Normalized to: Szypryt, P.
[1]
oai:arXiv.org:1907.03078 [pdf] - 1922487
Wide-band Parametric Amplifier Readout and Resolution of Optical
Microwave Kinetic Inductance Detectors
Zobrist, Nicholas;
Eom, Byeong Ho;
Day, Peter;
Mazin, Benjamin A.;
Meeker, Seth R.;
Bumble, Bruce;
LeDuc, Henry G.;
Coiffard, Gérgoire;
Szypryt, Paul;
Fruitwala, Neelay;
Lipartito, Isabel;
Bockstiegel, Clint
Submitted: 2019-07-06
The energy resolution of a single photon counting Microwave Kinetic
Inductance Detector (MKID) can be degraded by noise coming from the primary low
temperature amplifier in the detector's readout system. Until recently, quantum
limited amplifiers have been incompatible with these detectors due to dynamic
range, power, and bandwidth constraints. However, we show that a kinetic
inductance based traveling wave parametric amplifier can be used for this
application and reaches the quantum limit. The total system noise for this
readout scheme was equal to ~2.1 in units of quanta. For incident photons in
the 800 to 1300 nm range, the amplifier increased the average resolving power
of the detector from ~6.7 to 9.3 at which point the resolution becomes limited
by noise on the pulse height of the signal. Noise measurements suggest that a
resolving power of up to 25 is possible if redesigned detectors can remove this
additional noise source.
[2]
oai:arXiv.org:1803.10420 [pdf] - 1666883
DARKNESS: A Microwave Kinetic Inductance Detector Integral Field
Spectrograph for High-Contrast Astronomy
Meeker, Seth R.;
Mazin, Benjamin A.;
Walter, Alex B.;
Strader, Paschal;
Fruitwala, Neelay;
Bockstiegel, Clint;
Szypryt, Paul;
Ulbricht, Gerhard;
Coiffard, Gregoire;
Bumble, Bruce;
Cancelo, Gustavo;
Zmuda, Ted;
Treptow, Ken;
Wilcer, Neal;
Collura, Giulia;
Dodkins, Rupert;
Lipartito, Isabel;
Zobrist, Nicholas;
Bottom, Michael;
Shelton, J. Chris;
Mawet, Dimitri;
van Eyken, Julian C.;
Vasisht, Gautam;
Serabyn, Eugene
Submitted: 2018-03-28, last modified: 2018-04-16
We present DARKNESS (the DARK-speckle Near-infrared Energy-resolving
Superconducting Spectrophotometer), the first of several planned integral field
spectrographs to use optical/near-infrared Microwave Kinetic Inductance
Detectors (MKIDs) for high-contrast imaging. The photon counting and
simultaneous low-resolution spectroscopy provided by MKIDs will enable
real-time speckle control techniques and post-processing speckle suppression at
framerates capable of resolving the atmospheric speckles that currently limit
high-contrast imaging from the ground. DARKNESS is now operational behind the
PALM-3000 extreme adaptive optics system and the Stellar Double Coronagraph at
Palomar Observatory. Here we describe the motivation, design, and
characterization of the instrument, early on-sky results, and future prospects.
[3]
oai:arXiv.org:1710.07318 [pdf] - 1590047
Large-format platinum silicide microwave kinetic inductance detectors
for optical to near-IR astronomy
Szypryt, P.;
Meeker, S. R.;
Coiffard, G.;
Fruitwala, N.;
Bumble, B.;
Ulbricht, G.;
Walter, A. B.;
Daal, M.;
Bockstiegel, C.;
Collura, G.;
Zobrist, N.;
Lipartito, I.;
Mazin, B. A.
