Normalized to: Surace, C.
[1]
oai:arXiv.org:1706.01103 [pdf] - 1659511
Automated reliability assessment for spectroscopic redshift measurements
Jamal, S.;
Brun, V. Le;
Fèvre, O. Le;
Vibert, D.;
Schmitt, A.;
Surace, C.;
Copin, Y.;
Garilli, B.;
Moresco, M.;
Pozzetti, L.
Submitted: 2017-06-04, last modified: 2018-01-22
We present a new approach to automate the spectroscopic redshift reliability
assessment based on machine learning (ML) and characteristics of the redshift
probability density function (PDF).
We propose to rephrase the spectroscopic redshift estimation into a Bayesian
framework, in order to incorporate all sources of information and uncertainties
related to the redshift estimation process, and produce a redshift posterior
PDF that will be the starting-point for ML algorithms to provide an automated
assessment of a redshift reliability.
As a use case, public data from the VIMOS VLT Deep Survey is exploited to
present and test this new methodology. We first tried to reproduce the existing
reliability flags using supervised classification to describe different types
of redshift PDFs, but due to the subjective definition of these flags, soon
opted for a new homogeneous partitioning of the data into distinct clusters via
unsupervised classification. After assessing the accuracy of the new clusters
via resubstitution and test predictions, unlabelled data from preliminary mock
simulations for the Euclid space mission are projected into this mapping to
predict their redshift reliability labels.
[2]
oai:arXiv.org:1712.06948 [pdf] - 1605449
The SPHERE data center: a reference for high contrast imaging processing
Delorme, Ph.;
Meunier, N.;
Albert, D.;
Lagadec, E.;
Coroller, H. Le;
Galicher, R.;
Mouillet, D.;
Boccaletti, A.;
Mesa, D.;
Meunier, J. -C.;
Beuzit., J. -L.;
Lagrange, A. -M.;
Chauvin, G.;
Sapone, A.;
Langlois, M.;
Maire, A. -L.;
Montargès, M.;
Gratton, R.;
Vigan, A.;
Surace, C.;
Moreau, C;
Fenouillet, Th.
Submitted: 2017-12-19
The objective of the SPHERE Data Center is to optimize the scientific return
of SPHERE at the VLT, by providing optimized reduction procedures, services to
users and publicly available reduced data. This paper describes our motivation,
the implementation of the service (partners, infrastructure and developments),
services, description of the on-line data, and future developments. The SPHERE
Data Center is operational and has already provided reduced data with a good
reactivity to many observers. The first public reduced data have been made
available in 2017. The SPHERE Data Center is gathering a strong expertise on
SPHERE data and is in a very good position to propose new reduced data in the
future, as well as improved reduction procedures.
[3]
oai:arXiv.org:1608.01075 [pdf] - 1531175
Prime Focus Spectrograph (PFS) for the Subaru Telescope: Overview,
recent progress, and future perspectives
Tamura, Naoyuki;
Takato, Naruhisa;
Shimono, Atsushi;
Moritani, Yuki;
Yabe, Kiyoto;
Ishizuka, Yuki;
Ueda, Akitoshi;
Kamata, Yukiko;
Aghazarian, Hrand;
Arnouts, Stephane;
Barban, Gabriel;
Barkhouser, Robert H.;
Borges, Renato C.;
Braun, David F.;
Carr, Michael A.;
Chabaud, Pierre-Yves;
Chang, Yin-Chang;
Chen, Hsin-Yo;
Chiba, Masashi;
Chou, Richard C. Y.;
Chu, You-Hua;
Cohen, Judith G.;
de Almeida, Rodrigo P.;
de Oliveira, Antonio C.;
de Oliveira, Ligia S.;
Dekany, Richard G.;
Dohlen, Kjetil;
Santos, Jesulino B. dos;
Santos, Leandro H. dos;
Ellis, Richard S.;
Fabricius, Maximilian;
Ferrand, Didier;
Ferreira, Decio;
Golebiowski, Mirek;
Greene, Jenny E.;
Gross, Johannes;
Gunn, James E.;
Hammond, Randolph;
Harding, Albert;
Hart, Murdock;
Heckman, Timothy M.;
Hirata, Christopher M.;
Ho, Paul;
Hope, Stephen C.;
Hovland, Larry;
Hsu, Shu-Fu;
Hu, Yen-Shan;
Huang, Ping-Jie;
Jaquet, Marc;
Jing, Yipeng;
Karr, Jennifer;
Kimura, Masahiko;
King, Matthew E.;
Komatsu, Eiichiro;
Brun, Vincent Le;
Fevre, Olivier Le;
Fur, Arnaud Le;
Mignant, David Le;
Ling, Hung-Hsu;
Loomis, Craig P.;
Lupton, Robert H.;
Madec, Fabrice;
Mao, Peter;
Marrara, Lucas S.;
de Oliveira, Claudia Mendes;
Minowa, Yosuke;
Morantz, Chaz N.;
Murayama, Hitoshi;
Murray, Graham J.;
Ohyama, Youichi;
Orndorff, Joseph;
Pascal, Sandrine;
Pereira, Jefferson M.;
Reiley, Daniel J.;
Reinecke, Martin;
Ritter, Andreas;
Roberts, Mitsuko;
Schwochert, Mark A.;
Seiffert, Michael D.;
Smee, Stephen A.;
Sodre, Laerte;
Spergel, David N.;
Steinkraus, Aaron J.;
Strauss, Michael A.;
Surace, Christian;
Suto, Yasushi;
Suzuki, Nao;
Swinbank, John;
Tait, Philip J.;
Takada, Masahiro;
Tamura, Tomonori;
Tanaka, Yoko;
Tresse, Laurence;
Verducci, Orlando;
Vibert, Didier;
Vidal, Clement;
Wang, Shiang-Yu;
Wen, Chih-Yi;
Yan, Chi-Hung;
Yasuda, Naoki
Submitted: 2016-08-03
PFS (Prime Focus Spectrograph), a next generation facility instrument on the
8.2-meter Subaru Telescope, is a very wide-field, massively multiplexed,
optical and near-infrared spectrograph. Exploiting the Subaru prime focus, 2394
reconfigurable fibers will be distributed over the 1.3 deg field of view. The
spectrograph has been designed with 3 arms of blue, red, and near-infrared
cameras to simultaneously observe spectra from 380nm to 1260nm in one exposure
at a resolution of ~1.6-2.7A. An international collaboration is developing this
instrument under the initiative of Kavli IPMU. The project is now going into
the construction phase aiming at undertaking system integration in 2017-2018
and subsequently carrying out engineering operations in 2018-2019. This article
gives an overview of the instrument, current project status and future paths
forward.
