Normalized to: Takada, S.
[1]
oai:arXiv.org:1806.07665 [pdf] - 1732736
Impact cratering mechanics: A forward approach to predicting ejecta
velocity distribution and transient crater radii
Submitted: 2018-06-20
Impact craters are among the most prominent topographic features on planetary
bodies. Crater scaling laws allow us to extract information about the impact
histories on the host bodies. The pi-group scaling laws have been constructed
based on the point-source approximation, dimensional analysis, and the results
from impact experiments. Recent impact experiments, however, demonstrated that
the scaling parameters themselves exhibits complex behavior against the change
in the impact conditions and target properties. Here, we propose an
alternative, fully analytical method to predict impact outcomes based on impact
cratering mechanics. This approach is based on the Maxwell Z-model and the
residual velocity. We present analytical expressions of (1) the proportionality
relation between the ejection velocity and the ejection position, (2) the
radius of a growing crater as a function of time, and (3) the transient crater
radii. Since we focused on obtaining analytical solutions, a number of
simplifications are employed. Due to the simplifications in the strength model,
the accuracy of the prediction in the strength-dominated regime is relatively
low. Our model reproduces the power-law behavior of the ejecta velocity
distribution and the approximate time variation of a growing crater. The
predicted radii under typical impact conditions mostly converge to a region
between the two typical scaling lines by the pi-group scaling laws, strongly
supporting the notion that the new method is one of the simplest ways to
predict impact outcomes, as it provides analytical solutions. Our model could
serve as a quick-look tool to estimate the impact outcome under a given set of
conditions, and it might provide new insights into the nature of impact
excavation processes.
[2]
oai:arXiv.org:1801.06987 [pdf] - 1698011
The LiteBIRD Satellite Mission - Sub-Kelvin Instrument
Suzuki, A.;
Ade, P. A. R.;
Akiba, Y.;
Alonso, D.;
Arnold, K.;
Aumont, J.;
Baccigalupi, C.;
Barron, D.;
Basak, S.;
Beckman, S.;
Borrill, J.;
Boulanger, F.;
Bucher, M.;
Calabrese, E.;
Chinone, Y.;
Cho, H-M.;
Cukierman, A.;
Curtis, D. W.;
de Haan, T.;
Dobbs, M.;
Dominjon, A.;
Dotani, T.;
Duband, L.;
Ducout, A.;
Dunkley, J.;
Duval, J. M.;
Elleflot, T.;
Eriksen, H. K.;
Errard, J.;
Fischer, J.;
Fujino, T.;
Funaki, T.;
Fuskeland, U.;
Ganga, K.;
Goeckner-Wald, N.;
Grain, J.;
Halverson, N. W.;
Hamada, T.;
Hasebe, T.;
Hasegawa, M.;
Hattori, K.;
Hattori, M.;
Hayes, L.;
Hazumi, M.;
Hidehira, N.;
Hill, C. A.;
Hilton, G.;
Hubmayr, J.;
Ichiki, K.;
Iida, T.;
Imada, H.;
Inoue, M.;
Inoue, Y.;
D., K.;
Ishino, H.;
Jeong, O.;
Kanai, H.;
Kaneko, D.;
Kashima, S.;
Katayama, N.;
Kawasaki, T.;
Kernasovskiy, S. A.;
Keskitalo, R.;
Kibayashi, A.;
Kida, Y.;
Kimura, K.;
Kisner, T.;
Kohri, K.;
Komatsu, E.;
Komatsu, K.;
Kuo, C. L.;
Kurinsky, N. A.;
Kusaka, A.;
Lazarian, A.;
Lee, A. T.;
Li, D.;
Linder, E.;
Maffei, B.;
Mangilli, A.;
Maki, M.;
Matsumura, T.;
Matsuura, S.;
