai:arXiv.org:2002.05219  [pdf] - 2065429
Characterizing the Sensitivity of 40 GHz TES Bolometers for BICEP Array
Comments: Accepted for publication in Journal of Low Temperature Physics
Submitted: 2020-02-12
The BICEP/Keck (BK) experiment aims to detect the imprint of primordial gravitational waves in the Cosmic Microwave Background polarization, which would be direct evidence of the inflation theory. While the tensor-to-scalar ratio has been constrained to be r_0.05 < 0.06 at 95% c.l., further improvements on this upper limit are hindered by polarized Galactic foreground emissions and removal of gravitational lensing polarization. The 30/40 GHz receiver of the BICEP Array (BA) will deploy at the end of 2019 and will constrain the synchrotron foreground with unprecedented accuracy within the BK sky patch. We will show the design of the 30/40 GHz detectors and test results summarizing its performance. The low optical and atmospheric loading at these frequencies requires our TES detectors to have low saturation power in order to be photon-noise dominated. To realize the low thermal conductivity required from a 250 mK base temperature, we developed new bolometer leg designs. We will present the relevant measured detector parameters: G, Tc, Rn, Psat , and spectral bands, and noise spectra. We achieved a per bolometer NEP including all noise components of 2.07E-17 W/sqrt(Hz), including an anticipated photon noise level 1.54E-17 W/sqrt(Hz).
[6]  oai:arXiv.org:2002.05197  [pdf] - 2093193
Optical characterization of the Keck Array and BICEP3 CMB Polarimeters from 2016 to 2019
Comments: 8 pages, 3 figures. Accepted by the Journal of Low Temperature Physics (Proceedings of the 18th International Workshop on Low Temperature Detectors)
Submitted: 2020-02-12
The BICEP/Keck experiment (BK) is a series of small-aperture refracting telescopes observing degree-scale Cosmic Microwave Background (CMB) polarization from the South Pole in search of a primordial $B$-mode signature. This $B$-mode signal arises from primordial gravitational waves interacting with the CMB, and has amplitude parametrized by the tensor-to-scalar ratio $r$. Since 2016, BICEP3 and the Keck Array have been observing with 4800 total antenna-coupled transition-edge sensor detectors, with frequency bands spanning 95, 150, 220, and 270 GHz. Here we present the optical performance of these receivers from 2016 to 2019, including far-field beams measured in situ with an improved chopped thermal source and instrument spectral response measured with a field-deployable Fourier Transform Spectrometer. As a pair differencing experiment, an important systematic that must be controlled is the differential beam response between the co-located, orthogonally polarized detectors. We generate per-detector far-field beam maps and the corresponding differential beam mismatch that is used to estimate the temperature-to-polarization leakage in our CMB maps and to give feedback on detector and optics fabrication. The differential beam parameters presented here were estimated using improved low-level beam map analysis techniques, including efficient removal of non-Gaussian noise as well as improved spatial masking. These techniques help minimize systematic uncertainty in the beam analysis, with the goal of constraining the bias on $r$ induced by temperature-to-polarization leakage to be subdominant to the statistical uncertainty. This is essential as we progress to higher detector counts in the next generation of CMB experiments.
[7]  oai:arXiv.org:1909.01305  [pdf] - 2034407
Microwave multiplexing on the Keck Array
Comments: 9 pages, 11 figures, Accepted by the Journal of Low Temperature Physics (Proceedings of the 18th International Workshop on Low Temperature Detectors)
Submitted: 2019-09-03, last modified: 2020-01-17
We describe an on-sky demonstration of a microwave-multiplexing readout system in one of the receivers of the Keck Array, a polarimetry experiment observing the cosmic microwave background at the South Pole. During the austral summer of 2018-2019, we replaced the time-division multiplexing readout system with microwave-multiplexing components including superconducting microwave resonators coupled to radio-frequency superconducting quantum interference devices at the sub-Kelvin focal plane, coaxial-cable plumbing and amplification between room temperature and the cold stages, and a SLAC Microresonator Radio Frequency system for the warm electronics. In the range 5-6 GHz, a single coaxial cable reads out 528 channels. The readout system is coupled to transition-edge sensors, which are in turn coupled to 150-GHz slot-dipole phased-array antennas. Observations began in April 2019, and we report here on an initial characterization of the system performance.
[8]  oai:arXiv.org:1911.08047  [pdf] - 2000343
Particle Physics with the Cosmic Microwave Background with SPT-3G
Comments: 6 pages, 2 figures, TAUP 2019
Submitted: 2019-11-18
The cosmic microwave background (CMB) encodes information about the content and evolution of the universe. The presence of light, weakly interacting particles impacts the expansion history of the early universe, which alters the temperature and polarization anisotropies of the CMB. In this way, current measurements of the CMB place interesting constraints on the neutrino energy density and mass, as well as on the abundance of other possible light relativistic particle species. We present the status of an on-going 1500 sq. deg. survey with the SPT-3G receiver, a new mm-wavelength camera on the 10-m diameter South Pole Telescope (SPT). The SPT-3G camera consists of 16,000 superconducting transition edge sensors, a 10x increase over the previous generation camera, which allows it to map the CMB with an unprecedented combination of sensitivity and angular resolution. We highlight projected constraints on the abundance of sterile neutrinos and the sum of the neutrino masses for the SPT-3G survey, which could help determine the neutrino mass hierarchy.
[9]  oai:arXiv.org:1909.02100  [pdf] - 1956006
Superconducting On-chip Fourier Transform Spectrometer
Comments:
Submitted: 2019-09-04
Kinetic inductance in thin film superconductors has been used as the basis for low-temperature, low-noise photon detectors. In particular thin films such as NbTiN, TiN, NbN, the kinetic inductance effect is strongly non-linear in the applied current, which can be utilized to realize novel devices. We present results from transmission lines made with these materials, where DC (current) control is used to modulate the phase velocity thereby enabling an on-chip spectrometer. The utility of such compact spectrometers are discussed, along with their natural connection with parametric amplifiers.