[4]
oai:arXiv.org:1507.00725 [pdf] - 1241387
Prime Focus Spectrograph for the Subaru telescope: massively multiplexed
optical and near-infrared fiber spectrograph
Sugai, Hajime;
Tamura, Naoyuki;
Karoji, Hiroshi;
Shimono, Atsushi;
Takato, Naruhisa;
Kimura, Masahiko;
Ohyama, Youichi;
Ueda, Akitoshi;
Aghazarian, Hrand;
de Arruda, Marcio Vital;
Barkhouser, Robert H.;
Bennett, Charles L.;
Bickerton, Steve;
Bozier, Alexandre;
Braun, David F.;
Bui, Khanh;
Capocasale, Christopher M.;
Carr, Michael A.;
Castilho, Bruno;
Chang, Yin-Chang;
Chen, Hsin-Yo;
Chou, Richard C. Y.;
Dawson, Olivia R.;
Dekany, Richard G.;
Ek, Eric M.;
Ellis, Richard S.;
English, Robin J.;
Ferrand, Didier;
Ferreira, Décio;
Fisher, Charles D.;
Golebiowski, Mirek;
Gunn, James E.;
Hart, Murdock;
Heckman, Timothy M.;
Ho, Paul T. P.;
Hope, Stephen;
Hovland, Larry E.;
Hsu, Shu-Fu;
Hu, Yen-Shan;
Huang, Pin Jie;
Jaquet, Marc;
Karr, Jennifer E.;
Kempenaar, Jason G.;
King, Matthew E.;
Fèvre, Olivier Le;
Mignant, David Le;
Ling, Hung-Hsu;
Loomis, Craig;
Lupton, Robert H.;
Madec, Fabrice;
Mao, Peter;
Marrara, Lucas Souza;
Ménard, Brice;
Morantz, Chaz;
Murayama, Hitoshi;
Murray, Graham J.;
de Oliveira, Antonio Cesar;
de Oliveira, Claudia Mendes;
de Oliveira, Ligia Souza;
Orndorff, Joe D.;
Vilaça, Rodrigo de Paiva;
Partos, Eamon J.;
Pascal, Sandrine;
Pegot-Ogier, Thomas;
Reiley, Daniel J.;
Riddle, Reed;
Santos, Leandro;
Santos, Jesulino Bispo dos;
Schwochert, Mark A.;
Seiffert, Michael D.;
Smee, Stephen A.;
Smith, Roger M.;
Steinkraus, Ronald E.;
Sodré, Laerte;
Spergel, David N.;
Surace, Christian;
Tresse, Laurence;
Vidal, Clément;
Vives, Sebastien;
Wang, Shiang-Yu;
Wen, Chih-Yi;
Wu, Amy C.;
Wyse, Rosie;
Yan, Chi-Hung
Submitted: 2015-07-02
The Prime Focus Spectrograph (PFS) is an optical/near-infrared multifiber
spectrograph with 2394 science fibers distributed across a 1.3-deg diameter
field of view at the Subaru 8.2-m telescope. The wide wavelength coverage from
0.38 {\mu}m to 1.26 {\mu}m, with a resolving power of 3000, simultaneously
strengthens its ability to target three main survey programs: cosmology,
galactic archaeology and galaxy/AGN evolution. A medium resolution mode with a
resolving power of 5000 for 0.71 {\mu}m to 0.89 {\mu}m will also be available
by simply exchanging dispersers. We highlight some of the technological aspects
of the design. To transform the telescope focal ratio, a broad-band coated
microlens is glued to each fiber tip. A higher transmission fiber is selected
for the longest part of the cable system, optimizing overall throughput; a
fiber with low focal ratio degradation is selected for the fiber-positioner and
fiber-slit components, minimizing the effects of fiber movements and fiber
bending. Fiber positioning will be performed by a positioner consisting of two
stages of piezo-electric rotary motors. The positions of these motors are
measured by taking an image of artificially back-illuminated fibers with the
metrology camera located in the Cassegrain container; the fibers are placed in
the proper location by iteratively measuring and then adjusting the positions
of the motors. Target light reaches one of the four identical fast-Schmidt
spectrograph modules, each with three arms. The PFS project has passed several
project-wide design reviews and is now in the construction phase.
