sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Takada, Atsushi

Normalized to: Takada, A.

24 article(s) in total. 207 co-authors, from 1 to 23 common article(s). Median position in authors list is 4,0.

[1]  oai:arXiv.org:1907.06658  [pdf] - 1917066
A Space-based All-sky MeV gamma-ray Survey with the Electron Tracking Compton Camera
Comments: 14 pages, 5 figures, 1 table, Astro 2020 APC white paper
Submitted: 2019-07-15
A sensitive survey of the MeV gamma-ray sky is needed to understand important astrophysical problems such as gamma-ray bursts in the early universe, progenitors of Type Ia supernovae, and the nature of dark matter. However, the study has not progressed remarkably since the limited survey by COMPTEL onboard CGRO in the 1990s. Tanimori et al. have developed a Compton camera that tracks the trajectory of each recoil electron in addition to the information obtained by the conventional Compton cameras, leading to superior imaging. This Electron Tracking Compton Camera (ETCC) facilitates accurate reconstruction of the incoming direction of each MeV photon from a wide sky at ~degree angular resolution and with minimized particle background using trajectory information. The latest ETCC model, SMILE-2+, made successful astronomical observations during a day balloon flight in 2018 April and detected diffuse continuum and 511 keV annihilation line emission from the Galactic Center region at a high significance in ~2.5 hours. We believe that MeV observations from space with upgraded ETCCs will dramatically improve our knowledge of the MeV universe. We advocate for a space-based all-sky survey mission with multiple ETCCs onboard and detail its expected benefits.
[2]  oai:arXiv.org:1805.07939  [pdf] - 1685970
Systematic Study of Nuclear Gamma-Ray Spectra of One Hundred Super Novae Expected by Future Nuclear Gamma-Ray Imaging Spectroscopic Observations
Comments: 14 pages, 13 figures, submitted to a journal
Submitted: 2018-05-21
Supernovae (SNe) are the most fascinating objects in astronomy and are intensely investigated. However, many mysteries such as nucleosynthesis and the origin of SNe Ia remain unsolved. Although the thermonuclear explosion of a single-degenerate white dwarf has been considered to be the origin of SNe Ia, a merger of two white dwarfs (double-degenerate scenario) has been frequently denoted to be more promising than a single-degenerate white dwarf. Recently the importance of observing the MeV gamma-ray band to conclusively determine the origin has been remarked. MeV gamma-rays are unique probes directly emitted from the exploding or merging region. It is evident that statistical analysis based on imaging spectroscopic observations of ~100 SNe Ia with MeV gamma-rays is necessary to obtain a definite answer. To achieve this, a telescope with a sensitivity that is 100 times that of COMPTEL is necessary. Proper imaging spectroscopy for the MeV gamma-ray band has been established by an electron-tracking Compton camera; hence, a concrete design of a MeV gamma-ray telescope has been proposed in our previous work. We have studied the details of the spectroscopic feature of SNe Ia based on the performance of a proposed telescope and found that statistical analysis can considerably suppress fluctuations of the individual properties of SNe and reveal their intrinsic differences in averaged light curves of SNe up to 60 Mpc. Our answer for the origin of SNe Ia extends to the case of single-degenerate scenario and double-degenerate coexistence scenario.
[3]  oai:arXiv.org:1709.06219  [pdf] - 1648626
Study of Negative-Ion TPC Using {\mu}-PIC for Directional Dark Matter Search
Comments:
Submitted: 2017-09-18
Negative-ion time projection chambers(TPCs) have been studied for low-rate and high-resolution applications such as dark matter search experiments. Recently, a full volume fiducialization in a self-triggering TPC was realized. This innovative technology demonstrated a significant reduction in the background with MWPC-TPCs. We studied negative-ion TPC using the {\mu}-PIC+GEM system and obtained sufficient gas gain with CS$_{2}$gas and SF$_{6}$ gas at low pressures. We expect an improvement in detector sensitivity and angular resolution with better electronics.
