Normalized to: Thakur, R.
[1]
oai:arXiv.org:2006.11721 [pdf] - 2119166
Measurement of Hubble Constant: Do Different Cosmological Probes Provide
Different Values?
Submitted: 2020-06-21
Different measurements of the Hubble constant ($H_{0}$) are not consistent
and a tension between the CMB based methods and cosmic distance ladder based
methods has been observed. Measurements from various distance based methods are
also inconsistent. To aggravate the problem, same cosmological probe (Type Ia
SNe for instance) calibrated through different methods also provide different
value of $H_{0}$. We compare various distance ladder based methods through the
already available unique data obtained from Hubble Space Telescope (HST). Our
analysis is based on parametric (T-test) as well as non-parametric statistical
methods such as the Mann-Whitney U test and Kolmogorov-Smirnov test. Our
results show that different methods provide different values of $H_0$ and the
differences are statistically significant. The biases in the calibration would
not account for these differences as the data has been taken from a single
telescope with common calibration scheme. The unknown physical effects or
issues with the empirical relations of distance measurement from different
probes could give rise to these differences.
[2]
oai:arXiv.org:1912.04272 [pdf] - 2072607
Broadband, millimeter-wave antireflection coatings for large-format,
cryogenic aluminum oxide optics
Nadolski, A.;
Vieira, J. D.;
Sobrin, J. A.;
Kofman, A. M.;
Ade, P. A. R.;
Ahmed, Z.;
Anderson, A. J.;
Avva, J. S.;
Thakur, R. Basu;
Bender, A. N.;
Benson, B. A.;
Bryant, L.;
Carlstrom, J. E.;
Carter, F. W.;
Cecil, T. W.;
Chang, C. L.;
Cheshire, J. R.;
Chesmore, G. E.;
Cliche, J. F.;
Cukierman, A.;
de Haan, T.;
Dierickx, M.;
Ding, J.;
Dutcher, D.;
Everett, W.;
Farwick, J.;
Ferguson, K. R.;
Florez, L.;
Foster, A.;
Fu, J.;
Gallicchio, J.;
Gambrel, A. E.;
Gardner, R. W.;
Groh, J. C.;
Guns, S.;
Guyser, R.;
Halverson, N. W.;
Harke-Hosemann, A. H.;
Harrington, N. L.;
Harris, R. J.;
Henning, J. W.;
Holzapfel, W. L.;
Howe, D.;
Huang, N.;
Irwin, K. D.;
Jeong, O.;
Jonas, M.;
Jones, A.;
Korman, M.;
Kovac, J.;
Kubik, D. L.;
Kuhlmann, S.;
Kuo, C. -L.;
Lee, A. T.;
Lowitz, A. E.;
McMahon, J.;
Meier, J.;
Meyer, S. S.;
Michalik, D.;
Montgomery, J.;
Natoli, T.;
Nguyen, H.;
Noble, G. I.;
Novosad, V.;
Padin, S.;
Pan, Z.;
Paschos, P.;
Pearson, J.;
sada, C. M. Po;
Quan, W.;
Rahlin, A.;
Riebel, D.;
Ruhl, J. E.;
Sayre, J. T.;
Shirokoff, E.;
Smecher, G.;
Stark, A. A.;
Stephen, J.;
Story, K. T.;
Suzuki, A.;
Tandoi, C.;
Thompson, K. L.;
Tucker, C.;
Vanderlinde, K.;
Wang, G.;
Whitehorn, N.;
Yefremenko, V.;
Yoon, K. W.;
Young, M. R.
Submitted: 2019-12-06, last modified: 2020-03-02
We present two prescriptions for broadband (~77 - 252 GHz), millimeter-wave
antireflection coatings for cryogenic, sintered polycrystalline aluminum oxide
optics: one for large-format (700 mm diameter) planar and plano-convex
elements, the other for densely packed arrays of quasi-optical elements, in our
case 5 mm diameter half-spheres (called "lenslets"). The coatings comprise
three layers of commercially-available, polytetrafluoroethylene-based,
dielectric sheet material. The lenslet coating is molded to fit the 150 mm
diameter arrays directly while the large-diameter lenses are coated using a
tiled approach. We review the fabrication processes for both prescriptions then
discuss laboratory measurements of their transmittance and reflectance. In
addition, we present the inferred refractive indices and loss tangents for the
coating materials and the aluminum oxide substrate. We find that at 150 GHz and
300 K the large-format coating sample achieves (97 +/- 2)% transmittance and
the lenslet coating sample achieves (94 +/- 3)% transmittance.
[3]
oai:arXiv.org:2002.05254 [pdf] - 2048106
Optical Design and Characterization of 40-GHz Detector and Module for
the BICEP Array
Soliman, A.;
Ade, P. A. R.;
Ahmed, Z.;
Amiri, M.;
Barkats, D.;
Thakur, R. Basu;
Bischoff, C. A.;
Bock, J. J.;
Boenish, H.;
Bullock, E.;
Buza, V.;
Cheshire, J.;
Connors, J.;
Cornelison, J.;
Crumrine, M.;
Cukierman, A.;
Dierickx, M.;
Duband, L.;
Fatigoni, S.;
Filippini, J. P.;
Hall, G.;
Halpern, M.;
Harrison, S.;
Henderson, S.;
Hildebrandt, S. R.;
Hilton, G. C.;
Hui, H.;
Irwin, K. D.;
Kang, J.;
Karkare, K. S.;
Karpel, E.;
Kefeli, S.;
Kovac, J. M.;
Kuo, C. L.;
Lau, K.;
Megerian, K. G.;
Moncelsi, L.;
Namikawa, T.;
Nguyen, H. T.;
OBrient, R.;
Palladino, S.;
Prouve, T.;
Precup, N.;
Pryke, C.;
Racine, B.;
Reintsema, C. D.;
Richter, S.;
Schmitt, B.;
Schwarz, R.;
Sheehy, C. D.;
Schillaci, A.;
Germaine, T. St.;
Steinbach, B.;
Sudiwala, R. V.;
Thompson, K. L.;
Tucker, C.;
Turner, A. D.;
Umilta, C.;
Vieregg, A. G.;
Wandui, A.;
Weber, A. C.;
Wiebe, D. V.;
Willmert, J.;
Wu, W. L. K.;
Yang, E.;
Yoon, K. W.;
Young, E.;
Yu, C.;
Zhang, C.
Submitted: 2020-02-12
Families of cosmic inflation models predict a primordial gravitational-wave
background that imprints B-mode polarization pattern in the Cosmic Microwave
Background (CMB). High sensitivity instruments with wide frequency coverage and
well-controlled systematic errors are needed to constrain the faint B-mode
amplitude. We have developed antenna-coupled Transition Edge Sensor (TES)
arrays for high-sensitivity polarized CMB observations over a wide range of
millimeter-wave bands. BICEP Array, the latest phase of the BICEP/Keck
experiment series, is a multi-receiver experiment designed to search for
inflationary B-mode polarization to a precision $\sigma$(r) between 0.002 and
0.004 after 3 full years of observations, depending on foreground complexity
and the degree of lensing removal. We describe the electromagnetic design and
measured performance of BICEP Array low-frequency 40-GHz detector, their
packaging in focal plane modules, and optical characterization including
efficiency and beam matching between polarization pairs. We summarize the
design and simulated optical performance, including an approach to improve the
optical efficiency due to mismatch losses. We report the measured beam maps for
a new broad-band corrugation design to minimize beam differential ellipticity
between polarization pairs caused by interactions with the module housing
frame, which helps minimize polarized beam mismatch that converts CMB
temperature to polarization ($T \rightarrow P$) anisotropy in CMB maps.
[4]
oai:arXiv.org:2002.05228 [pdf] - 2048104
Design and performance of the first BICEP Array receiver
Schillaci, A.;
Ade, P. A. R.;
Ahmed, Z.;
Amiri, M.;
Barkats, D.;
Thakur, R. Basu;
Bischoff, C. A.;
Bock, J. J.;
Boenish, H.;
Bullock, E.;
Buza, V.;
Cheshire, J.;
Connors, J.;
Cornelison, J.;
Crumrine, M.;
Cukierman, A.;
Dierickx, M.;
Duband, L.;
Fatigoni, S.;
Filippini, J. P.;
Hall, G.;
Halpern, M.;
Harrison, S.;
Henderson, S.;
Hildebrandt, S. R.;
Hilton, G. C.;
Hui, H.;
Irwin, K. D.;
Kang, J.;
Karkare, K. S.;
Karpel, E.;
Kefeli, S.;
Kovac, J. M.;
Kuo, C. L.;
Lau, K.;
Megerian, K. G.;
Moncelsi, L.;
Namikawa, T.;
Nguyen, H. T.;
O'Brient, R.;
Palladino, S.;
Precup, N.;
Prouvé, T.;
Pryke, C.;
Racine, B.;
Reintsema, C. D.;
Richter, S.;
Schmitt, B.;
Schwarz, R.;
Sheehy, C. D.;
Soliman, A.;
Germaine, T. St.;
Steinbach, B.;
Sudiwala, R. V.;
Thompson, K. L.;
Tucker, C.;
Turner, A. D.;
Umiltà, C.;
Vieregg, A. G.;
Wandui, A.;
Weber, A. C.;
Wiebe, D. V.;
Willmert, J.;
Wu, W. L. K.;
Yang, E.;
Yoon, K. W.;
Young, E.;
Yu, C.;
Zhang, C.
Submitted: 2020-02-12
Branches of cosmic inflationary models, such as slow-roll inflation, predict
a background of primordial gravitational waves that imprints a unique
odd-parity B-mode pattern in the Cosmic Microwave Background (CMB) at
amplitudes that are within experimental reach. The BICEP/Keck (BK) experiment
targets this primordial signature, the amplitude of which is parameterized by
the tensor-to-scalar ratio r, by observing the polarized microwave sky through
the exceptionally clean and stable atmosphere at the South Pole. B-mode
measurements require an instrument with exquisite sensitivity, tight control of
systematics, and wide frequency coverage to disentangle the primordial signal
from the Galactic foregrounds. BICEP Array represents the most recent stage of
the BK program, and comprises four BICEP3-class receivers observing at 30/40,
95, 150 and 220/270 GHz. The 30/40 GHz receiver will be deployed at the South
Pole during the 2019/2020 austral summer. After 3 full years of observations
with 30,000+ detectors, BICEP Array will measure primordial gravitational waves
to a precision $\sigma(r)$ between 0.002 and 0.004, depending on foreground
complexity and the degree of lensing removal. In this paper we give an overview
of the instrument, highlighting the design features in terms of cryogenics,
magnetic shielding, detectors and readout architecture as well as reporting on
the integration and tests that are ongoing with the first receiver at 30/40
GHz.
[5]
oai:arXiv.org:2002.05219 [pdf] - 2065429
Characterizing the Sensitivity of 40 GHz TES Bolometers for BICEP Array
Zhang, C.;
Ade, P. A. R.;
Ahmed, Z.;
Amiri, M.;
Barkats, D.;
Thakur, R. Basu;
Bischoff, C. A.;
Bock, J. J.;
Boenish, H.;
Bullock, E.;
Buza, V.;
Cheshire, J.;
Connors, J.;
Cornelison, J.;
Crumrine, M.;
Cukierman, A.;
Dierickx, M.;
Duband, L.;
Fatigoni, S.;
Filippini, J. P.;
Hall, G.;
Halpern, M.;
Harrison, S.;
Henderson, S.;
Hildebrandt, S. R.;
Hilton, G. C.;
Hui, H.;
Irwin, K. D.;
Kang, J.;
Karkare, K. S.;
Karpel, E.;
Kefeli, S.;
Kovac, J. M.;
Kuo, C. L.;
Lau, K.;
Megerian, K. G.;
Moncelsi, L.;
Namikawa, T.;
Nguyen, H. T.;
O'Brient, R.;
Palladino, S.;
Precup, N.;
Prouvé, T.;
Pryke, C.;
Racine, B.;
Reintsema, C. D.;
Richter, S.;
Schillaci, A.;
Schmitt, B.;
Schwarz, R.;
Sheehy, C. D.;
Soliman, A.;
Germaine, T. St.;
Steinbach, B.;
Sudiwala, R. V.;
Thompson, K. L.;
Tucker, C.;
Turner, A. D.;
Umiltà, C.;
Vieregg, A. G.;
Wandui, A.;
Weber, A. C.;
Wiebe, D. V.;
Willmert, J.;
Wu, W. L. K.;
Yang, E.;
Yoon, K. W.;
Young, E.;
Yu, C.