[5]
oai:arXiv.org:1408.2825 [pdf] - 1216260
Progress with the Prime Focus Spectrograph for the Subaru Telescope: a
massively multiplexed optical and near-infrared fiber spectrograph
Sugai, Hajime;
Tamura, Naoyuki;
Karoji, Hiroshi;
Shimono, Atsushi;
Takato, Naruhisa;
Kimura, Masahiko;
Ohyama, Youichi;
Ueda, Akitoshi;
Aghazarian, Hrand;
de Arruda, Marcio Vital;
Barkhouser, Robert H.;
Bennett, Charles L.;
Bickerton, Steve;
Bozier, Alexandre;
Braun, David F.;
Bui, Khanh;
Capocasale, Christopher M.;
Carr, Michael A.;
Castilho, Bruno;
Chang, Yin-Chang;
Chen, Hsin-Yo;
Chou, Richard C. Y.;
Dawson, Olivia R.;
Dekany, Richard G.;
Ek, Eric M.;
Ellis, Richard S.;
English, Robin J.;
Ferrand, Didier;
Ferreira, Décio;
Fisher, Charles D.;
Golebiowski, Mirek;
Gunn, James E.;
Hart, Murdock;
Heckman, Timothy M.;
Ho, Paul T. P.;
Hope, Stephen;
Hovland, Larry E.;
Hsuc, Shu-Fu;
Hu, Yen-Shan;
Huang, Pin Jie;
Jaquet, Marc;
Karr, Jennifer E.;
Kempenaar, Jason G.;
King, Matthew E.;
Fèvre, Olivier Le;
Mignant, David Le;
Ling, Hung-Hsu;
Loomis, Craig;
Lupton, Robert H.;
Madec, Fabrice;
Mao, Peter;
Marrara, Lucas Souza;
Ménard, Brice;
Morantz, Chaz;
Murayama, Hitoshi;
Murray, Graham J.;
de Oliveira, Antonio Cesar;
de Oliveira, Claudia Mendes;
de Oliveira, Ligia Souza;
Orndorff, Joe D.;
Vilaça, Rodrigo de Paiva;
Partos, Eamon J.;
Pascal, Sandrine;
Pegot-Ogier, Thomas;
Reiley, Daniel J.;
Riddle, Reed;
Santos, Leandro;
Santos, Jesulino Bispo dos;
Schwochert, Mark A.;
Seiffert, Michael D.;
Smee, Stephen A.;
Smith, Roger M.;
Steinkraus, Ronald E.;
Sodré, Laerte;
Spergel, David N.;
Surace, Christian;
Tresse, Laurence;
Vidal, Clément;
Vives, Sebastien;
Wang, Shiang-Yu;
Wen, Chih-Yi;
Wu, Amy C.;
Wyse, Rosie;
Yan, Chi-Hung
Submitted: 2014-08-12
The Prime Focus Spectrograph (PFS) is an optical/near-infrared multi-fiber
spectrograph with 2394 science fibers, which are distributed in 1.3 degree
diameter field of view at Subaru 8.2-meter telescope. The simultaneous wide
wavelength coverage from 0.38 um to 1.26 um, with the resolving power of 3000,
strengthens its ability to target three main survey programs: cosmology,
Galactic archaeology, and galaxy/AGN evolution. A medium resolution mode with
resolving power of 5000 for 0.71 um to 0.89 um also will be available by simply
exchanging dispersers. PFS takes the role for the spectroscopic part of the
Subaru Measurement of Images and Redshifts project, while Hyper Suprime-Cam
works on the imaging part. To transform the telescope plus WFC focal ratio, a
3-mm thick broad-band coated glass-molded microlens is glued to each fiber tip.
A higher transmission fiber is selected for the longest part of cable system,
while one with a better FRD performance is selected for the fiber-positioner
and fiber-slit components, given the more frequent fiber movements and tightly
curved structure. Each Fiber positioner consists of two stages of
piezo-electric rotary motors. Its engineering model has been produced and
tested. Fiber positioning will be performed iteratively by taking an image of
artificially back-illuminated fibers with the Metrology camera located in the
Cassegrain container. The camera is carefully designed so that fiber position
measurements are unaffected by small amounts of high special-frequency
inaccuracies in WFC lens surface shapes. Target light carried through the fiber
system reaches one of four identical fast-Schmidt spectrograph modules, each
with three arms. Prototype VPH gratings have been optically tested. CCD
production is complete, with standard fully-depleted CCDs for red arms and
more-challenging thinner fully-depleted CCDs with blue-optimized coating for
blue arms.
[6]
oai:arXiv.org:1210.2719 [pdf] - 574579
Prime Focus Spectrograph - Subaru's future -
Sugai, Hajime;
Karoji, Hiroshi;
Takato, Naruhisa;
Tamura, Naoyuki;
Shimono, Atsushi;
Ohyama, Youichi;
Ueda, Akitoshi;
Ling, Hung-Hsu;
de Arruda, Marcio Vital;
Barkhouser, Robert H.;
Bennett, Charles L.;
Bickerton, Steve;
Braun, David F.;
Bruno, Robin J.;
Carr, Michael A.;
Oliveira, João Batista de Carvalho;
Chang, Yin-Chang;
Chen, Hsin-Yo;
Dekany, Richard G.;
Dominici, Tania Pereira;
Ellis, Richard S.;
Fisher, Charles D.;
Gunn, James E.;
Heckman, Timothy M.;
Ho, Paul T. P.;
Hu, Yen-Shan;
Jaquet, Marc;
Karr, Jennifer;
Kimura, Masahiko;
Fèvre, Olivier Le;
Mignant, David Le;
Loomis, Craig;
Lupton, Robert H.;
Madec, Fabrice;
Marrara, Lucas Souza;
Martin, Laurent;
Murayama, Hitoshi;
de Oliveira, Antonio Cesar;
de Oliveira, Claudia Mendes;
de Oliveira, Ligia Souza;
Orndorff, Joe D.;
Vilaça, Rodrigo de Paiva;
Macanhan, Vanessa Bawden de Paula;
Prieto, Eric;
Santos, Jesulino Bispo dos;
Seiffert, Michael D.;
Smee, Stephen A.;
Smith, Roger M.;
Sodré, Laerte;
Spergel, David N.;
Surace, Christian;
Vives, Sebastien;
Wang, Shiang-Yu;
Yan, Chi-Hung
Submitted: 2012-10-09
The Prime Focus Spectrograph (PFS) of the Subaru Measurement of Images and
Redshifts (SuMIRe) project has been endorsed by Japanese community as one of
the main future instruments of the Subaru 8.2-meter telescope at Mauna Kea,
Hawaii. This optical/near-infrared multi-fiber spectrograph targets cosmology
with galaxy surveys, Galactic archaeology, and studies of galaxy/AGN evolution.