[4]  oai:arXiv.org:1703.07600  [pdf] - 1564143
Imaging Polarimeter for a Sub-MeV Gamma-Ray All-Sky Survey using an Electron-Tracking Compton Camera
Comments: 22 pages, 19 figures, 1 table, accepted for publication in ApJ
Submitted: 2017-03-22
X-ray and gamma-ray polarimetry is a promising tool to study the geometry and the magnetic configuration of various celestial objects, such as binary black holes or gamma-ray bursts (GRBs). However, statistically significant polarizations have been detected in few of the brightest objects. Even though future polarimeters using X-ray telescopes are expected to observe weak persistent sources, there are no effective approaches to survey transient and serendipitous sources with a wide field of view (FoV). Here we present an electron-tracking Compton camera (ETCC) as a highly-sensitive gamma-ray imaging polarimeter. The ETCC provides powerful background rejection and a high modulation factor over a FoV of up to 2$\pi$ sr thanks to its excellent imaging based on a well-defined point spread function. Importantly, we demonstrated for the first time the stability of the modulation factor under realistic conditions of off-axis incidence and huge backgrounds using the SPring-8 polarized X-ray beam. The measured modulation factor of the ETCC was 0.65 $\pm$ 0.01 at 150 keV for an off-axis incidence with an oblique angle of 30$^\circ$ and was not degraded compared to the 0.58 $\pm$ 0.02 at 130 keV for on-axis incidence. These measured results are consistent with the simulation results. Consequently, we found that the satellite-ETCC proposed in Tanimori et al. (2015) would provide all-sky surveys of weak persistent sources of 13 mCrab with 10% polarization for a 10$^{7}$ s exposure and over 20 GRBs down to a $6\times10^{-6}$ erg cm$^{-2}$ fluence and 10% polarization during a one-year observation.
[5]  oai:arXiv.org:1702.01484  [pdf] - 1535426
First On-Site True Gamma-Ray Imaging-Spectroscopy of Contamination near Fukushima Plant
Comments: 19 pages, 7 figures, 2 tables
Submitted: 2017-02-05
We have developed an Electron Tracking Compton Camera (ETCC), which provides a well-defined Point Spread Function (PSF) by reconstructing a direction of each gamma as a point and realizes simultaneous measurement of brightness and spectrum of MeV gamma-rays for the first time. Here, we present the results of our on-site pilot gamma-imaging-spectroscopy with ETCC at three contaminated locations in the vicinity of the Fukushima Daiichi Nuclear Power Plants in Japan in 2014. The obtained distribution of brightness (or emissivity) with remote-sensing observations is unambiguously converted into the dose distribution. We confirm that the dose distribution is consistent with the one taken by conventional mapping measurements with a dosimeter physically placed at each grid point. Furthermore, its imaging spectroscopy, boosted by Compton-edge-free spectra, reveals complex radioactive features in a quantitative manner around each individual target point in the background-dominated environment. Notably, we successfully identify a "micro hot spot" of residual caesium contamination even in an already decontaminated area. These results show that the ETCC performs exactly as the geometrical optics predicts, demonstrates its versatility in the field radiation measurement, and reveals potentials for application in many fields, including the nuclear industry, medical field, and astronomy.
[6]  oai:arXiv.org:1702.01483  [pdf] - 1535425
Establishment of Imaging Spectroscopy of Nuclear Gamma-Rays based on Geometrical Optics
Comments: 22 pages, 8 figures
Submitted: 2017-02-05
Since the discovery of nuclear gamma-rays, its imaging has been limited to pseudo imaging, such as Compton Camera (CC) and coded mask. Pseudo imaging does not keep physical information (intensity, or brightness in Optics) along a ray, and thus is capable of no more than qualitative imaging of bright objects. To attain quantitative imaging, cameras that realize geometrical optics is essential, which would be, for nuclear MeV gammas, only possible via complete reconstruction of the Compton process. Recently we have revealed that "Electron Tracking Compton Camera" (ETCC) provides a well-defined Point Spread Function (PSF). The information of an incoming gamma is kept along a ray with the PSF and that is equivalent to geometrical optics. Here we present an imaging-spectroscopic measurement with the ETCC. Our results highlight the intrinsic difficulty with CCs in performing accurate imaging, and show that the ETCC surmounts this problem. The imaging capability also helps the ETCC suppress the noise level dramatically by ~3 orders of magnitude without a shielding structure. Furthermore, full reconstruction of Compton process with the ETCC provides spectra free of Compton edges. These results mark the first proper imaging of nuclear gammas based on the genuine geometrical optics.
