Normalized to: Takei, D.
[1]
oai:arXiv.org:1503.03181 [pdf] - 1232012
X-ray Fading and Expansion in the "Miniature Supernova Remnant" of GK
Persei
Submitted: 2015-03-11
We report on a second epoch of Chandra X-ray imaging spectroscopy of the
spatially-resolved old nova remnant GK Persei. An ACIS-S3 observation of 97.4
ks was conducted in November 2013 after a lapse of 13.8 years from the last
visit in 2000. The X-ray emitting nebula appeared more faint and patchy
compared with the first epoch. The flux decline was particularly evident in
fainter regions and the mean decline was 30-40 % in the 0.5-1.2 keV energy
band. A typical expansion of the brightest part of the remnant was 1.9 arcsec,
which corresponds to an expansion rate of 0.14 arcsec yr^{-1}. The soft X-ray
spectra extracted from both the 2000 and 2013 data can be explained by a
non-equilibrium ionization collisional plasma model convolved with interstellar
absorption, though do not allow us to constrain the origin of the flux
evolution. The plasma temperature has not significantly evolved since the 2000
epoch and we conclude that the fading of the X-ray emission is due largely to
expansion. This implies that recent expansion has been into a lower density
medium, a scenario that is qualitatively consistent with the structure of the
circumstellar environment photographed soon after the initial explosion more
than a century ago. Fainter areas are fading more quickly than brighter areas,
indicating that they are fainter because of a lower ambient medium density and
consequently more rapid expansion.
[2]
oai:arXiv.org:1408.4556 [pdf] - 1447618
Development and Performance of Kyoto's X-ray Astronomical SOI pixel
(SOIPIX) sensor
Tsuru, Takeshi G.;
Matsumura, Hideaki;
Takeda, Ayaki;
Tanaka, Takaaki;
Nakashima, Shinya;
Arai, Yasuo;
Mori, Koji;
Takenaka, Ryota;
Nishioka, Yusuke;
Kohmura, Takayoshi;
Hatsui, Takaki;
Kameshima, Takashi;
Ozaki, Kyosuke;
Kohmura, Yoshiki;
Wagai, Tatsuya;
Takei, Dai;
Kawahito, Shoji;
Kagawa, Keiichiro;
Yasutomi, Keita;
Kamehama, Hiroki;
Shrestha, Sumeet
Submitted: 2014-08-20
We have been developing monolithic active pixel sensors, known as Kyoto's
X-ray SOIPIXs, based on the CMOS SOI (silicon-on-insulator) technology for
next-generation X-ray astronomy satellites. The event trigger output function
implemented in each pixel offers microsecond time resolution and enables
reduction of the non-X-ray background that dominates the high X-ray energy band
above 5--10 keV. A fully depleted SOI with a thick depletion layer and back
illumination offers wide band coverage of 0.3--40 keV. Here, we report recent
progress in the X-ray SOIPIX development. In this study, we achieved an energy
resolution of 300~eV (FWHM) at 6~keV and a read-out noise of 33~e- (rms) in the
frame readout mode, which allows us to clearly resolve Mn-K$\alpha$ and
K$\beta$. Moreover, we produced a fully depleted layer with a thickness of
$500~{\rm \mu m}$. The event-driven readout mode has already been successfully
demonstrated.
[3]
oai:arXiv.org:1401.7348 [pdf] - 777703
A magnetic accretion switch in pre-cataclysmic binaries?
Submitted: 2014-01-28
We have investigated the mass accretion rate implied by published surface
abundances of Si and C in the white dwarf component of the 3.62 hr period
pre-cataclysmic binary and planet host candidate QS Vir (DA+M2-4). Diffusion
timescales for gravitational settling imply $\dot{M} \sim 10^{-16}M_\odot$
yr$^{-1}$ for the 1999 epoch of the observations, which is three orders of
magnitude lower than measured from a 2006 {\it XMM-Newton} observation. This is
the first time that large accretion rate variations have been seen in a
detached pre-CV. A third body in a 14 yr eccentric orbit suggested in a recent
eclipse timing study is too distant to perturb the central binary sufficiently
to influence accretion. A hypothetical coronal mass ejection just prior to the
{\it XMM-Newton} observation might explain the higher accretion rate, but the
implied size and frequency of such events appear too great. We suggest
accretion is most likely modulated by a magnetic cycle on the secondary acting
as a wind "accretion switch", a mechanism that can be tested by X-ray and
ultraviolet monitoring. If so, QS Vir and similar pre-CVs could provide
powerful insights into hitherto inscrutable cataclysmic variable and M dwarf
magnetospheres, and mass and angular momentum loss rates.