Submitted: 2017-10-19
We have fabricated and characterized 10,000 and 20,440 pixel Microwave
Kinetic Inductance Detector (MKID) arrays for the Dark-speckle Near-IR
Energy-resolved Superconducting Spectrophotometer (DARKNESS) and the MKID
Exoplanet Camera (MEC). These instruments are designed to sit behind adaptive
optics systems with the goal of directly imaging exoplanets in a 800-1400 nm
band. Previous large optical and near-IR MKID arrays were fabricated using
substoichiometric titanium nitride (TiN) on a silicon substrate. These arrays,
however, suffered from severe non-uniformities in the TiN critical temperature,
causing resonances to shift away from their designed values and lowering usable
detector yield. We have begun fabricating DARKNESS and MEC arrays using
platinum silicide (PtSi) on sapphire instead of TiN. Not only do these arrays
have much higher uniformity than the TiN arrays, resulting in higher pixel
yields, they have demonstrated better spectral resolution than TiN MKIDs of
similar design. PtSi MKIDs also do not display the hot pixel effects seen when
illuminating TiN on silicon MKIDs with photons with wavelengths shorter than 1
um.
[4]
oai:arXiv.org:1610.00725 [pdf] - 1496313
High Quality Factor Platinum Silicide Microwave Kinetic Inductance
Detectors
Submitted: 2016-10-03
We report on the development of Microwave Kinetic Inductance Detectors
(MKIDs) using platinum silicide as the sensor material. MKIDs are an emerging
superconducting detector technology, capable of measuring the arrival times of
single photons to better than two microseconds and their energies to around ten
percent. Previously, MKIDs have been fabricated using either sub-stoichiometric
titanium nitride or aluminum, but TiN suffers from spatial inhomogeneities in
the superconducting critical temperature and Al has a low kinetic inductance
fraction, causing low detector sensitivity. To address these issues, we have
instead fabricated PtSi microresonators with superconducting critical
temperatures of 944$\pm$12~mK and high internal quality factors ($Q_i \gtrsim
10^6$). These devices show typical quasiparticle lifetimes of $\tau_{qp}
\approx 30$--$40~\mu$s and spectral resolution, $R = \lambda / \Delta \lambda$,
of 8 at 406.6~nm. We compare PtSi MKIDs to those fabricated with TiN and detail
the substantial advantages that PtSi MKIDs have to offer.
[5]
oai:arXiv.org:1603.05270 [pdf] - 1385546
Search for Optical Pulsations in PSR J0337+1715
Strader, M. J.;
Archibald, A. M.;
Meeker, S. R.;
Szypryt, P.;
Walter, A. B.;
van Eyken, J. C.;
Ulbricht, G.;
Stoughton, C.;
Bumble, B.;
Kaplan, D. L.;
Mazin, B. A.
Submitted: 2016-03-16
We report on a search for optical pulsations from PSR J0337+1715 at its
observed radio pulse period. PSR J0337+1715 is a millisecond pulsar (2.7 ms
spin period) in a triple hierarchical system with two white dwarfs, and has a
known optical counterpart with g-band magnitude 18. The observations were done
with the Array Camera for Optical to Near-IR Spectrophotometry (ARCONS) at the
200" Hale telescope at Palomar Observatory. No significant pulsations were
found in the range 4000-11000 angstroms, and we can limit pulsed emission in
g-band to be fainter than 25 mag.
[6]
oai:arXiv.org:1507.05631 [pdf] - 1259174
The ARCONS Pipeline: Data Reduction for MKID Arrays
van Eyken, J. C.;
Strader, M. J.;
Walter, A. B.;
Meeker, S. R.;
Szypryt, P.;
Stoughton, C.;
O'Brien, K.;
Marsden, D.;
Rice, N. K.;
Lin, Y.;
Mazin, B. A.
Submitted: 2015-07-20
The Array Camera for Optical to Near-IR Spectrophotometry, or ARCONS, is a
camera based on Microwave Kinetic Inductance Detectors (MKIDs), a new
technology that has the potential for broad application in astronomy. Using an
array of MKIDs, the instrument is able to produce time-resolved imaging and
low-resolution spectroscopy constructed from detections of individual photons.