Submitted: 2020-02-12
The BICEP/Keck (BK) experiment aims to detect the imprint of primordial
gravitational waves in the Cosmic Microwave Background polarization, which
would be direct evidence of the inflation theory. While the tensor-to-scalar
ratio has been constrained to be r_0.05 < 0.06 at 95% c.l., further
improvements on this upper limit are hindered by polarized Galactic foreground
emissions and removal of gravitational lensing polarization. The 30/40 GHz
receiver of the BICEP Array (BA) will deploy at the end of 2019 and will
constrain the synchrotron foreground with unprecedented accuracy within the BK
sky patch. We will show the design of the 30/40 GHz detectors and test results
summarizing its performance. The low optical and atmospheric loading at these
frequencies requires our TES detectors to have low saturation power in order to
be photon-noise dominated. To realize the low thermal conductivity required
from a 250 mK base temperature, we developed new bolometer leg designs. We will
present the relevant measured detector parameters: G, Tc, Rn, Psat , and
spectral bands, and noise spectra. We achieved a per bolometer NEP including
all noise components of 2.07E-17 W/sqrt(Hz), including an anticipated photon
noise level 1.54E-17 W/sqrt(Hz).
[6]
oai:arXiv.org:2002.05197 [pdf] - 2093193
Optical characterization of the Keck Array and BICEP3 CMB Polarimeters
from 2016 to 2019
Collaboration, The BICEP/Keck;
:;
Germaine, T. St;
Ade, P. A. R.;
Ahmed, Z.;
Amiri, M.;
Barkats, D.;
Thakur, R. Basu;
Bischoff, C. A.;
Bock, J. J.;
Boenish, H.;
Bullock, E.;
Buza, V.;
Cheshire, J.;
Connors, J.;
Cornelison, J.;
Crumrine, M.;
Cukierman, A.;
Dierickx, M.;
Duband, L.;
Fatigoni, S.;
Filippini, J. P.;
Fliescher, S.;
Grayson, J. A.;
Hall, G.;
Halpern, M.;
Harrison, S.;
Hildebrandt, S. R.;
Hilton, G. C.;
Hui, H.;
Irwin, K. D.;
Kang, J.;
Karkare, K. S.;
Karpel, E.;
Kefeli, S.;
Kernasovskiy, S. A.;
Kovac, J. M.;
Kuo, C. L.;
Lau, K.;
Leitch, E. M.;
Megerian, K. G.;
Moncelsi, L.;
Namikawa, T.;
Netterfield, C. B.;
Nguyen, H. T.;
O'Brient, R.;
Ogburn, R. W.;
Palladino, S.;
Pryke, C.;
Racine, B.;
Reintsema, C. D.;
Richter, S.;
Schillaci, A.;
Schwarz, R.;
Sheehy, C. D.;
Soliman, A.;
Steinbach, B.;
Sudiwala, R. V.;
Thompson, K. L.;
Tolan, J. E.;
Tucker, C.;
Turner, A. D.;
Umilta, C.;
Vieregg, A. G.;
Wandui, A.;
Weber, A. C.;
Wiebe, D. V.;
Willmert, J.;
Wong, C. L.;
Wu, W. L. K.;
Yang, E.;
Yoon, K. W.;
Young, E.;
Yu, C.;
Zhang, C.
Submitted: 2020-02-12
The BICEP/Keck experiment (BK) is a series of small-aperture refracting
telescopes observing degree-scale Cosmic Microwave Background (CMB)
polarization from the South Pole in search of a primordial $B$-mode signature.
This $B$-mode signal arises from primordial gravitational waves interacting
with the CMB, and has amplitude parametrized by the tensor-to-scalar ratio $r$.
Since 2016, BICEP3 and the Keck Array have been observing with 4800 total
antenna-coupled transition-edge sensor detectors, with frequency bands spanning
95, 150, 220, and 270 GHz. Here we present the optical performance of these
receivers from 2016 to 2019, including far-field beams measured in situ with an
improved chopped thermal source and instrument spectral response measured with
a field-deployable Fourier Transform Spectrometer. As a pair differencing
experiment, an important systematic that must be controlled is the differential
beam response between the co-located, orthogonally polarized detectors. We
generate per-detector far-field beam maps and the corresponding differential
beam mismatch that is used to estimate the temperature-to-polarization leakage
in our CMB maps and to give feedback on detector and optics fabrication. The
differential beam parameters presented here were estimated using improved
low-level beam map analysis techniques, including efficient removal of
non-Gaussian noise as well as improved spatial masking. These techniques help
minimize systematic uncertainty in the beam analysis, with the goal of
constraining the bias on $r$ induced by temperature-to-polarization leakage to
be subdominant to the statistical uncertainty. This is essential as we progress
to higher detector counts in the next generation of CMB experiments.
[7]
oai:arXiv.org:1909.01305 [pdf] - 2034407
Microwave multiplexing on the Keck Array
Cukierman, Ari;
Ahmed, Zeeshan;
Henderson, Shawn;
Young, Edward;
Yu, Cyndia;
Barkats, Denis;
Brown, David;
Chaudhuri, Saptarshi;
Cornelison, James;
D'Ewart, John M.;
Dierickx, Marion;
Dober, Bradley J.;
Dusatko, John;
Fatigoni, Sofia;
Filippini, Jeff P.;
Frisch, Josef C.;
Haller, Gunther;
Halpern, Mark;
Hilton, Gene C.;
Hubmayr, Johannes;
Irwin, Kent D.;
Karkare, Kirit S.;
Karpel, Ethan;
Kernasovskiy, Sarah A.;
Kovac, John M.;
Kovacs, Attila;
Kuenstner, Stephen E.;
Kuo, Chao-Lin;
Li, Dale;
Mates, John A. B.;
Smith, Stephen;
Germaine, Tyler St.;
Ullom, Joel N.;
Vale, Leila R.;
Van Winkle, Daniel D.;
Vasquez, Jesus;
Willmert, Justin;
Zeng, Lingzhen;
Ade, P. A. R.;
Amiri, M.;
Thakur, R. Basu;
Bischoff, C. A.;
Bock, J. J.;
Boenish, H.;
Bullock, E.;
Buza, V.;
Cheshire, J.;
Connors, J.;
Crumrine, M.;
Duband, L.;
Hall, G.;
Harrison, S.;
Hildebrandt, S. R.;
Hui, H.;
Kang, J.;
Kefeli, S.;
Lau, K.;
Megerian, K. G.;
Moncelsi, L.;
Namikawa, T.;
Nguyen, H. T.;
O'Brient, R.;
Palladino, S.;
Pryke, C.;
Racine, B.;
Reintsema, C. D.;
Richter, S.;
Schillaci, A.;
Schwarz, R.;
Sheehy, C. D.;
Soliman, A.;
Steinbach, B.;
Sudiwala, R. V.;
Thompson, K. L.;
Tucker, C.;
Turner, A. D.;
Umilta, C.;
Vieregg, A. G.;
Wandui, A.;
Weber, A. C.;
Wiebe, D. V.;
Wu, W. L. K.;
Yang, H.;
Yoon, K. W.;
Zhang, C.
Submitted: 2019-09-03, last modified: 2020-01-17
We describe an on-sky demonstration of a microwave-multiplexing readout
system in one of the receivers of the Keck Array, a polarimetry experiment
observing the cosmic microwave background at the South Pole. During the austral
summer of 2018-2019, we replaced the time-division multiplexing readout system
with microwave-multiplexing components including superconducting microwave
resonators coupled to radio-frequency superconducting quantum interference
devices at the sub-Kelvin focal plane, coaxial-cable plumbing and amplification
between room temperature and the cold stages, and a SLAC Microresonator Radio
Frequency system for the warm electronics. In the range 5-6 GHz, a single
coaxial cable reads out 528 channels. The readout system is coupled to
transition-edge sensors, which are in turn coupled to 150-GHz slot-dipole
phased-array antennas. Observations began in April 2019, and we report here on
an initial characterization of the system performance.
[8]
oai:arXiv.org:1911.08047 [pdf] - 2000343
Particle Physics with the Cosmic Microwave Background with SPT-3G
Avva, J. S.;
Ade, P. A. R.;
Ahmed, Z.;
Anderson, A. J.;
Aylor, K.;
Thakur, R. Basu;
Bender, A. N.;
Benson, B. A.;
Bleem, L. E.;
Bocquet, S.;
Bryant, L.;
Carlstrom, J. E.;
Carter, F. W.;
Cecil, T. W.;
Chang, C. L.;
Crawford, T. M.;
Cukierman, A.;
de Haan, T.;
Ding, J.;
Dobbs, M. A.;
Dodelson, S.;
Dutcher, D.;
Everett, W.;
Ferguson, K. R.;
Foster, A.;
Gallicchio, J.;
Gambrel, A. E.;
Gardner, R. W.;
Groh, J. C.;
Guns, S.;
Halverson, N. W.;
Harke-Hosemann, A. H.;
Harrington, N. L.;
Henning, J. W.;
Holder, G. P.;
Holzapfel, W. L.;
Howe, D.;
Huang, N.;
Irwin, K. D.;
Jeong, O. B.;
Jonas, M.;
Jones, A.;
Khaire, T. S.;
Knox, L.;
Kofman, A. M.;
Korman, M.;
Kubik, D. L.;
Kuhlmann, S.;
Kuo, C. -L.;
Lee, A. T.;
Lowitz, A. E.;
Meyer, S. S.;
Michalik, D.;
Montgomery, J.;
Nadolski, A.;
Natoli, T.;
Nguyen, H.;
Noble, G. I.;
Novosad, V.;
Padin, S.;
Pan, Z.;
Paschos, P.;
Pearson, J.;
Posada, C. M.;
Quan, W.;
Raghunathan, S.;
Rahlin, A.;
Reichardt, C. L.;
Riebel, D.;
Ruhl, J. E.;
Sayre, J. T.;
Shirokoff, E.;
Smecher, G.;
Sobrin, J. A.;
Stark, A. A.;
Stephen, J.;
Story, K. T.;
Suzuki, A.;
Thompson, K. L.;
Tucker, C.;
Vanderlinde, K.;
Vieira, J. D.;
Wang, G.;
Whitehorn, N.;
Wu, W. L. K.;
Yefremenko, V.;
Yoon, K. W.;
Young, M. R.
Submitted: 2019-11-18
The cosmic microwave background (CMB) encodes information about the content
and evolution of the universe. The presence of light, weakly interacting
particles impacts the expansion history of the early universe, which alters the
temperature and polarization anisotropies of the CMB. In this way, current
measurements of the CMB place interesting constraints on the neutrino energy
density and mass, as well as on the abundance of other possible light
relativistic particle species. We present the status of an on-going 1500 sq.
deg. survey with the SPT-3G receiver, a new mm-wavelength camera on the 10-m
diameter South Pole Telescope (SPT). The SPT-3G camera consists of 16,000
superconducting transition edge sensors, a 10x increase over the previous
generation camera, which allows it to map the CMB with an unprecedented
combination of sensitivity and angular resolution. We highlight projected
constraints on the abundance of sterile neutrinos and the sum of the neutrino
masses for the SPT-3G survey, which could help determine the neutrino mass
hierarchy.
[9]
oai:arXiv.org:1909.02100 [pdf] - 1956006
Superconducting On-chip Fourier Transform Spectrometer
Submitted: 2019-09-04
Kinetic inductance in thin film superconductors has been used as the basis
for low-temperature, low-noise photon detectors. In particular thin films such
as NbTiN, TiN, NbN, the kinetic inductance effect is strongly non-linear in the
applied current, which can be utilized to realize novel devices. We present
results from transmission lines made with these materials, where DC (current)
control is used to modulate the phase velocity thereby enabling an on-chip
spectrometer. The utility of such compact spectrometers are discussed, along
with their natural connection with parametric amplifiers.
[11]
oai:arXiv.org:1907.12602 [pdf] - 1953685
Stability of Gluonic Systems with Multiple Soft Interactions
Submitted: 2019-07-29
In this paper, we investigate the stability properties of soft gluons in
SIBYLL 2.1 with reference to its original version 1.7 that corresponds to
hadronic hard interactions. In order to investigate the stability structures,
we classify the regions of the gluon density fluctuations in its double leading
logarithmic approximation and its equivalent description as the fractional
power law. In the parameter space of initial transverse momentum $Q$ and QCD
renormalization scale $L$ that correspond to extensive air showers of cosmic
rays, we have categorized the surface of parameters over which the proton is
stable. We further discuss the nature of local and global correlations and
stability properties where the concerning statistical basis yields a stable
system or undergoes a geometric phase transition. Finally, we give a
phenomenological understanding towards the stability of soft interactions,
Pomeron particle productions in minijet model, string fragmentation and verify
our result corresponding to the experiments - CDF, P238, UAS, GEUS and UA4
collaborations.