[7]  oai:arXiv.org:1610.06843  [pdf] - 1938191
Possibility of Systematic Study of Supernova Explosions by Nuclear Imaging Spectroscopy
Comments: 4 pages, 2 figures, Proceedings of the 14th International Symposium on Nuclei in the Cosmos (NIC-XIV)
Submitted: 2016-10-21
An all-sky monitor with nuclear imaging spectroscopy is a promising tool for the systematic study of supernova explosions. In particular, progenitor scenarios of type-Ia supernovae, which are not yet well understood, can be resolved using light curves in the nuclear gamma-ray band. Here we report an expected result of an all-sky monitor with imaging spectroscopy using electron-tracking Compton camera, which will enable us to observe nuclear gamma-ray lines from type-Ia supernovae.
[8]  oai:arXiv.org:1610.02396  [pdf] - 1516330
Readout technologies for directional WIMP Dark Matter detection
Comments: 58 pages, 26 figures, accepted by Physics Reports
Submitted: 2016-10-06
The measurement of the direction of WIMP-induced nuclear recoils is a compelling but technologically challenging strategy to provide an unambiguous signature of the detection of Galactic dark matter. Most directional detectors aim to reconstruct the dark-matter-induced nuclear recoil tracks, either in gas or solid targets. The main challenge with directional detection is the need for high spatial resolution over large volumes, which puts strong requirements on the readout technologies. In this paper we review the various detector readout technologies used by directional detectors. In particular, we summarize the challenges, advantages and drawbacks of each approach, and discuss future prospects for these technologies.
[9]  oai:arXiv.org:1508.00990  [pdf] - 1268655
New readout and data-acquisition system in an electron-tracking Compton camera for MeV gamma-ray astronomy (SMILE-II)
Comments: 11 pages, 24 figures
Submitted: 2015-08-05, last modified: 2015-08-29
For MeV gamma-ray astronomy, we have developed an electron-tracking Compton camera (ETCC) as a MeV gamma-ray telescope capable of rejecting the radiation background and attaining the high sensitivity of near 1 mCrab in space. Our ETCC comprises a gaseous time-projection chamber (TPC) with a micro pattern gas detector for tracking recoil electrons and a position-sensitive scintillation camera for detecting scattered gamma rays. After the success of a first balloon experiment in 2006 with a small ETCC (using a 10$\times$10$\times$15 cm$^3$ TPC) for measuring diffuse cosmic and atmospheric sub-MeV gamma rays (Sub-MeV gamma-ray Imaging Loaded-on-balloon Experiment I; SMILE-I), a (30 cm)$^{3}$ medium-sized ETCC was developed to measure MeV gamma-ray spectra from celestial sources, such as the Crab Nebula, with single-day balloon flights (SMILE-II). To achieve this goal, a 100-times-larger detection area compared with that of SMILE-I is required without changing the weight or power consumption of the detector system. In addition, the event rate is also expected to dramatically increase during observation. Here, we describe both the concept and the performance of the new data-acquisition system with this (30 cm)$^{3}$ ETCC to manage 100 times more data while satisfying the severe restrictions regarding the weight and power consumption imposed by a balloon-borne observation. In particular, to improve the detection efficiency of the fine tracks in the TPC from $\sim$10\% to $\sim$100\%, we introduce a new data-handling algorithm in the TPC. Therefore, for efficient management of such large amounts of data, we developed a data-acquisition system with parallel data flow.
[10]  oai:arXiv.org:1508.01287  [pdf] - 1259555
A performance study of an electron-tracking Compton camera with a compact system for environmental gamma-ray observation
Comments: 10 pages, 7 figures, proceeding of the 10th International Conference on Position Sensitive Detectors (PSD10)
Submitted: 2015-08-06
An electron-tracking Compton camera (ETCC) is a detector that can determine the arrival direction and energy of incident sub-MeV/MeV gamma-ray events on an event-by-event basis. It is a hybrid detector consisting of a gaseous time projection chamber (TPC), that is the Compton-scattering target and the tracker of recoil electrons, and a position-sensitive scintillation camera that absorbs of the scattered gamma rays, to measure gamma rays in the environment from contaminated soil. To measure of environmental gamma rays from soil contaminated with radioactive cesium (Cs), we developed a portable battery-powered ETCC system with a compact readout circuit and data-acquisition system for the SMILE-II experiment. We checked the gamma-ray imaging ability and ETCC performance in the laboratory by using several gamma-ray point sources. The performance test indicates that the field of view (FoV) of the detector is about 1$\;$sr and that the detection efficiency and angular resolution for 662$\;$keV gamma rays from the center of the FoV is $(9.31 \pm 0.95) \times 10^{^-5}$ and $5.9^{\circ} \pm 0.6^{\circ}$, respectively. Furthermore, the ETCC can detect 0.15$\;\mu\rm{Sv/h}$ from a $^{137}$Cs gamma-ray source with a significance of 5$\sigma$ in 13 min in the laboratory. In this paper, we report the specifications of the ETCC and the results of the performance tests. Furthermore, we discuss its potential use for environmental gamma-ray measurements.
