sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Sumner, Timothy J.

Normalized to: Sumner, T.

72 article(s) in total. 1201 co-authors, from 1 to 29 common article(s). Median position in authors list is 57,5.

[1]  oai:arXiv.org:2005.03423  [pdf] - 2091265
Spacecraft and interplanetary contributions to the magnetic environment on-board LISA Pathfinder
Comments: 16 pages, 17 figures. MNRAS LaTeX style file version 3.0
Submitted: 2020-05-07
LISA Pathfinder (LPF) has been a space-based mission designed to test new technologies that will be required for a gravitational wave observatory in space. Magnetically driven forces play a key role in the instrument sensitivity in the low-frequency regime (mHz and below), the measurement band of interest for a space-based observatory. The magnetic field can couple to the magnetic susceptibility and remanent magnetic moment from the test masses and disturb them from their geodesic movement. LISA Pathfinder carried on-board a dedicated magnetic measurement subsystem with noise levels of 10 $ \rm nT \ Hz^{-1/2}$ from 1 Hz down to 1 mHz. In this paper we report on the magnetic measurements throughout LISA Pathfinder operations. We characterise the magnetic environment within the spacecraft, study the time evolution of the magnetic field and its stability down to 20 $\mu$Hz, where we measure values around 200 $ \rm nT \ Hz^{-1/2}$ and identify two different frequency regimes, one related to the interplanetary magnetic field and the other to the magnetic field originating inside the spacecraft. Finally, we characterise the non-stationary component of the fluctuations of the magnetic field below the mHz and relate them to the dynamics of the solar wind.
[2]  oai:arXiv.org:2003.11141  [pdf] - 2070172
An Effective Field Theory Analysis of the First LUX Dark Matter Search
Comments: 11 pages, 6 figures
Submitted: 2020-03-24
The Large Underground Xenon (LUX) dark matter search was a 250-kg active mass dual-phase time projection chamber that operated by detecting light and ionization signals from particles incident on a xenon target. In December 2015, LUX reported a minimum 90% upper C.L. of 6e-46 cm^2 on the spin-independent WIMP-nucleon elastic scattering cross section based on a 1.4e4 kg*day exposure in its first science run. Tension between experiments and the absence of a definitive positive detection suggest it would be prudent to search for WIMPs outside the standard spin-independent/spin-dependent paradigm. Recent theoretical work has identified a complete basis of 14 independent effective field theory (EFT) operators to describe WIMP-nucleon interactions. In addition to spin-independent and spin-dependent nuclear responses, these operators can produce novel responses such as angular-momentum-dependent and spin-orbit couplings. Here we report on a search for all 14 of these EFT couplings with data from LUX's first science run. Limits are placed on each coupling as a function of WIMP mass.
[3]  oai:arXiv.org:1907.06272  [pdf] - 2050176
Extending light WIMP searches to single scintillation photons in LUX
Akerib, D. S.; Alsum, S.; Araújo, H. M.; Bai, X.; Bailey, A. J.; Balajthy, J.; Baxter, A.; Beltrame, P.; Bernard, E. P.; Bernstein, A.; Biesiadzinski, T. P.; Boulton, E. M.; Boxer, B.; Brás, P.; Burdin, S.; Byram, D.; Cahn, S. B.; Carmona-Benitez, M. C.; Chan, C.; Chiller, A. A.; Chiller, C.; Currie, A.; Cutter, J. E.; de Viveiros, L.; Dobi, A.; Dobson, J. E. Y.; Druszkiewicz, E.; Edwards, B. N.; Faham, C. H.; Fallon, S. R.; Fan, A.; Fiorucci, S.; Gaitskell, R. J.; Gehman, V. M.; Genovesi, J.; Ghag, C.; Gibson, K. R.; Gilchriese, M. G. D.; Grace, E.; Gwilliam, C.; Hall, C. R.; Hanhardt, M.; Haselschwardt, S. J.; Hertel, S. A.; Hogan, D. P.; Horn, M.; Huang, D. Q.; Ignarra, C. M.; Jacobsen, R. G.; Jahangir, O.; Ji, W.; Kamdin, K.; Kazka, K.; Khaitan, D.; Knoche, R.; Korolkova, E. V.; Kravitz, S.; Kudryavtsev, V. A.; Larsen, N. A.; Leason, E.; Lee, C.; Lenardo, B. G.; Lesko, K. T.; Levy, C.; Liao, J.; Lin, J.; Lindote, A.; Lopes, M. I.; López-Paredes, B.; Manalaysay, A.; Mannino, R. L.; Marangou, N.; Marzioni, M. F.; McKinsey, D. N.; Mei, D. M.; Mock, J.; Moongweluwan, M.; Morad, J. A.; Murphy, A. St. J.; Naylor, A.; Nehrkorn, C.; Nelson, H. N.; Neves, F.; Nilima, A.; O'Sullivan, K.; Oliver-Mallory, K. C.; Palladino, K. J.; Pease, E. K.; Reichhart, L.; Riffard, Q.; Rischbieter, G. R. C.; Rossiter, P.; Shaw, S.; Shutt, T. A.; Silva, C.; Solmaz, M.; Solovov, V. N.; Sorensen, P.; Stephenson, S.; Sumner, T. J.; Szydagis, M.; Taylor, D. J.; Taylor, R.; Taylor, W. C.; Tennyson, B. P.; Terman, P. A.; Tiedt, D. R.; To, W. H.; Tripathi, M.; Tvrznikova, L.; Utku, U.; Uvarov, S.; Vacheret, A.; Velan, V.; Verbus, J. R.; Webb, R. C.; White, J. T.; Whitis, T. J.; Witherell, M. S.; Wolfs, F. L. H.; Woodward, D.; Xu, J.; Yazdani, K.; Young, S. K.; Zhang, C.
Comments:
Submitted: 2019-07-14, last modified: 2019-12-27
We present a novel analysis technique for liquid xenon time projection chambers that allows for a lower threshold by relying on events with a prompt scintillation signal consisting of single detected photons. The energy threshold of the LUX dark matter experiment is primarily determined by the smallest scintillation response detectable, which previously required a 2-fold coincidence signal in its photomultiplier arrays, enforced in data analysis. The technique presented here exploits the double photoelectron emission effect observed in some photomultiplier models at vacuum ultraviolet wavelengths. We demonstrate this analysis using an electron recoil calibration dataset and place new constraints on the spin-independent scattering cross section of weakly interacting massive particles (WIMPs) down to 2.5 GeV/c$^2$ WIMP mass using the 2013 LUX dataset. This new technique is promising to enhance light WIMP and astrophysical neutrino searches in next-generation liquid xenon experiments.
[4]  oai:arXiv.org:1908.11785  [pdf] - 2013830
Exploring the Foundations of the Universe with Space Tests of the Equivalence Principle
Comments: White paper submitted to the ESA Voyage 2050 long term plan. Partly derived from Altschul et al., Advances in Space Research, 2015, 55, 501 - 524, arXiv:1404.4307
Submitted: 2019-08-30, last modified: 2019-12-12
We present the scientific motivation for future space tests of the equivalence principle, and in particular the universality of free fall, at the $10^{-17}$ level or better. Two possible mission scenarios, one based on quantum technologies, the other on electrostatic accelerometers, that could reach that goal are briefly discussed.
[5]  oai:arXiv.org:1910.09124  [pdf] - 1990394
The LUX-ZEPLIN (LZ) Experiment
The LZ Collaboration; Akerib, D. S.; Akerlof, C. W.; Akimov, D. Yu.; Alquahtani, A.; Alsum, S. K.; Anderson, T. J.; Angelides, N.; Araújo, H. M.; Arbuckle, A.; Armstrong, J. E.; Arthurs, M.; Auyeung, H.; Bai, X.; Bailey, A. J.; Balajthy, J.; Balashov, S.; Bang, J.; Barry, M. J.; Barthel, J.; Bauer, D.; Bauer, P.; Baxter, A.; Belle, J.; Beltrame, P.; Bensinger, J.; Benson, T.; Bernard, E. P.; Bernstein, A.; Bhatti, A.; Biekert, A.; Biesiadzinski, T. P.; Birrittella, B.; Boast, K. E.; Bolozdynya, A. I.; Boulton, E. M.; Boxer, B.; Bramante, R.; Branson, S.; Brás, P.; Breidenbach, M.; Buckley, J. H.; Bugaev, V. V.; Bunker, R.; Burdin, S.; Busenitz, J. K.; Campbell, J. S.; Carels, C.; Carlsmith, D. L.; Carlson, B.; Carmona-Benitez, M. C.; Cascella, M.; Chan, C.; Cherwinka, J. J.; Chiller, A. A.; Chiller, C.; Chott, N. I.; Cole, A.; Coleman, J.; Colling, D.; Conley, R. A.; Cottle, A.; Coughlen, R.; Craddock, W. W.; Curran, D.; Currie, A.; Cutter, J. E.; da Cunha, J. P.; Dahl, C. E.; Dardin, S.; Dasu, S.; Davis, J.; Davison, T. J. R.; de Viveiros, L.; Decheine, N.; Dobi, A.; Dobson, J. E. Y.; Druszkiewicz, E.; Dushkin, A.; Edberg, T. K.; Edwards, W. R.; Edwards, B. N.; Edwards, J.; Elnimr, M. M.; Emmet, W. T.; Eriksen, S. R.; Faham, C. H.; Fan, A.; Fayer, S.; Fiorucci, S.; Flaecher, H.; Florang, I. M. Fogarty; Ford, P.; Francis, V. B.; Froborg, F.; Fruth, T.; Gaitskell, R. J.; Gantos, N. J.; Garcia, D.; Geffre, A.; Gehman, V. M.; Gelfand, R.; Genovesi, J.; Gerhard, R. M.; Ghag, C.; Gibson, E.; Gilchriese, M. G. D.; Gokhale, S.; Gomber, B.; Gonda, T. G.; Greenall, A.; Greenwood, S.; Gregerson, G.; van der Grinten, M. G. D.; Gwilliam, C. B.; Hall, C. R.; Hamilton, D.; Hans, S.; Hanzel, K.; Harrington, T.; Harrison, A.; Hasselkus, C.; Haselschwardt, S. J.; Hemer, D.; Hertel, S. A.; Heise, J.; Hillbrand, S.; Hitchcock, O.; Hjemfelt, C.; Hoff, M. D.; Holbrook, B.; Holtom, E.; Hor, J. Y-K.; Horn, M.; Huang, D. Q.; Hurteau, T. W.; Ignarra, C. M.; Irving, M. N.; Jacobsen, R. G.; Jahangir, O.; Jeffery, S. N.; Ji, W.; Johnson, M.; Johnson, J.; Johnson, P.; Jones, W. G.; Kaboth, A. C.; Kamaha, A.; Kamdin, K.; Kasey, V.; Kazkaz, K.; Keefner, J.; Khaitan, D.; Khaleeq, M.; Khazov, A.; Khromov, A. V.; Khurana, I.; Kim, Y. D.; Kim, W. T.; Kocher, C. D.; Konovalov, A. M.; Korley, L.; Korolkova, E. V.; Koyuncu, M.; Kras, J.; Kraus, H.; Kravitz, S. W.; Krebs, H. J.; Kreczko, L.; Krikler, B.; Kudryavtsev, V. A.; Kumpan, A. V.; Kyre, S.; Lambert, A. R.; Landerud, B.; Larsen, N. A.; Laundrie, A.; Leason, E. A.; Lee, H. S.; Lee, J.; Lee, C.; Lenardo, B. G.; Leonard, D. S.; Leonard, R.; Lesko, K. T.; Levy, C.; Li, J.; Liu, Y.; Liao, J.; Liao, F. -T.; Lin, J.; Lindote, A.; Linehan, R.; Lippincott, W. H.; Liu, R.; Liu, X.; Loniewski, C.; Lopes, M. I.; Paredes, B. López; Lorenzon, W.; Lucero, D.; Luitz, S.; Lyle, J. M.; Lynch, C.; Majewski, P. A.; Makkinje, J.; Malling, D. C.; Manalaysay, A.; Manenti, L.; Mannino, R. L.; Marangou, N.; Markley, D. J.; MarrLaundrie, P.; Martin, T. J.; Marzioni, M. F.; Maupin, C.; McConnell, C. T.; McKinsey, D. N.; McLaughlin, J.; Mei, D. -M.; Meng, Y.; Miller, E. H.; Minaker, Z. J.; Mizrachi, E.; Mock, J.; Molash, D.; Monte, A.; Monzani, M. E.; Morad, J. A.; Morrison, E.; Mount, B. J.; Murphy, A. St. J.; Naim, D.; Naylor, A.; Nedlik, C.; Nehrkorn, C.; Nelson, H. N.; Nesbit, J.; Neves, F.; Nikkel, J. A.; Nikoleyczik, J. A.; Nilima, A.; O'Dell, J.; Oh, H.; O'Neill, F. G.; O'Sullivan, K.; Olcina, I.; Olevitch, M. A.; Oliver-Mallory, K. C.; Oxborough, L.; Pagac, A.; Pagenkopf, D.; Pal, S.; Palladino, K. J.; Palmaccio, V. M.; Palmer, J.; Pangilinan, M.; Patton, S. J.; Pease, E. K.; Penning, B. P.; Pereira, G.; Pereira, C.; Peterson, I. B.; Piepke, A.; Pierson, S.; Powell, S.; Preece, R. M.; Pushkin, K.; Qie, Y.; Racine, M.; Ratcliff, B. N.; Reichenbacher, J.; Reichhart, L.; Rhyne, C. A.; Richards, A.; Riffard, Q.; Rischbieter, G. R. C.; Rodrigues, J. P.; Rose, H. J.; Rosero, R.; Rossiter, P.; Rucinski, R.; Rutherford, G.; Rynders, D.; Saba, J. S.; Sabarots, L.; Santone, D.; Sarychev, M.; Sazzad, A. B. M. R.; Schnee, R. W.; Schubnell, M.; Scovell, P. R.; Severson, M.; Seymour, D.; Shaw, S.; Shutt, G. W.; Shutt, T. A.; Silk, J. J.; Silva, C.; Skarpaas, K.; Skulski, W.; Smith, A. R.; Smith, R. J.; Smith, R. E.; So, J.; Solmaz, M.; Solovov, V. N.; Sorensen, P.; Sosnovtsev, V. V.; Stancu, I.; Stark, M. R.; Stephenson, S.; Stern, N.; Stevens, A.; Stiegler, T. M.; Stifter, K.; Studley, R.; Sumner, T. J.; Sundarnath, K.; Sutcliffe, P.; Swanson, N.; Szydagis, M.; Tan, M.; Taylor, W. C.; Taylor, R.; Taylor, D. J.; Temples, D.; Tennyson, B. P.; Terman, P. A.; Thomas, K. J.; Thomson, J. A.; Tiedt, D. R.; Timalsina, M.; To, W. H.; Tomás, A.; Tope, T. E.; Tripathi, M.; Tronstad, D. R.; Tull, C. E.; Turner, W.; Tvrznikova, L.; Utes, M.; Utku, U.; Uvarov, S.; Va'vra, J.; Vacheret, A.; Vaitkus, A.; Verbus, J. R.; Vietanen, T.; Voirin, E.; Vuosalo, C. O.; Walcott, S.; Waldron, W. L.; Walker, K.; Wang, J. J.; Wang, R.; Wang, L.; Wang, Y.; Watson, J. R.; Migneault, J.; Weatherly, S.; Webb, R. C.; Wei, W. -Z.; While, M.; White, R. G.; White, J. T.; White, D. T.; Whitis, T. J.; Wisniewski, W. J.; Wilson, K.; Witherell, M. S.; Wolfs, F. L. H.; Wolfs, J. D.; Woodward, D.; Worm, S. D.; Xiang, X.; Xiao, Q.; Xu, J.; Yeh, M.; Yin, J.; Young, I.; Zhang, C.