Taking advantage of Subaru's wide field of view, which is further extended with
the recently completed Wide Field Corrector, PFS will enable us to carry out
multi-fiber spectroscopy of 2400 targets within 1.3 degree diameter. A
microlens is attached at each fiber entrance for F-ratio transformation into a
larger one so that difficulties of spectrograph design are eased. Fibers are
accurately placed onto target positions by positioners, each of which consists
of two stages of piezo-electric rotary motors, through iterations by using
back-illuminated fiber position measurements with a wide-field metrology
camera. Fibers then carry light to a set of four identical fast-Schmidt
spectrographs with three color arms each: the wavelength ranges from 0.38
{\mu}m to 1.3 {\mu}m will be simultaneously observed with an average resolving
power of 3000. Before and during the era of extremely large telescopes, PFS
will provide the unique capability of obtaining spectra of 2400
cosmological/astrophysical targets simultaneously with an 8-10 meter class
telescope. The PFS collaboration, led by IPMU, consists of USP/LNA in Brazil,
Caltech/JPL, Princeton, & JHU in USA, LAM in France, ASIAA in Taiwan, and
NAOJ/Subaru.
[7]
oai:arXiv.org:1110.3193 [pdf] - 429544
Euclid Definition Study Report
Laureijs, R.;
Amiaux, J.;
Arduini, S.;
Auguères, J. -L.;
Brinchmann, J.;
Cole, R.;
Cropper, M.;
Dabin, C.;
Duvet, L.;
Ealet, A.;
Garilli, B.;
Gondoin, P.;
Guzzo, L.;
Hoar, J.;
Hoekstra, H.;
Holmes, R.;
Kitching, T.;
Maciaszek, T.;
Mellier, Y.;
Pasian, F.;
Percival, W.;
Rhodes, J.;
Criado, G. Saavedra;
Sauvage, M.;
Scaramella, R.;
Valenziano, L.;
Warren, S.;
Bender, R.;
Castander, F.;
Cimatti, A.;
Fèvre, O. Le;
Kurki-Suonio, H.;
Levi, M.;
Lilje, P.;
Meylan, G.;
Nichol, R.;
Pedersen, K.;
Popa, V.;
Lopez, R. Rebolo;
Rix, H. -W.;
Rottgering, H.;
Zeilinger, W.;
Grupp, F.;
Hudelot, P.;
Massey, R.;
Meneghetti, M.;
Miller, L.;
Paltani, S.;
Paulin-Henriksson, S.;
Pires, S.;
Saxton, C.;
Schrabback, T.;
Seidel, G.;
Walsh, J.;
Aghanim, N.;
Amendola, L.;
Bartlett, J.;
Baccigalupi, C.;
Beaulieu, J. -P.;
Benabed, K.;
Cuby, J. -G.;
Elbaz, D.;
Fosalba, P.;
Gavazzi, G.;
Helmi, A.;
Hook, I.;
Irwin, M.;
Kneib, J. -P.;
Kunz, M.;
Mannucci, F.;
Moscardini, L.;
Tao, C.;
Teyssier, R.;
Weller, J.;
Zamorani, G.;
Osorio, M. R. Zapatero;
Boulade, O.;
Foumond, J. J.;
Di Giorgio, A.;
Guttridge, P.;
James, A.;
Kemp, M.;
Martignac, J.;
Spencer, A.;
Walton, D.;
Blümchen, T.;
Bonoli, C.;
Bortoletto, F.;
Cerna, C.;
Corcione, L.;
Fabron, C.;
Jahnke, K.;
Ligori, S.;
Madrid, F.;
Martin, L.;
Morgante, G.;
Pamplona, T.;
Prieto, E.;
Riva, M.;
Toledo, R.;
Trifoglio, M.;
Zerbi, F.;
Abdalla, F.;
Douspis, M.;
Grenet, C.;
Borgani, S.;
Bouwens, R.;
Courbin, F.;
Delouis, J. -M.;
Dubath, P.;
Fontana, A.;
Frailis, M.;
Grazian, A.;
Koppenhöfer, J.;
Mansutti, O.;
Melchior, M.;
Mignoli, M.;
Mohr, J.;
Neissner, C.;
Noddle, K.;
Poncet, M.;
Scodeggio, M.;
Serrano, S.;
Shane, N.;
Starck, J. -L.;
Surace, C.;
Taylor, A.;
Verdoes-Kleijn, G.;
Vuerli, C.;
Williams, O. R.;
Zacchei, A.;
Altieri, B.;
Sanz, I. Escudero;
Kohley, R.;
Oosterbroek, T.;
Astier, P.;
Bacon, D.;
Bardelli, S.;
Baugh, C.;
Bellagamba, F.;
Benoist, C.;
Bianchi, D.;
Biviano, A.;
Branchini, E.;
Carbone, C.;
Cardone, V.;
Clements, D.;
Colombi, S.;
Conselice, C.;
Cresci, G.;
Deacon, N.;
Dunlop, J.;
Fedeli, C.;
Fontanot, F.;
Franzetti, P.;
Giocoli, C.;
Garcia-Bellido, J.;
Gow, J.;
Heavens, A.;
Hewett, P.;
Heymans, C.;
Holland, A.;
Huang, Z.;
Ilbert, O.;
Joachimi, B.;
Jennins, E.;
Kerins, E.;
Kiessling, A.;
Kirk, D.;
Kotak, R.;
Krause, O.;
Lahav, O.;
van Leeuwen, F.;
Lesgourgues, J.;
Lombardi, M.;
Magliocchetti, M.;
Maguire, K.;
Majerotto, E.;
Maoli, R.;
Marulli, F.;
Maurogordato, S.;
McCracken, H.;
McLure, R.;
Melchiorri, A.;
Merson, A.;
Moresco, M.;
Nonino, M.;
Norberg, P.;
Peacock, J.;
Pello, R.;
Penny, M.;
Pettorino, V.;
Di Porto, C.;
Pozzetti, L.;
Quercellini, C.;
Radovich, M.;
Rassat, A.;
Roche, N.;
Ronayette, S.;
Rossetti, E.;
Sartoris, B.;
Schneider, P.;
Semboloni, E.;
Serjeant, S.;
Simpson, F.;
Skordis, C.;
Smadja, G.;
Smartt, S.;
Spano, P.;
Spiro, S.;
Sullivan, M.;
Tilquin, A.;
Trotta, R.;
Verde, L.;
Wang, Y.;
Williger, G.;
Zhao, G.;
Zoubian, J.;
Zucca, E.