[10]  oai:arXiv.org:1908.01062  [pdf] - 1928247
CMB-S4 Decadal Survey APC White Paper
Abazajian, Kevork; Addison, Graeme; Adshead, Peter; Ahmed, Zeeshan; Allen, Steven W.; Alonso, David; Alvarez, Marcelo; Amin, Mustafa A.; Anderson, Adam; Arnold, Kam S.; Baccigalupi, Carlo; Bailey, Kathy; Barkats, Denis; Barron, Darcy; Barry, Peter S.; Bartlett, James G.; Thakur, Ritoban Basu; Battaglia, Nicholas; Baxter, Eric; Bean, Rachel; Bebek, Chris; Bender, Amy N.; Benson, Bradford A.; Berger, Edo; Bhimani, Sanah; Bischoff, Colin A.; Bleem, Lindsey; Bock, James J.; Bocquet, Sebastian; Boddy, Kimberly; Bonato, Matteo; Bond, J. Richard; Borrill, Julian; Bouchet, François R.; Brown, Michael L.; Bryan, Sean; Burkhart, Blakesley; Buza, Victor; Byrum, Karen; Calabrese, Erminia; Calafut, Victoria; Caldwell, Robert; Carlstrom, John E.; Carron, Julien; Cecil, Thomas; Challinor, Anthony; Chang, Clarence L.; Chinone, Yuji; Cho, Hsiao-Mei Sherry; Cooray, Asantha; Crawford, Thomas M.; Crites, Abigail; Cukierman, Ari; Cyr-Racine, Francis-Yan; de Haan, Tijmen; de Zotti, Gianfranco; Delabrouille, Jacques; Demarteau, Marcel; Devlin, Mark; Di Valentino, Eleonora; Dobbs, Matt; Duff, Shannon; Duivenvoorden, Adriaan; Dvorkin, Cora; Edwards, William; Eimer, Joseph; Errard, Josquin; Essinger-Hileman, Thomas; Fabbian, Giulio; Feng, Chang; Ferraro, Simone; Filippini, Jeffrey P.; Flauger, Raphael; Flaugher, Brenna; Fraisse, Aurelien A.; Frolov, Andrei; Galitzki, Nicholas; Galli, Silvia; Ganga, Ken; Gerbino, Martina; Gilchriese, Murdock; Gluscevic, Vera; Green, Daniel; Grin, Daniel; Grohs, Evan; Gualtieri, Riccardo; Guarino, Victor; Gudmundsson, Jon E.; Habib, Salman; Haller, Gunther; Halpern, Mark; Halverson, Nils W.; Hanany, Shaul; Harrington, Kathleen; Hasegawa, Masaya; Hasselfield, Matthew; Hazumi, Masashi; Heitmann, Katrin; Henderson, Shawn; Henning, Jason W.; Hill, J. Colin; Hlozek, Renée; Holder, Gil; Holzapfel, William; Hubmayr, Johannes; Huffenberger, Kevin M.; Huffer, Michael; Hui, Howard; Irwin, Kent; Johnson, Bradley R.; Johnstone, Doug; Jones, William C.; Karkare, Kirit; Katayama, Nobuhiko; Kerby, James; Kernovsky, Sarah; Keskitalo, Reijo; Kisner, Theodore; Knox, Lloyd; Kosowsky, Arthur; Kovac, John; Kovetz, Ely D.; Kuhlmann, Steve; Kuo, Chao-lin; Kurita, Nadine; Kusaka, Akito; Lahteenmaki, Anne; Lawrence, Charles R.; Lee, Adrian T.; Lewis, Antony; Li, Dale; Linder, Eric; Loverde, Marilena; Lowitz, Amy; Madhavacheril, Mathew S.; Mantz, Adam; Matsuda, Frederick; Mauskopf, Philip; McMahon, Jeff; Meerburg, P. Daniel; Melin, Jean-Baptiste; Meyers, Joel; Millea, Marius; Mohr, Joseph; Moncelsi, Lorenzo; Mroczkowski, Tony; Mukherjee, Suvodip; Münchmeyer, Moritz; Nagai, Daisuke; Nagy, Johanna; Namikawa, Toshiya; Nati, Federico; Natoli, Tyler; Negrello, Mattia; Newburgh, Laura; Niemack, Michael D.; Nishino, Haruki; Nordby, Martin; Novosad, Valentine; O'Connor, Paul; Obied, Georges; Padin, Stephen; Pandey, Shivam; Partridge, Bruce; Pierpaoli, Elena; Pogosian, Levon; Pryke, Clement; Puglisi, Giuseppe; Racine, Benjamin; Raghunathan, Srinivasan; Rahlin, Alexandra; Rajagopalan, Srini; Raveri, Marco; Reichanadter, Mark; Reichardt, Christian L.; Remazeilles, Mathieu; Rocha, Graca; Roe, Natalie A.; Roy, Anirban; Ruhl, John; Salatino, Maria; Saliwanchik, Benjamin; Schaan, Emmanuel; Schillaci, Alessandro; Schmittfull, Marcel M.; Scott, Douglas; Sehgal, Neelima; Shandera, Sarah; Sheehy, Christopher; Sherwin, Blake D.; Shirokoff, Erik; Simon, Sara M.; Slosar, Anze; Somerville, Rachel; Staggs, Suzanne T.; Stark, Antony; Stompor, Radek; Story, Kyle T.; Stoughton, Chris; Suzuki, Aritoki; Tajima, Osamu; Teply, Grant P.; Thompson, Keith; Timbie, Peter; Tomasi, Maurizio; Treu, Jesse I.; Tristram, Matthieu; Tucker, Gregory; Umiltà, Caterina; van Engelen, Alexander; Vieira, Joaquin D.; Vieregg, Abigail G.; Vogelsberger, Mark; Wang, Gensheng; Watson, Scott; White, Martin; Whitehorn, Nathan; Wollack, Edward J.; Wu, W. L. Kimmy; Xu, Zhilei; Yasini, Siavash; Yeck, James; Yoon, Ki Won; Young, Edward; Zonca, Andrea
Comments: Project White Paper submitted to the 2020 Decadal Survey, 10 pages plus references. arXiv admin note: substantial text overlap with arXiv:1907.04473
Submitted: 2019-07-31
We provide an overview of the science case, instrument configuration and project plan for the next-generation ground-based cosmic microwave background experiment CMB-S4, for consideration by the 2020 Decadal Survey.
[11]  oai:arXiv.org:1907.12602  [pdf] - 1953685
Stability of Gluonic Systems with Multiple Soft Interactions
Comments: Keywords: Extensive Air Showers, Multiple Soft Interactions, Cosmic Rays, Gluon Density Fluctuations, Astroparticle Physics, 32 pages; 5 figures; Accepted to appear in Journal of Astrophysics and Astronomy
Submitted: 2019-07-29
In this paper, we investigate the stability properties of soft gluons in SIBYLL 2.1 with reference to its original version 1.7 that corresponds to hadronic hard interactions. In order to investigate the stability structures, we classify the regions of the gluon density fluctuations in its double leading logarithmic approximation and its equivalent description as the fractional power law. In the parameter space of initial transverse momentum $Q$ and QCD renormalization scale $L$ that correspond to extensive air showers of cosmic rays, we have categorized the surface of parameters over which the proton is stable. We further discuss the nature of local and global correlations and stability properties where the concerning statistical basis yields a stable system or undergoes a geometric phase transition. Finally, we give a phenomenological understanding towards the stability of soft interactions, Pomeron particle productions in minijet model, string fragmentation and verify our result corresponding to the experiments - CDF, P238, UAS, GEUS and UA4 collaborations.