[12]
oai:arXiv.org:1907.11976 [pdf] - 2025648
Performance of Al-Mn Transition-Edge Sensor Bolometers in SPT-3G
Anderson, A. J.;
Ade, P. A. R.;
Ahmed, Z.;
Avva, J. S.;
Barry, P. S.;
Thakur, R. Basu;
Bender, A. N.;
Benson, B. A.;
Bryant, L.;
Byrum, K.;
Carlstrom, J. E.;
Carter, F. W.;
Cecil, T. W.;
Chang, C. L.;
Cho, H. -M.;
Cliche, J. F.;
Cukierman, A.;
de Haan, T.;
Denison, E. V.;
Ding, J.;
Dobbs, M. A.;
Dutcher, D.;
Everett, W.;
Ferguson, K. R.;
Foster, A.;
Fu, J.;
Gallicchio, J.;
Gambrel, A. E.;
Gardner, R. W.;
Gilbert, A.;
Groh, J. C.;
Guns, S.;
Guyser, R.;
Halverson, N. W.;
Harke-Hosemann, A. H.;
Harrington, N. L.;
Henning, J. W.;
Hilton, G. C.;
Holzapfel, W. L.;
Howe, D.;
Huang, N.;
Irwin, K. D.;
Jeong, O. B.;
Jonas, M.;
Jones, A.;
Khaire, T. S.;
Kofman, A. M.;
Korman, M.;
Kubik, D. L.;
Kuhlmann, S.;
Kuo, C. -L.;
Lee, A. T.;
Leitch, E. M.;
Lowitz, A. E.;
Meyer, S. S.;
Michalik, D.;
Montgomery, J.;
Nadolski, A.;
Natoli, T.;
Nguyen, H.;
Noble, G. I.;
Novosad, V.;
Padin, S.;
Pan, Z.;
Paschos, P.;
Pearson, J.;
Posada, C. M.;
Quan, W.;
Rahlin, A.;
Riebel, D.;
Ruhl, J. E.;
Sayre, J. T.;
Shirokoff, E.;
Smecher, G.;
Sobrin, J. A.;
Stark, A. A.;
Stephen, J.;
Story, K. T.;
Suzuki, A.;
Thompson, K. L.;
Tucker, C.;
Vale, L. R.;
Vanderlinde, K.;
Vieira, J. D.;
Wang, G.;
Whitehorn, N.;
Yefremenko, V.;
Yoon, K. W.;
Young, M. R.
Submitted: 2019-07-27
SPT-3G is a polarization-sensitive receiver, installed on the South Pole
Telescope, that measures the anisotropy of the cosmic microwave background
(CMB) from degree to arcminute scales. The receiver consists of ten
150~mm-diameter detector wafers, containing a total of 16,000 transition-edge
sensor (TES) bolometers observing at 95, 150, and 220 GHz. During the 2018-2019
austral summer, one of these detector wafers was replaced by a new wafer
fabricated with Al-Mn TESs instead of the Ti/Au design originally deployed for
SPT-3G. We present the results of in-lab characterization and on-sky
performance of this Al-Mn wafer, including electrical and thermal properties,
optical efficiency measurements, and noise-equivalent temperature. In addition,
we discuss and account for several calibration-related systematic errors that
affect measurements made using frequency-domain multiplexing readout
electronics.
[13]
oai:arXiv.org:1907.10947 [pdf] - 2025643
On-sky performance of the SPT-3G frequency-domain multiplexed readout
Bender, A. N.;
Anderson, A. J.;
Avva, J. S.;
Ade, P. A. R.;
Ahmed, Z.;
Barry, P. S.;
Thakur, R. Basu;
Benson, B. A.;
Bryant, L.;
Byrum, K.;
Carlstrom, J. E.;
Carter, F. W.;
Cecil, T. W.;
Chang, C. L.;
Cho, H. -M.;
Cliche, J. F.;
Cukierman, A.;
de Haan, T.;
Denison, E. V.;
Ding, J.;
Dobbs, M. A.;
Dutcher, D.;
Everett, W.;
Ferguson, K. R.;
Foster, A.;
Fu, J.;
Gallicchio, J.;
Gambrel, A. E.;
Gardner, R. W.;
Gilbert, A.;
Groh, J. C.;
Guns, S.;
Guyser, R.;
Halverson, N. W.;
Harke-Hosemann, A. H.;
Harrington, N. L.;
Henning, J. W.;
Hilton, G. C.;
Holzapfel, W. L.;
Howe, D.;
Huang, N.;
Irwin, K. D.;
Jeong, O. B.;
Jonas, M.;
Jones, A.;
Khaire, T. S.;
Kofman, A. M.;
Korman, M.;
Kubik, D. L.;
Kuhlmann, S.;
Kuo, C. -L.;
Lee, A. T.;
Leitch, E. M.;
Lowitz, A. E.;
Meyer, S. S.;
Michalik, D.;
Montgomery, J.;
Nadolski, A.;
Natoli, T.;
Nguyen, H.;
Noble, G. I.;
Novosad, V.;
Padin, S.;
Pan, Z.;
Paschos, P.;
Pearson, J.;
Posada, C. M.;
Quan, W.;
Rahlin, A.;
Riebel, D.;
Ruhl, J. E.;
Sayre, J. T.;
Shirokoff, E.;
Smecher, G.;
Sobrin, J. A.;
Stark, A. A.;
Stephen, J.;
Story, K. T.;
Suzuki, A.;
Thompson, K. L.;
Tucker, C.;
Vale, L. R.;
Vanderlinde, K.;
Vieira, J. D.;
Wang, G.;
Whitehorn, N.;
Yefremenko, V.;
Yoon, K. W.;
Young, M. R.
Submitted: 2019-07-25
Frequency-domain multiplexing (fMux) is an established technique for the
readout of large arrays of transition edge sensor (TES) bolometers. Each TES in
a multiplexing module has a unique AC voltage bias that is selected by a
resonant filter. This scheme enables the operation and readout of multiple
bolometers on a single pair of wires, reducing thermal loading onto sub-Kelvin
stages. The current receiver on the South Pole Telescope, SPT-3G, uses a 68x
fMux system to operate its large-format camera of $\sim$16,000 TES bolometers.
We present here the successful implementation and performance of the SPT-3G
readout as measured on-sky. Characterization of the noise reveals a median
pair-differenced 1/f knee frequency of 33 mHz, indicating that low-frequency
noise in the readout will not limit SPT-3G's measurements of sky power on large
angular scales. Measurements also show that the median readout white noise
level in each of the SPT-3G observing bands is below the expectation for photon
noise, demonstrating that SPT-3G is operating in the photon-noise-dominated
regime.
[15]
oai:arXiv.org:1806.06872 [pdf] - 1916736
Observationally inferred dark matter phase-space distribution and direct
detection experiments
Submitted: 2018-06-18, last modified: 2019-07-04
We present a detailed analysis of the effect of an observationally determined
dark matter (DM) velocity distribution function (VDF) of the Milky Way (MW) on
DM direct detection rates. We go beyond local kinematic tracers and use
rotation curve data up to 200 kpc to construct a MW mass model and
self-consistently determine the local phase-space distribution of DM. This
approach mitigates any incomplete understanding of local dark matter-visible
matter degeneracies that can affect the determination of the VDF. Comparing
with the oft used Standard Halo Model (SHM), which assumes an isothermal VDF,
we look at how the tail of the empirically determined VDF alters our
interpretation of the present direct detection WIMP DM cross section exclusion
limits. While previous studies have suggested a very large difference (of more
than an order of magnitude) in the bounds at low DM masses, we show that
accounting for the detector response at low threshold energies, the difference
is still significant although less extreme. The change in the number of signal
events, when using the empirically determined DM VDF in contrast to the SHM
VDF, is most prominent for low DM masses for which the shape of the recoil
energy spectrum depends sensitively on the detector threshold energy as well as
detector response near the threshold. We demonstrate that these trends carry
over to the respective DM exclusion limits, modulo detailed understanding of
the experimental backgrounds. With the unprecedented precision of astrometric
data in the GAIA era, use of observationally determined DM phase-space will
become a critical and necessary ingredient for DM searches. We provide an
accurate fit to the current best observationally determined DM VDF (and
self-consistent local DM density) for use in analyzing current DM direct
detection data by the experimental community.
[16]
oai:arXiv.org:1905.07399 [pdf] - 1953523
A Compact Millimeter-Wavelength Fourier-Transform Spectrometer
Submitted: 2019-05-17
We have constructed a Fourier-transform spectrometer (FTS) operating between
50 and 330 GHz with minimum volume (355 x260 x64 mm) and weight (13 lbs) while
maximizing optical throughput (100 $\mathrm{mm}^2$ sr) and optimizing the
spectral resolution (4 GHz). This FTS is designed as a polarizing
Martin-Puplett interferometer with unobstructed input and output in which both
input polarizations undergo interference. The instrument construction is simple
with mirrors milled on the box walls and one motorized stage as the single
moving element. We characterize the performance of the FTS, compare the
measurements to an optical simulation, and discuss features that relate to
details of the FTS design. The simulation is also used to determine the
tolerance of optical alignments for the required specifications. We detail the
FTS mechanical design and provide the control software as well as the analysis
code online.
[17]
oai:arXiv.org:1903.04218 [pdf] - 1873787
Spectral Distortions of the CMB as a Probe of Inflation, Recombination,
Structure Formation and Particle Physics
Chluba, J.;
Kogut, A.;
Patil, S. P.;
Abitbol, M. H.;
Aghanim, N.;
Ali-Haimoud, Y.;
Amin, M. A.;
Aumont, J.;
Bartolo, N.;
Basu, K.;
Battistelli, E. S.;
Battye, R.;
Baumann, D.;
Ben-Dayan, I.;
Bolliet, B.;
Bond, J. R.;
Bouchet, F. R.;
Burgess, C. P.;
Burigana, C.;
Byrnes, C. T.;
Cabass, G.;
Chuss, D. T.;
Clesse, S.;
Cole, P. S.;
Dai, L.;
de Bernardis, P.;
Delabrouille, J.;
Desjacques, V.;
de Zotti, G.;
Diacoumis, J. A. D.;
Dimastrogiovanni, E.;
Di Valentino, E.;
Dunkley, J.;
Durrer, R.;
Dvorkin, C.;
Ellis, J.;
Eriksen, H. K.;
Fasiello, M.;
Fixsen, D.;
Finelli, F.;
Flauger, R.;
Galli, S.;
Garcia-Bellido, J.;
Gervasi, M.;
Gluscevic, V.;
Grin, D.;
Hart, L.;
Hernandez-Monteagudo, C.;
Hill, J. C.;
Jeong, D.;
Johnson, B. R.;
Lagache, G.;
Lee, E.;
Lewis, A.;
Liguori, M.;
Kamionkowski, M.;
Khatri, R.;
Kohri, K.;
Komatsu, E.;
Kunze, K. E.;
Mangilli, A.;
Masi, S.;
Mather, J.;
Matarrese, S.;
Miville-Deschenes, M. A.;
Montaruli, T.;
Munchmeyer, M.;
Mukherjee, S.;
Nakama, T.;
Nati, F.;
Ota, A.;
Page, L. A.;
Pajer, E.;
Poulin, V.;
Ravenni, A.;
Reichardt, C.;
Remazeilles, M.;
Rotti, A.;
Rubino-Martin, J. A.;
Sarkar, A.;
Sarkar, S.;
Savini, G.;
Scott, D.;
Serpico, P. D.;
Silk, J.;
Souradeep, T.;
Spergel, D. N.;
Starobinsky, A. A.;
Subrahmanyan, R.;
Sunyaev, R. A.;
Switzer, E.;
Tartari, A.;
Tashiro, H.;
Thakur, R. Basu;
Trombetti, T.;
Wallisch, B.;
Wandelt, B. D.;
Wehus, I. K.;
Wollack, E. J.;
Zaldarriaga, M.;
Zannoni, M.
Submitted: 2019-03-11, last modified: 2019-04-25
Following the pioneering observations with COBE in the early 1990s, studies
of the cosmic microwave background (CMB) have focused on temperature and
polarization anisotropies. CMB spectral distortions - tiny departures of the
CMB energy spectrum from that of a perfect blackbody - provide a second,
independent probe of fundamental physics, with a reach deep into the primordial
Universe. The theoretical foundation of spectral distortions has seen major
advances in recent years, which highlight the immense potential of this
emerging field. Spectral distortions probe a fundamental property of the
Universe - its thermal history - thereby providing additional insight into
processes within the cosmological standard model (CSM) as well as new physics
beyond. Spectral distortions are an important tool for understanding inflation
and the nature of dark matter. They shed new light on the physics of
recombination and reionization, both prominent stages in the evolution of our
Universe, and furnish critical information on baryonic feedback processes, in
addition to probing primordial correlation functions at scales inaccessible to
other tracers. In principle the range of signals is vast: many orders of
magnitude of discovery space could be explored by detailed observations of the
CMB energy spectrum. Several CSM signals are predicted and provide clear
experimental targets, some of which are already observable with present-day
technology. Confirmation of these signals would extend the reach of the CSM by
orders of magnitude in physical scale as the Universe evolves from the initial
stages to its present form. The absence of these signals would pose a huge
theoretical challenge, immediately pointing to new physics.