[4]
oai:arXiv.org:1311.5969 [pdf] - 1201834
X-ray Development of the Classical Nova V2672 Ophiuchi with Suzaku
Submitted: 2013-11-23
We report the Suzaku detection of a rapid flare-like X-ray flux amplification
early in the development of the classical nova V2672 Ophiuchi. Two
target-of-opportunity ~25 ks X-ray observations were made 12 and 22 days after
the outburst. The flux amplification was found in the latter half of day 12.
Time-sliced spectra are characterized by a growing supersoft excess with
edge-like structures and a relatively stable optically-thin thermal component
with Ka emission lines from highly ionized Si. The observed spectral evolution
is consistent with a model that has a time development of circumstellar
absorption, for which we obtain the decline rate of ~10-40 % in a time scale of
0.2 d on day 12. Such a rapid drop of absorption and short-term flux
variability on day 12 suggest inhomogeneous ejecta with dense blobs/holes in
the line of sight. Then on day 22 the fluxes of both supersoft and thin-thermal
plasma components become significantly fainter. Based on the serendipitous
results we discuss the nature of this source in the context of both short- and
long-term X-ray behavior.
[5]
oai:arXiv.org:1303.5766 [pdf] - 1165487
X-ray Eclipse Diagnosis of the Evolving Mass Loss in the Recurrent Nova
U Scorpii 2010
Submitted: 2013-03-22
We report the Suzaku detection of the earliest X-ray eclipse seen in the
recurrent nova U Scorpii 2010. A target-of-opportunity observation 15 days
after the outburst found a 27+/-5% dimming in the 0.2-1.0 keV energy band at
the predicted center of an eclipse. In comparison with the X-ray eclipse depths
seen at two later epochs by XMM-Newton, the source region shrank by about
10-20% between days 15 and 35 after the outburst. The X-ray eclipses appear to
be deeper than or similar to contemporaneous optical eclipses, suggesting the
X-ray and optical source region extents are comparable on day 15. We raise the
possibility of the energy dependency in the photon escape regions, and that
this would be a result of the supersoft X-ray opacity being higher than the
Thomson scattering optical opacity at the photosphere due to bound-free
transitions in abundant metals that are not fully ionized. Assuming a
spherically symmetric explosion model, we constrain the mass-loss rate as a
function of time. For a ratio of actual to Thomson opacity of 10-100 in
supersoft X-rays, we find a total ejecta mass of about 10^{-7}-10^{-6}
M_{\odot}.
[6]
oai:arXiv.org:1211.0276 [pdf] - 1157451
Discovery of X-ray Emission in the Old Classical Nova DK Lacertae
Submitted: 2012-11-01
We report the discovery of X-ray emission at the position of the old
classical nova DK Lacertae using the Swift satellite. Three observations were
conducted using the X-ray telescope 62 years after the discovery of the nova,
yielding 46 source signals in an exposure time of 4.8 ks. A
background-subtracted count rate was 9+/-2x10^{-3} counts s^{-1}, corresponding
to a detection significance level of 5-sigma. The X-ray spectrum was
characterized by a continuum extending up to about 7 keV, which can be modeled
by a power-law component with a photon index of 1.4--5.6, or by a thermal
bremsstrahlung component with a temperature of 0.7--13.3 keV, convolved with
interstellar absorption with an equivalent hydrogen column density of
0.3--2.4x10^{22} cm^{-2}. Assuming a distance of 3900 pc to the source, the
luminosity was 10^{32}--10^{34} ergs s^{-1} in the 0.3--10 keV energy band. The
origin of X-rays is considered to be either mass accretion on the white dwarf
or adiabatic shocks in nova ejecta, with the former appearing much more likely.