Comments:
Submitted: 2019-10-20, last modified: 2019-11-03
We describe the design and assembly of the LUX-ZEPLIN experiment, a direct detection search for cosmic WIMP dark matter particles. The centerpiece of the experiment is a large liquid xenon time projection chamber sensitive to low energy nuclear recoils. Rejection of backgrounds is enhanced by a Xe skin veto detector and by a liquid scintillator Outer Detector loaded with gadolinium for efficient neutron capture and tagging. LZ is located in the Davis Cavern at the 4850' level of the Sanford Underground Research Facility in Lead, South Dakota, USA. We describe the major subsystems of the experiment and its key design features and requirements.
[6]  oai:arXiv.org:1811.11241  [pdf] - 1981692
Results of a Search for Sub-GeV Dark Matter Using 2013 LUX Data
Comments:
Submitted: 2018-11-27, last modified: 2019-10-16
The scattering of dark matter (DM) particles with sub-GeV masses off nuclei is difficult to detect using liquid xenon-based DM search instruments because the energy transfer during nuclear recoils is smaller than the typical detector threshold. However, the tree-level DM-nucleus scattering diagram can be accompanied by simultaneous emission of a Bremsstrahlung photon or a so-called "Migdal" electron. These provide an electron recoil component to the experimental signature at higher energies than the corresponding nuclear recoil. The presence of this signature allows liquid xenon detectors to use both the scintillation and the ionization signals in the analysis where the nuclear recoil signal would not be otherwise visible. We report constraints on spin-independent DM-nucleon scattering for DM particles with masses of 0.4-5 GeV/c$^2$ using 1.4$\times10^4$ kg$\cdot$day of search exposure from the 2013 data from the Large Underground Xenon (LUX) experiment for four different classes of mediators. This analysis extends the reach of liquid xenon-based DM search instruments to lower DM masses than has been achieved previously.
[7]  oai:arXiv.org:1908.00802  [pdf] - 1977400
AEDGE: Atomic Experiment for Dark Matter and Gravity Exploration in Space
El-Neaj, Yousef Abou; Alpigiani, Cristiano; Amairi-Pyka, Sana; Araujo, Henrique; Balaz, Antun; Bassi, Angelo; Bathe-Peters, Lars; Battelier, Baptiste; Belic, Aleksandar; Bentine, Elliot; Bernabeu, Jose; Bertoldi, Andrea; Bingham, Robert; Blas, Diego; Bolpasi, Vasiliki; Bongs, Kai; Bose, Sougato; Bouyer, Philippe; Bowcock, Themis; Bowden, William; Buchmueller, Oliver; Burrage, Clare; Calmet, Xavier; Canuel, Benjamin; Caramete, Laurentiu-Ioan; Carroll, Andrew; Cella, Giancarlo; Charmandaris, Vassilis; Chattopadhyay, Swapan; Chen, Xuzong; Chiofalo, Maria Luisa; Coleman, Jonathon; Cotter, Joseph; Cui, Yanou; Derevianko, Andrei; De Roeck, Albert; Djordjevic, Goran; Dornan, Peter; Doser, Michael; Drougkakis, Ioannis; Dunningham, Jacob; Dutan, Ioana; Easo, Sajan; Elertas, Gedminas; Ellis, John; Sawy, Mai El; Fassi, Farida; Felea, Daniel; Feng, Chen-Hao; Flack, Robert; Foot, Chris; Fuentes, Ivette; Gaaloul, Naceur; Gauguet, Alexandre; Geiger, Remi; Gibson, Valerie; Giudice, Gian; Goldwin, Jon; Grachov, Oleg; Graham, Peter W.; Grasso, Dario; van der Grinten, Maurits; Gundogan, Mustafa; Haehnelt, Martin G.; Harte, Tiffany; Hees, Aurelien; Hobson, Richard; Holst, Bodil; Hogan, Jason; Kasevich, Mark; Kavanagh, Bradley J.; von Klitzing, Wolf; Kovachy, Tim; Krikler, Benjamin; Krutzik, Markus; Lewicki, Marek; Lien, Yu-Hung; Liu, Miaoyuan; Luciano, Giuseppe Gaetano; Magnon, Alain; Mahmoud, Mohammed; Malik, Sarah; McCabe, Christopher; Mitchell, Jeremiah; Pahl, Julia; Pal, Debapriya; Pandey, Saurabh; Papazoglou, Dimitris; Paternostro, Mauro; Penning, Bjoern; Peters, Achim; Prevedelli, Marco; Puthiya-Veettil, Vishnupriya; Quenby, John; Rasel, Ernst; Ravenhall, Sean; Sfar, Haifa Rejeb; Ringwood, Jack; Roura, Albert; Sabulsky, Dylan; Sameed, Muhammed; Sauer, Ben; Schaffer, Stefan Alaric; Schiller, Stephan; Schkolnik, Vladimir; Schlippert, Dennis; Schubert, Christian; Shayeghi, Armin; Shipsey, Ian; Signorini, Carla; Soares-Santos, Marcelle; Sorrentino, Fiodor; Singh, Yajpal; Sumner, Timothy; Tassis, Konstantinos; Tentindo, Silvia; Tino, Guglielmo Maria; Tinsley, Jonathan N.; Unwin, James; Valenzuela, Tristan; Vasilakis, Georgios; Vaskonen, Ville; Vogt, Christian; Webber-Date, Alex; Wenzlawski, Andre; Windpassinger, Patrick; Woltmann, Marian; Holynski, Michael; Yazgan, Efe; Zhan, Ming-Sheng; Zou, Xinhao; Zupan, Jure
Comments: V2 -- added support authors
Submitted: 2019-08-02, last modified: 2019-10-10
We propose in this White Paper a concept for a space experiment using cold atoms to search for ultra-light dark matter, and to detect gravitational waves in the frequency range between the most sensitive ranges of LISA and the terrestrial LIGO/Virgo/KAGRA/INDIGO experiments. This interdisciplinary experiment, called Atomic Experiment for Dark Matter and Gravity Exploration (AEDGE), will also complement other planned searches for dark matter, and exploit synergies with other gravitational wave detectors. We give examples of the extended range of sensitivity to ultra-light dark matter offered by AEDGE, and how its gravitational-wave measurements could explore the assembly of super-massive black holes, first-order phase transitions in the early universe and cosmic strings. AEDGE will be based upon technologies now being developed for terrestrial experiments using cold atoms, and will benefit from the space experience obtained with, e.g., LISA and cold atom experiments in microgravity. This paper is based on a submission (v1) in response to the Call for White Papers for the Voyage 2050 long-term plan in the ESA Science Programme. ESA limited the number of White Paper authors to 30. However, in this version (v2) we have welcomed as supporting authors participants in the Workshop on Atomic Experiments for Dark Matter and Gravity Exploration held at CERN: ({\tt https://indico.cern.ch/event/830432/}), as well as other interested scientists, and have incorporated additional material.
[8]  oai:arXiv.org:1905.02765  [pdf] - 1972676
Micrometeoroid Events in LISA Pathfinder
Comments: 22 pages, 14 figures, accepted in ApJ
Submitted: 2019-05-07, last modified: 2019-10-02
The zodiacal dust complex, a population of dust and small particles that pervades the Solar System, provides important insight into the formation and dynamics of planets, comets, asteroids, and other bodies. Here we present a new set of data obtained using a novel technique: direct measurements of momentum transfer to a spacecraft from individual particle impacts. This technique is made possible by the extreme precision of the instruments flown on the LISA Pathfinder spacecraft, a technology demonstrator for a future space-based gravitational wave observatory that operated near the first Sun-Earth Lagrange point from early 2016 through Summer of 2017. Using a simple model of the impacts and knowledge of the control system, we show that it is possible to detect impacts and measure properties such as the transferred momentum (related to the particle's mass and velocity), direction of travel, and location of impact on the spacecraft. In this paper, we present the results of a systematic search for impacts during 4348 hours of Pathfinder data. We report a total of 54 candidates with momenta ranging from 0.2$\,\mu\textrm{Ns}$ to 230$\,\mu\textrm{Ns}$. We furthermore make a comparison of these candidates with models of micrometeoroid populations in the inner solar system including those resulting from Jupiter-family comets, Oort-cloud comets, Hailey-type comets, and Asteroids. We find that our measured population is consistent with a population dominated by Jupiter-family comets with some evidence for a smaller contribution from Hailey-type comets. This is in agreement with consensus models of the zodiacal dust complex in the momentum range sampled by LISA Pathfinder.
[9]  oai:arXiv.org:1909.10598  [pdf] - 2017716
Space test of the Equivalence Principle: first results of the MICROSCOPE mission
Comments: To appear in CQG
Submitted: 2019-09-23
The Weak Equivalence Principle (WEP), stating that two bodies of different compositions and/or mass fall at the same rate in a gravitational field (universality of free fall), is at the very foundation of General Relativity. The MICROSCOPE mission aims to test its validity to a precision of $10^{-15}$, two orders of magnitude better than current on-ground tests, by using two masses of different compositions (titanium and platinum alloys) on a quasi-circular trajectory around the Earth. This is realised by measuring the accelerations inferred from the forces required to maintain the two masses exactly in the same orbit. Any significant difference between the measured accelerations, occurring at a defined frequency, would correspond to the detection of a violation of the WEP, or to the discovery of a tiny new type of force added to gravity. MICROSCOPE's first results show no hint for such a difference, expressed in terms of E\"otv\"os parameter $\delta(Ti,Pt)=[-1\pm{}9{\rm (stat)}\pm{}9{\rm (syst)}] \times{}10^{-15}$ (both 1$\sigma$ uncertainties) for a titanium and platinum pair of materials. This result was obtained on a session with 120 orbital revolutions representing 7\% of the current available data acquired during the whole mission. The quadratic combination of 1$\sigma$ uncertainties leads to a current limit on $\delta$ of about $1.3\times{}10^{-14}$.
[10]  oai:arXiv.org:1909.00834  [pdf] - 1960371
The local dark sector. Probing gravitation's low-acceleration frontier and dark matter in the Solar System neighborhood
Comments: White Paper submitted to ESA's Voyage 2050 call for papers. Reference updated
Submitted: 2019-09-02, last modified: 2019-09-11
We speculate on the development and availability of new innovative propulsion techniques in the 2040s, that will allow us to fly a spacecraft outside the Solar System (at 150 AU and more) in a reasonable amount of time, in order to directly probe our (gravitational) Solar System neighborhood and answer pressing questions regarding the dark sector (dark energy and dark matter). We identify two closely related main science goals, as well as secondary objectives that could be fulfilled by a mission dedicated to probing the local dark sector: (i) begin the exploration of gravitation's low-acceleration regime with a man-made spacecraft and (ii) improve our knowledge of the local dark matter and baryon densities. Those questions can be answered by directly measuring the gravitational potential with an atomic clock on-board a spacecraft on an outbound Solar System orbit, and by comparing the spacecraft's trajectory with that predicted by General Relativity through the combination of ranging data and the in-situ measurement (and correction) of non-gravitational accelerations with an on-board accelerometer. Despite a wealth of new experiments getting online in the near future, that will bring new knowledge about the dark sector, it is very unlikely that those science questions will be closed in the next two decades. More importantly, it is likely that it will be even more urgent than currently to answer them. Tracking a spacecraft carrying a clock and an accelerometer as it leaves the Solar System may well be the easiest and fastest way to directly probe our dark environment.
[11]  oai:arXiv.org:1908.11584  [pdf] - 1967032
LISA Pathfinder Performance Confirmed in an Open-Loop Configuration: Results from the Free-Fall Actuation Mode
Comments:
Submitted: 2019-08-30
We report on the results of the LISA Pathfinder (LPF) free-fall mode experiment, in which the control force needed to compensate the quasistatic differential force acting on two test masses is applied intermittently as a series of "impulse" forces lasting a few seconds and separated by roughly 350 s periods of true free fall. This represents an alternative to the normal LPF mode of operation in which this balancing force is applied continuously, with the advantage that the acceleration noise during free fall is measured in the absence of the actuation force, thus eliminating associated noise and force calibration errors. The differential acceleration noise measurement presented here with the free-fall mode agrees with noise measured with the continuous actuation scheme, representing an important and independent confirmation of the LPF result. An additional measurement with larger actuation forces also shows that the technique can be used to eliminate actuation noise when this is a dominant factor.
[12]  oai:arXiv.org:1903.12372  [pdf] - 1916847
Improved Measurements of the \b{eta}-Decay Response of Liquid Xenon with the LUX Detector
Comments:
Submitted: 2019-03-29, last modified: 2019-06-07
We report results from an extensive set of measurements of the \b{eta}-decay response in liquid xenon.These measurements are derived from high-statistics calibration data from injected sources of both $^{3}$H and $^{14}$C in the LUX detector. The mean light-to-charge ratio is reported for 13 electric field values ranging from 43 to 491 V/cm, and for energies ranging from 1.5 to 145 keV.
[13]  oai:arXiv.org:1905.09060  [pdf] - 1887968
Temperature stability in the sub-milliHertz band with LISA Pathfinder
Comments: 13 pages, 16 figures. MNRAS LaTeX style file version 3.0
Submitted: 2019-05-22
LISA Pathfinder (LPF) was a technology pioneering mission designed to test key technologies required for gravitational wave detection in space. In the low frequency regime (milli-Hertz and below), where space-based gravitational wave observatories will operate, temperature fluctuations play a crucial role since they can couple into the interferometric measurement and the test masses' free-fall accuracy in many ways. A dedicated temperature measurement subsystem, with noise levels in 10$\,\mu$K$\,$Hz$^{-1/2}$ down to $1\,$mHz was part of the diagnostics unit on board LPF. In this paper we report on the temperature measurements throughout mission operations, characterize the thermal environment, estimate transfer functions between different locations and report temperature stability (and its time evolution) at frequencies as low as 10$\,\mu$Hz, where typically values around $1\,$K$\,$Hz$^{-1/2}$ were measured.