[11]  oai:arXiv.org:1507.03850  [pdf] - 1267930
An Electron-Tracking Compton Telescope for a Survey of the Deep Universe by MeV gamma-rays
Comments: 19 pages, 12 figures, Accepted to the Astrophysical Journal
Submitted: 2015-07-14, last modified: 2015-08-04
Photon imaging for MeV gammas has serious difficulties due to huge backgrounds and unclearness in images, which are originated from incompleteness in determining the physical parameters of Compton scattering in detection, e.g., lack of the directional information of the recoil electrons. The recent major mission/instrument in the MeV band, Compton Gamma Ray Observatory/COMPTEL, which was Compton Camera (CC), detected mere $\sim30$ persistent sources. It is in stark contrast with $\sim$2000 sources in the GeV band. Here we report the performance of an Electron-Tracking Compton Camera (ETCC), and prove that it has a good potential to break through this stagnation in MeV gamma-ray astronomy. The ETCC provides all the parameters of Compton-scattering by measuring 3-D recoil electron tracks; then the Scatter Plane Deviation (SPD) lost in CCs is recovered. The energy loss rate (dE/dx), which CCs cannot measure, is also obtained, and is found to be indeed helpful to reduce the background under conditions similar to space. Accordingly the significance in gamma detection is improved severalfold. On the other hand, SPD is essential to determine the point-spread function (PSF) quantitatively. The SPD resolution is improved close to the theoretical limit for multiple scattering of recoil electrons. With such a well-determined PSF, we demonstrate for the first time that it is possible to provide reliable sensitivity in Compton imaging without utilizing an optimization algorithm. As such, this study highlights the fundamental weak-points of CCs. In contrast we demonstrate the possibility of ETCC reaching the sensitivity below $1\times10^{-12}$ erg cm$^{-2}$ s$^{-1}$ at 1 MeV.
[12]  oai:arXiv.org:1503.03152  [pdf] - 983537
Prospect for Future MeV Gamma-ray Active Galactic Nuclei Population Studies
Comments: 9 pages, 5 figures, accepted for publication in PASJ
Submitted: 2015-03-10, last modified: 2015-04-21
While the X-ray, GeV gamma-ray, and TeV gamma-ray skies have been extensively studied, the MeV gamma-ray sky is not well investigated after the Imaging Compton Telescope (COMPTEL) scanned the sky about two decades ago. In this paper, we investigate prospects for active galactic nuclei population studies with future MeV gamma-ray missions using recent spectral models and luminosity functions of Seyfert and flat spectrum radio quasars (FSRQs). Both of them are plausible candidates as the origins of the cosmic MeV gamma-ray background. If the cosmic MeV gamma-ray background radiation is dominated by non-thermal emission from Seyferts, the sensitivity of 10^-12 erg cm^-2 s^-1 is required to detect several hundred Seyferts in the entire sky. If FSRQs make up the cosmic MeV gamma-ray background, the sensitivity of ~4 x 10^-12 erg cm^-2 s^-1 is required to detect several hundred FSRQs following the recent FSRQ X-ray luminosity function. However, based on the latest FSRQ gamma-ray luminosity function, with which FSRQs can explain up to ~30% of the MeV background, we can expect several hundred FSRQs even with the sensitivity of 10^-11 erg cm^-2 s^-1 which is almost the same as the sensitivity goal of the next generation MeV telescopes.