In either case, DK Lacertae represents a rare addition to the exclusive club of
X-ray emitting old novae.
[7]
oai:arXiv.org:0911.4233 [pdf] - 1018463
Beginning of the Super-Soft Phase of the Classical Nova V2491 Cygni
Submitted: 2009-11-22, last modified: 2012-11-01
We present the results of soft X-ray studies of the classical nova V2491
Cygni using the Suzaku observatory. On day 29 after outburst, a soft X-ray
component with a peak at ~0.5 keV has appeared, which is tantalising evidence
for the beginning of the super-soft X-ray emission phase. We show that an
absorbed blackbody model can describe the observed spectra, yielding a
temperature of 57 eV, neutral hydrogen column density of 2x10^{21} cm^{-2}, and
a bolometric luminosity of ~10^{36} erg s^{-1}. However, at the same time, we
also found a good fit with an absorbed thin-thermal plasma model, yielding a
temperature of 0.1 keV, neutral hydrogen column density of 4x10^{21} cm^{-2},
and a volume emission measure of ~10^{58} cm^{-3}. Owing to low spectral
resolution and low signal-to-noise ratio below 0.6 keV, the statistical
parameter uncertainties are large, but the ambiguity of the two very different
models demonstrates that the systematic errors are the main point of concern.
The thin-thermal plasma model implies that the soft emission originates from
optically thin ejecta, while the blackbody model suggests that we are seeing
optically thick emission from the white dwarf.
[8]
oai:arXiv.org:1102.2436 [pdf] - 1052063
X-ray Study of Rekindled Accretion in the Classical Nova V2491 Cygni
Submitted: 2011-02-11
We conducted an X-ray spectroscopic study of the classical nova V2491 Cygni
using our target-of-opportunity observation data with the Suzaku and XMM-Newton
satellites as well as archived data with the Swift satellite. Medium-resolution
(R~10-50) spectra were obtained using the X-ray CCD spectrometers at several
post-nova epochs on days 9, 29, 40, 50, and 60-150 in addition to a pre-nova
interval between days -322 and -100 all relative to the time when the classical
nova was spotted. We found remarkable changes in the time series of the
spectra: (a) In the pre-nova phase and on day 9, the 6.7 keV emission line from
Fe XXV was significantly detected. (b) On day 29, no such emission line was
found. (c) On day 40, the 6.7 keV emission line emerged again. (d) On days 50
and 60-150, three emission lines at 6.4, 6.7, and 7.0 keV respectively from
quasi-neutral Fe, Fe XXV, and Fe XXVI were found. Statistically significant
changes of the Fe K line intensities were confirmed between day 29 and 50.
Based on these phenomena, we conclude that (1) the post-nova evolution can be
divided into two different phases, (2) ejecta is responsible for the X-ray
emission in the earlier phase, while rekindled accretion is for the later
phase, and (3) the accretion process is considered to be reestablished as early
as day 50 when the quasi-neutral Fe emission line emerged, which is a common
signature of accretion from magnetic cataclysmic variables.
[9]
oai:arXiv.org:0904.1693 [pdf] - 23253
Suzaku Detection of Super-hard X-ray Emission from the Classical Nova
V2491 Cygni
Submitted: 2009-04-10
We report the detection of super-hard (>10 keV) X-ray emission extending up
to 70 keV from the classical nova V2491 Cygni using the Suzaku observatory. We
conducted two ~20 ks target-of-opportunity observations 9 and 29 days after the
outburst on 2008 April 11, yielding wide energy range spectra by combining the
X-ray Imaging Spectrometer and the Hard X-ray Detector. On day 9, a spectrum
was obtained at 1.0-70 keV with the Fe XXV K\alpha line feature and a very flat
continuum, which is explained by thermal plasma with a 3 keV temperature and
power-law emission with a photon index of 0.1 attenuated by a heavy extinction
of 1.4x10^{23} cm^{-2}. The 15-70 keV luminosity at 10.5 kpc is 6x10^{35} ergs
s^{-1}. The super-hard emission was not present on day 29. This is the highest
energy at which X-rays have been detected from a classical nova. We argue a
non-thermal origin for the emission, which suggests the presence of accelerated
charged particles in the nova explosion.