[14]  oai:arXiv.org:1904.04694  [pdf] - 1864169
Forbush decreases and $<$ 2-day GCR flux non-recurrent variations studied with LISA Pathfinder
Comments:
Submitted: 2019-04-09
Non-recurrent short term variations of the galactic cosmic-ray (GCR) flux above 70 MeV n$^{-1}$ were observed between 2016 February 18 and 2017 July 3 aboard the European Space Agency LISA Pathfinder (LPF) mission orbiting around the Lagrange point L1 at 1.5$\times$10$^6$ km from Earth. The energy dependence of three Forbush decreases (FDs) is studied and reported here. A comparison of these observations with others carried out in space down to the energy of a few tens of MeV n$^{-1}$ shows that the same GCR flux parameterization applies to events of different intensity during the main phase. FD observations in L1 with LPF and geomagnetic storm occurrence is also presented. Finally, the characteristics of GCR flux non-recurrent variations (peaks and depressions) of duration $<$ 2 days and their association with interplanetary structures are investigated. It is found that, most likely, plasma compression regions between subsequent corotating high-speed streams cause peaks, while heliospheric current sheet crossing cause the majority of the depressions.
[15]  oai:arXiv.org:1903.08924  [pdf] - 1853681
LISA Pathfinder
Comments: Preprint of an article submitted for consideration in Lepton-Photon 2017 conference proceedings \copyright 2019 copyright World Scientific Publishing Company
Submitted: 2019-03-21
Since the 2017 Nobel Prize in Physics was awarded for the observation of gravitational waves, it is fair to say that the epoch of gravitational wave astronomy (GWs) has begun. However, a number of interesting sources of GWs can only be observed from space. To demonstrate the feasibility of the Laser Interferometer Space Antenna (LISA), a future gravitational wave observatory in space, the LISA Pathfinder satellite was launched on December, 3rd 2015. Measurements of the spurious forces accelerating an otherwise free-falling test mass, and detailed investigations of the individual subsystems needed to achieve the free-fall, have been conducted throughout the mission. This overview article starts with the purpose and aim of the mission, explains satellite hardware and mission operations and ends with a summary of selected important results and an outlook towards LISA. From the LISA Pathfinder experience, we can conclude that the proposed LISA mission is feasible.
[16]  oai:arXiv.org:1812.05491  [pdf] - 1871447
LISA Pathfinder Platform Stability and Drag-free Performance
Comments: 16 pages, 10 figures
Submitted: 2018-12-13
The science operations of the LISA Pathfinder mission has demonstrated the feasibility of sub-femto-g free-fall of macroscopic test masses necessary to build a LISA-like gravitational wave observatory in space. While the main focus of interest, i.e. the optical axis or the $x$-axis, has been extensively studied, it is also of interest to evaluate the stability of the spacecraft with respect to all the other degrees of freedom. The current paper is dedicated to such a study, with a focus set on an exhaustive and quantitative evaluation of the imperfections and dynamical effects that impact the stability with respect to its local geodesic. A model of the complete closed-loop system provides a comprehensive understanding of each part of the in-loop coordinates spectra. As will be presented, this model gives very good agreements with LISA Pathfinder flight data. It allows one to identify the physical noise source at the origin and the physical phenomena underlying the couplings. From this, the performances of the stability of the spacecraft, with respect to its geodesic, are extracted as a function of frequency. Close to $1 mHz$, the stability of the spacecraft on the $X_{SC}$, $Y_{SC}$ and $Z_{SC}$ degrees of freedom is shown to be of the order of $5.0\ 10^{-15} m\ s^{-2}/\sqrt{Hz}$ for X and $4.0 \ 10^{-14} m\ s^{-2}/\sqrt{Hz}$ for Y and Z. For the angular degrees of freedom, the values are of the order $3\ 10^{-12} rad\ s^{-2}/\sqrt{Hz}$ for $\Theta_{SC}$ and $3\ 10^{-13} rad\ s^{-2}/\sqrt{Hz}$ for $H_{SC}$ and $\Phi_{SC}$.
[17]  oai:arXiv.org:1809.08969  [pdf] - 1789523
Experimental results from the ST7 mission on LISA Pathfinder
Anderson, G; Anderson, J; Anderson, M; Aveni, G; Bame, D; Barela, P; Blackman, K; Carmain, A; Chen, L; Cherng, M; Clark, S; Connally, M; Connolly, W; Conroy, D; Cooper, M; Cutler, C; D'Agostino, J; Demmons, N; Dorantes, E; Dunn, C; Duran, M; Ehrbar, E; Evans, J; Fernandez, J; Franklin, G; Girard, M; Gorelik, J; Hruby, V; Hsu, O; Jackson, D; Javidnia, S; Kern, D; Knopp, M; Kolasinski, R; Kuo, C; Le, T; Li, I; Liepack, O; Littlefield, A; Maghami, P; Malik, S; Markley, L; Martin, R; Marrese-Reading, C; Mehta, J; Mennela, J; Miller, D; Nguyen, D; O'Donnell, J; Parikh, R; Plett, G; Ramsey, T; Randolph, T; Rhodes, S; Romero-Wolf, A; Roy, T; Ruiz, A; Shaw, H; Slutsky, J; Spence, D; Stocky, J; Tallon, J; Thorpe, I; Tolman, W; Umfress, H; Valencia, R; Valerio, C; Warner, W; Wellman, J; Willis, P; Ziemer, J; Zwahlen, J; Armano, M; Audley, H; Baird, J; Binetruy, P; Born, a M; Bortoluzzi, D; Castelli, E; Cavalleri, A; Cesarini, A; Cruise, A M; Danzmann, K; Silva, M de Deus; Diepholz, I; Dixon, G; Dolesi, R; Ferraioli, L; Ferroni, V; Fitzsimons, E D; Freschi, M; Gesa, L; Gibert, F; Giardini, D; Giusteri, R; Grimani, C; Grzymisch, J; Harrison, I; Heinzel, G; Hewitson, M; Hollington, D; Hoyland, D; Hueller, M; Inchauspe, H; Jennrich, O; Jetzer, P; Karnesis, N; Kaune, B; Korsakova, N; Killow, C J; Lobo, J A; Lloro, I; Liu, L; Lopez-Zaragoza, J P; Maarschalkerweerd, R; Mance, D; Meshksar, N; Martin, V; Martin-Polo, L; Martino, J; Martin-Porqueras, F; Mateos, I; McNamara, P W; Mendes, J; Mendes, L; Nofrarias, M; Paczkowski, S; Perreur-Lloyd, M; Petiteau, A; Pivato, P; Plagnol, E; Ramos-Castro, J; Reiche, J; Robertson, D I; Rivas, F; Russano, G; Sopuerta, C F; Sumner, T; Texier, D; Vetrugno, D; Vitale, S; Wanner, G; Ward, H; Wass, P J; Weber, W J; Wissel, L; Wittchen, A; Zweifel, P
Comments:
Submitted: 2018-09-24, last modified: 2018-10-16
The Space Technology 7 Disturbance Reduction System (ST7-DRS) is a NASA technology demonstration payload that operated from January 2016 through July of 2017 on the European Space Agency's LISA Pathfinder spacecraft. The joint goal of the NASA and ESA missions was to validate key technologies for a future space-based gravitational wave observatory targeting the source-rich milliHertz band. The two primary components of ST7-DRS are a micropropulsion system based on colloidal micro-Newton thrusters (CMNTs) and a control system that simultaneously controls the attitude and position of the spacecraft and the two free-flying test masses (TMs). This paper presents our main experimental results and summarizes the overall the performance of the CMNTs and control laws. We find that the CMNT performance to be consistent with pre-flight predictions, with a measured system thrust noise on the order of $100\,\textrm{nN}/\sqrt{\textrm{Hz}}$ in the $1\,\textrm{mHz}\leq f \leq 30\,\textrm{mHz}$ band. The control system maintained the TM-spacecraft separation with an RMS error of less than 2$\,$nm and a noise spectral density of less than $3\,\textrm{nm}/\sqrt{\textrm{Hz}}$ in the same band. Thruster calibration measurements yield thrust values consistent with the performance model and ground-based thrust-stand measurements, to within a few percent. We also report a differential acceleration noise between the two test masses with a spectral density of roughly $3\,\textrm{fm}/\textrm{s}^2/\sqrt{\textrm{Hz}}$ in the $1\,\textrm{mHz}\leq f \leq 30\,\textrm{mHz}$ band, slightly less than twice as large as the best performance reported with the baseline LISA Pathfinder configuration and below the current requirements for the Laser Interferometer Space Antenna (LISA) mission.
[18]  oai:arXiv.org:1807.07113  [pdf] - 1758152
Search for annual and diurnal rate modulations in the LUX experiment
Comments: 12 pages, 9 figures
Submitted: 2018-07-18, last modified: 2018-09-27
Various dark matter models predict annual and diurnal modulations of dark matter interaction rates in Earth-based experiments as a result of the Earth's motion in the halo. Observation of such features can provide generic evidence for detection of dark matter interactions. This paper reports a search for both annual and diurnal rate modulations in the LUX dark matter experiment using over 20 calendar months of data acquired between 2013 and 2016. This search focuses on electron recoil events at low energies, where leptophilic dark matter interactions are expected to occur and where the DAMA experiment has observed a strong rate modulation for over two decades. By using the innermost volume of the LUX detector and developing robust cuts and corrections, we obtained a stable event rate of 2.3$\pm$0.2~cpd/keV$_{\text{ee}}$/tonne, which is among the lowest in all dark matter experiments. No statistically significant annual modulation was observed in energy windows up to 26~keV$_{\text{ee}}$. Between 2 and 6~keV$_{\text{ee}}$, this analysis demonstrates the most sensitive annual modulation search up to date, with 9.2$\sigma$ tension with the DAMA/LIBRA result. We also report no observation of diurnal modulations above 0.2~cpd/keV$_{\text{ee}}$/tonne amplitude between 2 and 6~keV$_{\text{ee}}$.
[19]  oai:arXiv.org:1806.08581  [pdf] - 1703884
Calibrating the system dynamics of LISA Pathfinder
Comments:
Submitted: 2018-06-22
LISA Pathfinder (LPF) was a European Space Agency mission with the aim to test key technologies for future space-borne gravitational-wave observatories like LISA. The main scientific goal of LPF was to demonstrate measurements of differential acceleration between free-falling test masses at the sub-femto-g level, and to understand the residual acceleration in terms of a physical model of stray forces, and displacement readout noise. A key step toward reaching the LPF goals was the correct calibration of the dynamics of LPF, which was a three-body system composed by two test-masses enclosed in a single spacecraft, and subject to control laws for system stability. In this work, we report on the calibration procedures adopted to calculate the residual differential stray force per unit mass acting on the two test-masses in their nominal positions. The physical parameters of the adopted dynamical model are presented, together with their role on LPF performance. The analysis and results of these experiments show that the dynamics of the system was accurately modeled and the dynamical parameters were stationary throughout the mission. Finally, the impact and importance of calibrating system dynamics for future space-based gravitational wave observatories is discussed.
[20]  oai:arXiv.org:1802.09374  [pdf] - 1673077
Characteristics and energy dependence of recurrent galactic cosmic-ray flux depressions and of a Forbush decrease with LISA Pathfinder
Comments:
Submitted: 2018-02-23, last modified: 2018-04-27
Galactic cosmic-ray (GCR) energy spectra observed in the inner heliosphere are modulated by the solar activity, the solar polarity and structures of solar and interplanetary origin. A high counting rate particle detector (PD) aboard LISA Pathfinder (LPF), meant for subsystems diagnostics, was devoted to the measurement of galactic cosmic-ray and solar energetic particle integral fluxes above 70 MeV n$^{-1}$ up to 6500 counts s$^{-1}$. PD data were gathered with a sampling time of 15 s. Characteristics and energy-dependence of GCR flux recurrent depressions and of a Forbush decrease dated August 2, 2016 are reported here. The capability of interplanetary missions, carrying PDs for instrument performance purposes, in monitoring the passage of interplanetary coronal mass ejections (ICMEs) is also discussed.
[21]  oai:arXiv.org:1711.07427  [pdf] - 1634200
Measuring the Galactic Cosmic Ray Flux with the LISA Pathfinder Radiation Monitor
Comments:
Submitted: 2017-11-20, last modified: 2018-01-12
Test mass charging caused by cosmic rays will be a significant source of acceleration noise for space-based gravitational wave detectors like LISA. Operating between December 2015 and July 2017, the technology demonstration mission LISA Pathfinder included a bespoke monitor to help characterise the relationship between test mass charging and the local radiation environment. The radiation monitor made in situ measurements of the cosmic ray flux while also providing information about its energy spectrum. We describe the monitor and present measurements which show a gradual 40% increase in count rate coinciding with the declining phase of the solar cycle. Modulations of up to 10% were also observed with periods of 13 and 26 days that are associated with co-rotating interaction regions and heliospheric current sheet crossings. These variations in the flux above the monitor detection threshold (approximately 70 MeV) are shown to be coherent with measurements made by the IREM monitor on-board the Earth orbiting INTEGRAL spacecraft. Finally we use the measured deposited energy spectra, in combination with a GEANT4 model, to estimate the galactic cosmic ray differential energy spectrum over the course of the mission.
[22]  oai:arXiv.org:1712.01176  [pdf] - 1878642
The MICROSCOPE mission: first results of a space test of the Equivalence Principle
Comments: Typos corrected
Submitted: 2017-12-04, last modified: 2017-12-06
According to the Weak Equivalence Principle, all bodies should fall at the same rate in a gravitational field. The MICROSCOPE satellite, launched in April 2016, aims to test its validity at the $10^{-15}$ precision level, by measuring the force required to maintain two test masses (of titanium and platinum alloys) exactly in the same orbit. A non-vanishing result would correspond to a violation of the Equivalence Principle, or to the discovery of a new long-range force. Analysis of the first data gives $\delta\rm{(Ti,Pt)}= [-1 \pm 9 (\mathrm{stat}) \pm 9 (\mathrm{syst})] \times 10^{-15}$ (1$\sigma$ statistical uncertainty) for the titanium-platinum E\"otv\"os parameter characterizing the relative difference in their free-fall accelerations.