[13]  oai:arXiv.org:1412.3918  [pdf] - 1223621
Performance of a new electron-tracking Compton camera under intense radiations from a water target irradiated with a proton beam
Comments: 10 pages, 8figures, http://www-cr.scphys.kyoto-u.ac.jp/research/MeV-gamma/wiki/wiki.cgi , PSD10
Submitted: 2014-12-12, last modified: 2015-01-22
We have developed an electron-tracking Compton camera (ETCC) for use in next-generation MeV gamma ray telescopes. An ETCC consists of a gaseous time projection chamber (TPC) and pixel scintillator arrays (PSAs). Since the TPC measures the three dimensional tracks of Compton-recoil electrons, the ETCC can completely reconstruct the incident gamma rays. Moreover, the ETCC demonstrates efficient background rejection power in Compton-kinematics tests, identifies particle from the energy deposit rate (dE/dX) registered in the TPC, and provides high quality imaging by completely reconstructing the Compton scattering process. We are planning the "Sub-MeV gamma ray Imaging Loaded-on-balloon Experiment" (SMILE) for our proposed all-sky survey satellite. Performance tests of a mid-sized 30 cm-cubic ETCC, constructed for observing the Crab nebula, are ongoing. However, observations at balloon altitudes or satellite orbits are obstructed by radiation background from the atmosphere and the detector itself. The background rejection power was checked using proton accelerator experiments conducted at the Research Center for Nuclear Physics, Osaka University. To create the intense radiation fields encountered in space, which comprise gamma rays, neutrons, protons, and other energetic entities, we irradiated a water target with a 140 MeV proton beam and placed a SMILE-II ETCC near the target. In this situation, the counting rate was five times than that expected at the balloon altitude. Nonetheless, the ETCC stably operated and identified particles sufficiently to obtain a clear gamma ray image of the checking source. Here, we report the performance of our detector and demonstrate its effective background rejection based in electron tracking experiments.
[14]  oai:arXiv.org:1312.0438  [pdf] - 829396
Development of a 30 cm-cube Electron-Tracking Compton Camera for the SMILE-II Experiment
Comments: 9 pages, 7 figures, Proceedings of the 15th International Workshop on Radiation Imaging Detectors (iWoRiD 2013)
Submitted: 2013-12-02, last modified: 2014-02-07
To explore the sub-MeV/MeV gamma-ray window for astronomy, we have developed the Electron-Tracking Compton Camera (ETCC), and carried out the first performance test at room condition using several gamma-ray sources in the sub-MeV energy band. Using a simple track analysis for a quick first test of the performance, the gamma-ray imaging capability was demonstrated by clear images and 5.3 degrees of angular resolution measure (ARM) measured at 662 keV. As the greatest impact of this work, a gamma-ray detection efficiency on the order of $10^{-4}$ was achieved at the sub-MeV gamma-ray band, which is one order of magnitude higher than our previous experiment. This angular resolution and detection efficiency enables us to detect the Crab Nebula at the 5 sigma level with several hours observation at balloon altitude in middle latitude. Furthermore, good consistency of efficiencies between this performance test and simulation including only physical processes has a large importance; it means we achieve nearly 100% detection of Compton recoil electrons. Thus, our estimation of enhancements by upgrades of the detector is more dependable. We are planning to confirm the imaging capability of the ETCC by observation of celestial objects in the SMILE-II (Sub-MeV gamma ray Imaging Loaded-on-balloon Experiment II). The SMILE-II and following SMILE-III project will be an important key of sub-MeV/MeV gamma-ray astronomy.
[15]  oai:arXiv.org:1109.3099  [pdf] - 1084087
NEWAGE
Comments: Proceedings of the 3rd International conference on Directional Detection of Dark Matter (CYGNUS 2011), Aussois, France, 8-10 June 2011
Submitted: 2011-09-14, last modified: 2011-09-15
NEWAGE is a direction-sensitive dark matter search experiment with a gaseous time-projection chamber. We improved the direction-sensitive dark matter limits by our underground measurement. After the first underground run, we replaced the detector components with radio-pure materials. We also studied the possibilities of head-tail recognition of nuclear tracks in the surface laboratory. For the future large volume detector, we are developing a pixel ASIC named QPIX. In this paper, these recent R&D activities are described.