[10]
oai:arXiv.org:0902.2199 [pdf] - 21308
Swift X-ray and UV monitoring of the Classical Nova V458 Vul (Nova Vul
2007)
Ness, J. -U.;
Drake, J. J.;
Beardmore, A. P.;
Boyd, D.;
Bode, M. F.;
Brady, S.;
Evans, P. A.;
Gaensicke, B. T.;
Kitamoto, S.;
Knigge, C.;
Miller, I.;
Osborne, J. P.;
Page, K. L.;
Rodriguez-Gil, P.;
Schwarz, G.;
Staels, B.;
Steeghs, D.;
Takei, D.;
Tsujimoto, M.;
Wesson, R.;
Zijlstra, A.
Submitted: 2009-02-12
We describe the highly variable X-ray and UV emission of V458 Vul (Nova Vul
2007), observed by Swift between 1 and 422 days after outburst. Initially
bright only in the UV, V458 Vul became a variable hard X-ray source due to
optically thin thermal emission at kT=0.64 keV with an X-ray band unabsorbed
luminosity of 2.3x10^{34} erg s^{-1} during days 71-140. The X-ray spectrum at
this time requires a low Fe abundance (0.2^{+0.3}_{-0.1} solar), consistent
with a Suzaku measurement around the same time. On day 315 we find a new X-ray
spectral component which can be described by a blackbody with temperature of
kT=23^{+9}_{-5} eV, while the previous hard X-ray component has declined by a
factor of 3.8. The spectrum of this soft X-ray component resembles those
typically seen in the class of supersoft sources (SSS) which suggests that the
nova ejecta were starting to clear and/or that the WD photosphere is shrinking
to the point at which its thermal emission reaches into the X-ray band. We find
a high degree of variability in the soft component with a flare rising by an
order of magnitude in count rate in 0.2 days. In the following observations on
days 342.4-383.6, the soft component was not seen, only to emerge again on day
397. The hard component continued to evolve, and we found an anticorrelation
between the hard X-ray emission and the UV emission, yielding a Spearman rank
probability of 97%. After day 397, the hard component was still present, was
variable, and continued to fade at an extremely slow rate but could not be
analysed owing to pile up contamination from the bright SSS component.
[11]
oai:arXiv.org:0810.3077 [pdf] - 1000996
X-Ray Spectroscopy of the Classical Nova V458 Vulpeculae with Suzaku
Submitted: 2008-10-17
We conducted a target of opportunity X-ray observation of the classical nova
V458 Vulpeculae 88 days after the explosion using the Suzaku satellite. With a
20 ks exposure, the X-ray Imaging Spectrometer detected X-ray emission
significantly harder than typical super-soft source emission. The X-ray
spectrum shows K lines from N, Ne, Mg, Si, and S, and L-series emission from Fe
in highly ionized states. The spectrum can be described by a single temperature
(0.64 keV) thin thermal plasma model in collisional equilibrium with a
hydrogen-equivalent extinction column density of ~3e21/cm2, a flux of ~1e-12
erg/s/cm2, and a luminosity of ~6e34 erg/s in the 0.3-3.0 keV band at an
assumed distance of 13 kpc. We found a hint of an enhancement of N and
deficiencies of O and Fe relative to other metals. The observed X-ray
properties can be interpreted as the emission arising from shocks of ejecta
from an ONe-type nova.
