Normalized to: Swanson, H.
[1]
oai:arXiv.org:1009.5720 [pdf] - 723020
Laser Ranging to the Lost Lunokhod~1 Reflector
Submitted: 2010-09-28, last modified: 2010-11-04
In 1970, the Soviet Lunokhod 1 rover delivered a French-built laser reflector
to the Moon. Although a few range measurements were made within three months of
its landing, these measurements---and any that may have followed---are
unpublished and unavailable. The Lunokhod 1 reflector was, therefore,
effectively lost until March of 2010 when images from the Lunar Reconnaissance
Orbiter (LRO) provided a positive identification of the rover and determined
its coordinates with uncertainties of about 100 m. This allowed the Apache
Point Observatory Lunar Laser-ranging Operation (APOLLO) to quickly acquire a
laser signal. The reflector appears to be in excellent condition, delivering a
signal roughly four times stronger than its twin reflector on the Lunokhod 2
rover. The Lunokhod 1 reflector is especially valuable for science because it
is closer to the Moon's limb than any of the other reflectors and, unlike the
Lunokhod 2 reflector, we find that it is usable during the lunar day. We report
the selenographic position of the reflector to few-centimeter accuracy, comment
on the health of the reflector, and illustrate the value of this reflector for
achieving science goals.
[2]
oai:arXiv.org:1003.0713 [pdf] - 723018
Long-term degradation of optical devices on the moon
Murphy,, T. W.;
Adelberger, E. G.;
Battat, J. B. R.;
Hoyle, C. D.;
McMillan, R. J.;
Michelsen, E. L.;
Samad, R.;
Stubbs, C. W.;
Swanson, H. E.
Submitted: 2010-03-02
Forty years ago, Apollo astronauts placed the first of several retroreflector
arrays on the lunar surface. Their continued usefulness for laser-ranging might
suggest that the lunar environment does not damage optical devices. However,
new laser ranging data reveal that the efficiency of the three Apollo reflector
arrays is now diminished by a factor of ten at all lunar phases and by an
additional factor of ten when the lunar phase is near full moon. These deficits
did not exist in the earliest years of lunar ranging, indicating that the lunar
environment damages optical equipment on the timescale of decades. Dust or
abrasion on the front faces of the corner-cube prisms may be responsible,
reducing their reflectivity and degrading their thermal performance when
exposed to face-on sunlight at full moon. These mechanisms can be tested using
laboratory simulations and must be understood before designing equipment
destined for the moon.
[3]
oai:arXiv.org:0710.0890 [pdf] - 554023
APOLLO: the Apache Point Observatory Lunar Laser-ranging Operation:
Instrument Description and First Detections
Murphy,, T. W.;
Adelberger, E. G.;
Battat, J. B. R.;
Carey, L. N.;
Hoyle, C. D.;
LeBlanc, P.;
Michelsen, E. L.;
Nordtvedt, K.;
Orin, A. E.;
Strasburg, J. D.;
Stubbs, C. W.;
Swanson, H. E.;
Williams, E.
Submitted: 2007-10-03, last modified: 2007-11-07
A next-generation lunar laser ranging apparatus using the 3.5 m telescope at
the Apache Point Observatory in southern New Mexico has begun science
operation. APOLLO (the Apache Point Observatory Lunar Laser-ranging Operation)
has achieved one-millimeter range precision to the moon which should lead to
approximately one-order-of-magnitude improvements in the precision of several
tests of fundamental properties of gravity. We briefly motivate the scientific
goals, and then give a detailed discussion of the APOLLO instrumentation.
[4]
oai:arXiv.org:nucl-ex/0111014 [pdf] - 118435
7Be(p,gamma)8B astrophysical S-factor from precision cross section
measurements
Junghans, A. R.;
Mohrmann, E. C.;
Snover, K. A.;
Steiger, T. D.;
Adelberger, E. G.;
Casandjian, J. -M.;
Swanson, H. E.;
Buchmann, L.;
Park, S. H.;
Zyuzin, A.
Submitted: 2001-11-16
We measured the 7Be(p,gamma)8B cross section from E_cm = 186 to 1200 keV,
with a statistical-plus-systematic precision per point of better than +- 5%.
All important systematic errors were measured including 8B backscattering
losses. We obtain S_17(0) = 22.3 +- 0.7(expt) +- 0.5(theor) eV-b from our data
at E_cm <= 300 keV and the theory of Descouvemont and Baye.