Submitted: 2011-10-14
Euclid is a space-based survey mission from the European Space Agency
designed to understand the origin of the Universe's accelerating expansion. It
will use cosmological probes to investigate the nature of dark energy, dark
matter and gravity by tracking their observational signatures on the geometry
of the universe and on the cosmic history of structure formation. The mission
is optimised for two independent primary cosmological probes: Weak
gravitational Lensing (WL) and Baryonic Acoustic Oscillations (BAO). The Euclid
payload consists of a 1.2 m Korsch telescope designed to provide a large field
of view. It carries two instruments with a common field-of-view of ~0.54 deg2:
the visual imager (VIS) and the near infrared instrument (NISP) which contains
a slitless spectrometer and a three bands photometer. The Euclid wide survey
will cover 15,000 deg2 of the extragalactic sky and is complemented by two 20
deg2 deep fields. For WL, Euclid measures the shapes of 30-40 resolved galaxies
per arcmin2 in one broad visible R+I+Z band (550-920 nm). The photometric
redshifts for these galaxies reach a precision of dz/(1+z) < 0.05. They are
derived from three additional Euclid NIR bands (Y, J, H in the range 0.92-2.0
micron), complemented by ground based photometry in visible bands derived from
public data or through engaged collaborations. The BAO are determined from a
spectroscopic survey with a redshift accuracy dz/(1+z) =0.001. The slitless
spectrometer, with spectral resolution ~250, predominantly detects Ha emission
line galaxies. Euclid is a Medium Class mission of the ESA Cosmic Vision
2015-2025 programme, with a foreseen launch date in 2019. This report (also
known as the Euclid Red Book) describes the outcome of the Phase A study.
[8]
oai:arXiv.org:1105.2537 [pdf] - 1076591
GOODS-Herschel: an infrared main sequence for star-forming galaxies
Elbaz, D.;
Dickinson, M.;
Hwang, H. S.;
Diaz-Santos, T.;
Magdis, G.;
Magnelli, B.;
Borgne, D. Le;
Galliano, F.;
Pannella, M.;
Chanial, P.;
Armus, L.;
Charmandaris, V.;
Daddi, E.;
Aussel, H.;
Popesso, P.;
Kartaltepe, J.;
Altieri, B.;
Valtchanov, I.;
Coia, D.;
Dannerbauer, H.;
Dasyra, K.;
Leiton, R.;
Mazzarella, J.;
Buat, V.;
Burgarella, D.;
Chary, R. -R.;
Gilli, R.;
Ivison, R. J.;
Juneau, S.;
LeFloc'h, E.;
Lutz, D.;
Morrison, G. E.;
Mullaney, J.;
Murphy, E.;
Pope, A.;
Scott, D.;
Alexander, D.;
Brodwin, M.;
Calzetti, D.;
Cesarsky, C.;
Charlot, S.;
Dole, H.;
Eisenhardt, P.;
Ferguson, H. C.;
Foerster-Schreiber, N.;
Frayer, D.;
Giavalisco, M.;
Huynh, M.;
Koekemoer, A. M.;
Papovich, C.;
Reddy, N.;
Surace, C.;
Teplitz, H.;
Yun, M. S.;
Wilson, G.
Submitted: 2011-05-12, last modified: 2011-09-13
We present the deepest far-IR observations obtained with Herschel and examine
the 3-500um SEDs of galaxies at 0<z<2.5, supplemented by a local reference
sample from IRAS, ISO, Spitzer and AKARI data. We find that the ratio of total
IR luminosity to rest-frame 8um luminosity, IR8 (=Lir/L8), follows a Gaussian
distribution centered on IR8=4 and defines an IR main sequence (MS). A minority
population (<20 %) of outliers producing a tail skewed toward higher values of
IR8 consist of starbursts (SB) with compact projected star formation densities.
