Normalized to: Sukhatme, K.
[1]
oai:arXiv.org:1508.02333 [pdf] - 1264202
The Mid-Infrared Instrument for JWST, II: Design and Build
Wright, G. S.;
Wright, David;
Goodson, G. B.;
Rieke, G. H.;
Aitink-Kroes, Gabby;
Amiaux, J.;
Aricha-Yanguas, Ana;
Azzolini, Ruyman;
Banks, Kimberly;
Barrado-Navascues, D.;
Belenguer-Davila, T.;
Bloemmart, J. A. D. L.;
Bouchet, Patrice;
Brandl, B. R.;
Colina, L.;
Detre, Ors;
Diaz-Catala, Eva;
Eccleston, Paul;
Friedman, Scott D.;
Garcia-Marin, Macarena;
Guedel, Manuel;
Glasse, Alistair;
Glauser, Adrian M.;
Greene, T. P.;
Groezinger, Uli;
Grundy, Tim;
Hastings, Peter;
Henning, Th.;
Hofferbert, Ralph;
Hunter, Faye;
Jessen, N. C.;
Justtanont, K.;
Karnik, Avinash R.;
Khorrami, Mori A.;
Krause, Oliver;
Labiano, Alvaro;
Lagage, P. -O.;
Langer, Ulrich;
Lemke, Dietrich;
Lim, Tanya;
Lorenzo-Alvarez, Jose;
Mazy, Emmanuel;
McGowan, Norman;
Meixner, M. E.;
Morris, Nigel;
Morrison, Jane E.;
Mueller, Friedrich;
Norgaard-Nielson, H. -U.;
Olofsson, Goeran;
O'Sullivan, Brian;
Pel, J. -W.;
Penanen, Konstantin;
Petach, M. B.;
Pye, J. P.;
Ray, T. P.;
Renotte, Etienne;
Renouf, Ian;
Ressler, M. E.;
Samara-Ratna, Piyal;
Scheithauer, Silvia;
Schneider, Analyn;
Shaughnessy, Bryan;
Stevenson, Tim;
Sukhatme, Kalyani;
Swinyard, Bruce;
Sykes, Jon;
Thatcher, John;
Tikkanen, Tuomo;
van Dishoeck, E. F.;
Waelkens, C.;
Walker, Helen;
Wells, Martyn;
Zhender, Alex
Submitted: 2015-08-10
The Mid-InfraRed Instrument (MIRI) on the James Webb Space Telescope (JWST)
provides measurements over the wavelength range 5 to 28.5 microns. MIRI has,
within a single 'package', four key scientific functions: photometric imaging,
coronagraphy, single-source low-spectral resolving power (R ~ 100)
spectroscopy, and medium-resolving power (R ~ 1500 to 3500) integral field
spectroscopy. An associated cooler system maintains MIRI at its operating
temperature of < 6.7 K. This paper describes the driving principles behind the
design of MIRI, the primary design parameters, and their realization in terms
of the 'as-built' instrument. It also describes the test program that led to
delivery of the tested and calibrated Flight Model to NASA in 2012, and the
confirmation after delivery of the key interface requirements.
[2]
oai:arXiv.org:1508.02362 [pdf] - 1264204
The Mid-Infrared Instrument for the James Webb Space Telescope, VII: The
MIRI Detectors
Rieke, G. H.;
Ressler, M. E.;
Morrison, Jane E.;
Bergeron, L.;
Bouchet, Patrice;
Garcıa-Marın, Macarena;
Greene, T. P.;
Regan, M. W.;
Sukhatme, K. G.;
Walker, Helen
Submitted: 2015-08-10
The MIRI Si:As IBC detector arrays extend the heritage technology from the
Spitzer IRAC arrays to a 1024 x 1024 pixel format. We provide a short
discussion of the principles of operation, design, and performance of the
individual MIRI detectors, in support of a description of their operation in
arrays provided in an accompanying paper (Ressler et al. (2015)). We then
describe modeling of their response. We find that electron diffusion is an
important component of their performance, although it was omitted in previous
models. Our new model will let us optimize the bias voltage while avoiding
avalanche gain. It also predicts the fraction of the IR-active layer that is
depleted (and thus contributes to the quantum efficiency) as signal is
accumulated on the array amplifier. Another set of models accurately predicts
the nonlinearity of the detector-amplifier unit and has guided determination of
the corrections for nonlinearity. Finally, we discuss how diffraction at the
interpixel gaps and total internal reflection can produce the extended
cross-like artifacts around images with these arrays at short wavelengths, ~ 5
microns. The modeling of the behavior of these devices is helping optimize how
we operate them and also providing inputs to the development of the data
pipeline.