[23]  oai:arXiv.org:1709.00800  [pdf] - 1611913
Ultra-Low Energy Calibration of LUX Detector using $^{127}$Xe Electron Capture
Comments: 10 pages, 10 figures, 2 tables
Submitted: 2017-09-03
We report an absolute calibration of the ionization yields($\textit{Q$_y$})$ and fluctuations for electronic recoil events in liquid xenon at discrete energies between 186 eV and 33.2 keV. The average electric field applied across the liquid xenon target is 180 V/cm. The data are obtained using low energy $^{127}$Xe electron capture decay events from the 95.0-day first run from LUX (WS2013) in search of Weakly Interacting Massive Particles (WIMPs). The sequence of gamma-ray and X-ray cascades associated with $^{127}$I de-excitations produces clearly identified 2-vertex events in the LUX detector. We observe the K- (binding energy, 33.2 keV), L- (5.2 keV), M- (1.1 keV), and N- (186 eV) shell cascade events and verify that the relative ratio of observed events for each shell agrees with calculations. The N-shell cascade analysis includes single extracted electron (SE) events and represents the lowest-energy electronic recoil $\textit{in situ}$ measurements that have been explored in liquid xenon.
[24]  oai:arXiv.org:1704.02297  [pdf] - 1582421
First Searches for Axions and Axion-Like Particles with the LUX Experiment
Comments:
Submitted: 2017-04-07, last modified: 2017-06-30
The first searches for axions and axion-like particles with the Large Underground Xenon (LUX) experiment are presented. Under the assumption of an axio-electric interaction in xenon, the coupling constant between axions and electrons, gAe is tested, using data collected in 2013 with an exposure totalling 95 live-days $\times$ 118 kg. A double-sided, profile likelihood ratio statistic test excludes gAe larger than 3.5 $\times$ 10$^{-12}$ (90% C.L.) for solar axions. Assuming the DFSZ theoretical description, the upper limit in coupling corresponds to an upper limit on axion mass of 0.12 eV/c$^{2}$, while for the KSVZ description masses above 36.6 eV/c$^{2}$ are excluded. For galactic axion-like particles, values of gAe larger than 4.2 $\times$ 10$^{-13}$ are excluded for particle masses in the range 1-16 keV/c$^{2}$. These are the most stringent constraints to date for these interactions.
[25]  oai:arXiv.org:1705.03380  [pdf] - 1583256
Limits on spin-dependent WIMP-nucleon cross section obtained from the complete LUX exposure
Comments: 7 pages, 3 figures, version accepted by PRL
Submitted: 2017-05-09, last modified: 2017-06-23
We present experimental constraints on the spin-dependent WIMP-nucleon elastic cross sections from the total 129.5 kg-year exposure acquired by the Large Underground Xenon experiment (LUX), operating at the Sanford Underground Research Facility in Lead, South Dakota (USA). A profile likelihood ratio analysis allows 90% CL upper limits to be set on the WIMP-neutron (WIMP-proton) cross section of $\sigma_n$ = 1.6$\times 10^{-41}$ cm$^{2}$ ($\sigma_p$ = 5$\times 10^{-40}$ cm$^{2}$) at 35 GeV$c^{-2}$, almost a sixfold improvement over the previous LUX spin-dependent results. The spin-dependent WIMP-neutron limit is the most sensitive constraint to date.
[26]  oai:arXiv.org:1703.09144  [pdf] - 1554108
LUX-ZEPLIN (LZ) Technical Design Report
Mount, B. J.; Hans, S.; Rosero, R.; Yeh, M.; Chan, C.; Gaitskell, R. J.; Huang, D. Q.; Makkinje, J.; Malling, D. C.; Pangilinan, M.; Rhyne, C. A.; Taylor, W. C.; Verbus, J. R.; Kim, Y. D.; Lee, H. S.; Lee, J.; Leonard, D. S.; Li, J.; Belle, J.; Cottle, A.; Lippincott, W. H.; Markley, D. J.; Martin, T. J.; Sarychev, M.; Tope, T. E.; Utes, M.; Wang, R.; Young, I.; Araújo, H. M.; Bailey, A. J.; Bauer, D.; Colling, D.; Currie, A.; Fayer, S.; Froborg, F.; Greenwood, S.; Jones, W. G.; Kasey, V.; Khaleeq, M.; Olcina, I.; Paredes, B. López; Richards, A.; Sumner, T. J.; Tomás, A.; Vacheret, A.; Brás, P.; Lindote, A.; Lopes, M. I.; Neves, F.; Rodrigues, J. P.; Silva, C.; Solovov, V. N.; Barry, M. J.; Cole, A.; Dobi, A.; Edwards, W. R.; Faham, C. H.; Fiorucci, S.; Gantos, N. J.; Gehman, V. M.; Gilchriese, M. G. D.; Hanzel, K.; Hoff, M. D.; Kamdin, K.; Lesko, K. T.; McConnell, C. T.; O'Sullivan, K.; Oliver-Mallory, K. C.; Patton, S. J.; Saba, J. S.; Sorensen, P.; Thomas, K. J.; Tull, C. E.; Waldron, W. L.; Witherell, M. S.; Bernstein, A.; Kazkaz, K.; Xu, J.; Akimov, D. Yu.; Bolozdynya, A. I.; Khromov, A. V.; Konovalov, A. M.; Kumpan, A. V.; Sosnovtsev, V. V.; Dahl, C. E.; Temples, D.; Carmona-Benitez, M. C.; de Viveiros, L.; Akerib, D. S.; Auyeung, H.; Biesiadzinski, T. P.; Breidenbach, M.; Bramante, R.; Conley, R.; Craddock, W. W.; Fan, A.; Hau, A.; Ignarra, C. M.; Ji, W.; Krebs, H. J.; Linehan, R.; Lee, C.; Luitz, S.; Mizrachi, E.; Monzani, M. E.; O'Neill, F. G.; Pierson, S.; Racine, M.; Ratcliff, B. N.; Shutt, G. W.; Shutt, T. A.; Skarpaas, K.; Stifter, K.; To, W. H.; Va'vra, J.; Whitis, T. J.; Wisniewski, W. J.; Bai, X.; Bunker, R.; Coughlen, R.; Hjemfelt, C.; Leonard, R.; Miller, E. H.; Morrison, E.; Reichenbacher, J.; Schnee, R. W.; Stark, M. R.; Sundarnath, K.; Tiedt, D. R.; Timalsina, M.; Bauer, P.; Carlson, B.; Horn, M.; Johnson, M.; Keefner, J.; Maupin, C.; Taylor, D. J.; Balashov, S.; Ford, P.; Francis, V.; Holtom, E.; Khazov, A.; Kaboth, A.; Majewski, P.; Nikkel, J. A.; O'Dell, J.; Preece, R. M.; van der Grinten, M. G. D.; Worm, S. D.; Mannino, R. L.; Stiegler, T. M.; Terman, P. A.; Webb, R. C.; Levy, C.; Mock, J.; Szydagis, M.; Busenitz, J. K.; Elnimr, M.; Hor, J. Y-K.; Meng, Y.; Piepke, A.; Stancu, I.; Kreczko, L.; Krikler, B.; Penning, B.; Bernard, E. P.; Jacobsen, R. G.; McKinsey, D. N.; Watson, R.; Cutter, J. E.; El-Jurf, S.; Gerhard, R. M.; Hemer, D.; Hillbrand, S.; Holbrook, B.; Lenardo, B. G.; Manalaysay, A. G.; Morad, J. A.; Stephenson, S.; Thomson, J. A.; Tripathi, M.; Uvarov, S.; Haselschwardt, S. J.; Kyre, S.; Nehrkorn, C.; Nelson, H. N.; Solmaz, M.; White, D. T.; Cascella, M.; Dobson, J. E. Y.; Ghag, C.; Liu, X.; Manenti, L.; Reichhart, L.; Shaw, S.; Utku, U.; Beltrame, P.; Davison, T. J. R.; Marzioni, M. F.; Murphy, A. St. J.; Nilima, A.; Boxer, B.; Burdin, S.; Greenall, A.; Powell, S.; Rose, H. J.; Sutcliffe, P.; Balajthy, J.; Edberg, T. K.; Hall, C. R.; Silk, J. S.; Hertel, S.; Akerlof, C. W.; Arthurs, M.; Lorenzon, W.; Pushkin, K.; Schubnell, M.; Boast, K. E.; Carels, C.; Fruth, T.; Kraus, H.; Liao, F. -T.; Lin, J.; Scovell, P. R.; Druszkiewicz, E.; Khaitan, D.; Koyuncu, M.; Skulski, W.; Wolfs, F. L. H.; Yin, J.; Korolkova, E. V.; Kudryavtsev, V. A.; Rossiter, P.; Woodward, D.; Chiller, A. A.; Chiller, C.; Mei, D. -M.; Wang, L.; Wei, W. -Z.; While, M.; Zhang, C.; Alsum, S. K.; Benson, T.; Carlsmith, D. L.; Cherwinka, J. J.; Dasu, S.; Gregerson, G.; Gomber, B.; Pagac, A.; Palladino, K. J.; Vuosalo, C. O.; Xiao, Q.; Buckley, J. H.; Bugaev, V. V.; Olevitch, M. A.; Boulton, E. M.; Emmet, W. T.; Hurteau, T. W.; Larsen, N. A.; Pease, E. K.; Tennyson, B. P.; Tvrznikova, L.
Comments: 392 pages. Submitted to the Department of Energy as part of the documentation for the Critical Decision Numbers Two and Three (CD-2 and CD-3) management processes. Report also available by chapter at <a href="http://hep.ucsb.edu/LZ/TDR/">this URL</a>
Submitted: 2017-03-27
In this Technical Design Report (TDR) we describe the LZ detector to be built at the Sanford Underground Research Facility (SURF). The LZ dark matter experiment is designed to achieve sensitivity to a WIMP-nucleon spin-independent cross section of three times ten to the negative forty-eighth square centimeters.
[27]  oai:arXiv.org:1702.00786  [pdf] - 1537441
Laser Interferometer Space Antenna
Comments: Submitted to ESA on January 13th in response to the call for missions for the L3 slot in the Cosmic Vision Programme
Submitted: 2017-02-02, last modified: 2017-02-23
Following the selection of The Gravitational Universe by ESA, and the successful flight of LISA Pathfinder, the LISA Consortium now proposes a 4 year mission in response to ESA's call for missions for L3. The observatory will be based on three arms with six active laser links, between three identical spacecraft in a triangular formation separated by 2.5 million km. LISA is an all-sky monitor and will offer a wide view of a dynamic cosmos using Gravitational Waves as new and unique messengers to unveil The Gravitational Universe. It provides the closest ever view of the infant Universe at TeV energy scales, has known sources in the form of verification binaries in the Milky Way, and can probe the entire Universe, from its smallest scales near the horizons of black holes, all the way to cosmological scales. The LISA mission will scan the entire sky as it follows behind the Earth in its orbit, obtaining both polarisations of the Gravitational Waves simultaneously, and will measure source parameters with astrophysically relevant sensitivity in a band from below $10^{-4}\,$Hz to above $10^{-1}\,$Hz.
[28]  oai:arXiv.org:1702.04633  [pdf] - 1571007
Charge-induced force-noise on free-falling test masses: results from LISA Pathfinder
Comments: 9 Pages, 3 figures
Submitted: 2017-02-15
We report on electrostatic measurements made on board the European Space Agency mission LISA Pathfinder. Detailed measurements of the charge-induced electrostatic forces exerted on free-falling test masses (TMs) inside the capacitive gravitational reference sensor are the first made in a relevant environment for a space-based gravitational wave detector. Employing a combination of charge control and electric-field compensation, we show that the level of charge-induced acceleration noise on a single TM can be maintained at a level close to 1.0 fm/s^2/sqrt(Hz) across the 0.1-100 mHz frequency band that is crucial to an observatory such as LISA. Using dedicated measurements that detect these effects in the differential acceleration between the two test masses, we resolve the stochastic nature of the TM charge build up due to interplanetary cosmic rays and the TM charge-to-force coupling through stray electric fields in the sensor. All our measurements are in good agreement with predictions based on a relatively simple electrostatic model of the LISA Pathfinder instrument.
[29]  oai:arXiv.org:1608.07648  [pdf] - 1531370
Results from a search for dark matter in the complete LUX exposure
Comments: This version includes a combined analysis with previously published LUX results, and matches the version published in PRL
Submitted: 2016-08-26, last modified: 2017-01-13
We report constraints on spin-independent weakly interacting massive particle (WIMP)-nucleon scattering using a 3.35e4 kg-day exposure of the Large Underground Xenon (LUX) experiment. A dual-phase xenon time projection chamber with 250 kg of active mass is operated at the Sanford Underground Research Facility under Lead, South Dakota (USA). With roughly fourfold improvement in sensitivity for high WIMP masses relative to our previous results, this search yields no evidence of WIMP nuclear recoils. At a WIMP mass of 50 GeV/c^2, WIMP-nucleon spin-independent cross sections above 2.2e-46 cm^2 are excluded at the 90% confidence level. When combined with the previously reported LUX exposure, this exclusion strengthens to 1.1e-46 cm^2 at 50 GeV/c^2.
[30]  oai:arXiv.org:1608.05381  [pdf] - 1503451
Low-energy (0.7-74 keV) nuclear recoil calibration of the LUX dark matter experiment using D-D neutron scattering kinematics
LUX Collaboration; Akerib, D. S.; Alsum, S.; Araújo, H. M.; Bai, X.; Bailey, A. J.; Balajthy, J.; Beltrame, P.; Bernard, E. P.; Bernstein, A.; Biesiadzinski, T. P.; Boulton, E. M.; Bradley, A.; Bramante, R.; Brás, P.; Byram, D.; Cahn, S. B.; Carmona-Benitez, M. C.; Chan, C.; Chapman, J. J.; Chiller, A. A.; Chiller, C.; Currie, A.; Cutter, J. E.; Davison, T. J. R.; de Viveiros, L.; Dobi, A.; Dobson, J. E. Y.; Druszkiewicz, E.; Edwards, B. N.; Faham, C. H.; Fiorucci, S.; Gaitskell, R. J.; Gehman, V. M.; Ghag, C.; Gibson, K. R.; Gilchriese, M. G. D.; Hall, C. R.; Hanhardt, M.; Haselschwardt, S. J.; Hertel, S. A.; Hogan, D. P.; Horn, M.; Huang, D. Q.; Ignarra, C. M.; Ihm, M.; Jacobsen, R. G.; Ji, W.; Kamdin, K.; Kazkaz, K.; Khaitan, D.; Knoche, R.; Larsen, N. A.; Lee, C.; Lenardo, B. G.; Lesko, K. T.; Lindote, A.; Lopes, M. I.; Malling, D. C.; Manalaysay, A.; Mannino, R. L.; Marzioni, M. F.; McKinsey, D. N.; Mei, D. M.; Mock, J.; Moongweluwan, M.; Morad, J. A.; Murphy, A. St. J.; Nehrkorn, C.; Nelson, H. N.; Neves, F.; O'Sullivan, K.; Oliver-Mallory, K. C.; Palladino, K. J.; Pangilinan, M.; Pease, E. K.; Phelps, P.; Reichhart, L.; Rhyne, C. A.; Shaw, S.; Shutt, T. A.; Silva, C.; Solmaz, M.; Solovov, V. N.; Sorensen, P.; Stephenson, S.; Sumner, T. J.; Szydagis, M.; Taylor, D. J.; Taylor, W. C.; Tennyson, B. P.; Terman, P. A.; Tiedt, D. R.; To, W. H.; Tripathi, M.; Tvrznikova, L.; Uvarov, S.; Verbus, J. R.; Webb, R. C.; White, J. T.; Whitis, T. J.; Witherell, M. S.; Wolfs, F. L. H.; Xu, J.; Yazdani, K.; Young, S. K.; Zhang, C.