IR8 can be used to separate galaxies with normal and extended modes of star
formation from compact SBs with high-IR8, high projected IR surface brightness
(>3x10^10 Lsun kpc^-2) and a high specific SFR (i.e., SBs). The rest-frame,
UV-2700A size of these distant SBs is typically half that of MS galaxies,
supporting the correlation between star formation density and SB activity that
is measured for the local sample. Locally, (U)LIRGs are systematically in the
SB mode, whereas most distant (U)LIRGs form stars in the "normal" MS mode. This
confusion between two modes of star formation is the cause of the so-called
"mid-IR excess" population of galaxies found at z>1.5 by previous studies. MS
galaxies have strong PAH emission line features, a broad far-IR bump resulting
from a combination of dust temperatures (Tdust~15-50 K), and an effective
Tdust~31 K, as derived from the peak wavelength of their IR SED. Galaxies in
the SB regime instead exhibit weak PAH EW and a sharper far-IR bump with an
effective Tdust~40 K. Finally, we present evidence that the mid-to-far IR
emission of X-ray AGNs is predominantly produced by star formation and that
candidate dusty AGNs with a power-law emission in the mid-IR systematically
occur in compact, dusty SBs. After correcting for the effect of SBs on IR8, we
identify new candidates for extremely obscured AGNs.
[9]
oai:arXiv.org:1005.5123 [pdf] - 1032799
The Herschel-SPIRE instrument and its in-flight performance
Griffin, M. J.;
Abergel, A.;
Abreu, A.;
Ade, P. A. R.;
André, P.;
Augueres, J. -L.;
Babbedge, T.;
Bae, Y.;
Baillie, T.;
Baluteau, J. -P.;
Barlow, M. J.;
Bendo, G.;
Benielli, D.;
Bock, J. J.;
Bonhomme, P.;
Brisbin, D.;
Brockley-Blatt, C.;
Caldwell, M.;
Cara, C.;
Castro-Rodriguez, N.;
Cerulli, R.;
Chanial, P.;
Chen, S.;
Clark, E.;
Clements, D. L.;
Clerc, L.;
Coker, J.;
Communal, D.;
Conversi, L.;
Cox, P.;
Crumb, D.;
Cunningham, C.;
Daly, F.;
Davis, G. R.;
De Antoni, P.;
Delderfield, J.;
Devin, N.;
Di Giorgio, A.;
Didschuns, I.;
Dohlen, K.;
Donati, M.;
Dowell, A.;
Dowell, C. D.;
Duband, L.;
Dumaye, L.;
Emery, R. J.;
Ferlet, M.;
Ferrand, D.;
Fontignie, J.;
Fox, M.;
Franceschini, A.;
Frerking, M.;
Fulton, T.;
Garcia, J.;
Gastaud, R.;
Gear, W. K.;
Glenn, J.;
Goizel, A.;
Griffin, D. K.;
Grundy, T.;
Guest, S.;
Guillemet, L.;
Hargrave, P. C.;
Harwit, M.;
Hastings, P.;
Hatziminaoglou, E.;
Herman, M.;
Hinde, B.;
Hristov, V.;
Huang, M.;
Imhof, P.;
Isaak, K. J.;
Israelsson, U.;
Ivison, R. J.;
Jennings, D.;
Kiernan, B.;
King, K. J.;
Lange, A. E.;
Latter, W.;
Laurent, G.;
Laurent, P.;
Leeks, S. J.;
Lellouch, E.;
Levenson, L.;
Li, B.;
Li, J.;
Lilienthal, J.;
Lim, T.;
Liu, J.;
Lu, N.;
Madden, S.;
Mainetti, G.;
Marliani, P.;
McKay, D.;
Mercier, K.;
Molinari, S.;
Morris, H.;
Moseley, H.;
Mulder, J.;
Mur, M.;
Naylor, D. A.;
Nguyen, H.;
O'Halloran, B.;
Oliver, S.;
Olofsson, G.;
Olofsson, H. -G.;
Orfei, R.;
Page, M. J.;
Pain, I.;
Panuzzo, P.;
Papageorgiou, A.;
Parks, G.;
Parr-Burman, P.;
Pearce, A.;
Pearson, C.;
Pérez-Fournon, I.;
Pinsard, F.;
Pisano, G.;
Podosek, J.;
Pohlen, M.;
Polehampton, E. T.;
Pouliquen, D.;
Rigopoulou, D.;
Rizzo, D.;
Roseboom, I. G.;
Roussel, H.;
Rowan-Robinson, M.;
Rownd, B.;
Saraceno, P.;
Sauvage, M.;
Savage, R.;
Savini, G.;
Sawyer, E.;
Scharmberg, C.;
Schmitt, D.;
Schneider, N.;
Schulz, B.;
Schwartz, A.;
Shafer, R.;
Shupe, D. L.;
Sibthorpe, B.;
Sidher, S.;
Smith, A.;
Smith, A. J.;
Smith, D.;
Spencer, L.;
Stobie, B.;
Sudiwala, R.;
Sukhatme, K.;
Surace, C.;
Stevens, J. A.;
Swinyard, B. M.;
Trichas, M.;
Tourette, T.;
Triou, H.;
Tseng, S.;
Tucker, C.;
Turner, A.;
Vaccari, M.;
Valtchanov, I.;
Vigroux, L.;
Virique, E.;
Voellmer, G.;
Walker, H.;
Ward, R.;
Waskett, T.;
Weilert, M.;
Wesson, R.;
White, G. J.;
Whitehouse, N.;
Wilson, C. D.;
Winter, B.;
Woodcraft, A. L.;
Wright, G. S.;
Xu, C. K.;
Zavagno, A.;
Zemcov, M.;
Zhang, L.;
Zonca, E.