[18]
oai:arXiv.org:1903.11744 [pdf] - 1857808
Tomography of the Cosmic Dawn and Reionization Eras with Multiple
Tracers
Chang, Tzu-Ching;
Beane, Angus;
Dore, Olivier;
Lidz, Adam;
Mas-Ribas, Lluis;
Sun, Guochao;
Alvarez, Marcelo;
Thakur, Ritoban Basu;
Berger, Philippe;
Bethermin, Matthieu;
Bock, Jamie;
Bradford, Charles M.;
Breysse, Patrick;
Burgarella, Denis;
Charmandaris, Vassilis;
Cheng, Yun-Ting;
Cleary, Kieran;
Cooray, Asantha;
Crites, Abigail;
Ewall-Wice, Aaron;
Fan, Xiaohui;
Finkelstein, Steve;
Furlanetto, Steve;
Hewitt, Jacqueline;
Hunacek, Jonathon;
Korngut, Phil;
Kovetz, Ely;
Hallinan, Gregg;
Heneka, Caroline;
Lagache, Guilaine;
Lawrence, Charles;
Lazio, Joseph;
Liu, Adrian;
Marrone, Dan;
Parsons, Aaron;
Readhead, Anthony;
Rhodes, Jason;
Riechers, Dominik;
Seiffert, Michael;
Stacey, Gordon;
Visbal, Eli;
Wu, Hao-Yi;
Zemcov, Michael;
Zheng, Zheng
Submitted: 2019-03-27
The Cosmic Dawn and Reionization epochs remain a fundamental but challenging
frontier of astrophysics and cosmology. We advocate a large-scale, multi-tracer
approach to develop a comprehensive understanding of the physics that led to
the formation and evolution of the first stars and galaxies. We highlight the
line intensity mapping technique to trace the multi-phase reionization topology
on large scales, and measure reionization history in detail. Besides 21cm, we
advocate for Lya tomography mapping during the epoch of Wouthuysen-Field
coupling as an additional probe of the cosmic dawn era.
[19]
oai:arXiv.org:1902.09640 [pdf] - 1838469
Design and Bolometer Characterization of the SPT-3G First-year Focal
Plane
Everett, W.;
Ade, P. A. R.;
Ahmed, Z.;
Anderson, A. J.;
Austermann, J. E.;
Avva, J. S.;
Thakur, R. Basu;
Bender, A. N.;
Benson, B. A.;
Carlstrom, J. E.;
Carter, F. W.;
Cecil, T.;
Chang, C. L.;
Cliche, J. F.;
Cukierman, A.;
Denison, E. V.;
de Haan, T.;
Ding, J.;
Dobbs, M. A.;
Dutcher, D.;
Foster, A.;
Gannon, R. N.;
Gilbert, A.;
Groh, J. C.;
Halverson, N. W.;
Harke-Hosemann, A. H.;
Harrington, N. L.;
Henning, J. W.;
Hilton, G. C.;
Holzapfel, W. L.;
Huang, N.;
Irwin, K. D.;
Jeong, O. B.;
Jonas, M.;
Khaire, T.;
Kofman, A. M.;
Korman, M.;
Kubik, D.;
Kuhlmann, S.;
Kuo, C. L.;
Lee, A. T.;
Lowitz, A. E.;
Meyer, S. S.;
Michalik, D.;
Montgomery, J.;
Nadolski, A.;
Natoli, T.;
Nguyen, H.;
Noble, G. I.;
Novosad, V.;
Padin, S.;
Pan, Z.;
Pearson, J.;
Posada, C. M.;
Rahlin, A.;
Ruhl, J. E.;
Saunders, L. J.;
Sayre, J. T.;
Shirley, I.;
Shirokoff, E.;
Smecher, G.;
Sobrin, J. A.;
Stark, A. A.;
Story, K. T.;
Suzuki, A.;
Tang, Q. Y.;
Thompson, K. L.;
Tucker, C.;
Vale, L. R.;
Vanderlinde, K.;
Vieira, J. D.;
Wang, G.;
Whitehorn, N.;
Yefremenko, V.;
Yoon, K. W.;
Young, M. R.
Submitted: 2019-02-25
During the austral summer of 2016-17, the third-generation camera, SPT-3G,
was installed on the South Pole Telescope, increasing the detector count in the
focal plane by an order of magnitude relative to the previous generation.
Designed to map the polarization of the cosmic microwave background, SPT-3G
contains ten 6-in-hexagonal modules of detectors, each with 269 trichroic and
dual-polarization pixels, read out using 68x frequency-domain multiplexing.
Here we discuss design, assembly, and layout of the modules, as well as early
performance characterization of the first-year array, including yield and
detector properties.
[20]
oai:arXiv.org:1809.00033 [pdf] - 1743941
Characterization and performance of the second-year SPT-3G focal plane
Dutcher, D.;
Ade, P. A. R.;
Ahmed, Z.;
Anderson, A. J.;
Avva, J. S.;
Thakur, R. Basu;
Bender, A. N.;
Benson, B. A.;
Carlstrom, J. E.;
Carter, F. W.;
Cecil, T. W.;
Chang, C. L.;
Cliche, J. F.;
Cukierman, A.;
de Haan, T.;
Ding, J.;
Dobbs, M. A.;
Everett, W.;
Foster, A.;
Gallicchio, J.;
Gilbert, A.;
Groh, J. C.;
Guns, S. T.;
Halverson, N. W.;
Harke-Hosemann, A. H.;
Harrington, N. L.;
Henning, J. W.;
Holzapfel, W. L.;
Huang, N.;
Irwin, K. D.;
Jeong, O. B.;
Jonas, M.;
Khaire, T. S.;
Kofman, A. M.;
Korman, M.;
Kubik, D. L.;
Kuhlmann, S.;
Kuo, C. -L.;
Lee, A. T.;
Lowitz, A. E.;
Meyer, S. S.;
Michalik, D.;
Montgomery, J.;
Nadolski, A.;
Natoli, T.;
Nguyen, H.;
Noble, G. I.;
Novosad, V.;
Padin, S.;
Pan, Z.;
Pearson, J.;
Posada, C. M.;
Quan, W.;
Rahlin, A.;
Ruhl, J. E.;
Sayre, J. T.;
Shirokoff, E.;
Smecher, G.;
Sobrin, J. A.;
Stark, A. A.;
Story, K. T.;
Suzuki, A.;
Thompson, K. L.;
Tucker, C.;
Vanderlinde, K.;
Vieira, J. D.;
Wang, G.;
Whitehorn, N.;
Yefremenko, V.;
Yoon, K. W.;
Young, M. R.
Submitted: 2018-08-31
The third-generation instrument for the 10-meter South Pole Telescope,
SPT-3G, was first installed in January 2017. In addition to completely new
cryostats, secondary telescope optics, and readout electronics, the number of
detectors in the focal plane has increased by an order of magnitude from
previous instruments to ~16,000. The SPT-3G focal plane consists of ten
detector modules, each with an array of 269 trichroic, polarization-sensitive
pixels on a six-inch silicon wafer. Within each pixel is a broadband,
dual-polarization sinuous antenna; the signal from each orthogonal linear
polarization is divided into three frequency bands centered at 95, 150, and 220
GHz by in-line lumped element filters and transmitted via superconducting
microstrip to Ti/Au transition-edge sensor (TES) bolometers. Properties of the
TES film, microstrip filters, and bolometer island must be tightly controlled
to achieve optimal performance. For the second year of SPT-3G operation, we
have replaced all ten wafers in the focal plane with new detector arrays tuned
to increase mapping speed and improve overall performance. Here we discuss the
TES superconducting transition temperature and normal resistance, detector
saturation power, bandpasses, optical efficiency, and full array yield for the
2018 focal plane.
[21]
oai:arXiv.org:1809.00036 [pdf] - 1743942
Year two instrument status of the SPT-3G cosmic microwave background
receiver
Bender, A. N.;
Ade, P. A. R.;
Ahmed, Z.;
Anderson, A. J.;
Avva, J. S.;
Aylor, K.;
Barry, P. S.;
Thakur, R. Basu;
Benson, B. A.;
Bleem, L. S.;
Bocquet, S.;
Byrum, K.;
Carlstrom, J. E.;
Carter, F. W.;
Cecil, T. W.;
Chang, C. L.;
Cho, H. -M.;
Cliche, J. F.;
Crawford, T. M.;
Cukierman, A.;
de Haan, T.;
Denison, E. V.;
Ding, J.;
Dobbs, M. A.;
Dodelson, S.;
Dutcher, D.;
Everett, W.;
Foster, A.;
Gallicchio, J.;
Gilbert, A.;
Groh, J. C.;
Guns, S. T.;
Halverson, N. W.;
Harke-Hosemann, A. H.;
Harrington, N. L.;
Henning, J. W.;
Hilton, G. C.;
Holder, G. P.;
Holzapfel, W. L.;
Huang, N.;
Irwin, K. D.;
Jeong, O. B.;
Jonas, M.;
Jones, A.;
Khaire, T. S.;
Knox, L.;
Kofman, A. M.;
Korman, M.;
Kubik, D. L.;
Kuhlmann, S.;
Kuo, C. -L.;
Lee, A. T.;
Leitch, E. M.;
Lowitz, A. E.;
Meyer, S. S.;
Michalik, D.;
Montgomery, J.;
Nadolski, A.;
Natoli, T.;
Nguyen, H.;
Noble, G. I.;
Novosad, V.;
Padin, S.;
Pan, Z.;
Pearson, J.;
Posada, C. M.;
Quan, W.;
Raghunathan, S.;
Rahlin, A.;
Reichardt, C. L.;
Ruhl, J. E.;
Sayre, J. T.;
Shirokoff, E.;
Smecher, G.;
Sobrin, J. A.;
Stark, A. A.;
Story, K. T.;
Suzuki, A.;
Thompson, K. L.;
Tucker, C.;
Vale, L. R.;
Vanderlinde, K.;
Vieira, J. D.;
Wang, G.;
Whitehorn, N.;
Wu, W. L. K.;
Yefremenko, V.;
Yoon, K. W.;
Young, M. R.
Submitted: 2018-08-31
The South Pole Telescope (SPT) is a millimeter-wavelength telescope designed
for high-precision measurements of the cosmic microwave background (CMB). The
SPT measures both the temperature and polarization of the CMB with a large
aperture, resulting in high resolution maps sensitive to signals across a wide
range of angular scales on the sky. With these data, the SPT has the potential
to make a broad range of cosmological measurements. These include constraining
the effect of massive neutrinos on large-scale structure formation as well as
cleaning galactic and cosmological foregrounds from CMB polarization data in
future searches for inflationary gravitational waves. The SPT began observing
in January 2017 with a new receiver (SPT-3G) containing $\sim$16,000
polarization-sensitive transition-edge sensor bolometers. Several key
technology developments have enabled this large-format focal plane, including
advances in detectors, readout electronics, and large millimeter-wavelength
optics. We discuss the implementation of these technologies in the SPT-3G
receiver as well as the challenges they presented. In late 2017 the
implementations of all three of these technologies were modified to optimize
total performance. Here, we present the current instrument status of the SPT-3G
receiver.
[22]
oai:arXiv.org:1809.00032 [pdf] - 1743940
Design and characterization of the SPT-3G receiver
Sobrin, J. A.;
Ade, P. A. R.;
Ahmed, Z.;
Anderson, A. J.;
Avva, J. S.;
Thakur, R. Basu;
Bender, A. N.;
Benson, B. A.;
Carlstrom, J. E.;
Carter, F. W.;
Cecil, T. W.;
Chang, C. L.;
Cliche, J. F.;
Cukierman, A.;
de Haan, T.;
Ding, J.;
Dobbs, M. A.;
Dutcher, D.;
Everett, W.;
Foster, A.;
Gallichio, J.;
Gilbert, A.;
Groh, J. C.;
Guns, S. T.;
Halverson, N. W.;
Harke-Hosemann, A. H.;
Harrington, N. L.;
Henning, J. W.;
Holzapfel, W. L.;
Huang, N.;
Irwin, K. D.;
Jeong, O. B.;
Jonas, M.;
Khaire, T. S.;
Kofman, A. M.;
Korman, M.;
Kubik, D. L.;
Kuhlmann, S.;
Kuo, C. L.;
Lee, A. T.;
Lowitz, A. E.;
Meyer, S. S.;
Michalik, D.;
Montgomery, J.;
Nadolski, A.;
Natoli, T.;
Nguyen, H.;
Noble, G. I.;
Novosad, V.;
Padin, S.;
Pan, Z.;
Pearson, J.;
Posada, C. M.;
Quan, W.;
Rahlin, A.;
Ruhl, J. E.;
Sayre, J. T.;
Shirokoff, E.;
Smecher, G.;
Stark, A. A.;
Story, K. T.;
Suzuki, A.;
Thompson, K. L.;
Tucker, C.;
Vanderlinde, K.;
Vieira, J. D.;
Wang, G.;
Whitehorn, N.;
Yefremenko, V.;
Yoon, K. W.;
Young, M.
Submitted: 2018-08-31
The SPT-3G receiver was commissioned in early 2017 on the 10-meter South Pole
Telescope (SPT) to map anisotropies in the cosmic microwave background (CMB).
New optics, detector, and readout technologies have yielded a multichroic,
high-resolution, low-noise camera with impressive throughput and sensitivity,
offering the potential to improve our understanding of inflationary physics,
astroparticle physics, and growth of structure. We highlight several key
features and design principles of the new receiver, and summarize its
performance to date.