Comments: 24 pages, 15 figures, 6 tables
Submitted: 2016-08-18, last modified: 2016-10-26
The Large Underground Xenon (LUX) experiment is a dual-phase liquid xenon time projection chamber (TPC) operating at the Sanford Underground Research Facility in Lead, South Dakota. A calibration of nuclear recoils in liquid xenon was performed $\textit{in situ}$ in the LUX detector using a collimated beam of mono-energetic 2.45 MeV neutrons produced by a deuterium-deuterium (D-D) fusion source. The nuclear recoil energy from the first neutron scatter in the TPC was reconstructed using the measured scattering angle defined by double-scatter neutron events within the active xenon volume. We measured the absolute charge ($Q_{y}$) and light ($L_{y}$) yields at an average electric field of 180 V/cm for nuclear recoil energies spanning 0.7 to 74 keV and 1.1 to 74 keV, respectively. This calibration of the nuclear recoil signal yields will permit the further refinement of liquid xenon nuclear recoil signal models and, importantly for dark matter searches, clearly demonstrates measured ionization and scintillation signals in this medium at recoil energies down to $\mathcal{O}$(1 keV).
[31]  oai:arXiv.org:1512.03506  [pdf] - 1406496
Improved Limits on Scattering of Weakly Interacting Massive Particles from Reanalysis of 2013 LUX data
Comments: Accepted by Phys. Rev. Lett
Submitted: 2015-12-10, last modified: 2016-05-16
We present constraints on weakly interacting massive particles (WIMP)-nucleus scattering from the 2013 data of the Large Underground Xenon dark matter experiment, including $1.4\times10^{4}\;\mathrm{kg\; day}$ of search exposure. This new analysis incorporates several advances: single-photon calibration at the scintillation wavelength, improved event-reconstruction algorithms, a revised background model including events originating on the detector walls in an enlarged fiducial volume, and new calibrations from decays of an injected tritium $\beta$ source and from kinematically constrained nuclear recoils down to 1.1 keV. Sensitivity, especially to low-mass WIMPs, is enhanced compared to our previous results which modeled the signal only above a 3 keV minimum energy. Under standard dark matter halo assumptions and in the mass range above 4 $\mathrm{GeV}\,c^{-2}$, these new results give the most stringent direct limits on the spin-independent WIMP-nucleon cross section. The 90% C.L. upper limit has a minimum of 0.6 zb at 33 $\mathrm{GeV}\,c^{-2}$ WIMP mass.
[32]  oai:arXiv.org:1512.03133  [pdf] - 1402511
Tritium calibration of the LUX dark matter experiment
Comments:
Submitted: 2015-12-09, last modified: 2016-05-05
We present measurements of the electron-recoil (ER) response of the LUX dark matter detector based upon 170,000 highly pure and spatially-uniform tritium decays. We reconstruct the tritium energy spectrum using the combined energy model and find good agreement with expectations. We report the average charge and light yields of ER events in liquid xenon at 180 V/cm and 105 V/cm and compare the results to the NEST model. We also measure the mean charge recombination fraction and its fluctuations, and we investigate the location and width of the LUX ER band. These results provide input to a re-analysis of the LUX Run3 WIMP search.
[33]  oai:arXiv.org:1509.02910  [pdf] - 1286987
LUX-ZEPLIN (LZ) Conceptual Design Report
The LZ Collaboration; Akerib, D. S.; Akerlof, C. W.; Akimov, D. Yu.; Alsum, S. K.; Araújo, H. M.; Bai, X.; Bailey, A. J.; Balajthy, J.; Balashov, S.; Barry, M. J.; Bauer, P.; Beltrame, P.; Bernard, E. P.; Bernstein, A.; Biesiadzinski, T. P.; Boast, K. E.; Bolozdynya, A. I.; Boulton, E. M.; Bramante, R.; Buckley, J. H.; Bugaev, V. V.; Bunker, R.; Burdin, S.; Busenitz, J. K.; Carels, C.; Carlsmith, D. L.; Carlson, B.; Carmona-Benitez, M. C.; Cascella, M.; Chan, C.; Cherwinka, J. J.; Chiller, A. A.; Chiller, C.; Craddock, W. W.; Currie, A.; Cutter, J. E.; da Cunha, J. P.; Dahl, C. E.; Dasu, S.; Davison, T. J. R.; de Viveiros, L.; Dobi, A.; Dobson, J. E. Y.; Druszkiewicz, E.; Edberg, T. K.; Edwards, B. N.; Edwards, W. R.; Elnimr, M. M.; Emmet, W. T.; Faham, C. H.; Fiorucci, S.; Ford, P.; Francis, V. B.; Fu, C.; Gaitskell, R. J.; Gantos, N. J.; Gehman, V. M.; Gerhard, R. M.; Ghag, C.; Gilchriese, M. G. D.; Gomber, B.; Hall, C. R.; Harris, A.; Haselschwardt, S. J.; Hertel, S. A.; Hoff, M. D.; Holbrook, B.; Holtom, E.; Huang, D. Q.; Hurteau, T. W.; Ignarra, C. M.; Jacobsen, R. G.; Ji, W.; Ji, X.; Johnson, M.; Ju, Y.; Kamdin, K.; Kazkaz, K.; Khaitan, D.; Khazov, A.; Khromov, A. V.; Konovalov, A. M.; Korolkova, E. V.; Kraus, H.; Krebs, H. J.; Kudryavtsev, V. A.; Kumpan, A. V.; Kyre, S.; Larsen, N. A.; Lee, C.; Lenardo, B. G.; Lesko, K. T.; Liao, F. -T.; Lin, J.; Lindote, A.; Lippincott, W. H.; Liu, J.; Liu, X.; Lopes, M. I.; Lorenzon, W.; Luitz, S.; Majewski, P.; Malling, D. C.; Manalaysay, A. G.; Manenti, L.; Mannino, R. L.; Markley, D. J.; Martin, T. J.; Marzioni, M. F.; McKinsey, D. N.; Mei, D. -M.; Meng, Y.; Miller, E. H.; Mock, J.; Monzani, M. E.; Morad, J. A.; Murphy, A. St. J.; Nelson, H. N.; Neves, F.; Nikkel, J. A.; O'Neill, F. G.; O'Dell, J.; O'Sullivan, K.; Olevitch, M. A.; Oliver-Mallory, K. C.; Palladino, K. J.; Pangilinan, M.; Patton, S. J.; Pease, E. K.; Piepke, A.; Powell, S.; Preece, R. M.; Pushkin, K.; Ratcliff, B. N.; Reichenbacher, J.; Reichhart, L.; Rhyne, C.; Rodrigues, J. P.; Rose, H. J.; Rosero, R.; Saba, J. S.; Sarychev, M.; Schnee, R. W.; Schubnell, M. S. G.; Scovell, P. R.; Shaw, S.; Shutt, T. A.; Silva, C.; Skarpaas, K.; Skulski, W.; Solovov, V. N.; Sorensen, P.; Sosnovtsev, V. V.; Stancu, I.; Stark, M. R.; Stephenson, S.; Stiegler, T. M.; Sumner, T. J.; Sundarnath, K.; Szydagis, M.; Taylor, D. J.; Taylor, W.; Tennyson, B. P.; Terman, P. A.; Thomas, K. J.; Thomson, J. A.; Tiedt, D. R.; To, W. H.; Tomás, A.; Tripathi, M.; Tull, C. E.; Tvrznikova, L.; Uvarov, S.; Va'vra, J.; van der Grinten, M. G. D.; Verbus, J. R.; Vuosalo, C. O.; Waldron, W. L.; Wang, L.; Webb, R. C.; Wei, W. -Z.; While, M.; White, D. T.; Whitis, T. J.; Wisniewski, W. J.; Witherell, M. S.; Wolfs, F. L. H.; Woods, E.; Woodward, D.; Worm, S. D.; Yeh, M.; Yin, J.; Young, S. K.; Zhang, C.
Comments: 278 pages. Submitted to the Department of Energy as part of the documentation for the Critical Decision Number One (CD-1) management process. Report also available by chapter at http://hep.ucsb.edu/LZ/CDR. This version includes corrections of minor typographic errors
Submitted: 2015-09-09, last modified: 2015-09-23
The design and performance of the LUX-ZEPLIN (LZ) detector is described as of March 2015 in this Conceptual Design Report. LZ is a second-generation dark-matter detector with the potential for unprecedented sensitivity to weakly interacting massive particles (WIMPs) of masses from a few GeV/c2 to hundreds of TeV/c2. With total liquid xenon mass of about 10 tonnes, LZ will be the most sensitive experiment for WIMPs in this mass region by the end of the decade. This report describes in detail the design of the LZ technical systems. Expected backgrounds are quantified and the performance of the experiment is presented. The LZ detector will be located at the Sanford Underground Research Facility in South Dakota. The organization of the LZ Project and a summary of the expected cost and current schedule are given.
[34]  oai:arXiv.org:1508.00812  [pdf] - 1323444
Characterising and Testing Deep UV LEDs for Use in Space Applications
Comments:
Submitted: 2015-08-04
Deep ultraviolet (DUV) light sources are used to neutralise isolated test masses in highly sensitive space-based gravitational experiments. An example is the LISA Pathfinder charge management system, which uses low-pressure mercury lamps. A future gravitational-wave observatory such as eLISA will use UV light-emitting diodes (UV LEDs), which offer numerous advantages over traditional discharge lamps. Such devices have limited space heritage but are are now available from a number of commercial suppliers. Here we report on a test campaign that was carried out to quantify the general properties of three types of commercially available UV LEDs and demonstrate their suitability for use in space. Testing included general electrical and UV output measurements, spectral stability, pulsed performance, temperature dependence as well as thermal vacuum, radiation and vibration survivability.
[35]  oai:arXiv.org:1412.8384  [pdf] - 1154814
Free-flight experiments in LISA Pathfinder
Comments: 13 pages, 5 figures. Accepted to Journal Of Physics, Conference Series. Presented at 10th International LISA Symposium, May 2014, Gainesville, FL, USA
Submitted: 2014-12-29
The LISA Pathfinder mission will demonstrate the technology of drag-free test masses for use as inertial references in future space-based gravitational wave detectors. To accomplish this, the Pathfinder spacecraft will perform drag-free flight about a test mass while measuring the acceleration of this primary test mass relative to a second reference test mass. Because the reference test mass is contained within the same spacecraft, it is necessary to apply forces on it to maintain its position and attitude relative to the spacecraft. These forces are a potential source of acceleration noise in the LISA Pathfinder system that are not present in the full LISA configuration. While LISA Pathfinder has been designed to meet it's primary mission requirements in the presence of this noise, recent estimates suggest that the on-orbit performance may be limited by this `suspension noise'. The drift-mode or free-flight experiments provide an opportunity to mitigate this noise source and further characterize the underlying disturbances that are of interest to the designers of LISA-like instruments. This article provides a high-level overview of these experiments and the methods under development to analyze the resulting data.
[36]  oai:arXiv.org:1403.1299  [pdf] - 862558
Radiogenic and Muon-Induced Backgrounds in the LUX Dark Matter Detector
Comments: 18 pages, 12 figures / 17 images, submitted to Astropart. Phys
Submitted: 2014-03-05
The Large Underground Xenon (LUX) dark matter experiment aims to detect rare low-energy interactions from Weakly Interacting Massive Particles (WIMPs). The radiogenic backgrounds in the LUX detector have been measured and compared with Monte Carlo simulation. Measurements of LUX high-energy data have provided direct constraints on all background sources contributing to the background model. The expected background rate from the background model for the 85.3 day WIMP search run is $(2.6\pm0.2_{\textrm{stat}}\pm0.4_{\textrm{sys}})\times10^{-3}$~events~keV$_{ee}^{-1}$~kg$^{-1}$~day$^{-1}$ in a 118~kg fiducial volume. The observed background rate is $(3.6\pm0.4_{\textrm{stat}})\times10^{-3}$~events~keV$_{ee}^{-1}$~kg$^{-1}$~day$^{-1}$, consistent with model projections. The expectation for the radiogenic background in a subsequent one-year run is presented.
[37]  oai:arXiv.org:1402.3731  [pdf] - 788195
A Detailed Look at the First Results from the Large Underground Xenon (LUX) Dark Matter Experiment
Comments: 16 pages, 3 figures, to appear in the proceedings of The 10th International Symposium on Cosmology and Particle Astrophysics (CosPA2013); fixed author list and added info on new calibration
Submitted: 2014-02-15, last modified: 2014-02-25
LUX, the world's largest dual-phase xenon time-projection chamber, with a fiducial target mass of 118 kg and 10,091 kg-days of exposure thus far, is currently the most sensitive direct dark matter search experiment. The initial null-result limit on the spin-independent WIMP-nucleon scattering cross-section was released in October 2013, with a primary scintillation threshold of 2 phe, roughly 3 keVnr for LUX. The detector has been deployed at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, and is the first experiment to achieve a limit on the WIMP cross-section lower than $10^{-45}$ cm$^{2}$. Here we present a more in-depth discussion of the novel energy scale employed to better understand the nuclear recoil light and charge yields, and of the calibration sources, including the new internal tritium source. We found the LUX data to be in conflict with low-mass WIMP signal interpretations of other results.
[38]  oai:arXiv.org:1310.8214  [pdf] - 795009
First results from the LUX dark matter experiment at the Sanford Underground Research Facility
Comments: Accepted by Phys. Rev. Lett. Appendix A included as supplementary material with PRL article
Submitted: 2013-10-30, last modified: 2014-02-05
The Large Underground Xenon (LUX) experiment, a dual-phase xenon time-projection chamber operating at the Sanford Underground Research Facility (Lead, South Dakota), was cooled and filled in February 2013. We report results of the first WIMP search dataset, taken during the period April to August 2013, presenting the analysis of 85.3 live-days of data with a fiducial volume of 118 kg. A profile-likelihood analysis technique shows our data to be consistent with the background-only hypothesis, allowing 90% confidence limits to be set on spin-independent WIMP-nucleon elastic scattering with a minimum upper limit on the cross section of $7.6 \times 10^{-46}$ cm$^{2}$ at a WIMP mass of 33 GeV/c$^2$. We find that the LUX data are in strong disagreement with low-mass WIMP signal interpretations of the results from several recent direct detection experiments.