[12]  oai:arXiv.org:1907.11976  [pdf] - 2025648
Performance of Al-Mn Transition-Edge Sensor Bolometers in SPT-3G
Comments: 9 pages, 5 figures, submitted to the Journal of Low Temperature Physics: LTD18 Special Edition
Submitted: 2019-07-27
SPT-3G is a polarization-sensitive receiver, installed on the South Pole Telescope, that measures the anisotropy of the cosmic microwave background (CMB) from degree to arcminute scales. The receiver consists of ten 150~mm-diameter detector wafers, containing a total of 16,000 transition-edge sensor (TES) bolometers observing at 95, 150, and 220 GHz. During the 2018-2019 austral summer, one of these detector wafers was replaced by a new wafer fabricated with Al-Mn TESs instead of the Ti/Au design originally deployed for SPT-3G. We present the results of in-lab characterization and on-sky performance of this Al-Mn wafer, including electrical and thermal properties, optical efficiency measurements, and noise-equivalent temperature. In addition, we discuss and account for several calibration-related systematic errors that affect measurements made using frequency-domain multiplexing readout electronics.
[13]  oai:arXiv.org:1907.10947  [pdf] - 2025643
On-sky performance of the SPT-3G frequency-domain multiplexed readout
Comments: 9 pages, 5 figures submitted to the Journal of Low Temperature Physics: LTD18 Special Edition
Submitted: 2019-07-25
Frequency-domain multiplexing (fMux) is an established technique for the readout of large arrays of transition edge sensor (TES) bolometers. Each TES in a multiplexing module has a unique AC voltage bias that is selected by a resonant filter. This scheme enables the operation and readout of multiple bolometers on a single pair of wires, reducing thermal loading onto sub-Kelvin stages. The current receiver on the South Pole Telescope, SPT-3G, uses a 68x fMux system to operate its large-format camera of $\sim$16,000 TES bolometers. We present here the successful implementation and performance of the SPT-3G readout as measured on-sky. Characterization of the noise reveals a median pair-differenced 1/f knee frequency of 33 mHz, indicating that low-frequency noise in the readout will not limit SPT-3G's measurements of sky power on large angular scales. Measurements also show that the median readout white noise level in each of the SPT-3G observing bands is below the expectation for photon noise, demonstrating that SPT-3G is operating in the photon-noise-dominated regime.
[14]  oai:arXiv.org:1907.04473  [pdf] - 1914295
CMB-S4 Science Case, Reference Design, and Project Plan
Abazajian, Kevork; Addison, Graeme; Adshead, Peter; Ahmed, Zeeshan; Allen, Steven W.; Alonso, David; Alvarez, Marcelo; Anderson, Adam; Arnold, Kam S.; Baccigalupi, Carlo; Bailey, Kathy; Barkats, Denis; Barron, Darcy; Barry, Peter S.; Bartlett, James G.; Thakur, Ritoban Basu; Battaglia, Nicholas; Baxter, Eric; Bean, Rachel; Bebek, Chris; Bender, Amy N.; Benson, Bradford A.; Berger, Edo; Bhimani, Sanah; Bischoff, Colin A.; Bleem, Lindsey; Bocquet, Sebastian; Boddy, Kimberly; Bonato, Matteo; Bond, J. Richard; Borrill, Julian; Bouchet, François R.; Brown, Michael L.; Bryan, Sean; Burkhart, Blakesley; Buza, Victor; Byrum, Karen; Calabrese, Erminia; Calafut, Victoria; Caldwell, Robert; Carlstrom, John E.; Carron, Julien; Cecil, Thomas; Challinor, Anthony; Chang, Clarence L.; Chinone, Yuji; Cho, Hsiao-Mei Sherry; Cooray, Asantha; Crawford, Thomas M.; Crites, Abigail; Cukierman, Ari; Cyr-Racine, Francis-Yan; de Haan, Tijmen; de Zotti, Gianfranco; Delabrouille, Jacques; Demarteau, Marcel; Devlin, Mark; Di Valentino, Eleonora; Dobbs, Matt; Duff, Shannon; Duivenvoorden, Adriaan; Dvorkin, Cora; Edwards, William; Eimer, Joseph; Errard, Josquin; Essinger-Hileman, Thomas; Fabbian, Giulio; Feng, Chang; Ferraro, Simone; Filippini, Jeffrey P.; Flauger, Raphael; Flaugher, Brenna; Fraisse, Aurelien A.; Frolov, Andrei; Galitzki, Nicholas; Galli, Silvia; Ganga, Ken; Gerbino, Martina; Gilchriese, Murdock; Gluscevic, Vera; Green, Daniel; Grin, Daniel; Grohs, Evan; Gualtieri, Riccardo; Guarino, Victor; Gudmundsson, Jon E.; Habib, Salman; Haller, Gunther; Halpern, Mark; Halverson, Nils W.; Hanany, Shaul; Harrington, Kathleen; Hasegawa, Masaya; Hasselfield, Matthew; Hazumi, Masashi; Heitmann, Katrin; Henderson, Shawn; Henning, Jason W.; Hill, J. Colin; Hlozek, Renée; Holder, Gil; Holzapfel, William; Hubmayr, Johannes; Huffenberger, Kevin M.; Huffer, Michael; Hui, Howard; Irwin, Kent; Johnson, Bradley R.; Johnstone, Doug; Jones, William C.; Karkare, Kirit; Katayama, Nobuhiko; Kerby, James; Kernovsky, Sarah; Keskitalo, Reijo; Kisner, Theodore; Knox, Lloyd; Kosowsky, Arthur; Kovac, John; Kovetz, Ely D.; Kuhlmann, Steve; Kuo, Chao-lin; Kurita, Nadine; Kusaka, Akito; Lahteenmaki, Anne; Lawrence, Charles R.; Lee, Adrian T.; Lewis, Antony; Li, Dale; Linder, Eric; Loverde, Marilena; Lowitz, Amy; Madhavacheril, Mathew S.; Mantz, Adam; Matsuda, Frederick; Mauskopf, Philip; McMahon, Jeff; McQuinn, Matthew; Meerburg, P. Daniel; Melin, Jean-Baptiste; Meyers, Joel; Millea, Marius; Mohr, Joseph; Moncelsi, Lorenzo; Mroczkowski, Tony; Mukherjee, Suvodip; Münchmeyer, Moritz; Nagai, Daisuke; Nagy, Johanna; Namikawa, Toshiya; Nati, Federico; Natoli, Tyler; Negrello, Mattia; Newburgh, Laura; Niemack, Michael D.; Nishino, Haruki; Nordby, Martin; Novosad, Valentine; O'Connor, Paul; Obied, Georges; Padin, Stephen; Pandey, Shivam; Partridge, Bruce; Pierpaoli, Elena; Pogosian, Levon; Pryke, Clement; Puglisi, Giuseppe; Racine, Benjamin; Raghunathan, Srinivasan; Rahlin, Alexandra; Rajagopalan, Srini; Raveri, Marco; Reichanadter, Mark; Reichardt, Christian L.; Remazeilles, Mathieu; Rocha, Graca; Roe, Natalie A.; Roy, Anirban; Ruhl, John; Salatino, Maria; Saliwanchik, Benjamin; Schaan, Emmanuel; Schillaci, Alessandro; Schmittfull, Marcel M.; Scott, Douglas; Sehgal, Neelima; Shandera, Sarah; Sheehy, Christopher; Sherwin, Blake D.; Shirokoff, Erik; Simon, Sara M.; Slosar, Anze; Somerville, Rachel; Spergel, David; Staggs, Suzanne T.; Stark, Antony; Stompor, Radek; Story, Kyle T.; Stoughton, Chris; Suzuki, Aritoki; Tajima, Osamu; Teply, Grant P.; Thompson, Keith; Timbie, Peter; Tomasi, Maurizio; Treu, Jesse I.; Tristram, Matthieu; Tucker, Gregory; Umiltà, Caterina; van Engelen, Alexander; Vieira, Joaquin D.; Vieregg, Abigail G.; Vogelsberger, Mark; Wang, Gensheng; Watson, Scott; White, Martin; Whitehorn, Nathan; Wollack, Edward J.; Wu, W. L. Kimmy; Xu, Zhilei; Yasini, Siavash; Yeck, James; Yoon, Ki Won; Young, Edward; Zonca, Andrea
Comments: 287 pages, 82 figures
Submitted: 2019-07-09
We present the science case, reference design, and project plan for the Stage-4 ground-based cosmic microwave background experiment CMB-S4.
