Normalized to: Tanigawa, S.
[1]
oai:arXiv.org:1710.07301 [pdf] - 1648663
Size--luminosity relations and UV luminosity functions at $z=6-9$
simultaneously derived from the complete Hubble Frontier Fields data
Submitted: 2017-10-19, last modified: 2018-02-26
We construct $z\sim6-7$, 8, and 9 faint Lyman break galaxy samples (334, 61,
and 37 galaxies, respectively) with accurate size measurements with the
software $\texttt{glafic}$ from the complete Hubble Frontier Fields (FF)
cluster and parallel fields data. These are the largest samples hitherto and
reach down to the faint ends of recently obtained deep luminosity functions. At
faint magnitudes, however, these samples are highly incomplete for galaxies
with large sizes, implying that derivation of the luminosity function (LF)
sensitively depends on the intrinsic size--luminosity (RL) relation. We thus
conduct simultaneous maximum-likelihood estimation of LF and RL relation
parameters from the observed distribution of galaxies on the RL plane with help
of a completeness map as a function of size and luminosity. At $z\sim6-7$, we
find that the intrinsic RL relation expressed as $r_\textrm{e} \propto L^\beta$
has a notably steeper slope of $\beta=0.46^{+0.08}_{-0.09}$ than those at lower
redshifts, which in turn implies that the LF has a relatively shallow faint-end
slope of $\alpha=-1.86^{+0.17}_{-0.18}$. This steep $\beta$ can be reproduced
by a simple analytical model in which smaller galaxies have lower specific
angular momenta. The $\beta$ and $\alpha$ values for the $z\sim8$ and 9 samples
are consistent with those for $z\sim6-7$ but with larger errors. For all three
samples there is a large, positive covariance between $\beta$ and $\alpha$,
implying that the simultaneous determination of these two parameters is
important. We also provide new strong lens mass models of Abell S1063 and Abell
370 as well as updated mass models of Abell 2744 and MACS J0416.1$-$2403.
[3]
oai:arXiv.org:1509.00548 [pdf] - 1938094
Development of the photomultiplier tube readout system for the first
Large-Sized Telescope of the Cherenkov Telescope Array
Masuda, Shu;
Konno, Yusuke;
Barrio, Juan Abel;
Bigas, Oscar Blanch;
Delgado, Carlos;
Coromina, Lluís Freixas;
Gunji, Shuichi;
Hadasch, Daniela;
Hatanaka, Kenichiro;
Ikeno, Masahiro;
Laguna, Jose Maria Illa;
Inome, Yusuke;
Ishio, Kazuma;
Katagiri, Hideaki;
Kubo, Hidetoshi;
Martínez, Gustavo;
Mazin, Daniel;
Nakajima, Daisuke;
Nakamori, Takeshi;
Ohoka, Hideyuki;
Paoletti, Riccardo;
Ritt, Stefan;
Rugliancich, Andrea;
Saito, Takayuki;
Sulanke, Karl-Heinz;
Takeda, Junki;
Tanaka, Manobu;
Tanigawa, Shunsuke;
Tejedor, Luis Ángel;
Teshima, Masahiro;
Tsuchiya, Yugo;
Uchida, Tomohisa;
Yamamoto, Tokonatsu;
team, the LST
Submitted: 2015-09-01
The Cherenkov Telescope Array (CTA) is the next generation ground-based very
high energy gamma-ray observatory. The Large-Sized Telescope (LST) of CTA
targets 20 GeV -- 1 TeV gamma rays and has 1855 photomultiplier tubes (PMTs)
installed in the focal plane camera. With the 23 m mirror dish, the night sky
background (NSB) rate amounts to several hundreds MHz per pixel. In order to
record clean images of gamma-ray showers with minimal NSB contamination, a fast
sampling of the signal waveform is required so that the signal integration time
can be as short as the Cherenkov light flash duration (a few ns). We have
developed a readout board which samples waveforms of seven PMTs per board at a
GHz rate. Since a GHz FADC has a high power consumption, leading to large heat
dissipation, we adopted the analog memory ASIC "DRS4". The sampler has 1024
capacitors per channel and can sample the waveform at a GHz rate. Four channels
of a chip are cascaded to obtain deeper sampling depth with 4096 capacitors.
After a trigger is generated in a mezzanine on the board, the waveform stored
in the capacitor array is subsequently digitized with a low speed (33 MHz) ADC
and transferred via the FPGA-based Gigabit Ethernet to a data acquisition
system. Both a low power consumption (2.64 W per channel) and high speed
sampling with a bandwidth of $>$300 MHz have been achieved. In addition, in
order to increase the dynamic range of the readout we adopted a two gain system
achieving from 0.2 up to 2000 photoelectrons in total. We finalized the board
design for the first LST and proceeded to mass production. Performance of
produced boards are being checked with a series of quality control (QC) tests.
We report the readout board specifications and QC results.