[1]  oai:arXiv.org:1608.08603  [pdf] - 1470924
VIS: the visible imager for Euclid
Comments: 16 pages, 15 figures, 1 table
Submitted: 2016-08-30
Euclid-VIS is the large format visible imager for the ESA Euclid space mission in their Cosmic Vision program, scheduled for launch in 2020. Together with the near infrared imaging within the NISP instrument, it forms the basis of the weak lensing measurements of Euclid. VIS will image in a single r+i+z band from 550-900 nm over a field of view of ~0.5 deg2. By combining 4 exposures with a total of 2260 sec, VIS will reach to deeper than mAB=24.5 (10sigma) for sources with extent ~0.3 arcsec. The image sampling is 0.1 arcsec. VIS will provide deep imaging with a tightly controlled and stable point spread function (PSF) over a wide survey area of 15000 deg2 to measure the cosmic shear from nearly 1.5 billion galaxies to high levels of accuracy, from which the cosmological parameters will be measured. In addition, VIS will also provide a legacy dataset with an unprecedented combination of spatial resolution, depth and area covering most of the extra-Galactic sky. Here we will present the results of the study carried out by the Euclid Consortium during the period up to the Critical Design Review.
[2]  oai:arXiv.org:1412.5382  [pdf] - 1223687
Measuring a Charge-Coupled Device Point Spread Function: Euclid Visible Instrument CCD273-84 PSF Performance
Comments: Accepted for publication in Experimental Astronomy. Comments are welcome
Submitted: 2014-12-17, last modified: 2015-01-15
In this paper we present the testing of a back-illuminated development Euclid Visible Instrument (VIS) Charge-Coupled Device (CCD) to measure the intrinsic CCD Point Spread Function (PSF) characteristics using a novel modelling technique. We model the optical spot projection system and the CCD273-84 PSF jointly. We fit a model using Bayesian posterior probability density function, sampling to all available data simultaneously. The generative model fitting is shown, using simulated data, to allow good parameter estimations even when these data are not well sampled. Using available spot data we characterise a CCD273-84 PSF as a function of wavelength and intensity. The CCD PSF kernel size was found to increase with increasing intensity and decreasing wavelength.