[39]  oai:arXiv.org:1306.4487  [pdf] - 683437
State space modelling and data analysis exercises in LISA Pathfinder
Comments: Plenary talk presented at the 9th International LISA Symposium, 21-25 May 2012, Paris
Submitted: 2013-06-19, last modified: 2013-06-21
LISA Pathfinder is a mission planned by the European Space Agency to test the key technologies that will allow the detection of gravitational waves in space. The instrument on-board, the LISA Technology package, will undergo an exhaustive campaign of calibrations and noise characterisation campaigns in order to fully describe the noise model. Data analysis plays an important role in the mission and for that reason the data analysis team has been developing a toolbox which contains all the functionalities required during operations. In this contribution we give an overview of recent activities, focusing on the improvements in the modelling of the instrument and in the data analysis campaigns performed both with real and simulated data.
[40]  oai:arXiv.org:1305.5720  [pdf] - 667680
The Gravitational Universe
Consortium, The eLISA; :; Seoane, P. Amaro; Aoudia, S.; Audley, H.; Auger, G.; Babak, S.; Baker, J.; Barausse, E.; Barke, S.; Bassan, M.; Beckmann, V.; Benacquista, M.; Bender, P. L.; Berti, E.; Binétruy, P.; Bogenstahl, J.; Bonvin, C.; Bortoluzzi, D.; Brause, N. C.; Brossard, J.; Buchman, S.; Bykov, I.; Camp, J.; Caprini, C.; Cavalleri, A.; Cerdonio, M.; Ciani, G.; Colpi, M.; Congedo, G.; Conklin, J.; Cornish, N.; Danzmann, K.; de Vine, G.; DeBra, D.; Freitag, M. Dewi; Di Fiore, L.; Aguilo, M. Diaz; Diepholz, I.; Dolesi, R.; Dotti, M.; Barranco, G. Fernández; Ferraioli, L.; Ferroni, V.; Finetti, N.; Fitzsimons, E.; Gair, J.; Galeazzi, F.; Garcia, A.; Gerberding, O.; Gesa, L.; Giardini, D.; Gibert, F.; Grimani, C.; Groot, P.; Cervantes, F. Guzman; Haiman, Z.; Halloin, H.; Heinzel, G.; Hewitson, M.; Hogan, C.; Holz, D.; Hornstrup, A.; Hoyland, D.; Hoyle, C. D.; Hueller, M.; Hughes, S.; Jetzer, P.; Kalogera, V.; Karnesis, N.; Kilic, M.; Killow, C.; Klipstein, W.; Kochkina, E.; Korsakova, N.; Krolak, A.; Larson, S.; Lieser, M.; Littenberg, T.; Livas, J.; Lloro, I.; Mance, D.; Madau, P.; Maghami, P.; Mahrdt, C.; Marsh, T.; Mateos, I.; Mayer, L.; McClelland, D.; McKenzie, K.; McWilliams, S.; Merkowitz, S.; Miller, C.; Mitryk, S.; Moerschell, J.; Mohanty, S.; Monsky, A.; Mueller, G.; Müller, V.; Nelemans, G.; Nicolodi, D.; Nissanke, S.; Nofrarias, M.; Numata, K.; Ohme, F.; Otto, M.; Perreur-Lloyd, M.; Petiteau, A.; Phinney, E. S.; Plagnol, E.; Pollack, S.; Porter, E.; Prat, P.; Preston, A.; Prince, T.; Reiche, J.; Richstone, D.; Robertson, D.; Rossi, E. M.; Rosswog, S.; Rubbo, L.; Ruiter, A.; Sanjuan, J.; Sathyaprakash, B. S.; Schlamminger, S.; Schutz, B.; Schütze, D.; Sesana, A.; Shaddock, D.; Shah, S.; Sheard, B.; Sopuerta, C. F.; Spector, A.; Spero, R.; Stanga, R.; Stebbins, R.; Stede, G.; Steier, F.; Sumner, T.; Sun, K. -X.; Sutton, A.; Tanaka, T.; Tanner, D.; Thorpe, I.; Tröbs, M.; Tinto, M.; Tu, H. -B.; Vallisneri, M.; Vetrugno, D.; Vitale, S.; Volonteri, M.; Wand, V.; Wang, Y.; Wanner, G.; Ward, H.; Ware, B.; Wass, P.; Weber, W. J.; Yu, Y.; Yunes, N.; Zweifel, P.
Comments: 20 pages; submitted to the European Space Agency on May 24th, 2013 for the L2/L3 selection of ESA's Cosmic Vision program
Submitted: 2013-05-24
The last century has seen enormous progress in our understanding of the Universe. We know the life cycles of stars, the structure of galaxies, the remnants of the big bang, and have a general understanding of how the Universe evolved. We have come remarkably far using electromagnetic radiation as our tool for observing the Universe. However, gravity is the engine behind many of the processes in the Universe, and much of its action is dark. Opening a gravitational window on the Universe will let us go further than any alternative. Gravity has its own messenger: Gravitational waves, ripples in the fabric of spacetime. They travel essentially undisturbed and let us peer deep into the formation of the first seed black holes, exploring redshifts as large as z ~ 20, prior to the epoch of cosmic re-ionisation. Exquisite and unprecedented measurements of black hole masses and spins will make it possible to trace the history of black holes across all stages of galaxy evolution, and at the same time constrain any deviation from the Kerr metric of General Relativity. eLISA will be the first ever mission to study the entire Universe with gravitational waves. eLISA is an all-sky monitor and will offer a wide view of a dynamic cosmos using gravitational waves as new and unique messengers to unveil The Gravitational Universe. It provides the closest ever view of the early processes at TeV energies, has guaranteed sources in the form of verification binaries in the Milky Way, and can probe the entire Universe, from its smallest scales around singularities and black holes, all the way to cosmological dimensions.
[41]  oai:arXiv.org:1112.1481  [pdf] - 1092209
Position Reconstruction in a Dual Phase Xenon Scintillation Detector
Comments: 8 pages, 7 figures, in the Conference Record of IEEE NSS 2011, accepted for publication in IEEE Trans. on Nuc. Sci
Submitted: 2011-12-07, last modified: 2012-09-26
We studied the application of statistical reconstruction algorithms, namely maximum likelihood and least squares methods, to the problem of event reconstruction in a dual phase liquid xenon detector. An iterative method was developed for in-situ reconstruction of the PMT light response functions from calibration data taken with an uncollimated gamma-ray source. Using the techniques described, the performance of the ZEPLIN-III dark matter detector was studied for 122 keV gamma-rays. For the inner part of the detector (R<100 mm), spatial resolutions of 13 mm and 1.6 mm FWHM were measured in the horizontal plane for primary and secondary scintillation, respectively. An energy resolution of 8.1% FWHM was achieved at that energy. The possibility of using this technique for improving performance and reducing cost of scintillation cameras for medical applications is currently under study.
[42]  oai:arXiv.org:1202.0839  [pdf] - 968251
Low-frequency gravitational-wave science with eLISA/NGO
Comments: 20 pages, 8 figures, proceedings of the 9th Amaldi Conference on Gravitational Waves. Final journal version. For a longer exposition of the eLISA science case, see http://arxiv.org/abs/1201.3621
Submitted: 2012-02-03, last modified: 2012-09-12
We review the expected science performance of the New Gravitational-Wave Observatory (NGO, a.k.a. eLISA), a mission under study by the European Space Agency for launch in the early 2020s. eLISA will survey the low-frequency gravitational-wave sky (from 0.1 mHz to 1 Hz), detecting and characterizing a broad variety of systems and events throughout the Universe, including the coalescences of massive black holes brought together by galaxy mergers; the inspirals of stellar-mass black holes and compact stars into central galactic black holes; several millions of ultracompact binaries, both detached and mass transferring, in the Galaxy; and possibly unforeseen sources such as the relic gravitational-wave radiation from the early Universe. eLISA's high signal-to-noise measurements will provide new insight into the structure and history of the Universe, and they will test general relativity in its strong-field dynamical regime.
[43]  oai:arXiv.org:1202.3595  [pdf] - 478148
Detecting Cosmic Gravitational-wave Background from Super-heavy Cosmic Strings with LISA
Comments: 10 pages, 7 figures
Submitted: 2012-02-16
Although cosmic string scenario for galaxy formation is disfavored by CMB data, it is of great interest in the generation of cosmic gravitational-wave background. This research aims to develop an algorithm to extract cosmic gravitational-wave background produced by cosmic strings from the LISA data stream, and apply the algorithm to the simulated data stream containing the background produced by cosmic strings with various strength to study the detection threshold for this source. For 1-yr observation, It is found that the detection threshold of G{\mu} is 3.12 \times 10^-16 in the standard scenario. In the case that p and {\epsilon} are adjustable, the detectable region in parameter space is defined by (G{\mu})^2/3 {\epsilon}^-1/3 / p> 4.6 \times 10-11.
[44]  oai:arXiv.org:1202.2976  [pdf] - 476308
Removing the trend of drift induced from acceleration noise for LISA
Comments: 12 pages, 6 figures
Submitted: 2012-02-14
In this paper we demonstrate a methodology to remove the power of the drift induced from random acceleration on LISA proof mass in the frequency domain. The drift must be cleaned from LISA time series data in advance of any further analysis. The cleaning is usually performed in the time domain by using a quadratic function to fit the time series data, and then removing the fitted part from the data. Having Fourier transformed the residuals, and then convolved with LISA transfer function, LISA sensitivity curve can be obtained. However, cosmic gravitational-wave background cannot be retrieved with this approach due to its random nature. Here we provide a new representation of power spectrum given by discrete Fourier transform, which is applied to find the function of the drift power for the cleaning in the frequency domain. We also give the probability distribution used to analyze the data in the frequency domain. We combine several techniques, including Markov Chain Monte Carlo method, simulated annealing, and Gelman & Rubin's method, with Baye's theorem to build the algorithm. The algorithm is utilized to analyze 24 simulations of LISA instrumental noise. We prove that the LISA sensitivity can be recovered through this approach. It can help us to build algorithms for some tasks which are must accomplished in the frequency domain for LISA data analysis. This method can be applied to other space-borne interferometers if charges on their proof masses cannot be perfectly cancelled.
[45]  oai:arXiv.org:1201.3621  [pdf] - 465838
eLISA: Astrophysics and cosmology in the millihertz regime
Comments: Submitted to GW Notes; abstract abridged due to arXiv requirements
Submitted: 2012-01-17
This document introduces the exciting and fundamentally new science and astronomy that the European New Gravitational Wave Observatory (NGO) mission (derived from the previous LISA proposal) will deliver. The mission (which we will refer to by its informal name "eLISA") will survey for the first time the low-frequency gravitational wave band (about 0.1 mHz to 1 Hz), with sufficient sensitivity to detect interesting individual astrophysical sources out to z = 15. The eLISA mission will discover and study a variety of cosmic events and systems with high sensitivity: coalescences of massive black holes binaries, brought together by galaxy mergers; mergers of earlier, less-massive black holes during the epoch of hierarchical galaxy and black-hole growth; stellar-mass black holes and compact stars in orbits just skimming the horizons of massive black holes in galactic nuclei of the present era; extremely compact white dwarf binaries in our Galaxy, a rich source of information about binary evolution and about future Type Ia supernovae; and possibly most interesting of all, the uncertain and unpredicted sources, for example relics of inflation and of the symmetry-breaking epoch directly after the Big Bang. eLISA's measurements will allow detailed studies of these signals with high signal-to-noise ratio, addressing most of the key scientific questions raised by ESA's Cosmic Vision programme in the areas of astrophysics and cosmology. They will also provide stringent tests of general relativity in the strong-field dynamical regime, which cannot be probed in any other way. This document not only describes the science but also gives an overview on the mission design and orbits.
[46]  oai:arXiv.org:1110.4769  [pdf] - 1085051
WIMP-nucleon cross-section results from the second science run of ZEPLIN-III
Comments:
Submitted: 2011-10-21, last modified: 2011-12-16
We report experimental upper limits on WIMP-nucleon elastic scattering cross sections from the second science run of ZEPLIN-III at the Boulby Underground Laboratory. A raw fiducial exposure of 1,344 kg.days was accrued over 319 days of continuous operation between June 2010 and May 2011. A total of eight events was observed in the signal acceptance region in the nuclear recoil energy range 7-29 keV, which is compatible with background expectations. This allows the exclusion of the scalar cross-section above 4.8E-8 pb near 50 GeV/c^2 WIMP mass with 90% confidence. Combined with data from the first run, this result improves to 3.9E-8 pb. The corresponding WIMP-neutron spin-dependent cross-section limit is 8.0E-3 pb. The ZEPLIN programme reaches thus its conclusion at Boulby, having deployed and exploited successfully three liquid xenon experiments of increasing reach.
[47]  oai:arXiv.org:1111.2248  [pdf] - 1091528
Quenching Factor for Low Energy Nuclear Recoils in a Plastic Scintillator
Comments: 8 pages, 9 figures
Submitted: 2011-11-09
Plastic scintillators are widely used in industry, medicine and scientific research, including nuclear and particle physics. Although one of their most common applications is in neutron detection, experimental data on their response to low-energy nuclear recoils are scarce. Here, the relative scintillation efficiency for neutron-induced nuclear recoils in a polystyrene-based plastic scintillator (UPS-923A) is presented, exploring recoil energies between 125 keV and 850 keV. Monte Carlo simulations, incorporating light collection efficiency and energy resolution effects, are used to generate neutron scattering spectra which are matched to observed distributions of scintillation signals to parameterise the energy-dependent quenching factor. At energies above 300 keV the dependence is reasonably described using the semi-empirical formulation of Birks and a kB factor of (0.014+/-0.002) g/MeVcm^2 has been determined. Below that energy the measured quenching factor falls more steeply than predicted by the Birks formalism.
[48]  oai:arXiv.org:1110.0103  [pdf] - 967104
After LUX: The LZ Program
Comments: Conference proceedings from APS DPF 2011. 9 pages, 6 figures
Submitted: 2011-10-01, last modified: 2011-10-13
The LZ program consists of two stages of direct dark matter searches using liquid Xe detectors. The first stage will be a 1.5-3 tonne detector, while the last stage will be a 20 tonne detector. Both devices will benefit tremendously from research and development performed for the LUX experiment, a 350 kg liquid Xe dark matter detector currently operating at the Sanford Underground Laboratory. In particular, the technology used for cryogenics and electrical feedthroughs, circulation and purification, low-background materials and shielding techniques, electronics, calibrations, and automated control and recovery systems are all directly scalable from LUX to the LZ detectors. Extensive searches for potential background sources have been performed, with an emphasis on previously undiscovered background sources that may have a significant impact on tonne-scale detectors. The LZ detectors will probe spin-independent interaction cross sections as low as 5E-49 cm2 for 100 GeV WIMPs, which represents the ultimate limit for dark matter detection with liquid xenon technology.