[15]  oai:arXiv.org:1806.06872  [pdf] - 1916736
Observationally inferred dark matter phase-space distribution and direct detection experiments
Comments: 13 pages, 10 figures, 4 tables, version accepted by PRD
Submitted: 2018-06-18, last modified: 2019-07-04
We present a detailed analysis of the effect of an observationally determined dark matter (DM) velocity distribution function (VDF) of the Milky Way (MW) on DM direct detection rates. We go beyond local kinematic tracers and use rotation curve data up to 200 kpc to construct a MW mass model and self-consistently determine the local phase-space distribution of DM. This approach mitigates any incomplete understanding of local dark matter-visible matter degeneracies that can affect the determination of the VDF. Comparing with the oft used Standard Halo Model (SHM), which assumes an isothermal VDF, we look at how the tail of the empirically determined VDF alters our interpretation of the present direct detection WIMP DM cross section exclusion limits. While previous studies have suggested a very large difference (of more than an order of magnitude) in the bounds at low DM masses, we show that accounting for the detector response at low threshold energies, the difference is still significant although less extreme. The change in the number of signal events, when using the empirically determined DM VDF in contrast to the SHM VDF, is most prominent for low DM masses for which the shape of the recoil energy spectrum depends sensitively on the detector threshold energy as well as detector response near the threshold. We demonstrate that these trends carry over to the respective DM exclusion limits, modulo detailed understanding of the experimental backgrounds. With the unprecedented precision of astrometric data in the GAIA era, use of observationally determined DM phase-space will become a critical and necessary ingredient for DM searches. We provide an accurate fit to the current best observationally determined DM VDF (and self-consistent local DM density) for use in analyzing current DM direct detection data by the experimental community.
[16]  oai:arXiv.org:1905.07399  [pdf] - 1953523
A Compact Millimeter-Wavelength Fourier-Transform Spectrometer
Comments: Submitted to Applied Optics. [Copyright 2019 Optical Society of America]. Users may use, reuse, and build upon the article, or use the article for text or data mining, so long as such uses are for non-commercial purposes and appropriate attribution is maintained. All other rights are reserved
Submitted: 2019-05-17
We have constructed a Fourier-transform spectrometer (FTS) operating between 50 and 330 GHz with minimum volume (355 x260 x64 mm) and weight (13 lbs) while maximizing optical throughput (100 $\mathrm{mm}^2$ sr) and optimizing the spectral resolution (4 GHz). This FTS is designed as a polarizing Martin-Puplett interferometer with unobstructed input and output in which both input polarizations undergo interference. The instrument construction is simple with mirrors milled on the box walls and one motorized stage as the single moving element. We characterize the performance of the FTS, compare the measurements to an optical simulation, and discuss features that relate to details of the FTS design. The simulation is also used to determine the tolerance of optical alignments for the required specifications. We detail the FTS mechanical design and provide the control software as well as the analysis code online.
[17]  oai:arXiv.org:1903.04218  [pdf] - 1873787
Spectral Distortions of the CMB as a Probe of Inflation, Recombination, Structure Formation and Particle Physics
Comments: Astro2020 Science White Paper, 5 pages text, 13 pages in total, 3 Figures, minor update to references
Submitted: 2019-03-11, last modified: 2019-04-25
Following the pioneering observations with COBE in the early 1990s, studies of the cosmic microwave background (CMB) have focused on temperature and polarization anisotropies. CMB spectral distortions - tiny departures of the CMB energy spectrum from that of a perfect blackbody - provide a second, independent probe of fundamental physics, with a reach deep into the primordial Universe. The theoretical foundation of spectral distortions has seen major advances in recent years, which highlight the immense potential of this emerging field. Spectral distortions probe a fundamental property of the Universe - its thermal history - thereby providing additional insight into processes within the cosmological standard model (CSM) as well as new physics beyond. Spectral distortions are an important tool for understanding inflation and the nature of dark matter. They shed new light on the physics of recombination and reionization, both prominent stages in the evolution of our Universe, and furnish critical information on baryonic feedback processes, in addition to probing primordial correlation functions at scales inaccessible to other tracers. In principle the range of signals is vast: many orders of magnitude of discovery space could be explored by detailed observations of the CMB energy spectrum. Several CSM signals are predicted and provide clear experimental targets, some of which are already observable with present-day technology. Confirmation of these signals would extend the reach of the CSM by orders of magnitude in physical scale as the Universe evolves from the initial stages to its present form. The absence of these signals would pose a huge theoretical challenge, immediately pointing to new physics.
[18]  oai:arXiv.org:1903.11744  [pdf] - 1857808
Tomography of the Cosmic Dawn and Reionization Eras with Multiple Tracers
Comments: Astro2020 Science White Paper; 5 pages, 1 figure
Submitted: 2019-03-27
The Cosmic Dawn and Reionization epochs remain a fundamental but challenging frontier of astrophysics and cosmology. We advocate a large-scale, multi-tracer approach to develop a comprehensive understanding of the physics that led to the formation and evolution of the first stars and galaxies. We highlight the line intensity mapping technique to trace the multi-phase reionization topology on large scales, and measure reionization history in detail. Besides 21cm, we advocate for Lya tomography mapping during the epoch of Wouthuysen-Field coupling as an additional probe of the cosmic dawn era.
[19]  oai:arXiv.org:1902.09640  [pdf] - 1838469
Design and Bolometer Characterization of the SPT-3G First-year Focal Plane
Comments: Conference proceeding for Low Temperature Detectors 2017. Accepted for publication: 27 August 2018
Submitted: 2019-02-25
During the austral summer of 2016-17, the third-generation camera, SPT-3G, was installed on the South Pole Telescope, increasing the detector count in the focal plane by an order of magnitude relative to the previous generation. Designed to map the polarization of the cosmic microwave background, SPT-3G contains ten 6-in-hexagonal modules of detectors, each with 269 trichroic and dual-polarization pixels, read out using 68x frequency-domain multiplexing. Here we discuss design, assembly, and layout of the modules, as well as early performance characterization of the first-year array, including yield and detector properties.
