Normalized to: Takahashi, D.
[1]
oai:arXiv.org:1711.09850 [pdf] - 1644756
Non-minimal quartic inflation in classically conformal U(1)$_X$ extended
Standard Model
Submitted: 2017-11-27, last modified: 2018-02-12
We propose quartic inflation with non-minimal gravitational coupling in the
context of the classically conformal U(1)_X extension of the SM. In this model,
the U(1)_X gauge symmetry is radiatively broken through the Coleman-Weinberg
(CW) mechanism, by which the U(1)_X gauge boson (Z' boson) and the right-handed
neutrinos (RHNs) acquire their masses. We consider their masses in the range of
O(10 GeV)-O(10 TeV), which are accessible to high energy collider experiments.
The radiative U(1)_X gauge symmetry breaking also generates a negative mass
squared for the SM Higgs doublet, and the electroweak symmetry breaking occurs
subsequently. We identify the U(1)_X Higgs field with inflaton and calculate
the inflationary predictions. Due to the CW mechanism, the inflaton quartic
coupling during inflation, which determines the inflationary predictions, is
correlated to the U(1)_X gauge coupling. With this correlation, we investigate
complementarities between the inflationary predictions and the current
constraint from the Z' boson resonance search at the LHC Run-2 as well as the
prospect of the search for the Z' boson and the RHNs at the future collider
experiments. The radiative U(1)_X gauge symmetry breaking also generates a
negative mass squared for the SM Higgs doublet, and the electroweak symmetry
breaking occurs subsequently. We identify the U(1)_X Higgs field with inflaton
and calculate the inflationary predictions. Due to the Coleman-Weinberg
mechanism, the inflaton quartic coupling during inflation, which determines the
inflationary predictions, is correlated to the U(1)_X gauge coupling. With this
correlation, we investigate complementarities between the inflationary
predictions and the current constraint from the Z' boson resonance search at
the LHC Run-2 as well as the prospect of the search for the Z' boson and the
RHNs at the future collider experiments.
[2]
oai:arXiv.org:astro-ph/0311067 [pdf] - 1233264
Design and Performance of the Wide-Field X-Ray Monitor on Board the
High-Energy Transient Explorer 2
Shirasaki, Y.;
Kawai, N.;
Yoshida, A.;
Matsuoka, M.;
Tamagawa, T.;
Torii, K.;
Sakamoto, T.;
Suzuki, M.;
Urata, Y.;
Sato, R.;
Nakagawa, Y.;
Takahashi, D.;
Fenimore, E. E.;
Galassi, M.;
Lamb, D. Q.;
Graziani, C.;
Donaghy, T. Q.;
Vanderspek, R.;
Yamauchi, M.;
Takagishi, K.;
Hatsukade, I.
Submitted: 2003-11-03
The Wide-field X-ray Monitor (WXM) is one of the scientific instruments
carried on the High Energy Transient Explorer 2 (HETE-2) satellite launched on
2000 October 9. HETE-2 is an international mission consisting of a small
satellite dedicated to provide broad-band observations and accurate
localizations of gamma-ray bursts (GRBs). A unique feature of this mission is
its capability to determine and transmit GRB coordinates in almost real-time
through the burst alert network. The WXM consists of three elements: four
identical Xe-filled one-dimensional position-sensitive proportional counters,
two sets of one-dimensional coded apertures, and the main electronics. The WXM
counters are sensitive to X-rays between 2 keV and 25 keV within a
field-of-view of about 1.5 sr, with a total detector area of about 350 cm$^2$.
The in-flight triggering and localization capability can produce a real-time
GRB location of several to 30 arcmin accuracy, with a limiting sensitivity of
$10^{-7}$ erg cm$^{-2}$. In this report, the details of the mechanical
structure, electronics, on-board software, ground and in-flight calibration,
and in-flight performance of the WXM are discussed.
[3]
oai:arXiv.org:astro-ph/0210427 [pdf] - 52465
Astrometric Calibration and Estimate of the Systematic Error in WXM
Localizations Obtained by the Chicago Bayesian Method
Graziani, C.;
Shirasaki, Y.;
Donaghy, T.;
Fenimore, E.;
Galassi, M.;
Kawai, N.;
Lamb, D. Q.;
Sakamoto, T.;
Takahashi, D.;
Tamagawa, T.;
Tavenner, T.;
Torii, K.;
Yoshida, A.;
Vanderspek, R.
Submitted: 2002-10-18
WXM gives GRB localizations in instrument coordinates. WXM localizations must
be converted to celestial coordinates using spacecraft aspect information
obtained by the optical cameras on HETE. We must therefore accurately determine
the alignment of the WXM boresight with respect to that of the optical cameras,
in order to accurately determine the celestial coordinates of WXM burst
locations. We use a seven-parameter model that treats as free parameters the
three Euler angles of a pure rotation, two horizontal shifts of the
coded-aperture masks with respect to the detectors, and the heights of the
masks above the two detectors. We determine the alignment by fitting the model
to a set of 252 WXM localizations of Sco X-1 obtained between 23 April and 28
June 2001. We estimate the systematic error in WXM GRB locations by comparing
the actual and the calculated locations of Sco X-1. We find that the systematic
error corresponding to a 68.3% confidence region is 1.7$'$, and the systematic
error corresponding to a 90% confidence region is 2.4$'$. We find that this
astrometric solution also provides a satisfactory fit to an independent sample
of SGR and XRB events. These results are consistent with the astrometric
calibration and the systematic error in WXM localizations derived independently
using the RIKEN localization method.