[23]
oai:arXiv.org:1809.00030 [pdf] - 1848536
Broadband anti-reflective coatings for cosmic microwave background
experiments
Nadolski, A.;
Kofman, A. M.;
Vieira, J. D.;
Ade, P. A. R.;
Ahmed, Z.;
Anderson, A. J.;
Avva, J. S.;
Thakur, R. Basu;
Bender, A. N.;
Benson, B. A.;
Carlstrom, J. E.;
Carter, F. W.;
Cecil, T. W.;
Chang, C. L.;
Cliche, J. F.;
Cukierman, A.;
de Haan, T.;
Ding, J.;
Dobbs, M. A.;
Dutcher, D.;
Everett, W.;
Foster, A.;
Fu, J.;
Gallicchio, J.;
Gilbert, A.;
Groh, J. C.;
Guns, S. T.;
Guyser, R.;
Halverson, N. W.;
Harke-Hosemann, A. H.;
Harrington, N. L.;
Henning, J. W.;
Holzapfel, W. L.;
Huang, N.;
Irwin, K. D.;
Jeong, O. B.;
Jonas, M.;
Jones, A.;
Khaire, T. S.;
Korman, M.;
Kubik, D. L.;
Kuhlmann, S.;
Kuo, C. -L.;
Lee, A. T.;
Lowitz, A. E.;
Meyer, S. S.;
Michalik, D.;
Montgomery, J.;
Natoli, T.;
Nguyen, H.;
Noble, G. I.;
Novosad, V.;
Padin, S.;
Pan, Z.;
Pearson, J.;
Posada, C. M.;
Quan, W.;
Rahlin, A.;
Ruhl, J. E.;
Sayre, J. T.;
Shirokoff, E.;
Smecher, G.;
Sobrin, J. A.;
Stark, A. A.;
Story, K. T.;
Suzuki, A.;
Thompson, K. L.;
Tucker, C.;
Vanderlinde, K.;
Wang, G.;
Whitehorn, N.;
Yefremenko, V.;
Yoon, K. W.;
Young, M. R.
Submitted: 2018-08-31
The desire for higher sensitivity has driven ground-based cosmic microwave
background (CMB) experiments to employ ever larger focal planes, which in turn
require larger reimaging optics. Practical limits to the maximum size of these
optics motivates the development of quasi-optically-coupled (lenslet-coupled),
multi-chroic detectors. These detectors can be sensitive across a broader
bandwidth compared to waveguide-coupled detectors. However, the increase in
bandwidth comes at a cost: the lenses (up to $\sim$700 mm diameter) and
lenslets ($\sim$5 mm diameter, hemispherical lenses on the focal plane) used in
these systems are made from high-refractive-index materials (such as silicon or
amorphous aluminum oxide) that reflect nearly a third of the incident
radiation. In order to maximize the faint CMB signal that reaches the
detectors, the lenses and lenslets must be coated with an anti-reflective (AR)
material. The AR coating must maximize radiation transmission in scientifically
interesting bands and be cryogenically stable. Such a coating was developed for
the third generation camera, SPT-3G, of the South Pole Telescope (SPT)
experiment, but the materials and techniques used in the development are
general to AR coatings for mm-wave optics. The three-layer
polytetrafluoroethylene-based AR coating is broadband, inexpensive, and can be
manufactured with simple tools. The coating is field tested; AR coated focal
plane elements were deployed in the 2016-2017 austral summer and AR coated
reimaging optics were deployed in 2017-2018.
[24]
oai:arXiv.org:1803.02903 [pdf] - 1724039
Nuclear-recoil energy scale in CDMS II silicon dark-matter detectors
Agnese, R.;
Anderson, A. J.;
Aramaki, T.;
Baker, W.;
Balakishiyeva, D.;
Banik, S.;
Barker, D.;
Thakur, R. Basu;
Bauer, D. A.;
Binder, T.;
Borgland, A.;
Bowles, M. A.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Calkins, R.;
Cartaro, C.;
Cerdeno, D. G.;
Chagani, H.;
Chang, Y. -Y.;
Chen, Y.;
Cooley, J.;
Cornell, B.;
Cushman, P.;
Daal, M.;
Doughty, T.;
Dragowsky, E. M.;
Esteban, L.;
Fallows, S.;
Fascione, E.;
Figueroa-Feliciano, E.;
Fritts, M.;
Gerbier, G.;
Germond, R.;
Ghaith, M.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Harris, H. R.;
Holmgren, D.;
Hong, Z.;
Hsu, L.;
Huber, M. E.;
Iyer, V.;
Jardin, D.;
Jastram, A.;
Jena, C.;
Kelsey, M. H.;
Kennedy, A.;
Kubik, A.;
Kurinsky, N. A.;
Leder, A.;
Asamar, E. Lopez;
Lukens, P.;
MacDonell, D.;
Mahapatra, R.;
Mandic, V.;
Mast, N.;
McCarthy, K. A.;
Miller, E. H.;
Mirabolfathi, N.;
Moffatt, R. A.;
Mohanty, B.;
Moore, D.;
Mendoza, J. D. Morales;
Nelson, J.;
Oser, S. M.;
Page, K.;
Page, W. A.;
Partridge, R.;
Martinez, M. Penalver;
Pepin, M.;
Phipps, A.;
Poudel, S.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Roberts, A.;
Rogers, H. E.;
Robinson, A. E.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schneck, K.;
Schnee, R. W.;
Scorza, S.;
Senapati, K.;
Serfass, B.;
Speller, D.;
Di Stefano, P. C. F.;
Stein, M.;
Street, J.;
Tanaka, H. A.;
Toback, D.;
Underwood, R.;
Villano, A. N.;
von Krosigk, B.;
Welliver, B.;
Wilson, J. S.;
Wilson, M. J.;
Wright, D. H.;
Yellin, S.;
Yen, J. J.;
Young, B. A.;
Zhang, X.;
Zhao, X.
Submitted: 2018-03-07, last modified: 2018-07-27
The Cryogenic Dark Matter Search (CDMS II) experiment aims to detect dark
matter particles that elastically scatter from nuclei in semiconductor
detectors. The resulting nuclear-recoil energy depositions are detected by
ionization and phonon sensors. Neutrons produce a similar spectrum of
low-energy nuclear recoils in such detectors, while most other backgrounds
produce electron recoils. The absolute energy scale for nuclear recoils is
necessary to interpret results correctly. The energy scale can be determined in
CDMS II silicon detectors using neutrons incident from a broad-spectrum
$^{252}$Cf source, taking advantage of a prominent resonance in the neutron
elastic scattering cross section of silicon at a recoil (neutron) energy near
20 (182) keV. Results indicate that the phonon collection efficiency for
nuclear recoils is $4.8^{+0.7}_{-0.9}$% lower than for electron recoils of the
same energy. Comparisons of the ionization signals for nuclear recoils to those
measured previously by other groups at higher electric fields indicate that the
ionization collection efficiency for CDMS II silicon detectors operated at
$\sim$4 V/cm is consistent with 100% for nuclear recoils below 20 keV and
gradually decreases for larger energies to $\sim$75% at 100 keV. The impact of
these measurements on previously published CDMS II silicon results is small.
[25]
oai:arXiv.org:1805.03219 [pdf] - 1679898
Optical Characterization of the SPT-3G Focal Plane
Pan, Zhaodi;
Ade, Peter;
Ahmed, Zeeshan;
Adam, Anderson;
Austermann, Jason;
Avva, Jessica;
Thakur, Ritoban Basu;
Amy, Bender;
Benson, Bradford;
Carlstrom, John;
Carter, Faustin;
Cecil, Thomas;
Chang, Clarence;
Cliche, Jean-Francois;
Cukierman, Ariel;
Denison, Edward;
de Haan, Tijmen;
Ding, Junjia;
Dobbs, Matt;
Dutcher, Daniel;
Everett, Wendeline;
Foster, Allen;
Gannon, Renae;
Gilbert, Adam;
Groh, John;
Halverson, Nils;
Harke-Horsemann, Angelina;
Harrington, Nicholas;
Henning, Jaosn;
Hilton, Gene;
Holzapfel, William;
Huang, Nicholas;
Irwin, Kent;
Jeong, Oliver;
Jonas, Michalle;
Khaire, Trupti;
Kofman, Anna;
Korman, Milo;
Kubik, Donna;
Kuhlmann, Steve;
Kuo, Chaolin;
Lee, Adrian;
Lowitz, Amy;
Meyer, Stephan;
Michalik, Daniel;
Montgomery, Joshua;
Nadolski, Andrew;
Natoli, Tyler;
Nguyen, Hogan;
Noble, Gavin;
Novosad, Valentyn;
Padin, Stephan;
Pearson, John;
Posada, Chrystian;
Rahlin, Alexandra;
Ruhl, John;
Saunders, Lauren;
Sayre, James;
Shirley, Ian;
Shirokoff, Erik;
Smecher, Graeme;
Sobrin, Joshua;
Stark, Antony;
Story, Kyle;
Suzuki, Aritoki;
Tang, Qingyang;
Thompson, Keith;
Tucker, Carole;
Vale, Leila;
Vanderlinde, Keith;
Vieira, Joaquin;
Wang, Gensheng;
Whitehorn, Nathan;
Yefremenko, Volodymyr;
Yoon, Ki Won;
Young, Matt
Submitted: 2018-05-08
The third-generation South Pole Telescope camera is designed to measure the
cosmic microwave background across three frequency bands (95, 150 and 220 GHz)
with ~16,000 transition-edge sensor (TES) bolometers. Each multichroic pixel on
a detector wafer has a broadband sinuous antenna that couples power to six
TESs, one for each of the three observing bands and both polarization
directions, via lumped element filters. Ten detector wafers populate the focal
plane, which is coupled to the sky via a large-aperture optical system. Here we
present the frequency band characterization with Fourier transform
spectroscopy, measurements of optical time constants, beam properties, and
optical and polarization efficiencies of the focal plane. The detectors have
frequency bands consistent with our simulations, and have high average optical
efficiency which is 86%, 77% and 66% for the 95, 150 and 220 GHz detectors. The
time constants of the detectors are mostly between 0.5 ms and 5 ms. The beam is
round with the correct size, and the polarization efficiency is more than 90%
for most of the bolometers
[26]
oai:arXiv.org:1707.01632 [pdf] - 1622232
Low-Mass Dark Matter Search with CDMSlite
SuperCDMS Collaboration;
Agnese, R.;
Anderson, A. J.;
Aralis, T.;
Aramaki, T.;
Arnquist, I. J.;
Baker, W.;
Balakishiyeva, D.;
Barker, D.;
Thakur, R. Basu;
Bauer, D. A.;
Binder, T.;
Bowles, M. A.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Calkins, R.;
Cartaro, C.;
Cerdeno, D. G.;
Chang, Y.;
Chagani, H.;
Chen, Y.;
Cooley, J.;
Cornell, B.;
Cushman, P.;
Daal, M.;
Di Stefano, P. C. F.;
Doughty, T.;
Esteban, L.;
Fascione, E.;
Figueroa-Feliciano, E.;
Fritts, M.;
Gerbier, G.;
Ghaith, M.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Harris, H. R.;
Hong, Z.;
Hoppe, E. W.;
Hsu, L.;
Huber, M. E.;
Iyer, V.;
Jardin, D.;
Jastram, A.;
Jena, C.;
Kelsey, M. H.;
Kennedy, A.;
Kubik, A.;
Kurinsky, N. A.;
Leder, A.;
Loer, B.;
Asamar, E. Lopez;
Lukens, P.;
MacDonell, D.;
Mahapatra, R.;
Mandic, V.;
Mast, N.;
Miller, E. H.;
Mirabolfathi, N.;
Moffatt, R. A.;
Mohanty, B.;
Mendoza, J. D. Morales;
Nelson, J.;
Orrell, J. L.;
Oser, S. M.;
Page, K.;
Page, W. A.;
Partridge, R.;
Pepin, M.;
Martinez, M. Penalver;
Phipps, A.;
Poudel, S.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Reynolds, T.;
Roberts, A.;
Robinson, A. E.;
Rogers, H. E.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schneck, K.;
Schnee, R. W.;
Scorza, S.;
Senapati, K.;
Serfass, B.;
Speller, D.;
Stein, M.;
Street, J.;
Tanaka, H. A.;
Toback, D.;
Underwood, R.;
Villano, A. N.;
von Krosigk, B.;
Welliver, B.;
Wilson, J. S.;
Wilson, M. J;
Wright, D. H.;
Yellin, S.;
Yen, J. J.;
Young, B. A.;
Zhang, X.;
Zhao, X.
Submitted: 2017-07-06, last modified: 2018-01-18
The SuperCDMS experiment is designed to directly detect weakly interacting
massive particles (WIMPs) that may constitute the dark matter in our Galaxy.
During its operation at the Soudan Underground Laboratory, germanium detectors
were run in the CDMSlite mode to gather data sets with sensitivity specifically
for WIMPs with masses ${<}$10 GeV/$c^2$. In this mode, a higher detector-bias
voltage is applied to amplify the phonon signals produced by drifting charges.