[20]  oai:arXiv.org:1809.00033  [pdf] - 1743941
Characterization and performance of the second-year SPT-3G focal plane
Comments: 13 pages, 11 figures
Submitted: 2018-08-31
The third-generation instrument for the 10-meter South Pole Telescope, SPT-3G, was first installed in January 2017. In addition to completely new cryostats, secondary telescope optics, and readout electronics, the number of detectors in the focal plane has increased by an order of magnitude from previous instruments to ~16,000. The SPT-3G focal plane consists of ten detector modules, each with an array of 269 trichroic, polarization-sensitive pixels on a six-inch silicon wafer. Within each pixel is a broadband, dual-polarization sinuous antenna; the signal from each orthogonal linear polarization is divided into three frequency bands centered at 95, 150, and 220 GHz by in-line lumped element filters and transmitted via superconducting microstrip to Ti/Au transition-edge sensor (TES) bolometers. Properties of the TES film, microstrip filters, and bolometer island must be tightly controlled to achieve optimal performance. For the second year of SPT-3G operation, we have replaced all ten wafers in the focal plane with new detector arrays tuned to increase mapping speed and improve overall performance. Here we discuss the TES superconducting transition temperature and normal resistance, detector saturation power, bandpasses, optical efficiency, and full array yield for the 2018 focal plane.
[21]  oai:arXiv.org:1809.00036  [pdf] - 1743942
Year two instrument status of the SPT-3G cosmic microwave background receiver
Comments: 21 pages, 9 Figures, Presented at SPIE Astronomical Telescopes + Instrumentation 2018
Submitted: 2018-08-31
The South Pole Telescope (SPT) is a millimeter-wavelength telescope designed for high-precision measurements of the cosmic microwave background (CMB). The SPT measures both the temperature and polarization of the CMB with a large aperture, resulting in high resolution maps sensitive to signals across a wide range of angular scales on the sky. With these data, the SPT has the potential to make a broad range of cosmological measurements. These include constraining the effect of massive neutrinos on large-scale structure formation as well as cleaning galactic and cosmological foregrounds from CMB polarization data in future searches for inflationary gravitational waves. The SPT began observing in January 2017 with a new receiver (SPT-3G) containing $\sim$16,000 polarization-sensitive transition-edge sensor bolometers. Several key technology developments have enabled this large-format focal plane, including advances in detectors, readout electronics, and large millimeter-wavelength optics. We discuss the implementation of these technologies in the SPT-3G receiver as well as the challenges they presented. In late 2017 the implementations of all three of these technologies were modified to optimize total performance. Here, we present the current instrument status of the SPT-3G receiver.
[22]  oai:arXiv.org:1809.00032  [pdf] - 1743940
Design and characterization of the SPT-3G receiver
Comments: Conference Presentation at SPIE Astronomical Telescopes + Instrumentation 2018, conference 10708
Submitted: 2018-08-31
The SPT-3G receiver was commissioned in early 2017 on the 10-meter South Pole Telescope (SPT) to map anisotropies in the cosmic microwave background (CMB). New optics, detector, and readout technologies have yielded a multichroic, high-resolution, low-noise camera with impressive throughput and sensitivity, offering the potential to improve our understanding of inflationary physics, astroparticle physics, and growth of structure. We highlight several key features and design principles of the new receiver, and summarize its performance to date.
[23]  oai:arXiv.org:1809.00030  [pdf] - 1848536
Broadband anti-reflective coatings for cosmic microwave background experiments
Comments: 13 pages, 5 figures
Submitted: 2018-08-31
The desire for higher sensitivity has driven ground-based cosmic microwave background (CMB) experiments to employ ever larger focal planes, which in turn require larger reimaging optics. Practical limits to the maximum size of these optics motivates the development of quasi-optically-coupled (lenslet-coupled), multi-chroic detectors. These detectors can be sensitive across a broader bandwidth compared to waveguide-coupled detectors. However, the increase in bandwidth comes at a cost: the lenses (up to $\sim$700 mm diameter) and lenslets ($\sim$5 mm diameter, hemispherical lenses on the focal plane) used in these systems are made from high-refractive-index materials (such as silicon or amorphous aluminum oxide) that reflect nearly a third of the incident radiation. In order to maximize the faint CMB signal that reaches the detectors, the lenses and lenslets must be coated with an anti-reflective (AR) material. The AR coating must maximize radiation transmission in scientifically interesting bands and be cryogenically stable. Such a coating was developed for the third generation camera, SPT-3G, of the South Pole Telescope (SPT) experiment, but the materials and techniques used in the development are general to AR coatings for mm-wave optics. The three-layer polytetrafluoroethylene-based AR coating is broadband, inexpensive, and can be manufactured with simple tools. The coating is field tested; AR coated focal plane elements were deployed in the 2016-2017 austral summer and AR coated reimaging optics were deployed in 2017-2018.
[24]  oai:arXiv.org:1803.02903  [pdf] - 1724039
Nuclear-recoil energy scale in CDMS II silicon dark-matter detectors
Comments: 22 pages, 17 figures, 1 table, 1 appendix
Submitted: 2018-03-07, last modified: 2018-07-27
The Cryogenic Dark Matter Search (CDMS II) experiment aims to detect dark matter particles that elastically scatter from nuclei in semiconductor detectors. The resulting nuclear-recoil energy depositions are detected by ionization and phonon sensors. Neutrons produce a similar spectrum of low-energy nuclear recoils in such detectors, while most other backgrounds produce electron recoils. The absolute energy scale for nuclear recoils is necessary to interpret results correctly. The energy scale can be determined in CDMS II silicon detectors using neutrons incident from a broad-spectrum $^{252}$Cf source, taking advantage of a prominent resonance in the neutron elastic scattering cross section of silicon at a recoil (neutron) energy near 20 (182) keV. Results indicate that the phonon collection efficiency for nuclear recoils is $4.8^{+0.7}_{-0.9}$% lower than for electron recoils of the same energy. Comparisons of the ionization signals for nuclear recoils to those measured previously by other groups at higher electric fields indicate that the ionization collection efficiency for CDMS II silicon detectors operated at $\sim$4 V/cm is consistent with 100% for nuclear recoils below 20 keV and gradually decreases for larger energies to $\sim$75% at 100 keV. The impact of these measurements on previously published CDMS II silicon results is small.