Meilhan, D.;
Mima, S.;
Minami, Y.;
Mitsuda, K.;
Montier, L.;
Nagai, M.;
Nagasaki, T.;
Nagata, R.;
Nakajima, M.;
Nakamura, S.;
Namikawa, T.;
Naruse, M.;
Nishino, H.;
Nitta, T.;
Noguchi, T.;
Ogawa, H.;
Oguri, S.;
Okada, N.;
Okamoto, A.;
Okamura, T.;
Otani, C.;
Patanchon, G.;
Pisano, G.;
Rebeiz, G.;
Remazeilles, M.;
Richards, P. L.;
Sakai, S.;
Sakurai, Y.;
Sato, Y.;
Sato, N.;
Sawada, M.;
Segawa, Y.;
Sekimoto, Y.;
Seljak, U.;
Sherwin, B. D.;
Shimizu, T.;
Shinozaki, K.;
Stompor, R.;
Sugai, H.;
Sugita, H.;
Suzuki, J.;
Tajima, O.;
Takada, S.;
Takaku, R.;
Takakura, S.;
Takatori, S.;
Tanabe, D.;
Taylor, E.;
Thompson, K. L.;
Thorne, B.;
Tomaru, T.;
Tomida, T.;
Tomita, N.;
Tristram, M.;
Tucker, C.;
Turin, P.;
Tsujimoto, M.;
Uozumi, S.;
Utsunomiya, S.;
Uzawa, Y.;
Vansyngel, F.;
Wehus, I. K.;
Westbrook, B.;
Willer, M.;
Whitehorn, N.;
Yamada, Y.;
Yamamoto, R.;
Yamasaki, N.;
Yamashita, T.;
Yoshida, M.
Submitted: 2018-01-22, last modified: 2018-03-15
Inflation is the leading theory of the first instant of the universe.
Inflation, which postulates that the universe underwent a period of rapid
expansion an instant after its birth, provides convincing explanation for
cosmological observations. Recent advancements in detector technology have
opened opportunities to explore primordial gravitational waves generated by the
inflation through B-mode (divergent-free) polarization pattern embedded in the
Cosmic Microwave Background anisotropies. If detected, these signals would
provide strong evidence for inflation, point to the correct model for
inflation, and open a window to physics at ultra-high energies.
LiteBIRD is a satellite mission with a goal of detecting
degree-and-larger-angular-scale B-mode polarization. LiteBIRD will observe at
the second Lagrange point with a 400 mm diameter telescope and 2,622 detectors.
It will survey the entire sky with 15 frequency bands from 40 to 400 GHz to
measure and subtract foregrounds.
The U.S. LiteBIRD team is proposing to deliver sub-Kelvin instruments that
include detectors and readout electronics. A lenslet-coupled sinuous antenna
array will cover low-frequency bands (40 GHz to 235 GHz) with four frequency
arrangements of trichroic pixels. An orthomode-transducer-coupled corrugated
horn array will cover high-frequency bands (280 GHz to 402 GHz) with three
types of single frequency detectors. The detectors will be made with Transition
Edge Sensor (TES) bolometers cooled to a 100 milli-Kelvin base temperature by
an adiabatic demagnetization refrigerator.The TES bolometers will be read out
using digital frequency multiplexing with Superconducting QUantum Interference
Device (SQUID) amplifiers. Up to 78 bolometers will be multiplexed with a
single SQUID amplidier.
We report on the sub-Kelvin instrument design and ongoing developments for
the LiteBIRD mission.
[3]
oai:arXiv.org:1801.01653 [pdf] - 1637640
ALMA reveals molecular cloud N55 in the Large Magellanic Cloud as a site
of massive star formation
Naslim, N;
Tokuda, K.;
Onishi, T.;
Kemper, F.;
Wong, T.;
Morata, O.;
Takada, S.;
Harada, R.;
Kawamura, A.;
Saigo, K.;
Indebetouw, R.;
Madden, S. C.;
Hony, S.;
Meixner, M.