Submitted: 2010-05-27
The Spectral and Photometric Imaging Receiver (SPIRE), is the Herschel Space
Observatory`s submillimetre camera and spectrometer. It contains a three-band
imaging photometer operating at 250, 350 and 500 microns, and an imaging
Fourier Transform Spectrometer (FTS) which covers simultaneously its whole
operating range of 194-671 microns (447-1550 GHz). The SPIRE detectors are
arrays of feedhorn-coupled bolometers cooled to 0.3 K. The photometer has a
field of view of 4' x 8', observed simultaneously in the three spectral bands.
Its main operating mode is scan-mapping, whereby the field of view is scanned
across the sky to achieve full spatial sampling and to cover large areas if
desired. The spectrometer has an approximately circular field of view with a
diameter of 2.6'. The spectral resolution can be adjusted between 1.2 and 25
GHz by changing the stroke length of the FTS scan mirror. Its main operating
mode involves a fixed telescope pointing with multiple scans of the FTS mirror
to acquire spectral data. For extended source measurements, multiple position
offsets are implemented by means of an internal beam steering mirror to achieve
the desired spatial sampling and by rastering of the telescope pointing to map
areas larger than the field of view. The SPIRE instrument consists of a cold
focal plane unit located inside the Herschel cryostat and warm electronics
units, located on the spacecraft Service Module, for instrument control and
data handling. Science data are transmitted to Earth with no on-board data
compression, and processed by automatic pipelines to produce calibrated science
products. The in-flight performance of the instrument matches or exceeds
predictions based on pre-launch testing and modelling: the photometer
sensitivity is comparable to or slightly better than estimated pre-launch, and
the spectrometer sensitivity is also better by a factor of 1.5-2.
[10]
oai:arXiv.org:astro-ph/0410379 [pdf] - 68228
The European Large Area ISO Survey VIII: 90-micron final analysis and
source counts
Heraudeau, Ph.;
Oliver, S.;
del Burgo, C.;
Kiss, C.;
Stickel, M.;
Mueller, T.;
Rowan-Robinson, M.;
Efstathiou, A.;
Surace, C.;
Toth, L. V.;
Serjeant, S.;
Alexander, D. M.;
Franceschini, A.;
Lemke, D.;
Perez-Fournon, I.;
Morel, T.;
Puget, J-L.;
Rigopoulou, D.;
Rocca-Volmerange, B.;
Verma, A.
Submitted: 2004-10-15
We present a re--analysis of the European Large Area ISO Survey (ELAIS) 90mum
observations carried out with ISOPHOT, an instrument on board the ESA's
Infrared Space Observatory (ISO). With more than 12 sq. deg., the ELAIS survey
is the largest area covered by ISO in a single program and is about one order
of magnitude deeper than the IRAS 100mum survey. The data analysis is presented
and was mainly performed with the Phot Interactive Analysis software but using
the pairwise method of Stickel et al. (2003) for signal processing from ERD
(Edited Raw Data) to SCP (Signal per Chopper Plateau). The ELAIS 90mum
catalogue contains 229 reliable sources with fluxes larger than 70 mJy and is
available at www.blackwell-synergy.com. Number counts are presented and show an
excess above the no-evolution model prediction. This confirms the strong
evolution detected at shorter(15mum) and longer (170mum) wavelengths in other
ISO surveys. The ELAIS counts are in agreement with previous works at 90mum and
in particular with the deeper counts extracted from the Lockman hole
observations. Comparison with recent evolutionary models show that the models
of Franceschini et al. and Guiderdoni et al. which includes a
heavily-extinguished population of galaxies give the best fit to the data.
Deeper observations are nevertheless required to better discriminate between
the model predictions in the far-infrared and are scheduled with the Spitzer
Space Telescope which already started operating and will also be performed by
ASTRO-F.
[11]
oai:arXiv.org:astro-ph/0107148 [pdf] - 43519
The European Large Area ISO Survey VI - Discovery of a new hyperluminous
infrared galaxy
Morel, T.;
Efstathiou, A.;
Serjeant, S.;
Marquez, I.;
Masegosa, J.;
Heraudeau, P.;
Surace, C.;
Verma, A.;
Oliver, S.;
Rowan-Robinson, M.;
Georgantopoulos, I.;
Farrah, D.;
Alexander, D. M.;
Perez-Fournon, I.;
Willott, C. J.;
Cabrera-Guerra, F.;
Gonzalez-Solares, E. A.;
Cabrera-Lavers, A.;
Gonzalez-Serrano, J. I.;
Ciliegi, P.;
Pozzi, F.;
Matute, I.;
Flores, H.
Submitted: 2001-07-09
We report the discovery of the first hyperluminous infrared galaxy (HyLIG) in
the course of the European Large Area ISO Survey (ELAIS). This object has been
detected by ISO at 6.7, 15, and 90 microns, and is found to be a broad-line,
radio-quiet quasar at a redshift: z = 1.099. From a detailed multi-component
model fit of the spectral energy distribution, we derive a total infrared
luminosity: L_IR (1-1000 microns) ~ 1.0 x 10E13 h_65^-2 L_sun (q_0 = 0.5), and
discuss the possible existence of a starburst contributing to the far-IR
output. Observations to date present no evidence for lens magnification. This
galaxy is one of the very few HyLIGs with an X-ray detection. On the basis of
its soft X-ray properties, we suggest that this broad-line object may be the
face-on analogue of narrow-line, Seyfert-like HyLIGs.
[12]
oai:arXiv.org:astro-ph/0010025 [pdf] - 38373
The European Large Area ISO Survey IV: the preliminary 90 micron
luminosity function
Serjeant, S.;
Efstathiou, A.;
Oliver, S.;
Surace, C.;
Heraudeau, P.;
Linden-Vornle, M.;
Gruppioni, C.;
La Franca, F.;
Rigopoulou, D.;
Morel, T.;
Crockett, H.;
Sumner, T.;
Rowan-Robinson, M.;
Graham, M.