[49]  oai:arXiv.org:1106.0808  [pdf] - 1077078
ZE3RA: The ZEPLIN-III Reduction and Analysis Package
Comments:
Submitted: 2011-06-04
ZE3RA is the software package responsible for processing the raw data from the ZEPLIN-III dark matter experiment and its reduction into a set of parameters used in all subsequent analyses. The detector is a liquid xenon time projection chamber with scintillation and electroluminescence signals read out by an array of 31 photomultipliers. The dual range 62-channel data stream is optimised for the detection of scintillation pulses down to a single photoelectron and of ionisation signals as small as those produced by single electrons. We discuss in particular several strategies related to data filtering, pulse finding and pulse clustering which are tuned to recover the best electron/nuclear recoil discrimination near the detection threshold, where most dark matter elastic scattering signatures are expected. The software was designed assuming only minimal knowledge of the physics underlying the detection principle, allowing an unbiased analysis of the experimental results and easy extension to other detectors with similar requirements.
[50]  oai:arXiv.org:1103.0393  [pdf] - 385243
Performance of the veto detector incorporated into the ZEPLIN-III experiment
Comments:
Submitted: 2011-03-02, last modified: 2011-05-01
The ZEPLIN-III experiment is operating in its second phase at the Boulby Underground Laboratory in search of dark matter WIMPs. The major upgrades to the instrument over its first science run include lower background photomultiplier tubes and installation of a plastic scintillator veto system. Performance results from the veto detector using calibration and science data in its first six months of operation in coincidence with ZEPLIN-III are presented. With fully automated operation and calibration, the veto system has maintained high stability and achieves near unity live time relative to ZEPLIN-III. Calibrations with a neutron source demonstrate a rejection of 60% of neutron-induced nuclear recoils in ZEPLIN-III that might otherwise be misidentified as WIMPs. This tagging efficiency reduces the expected untagged nuclear recoil background from neutrons during science data taking to a very low rate of ~0.2 events per year in the WIMP acceptance region. Additionally, the veto detector provides rejection of 28% of gamma-ray induced background events, allowing the sampling of the dominant source of background in ZEPLIN-III - multiple scatter gamma-rays with rare topologies. Since WIMPs will not be tagged by the veto detector, and tags due to gamma-rays and neutrons are separable, this population of multiple scatter events may be characterised without biasing the analysis of candidate WIMP signals in the data.
[51]  oai:arXiv.org:1012.5968  [pdf] - 1042805
From laboratory experiments to LISA Pathfinder: achieving LISA geodesic motion
Comments: Proceedings of the 8th LISA Symposium. To appear Class. Quantum Grav. 28 (2011)
Submitted: 2010-12-29, last modified: 2011-01-20
This paper presents a quantitative assessment of the performance of the upcoming LISA Pathfinder geodesic explorer mission. The findings are based on the results of extensive ground testing and simulation campaigns using flight hardware and flight control and operations algorithms. The results show that, for the central experiment of measuring the stray differential acceleration between the LISA test masses, LISA Pathfinder will be able to verify the overall acceleration noise to within a factor two of the LISA requirement at 1 mHz and within a factor 6 at 0.1 mHz. We also discuss the key elements of the physical model of disturbances, coming from LISA Pathfinder and ground measurement, that will guarantee the LISA performance.
[52]  oai:arXiv.org:1004.4207  [pdf] - 325335
The ZEPLIN-III Anti-Coincidence Veto Detector
Comments:
Submitted: 2010-04-23, last modified: 2010-04-27
The design, optimisation and construction of an anti-coincidence veto detector to complement the ZEPLIN-III direct dark matter search instrument is described. One tonne of plastic scintillator is arranged into 52 bars individually read out by photomultipliers and coupled to a gadolinium-loaded passive polypropylene shield. Particular attention has been paid to radiological content. The overall aim has been to achieve a veto detector of low threshold and high efficiency without the creation of additional background in ZEPLIN-III, all at a reasonable cost. Extensive experimental measurements of the components have been made, including radioactivity levels and performance characteristics. These have been used to inform a complete end-to-end Monte Carlo simulation that has then been used to calculate the expected performance of the new instrument, both operating alone and as an anti-coincidence detector for ZEPLIN-III. The veto device will be capable of rejecting over 65% of coincident nuclear recoil events from neutron background in the energy range of interest in ZEPLIN-III. This will reduce the background in ZEPLIN-III from ~0.4 to ~0.14 events per year in the WIMP acceptance region, a significant factor in the event of a non-zero observation. Furthermore, in addition to providing valuable diagnostic capabilities, the veto is capable of tagging over 15% for gamma-ray rejection, all whilst contributing no significant additional background. In conjunction with the replacement of the internal ZEPLIN-III photomultiplier array, the new veto is expected to improve significantly the sensitivity of the ZEPLIN-III instrument to dark matter, allowing spin independent WIMP-nucleon cross sections below 1E-8 pb to be probed.
[53]  oai:arXiv.org:0909.5367  [pdf] - 657686
On the nature of the first galaxies selected at 350 microns
Comments: Accepted for publication in The Astrophysical Journal
Submitted: 2009-09-29
[abridged] We present constraints on the nature of the first galaxies selected at 350 microns. The sample includes galaxies discovered in the deepest blank-field survey at 350 microns (in the Bootes Deep Field) and also later serendipitous detections in the Lockman Hole. Spectral energy distribution templates are fit to identified counterparts, and the sample is found to comprise IR-luminous galaxies at 1<z<3 predominantly powered by star formation. The first spectrum of a 350-micron-selected galaxy provides an additional confirmation, showing prominent dust grain features typically associated with star-forming galaxies. Compared to submillimeter galaxies selected at 850 and 1100 microns, galaxies selected at 350 microns have a similar range of far-infrared color temperatures. However, no 350-micron-selected sources are reliably detected at 850 or 1100 microns. Galaxies in our sample with redshifts 1<z<2 show a tight correlation between the far- and mid-infrared flux densities, but galaxies at higher redshifts show a large dispersion in their mid- to far-infrared colors. The 350-micron flux densities (15<S(350)<40 mJy) place these objects near the Herschel/SPIRE 350-micron confusion threshold, with the lower limit on the star formation rate density suggesting the bulk of the 350-micron contribution will come from less luminous infrared sources and normal galaxies.
[54]  oai:arXiv.org:0812.1150  [pdf] - 19200
Results from the First Science Run of the ZEPLIN-III Dark Matter Search Experiment
Comments: 12 pages, 17 figures
Submitted: 2008-12-05, last modified: 2009-09-02
The ZEPLIN-III experiment in the Palmer Underground Laboratory at Boulby uses a 12kg two-phase xenon time projection chamber to search for the weakly interacting massive particles (WIMPs) that may account for the dark matter of our Galaxy. The detector measures both scintillation and ionisation produced by radiation interacting in the liquid to differentiate between the nuclear recoils expected from WIMPs and the electron recoil background signals down to ~10keV nuclear recoil energy. An analysis of 847kg.days of data acquired between February 27th 2008 and May 20th 2008 has excluded a WIMP-nucleon elastic scattering spin-independent cross-section above 8.1x10(-8)pb at 55GeV/c2 with a 90% confidence limit. It has also demonstrated that the two-phase xenon technique is capable of better discrimination between electron and nuclear recoils at low-energy than previously achieved by other xenon-based experiments.
[55]  oai:arXiv.org:0802.0582  [pdf] - 9771
Astrodynamical Space Test of Relativity using Optical Devices I (ASTROD I) - A class-M fundamental physics mission proposal for Cosmic Vision 2015-2025
Comments: 26 pages, 11 figures, shortened from the original cosmic vision proposal, submitted to Experimental Astronomy; this version, shortened to 25 pages, re-organized and added references, is accepted for publication in Experimental Astronomy
Submitted: 2008-02-05, last modified: 2008-12-12
ASTROD I is a planned interplanetary space mission with multiple goals. The primary aims are: to test General Relativity with an improvement in sensitivity of over 3 orders of magnitude, improving our understanding of gravity and aiding the development of a new quantum gravity theory; to measure key solar system parameters with increased accuracy, advancing solar physics and our knowledge of the solar system and to measure the time rate of change of the gravitational constant with an order of magnitude improvement and the anomalous Pioneer acceleration, thereby probing dark matter and dark energy gravitationally. It is an international project, with major contributions from Europe and China and is envisaged as the first in a series of ASTROD missions. ASTROD I will consist of one spacecraft carrying a telescope, four lasers, two event timers and a clock. Two-way, two-wavelength laser pulse ranging will be used between the spacecraft in a solar orbit and deep space laser stations on Earth, to achieve the ASTROD I goals. A second mission, ASTROD II is envisaged as a three-spacecraft mission which would test General Relativity to one part per billion, enable detection of solar g-modes, measure the solar Lense-Thirring effect to 10 parts per million, and probe gravitational waves at frequencies below the LISA bandwidth. In the third phase (ASTROD III or Super-ASTROD), larger orbits could be implemented to map the outer solar system and to probe primordial gravitational-waves at frequencies below the ASTROD II bandwidth.
[56]  oai:arXiv.org:0707.1930  [pdf] - 1000439
Improved Simulation of the Mass Charging for ASTROD I
Comments: 20 pages, 14 figures, submitted to International Journal of Modern Physics D
Submitted: 2007-07-13
The electrostatic charging of the test mass in ASTROD I (Astrodynamical Space Test of Relativity using Optical Devices I) mission can affect the quality of the science data as a result of spurious Coulomb and Lorentz forces. To estimate the size of the resultant disturbances, credible predictions of charging rates and the charging noise are required. Using the GEANT4 software toolkit, we present a detailed Monte Carlo simulation of the ASTROD I test mass charging due to exposure of the spacecraft to galactic cosmic-ray (GCR) protons and alpha particles (3He, 4He) in the space environment. A positive charging rate of 33.3 e+/s at solar minimum is obtained. This figure reduces by 50% at solar maximum. Based on this charging rate and factoring in the contribution of minor cosmic-ray components, we calculate the acceleration noise and stiffness associated with charging. We conclude that the acceleration noise arising from Coulomb and Lorentz effects are well below the ASTROD I acceleration noise limit at 0.1 mHz both at solar minimum and maximum. The coherent Fourier components due to charging are investigated, it needs to be studied carefully in order to ensure that these do not compromise the quality of science data in the ASTROD I mission.
[57]  oai:arXiv.org:0704.3303  [pdf] - 744
ASTROD I Charging Simulation and Disturbances
Comments: 17 pages, 11 figures, submitted to General Relativity and Gravitation
Submitted: 2007-04-24
ASTROD I is planned as a single spacecraft mission. It will use interferometric and pulse ranging techniques between the spacecraft and ground stations, to make high precision measurements of the parameters that describe the solar system, and to test relativistic gravity with improved accuracy. At the heart of the spacecraft is a test mass, which the spacecraft will follow using a drag-free control system. The mission critically depends on maintaining the geodesic motion of the test mass. Charging of the test mass due to cosmic rays and solar particles will disturb its geodesic motion. We have modelled the charging process using the GEANT4 toolkit and a simplified, geometrical model and estimate that the ASTROD I test mass will charge positively, at a rate of 24 +/-7 e+/s, due to cosmic ray protons and alpha particles (3He and 4He) at solar minimum. We have used the results of this simulation to estimate the magnitude of disturbances associated with test mass charging, for the worst-case scenario, taking into account uncertainties in the model and potential charging contributions from minor cosmic-ray components.
[58]  oai:arXiv.org:0704.2210  [pdf] - 497
First Constraints on Source Counts at 350 Microns
Comments: accepted for publication in The Astrophysical Journal
Submitted: 2007-04-17
We have imaged a $\sim$6 arcminute$^2$ region in the Bo\"otes Deep Field using the 350 $\mu$m-optimised second generation Submillimeter High Angular Resolution Camera (SHARC II), achieving a peak 1$\sigma$ sensitivity of $\sim$5 mJy. We detect three sources above 3$\sigma$, and determine a spurious source detection rate of 1.09 in our maps. In the absence of $5\sigma$ detections, we rely on deep 24 $\mu$m and 20 cm imaging to deduce which sources are most likely to be genuine, giving two real sources. From this we derive an integral source count of 0.84$^{+1.39}_{-0.61}$ sources arcmin$^{-2}$ at $S>13$ mJy, which is consistent with 350 $\mu$m source count models that have an IR-luminous galaxy population evolving with redshift. We use these constraints to consider the future for ground-based short-submillimetre surveys.
[59]  oai:arXiv.org:astro-ph/0701858  [pdf] - 88987
First limits on WIMP nuclear recoil signals in ZEPLIN-II: a two phase xenon detector for dark matter detection
Comments: 38 Pages, 16 Figures, (v2: corrected table 2 description)
Submitted: 2007-01-30, last modified: 2007-01-31
Results are presented from the first underground data run of ZEPLIN-II, a 31 kg two phase xenon detector developed to observe nuclear recoils from hypothetical weakly interacting massive dark matter particles. Discrimination between nuclear recoils and background electron recoils is afforded by recording both the scintillation and ionisation signals generated within the liquid xenon, with the ratio of these signals being different for the two classes of event. This ratio is calibrated for different incident species using an AmBe neutron source and Co-60 gamma-ray sources. From our first 31 live days of running ZEPLIN-II, the total exposure following the application of fiducial and stability cuts was 225 kgxdays. A background population of radon progeny events was observed in this run, arising from radon emission in the gas purification getters, due to radon daughter ion decays on the surfaces of the walls of the chamber. An acceptance window, defined by the neutron calibration data, of 50% nuclear recoil acceptance between 5 keVee and 20 keVee, had an observed count of 29 events, with a summed expectation of 28.6+/-4.3 gamma-ray and radon progeny induced background events. These figures provide a 90% c.l. upper limit to the number of nuclear recoils of 10.4 events in this acceptance window, which converts to a WIMP-nucleon spin-independent cross-section with a minimum of 6.6x10^-7 pb following the inclusion of an energy dependent, calibrated, efficiency. A second run is currently underway in which the radon progeny will be eliminated, thereby removing the background population, with a projected sensitivity of 2x10^-7 pb for similar exposures as the first run.
[60]  oai:arXiv.org:astro-ph/0701859  [pdf] - 88988
Reply to: Critical revision of the ZEPLIN-I sensitivity to WIMP interactions
Comments: 5 pages
Submitted: 2007-01-30
Recent objections (Phys.Lett. B 637, 156) to the published Zeplin I limit (Astropart. Phys 23, 444) are shown to arise from misunderstandings of the calibration data and procedure, and a misreading of the data in one of the referenced papers.