Submitted: 2018-01-05
We present the molecular cloud properties of N55 in the Large Magellanic
Cloud using $^{12}$CO(1-0) and $^{13}$CO(1-0) observations obtained with
Atacama Large Millimeter Array. We have done a detailed study of molecular gas
properties, to understand how the cloud properties of N55 differ from Galactic
clouds. Most CO emission appears clumpy in N55, and molecular cores that have
YSOs show larger linewidths and masses. The massive clumps are associated with
high and intermediate mass YSOs. The clump masses are determined by local
thermodynamic equilibrium and virial analysis of the $^{12}$CO and $^{13}$CO
emissions. These mass estimates lead to the conclusion that, (a) the clumps are
in self-gravitational virial equilibrium, and (b) the $^{12}$CO(1-0)-to-H$_2$
conversion factor, X$_{\rm CO}$, is 6.5$\times$10$^{20}$cm$^{-2}$(K km
s$^{-1}$)$^{-1}$. This CO-to-H$_2$ conversion factor for N55 clumps is measured
at a spatial scale of $\sim$0.67 pc, which is about two times higher than the
X$_{\rm CO}$ value of Orion cloud at a similar spatial scale. The core mass
function of N55 clearly show a turnover below 200M$_{\odot}$, separating the
low-mass end from the high-mass end. The low-mass end of the $^{12}$CO mass
spectrum is fitted with a power law of index 0.5$\pm$0.1, while for $^{13}$CO
it is fitted with a power law index 0.6$\pm$0.2. In the high-mass end, the core
mass spectrum is fitted with a power index of 2.0$\pm$0.3 for $^{12}$CO, and
with 2.5$\pm$0.4 for $^{13}$CO. This power-law behavior of the core mass
function in N55 is consistent with many Galactic clouds.
[4]
oai:arXiv.org:1712.00148 [pdf] - 2127370
Construction of KAGRA: an Underground Gravitational Wave Observatory
Akutsu, T.;
Ando, M.;
Araki, S.;
Araya, A.;
Arima, T.;
Aritomi, N.;
Asada, H.;
Aso, Y.;
Atsuta, S.;
Awai, K.;
Baiotti, L.;
Barton, M. A.;
Chen, D.;
Cho, K.;
Craig, K.;
DeSalvo, R.;
Doi, K.;
Eda, K.;
Enomoto, Y.;
Flaminio, R.;
Fujibayashi, S.;
Fujii, Y.;
Fujimoto, M. -K.;
Fukushima, M.;
Furuhata, T.;
Hagiwara, A.;
Haino, S.;
Harita, S.;
Hasegawa, K.;
Hasegawa, M.;
Hashino, K.;
Hayama, K.;
Hirata, N.;
Hirose, E.;
Ikenoue, B.;
Inoue, Y.;
Ioka, K.;
Ishizaki, H.;
Itoh, Y.;
Jia, D.;
Kagawa, T.;
Kaji, T.;
Kajita, T.;
Kakizaki, M.;
Kakuhata, H.;
Kamiizumi, M.;
Kanbara, S.;
Kanda, N.;
Kanemura, S.;
Kaneyama, M.;
Kasuya, J.;
Kataoka, Y.;
Kawaguchi, K.;
Kawai, N.;
Kawamura, S.;
Kawazoe, F.;
Kim, C.;
Kim, J.;
Kim, J. C.;
Kim, W.;
Kimura, N.;
Kitaoka, Y.;
Kobayashi, K.;
Kojima, Y.;
Kokeyama, K.;
Komori, K.;
Kotake, K.;
Kubo, K.;
Kumar, R.;
Kume, T.;
Kuroda, K.;
Kuwahara, Y.;
Lee, H. -K.;
Lee, H. -W.;
Lin, C. -Y.;
Liu, Y.;
Majorana, E.;
Mano, S.;
Marchio, M.;
Matsui, T.;
Matsumoto, N.;
Matsushima, F.;
Michimura, Y.;
Mio, N.;