The arrival time and energy of each photon are recorded in a manner similar to
X-ray calorimetry, but at higher photon fluxes. The technique works over a very
large wavelength range, is free from fundamental read noise and dark-current
limitations, and provides microsecond-level timing resolution. Since the
instrument reads out all pixels continuously while exposing, there is no loss
of active exposure time to readout. The technology requires a different
approach to data reduction compared to conventional CCDs. We outline here the
prototype data reduction pipeline developed for ARCONS, though many of the
principles are also more broadly applicable to energy-resolved photon counting
arrays (e.g., transition edge sensors, superconducting tunnel junctions). We
describe the pipeline's current status, and the algorithms and techniques
employed in taking data from the arrival of photons at the MKID array to the
production of images, spectra, and time-resolved light curves.
[7]
oai:arXiv.org:1506.07537 [pdf] - 1237882
Highly Multiplexible Thermal Kinetic Inductance Detectors for X-Ray
Imaging Spectroscopy
Submitted: 2015-06-24
For X-ray imaging spectroscopy, high spatial resolution over a large field of
view is often as important as high energy resolution, but current X-ray
detectors do not provide both in the same device. Thermal Kinetic Inductance
Detectors (TKIDs) are being developed as they offer a feasible way to combine
the energy resolution of transition edge sensors with pixel counts approaching
CCDs and thus promise significant improvements for many X-ray spectroscopy
applications. TKIDs are a variation of Microwave Kinetic Inductance Detectors
(MKIDs) and share their multiplexibility: working MKID arrays with 2024 pixels
have recently been demonstrated and much bigger arrays are under development.
In this work, we present our first working TKID prototypes which are able to
achieve an energy resolution of 75 eV at 5.9 keV, even though their general
design still has to be optimized. We further describe TKID fabrication,
characterization, multiplexing and working principle and demonstrate the
necessity of a data fitting algorithm in order to extract photon energies. With
further design optimizations we expect to be able to improve our TKID energy
resolution to less than 10 eV at 5.9 keV.
[8]
oai:arXiv.org:1506.03458 [pdf] - 1161888
Science with KRAKENS
Mazin, Benjamin A.;
Becker, George;
France, Kevin;
Fraser, Wesley;
Howell, D. Andrew;
Jones, Tucker;
Meeker, Seth;
O'Brien, Kieran;
Prochaska, Jason X.;
Siana, Brian;
Strader, Matthew;
Szypryt, Paul;
Tendulkar, Shriharsh P.;
Treu, Tommaso;
Vasisht, Gautam
Submitted: 2015-06-10
The Keck science community is entering an era of unprecedented change.
Powerful new instrument like ZTF, JWST, LSST, and the ELTs will catalyze this
change, and we must be ready to take full advantage to maintain our position of
scientific leadership. The best way to do this is to continue the UC and
Caltech tradition of technical excellence in instrumentation. In this
whitepaper we describe a new instrument called KRAKENS to help meet these
challenges. KRAKENS uses a unique detector technology (MKIDs) to enable
groundbreaking science across a wide range of astrophysical research topics.
This document will lay out the detailed expected science return of KRAKENS.
[9]
oai:arXiv.org:1309.3270 [pdf] - 785198
Excess Optical Enhancement Observed with ARCONS for Early Crab Giant
Pulses
Strader, M. J.;
Johnson, M. D.;
Mazin, B. A.;
Jaeger, G. V. Spiro;
Gwinn, C. R.;
Meeker, S. R.;
Szypryt, P.;
van Eyken, J. C.;
Marsden, D.;
O'Brien, K.;
Walter, A. B.;
Ulbricht, G.;
Stoughton, C.;
Bumble, B.