[61]  oai:arXiv.org:astro-ph/0605500  [pdf] - 82187
The ZEPLIN-III dark matter detector: instrument design, manufacture and commissioning
Comments: 25 pages, 19 figures. Submitted to Astropart. Phys. Some figures down sampled to reduce size
Submitted: 2006-05-19
We present details of the technical design and manufacture of the ZEPLIN-III dark matter experiment. ZEPLIN-III is a two-phase xenon detector which measures both the scintillation light and the ionisation charge generated in the liquid by interacting particles and radiation. The instrument design is driven by both the physics requirements and by the technology requirements surrounding the use of liquid xenon. These include considerations of key performance parameters, such as the efficiency of scintillation light collection, restrictions placed on the use of materials to control the inherent radioactivity levels, attainment of high vacuum levels and chemical contamination control. The successful solution has involved a number of novel design and manufacturing features which will be of specific use to future generations of direct dark matter search experiments as they struggle with similar and progressively more demanding requirements.
[62]  oai:arXiv.org:astro-ph/0603243  [pdf] - 80452
The ZEPLIN-III dark matter detector: performance study using an end-to-end simulation tool
Comments: Submitted to Astroparticle Physics
Submitted: 2006-03-09
We present results from a GEANT4-based Monte Carlo tool for end-to-end simulations of the ZEPLIN-III dark matter experiment. ZEPLIN-III is a two-phase detector which measures both the scintillation light and the ionisation charge generated in liquid xenon by interacting particles and radiation. The software models the instrument response to radioactive backgrounds and calibration sources, including the generation, ray-tracing and detection of the primary and secondary scintillations in liquid and gaseous xenon, and subsequent processing by data acquisition electronics. A flexible user interface allows easy modification of detector parameters at run time. Realistic datasets can be produced to help with data analysis, an example of which is the position reconstruction algorithm developed from simulated data. We present a range of simulation results confirming the original design sensitivity of a few times $10^{-8}$ pb to the WIMP-nucleon cross-section.
[63]  oai:arXiv.org:astro-ph/0508405  [pdf] - 75294
On the discovery of the first 350 micron-selected galaxy
Comments: Accepted for publication in ApJ
Submitted: 2005-08-18
We report the detection of a 3.6sigma 350micron-selected source in the Bootes Deep Field. The source, the first Short-wavelength Submillimeter-selected Galaxy (SSG 1), was discovered as part of a blank field extragalactic survey using the 350micron-optimised Submillimeter High Angular Resolution Camera (SHARC II) at the Caltech Submillimeter Observatory. With multiwavelength photometry from NOAO-NDWFS (R and I band), FLAMEX (J and K_s), Spitzer (IRAC and MIPS) and the Westerbork 1.4GHz Deep Survey (radio upper limit), we are able to constrain the photometric redshift using different methods, all of which suggest a redshift of close to 1. In the absence of long-wavelength submillimeter data we use SED templates to infer that this source is an ultraluminous infrared galaxy (ULIRG) with a dust temperature of 30+/-5 K, occupying a region of luminosity-temperature space shared by modarate redshift ISO-selected ULIRGs (rather than high redshift SCUBA-selected SMGs). SHARC II can thus select SMGs with moderately "warm'' dust that might be missed in submillimeter surveys at longer wavelengths.
[64]  oai:arXiv.org:astro-ph/0501646  [pdf] - 70758
Resolving IRAS 09111-1007 at 350 microns - a different path to ULIRG formation?
Comments: 6 pages, 4 figures. Accepted for publication in MNRAS Letters
Submitted: 2005-01-31
We have resolved the ultraluminous infrared galaxy (ULIRG), IRAS 09111-1007, with the new 350 micron-optimised Second Generation Submillimeter High Angular Resolution Camera (SHARC II) and present the first submillimetre fluxes and images for the system. IRAS 09111-1007 comprises two interacting luminous infrared galaxies (LIRGs) with a projected nuclear separation of 39 kpc. The Western galaxy is roughly four times more luminous in the submillimetre than its Eastern counterpart. It is an extremely bright LIRG with an AGN. The classification of the Eastern source is uncertain: it could be a Seyfert 2 galaxy or a LINER. We highlight IRAS 09111-1007 as a system that necessitates further study: a double AGN ULIRG whose molecular gas content differs from other widely separated pairs and whose ULIRG phase might not be explained by current multiple merger and/or final stage ULIRG scenarios.
[65]  oai:arXiv.org:astro-ph/0405522  [pdf] - 65042
Detailed Calculation of Test-Mass Charging in the LISA Mission
Comments: 31 pages, 18 figures, 4 tables. to be published in Astroparticle Physics. Changed due to error found in normalisation of the simulation results
Submitted: 2004-05-26, last modified: 2004-10-07
The electrostatic charging of the LISA test masses due to exposure of the spacecraft to energetic particles in the space environment has implications in the design and operation of the gravitational inertial sensors and can affect the quality of the science data. Robust predictions of charging rates and associated stochastic fluctuations are therefore required for the exposure scenarios expected throughout the mission. We report on detailed charging simulations with the Geant4 toolkit, using comprehensive geometry and physics models, for Galactic cosmic-ray protons and helium nuclei. These predict positive charging rates of 50 +e/s (elementary charges per second) for solar minimum conditions, decreasing by half at solar maximum, and current fluctuations of up to 30 +e/s/Hz^{1/2}. Charging from sporadic solar events involving energetic protons was also investigated. Using an event-size distribution model, we conclude that their impact on the LISA science data is manageable. Several physical processes hitherto unexplored as potential charging mechanisms have also been assessed. Significantly, the kinetic emission of very low-energy secondary electrons due to bombardment of the inertial sensors by primary cosmic rays and their secondaries can produce charging currents comparable with the Monte Carlo rates.
[66]  oai:arXiv.org:astro-ph/0208412  [pdf] - 51228
Near and mid-infrared colours of star-forming galaxies in ELAIS fields
Comments: 18 pages, 15 figures; accepted for publication in MNRAS
Submitted: 2002-08-22
We present J and K-band near-infrared photometry of a sample of mid-infrared sources detected by the Infrared Space Observatory (ISO) as part of the European Large Area ISO-Survey (ELAIS) and study their classification and star-forming properties. We have used the Preliminary ELAIS Catalogue for the 6.7 micron (LW2) and 15 micron (LW3) fluxes. All of the high-reliability LW2 sources and 80 per cent of the LW3 sources are identified in the near-IR survey reaching K = 17.5 mag. The near- to mid-IR flux ratios can effectively be used to separate stars from galaxies in mid-IR surveys. The stars detected in our survey region are used to derive a new accurate calibration for the ELAIS ISOCAM data in both the LW2 and LW3 filters. We show that near to mid-IR colour-colour diagrams can be used to further classify galaxies, as well as study star-formation. The ISOCAM ELAIS survey is found to mostly detect strongly star-forming late-type galaxies, possibly starburst powered galaxies, and it also picks out obscured AGN. The ELAIS galaxies yield an average mid-IR flux ratio LW2/LW3 = 0.67 +/- 0.27. We discuss this [6.7/15] ratio as a star formation tracer using ISO and IRAS data of a local comparison sample. We find that the [K/15] ratio is also agood indicator of activity level in galaxies and conclude that the drop in the [6.7/15] ratio seen in strongly star-forming galaxies is a result of both an increase of 15 mic emission and an apparent depletion of 6.7 mic emission. Near-IR data together with the mid-IR give the possibility to estimate the relative amount of interstellar matter in the galaxies.
[67]  oai:arXiv.org:hep-ex/0109013  [pdf] - 363345
Study and suppression of anomalous fast events in inorganic scintillators for dark matter searches
Comments: 14 pages, 6 figures
Submitted: 2001-09-12
The status of dark matter searches with inorganic scintillator detectors at Boulby mine is reviewed and the results of tests with a CsI(Tl) crystal are presented. The objectives of the latter experiment were to study anomalous fast events previously observed and to identify ways to remove this background. Clear indications were found that these events were due to surface contamination of crystals by alphas, probably from radon decay. A new array of unencapsulated NaI(Tl) crystals immersed either in liquid paraffin or pure nitrogen atmosphere is under construction at Boulby. Such an approach allows complete control of the surface of the crystals and the ability to remove any surface contamination. First data from the unencapsulated NaI(Tl) do not show the presence of anomalous fast events.
[68]  oai:arXiv.org:astro-ph/0010483  [pdf] - 38830
Starburst activity in a ROSAT Narrow Emission-Line Galaxy
Comments: 8 pages, 9 figures, MNRAS accepted
Submitted: 2000-10-24
We present multiwaveband photometric and optical spectropolarimetric observations of the R=15.9 narrow emission line galaxy R117_A which lies on the edge of the error circle of the ROSAT X-ray source R117 (from McHardy et al 1998). The overall spectral energy distribution of the galaxy is well modelled by a combination of a normal spiral galaxy and a moderate-strength burst of star formation. The far infra-red and radio emission is extended along the major axis of the galaxy, indicating an extended starburst. On positional grounds, the galaxy is a good candidate for the identification of R117 and the observed X-ray flux is very close to what would be expected from a starburst of the observed far infra-red and radio fluxes. Although an obscured high redshift QSO cannot be entirely ruled out as contributing some fraction of the X-ray flux, we find no candidates to K=20.8 within the X-ray errorbox and so conclude that R117_A is responsible for a large fraction, if not all, of the X-ray emission from R117. Searches for indicators of an obscured AGN in R117_A have so far proven negative; deep spectropolarimetric observations show no signs of broad lines to a limit of one per cent and, for the observed far infra-red and radio emission, we would expect a ten times greater X-ray flux if the overall emission were powered by an AGN. We therefore conclude that the X-ray emission from R117 is dominated by starburst emission from the galaxy R117_A.
[69]  oai:arXiv.org:astro-ph/0010025  [pdf] - 38373
The European Large Area ISO Survey IV: the preliminary 90 micron luminosity function
Comments: MNRAS in press. 8 pages. Uses BoxedEPS (included). For more information on the ELAIS project see http://athena.ph.ic.ac.uk:80/
Submitted: 2000-10-02
We present the luminosity function of 90um selected galaxies from the European Large Area ISO Survey (ELAIS), extending to z=0.3. Their luminosities are in the range 10^9 < h_65^-2 L/Lsun < 10^12, i.e. non-ultraluminous. From our sample of 37 reliably detected galaxies in the ELAIS S1 region from the Efstathiou et al. (2000) S_90 >= 100mJy database, we found optical, 15um or 1.4GHz identifications for 24 (65%). We have obtained 2dF and UK Schmidt FLAIR spectroscopy of 89% of IDs to rigid multivariate flux limits. We construct a luminosity function assuming (a) our spectroscopic subset is an unbiased sparse sample, and (b) there are no galaxies which would not be represented in our spectroscopic sample at {\it any} redshift. We argue that we can be confident of both assumptions. We find the luminosity function is well-described by the local 100um luminosity function of Rowan-Robinson, Helou & Walker (1987). {\it Assuming} this local normalisation, we derive luminosity evolution of (1+z)^{2.45\pm0.85} (95% confidence). We argue that star formation dominates the bolometric luminosities of these galaxies and we derive comoving star formation rates in broad agreement with the Flores et al. (1999) and Rowan-Robinson et al. (1997) mid-IR-based estimates.
[70]  oai:arXiv.org:astro-ph/0008065  [pdf] - 1943527
The European Large Area ISO Survey III: 90micron extragalactic source counts
Comments: 13 pages, accepted by MNRAS. For more details on the ELAIS project see http://athena.ph.ic.ac.uk/
Submitted: 2000-08-03
We present results and source counts at 90micron extracted from the Preliminary Analysis of the European Large Area ISO Survey (ELAIS). The survey covered about 11.6 square degrees of the sky in four main areas and was carried out with the PHOT instrument onboard the Infrared Space Observatory (ISO). The survey is at least an order of magnitude deeper than the IRAS 100micron survey and is expected to provide constraints on the formation and evolution of galaxies. The majority of the detected sources are associated with galaxies on optical images. In some cases the optical associations are interacting pairs or small groups of galaxies suggesting the sample may include a significant fraction of luminous infrared galaxies. The source counts extracted from a reliable subset of the detected sources are in agreement with strongly evolving models of the starburst galaxy population.
[71]  oai:arXiv.org:astro-ph/0003198  [pdf] - 35072
The European Large Area ISO Survey II: mid-infrared extragalactic source counts
Comments: MNRAS in press. 14 pages, uses BoxedEPS (included). For more information on the ELAIS project see http://athena.ph.ic.ac.uk/
Submitted: 2000-03-14
We present preliminary source counts at 6.7um and 15um from the Preliminary Analysis of the European Large Area ISO survey, with limiting flux densities of \~2mJy at 15um & ~1mJy at 6.7um. We separate the stellar contribution from the extragalactic using identifications with APM sources made with the likelihood ratio technique. We quantify the completeness & reliability of our source extraction using (a) repeated observations over small areas, (b) cross-IDs with stars of known spectral type, (c) detections of the PSF wings around bright sources, (d) comparison with independent algorithms. Flux calibration at 15um was performed using stellar IDs; the calibration does not agree with the pre-flight estimates, probably due to effects of detector hysteresis and photometric aperture correction. The 6.7um extragalactic counts are broadly reproduced in the Pearson & Rowan-Robinson model, but the Franceschini et al. (1997) model underpredicts the observed source density by ~0.5-1 dex, though the photometry at 6.7um is still preliminary. At 15um the extragalactic counts are in excellent agreement with the predictions of the Pearson & Rowan-Robinson (1996), Franceschini et al. (1994), Guiderdoni et al. (1997) and the evolving models of Xu et al. (1998), over 7 orders of magnitude in 15um flux density. The counts agree with other estimates from the ISOCAM instrument at overlapping flux densities (Elbaz et al. 1999), provided a consistent flux calibration is used. Luminosity evolution at a rate of (1+z)^3, incorporating mid-IR spectral features, provides a better fit to the 15um differential counts than (1+z)^4 density evolution. No-evolution models are excluded, and implying that below around 10mJy at 15um the source counts become dominated by an evolving cosmological population of dust-shrouded starbursts and/or active galaxies.
[72]  oai:arXiv.org:astro-ph/9907248  [pdf] - 277216
The Very Energetic Radiation Imaging Telescope Array System (VERITAS)
Comments: 4 pages, 2 figures, to be published in the proceedings of the 26th ICRC (Salt Lake City, 1999)
Submitted: 1999-07-19
We give an overview of the current status and scientific goals of VERITAS, a proposed hexagonal array of seven 10 m aperture imaging Cherenkov telescopes. The selected site is Montosa Canyon (1390 m a.s.l.) at the Whipple Observatory, Arizona. Each telescope, of 12 m focal length, will initially be equipped with a 499 element photomultiplier camera covering a 3.5 degree field of view. A central station will initiate the readout of 500 MHz FADCs upon receipt of multiple telescope triggers. The minimum detectable flux sensitivity will be 0.5% of the Crab Nebula flux at 200 GeV. Detailed simulations of the array's performance are presented elsewhere at this meeting. VERITAS will operate primarily as a gamma-ray observatory in the 50 GeV to 50 TeV range for the study of active galaxies, supernova remnants, pulsars and gamma-ray bursts.