Miyakawa, O.;
Miyake, K.;
Miyamoto, A.;
Miyamoto, T.;
Miyo, K.;
Miyoki, S.;
Morii, W.;
Morisaki, S.;
Moriwaki, Y.;
Muraki, Y.;
Murakoshi, M.;
Musha, M.;
Nagano, K.;
Nagano, S.;
Nakamura, K.;
Nakamura, T.;
Nakano, H.;
Nakano, M.;
Nakano, M.;
Nakao, H.;
Nakao, K.;
Narikawa, T.;
Ni, W. -T.;
Nonomura, T.;
Obuchi, Y.;
Oh, J. J.;
Oh, S. -H.;
Ohashi, M.;
Ohishi, N.;
Ohkawa, M.;
Ohmae, N.;
Okino, K.;
Okutomi, K.;
Ono, K.;
Ono, Y.;
Oohara, K.;
Ota, S.;
Park, J.;
Arellano, F. E. Peña;
Pinto, I. M.;
Principe, M.;
Sago, N.;
Saijo, M.;
Saito, T.;
Saito, Y.;
Saitou, S.;
Sakai, K.;
Sakakibara, Y.;
Sasaki, Y.;
Sato, S.;
Sato, T.;
Sato, Y.;
Sekiguchi, T.;
Sekiguchi, Y.;
Shibata, M.;
Shiga, K.;
Shikano, Y.;
Shimoda, T.;
Shinkai, H.;
Shoda, A.;
Someya, N.;
Somiya, K.;
Son, E. J.;
Starecki, T.;
Suemasa, A.;
Sugimoto, Y.;
Susa, Y.;
Suwabe, H.;
Suzuki, T.;
Tachibana, Y.;
Tagoshi, H.;
Takada, S.;
Takahashi, H.;
Takahashi, R.;
Takamori, A.;
Takeda, H.;
Tanaka, H.;
Tanaka, K.;
Tanaka, T.;
Tatsumi, D.;
Telada, S.;
Tomaru, T.;
Tsubono, K.;
Tsuchida, S.;
Tsukada, L.;
Tsuzuki, T.;
Uchikata, N.;
Uchiyama, T.;
Uehara, T.;
Ueki, S.;
Ueno, K.;
Uraguchi, F.;
Ushiba, T.;
van Putten, M. H. P. M.;
Wada, S.;
Wakamatsu, T.;
Yaginuma, T.;
Yamamoto, K.;
Yamamoto, S.;
Yamamoto, T.;
Yano, K.;
Yokoyama, J.;
Yokozawa, T.;
Yoon, T. H.;
Yuzurihara, H.;
Zeidler, S.;
Zhao, Y.;
Zheng, L.;
Agatsuma, K.;
Akiyama, Y.;
Arai, N.;
Asano, M.;
Bertolini, A.;
Fujisawa, M.;
Goetz, R.;
Guscott, J.;
Hashimoto, Y.;
Hayashida, Y.;
Hennes, E.;
Hirai, K.;
Hirayama, T.;
Ishitsuka, H.;
Kato, J.;
Khalaidovski, A.;
Koike, S.;
Kumeta, A.;
Miener, T.;
Morioka, M.;
Mueller, C. L.;
Narita, T.;
Oda, Y.;
Ogawa, T.;
Sekiguchi, T.;
Tamura, H.;
Tanner, D. B.;
Tokoku, C.;
Toritani, M.;
Utsuki, T.;
Uyeshima, M.;
Brand, J. van den;
van Heijningen, J.;
Yamaguchi, S.;
Yanagida, A.
Submitted: 2017-11-30, last modified: 2017-12-11
Major construction and initial-phase operation of a second-generation
gravitational-wave detector KAGRA has been completed. The entire 3-km detector
is installed underground in a mine in order to be isolated from background
seismic vibrations on the surface. This allows us to achieve a good sensitivity
at low frequencies and high stability of the detector. Bare-bones equipment for
the interferometer operation has been installed and the first test run was
accomplished in March and April of 2016 with a rather simple configuration. The
initial configuration of KAGRA is named {\it iKAGRA}. In this paper, we
summarize the construction of KAGRA, including the study of the advantages and
challenges of building an underground detector and the operation of the iKAGRA
interferometer together with the geophysics interferometer that has been
constructed in the same tunnel.