[16]  oai:arXiv.org:1103.3436  [pdf] - 966507
Observation of Diffuse Cosmic and Atmospheric Gamma Rays at Balloon Altitudes with an Electron-tracking Compton Camera
Comments: The Astrophysical Journal accepted
Submitted: 2011-03-17, last modified: 2011-03-23
We observed diffuse cosmic and atmospheric gamma rays at balloon altitudes with the Sub-MeV gamma-ray Imaging Loaded-on-balloon Experiment I (SMILE-I) as the first step toward a future all-sky survey with a high sensitivity. SMILE-I employed an electron-tracking Compton camera comprised of a gaseous electron tracker as a Compton-scattering target and a scintillation camera as an absorber. The balloon carrying the SMILE-I detector was launched from the Sanriku Balloon Center of the Institute of Space and Astronomical Science/Japan Space Exploration Agency on September 1, 2006, and the flight lasted for 6.8 hr, including level flight for 4.1 hr at an altitude of 32-35 km. During the level flight, we successfully detected 420 downward gamma rays between 100 keV and 1 MeV at zenith angles below 60 degrees. To obtain the flux of diffuse cosmic gamma rays, we first simulated their scattering in the atmosphere using Geant4, and for gamma rays detected at an atmospheric depth of 7.0 g cm-2, we found that 50% and 21% of the gamma rays at energies of 150 keV and 1 MeV, respectively, were scattered in the atmosphere prior to reaching the detector. Moreover, by using Geant4 simulations and the QinetiQ atmospheric radiation model, we estimated that the detected events consisted of diffuse cosmic and atmospheric gamma rays (79%), secondary photons produced in the instrument through the interaction between cosmic rays and materials surrounding the detector (19%), and other particles (2%). The obtained growth curve was comparable to Ling's model, and the fluxes of diffuse cosmic and atmospheric gamma rays were consistent with the results of previous experiments. The expected detection sensitivity of a future SMILE experiment measuring gamma rays between 150 keV and 20 MeV was estimated from our SMILE-I results and was found to be ten times better than that of other experiments at around 1 MeV.
[17]  oai:arXiv.org:1002.1794  [pdf] - 1025066
First underground results with NEWAGE-0.3a direction-sensitive dark matter detector
Comments: 21 pages, 8 figures, to appear in Physics Letters B
Submitted: 2010-02-09
A direction-sensitive dark matter search experiment at Kamioka underground laboratory with the NEWAGE-0.3a detector was performed. The NEWAGE- 0.3a detector is a gaseous micro-time-projection chamber filled with CF4 gas at 152 Torr. The fiducial volume and target mass are 20*25*31 cm3 and 0.0115 kg, respectively. With an exposure of 0.524 kgdays, improved spin-dependent weakly interacting massive particle (WIMP)-proton cross section limits by a direction-sensitive method were achieved including a new record of 5400 pb for 150 GeV/c2 WIMPs. We studied the remaining background and found that ambient gamma-rays contributed about one-fifth of the remaining background and radioactive contaminants inside the gas chamber contributed the rest.
[18]  oai:arXiv.org:0911.0323  [pdf] - 902277
The case for a directional dark matter detector and the status of current experimental efforts
Comments: 48 pages, 37 figures, whitepaper on direct dark matter detection with directional sensitivity
Submitted: 2009-11-01
We present the case for a dark matter detector with directional sensitivity. This document was developed at the 2009 CYGNUS workshop on directional dark matter detection, and contains contributions from theorists and experimental groups in the field. We describe the need for a dark matter detector with directional sensitivity; each directional dark matter experiment presents their project's status; and we close with a feasibility study for scaling up to a one ton directional detector, which would cost around $150M.
[19]  oai:arXiv.org:0708.2579  [pdf] - 4090
Direction-sensitive dark matter search results in a surface laboratory
Comments: 9 figures, accepted for publication in Phys. Lett. B
Submitted: 2007-08-19
We developed a three-dimensional gaseous tracking device and performed a direction-sensitive dark matter search in a surface laboratory. By using 150 Torr carbon-tetrafluoride (CF_4 gas), we obtained a sky map drawn with the recoil directions of the carbon and fluorine nuclei, and set the first limit on the spin-dependent WIMP (Weakly Interacting Massive Particles)-proton cross section by a direction-sensitive method. Thus, we showed that a WIMP-search experiment with a gaseous tracking device can actually set limits. Furthermore, we demonstrated that this method will potentially play a certain role in revealing the nature of dark matter when a low-background large-volume detector is developed.
[20]  oai:arXiv.org:astro-ph/0601568  [pdf] - 79426
Development of Gaseous Tracking Devices for the Search of WIMPs
Comments: 8 pages, 4 figures, Proceedings of the 7th international workshop on position sensitive detectors(PSD7), submitted to NIM A
Submitted: 2006-01-25, last modified: 2006-02-14
The Time Projection Chamber (TPC) has been recognized as a potentially powerful detector for the search of WIMPs by measuring the directions of nuclear recoils, in which the most convincing signature of WIMPs, caused by the Earth's motion around the Galaxy, appears. We report on the first results of a performance study of the neutron exposure of our prototype micro-TPC with Ar-C$_2$H$_6$ (90:10) and CF$_4$ gas of 150 Torr.