This paper presents studies of the experimental noise and its effect on the
achievable energy threshold, which is demonstrated to be as low as 56
eV$_{\text{ee}}$ (electron equivalent energy). The detector-biasing
configuration is described in detail, with analysis corrections for voltage
variations to the level of a few percent. Detailed studies of the
electric-field geometry, and the resulting successful development of a fiducial
parameter, eliminate poorly measured events, yielding an energy resolution
ranging from ${\sim}$9 eV$_{\text{ee}}$ at 0 keV to 101 eV$_{\text{ee}}$ at
${\sim}$10 eV$_{\text{ee}}$. New results are derived for astrophysical
uncertainties relevant to the WIMP-search limits, specifically examining how
they are affected by variations in the most probable WIMP velocity and the
Galactic escape velocity. These variations become more important for WIMP
masses below 10 GeV/$c^2$. Finally, new limits on spin-dependent low-mass
WIMP-nucleon interactions are derived, with new parameter space excluded for
WIMP masses $\lesssim$3 GeV/$c^2$
[27]
oai:arXiv.org:1711.01192 [pdf] - 1955840
Simulating Cosmic Microwave Background anisotropy measurements for
Microwave Kinetic Inductance Devices
Submitted: 2017-11-03
Microwave Kinetic Inductance Devices (MKIDs) are poised to allow for
massively and natively multiplexed photon detectors arrays and are a natural
choice for the next-generation CMB-Stage 4 experiment which will require 105
detectors. In this proceed- ing we discuss what noise performance of present
generation MKIDs implies for CMB measurements. We consider MKID noise spectra
and simulate a telescope scan strategy which projects the detector noise onto
the CMB sky. We then analyze the simulated CMB + MKID noise to understand
particularly low frequency noise affects the various features of the CMB, and
thusly set up a framework connecting MKID characteristics with scan strategies,
to the type of CMB signals we may probe with such detectors.
[28]
oai:arXiv.org:1710.11255 [pdf] - 1697946
Fabrication of antenna-coupled KID array for Cosmic Microwave Background
detection
Submitted: 2017-10-30
Kinetic Inductance Detectors (KIDs) have become an attractive alternative to
traditional bolometers in the sub-mm and mm observing community due to their
innate frequency multiplexing capabilities and simple lithographic processes.
These advantages make KIDs a viable option for the $O(500,000)$ detectors
needed for the upcoming Cosmic Microwave Background - Stage 4 (CMB-S4)
experiment. We have fabricated antenna-coupled MKID array in the 150GHz band
optimized for CMB detection. Our design uses a twin slot antenna coupled to
inverted microstrip made from a superconducting Nb/Al bilayer and SiN$_x$,
which is then coupled to an Al KID grown on high resistivity Si. We present the
fabrication process and measurements of SiN$_x$ microstrip resonators.
[29]
oai:arXiv.org:1706.02464 [pdf] - 1584411
CMB-S4 Technology Book, First Edition
Abitbol, Maximilian H.;
Ahmed, Zeeshan;
Barron, Darcy;
Thakur, Ritoban Basu;
Bender, Amy N.;
Benson, Bradford A.;
Bischoff, Colin A.;
Bryan, Sean A.;
Carlstrom, John E.;
Chang, Clarence L.;
Chuss, David T.;
Crowley, Kevin T.;
Cukierman, Ari;
de Haan, Tijmen;
Dobbs, Matt;
Essinger-Hileman, Tom;
Filippini, Jeffrey P.;
Ganga, Ken;
Gudmundsson, Jon E.;
Halverson, Nils W.;
Hanany, Shaul;
Henderson, Shawn W.;
Hill, Charles A.;
Ho, Shuay-Pwu P.;
Hubmayr, Johannes;
Irwin, Kent;
Jeong, Oliver;
Johnson, Bradley R.;
Kernasovskiy, Sarah A.;
Kovac, John M.;
Kusaka, Akito;
Lee, Adrian T.;
Maria, Salatino;
Mauskopf, Philip;
McMahon, Jeff J.;
Moncelsi, Lorenzo;
Nadolski, Andrew W.;
Nagy, Johanna M.;
Niemack, Michael D.;
O'Brient, Roger C.;
Padin, Stephen;
Parshley, Stephen C.;
Pryke, Clement;
Roe, Natalie A.;
Rostem, Karwan;
Ruhl, John;
Simon, Sara M.;
Staggs, Suzanne T.;
Suzuki, Aritoki;
Switzer, Eric R.;
Tajima, Osamu;
Thompson, Keith L.;
Timbie, Peter;
Tucker, Gregory S.;
Vieira, Joaquin D.;
Vieregg, Abigail G.;
Westbrook, Benjamin;
Wollack, Edward J.;
Yoon, Ki Won;
Young, Karl S.;
Young, Edward Y.
Submitted: 2017-06-08, last modified: 2017-07-05
CMB-S4 is a proposed experiment to map the polarization of the Cosmic
Microwave Background (CMB) to nearly the cosmic variance limit for angular
scales that are accessible from the ground. The science goals and capabilities
of CMB-S4 in illuminating cosmic inflation, measuring the sum of neutrino
masses, searching for relativistic relics in the early universe, characterizing
dark energy and dark matter, and mapping the matter distribution in the
universe have been described in the CMB-S4 Science Book. This Technology Book
is a companion volume to the Science Book. The ambitious science goals of
CMB-S4, a "Stage-4" experiment, require a step forward in experimental
capability from the current Stage=II experiments. To guide this process, we
summarize the current state of CMB instrumentation technology, and identify R&D
efforts necessary to advance it for use in CMB-S4. The book focuses on
technical challenges in four broad areas: Telescope Design; Receiver Optics;
Focal-Plane Optical Coupling; and Focal-Plane Sensor and Readout.
[30]
oai:arXiv.org:1610.00006 [pdf] - 1561019
Projected Sensitivity of the SuperCDMS SNOLAB experiment
Agnese, R.;
Anderson, A. J.;
Aramaki, T.;
Arnquist, I.;
Baker, W.;
Barker, D.;
Thakur, R. Basu;
Bauer, D. A.;
Borgland, A.;
Bowles, M. A.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Calkins, R.;
Cartaro, C.;
Cerdeño, D. G.;
Chagani, H.;
Chen, Y.;
Cooley, J.;
Cornell, B.;
Cushman, P.;
Daal, M.;
Di Stefano, P. C. F.;
Doughty, T.;
Esteban, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Fritts, M.;
Gerbier, G.;
Ghaith, M.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Harris, H. R.;
Hofer, T.;
Holmgren, D.;
Hong, Z.;
Hoppe, E.;
Hsu, L.;
Huber, M. E.;
Iyer, V.;
Jardin, D.;
Jastram, A.;
Kelsey, M. H.;
Kennedy, A.;
Kubik, A.;
Kurinsky, N. A.;
Leder, A.;
Loer, B.;
Asamar, E. Lopez;
Lukens, P.;
Mahapatra, R.;
Mandic, V.;
Mast, N.;
Mirabolfathi, N.;
Moffatt, R. A.;
Mendoza, J. D. Morales;
Orrell, J. L.;
Oser, S. M.;
Page, K.;
Page, W. A.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Poudel, S.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Roberts, A.;
Robinson, A. E.;
Rogers, H. E.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schneck, K.;
Schnee, R. W.;
Serfass, B.;
Speller, D.;
Stein, M.;
Street, J.;
Tanaka, H. A.;
Toback, D.;
Underwood, R.;
Villano, A. N.;
von Krosigk, B.;
Welliver, B.;
Wilson, J. S.;
Wright, D. H.;
Yellin, S.;
Yen, J. J.;
Young, B. A.;
Zhang, X.;
Zhao, X.
Submitted: 2016-09-30
SuperCDMS SNOLAB will be a next-generation experiment aimed at directly
detecting low-mass (< 10 GeV/c$^2$) particles that may constitute dark matter
by using cryogenic detectors of two types (HV and iZIP) and two target
materials (germanium and silicon). The experiment is being designed with an
initial sensitivity to nuclear recoil cross sections ~ 1 x 10$^{-43}$ cm$^2$
for a dark matter particle mass of 1 GeV/c$^2$, and with capacity to continue
exploration to both smaller masses and better sensitivities. The phonon
sensitivity of the HV detectors will be sufficient to detect nuclear recoils
from sub-GeV dark matter. A detailed calibration of the detector response to
low energy recoils will be needed to optimize running conditions of the HV
detectors and to interpret their data for dark matter searches. Low-activity
shielding, and the depth of SNOLAB, will reduce most backgrounds, but
cosmogenically produced $^{3}$H and naturally occurring $^{32}$Si will be
present in the detectors at some level. Even if these backgrounds are x10
higher than expected, the science reach of the HV detectors would be over three
orders of magnitude beyond current results for a dark matter mass of 1
GeV/c$^2$. The iZIP detectors are relatively insensitive to variations in
detector response and backgrounds, and will provide better sensitivity for dark
matter particle masses (> 5 GeV/c$^2$). The mix of detector types (HV and
iZIP), and targets (germanium and silicon), planned for the experiment, as well
as flexibility in how the detectors are operated, will allow us to maximize the
low-mass reach, and understand the backgrounds that the experiment will
encounter. Upgrades to the experiment, perhaps with a variety of
ultra-low-background cryogenic detectors, will extend dark matter sensitivity
down to the "neutrino floor", where coherent scatters of solar neutrinos become
a limiting background.
[31]
oai:arXiv.org:1503.03379 [pdf] - 1458536
Dark matter effective field theory scattering in direct detection
experiments
Schneck, K.;
Cabrera, B.;
Cerdeno, D. G.;
Mandic, V.;
Rogers, H. E.;
Agnese, R.;
Anderson, A. J.;
Asai, M.;
Balakishiyeva, D.;
Barker, D.;
Thakur, R. Basu;
Bauer, D. A.;
Billard, J.;
Borgland, A.;
Brandt, D.;
Brink, P. L.;
Bunker, R.;
Caldwell, D. O.;
Calkins, R.;
Chagani, H.;
Chen, Y.;
Cooley, J.;
Cornell, B.;
Crewdson, C. H.;
Cushman, P.;
Daal, M.;
Di Stefano, P. C. F.;
Doughty, T.;
Esteban, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Harris, H. R.;
Hofer, T.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Jardin, D. M.;
Jastram, A.;
Kamaev, O.;
Kara, B.;
Kelsey, M. H.;
Kennedy, A.;
Leder, A.;
Loer, B.;
Asamar, E. Lopez;
Lukens, P.;
Mahapatra, R.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moffatt, R. A.;
Mendoza, J. D. Morales;
Oser, S. M.;
Page, K.;
Page, W. A.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Prasad, K.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Ricci, Y.;
Roberts, A.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schnee, R. W.;
Scorza, S.;
Serfass, B.;
Shank, B.;
Speller, D.;
Toback, D.;
Upadhyayula, S.;
Villano, A. N.;
Welliver, B.;
Wilson, J. S.;
Wright, D. H.;
Yang, X.;
Yellin, S.;
Yen, J. J.;
Young, B. A.;
Zhang, J.
Submitted: 2015-03-11, last modified: 2016-08-16
We examine the consequences of the effective field theory (EFT) of dark
matter-nucleon scattering for current and proposed direct detection
experiments. Exclusion limits on EFT coupling constants computed using the
optimum interval method are presented for SuperCDMS Soudan, CDMS II, and LUX,
and the necessity of combining results from multiple experiments in order to
determine dark matter parameters is discussed. We demonstrate that spectral
differences between the standard dark matter model and a general EFT
interaction can produce a bias when calculating exclusion limits and when
developing signal models for likelihood and machine learning techniques. We
also discuss the implications of the EFT for the next-generation (G2) direct
detection experiments and point out regions of complementarity in the EFT
parameter space.
[32]
oai:arXiv.org:1509.02448 [pdf] - 1371572
WIMP-Search Results from the Second CDMSlite Run
SuperCDMS Collaboration;
Agnese, R.;
Anderson, A. J.;
Aramaki, T.;
Asai, M.;
Baker, W.;
Balakishiyeva, D.;
Barker, D.;
Thakur, R. Basu;
Bauer, D. A.;
Billard, J.;
Borgland, A.;
Bowles, M. A.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Calkins, R.;
Cerdeno, D. G.;
Chagani, H.;
Chen, Y.;
Cooley, J.;
Cornell, B.;
Cushman, P.;
Daal, M.;
Di Stefano, P. C. F.;
Doughty, T.;
Esteban, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Ghaith, M.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Harris, H. R.;
Hofer, T.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Jardin, D.;
Jastram, A.;
Kamaev, O.;
Kara, B.;
Kelsey, M. H.;
Kennedy, A.;
Leder, A.;
Loer, B.;
Asamar, E. Lopez;
Lukens, P.;
Mahapatra, R.;
Mandic, V.;
Mast, N.;
Mirabolfathi, N.;
Moffatt, R. A.;
Mendoza, J. D. Morales;
Oser, S. M.;
Page, K.;
Page, W. A.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Prasad, K.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Ricci, Y.;
Roberts, A.;
Rogers, H. E.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schneck, K.;
Schnee, R. W.;
Scorza, S.;
Serfass, B.;
Shank, B.;
Speller, D.;
Toback, D.;
Underwood, R.;
Upadhyayula, S.;
Villano, A. N.;
Welliver, B.;
Wilson, J. S.;
Wright, D. H.;
Yellin, S.;
Yen, J. J.;
Young, B. A.;
Zhang, J.