[12]
oai:arXiv.org:0810.0873 [pdf] - 1000970
New CTI Correction Method for the Spaced-Row Charge Injection of the
Suzaku X-Ray Imaging Spectrometer
Uchiyama, Hideki;
Ozawa, Midori;
Matsumoto, Hironori;
Tsuru, Takeshi Go;
Koyama, Katsuji;
Kimura, Masashi;
Uchida, Hiroyuki;
Nakajima, Hiroshi;
Hayashida, Kiyoshi;
Tsunemi, Hiroshi;
Mori, Hideyuki;
Bamba, Aya;
Ozaki, Masanobu;
Dotani, Tadayasu;
Takei, Dai;
Murakami, Hiroshi;
Mori, Koji;
Ishisaki, Yoshitaka;
Kohmura, Takayoshi;
Prigozhin, Gregory;
Kissel, Steve;
Miller, Eric;
LaMarr, Beverly;
Bautz, Marshall
Submitted: 2008-10-06
The charge transfer inefficiency (CTI) of the X-ray CCDs on board the Suzaku
satellite (X-ray Imaging Spectrometers; XIS) has increased since the launch due
to radiation damage, and the energy resolution has been degraded. To improve
the CTI, we have applied a spaced-row charge injection (SCI) technique to the
XIS in orbit; by injecting charges into CCD rows periodically, the CTI is
actively decreased. The CTI in the SCI mode depends on the distance between a
signal charge and a preceding injected row, and the pulse height shows periodic
positional variations. Using in-flight data of onboard calibration sources and
of the strong iron line from the Perseus cluster of galaxies, we studied the
variation in detail. We developed a new method to correct the variation. By
applying the new method, the energy resolution (FWHM) at 5.9 keV at March 2008
is ~155 eV for the front-illuminated CCDs and ~175 eV for the back-illuminated
CCD.
[13]
oai:arXiv.org:0801.0039 [pdf] - 8532
Suzaku Observation of AXP 1E 1841-045 in SNR Kes 73
Morii, M.;
Kitamoto, S.;
Shibazaki, N.;
Takei, D.;
Kawai, N.;
Arimoto, M.;
Ueno, M.;
Terada, Y.;
Kohmura, T.;
Yamauchi, S.
Submitted: 2007-12-29
Anomalous X-ray pulsars (AXPs) are thought to be magnetars, which are neutron
stars with ultra strong magnetic field of $10^{14}$-- $10^{15}$ G. Their energy
spectra below $\sim$10 keV are modeled well by two components consisting of a
blackbody (BB) ($\sim$0.4 keV) and rather steep power-law (POW) function
(photon index $\sim$2-4). Kuiper et al.(2004) discovered hard X-ray component
above $\sim$10 keV from some AXPs. Here, we present the Suzaku observation of
the AXP 1E 1841-045 at the center of supernova remnant Kes 73. By this
observation, we could analyze the spectrum from 0.4 to 50 keV at the same time.
Then, we could test whether the spectral model above was valid or not in this
wide energy range. We found that there were residual in the spectral fits when
fit by the model of BB + POW. Fits were improved by adding another BB or POW
component. But the meaning of each component became ambiguous in the
phase-resolved spectroscopy. Alternatively we found that NPEX model fit well
for both phase-averaged spectrum and phase-resolved spectra. In this case, the
photon indices were constant during all phase, and spectral variation seemed to
be very clear. This fact suggests somewhat fundamental meaning for the emission
from magnetars.
[14]
oai:arXiv.org:0706.0278 [pdf] - 1529988
Detection of a Rare Supersoft Outburst Event during a Suzaku Observation
of 1E0102.2-7219
Submitted: 2007-06-02
We report the detection of a transient X-ray source toward the Small
Magellanic Cloud (SMC) using the X-ray Imaging Spectrometer (XIS) onboard the
Suzaku telescope. The source was detected at the edge of the XIS image during a
routine observation of the calibration source 1E 0102.2-7219, a supernova
remnant in the SMC. We constrained the source position using ray-tracing
simulations. No such transient source was found at the position in the other
Suzaku observations nor in all the available archived images of other X-ray
missions for the last ~28 years. The XIS spectrum can be explained by a single
blackbody with a temperature of ~72 eV, and an interstellar extinction of
~4.9x10^{20} H atoms cm^{-2} consistent with the value to the SMC. An
additional absorption edge at ~0.74 keV was also confirmed, which is presumably
due to the absorption by helium-like oxygen ions. Assuming that the source is
at the distance of the SMC, the X-ray luminosity in the 0.2-2.0 keV band is
~10^{37} erg s^{-1} and the radius of the source is ~10^{8} cm. The XIS light
curve shows about a two-fold decline in X-ray flux during the 24 ks
observation. Together with the archived data, the X-ray flux in the burst is at
least three orders of magnitude brighter than the undetected quiescent level.
All these properties are often seen among supersoft sources (SSSs). We conclude
that the transient source is another example of SSS in the SMC.