Submitted: 2000-10-02
We present the luminosity function of 90um selected galaxies from the
European Large Area ISO Survey (ELAIS), extending to z=0.3. Their luminosities
are in the range 10^9 < h_65^-2 L/Lsun < 10^12, i.e. non-ultraluminous. From
our sample of 37 reliably detected galaxies in the ELAIS S1 region from the
Efstathiou et al. (2000) S_90 >= 100mJy database, we found optical, 15um or
1.4GHz identifications for 24 (65%). We have obtained 2dF and UK Schmidt FLAIR
spectroscopy of 89% of IDs to rigid multivariate flux limits. We construct a
luminosity function assuming (a) our spectroscopic subset is an unbiased sparse
sample, and (b) there are no galaxies which would not be represented in our
spectroscopic sample at {\it any} redshift. We argue that we can be confident
of both assumptions. We find the luminosity function is well-described by the
local 100um luminosity function of Rowan-Robinson, Helou & Walker (1987). {\it
Assuming} this local normalisation, we derive luminosity evolution of
(1+z)^{2.45\pm0.85} (95% confidence). We argue that star formation dominates
the bolometric luminosities of these galaxies and we derive comoving star
formation rates in broad agreement with the Flores et al. (1999) and
Rowan-Robinson et al. (1997) mid-IR-based estimates.
[13]
oai:arXiv.org:astro-ph/0008065 [pdf] - 1943527
The European Large Area ISO Survey III: 90micron extragalactic source
counts
Efstathiou, A.;
Oliver, S.;
Rowan-Robinson, M.;
Surace, C.;
Sumner, T.;
Heraudeau, P.;
Linden-Vornle, M. J. D.;
Rigopoulou, D.;
Serjeant, S.;
Mann, R. G.;
Cesarsky, C. J.;
Danese, L.;
Franceschini, A.;
Genzel, R.;
Lawrence, A.;
Lemke, D.;
McMahon, R. G.;
Miley, G.;
Puget, J-L.;
Rocca-Volmerange, B.
Submitted: 2000-08-03
We present results and source counts at 90micron extracted from the
Preliminary Analysis of the European Large Area ISO Survey (ELAIS). The survey
covered about 11.6 square degrees of the sky in four main areas and was carried
out with the PHOT instrument onboard the Infrared Space Observatory (ISO). The
survey is at least an order of magnitude deeper than the IRAS 100micron survey
and is expected to provide constraints on the formation and evolution of
galaxies. The majority of the detected sources are associated with galaxies on
optical images. In some cases the optical associations are interacting pairs or
small groups of galaxies suggesting the sample may include a significant
fraction of luminous infrared galaxies. The source counts extracted from a
reliable subset of the detected sources are in agreement with strongly evolving
models of the starburst galaxy population.
[14]
oai:arXiv.org:astro-ph/9906273 [pdf] - 1943627
The European Large Area ISO Survey: ELAIS
Rowan-Robinson, M.;
Oliver, S.;
Efstathiou, A.;
Gruppioni, C.;
Serjeant, S.;
Cesarsky, C.;
Danese, L.;
Franceschini, A.;
Genzel, R.;
Lawrence, A.;
Lemke, D.;
McMahon, R.;
Miley, G.;
Perez-Fournon, I.;
Puget, J. -L.;
Rocca-Volmerange, B.;
Cileigi, P.;
Heraudeau, P.;
Surace, C.;
LaFranca, F.
Submitted: 1999-06-16
The European Large Area ISO Survey (ELAIS) has surveyed 12 square degrees of
the sky at 15 and 90 microns, and subsets of this area at 6.75 and 175 microns,
using the Infrared Space Observatory (ISO). This project was the largest single
open time programme executed by ISO, taking 375 hours of data. A preliminary
catalogue of more than 1000 galaxies has been produced. In this talk we
describe the goals of the project, describe the follow-up programmes that are
in progress, and present some first scientific results including a provisional
number count analysis at 15 and 90 microns.
[15]
oai:arXiv.org:astro-ph/9812127 [pdf] - 104234
The European Large Area ISO Survey - ISOPHOT results using the
MPIA-pipeline
Submitted: 1998-12-07
The European Large Area ISO Survey (ELAIS) will provide Infrared observations
of 4 regions in the sky with ISO. Around 2000 Infrared sources have been
detected at 7 and 15 microns (with ISOCAM), 90 and 175 microns (with ISOPHOT))
over 13 square degrees of the sky. We present the source extraction pipeline of
the 90 microns ISOPHOT observations, describe and discuss the results obtained
and derive the limits of the ELAIS observational strategy.
[16]
oai:arXiv.org:astro-ph/9806069 [pdf] - 101662
The Marseille Schmidt survey for active star-forming galaxies. I. Data
on 92 emission line objects in two fields
Submitted: 1998-06-04
We present data from a moderately deep spectroscopic Schmidt survey
(Blim=17.5) of ``active galaxies'' selected by the presence of emission lines
in their spectra and/or their UV excess. The redshift, magnitudes, color and
diameter reduction methods have been discussed in a previous paper. Here we
explain the emission line equivalent width determination method. 92 emission
line objects have been found in two adjacent fields (approximately 50deg^2) in
the direction of the south extension of the Virgo cluster. We give a catalog
containing positions, photographic R and B magnitudes, U-R colors, effective
diameters, redshifts, equivalent widths and intensity ratios of the
[OIII]4959,5007, Hbeta and [OII] 3727 emission lines. On these fields, we
evaluate the completeness limit of the survey at a pseudo B magnitude value of
15.7.