Submitted: 2013-09-12, last modified: 2013-11-08
We observe an extraordinary link in the Crab pulsar between the enhancement
of an optical pulse and the timing of the corresponding giant radio pulse. At
optical through infrared wavelengths, our observations use the high time
resolution of ARCONS, a unique superconducting energy-resolving photon-counting
array at the Palomar 200-inch telescope. At radio wavelengths, we observe with
the Robert C. Byrd Green Bank Telescope and the GUPPI backend. We see an
$11.3\pm2.5\%$ increase in peak optical flux for pulses that have an
accompanying giant radio pulse arriving near the peak of the optical main
pulse, in contrast to a $3.2\pm0.5\%$ increase when an accompanying giant radio
pulse arrives soon after the optical peak. We also observe that the peak of the
optical main pulse is $2.8\pm0.8\%$ enhanced when there is a giant radio pulse
accompanying the optical interpulse. We observe no statistically significant
spectral differences between optical pulses accompanied by and not accompanied
by giant radio pulses. Our results extend previous observations of
optical-radio correlation to the time and spectral domains. Our refined
temporal correlation suggests that optical and radio emission are indeed
causally linked, and the lack of spectral differences suggests that the same
mechanism is responsible for all optical emission.
[10]
oai:arXiv.org:1309.4087 [pdf] - 785202
Direct Detection of SDSS J0926+3624 Orbital Expansion with ARCONS
Szypryt, P.;
Duggan, G. E.;
Mazin, B. A.;
Meeker, S. R.;
Strader, M. J.;
van Eyken, J. C.;
Marsden, D.;
O'Brien, K.;
Walter, A. B.;
Ulbricht, G.;
Prince, T. A.;
Stoughton, C.;
Bumble, B.
Submitted: 2013-09-16
AM Canum Venaticorum (AM CVn) stars belong to a class of ultra-compact, short
period binaries with spectra dominated largely by helium. SDSS J0926+3624 is of
particular interest as it is the first observed eclipsing AM CVn system. We
observed SDSS J0926+3624 with the \textbf{Ar}ray \textbf{C}amera for
\textbf{O}ptical to \textbf{N}ear-IR \textbf{S}pectrophotometry (ARCONS) at the
Palomar 200" telescope. ARCONS uses a relatively new type of energy-resolved
photon counters called Microwave Kinetic Inductance Detectors (MKIDs). ARCONS,
sensitive to radiation from 350 to 1100 nm, has a time resolution of several
microseconds and can measure the energy of a photon to $\sim10%$. We present
the light curves for these observations and examine changes in orbital period
from prior observations. Using a quadratic ephemeris model, we measure a period
rate of change $\dot{P} = (3.07 \pm 0.56)\times 10^{-13}$. In addition, we use
the high timing resolution of ARCONS to examine the system's high frequency
variations and search for possible quasi-periodic oscillations (QPOs). Finally,
we use the instrument's spectral resolution to examine the light curves in
various wavelength bands. We do not find any high frequency QPOs or significant
spectral variability throughout an eclipse.
[11]
oai:arXiv.org:1306.4674 [pdf] - 1172164
ARCONS: A 2024 Pixel Optical through Near-IR Cryogenic Imaging
Spectrophotometer
Mazin, B. A.;
Meeker, S. R.;
Strader, M. J.;
Bumble, B.;
O'Brien, K.;
Szypryt, P.;
Marsden, D.;
van Eyken, J. C.;
Duggan, G. E.;
Ulbricht, G.;
Stoughton, C.;
Johnson, M.
Submitted: 2013-06-19
We present the design, construction, and commissioning results of ARCONS, the
Array Camera for Optical to Near-IR Spectrophotometry. ARCONS is the first
ground-based instrument in the optical through near-IR wavelength range based
on Microwave Kinetic Inductance Detectors (MKIDs). MKIDs are revolutionary
cryogenic detectors, capable of detecting single photons and measuring their
energy without filters or gratings, similar to an X-ray microcalorimeter. MKIDs
are nearly ideal, noiseless photon detectors, as they do not suffer from read
noise or dark current and have nearly perfect cosmic ray rejection. ARCONS is
an Integral Field Spectrograph (IFS) containing a lens-coupled 2024 pixel MKID
array yielding a 20"x20" field of view, and has been deployed on the Palomar
200" and Lick 120" telescopes for 24 nights of observing. We present initial
results showing that ARCONS and its MKID arrays are now a fully operational and
powerful tool for astronomical observations.