Submitted: 2015-09-08, last modified: 2016-03-09
The CDMS low ionization threshold experiment (CDMSlite) uses cryogenic
germanium detectors operated at a relatively high bias voltage to amplify the
phonon signal in the search for weakly interacting massive particles (WIMPs).
Results are presented from the second CDMSlite run with an exposure of 70 kg
days, which reached an energy threshold for electron recoils as low as 56 eV. A
fiducialization cut reduces backgrounds below those previously reported by
CDMSlite. New parameter space for the WIMP-nucleon spin-independent cross
section is excluded for WIMP masses between 1.6 and 5.5 GeV/$c^2$.
[33]
oai:arXiv.org:1504.05871 [pdf] - 1293576
Improved WIMP-search reach of the CDMS II germanium data
Agnese, R.;
Anderson, A. J.;
Asai, M.;
Balakishiyeva, D.;
Barker, D.;
Thakur, R. Basu;
Bauer, D. A.;
Billard, J.;
Borgland, A.;
Bowles, M. A.;
Brandt, D.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Calkins, R.;
Cerdeño, D. G.;
Chagani, H.;
Chen, Y.;
Cooley, J.;
Cornell, B.;
Crewdson, C. H.;
Cushman, P.;
Daal, M.;
Di Stefano, P. C. F.;
Doughty, T.;
Esteban, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Harris, H. R.;
Hertel, S. A.;
Hofer, T.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Jardin, D.;
Jastram, A.;
Kamaev, O.;
Kara, B.;
Kelsey, M. H.;
Kennedy, A.;
Kiveni, M.;
Koch, K.;
Leder, A.;
Loer, B.;
Asamar, E. Lopez;
Lukens, P.;
Mahapatra, R.;
Mandic, V.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moffatt, R. A.;
Oser, S. M.;
Page, K.;
Page, W. A.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Prasad, K.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Ricci, Y.;
Rogers, H. E.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schneck, K.;
Schnee, R. W.;
Scorza, S.;
Serfass, B.;
Shank, B.;
Speller, D.;
Toback, D.;
Upadhyayula, S.;
Villano, A. N.;
Welliver, B.;
Wilson, J. S.;
Wright, D. H.;
Yang, X.;
Yellin, S.;
Yen, J. J.;
Young, B. A.;
Zhang, J.
Submitted: 2015-04-22, last modified: 2015-10-13
CDMS II data from the 5-tower runs at the Soudan Underground Laboratory were
reprocessed with an improved charge-pulse fitting algorithm. Two new analysis
techniques to reject surface-event backgrounds were applied to the 612 kg days
germanium-detector WIMP-search exposure. An extended analysis was also
completed by decreasing the 10 keV analysis threshold to $\sim$5 keV, to
increase sensitivity near a WIMP mass of 8 GeV/$c^2$. After unblinding, there
were zero candidate events above a deposited energy of 10 keV and 6 events in
the lower-threshold analysis. This yielded minimum WIMP-nucleon
spin-independent scattering cross-section limits of $1.8 \times 10^{-44}$ and
$1.18 \times 10 ^{-41}$ cm$^2$ at 90\% confidence for 60 and 8.6 GeV/$c^2$
WIMPs, respectively. This improves the previous CDMS II result by a factor of
2.4 (2.7) for 60 (8.6) GeV/$c^2$ WIMPs.
[34]
oai:arXiv.org:1409.3270 [pdf] - 969775
First direct limits on Lightly Ionizing Particles with electric charge
less than $e/6$
Agnese, R.;
Anderson, A. J.;
Balakishiyeva, D.;
Thakur, R. Basu;
Bauer, D. A.;
Billard, J.;
Borgland, A.;
Bowles, M. A.;
Brandt, D.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Cerdeno, D. G.;
Chagani, H.;
Chen, Y.;
Cooley, J.;
Cornell, B.;
Crewdson, C. H.;
Cushman, P.;
Daal, M.;
Di Stefano, P. C. F.;
Doughty, T.;
Esteban, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Harris, H. R.;
Hertel, S. A.;
Hofer, T.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Jastram, A.;
Kamaev, O.;
Kara, B.;
Kelsey, M. H.;
Kennedy, A.;
Kiveni, M.;
Koch, K.;
Leder, A.;
Loer, B.;
Asamar, E. Lopez;
Mahapatra, R.;
Mandic, V.;
Martinez, C.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moffatt, R. A.;
Moore, D. C.;
Nelson, H.;
Nelson, R. H.;
Ogburn, R. W.;
Page, K.;
Page, W. A.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Prasad, K.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Ricci, Y.;
Rogers, H. E.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schneck, K.;
Schnee, R. W.;
Scorza, S.;
Serfass, B.;
Shank, B.;
Speller, D.;
Upadhyayula, S.;
Villano, A. N.;
Welliver, B.;
Wright, D. H.;
Yellin, S.;
Yen, J. J.;
Young, B. A.;
Zhang, J.
Submitted: 2014-09-10, last modified: 2015-02-03
While the Standard Model of particle physics does not include free particles
with fractional charge, experimental searches have not ruled out their
existence. We report results from the Cryogenic Dark Matter Search (CDMS II)
experiment that give the first direct-detection limits for
cosmogenically-produced relativistic particles with electric charge lower than
$e$/6. A search for tracks in the six stacked detectors of each of two of the
CDMS II towers found no candidates, thereby excluding new parameter space for
particles with electric charges between $e$/6 and $e$/200.
[35]
oai:arXiv.org:1410.1003 [pdf] - 975596
Maximum Likelihood Analysis of Low Energy CDMS II Germanium Data
SuperCDMS Collaboration;
Agnese, R.;
Anderson, A. J.;
Balakishiyeva, D.;
Thakur, R. Basu;
Bauer, D. A.;
Billard, J.;
Borgland, A.;
Bowles, M. A.;
Brandt, D.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Cerdeno, D. G.;
Chagani, H.;
Chen, Y.;
Cooley, J.;
Cornell, B.;
Crewdson, C. H.;
Cushman, P.;
Daal, M.;
Di Stefano, P. C. F.;
Doughty, T.;
Esteban, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Fritts, M.;
Godfrey, G. L.;
Golwala, S. R.;
Graham, M.;
Hall, J.;
Harris, H. R.;
Hertel, S. A.;
Hofer, T.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Jastram, A.;
Kamaev, O.;
Kara, B.;
Kelsey, M. H.;
Kennedy, A.;
Kiveni, M.;
Koch, K.;
Leder, A.;
Loer, B.;
Asamar, E. Lopez;
Mahapatra, R.;
Mandic, V.;
Martinez, C.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moffatt, R. A.;
Moore, D. C.;
Nelson, R. H.;
Oser, S. M.;
Page, K.;
Page, W. A.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Prasad, K.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Ricci, Y.;
Rogers, H. E.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schneck, K.;
Schnee, R. W.;
Scorza, S.;
Serfass, B.;
Shank, B.;
Speller, D.;
Upadhyayula, S.;
Villano, A. N.;
Welliver, B.;
Wright, D. H.;
Yellin, S.;
Yen, J. J.;
Young, B. A.;
Zhang, J.
Submitted: 2014-10-03
We report on the results of a search for a Weakly Interacting Massive
Particle (WIMP) signal in low-energy data of the Cryogenic Dark Matter Search
(CDMS~II) experiment using a maximum likelihood analysis. A background model is
constructed using GEANT4 to simulate the surface-event background from
$^{210}$Pb decay-chain events, while using independent calibration data to
model the gamma background. Fitting this background model to the data results
in no statistically significant WIMP component. In addition, we perform fits
using an analytic ad hoc background model proposed by Collar and Fields, who
claimed to find a large excess of signal-like events in our data. We confirm
the strong preference for a signal hypothesis in their analysis under these
assumptions, but excesses are observed in both single- and multiple-scatter
events, which implies the signal is not caused by WIMPs, but rather reflects
the inadequacy of their background model.
[36]
oai:arXiv.org:1402.7137 [pdf] - 841566
Search for Low-Mass WIMPs with SuperCDMS
Agnese, R.;
Anderson, A. J.;
Asai, M.;
Balakishiyeva, D.;
Thakur, R. Basu;
Bauer, D. A.;
Beaty, J.;
Billard, J.;
Borgland, A.;
Bowles, M. A.;
Brandt, D.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Cerdeno, D. G.;
Chagani, H.;
Chen, Y.;
Cherry, M.;
Cooley, J.;
Cornell, B.;
Crewdson, C. H.;
Cushman, P.;
Daal, M.;
DeVaney, D.;
Di Stefano, P. C. F.;
Silva, E. Do Couto E;
Doughty, T.;
Esteban, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Hansen, S.;
Harris, H. R.;
Hertel, S. A.;
Hines, B. A.;
Hofer, T.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Jastram, A.;
Kamaev, O.;
Kara, B.;
Kelsey, M. H.;
Kenany, S.;
Kennedy, A.;
Kiveni, M.;
Koch, K.;
Leder, A.;
Loer, B.;
Asamar, E. Lopez;
Mahapatra, R.;
Mandic, V.;
Martinez, C.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moffatt, R. A.;
Nelson, R. H.;
Novak, L.;
Page, K.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Platt, M.;
Prasad, K.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Resch, R. W.;
Ricci, Y.;
Ruschman, M.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schmitt, R. L.;
Schneck, K.;
Schnee, R. W.;
Scorza, S.;
Seitz, D. N.;
Serfass, B.;
Shank, B.;
Speller, D.;
Tomada, A.;
Upadhyayula, S.;
Villano, A. N.;
Welliver, B.;
Wright, D. H.;
Yellin, S.;
Yen, J. J.;
Young, B. A.;
Zhang, J.
Submitted: 2014-02-28, last modified: 2014-03-12
We report a first search for weakly interacting massive particles (WIMPs)
using the background rejection capabilities of SuperCDMS. An exposure of 577
kg-days was analyzed for WIMPs with mass < 30 GeV/c2, with the signal region
blinded. Eleven events were observed after unblinding. We set an upper limit on
the spin-independent WIMP-nucleon cross section of 1.2e-42 cm2 at 8 GeV/c2.
This result is in tension with WIMP interpretations of recent experiments and
probes new parameter space for WIMP-nucleon scattering for WIMP masses < 6
GeV/c2.
[37]
oai:arXiv.org:1309.3259 [pdf] - 779590
CDMSlite: A Search for Low-Mass WIMPs using Voltage-Assisted
Calorimetric Ionization Detection in the SuperCDMS Experiment
Agnese, R.;
Anderson, A. J.;
Asai, M.;
Balakishiyeva, D.;
Thakur, R. Basu;
Bauer, D. A.;
Billard, J.;
Borgland, A.;
Bowles, M. A.;
Brandt, D.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Cerdeno, D. G.;
Chagani, H.;
Cooley, J.;
Cornell, B.;
Crewdson, C. H.;
Cushman, P.;
Daal, M.;
Di Stefano, P. C. F.;
Doughty, T.;
Esteban, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Harris, H. R.;
Hertel, S. A.;
Hofer, T.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Jastram, A.;
Kamaev, O.;
Kara, B.;
Kelsey, M. H.;
Kennedy, A.;
Kiveni, M.;
Koch, K.;
Loer, B.;
Asamar, E. Lopez;
Mahapatra, R.;
Mandic, V.;
Martinez, C.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moffatt, R. A.;
Moore, D. C.;
Nadeau, P.;
Nelson, R. H.;
Page, K.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Prasad, K.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Ricci, Y.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schneck, K.;
Schnee, R. W.;
Scorza, S.;
Serfass, B.;
Shank, B.;
Speller, D.;
Villano, A. N.;
Welliver, B.;
Wright, D. H.;
Yellin, S.;
Yen, J. J.;
Young, B. A.;
Zhang, J.
Submitted: 2013-09-12, last modified: 2013-12-20
SuperCDMS is an experiment designed to directly detect Weakly Interacting
Massive Particles (WIMPs), a favored candidate for dark matter ubiquitous in
the Universe. In this paper, we present WIMP-search results using a
calorimetric technique we call CDMSlite, which relies on voltage- assisted
Luke-Neganov amplification of the ionization energy deposited by particle
interactions. The data were collected with a single 0.6 kg germanium detector
running for 10 live days at the Soudan Underground Laboratory. A low energy
threshold of 170 eVee (electron equivalent) was obtained, which allows us to
constrain new WIMP-nucleon spin-independent parameter space for WIMP masses
below 6 GeV/c2.