[5]
oai:arXiv.org:1608.03025 [pdf] - 1531238
POLARBEAR-2: an instrument for CMB polarization measurements
Inoue, Y.;
Ade, P.;
Akiba, Y.;
Aleman, C.;
Arnold, K.;
Baccigalupi, C.;
Barch, B.;
Barron, D.;
Bender, A.;
Boettger, D.;
Borrill, J.;
Chapman, S.;
Chinone, Y.;
Cukierman, A.;
de Haan, T.;
Dobbs, M. A.;
Ducout, A.;
Dunner, R.;
Elleflot, T.;
Errard, J.;
Fabbian, G.;
Feeney, S.;
Feng, C.;
Fuller, G.;
Gilbert, A. J.;
Goeckner-Wald, N.;
Groh, J.;
Hall, G.;
Halverson, N.;
Hamada, T.;
Hasegawa, M.;
Hattori, K.;
Hazumi, M.;
Hill, C.;
Holzapfel, W. L.;
Hori, Y.;
Howe, L.;
Irie, F.;
Jaehnig, G.;
Jaffe, A.;
Jeongh, O.;
Katayama, N.;
Kaufman, J. P.;
Kazemzadeh, K.;
Keating, B. G.;
Kermish, Z.;
Keskital, R.;
Kisner, T.;
Kusaka, A.;
Jeune, M. Le;
Lee, A. T.;
Leon, D.;
Linder, E. V.;
Lowry, L.;
Matsuda, F.;
Matsumura, T.;
Miller, N.;
Mizukami, K.;
Montgomery, J.;
Navaroli, M.;
Nishino, H.;
Paar, H.;
Peloton, J.;
Poletti, D.;
Puglisi, G.;
Raum, C. R.;
Rebeiz, G. M.;
Reichardt, C. L.;
Richards, P. L.;
Ross, C.;
Rotermund, K. M.;
Segaw, Y.;
Sherwin, B. D.;
Shirley, I.;
Siritanasak, P.;
Stebor, N.;
Suzuki, R. Stompor A.;
Tajima, O.;
Takada, S.;
Takatori, S.;
Teply, G. P.;
Tikhomirol, A.;
Tomaru, T.;
Whitehorn, N.;
Zahn, A.;
Zahn, O.
Submitted: 2016-08-09
POLARBEAR-2 (PB-2) is a cosmic microwave background (CMB) polarization
experiment that will be located in the Atacama highland in Chile at an altitude
of 5200 m. Its science goals are to measure the CMB polarization signals
originating from both primordial gravitational waves and weak lensing. PB-2 is
designed to measure the tensor to scalar ratio, r, with precision {\sigma}(r) <
0.01, and the sum of neutrino masses, {\Sigma}m{\nu}, with
{\sigma}({\Sigma}m{\nu}) < 90 meV. To achieve these goals, PB-2 will employ
7588 transition-edge sensor bolometers at 95 GHz and 150 GHz, which will be
operated at the base temperature of 250 mK. Science observations will begin in
2017.
[6]
oai:arXiv.org:1512.07299 [pdf] - 1359106
The POLARBEAR-2 and the Simons Array Experiment
Suzuki, A.;
Ade, P.;
Akiba, Y.;
Aleman, C.;
Arnold, K.;
Baccigalupi, C.;
Barch, B.;
Barron, D.;
Bender, A.;
Boettger, D.;
Borrill, J.;
Chapman, S.;
Chinone, Y.;
Cukierman, A.;
Dobbs, M.;
Ducout, A.;
Dunner, R.;
Elleflot, T.;
Errard, J.;
Fabbian, G.;
Feeney, S.;
Feng, C.;
Fujino, T.;
Fuller, G.;
Gilbert, A.;
Goeckner-Wald, N.;
Groh, J.;
De Haan, T.;
Hall, G.;
Halverson, N.;
Hamada, T.;
Hasegawa, M.;
Hattori, K.;
Hazumi, M.;
Hill, C.;
Holzapfel, W.;
Hori, Y.;
Howe, L.;
Inoue, Y.;
Irie, F.;
Jaehnig, G.;
Jaffe, A.;
Jeong, O.;
Katayama, N.;
Kaufman, J.;
Kazemzadeh, K.;
Keating, B.;
Kermish, Z.;
Keskitalo, R.;
Kisner, T.;
Kusaka, A.;
Jeune, M. Le;
Lee, A.;
Leon, D.;
Linder, E.;
Lowry, L.;
Matsuda, F.;
Matsumura, T.;
Miller, N.;
Mizukami, K.;
Montgomery, J.;
Navaroli, M.;
Nishino, H.;
Peloton, J.;
Poletti, D.;
Rebeiz, G.;
Raum, C.;
Reichardt, C.;
Richards, P.;
Ross, C.;
Rotermund, K.;
Segawa, Y.;
Sherwin, B.;
Shirley, I.;
Siritanasak, P.;
Stebor, N.;
Stompor, R.;
Suzuki, J.;
Tajima, O.;
Takada, S.;
Takakura, S.;
Takatori, S.;
Tikhomirov, A.;
Tomaru, T.;
Westbrook, B.;
Whitehorn, N.;
Yamashita, T.;
Zahn, A.;
Zahn, O.