[25]  oai:arXiv.org:1805.03219  [pdf] - 1679898
Optical Characterization of the SPT-3G Focal Plane
Comments: Conference proceeding for Low Temperature Detectors 2017
Submitted: 2018-05-08
The third-generation South Pole Telescope camera is designed to measure the cosmic microwave background across three frequency bands (95, 150 and 220 GHz) with ~16,000 transition-edge sensor (TES) bolometers. Each multichroic pixel on a detector wafer has a broadband sinuous antenna that couples power to six TESs, one for each of the three observing bands and both polarization directions, via lumped element filters. Ten detector wafers populate the focal plane, which is coupled to the sky via a large-aperture optical system. Here we present the frequency band characterization with Fourier transform spectroscopy, measurements of optical time constants, beam properties, and optical and polarization efficiencies of the focal plane. The detectors have frequency bands consistent with our simulations, and have high average optical efficiency which is 86%, 77% and 66% for the 95, 150 and 220 GHz detectors. The time constants of the detectors are mostly between 0.5 ms and 5 ms. The beam is round with the correct size, and the polarization efficiency is more than 90% for most of the bolometers
[26]  oai:arXiv.org:1707.01632  [pdf] - 1622232
Low-Mass Dark Matter Search with CDMSlite
Comments: 30 Pages, 33 Figures v3 to match published version in PRD. v2 contains public release (and documentation) of the CDMSlite Run 2 data as ancillary files
Submitted: 2017-07-06, last modified: 2018-01-18
The SuperCDMS experiment is designed to directly detect weakly interacting massive particles (WIMPs) that may constitute the dark matter in our Galaxy. During its operation at the Soudan Underground Laboratory, germanium detectors were run in the CDMSlite mode to gather data sets with sensitivity specifically for WIMPs with masses ${<}$10 GeV/$c^2$. In this mode, a higher detector-bias voltage is applied to amplify the phonon signals produced by drifting charges. This paper presents studies of the experimental noise and its effect on the achievable energy threshold, which is demonstrated to be as low as 56 eV$_{\text{ee}}$ (electron equivalent energy). The detector-biasing configuration is described in detail, with analysis corrections for voltage variations to the level of a few percent. Detailed studies of the electric-field geometry, and the resulting successful development of a fiducial parameter, eliminate poorly measured events, yielding an energy resolution ranging from ${\sim}$9 eV$_{\text{ee}}$ at 0 keV to 101 eV$_{\text{ee}}$ at ${\sim}$10 eV$_{\text{ee}}$. New results are derived for astrophysical uncertainties relevant to the WIMP-search limits, specifically examining how they are affected by variations in the most probable WIMP velocity and the Galactic escape velocity. These variations become more important for WIMP masses below 10 GeV/$c^2$. Finally, new limits on spin-dependent low-mass WIMP-nucleon interactions are derived, with new parameter space excluded for WIMP masses $\lesssim$3 GeV/$c^2$
[27]  oai:arXiv.org:1711.01192  [pdf] - 1955840
Simulating Cosmic Microwave Background anisotropy measurements for Microwave Kinetic Inductance Devices
Comments:
Submitted: 2017-11-03
Microwave Kinetic Inductance Devices (MKIDs) are poised to allow for massively and natively multiplexed photon detectors arrays and are a natural choice for the next-generation CMB-Stage 4 experiment which will require 105 detectors. In this proceed- ing we discuss what noise performance of present generation MKIDs implies for CMB measurements. We consider MKID noise spectra and simulate a telescope scan strategy which projects the detector noise onto the CMB sky. We then analyze the simulated CMB + MKID noise to understand particularly low frequency noise affects the various features of the CMB, and thusly set up a framework connecting MKID characteristics with scan strategies, to the type of CMB signals we may probe with such detectors.
[28]  oai:arXiv.org:1710.11255  [pdf] - 1697946
Fabrication of antenna-coupled KID array for Cosmic Microwave Background detection
Comments: 7 pages, 9 figures, submitted to Journal of Low Temperature Physics
Submitted: 2017-10-30
Kinetic Inductance Detectors (KIDs) have become an attractive alternative to traditional bolometers in the sub-mm and mm observing community due to their innate frequency multiplexing capabilities and simple lithographic processes. These advantages make KIDs a viable option for the $O(500,000)$ detectors needed for the upcoming Cosmic Microwave Background - Stage 4 (CMB-S4) experiment. We have fabricated antenna-coupled MKID array in the 150GHz band optimized for CMB detection. Our design uses a twin slot antenna coupled to inverted microstrip made from a superconducting Nb/Al bilayer and SiN$_x$, which is then coupled to an Al KID grown on high resistivity Si. We present the fabrication process and measurements of SiN$_x$ microstrip resonators.
[29]  oai:arXiv.org:1706.02464  [pdf] - 1584411
CMB-S4 Technology Book, First Edition
Comments: 191 pages
Submitted: 2017-06-08, last modified: 2017-07-05
CMB-S4 is a proposed experiment to map the polarization of the Cosmic Microwave Background (CMB) to nearly the cosmic variance limit for angular scales that are accessible from the ground. The science goals and capabilities of CMB-S4 in illuminating cosmic inflation, measuring the sum of neutrino masses, searching for relativistic relics in the early universe, characterizing dark energy and dark matter, and mapping the matter distribution in the universe have been described in the CMB-S4 Science Book. This Technology Book is a companion volume to the Science Book. The ambitious science goals of CMB-S4, a "Stage-4" experiment, require a step forward in experimental capability from the current Stage=II experiments. To guide this process, we summarize the current state of CMB instrumentation technology, and identify R&D efforts necessary to advance it for use in CMB-S4. The book focuses on technical challenges in four broad areas: Telescope Design; Receiver Optics; Focal-Plane Optical Coupling; and Focal-Plane Sensor and Readout.
[30]  oai:arXiv.org:1610.00006  [pdf] - 1561019
Projected Sensitivity of the SuperCDMS SNOLAB experiment
Comments: SuperCDMS SNOLAB Projected sensitivity reach
Submitted: 2016-09-30
SuperCDMS SNOLAB will be a next-generation experiment aimed at directly detecting low-mass (< 10 GeV/c$^2$) particles that may constitute dark matter by using cryogenic detectors of two types (HV and iZIP) and two target materials (germanium and silicon). The experiment is being designed with an initial sensitivity to nuclear recoil cross sections ~ 1 x 10$^{-43}$ cm$^2$ for a dark matter particle mass of 1 GeV/c$^2$, and with capacity to continue exploration to both smaller masses and better sensitivities. The phonon sensitivity of the HV detectors will be sufficient to detect nuclear recoils from sub-GeV dark matter. A detailed calibration of the detector response to low energy recoils will be needed to optimize running conditions of the HV detectors and to interpret their data for dark matter searches. Low-activity shielding, and the depth of SNOLAB, will reduce most backgrounds, but cosmogenically produced $^{3}$H and naturally occurring $^{32}$Si will be present in the detectors at some level. Even if these backgrounds are x10 higher than expected, the science reach of the HV detectors would be over three orders of magnitude beyond current results for a dark matter mass of 1 GeV/c$^2$. The iZIP detectors are relatively insensitive to variations in detector response and backgrounds, and will provide better sensitivity for dark matter particle masses (> 5 GeV/c$^2$). The mix of detector types (HV and iZIP), and targets (germanium and silicon), planned for the experiment, as well as flexibility in how the detectors are operated, will allow us to maximize the low-mass reach, and understand the backgrounds that the experiment will encounter. Upgrades to the experiment, perhaps with a variety of ultra-low-background cryogenic detectors, will extend dark matter sensitivity down to the "neutrino floor", where coherent scatters of solar neutrinos become a limiting background.