[38]
oai:arXiv.org:1304.4279 [pdf] - 732067
Silicon Detector Dark Matter Results from the Final Exposure of CDMS II
CDMS Collaboration;
Agnese, R.;
Ahmed, Z.;
Anderson, A. J.;
Arrenberg, S.;
Balakishiyeva, D.;
Thakur, R. Basu;
Bauer, D. A.;
Billard, J.;
Borgland, A.;
Brandt, D.;
Brink, P. L.;
Bruch, T.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Cerdeno, D. G.;
Chagani, H.;
Cooley, J.;
Cornell, B.;
Crewdson, C. H.;
Cushman, P.;
Daal, M.;
Dejongh, F.;
Silva, E. Do Couto E;
Doughty, T.;
Esteban, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Filippini, J.;
Fox, J.;
Fritts, M.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Harris, R. H.;
Hertel, S. A.;
Hofer, T.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Jastram, A.;
Kamaev, O.;
Kara, B.;
Kelsey, M. H.;
Kennedy, A.;
Kim, P.;
Kiveni, M.;
Koch, K.;
Kos, M.;
Leman, S. W.;
Loer, B.;
Asamar, E. Lopez;
Mahapatra, R.;
Mandic, V.;
Martinez, C.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moffatt, R. A.;
Moore, D. C.;
Nadeau, P.;
Nelson, R. H.;
Page, K.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Prasad, K.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Ricci, Y.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schneck, K.;
Schnee, R. W.;
Scorza, S.;
Serfass, B.;
Shank, B.;
Speller, D.;
Sundqvist, K. M.;
Villano, A. N.;
Welliver, B.;
Wright, D. H.;
Yellin, S.;
Yen, J. J.;
Yoo, J.;
Young, B. A.;
Zhang, J.
Submitted: 2013-04-15, last modified: 2013-10-11
We report results of a search for Weakly Interacting Massive Particles
(WIMPS) with the silicon detectors of the CDMS II experiment. This blind
analysis of 140.2 kg-days of data taken between July 2007 and September 2008
revealed three WIMP-candidate events with a surface-event background estimate
of 0.41^{+0.20}_{-0.08}(stat.)^{+0.28}_{-0.24}(syst.). Other known backgrounds
from neutrons and 206Pb are limited to < 0.13 and <0.08 events at the 90%
confidence level, respectively. The exposure of this analysis is equivalent to
23.4 kg-days for a recoil energy range of 7-100 keV for a WIMP of mass 10
GeV/c2. The probability that the known backgrounds would produce three or more
events in the signal region is 5.4%. A profile likelihood ratio test of the
three events that includes the measured recoil energies gives a 0.19%
probability for the known-background-only hypothesis when tested against the
alternative WIMP+background hypothesis. The highest likelihood occurs for a
WIMP mass of 8.6 GeV/c2 and WIMP-nucleon cross section of 1.9e-41 cm2.
[39]
oai:arXiv.org:1305.2405 [pdf] - 1530127
Demonstration of Surface Electron Rejection with Interleaved Germanium
Detectors for Dark Matter Searches
Agnese, R.;
Anderson, A. J.;
Balakishiyeva, D.;
Thakur, R. Basu;
Bauer, D. A.;
Borgland, A.;
Brandt, D.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Cerdeno, D. G.;
Chagani, H.;
Cherry, M.;
Cooley, J.;
Cornell, B.;
Crewdson, C. H.;
Cushman, P.;
Daal, M.;
Di Stefano, P. C. F.;
Silva, E. Do Couto E;
Doughty, T.;
Esteban, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Fox, J.;
Fritts, M.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Harris, H. R.;
Hasi, J.;
Hertel, S. A.;
Hines, B. A.;
Hofer, T.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Jastram, A.;
Kamaev, O.;
Kara, B.;
Kelsey, M. H.;
Kenany, S. A.;
Kennedy, A.;
Kenney, C. J.;
Kiveni, M.;
Koch, K.;
Loer, B.;
Asamar, E. Lopez;
Mahapatra, R.;
Mandic, V.;
Martinez, C.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moffatt, R. A.;
Moore, D. C.;
Nadeau, P.;
Nelson, R. H.;
Novak, L.;
Page, K.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Prasad, K.;
Pyle, M.;
Qiu, H.;
Radpour, R.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Resch, R. W.;
Ricci, Y.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schmitt, R.;
Schneck, K.;
Schnee, R. W.;
Scorza, S.;
Seitz, D.;
Serfass, B.;
Shank, B.;
Speller, D.;
Tomada, A.;
Villano, A. N.;
Welliver, B.;
Wright, D. H.;
Yellin, S.;
Yen, J. J.;
Young, B. A.;
Zhang, J.
Submitted: 2013-05-10, last modified: 2013-10-04
The SuperCDMS experiment in the Soudan Underground Laboratory searches for
dark matter with a 9-kg array of cryogenic germanium detectors. Symmetric
sensors on opposite sides measure both charge and phonons from each particle
interaction, providing excellent discrimination between electron and nuclear
recoils, and between surface and interior events. Surface event rejection
capabilities were tested with two $^{210}$Pb sources producing $\sim$130 beta
decays/hr. In $\sim$800 live hours, no events leaked into the 8--115 keV signal
region, giving upper limit leakage fraction $1.7 \times 10^{-5}$ at 90% C.L.,
corresponding to $< 0.6$ surface event background in the future 200-kg
SuperCDMS SNOLAB experiment.
[40]
oai:arXiv.org:1304.3706 [pdf] - 719385
Silicon detector results from the first five-tower run of CDMS II
CDMS Collaboration;
Agnese, R.;
Ahmed, Z.;
Anderson, A. J.;
Arrenberg, S.;
Balakishiyeva, D.;
Thakur, R. Basu;
Bauer, D. A.;
Borgland, A.;
Brandt, D.;
Brink, P. L.;
Bruch, T.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Cerdeno, D. G.;
Chagani, H.;
Cooley, J.;
Cornell, B.;
Crewdson, C. H.;
Cushman, P.;
Daal, M.;
Dejongh, F.;
Di Stefano, P. C. F.;
Silva, E. do Couto e;
Doughty, T.;
Esteban, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Filippini, J.;
Fox, J.;
Fritts, M.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Harris, R. H.;
Hertel, S. A.;
Hofer, T.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Jastram, A.;
Kamaev, O.;
Kara, B.;
Kelsey, M. H.;
Kennedy, A.;
Kim, P.;
Kiveni, M.;
Koch, K.;
Kos, M.;
Leman, S. W.;
Lopez-Asamar, E.;
Mahapatra, R.;
Mandic, V.;
Martinez, C.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moffatt, R. A.;
Moore, D. C.;
Nadeau, P.;
Nelson, R. H.;
Page, K.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Prasad, K.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Ricci, Y.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schneck, K.;
Schnee, R. W.;
Scorza, S.;
Serfass, B.;
Shank, B.;
Speller, D.;
Sundqvist, K. M.;
Villano, A. N.;
Welliver, B.;
Wright, D. H.;
Yellin, S.;
Yen, J. J.;
Yoo, J.;
Young, B. A.;
Zhan, J.
Submitted: 2013-04-12, last modified: 2013-09-14
We report results of a search for Weakly Interacting Massive Particles
(WIMPs) with the Si detectors of the CDMS II experiment. This report describes
a blind analysis of the first data taken with CDMS II's full complement of
detectors in 2006-2007; results from this exposure using the Ge detectors have
already been presented. We observed no candidate WIMP-scattering events in an
exposure of 55.9 kg-days before analysis cuts, with an expected background of
~1.1 events. The exposure of this analysis is equivalent to 10.3 kg-days over a
recoil energy range of 7-100 keV for an ideal Si detector and a WIMP mass of 10
GeV/c2. These data set an upper limit of 1.7x10-41 cm2 on the WIMP-nucleon
spin-independent cross section of a 10 GeV/c2 WIMP. These data exclude
parameter space for spin-independent WIMP-nucleon elastic scattering that is
relevant to recent searches for low-mass WIMPs.
[41]
oai:arXiv.org:1203.1309 [pdf] - 564223
Search for annual modulation in low-energy CDMS-II data
CDMS Collaboration;
Ahmed, Z.;
Akerib, D. S.;
Anderson, A. J.;
Arrenberg, S.;
Bailey, C. N.;
Balakishiyeva, D.;
Baudis, L.;
Bauer, D. A.;
Brink, P. L.;
Bruch, T.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Cooley, J.;
Cushman, P.;
Daal, M.;
DeJongh, F.;
Di Stefano, P. C. F.;
Dragowsky, M. R.;
Fallows, S.;
Figueroa-Feliciano, E.;
Filippini, J.;
Fox, J.;
Fritts, M.;
Golwala, S. R.;
Hall, J.;
Hertel, S. A.;
Hofer, T.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Kamaev, O.;
Kiveni, M.;
Kos, M.;
Leman, S. W.;
Liu, S.;
Mahapatra, R.;
Mandic, V.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moore, D. C.;
Nelson, H.;
Ogburn, R. W.;
Phipps, A.;
Prasad, K.;
Pyle, M.;
Qiu, X.;
Rau, W.;
Reisetter, A.;
Ricci, Y.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schnee, R. W.;
Seitz, D.;
Serfass, B.;
Speller, D.;
Sundqvist, K. M.;
Tarka, M.;
Thakur, R. B.;
Villano, A. N.;
Welliver, B.;
Yellin, S.;
Yoo, J.;
Young, B. A.;
Zhang, J.
Submitted: 2012-03-06, last modified: 2012-09-18
We report limits on annual modulation of the low-energy event rate from the
Cryogenic Dark Matter Search (CDMS II) experiment at the Soudan Underground
Laboratory. Such a modulation could be produced by interactions from Weakly
Interacting Massive Particles (WIMPs) with masses ~10 GeV/c^2. We find no
evidence for annual modulation in the event rate of veto-anticoincident
single-detector interactions consistent with nuclear recoils, and constrain the
magnitude of any modulation to <0.06 event [keVnr kg day]^-1 in the 5-11.9
keVnr energy range at the 99% confidence level. These results disfavor an
explanation for the reported modulation in the 1.2-3.2 keVee energy range in
CoGeNT in terms of nuclear recoils resulting from elastic scattering of WIMPs
at >98% confidence. For events consistent with electron recoils, no significant
modulation is observed for either single- or multiple-detector interactions in
the 3.0-7.4 keVee range.
[42]
oai:arXiv.org:1201.3685 [pdf] - 1093064
Low-Mass WIMP Sensitivity and Statistical Discrimination of Electron and
Nuclear Recoils by Varying Luke-Neganov Phonon Gain in Semiconductor
Detectors
Submitted: 2012-01-17
Amplifying the phonon signal in a semiconductor dark matter detector can be
accomplished by operating at high voltage bias and converting the electrostatic
potential energy into Luke-Neganov phonons. This amplification method has been
validated at up to |E|=40V/cm without producing leakage in CDMSII Ge detectors,
allowing sensitivity to a benchmark WIMP with mass = 8GeV and cross section
1.8e-42cm^2 assuming flat electronic recoil backgrounds near threshold.
Furthermore, for the first time we show that differences in Luke-Neganov gain
for nuclear and electronic recoils can be used to discriminate statistically
between low-energy background and a hypothetical WIMP signal by operating at
two distinct voltage biases. Specifically, 99% of events have p-value<1e-8 for
a simulated 20kg-day experiment with a benchmark WIMP signal with mass =8GeV
and cross section =3.3e-41cm^2.
[43]
oai:arXiv.org:astro-ph/0702671 [pdf] - 89725
Do Black Holes End up as Quark Stars ?
Submitted: 2007-02-25
The possibility of the existence of quark stars has been discussed by several
authors since 1970. Recently, it has been pointed out that two putative neutron
stars, RXJ 1856.5 - 3754 in Corona Australis and 3C58 in Cassiopeia are too
small and too dense to be neutron stars; they show evidence of being quark
stars. Apart from these two objects, there are several other compact objects
which fit neither in the category of neutron stars nor in that of black holes.
It has been suggested that they may be quark stars.In this paper it is shown
that a black hole cannot collapse to a singularity, instead it may end up as a
quark star. In this context it is shown that a gravitationally collapsing black
hole acts as an ultrahigh energy particle accelerator, hitherto inconceivable
in any terrestrial laboratory, that continually accelerates particles
comprising the matter in the black hole. When the energy \textit{E} of the
particles in the black hole is $\geq 10^{2}$GeV, or equivalently the
temperature \textit{T} of the matter in the black holes is $\geq 10^{15}$K, the
entire matter in the black hole will be converted into quark-gluon plasma
permeated by leptons. Since quarks and leptons are spin 1/2 particles,they are
governed by Pauli's exclusion principle. Consequently, one of the two
possibilities will occur; either Pauli's exclusion principle would be violated
and the black hole would collapse to a singularity, or the collapse of the
black hole to a singularity would be inhibited by Pauli's exclusion principle,
and the black hole would eventually explode with a mini bang of a sort. After
explosion, the remnant core would stabilize as a quark star.