Submitted: 2015-12-22
We present an overview of the design and status of the \Pb-2 and the Simons
Array experiments. \Pb-2 is a Cosmic Microwave Background polarimetry
experiment which aims to characterize the arc-minute angular scale B-mode
signal from weak gravitational lensing and search for the degree angular scale
B-mode signal from inflationary gravitational waves. The receiver has a 365~mm
diameter focal plane cooled to 270~milli-Kelvin. The focal plane is filled with
7,588 dichroic lenslet-antenna coupled polarization sensitive Transition Edge
Sensor (TES) bolometric pixels that are sensitive to 95~GHz and 150~GHz bands
simultaneously. The TES bolometers are read-out by SQUIDs with 40 channel
frequency domain multiplexing. Refractive optical elements are made with high
purity alumina to achieve high optical throughput. The receiver is designed to
achieve noise equivalent temperature of 5.8~$\mu$K$_{CMB}\sqrt{s}$ in each
frequency band. \Pb-2 will deploy in 2016 in the Atacama desert in Chile. The
Simons Array is a project to further increase sensitivity by deploying three
\Pb-2 type receivers. The Simons Array will cover 95~GHz, 150~GHz and 220~GHz
frequency bands for foreground control. The Simons Array will be able to
constrain tensor-to-scalar ratio and sum of neutrino masses to $\sigma(r) =
6\times 10^{-3}$ at $r = 0.1$ and $\sum m_\nu (\sigma =1)$ to 40 meV.
[7]
oai:arXiv.org:1410.7488 [pdf] - 894214
Development and characterization of the readout system for POLARBEAR-2
Barron, D.;
Ade, P. A. R.;
Akiba, Y.;
Aleman, C.;
Arnold, K.;
Atlas, M.;
Bender, A.;
Boettger, D.;
Borrill, J.;
Chapman, S.;
Chinone, Y.;
Cukierman, A.;
Dobbs, M.;
Elleflot, T.;
Errard, J.;
Fabbian, G.;
Feng, C.;
Gilbert, A.;
Goeckner-Wald, N.;
Halverson, N. W.;
Hasegawa, M.;
Hattori, K.;
Hazumi, M.;
Holzapfel, W. L.;
Hori, Y.;
Inoue, Y.;
Jaehnig, G. C.;
Jaffe, A. H.;
Katayama, N.;
Keating, B.;
Kermish, Z.;
Keskitalo, R.;
Kisner, T.;
Jeune, M. Le;
Lee, A. T.;
Leitch, E. M.;
Linder, E.;
Matsuda, F.;
Matsumura, T.;
Meng, X.;
Morii, H.;
Myers, M. J.;
Navaroli, M.;
Nishino, H.;
Okamura, T.;
Paar, H.;
Peloton, J.;
Poletti, D.;
Raum, C.;
Rebeiz, G.;
Reichardt, C. L.;
Richards, P. L.;
Ross, C.;
Rotermund, K.;
Schenck, D. E.;
Sherwin, B. D.;
Shirley, I.;
Sholl, M.;
Siritanasak, P.;
Smecher, G.;
Stebor, N.;
Steinbach, B.;
Stompor, R.;
Suzuki, A.;
Suzuki, J.;
Takada, S.;
Takakura, S.;
Tomaru, T.;
Wilson, B.;
Yadav, A.;
Yamaguchi, H.;
Zahn, O.