[31]  oai:arXiv.org:1503.03379  [pdf] - 1458536
Dark matter effective field theory scattering in direct detection experiments
Comments: Newest version includes erratum
Submitted: 2015-03-11, last modified: 2016-08-16
We examine the consequences of the effective field theory (EFT) of dark matter-nucleon scattering for current and proposed direct detection experiments. Exclusion limits on EFT coupling constants computed using the optimum interval method are presented for SuperCDMS Soudan, CDMS II, and LUX, and the necessity of combining results from multiple experiments in order to determine dark matter parameters is discussed. We demonstrate that spectral differences between the standard dark matter model and a general EFT interaction can produce a bias when calculating exclusion limits and when developing signal models for likelihood and machine learning techniques. We also discuss the implications of the EFT for the next-generation (G2) direct detection experiments and point out regions of complementarity in the EFT parameter space.
[32]  oai:arXiv.org:1509.02448  [pdf] - 1371572
WIMP-Search Results from the Second CDMSlite Run
Comments: 6 pages, 4 figures. v2 Matches the accepted version in PRL
Submitted: 2015-09-08, last modified: 2016-03-09
The CDMS low ionization threshold experiment (CDMSlite) uses cryogenic germanium detectors operated at a relatively high bias voltage to amplify the phonon signal in the search for weakly interacting massive particles (WIMPs). Results are presented from the second CDMSlite run with an exposure of 70 kg days, which reached an energy threshold for electron recoils as low as 56 eV. A fiducialization cut reduces backgrounds below those previously reported by CDMSlite. New parameter space for the WIMP-nucleon spin-independent cross section is excluded for WIMP masses between 1.6 and 5.5 GeV/$c^2$.
[33]  oai:arXiv.org:1504.05871  [pdf] - 1293576
Improved WIMP-search reach of the CDMS II germanium data
Comments: 25 pages, 15 figures, slightly updated organization and text consistent with PRD referee process, Fig. 14 updated
Submitted: 2015-04-22, last modified: 2015-10-13
CDMS II data from the 5-tower runs at the Soudan Underground Laboratory were reprocessed with an improved charge-pulse fitting algorithm. Two new analysis techniques to reject surface-event backgrounds were applied to the 612 kg days germanium-detector WIMP-search exposure. An extended analysis was also completed by decreasing the 10 keV analysis threshold to $\sim$5 keV, to increase sensitivity near a WIMP mass of 8 GeV/$c^2$. After unblinding, there were zero candidate events above a deposited energy of 10 keV and 6 events in the lower-threshold analysis. This yielded minimum WIMP-nucleon spin-independent scattering cross-section limits of $1.8 \times 10^{-44}$ and $1.18 \times 10 ^{-41}$ cm$^2$ at 90\% confidence for 60 and 8.6 GeV/$c^2$ WIMPs, respectively. This improves the previous CDMS II result by a factor of 2.4 (2.7) for 60 (8.6) GeV/$c^2$ WIMPs.
[34]  oai:arXiv.org:1409.3270  [pdf] - 969775
First direct limits on Lightly Ionizing Particles with electric charge less than $e/6$
Comments: 5 pages, 6 figures, submitted to PRL
Submitted: 2014-09-10, last modified: 2015-02-03
While the Standard Model of particle physics does not include free particles with fractional charge, experimental searches have not ruled out their existence. We report results from the Cryogenic Dark Matter Search (CDMS II) experiment that give the first direct-detection limits for cosmogenically-produced relativistic particles with electric charge lower than $e$/6. A search for tracks in the six stacked detectors of each of two of the CDMS II towers found no candidates, thereby excluding new parameter space for particles with electric charges between $e$/6 and $e$/200.
[35]  oai:arXiv.org:1410.1003  [pdf] - 975596
Maximum Likelihood Analysis of Low Energy CDMS II Germanium Data
Comments: 12 pages, 12 figures, submitted to PRD
Submitted: 2014-10-03
We report on the results of a search for a Weakly Interacting Massive Particle (WIMP) signal in low-energy data of the Cryogenic Dark Matter Search (CDMS~II) experiment using a maximum likelihood analysis. A background model is constructed using GEANT4 to simulate the surface-event background from $^{210}$Pb decay-chain events, while using independent calibration data to model the gamma background. Fitting this background model to the data results in no statistically significant WIMP component. In addition, we perform fits using an analytic ad hoc background model proposed by Collar and Fields, who claimed to find a large excess of signal-like events in our data. We confirm the strong preference for a signal hypothesis in their analysis under these assumptions, but excesses are observed in both single- and multiple-scatter events, which implies the signal is not caused by WIMPs, but rather reflects the inadequacy of their background model.
[36]  oai:arXiv.org:1402.7137  [pdf] - 841566
Search for Low-Mass WIMPs with SuperCDMS
Comments: 6 pages, 4 figures; figure 1 updated, submitted to Phys. Rev. Lett
Submitted: 2014-02-28, last modified: 2014-03-12
We report a first search for weakly interacting massive particles (WIMPs) using the background rejection capabilities of SuperCDMS. An exposure of 577 kg-days was analyzed for WIMPs with mass < 30 GeV/c2, with the signal region blinded. Eleven events were observed after unblinding. We set an upper limit on the spin-independent WIMP-nucleon cross section of 1.2e-42 cm2 at 8 GeV/c2. This result is in tension with WIMP interpretations of recent experiments and probes new parameter space for WIMP-nucleon scattering for WIMP masses < 6 GeV/c2.
[37]  oai:arXiv.org:1309.3259  [pdf] - 779590
CDMSlite: A Search for Low-Mass WIMPs using Voltage-Assisted Calorimetric Ionization Detection in the SuperCDMS Experiment
Comments: 7 pages, 4 figures
Submitted: 2013-09-12, last modified: 2013-12-20
SuperCDMS is an experiment designed to directly detect Weakly Interacting Massive Particles (WIMPs), a favored candidate for dark matter ubiquitous in the Universe. In this paper, we present WIMP-search results using a calorimetric technique we call CDMSlite, which relies on voltage- assisted Luke-Neganov amplification of the ionization energy deposited by particle interactions. The data were collected with a single 0.6 kg germanium detector running for 10 live days at the Soudan Underground Laboratory. A low energy threshold of 170 eVee (electron equivalent) was obtained, which allows us to constrain new WIMP-nucleon spin-independent parameter space for WIMP masses below 6 GeV/c2.
