Synyavski, I. I.
Normalized to: Synyavski, I.
2 article(s) in total. 10 co-authors, from 1 to 2 common article(s). Median position in authors list is 5,5.
[1]
oai:arXiv.org:1007.4694 [pdf] - 268107
Total ozone columns and vertical ozone profiles above Kiev in 2005-2008
Submitted: 2010-07-27, last modified: 2010-11-23
The study of total ozone columns above Kiev and variations of ozone
concentrations in the troposphere at different altitudes above Kiev was carried
out using ground-based Fourier Transform InfraRed (FTIR) spectrometric
observations that are taken on a routine basis at the Main Astronomical
Observatory of the National Academy of Sciences of Ukraine (MAO NASU). This
study was performed within the framework of the international ESA-NIVR-KNMI
OMI-AO project no.2907 entitled OMI validation by ground-based remote sensing:
ozone columns and atmospheric profiles during the time frame 2005-2008. The
infrared FTIR spectral observations of direct solar radiation in the wavelength
range of 2-12 micron as transmitted through the Earth's atmosphere were
performed during the months of April-October of each year. The aim of the
project was the validation of total ozone columns and vertical ozone profiles
as obtained by the Ozone Monitoring Instrument (OMI)) onboard of the NASA
EOS-Aura scientific satellite platform. The modeling of the ozone spectral band
shape near 9.6 microns was performing with the MODTRAN code and a molecular
band model based on the HITRAN-2004 molecular database. The a-priori
information for the spectral modeling consisted of water vapor and temperature
profiles from the NASA EOS-Aqua-AIRS satellite instrument, stratospheric ozone
profiles from the NASA EOS-Aura-MLS satellite instrument, TEMIS-KNMI
climatological ozone profiles and surface ozone concentration measurements
performed at the specific times of infrared spectra observations. The
troposphere ozone variability was analyzed for two typical episodes: the spring
episode of enhanced total ozone columns and the summer episode of enhanced
surface ozone concentrations.
[2]
oai:arXiv.org:1003.1211 [pdf] - 207007
Tropospheric ozone columns and ozone profiles for Kiev in 2007
Shavrina, A. V.;
Pavlenko, Ya. V.;
Veles, A. A.;
Sheminova, V. A.;
Synyavski, I. I.;
Sosonkin, M. G.;
Romanyuk, Ya. O.;
Eremenko, N. A.;
Ivanov, Yu. S.;
Monsar, O. A.;
Kroon, M.
Submitted: 2010-03-05, last modified: 2010-03-08
We report on ground-based FTIR observations being performed within the
framework of the ESA-NIVR-KNMI project 2907 entitled "OMI validation by ground
based remote sensing: ozone columns and atmospheric profiles" for the purpose
of OMI data validation. FTIR observations were performed during the time frames
August-October 2005, June-October 2006 and March-October 2007, mostly under
cloud free and clear sky conditions and in some days from early morning to
sunset covering the full range of solar zenith angles possible. Ozone column
and ozone profile data were obtained for the year 2005 using spectral modeling
of the ozone spectral band profile near 9.6 microns with the MODTRAN3 band
model based on the HITRAN-96 molecular absorption database. The total ozone
column values retrieved from FTIR observations are biased low with respect to
OMI-DOAS data by 8-10 DU on average, where they have a relatively small
standard error of about 2%. FTIR observations for the year 2006 were simulated
by MODTRAN4 modeling. For the retrieval of ozone column estimates and
particularly ozone profiles from our FTIR observations, we used the following
data sources to as input files to construct the (a priori) information for the
model: satellite Aqua-AIRS water vapor and temperature profiles; Aura-MLS
stratospheric ozone profiles (version 1.5), TEMIS climatological ozone profiles
and the simultaneously performed surface ozone measurements. Ozone total
columns obtained from our FTIR observations for year 2006 with MODTRAN4
modeling are matching rather well with OMI-TOMS and OMI-DOAS data where
standard errors are 0.68% and 1.11%, respectively. AURA-MLS data which have
become available in 2007 allow us to retrieve tropospheric ozone profiles.