Normalized to: Telfer, S.
[1]
oai:arXiv.org:1602.05939 [pdf] - 1538892
First search for a dark matter annual modulation signal with NaI(Tl) in
the Southern Hemisphere by DM-Ice17
Collaboration, DM-Ice;
:;
de Souza, E. Barbosa;
Cherwinka, J.;
Cole, A.;
Ezeribe, A. C.;
Grant, D.;
Halzen, F.;
Heeger, K. M.;
Hsu, L.;
Hubbard, A. J. F.;
Jo, J. H.;
Karle, A.;
Kauer, M.;
Kudryavtsev, V. A.;
Lim, K. E.;
Macdonald, C.;
Maruyama, R. H.;
Mouton, F.;
Paling, S. M.;
Pettus, W.;
Pierpoint, Z. P.;
Reilly, B. N.;
Robinson, M.;
Rogers, F. R.;
Sandstrom, P.;
Scarff, A.;
Spooner, N. J. C.;
Telfer, S.;
Yang, L.
Submitted: 2016-02-18, last modified: 2017-02-28
We present the first search for a dark matter annual modulation signal in the
Southern Hemisphere conducted with NaI(Tl) detectors, performed by the DM-Ice17
experiment. Nuclear recoils from dark matter interactions are expected to yield
an annually modulated signal independent of location within the Earth's
hemispheres. DM-Ice17, the first step in the DM-Ice experimental program,
consists of 17 kg of NaI(Tl) located at the South Pole under 2200 m.w.e.
overburden of Antarctic glacial ice. Taken over 3.6 years for a total exposure
of 60.8 kg yr, DM-Ice17 data are consistent with no modulation in the energy
range of 4-20 keV, providing the strongest limits on weakly interacting massive
particle dark matter from a direct detection experiment located in the Southern
Hemisphere. The successful deployment and stable long-term operation of
DM-Ice17 establishes the South Pole ice as a viable location for future dark
matter searches and in particular for a high-sensitivity NaI(Tl) dark matter
experiment to directly test the DAMA/LIBRA claim of the observation of dark
matter.
[2]
oai:arXiv.org:1509.02486 [pdf] - 1364880
Measurement of Muon Annual Modulation and Muon-Induced Phosphorescence
in NaI(Tl) Crystals with DM-Ice17
Collaboration, DM-Ice;
:;
Cherwinka, J.;
Grant, D.;
Halzen, F.;
Heeger, K. M.;
Hsu, L.;
Hubbard, A. J. F.;
Karle, A.;
Kauer, M.;
Kudryavtsev, V. A.;
Lim, K. E.;
Macdonald, C.;
Maruyama, R. H.;
Paling, S.;
Pettus, W.;
Pierpoint, Z. P.;
Reilly, B. N.;
Robinson, M.;
Sandstrom, P.;
Spooner, N. J. C.;
Telfer, S.;
Yang, L.
Submitted: 2015-09-08, last modified: 2016-02-25
We report the measurement of muons and muon-induced phosphorescence in
DM-Ice17, a NaI(Tl) direct detection dark matter experiment at the South Pole.
Muon interactions in the crystal are identified by their observed pulse shape
and large energy depositions. The measured muon rate in DM-Ice17 is 2.93 +/-
0.04 muons/crystal/day with a modulation amplitude of 12.3 +/- 1.7%, consistent
with expectation. Following muon interactions, we observe long-lived
phosphorescence in the NaI(Tl) crystals with a decay time of 5.5 +/- 0.5 s. The
prompt energy deposited by a muon is correlated to the amount of delayed
phosphorescence, the brightest of which consist of tens of millions of photons.
These photons are distributed over tens of seconds with a rate and arrival
timing that do not mimic a scintillation signal above 2 keVee. While the
properties of phosphorescence vary among individual crystals, the
annually-modulating signal observed by DAMA cannot be accounted for by
phosphorescence with the characteristics observed in DM-Ice17.
[3]
oai:arXiv.org:1410.7821 [pdf] - 1250420
First background-free limit from a directional dark matter experiment:
results from a fully fiducialised DRIFT detector
Battat, J. B. R.;
Brack, J.;
Daw, E.;
Dorofeev, A.;
Ezeribe, A. C.;
Gauvreau, J. -L.;
Gold, M.;
Harton, J. L.;
Landers, J. M.;
Law, E.;
Lee, E. R.;
Loomba, D.;
Lumnah, A.;
Matthews, J. A. J.;
Miller, E. H.;
Monte, A.;
Mouton, F.;
Murphy, A. StJ.;
Paling, S. M.;
Phan, N.;
Robinson, M.;
Sadler, S. W.;
Scarff, A.;
Schuckman, F.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Telfer, S.;
Vahsen, S. E.;
Walker, D.;
Warner, D.;
Yuriev, L.
Submitted: 2014-10-28, last modified: 2015-07-23
The addition of O2 to gas mixtures in time projection chambers containing CS2
has recently been shown to produce multiple negative ions that travel at
slightly different velocities. This allows a measurement of the absolute
position of ionising events in the z (drift) direction. In this work, we apply
the z-fiducialisation technique to a directional dark matter search. In
particular, we present results from a 46.3 live-day source-free exposure of the
DRIFT-IId detector run in this completely new mode. With full-volume
fiducialisation, we have achieved the first background-free operation of a
directional detector. The resulting exclusion curve for spin-dependent
WIMP-proton interactions reaches 1.1 pb at 100 GeV/c2, a factor of 2 better
than our previous work. We describe the automated analysis used here, and argue
that detector upgrades, implemented after the acquisition of these data, will
bring an additional factor of >3 improvement in the near future.