Submitted: 2014-10-27, last modified: 2014-11-06
POLARBEAR-2 is a next-generation receiver for precision measurements of the
polarization of the cosmic microwave background (Cosmic Microwave Background
(CMB)). Scheduled to deploy in early 2015, it will observe alongside the
existing POLARBEAR-1 receiver, on a new telescope in the Simons Array on Cerro
Toco in the Atacama desert of Chile. For increased sensitivity, it will feature
a larger area focal plane, with a total of 7,588 polarization sensitive
antenna-coupled Transition Edge Sensor (TES) bolometers, with a design
sensitivity of 4.1 uKrt(s). The focal plane will be cooled to 250 milliKelvin,
and the bolometers will be read-out with 40x frequency domain multiplexing,
with 36 optical bolometers on a single SQUID amplifier, along with 2 dark
bolometers and 2 calibration resistors. To increase the multiplexing factor
from 8x for POLARBEAR-1 to 40x for POLARBEAR-2 requires additional bandwidth
for SQUID readout and well-defined frequency channel spacing. Extending to
these higher frequencies requires new components and design for the LC filters
which define channel spacing. The LC filters are cold resonant circuits with an
inductor and capacitor in series with each bolometer, and stray inductance in
the wiring and equivalent series resistance from the capacitors can affect
bolometer operation. We present results from characterizing these new readout
components. Integration of the readout system is being done first on a small
scale, to ensure that the readout system does not affect bolometer sensitivity
or stability, and to validate the overall system before expansion into the full
receiver. We present the status of readout integration, and the initial results
and status of components for the full array.
[8]
oai:arXiv.org:1311.2847 [pdf] - 855791
Mission design of LiteBIRD
Matsumura, T.;
Akiba, Y.;
Borrill, J.;
Chinone, Y.;
Dobbs, M.;
Fuke, H.;
Ghribi, A.;
Hasegawa, M.;
Hattori, K.;
Hattori, M.;
Hazumi, M.;
Holzapfel, W.;
Inoue, Y.;
Ishidoshiro, K.;
Ishino, H.;
Ishitsuka, H.;
Karatsu, K.;
Katayama, N.;
Kawano, I.;
Kibayashi, A.;
Kibe, Y.;
Kimura, K.;
Kimura, N.;
Koga, K.;
Kozu, M.;
Komatsu, E.;
Lee, A.;
Matsuhara, H.;
Mima, S.;
Mitsuda, K.;
Mizukami, K.;
Morii, H.;
Morishima, T.;
Murayama, S.;
Nagai, M.;
Nagata, R.;
Nakamura, S.;
Naruse, M.;
Natsume, K.;
Nishibori, T.;
Nishino, H.;
Noda, A.;
Noguchi, T.;
Ogawa, H.;
Oguri, S.;
Ohta, I.;
Otani, C.;
Richards, P.;
Sakai, S.;
Sato, N.;
Sato, Y.;
Sekimoto, Y.;
Shimizu, A.;
Shinozaki, K.;
Sugita, H.;
Suzuki, T.;
Suzuki, A.;
Tajima, O.;
Takada, S.;
Takakura, S.;
Takei, Y.;
Tomaru, T.;
Uzawa, Y.;
Wada, T.;
Watanabe, H.;
Yamasaki, N.;
Yoshida, M.;
Yoshida, T.;
Yotsumoto, K.
Submitted: 2013-11-12
LiteBIRD is a next-generation satellite mission to measure the polarization
of the cosmic microwave background (CMB) radiation. On large angular scales the
B-mode polarization of the CMB carries the imprint of primordial gravitational
waves, and its precise measurement would provide a powerful probe of the epoch
of inflation. The goal of LiteBIRD is to achieve a measurement of the
characterizing tensor to scalar ratio $r$ to an uncertainty of $\delta
r=0.001$. In order to achieve this goal we will employ a kilo-pixel
superconducting detector array on a cryogenically cooled sub-Kelvin focal plane
with an optical system at a temperature of 4~K. We are currently considering
two detector array options; transition edge sensor (TES) bolometers and
microwave kinetic inductance detectors (MKID). In this paper we give an
overview of LiteBIRD and describe a TES-based polarimeter designed to achieve
the target sensitivity of 2~$\mu$K$\cdot$arcmin over the frequency range 50 to
320~GHz.