[21]  oai:arXiv.org:astro-ph/0412047  [pdf] - 69451
Development of an advanced Compton camera with gaseous TPC and scintillator
Comments: 4 pages, 5 figures. Proceedings of the 6th International Workshop On Radiation Imaging Detectors
Submitted: 2004-12-02
A prototype of the MeV gamma-ray imaging camera based on the full reconstruction of the Compton process has been developed. This camera consists of a micro-TPC that is a gaseous Time Projection Chamber (TPC) and scintillation cameras. With the information of the recoil electrons and the scattered gamma-rays, this camera detects the energy and incident direction of each incident gamma-ray. We developed a prototype of the MeV gamma-ray camera with a micro-TPC and a NaI(Tl) scintillator, and succeeded in reconstructing the gamma-rays from 0.3 MeV to 1.3 MeV. Measured angular resolutions of ARM (Angular Resolution Measure) and SPD (Scatter Plane Deviation) for 356 keV gamma-rays were $18^\circ$ and $35^\circ$, respectively.
[22]  oai:arXiv.org:astro-ph/0403518  [pdf] - 63709
MeV Gamma-Ray Imaging Detector with micro-TPC
Comments: 7 pages, 6 figures Proceedings of the "Astronomy With Radioactives IV and Filling The Sensitivity Gap In MEV Astronomy", May 26-30, 2003 Seeon, Bavaria, Germany
Submitted: 2004-03-22
We propose a new imaging gamma-ray detector in the MeV region. By measuring the directions and energies of not only a scattered gamma ray but also a recoil electron, the direction of an incident gamma ray would be essentially reconstructed event by event. Furthermore, one of two measured (zenith and azimuth) angles of a recoil electron gives us an additional redundancy which enables us to reject the background events by kinematic constraints. In order to measure the track of a recoil electron, the micro Time Projection Chamber($\mu$-TPC) has been developed, which can measure the successive positions of the track of charged particles in a few hundred micron meter pitch. The $\mu$-TPC consists of the new type of a gas proportional chamber: micro PIxel gas Chamber ($\mu$-PIC) which is one of wireless gas chambers and expected to be robust and stable. Using this $\mu$-TPC and the Anger camera for the detection of a scattered gamma ray, we have obtained the first gamma-ray image by the full reconstruction of the direction of gamma rays event by event.
[23]  oai:arXiv.org:astro-ph/0310638  [pdf] - 880671
Detecting the WIMP-wind via spin-dependent interactions
Comments: 14 pages, 5 figures, submitted for Physics Letters B
Submitted: 2003-10-22
Revealing the nature of dark matter is one of the most interesting tasks in astrophysics. Measuring the distribution of recoil angles is said to be one of the most reliable methods to detect a positive signature of dark matter. We focused on measurements via spin-dependent interactions, and studied the feasibility with carbon tetrafluoride($\rm CF_4$) gas, while taking into account the performance of an existing three-dimensional tracking detector. We consequently found that it is highly possible to detect a positive signature of dark matter via spin-dependent interactions.
[24]  oai:arXiv.org:hep-ex/0301012  [pdf] - 113348
Performance of the TPC with Micro Pixel Chamber Readout: micro-TPC
Comments: 6 pages 16 figures, submitted for IEEE/TNS 2002
Submitted: 2003-01-10, last modified: 2003-04-02
Micro-TPC, a time projection chamber(TPC) with micro pixel chamber($\mu$-PIC) readout was developed for the detection of the three-dimensional fine(sub-m illimeter) tracks of charged particles. We developed a two-dimensional position sensitive gaseous detector, or the $\mu$-PIC, with the detection area of 10$\times$10 cm${}^{2}$ and 65536 anode electrodes of 400 $\mu$m pitch. We achieved the gas gain of over 10000 without any other multipliers. With the pipe-line readout system specially developed for the $\mu$-PIC, we detected X-rays at the rate as high as 7.7 Mcps. We attached a drift cage with an 8 cm drift length to the $\mu$-PIC and developed a micro-TPC. We measured the basic performances of the micro-TPC and took three-dimensional tracks of electrons. We also developed a prototype of the MeV gamma-ray imaging detector which is a hybrid of the micro-TPC and NaI(Tl) scintillators and confirmed its concept by reconstructing the obtained data.