[4]
oai:arXiv.org:1401.4804 [pdf] - 896930
First data from DM-Ice17
Collaboration, DM-Ice;
:;
Cherwinka, J.;
Grant, D.;
Halzen, F.;
Heeger, K. M.;
Hsu, L.;
Hubbard, A. J. F.;
Karle, A.;
Kauer, M.;
Kudryavtsev, V. A.;
Macdonald, C.;
Maruyama, R. H.;
Paling, S.;
Pettus, W.;
Pierpoint, Z. P.;
Reilly, B. N.;
Robinson, M.;
Sandstrom, P.;
Spooner, N. J. C.;
Telfer, S.;
Yang, L.
Submitted: 2014-01-20, last modified: 2014-11-13
We report the first analysis of background data from DM-Ice17, a
direct-detection dark matter experiment consisting of 17 kg of NaI(Tl) target
material. It was codeployed with IceCube 2457 m deep in the South Pole glacial
ice in December 2010 and is the first such detector operating in the Southern
Hemisphere. The background rate in the 6.5 - 8.0 keVee region is measured to be
7.9 +/- 0.4 counts/day/keV/kg. This is consistent with the expected background
from the detector assemblies with negligible contributions from the surrounding
ice. The successful deployment and operation of DM-Ice17 establishes the South
Pole ice as a viable location for future underground, low-background
experiments in the Southern Hemisphere. The detector assembly and deployment
are described here, as well as the analysis of the DM-Ice17 backgrounds based
on data from the first two years of operation after commissioning, July 2011 -
June 2013.
[5]
oai:arXiv.org:1407.3938 [pdf] - 1215675
Radon in the DRIFT-II directional dark matter TPC: emanation, detection
and mitigation
Battat, J. B. R.;
Brack, J.;
Daw, E.;
Dorofeev, A.;
Ezeribe, A. C.;
Fox, J. R.;
Gauvreau, J. -L.;
Gold, M.;
Harmon, L. J.;
Harton, J. L.;
Landers, J. M.;
Lee, E. R.;
Loomba, D.;
Matthews, J. A. J.;
Miller, E. H.;
Monte, A.;
Murphy, A. StJ.;
Paling, S. M.;
Phan, N.;
Pipe, M.;
Robinson, M.;
Sadler, S. W.;
Scarff, A.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Telfer, S.;
Walker, D.;
Warner, D.;
Yuriev, L.
Submitted: 2014-07-15, last modified: 2014-08-25
Radon gas emanating from materials is of interest in environmental science
and also a major concern in rare event non-accelerator particle physics
experiments such as dark matter and double beta decay searches, where it is a
major source of background. Notable for dark matter experiments is the
production of radon progeny recoils (RPRs), the low energy (~100 keV) recoils
of radon daughter isotopes, which can mimic the signal expected from WIMP
interactions. Presented here are results of measurements of radon emanation
from detector materials in the 1 metre cubed DRIFT-II directional dark matter
gas time projection chamber experiment. Construction and operation of a radon
emanation facility for this work is described, along with an analysis to
continuously monitor DRIFT data for the presence of internal 222Rn and 218Po.
Applying this analysis to historical DRIFT data, we show how systematic
substitution of detector materials for alternatives, selected by this device
for low radon emanation, has resulted in a factor of ~10 reduction in internal
radon rates. Levels are found to be consistent with the sum from separate radon
emanation measurements of the internal materials and also with direct
measurement using an attached alpha spectrometer. The current DRIFT detector,
DRIFT-IId, is found to have sensitivity to 222Rn of 2.5 {\mu}Bq/l with current
analysis efficiency, potentially opening up DRIFT technology as a new tool for
sensitive radon assay of materials.
[6]
oai:arXiv.org:1404.2253 [pdf] - 934775
Background Assay and Rejection in DRIFT
Brack, Jeff;
Daw, Ed;
Dorofeev, Alexei;
Ezeribe, Anthony;
Gauvreau, Jean-Luc;
Gold, Michael;
Harton, John;
Lafler, Randy;
Lauer, Robert;
Lee, Eric R.;
Loomba, Dinesh;
Matthews, John;
Miller, Eric H.;
Monte, Alissa;
Murphy, Alex;
Paling, Sean;
Phan, Nguyen;
Sadler, Steve;
Scarff, Andrew;
Snowden-Ifft, Daniel;
Spooner, Neil;
Telfer, Sam;
Walker, Daniel;
Williams, Matt;
Yuriev, Leonid
Submitted: 2014-04-08
The DRIFT-IId dark matter detector is a m$^3$-scale low-pressure TPC with
directional sensitivity to WIMP-induced nuclear recoils. Its primary
backgrounds were due to alpha decays from contamination on the central cathode.
Efforts to reduce these backgrounds led to replacing the 20 \mu m wire central
cathode with one constructed from 0.9 \mu m aluminized mylar, which is almost
totally transparent to alpha particles. Detailed modeling of the nature and
origin of the remaining backgrounds led to an in-situ, ppt-sensitive assay of
alpha decay backgrounds from the central cathode. This led to further
improvements in the thin-film cathode resulting in over 2 orders of magnitude
reduction in backgrounds compared to the wire cathode. Finally, the addition of
O$_2$ to CS$_2$ gas was found to produce multiple species of electronegative
charge carriers, providing a method to determine the absolute position of
nuclear recoils and reject all known remaining backgrounds while retaining a
high efficiency for nuclear recoil detection.