[38]  oai:arXiv.org:1304.4279  [pdf] - 732067
Silicon Detector Dark Matter Results from the Final Exposure of CDMS II
Comments: 5 pages, 4 figures, as accepted by PRL
Submitted: 2013-04-15, last modified: 2013-10-11
We report results of a search for Weakly Interacting Massive Particles (WIMPS) with the silicon detectors of the CDMS II experiment. This blind analysis of 140.2 kg-days of data taken between July 2007 and September 2008 revealed three WIMP-candidate events with a surface-event background estimate of 0.41^{+0.20}_{-0.08}(stat.)^{+0.28}_{-0.24}(syst.). Other known backgrounds from neutrons and 206Pb are limited to < 0.13 and <0.08 events at the 90% confidence level, respectively. The exposure of this analysis is equivalent to 23.4 kg-days for a recoil energy range of 7-100 keV for a WIMP of mass 10 GeV/c2. The probability that the known backgrounds would produce three or more events in the signal region is 5.4%. A profile likelihood ratio test of the three events that includes the measured recoil energies gives a 0.19% probability for the known-background-only hypothesis when tested against the alternative WIMP+background hypothesis. The highest likelihood occurs for a WIMP mass of 8.6 GeV/c2 and WIMP-nucleon cross section of 1.9e-41 cm2.
[39]  oai:arXiv.org:1305.2405  [pdf] - 1530127
Demonstration of Surface Electron Rejection with Interleaved Germanium Detectors for Dark Matter Searches
Comments: 5 pages, 4 figures, submitted to journal
Submitted: 2013-05-10, last modified: 2013-10-04
The SuperCDMS experiment in the Soudan Underground Laboratory searches for dark matter with a 9-kg array of cryogenic germanium detectors. Symmetric sensors on opposite sides measure both charge and phonons from each particle interaction, providing excellent discrimination between electron and nuclear recoils, and between surface and interior events. Surface event rejection capabilities were tested with two $^{210}$Pb sources producing $\sim$130 beta decays/hr. In $\sim$800 live hours, no events leaked into the 8--115 keV signal region, giving upper limit leakage fraction $1.7 \times 10^{-5}$ at 90% C.L., corresponding to $< 0.6$ surface event background in the future 200-kg SuperCDMS SNOLAB experiment.
[40]  oai:arXiv.org:1304.3706  [pdf] - 719385
Silicon detector results from the first five-tower run of CDMS II
Comments: 5 pages, 4 figures; updated to match published version
Submitted: 2013-04-12, last modified: 2013-09-14
We report results of a search for Weakly Interacting Massive Particles (WIMPs) with the Si detectors of the CDMS II experiment. This report describes a blind analysis of the first data taken with CDMS II's full complement of detectors in 2006-2007; results from this exposure using the Ge detectors have already been presented. We observed no candidate WIMP-scattering events in an exposure of 55.9 kg-days before analysis cuts, with an expected background of ~1.1 events. The exposure of this analysis is equivalent to 10.3 kg-days over a recoil energy range of 7-100 keV for an ideal Si detector and a WIMP mass of 10 GeV/c2. These data set an upper limit of 1.7x10-41 cm2 on the WIMP-nucleon spin-independent cross section of a 10 GeV/c2 WIMP. These data exclude parameter space for spin-independent WIMP-nucleon elastic scattering that is relevant to recent searches for low-mass WIMPs.
[41]  oai:arXiv.org:1203.1309  [pdf] - 564223
Search for annual modulation in low-energy CDMS-II data
Comments: 5 pages, plus 8 pages supplementary materials
Submitted: 2012-03-06, last modified: 2012-09-18
We report limits on annual modulation of the low-energy event rate from the Cryogenic Dark Matter Search (CDMS II) experiment at the Soudan Underground Laboratory. Such a modulation could be produced by interactions from Weakly Interacting Massive Particles (WIMPs) with masses ~10 GeV/c^2. We find no evidence for annual modulation in the event rate of veto-anticoincident single-detector interactions consistent with nuclear recoils, and constrain the magnitude of any modulation to <0.06 event [keVnr kg day]^-1 in the 5-11.9 keVnr energy range at the 99% confidence level. These results disfavor an explanation for the reported modulation in the 1.2-3.2 keVee energy range in CoGeNT in terms of nuclear recoils resulting from elastic scattering of WIMPs at >98% confidence. For events consistent with electron recoils, no significant modulation is observed for either single- or multiple-detector interactions in the 3.0-7.4 keVee range.
[42]  oai:arXiv.org:1201.3685  [pdf] - 1093064
Low-Mass WIMP Sensitivity and Statistical Discrimination of Electron and Nuclear Recoils by Varying Luke-Neganov Phonon Gain in Semiconductor Detectors
Comments: 6 pages, 5 figures To be published in Journal of Low Temperature Physics
Submitted: 2012-01-17
Amplifying the phonon signal in a semiconductor dark matter detector can be accomplished by operating at high voltage bias and converting the electrostatic potential energy into Luke-Neganov phonons. This amplification method has been validated at up to |E|=40V/cm without producing leakage in CDMSII Ge detectors, allowing sensitivity to a benchmark WIMP with mass = 8GeV and cross section 1.8e-42cm^2 assuming flat electronic recoil backgrounds near threshold. Furthermore, for the first time we show that differences in Luke-Neganov gain for nuclear and electronic recoils can be used to discriminate statistically between low-energy background and a hypothetical WIMP signal by operating at two distinct voltage biases. Specifically, 99% of events have p-value<1e-8 for a simulated 20kg-day experiment with a benchmark WIMP signal with mass =8GeV and cross section =3.3e-41cm^2.
[43]  oai:arXiv.org:astro-ph/0702671  [pdf] - 89725
Do Black Holes End up as Quark Stars ?
Comments: 6 pages
Submitted: 2007-02-25
The possibility of the existence of quark stars has been discussed by several authors since 1970. Recently, it has been pointed out that two putative neutron stars, RXJ 1856.5 - 3754 in Corona Australis and 3C58 in Cassiopeia are too small and too dense to be neutron stars; they show evidence of being quark stars. Apart from these two objects, there are several other compact objects which fit neither in the category of neutron stars nor in that of black holes. It has been suggested that they may be quark stars.In this paper it is shown that a black hole cannot collapse to a singularity, instead it may end up as a quark star. In this context it is shown that a gravitationally collapsing black hole acts as an ultrahigh energy particle accelerator, hitherto inconceivable in any terrestrial laboratory, that continually accelerates particles comprising the matter in the black hole. When the energy \textit{E} of the particles in the black hole is $\geq 10^{2}$GeV, or equivalently the temperature \textit{T} of the matter in the black holes is $\geq 10^{15}$K, the entire matter in the black hole will be converted into quark-gluon plasma permeated by leptons. Since quarks and leptons are spin 1/2 particles,they are governed by Pauli's exclusion principle. Consequently, one of the two possibilities will occur; either Pauli's exclusion principle would be violated and the black hole would collapse to a singularity, or the collapse of the black hole to a singularity would be inhibited by Pauli's exclusion principle, and the black hole would eventually explode with a mini bang of a sort. After explosion, the remnant core would stabilize as a quark star.