[3]
oai:arXiv.org:1508.02417 [pdf] - 1264208
The Mid-Infrared Instrument for the James Webb Space Telescope, VIII:
The MIRI Focal Plane System
Ressler, M. E.;
Sukhatme, K. G.;
Franklin, B. R.;
Mahoney, J. C.;
Thelen, M. P.;
Bouchet, P.;
Colbert, J. W.;
Cracraft, Misty;
Dicken, D.;
Gastaud, R.;
Goodson, G. B.;
Eccleston, Paul;
Moreau, V.;
Rieke, G. H.;
Schneider, Analyn
Submitted: 2015-08-10
We describe the layout and unique features of the focal plane system for
MIRI. We begin with the detector array and its readout integrated circuit
(combining the amplifier unit cells and the multiplexer), the electronics, and
the steps by which the data collection is controlled and the output signals are
digitized and delivered to the JWST spacecraft electronics system. We then
discuss the operation of this MIRI data system, including detector readout
patterns, operation of subarrays, and data formats. Finally, we summarize the
performance of the system, including remaining anomalies that need to be
corrected in the data pipeline.
[4]
oai:arXiv.org:1005.5123 [pdf] - 1032799
The Herschel-SPIRE instrument and its in-flight performance
Griffin, M. J.;
Abergel, A.;
Abreu, A.;
Ade, P. A. R.;
André, P.;
Augueres, J. -L.;
Babbedge, T.;
Bae, Y.;
Baillie, T.;
Baluteau, J. -P.;
Barlow, M. J.;
Bendo, G.;
Benielli, D.;
Bock, J. J.;
Bonhomme, P.;
Brisbin, D.;
Brockley-Blatt, C.;
Caldwell, M.;
Cara, C.;
Castro-Rodriguez, N.;
Cerulli, R.;
Chanial, P.;
Chen, S.;
Clark, E.;
Clements, D. L.;
Clerc, L.;
Coker, J.;
Communal, D.;
Conversi, L.;
Cox, P.;
Crumb, D.;
Cunningham, C.;
Daly, F.;
Davis, G. R.;
De Antoni, P.;
Delderfield, J.;
Devin, N.;
Di Giorgio, A.;
Didschuns, I.;
Dohlen, K.;
Donati, M.;
Dowell, A.;
Dowell, C. D.;
Duband, L.;
Dumaye, L.;
Emery, R. J.;
Ferlet, M.;
Ferrand, D.;
Fontignie, J.;
Fox, M.;
Franceschini, A.;
Frerking, M.;
Fulton, T.;
Garcia, J.;
Gastaud, R.;
Gear, W. K.;
Glenn, J.;
Goizel, A.;
Griffin, D. K.;
Grundy, T.;
Guest, S.;
Guillemet, L.;
Hargrave, P. C.;
Harwit, M.;
Hastings, P.;
Hatziminaoglou, E.;
Herman, M.;
Hinde, B.;
Hristov, V.;
Huang, M.;
Imhof, P.;
Isaak, K. J.;
Israelsson, U.;
Ivison, R. J.;
Jennings, D.;
Kiernan, B.;
King, K. J.;
Lange, A. E.;
Latter, W.;
Laurent, G.;
Laurent, P.;
Leeks, S. J.;
Lellouch, E.;
Levenson, L.;
Li, B.;
Li, J.;
Lilienthal, J.;
Lim, T.;
Liu, J.;
Lu, N.;
Madden, S.;
Mainetti, G.;
Marliani, P.;
McKay, D.;
Mercier, K.;
Molinari, S.;
Morris, H.;
Moseley, H.;
Mulder, J.;
Mur, M.;
Naylor, D. A.;
Nguyen, H.;
O'Halloran, B.;
Oliver, S.;
Olofsson, G.;
Olofsson, H. -G.;
Orfei, R.;
Page, M. J.;
Pain, I.;
Panuzzo, P.;
Papageorgiou, A.;
Parks, G.;
Parr-Burman, P.;
Pearce, A.;
Pearson, C.;
Pérez-Fournon, I.;
Pinsard, F.;
Pisano, G.;
Podosek, J.;
Pohlen, M.;
Polehampton, E. T.;
Pouliquen, D.;
Rigopoulou, D.;
Rizzo, D.;
Roseboom, I. G.;
Roussel, H.;
Rowan-Robinson, M.;
Rownd, B.;
Saraceno, P.;
Sauvage, M.;
Savage, R.;
Savini, G.;
Sawyer, E.;
Scharmberg, C.;
Schmitt, D.;
Schneider, N.;
Schulz, B.;
Schwartz, A.;
Shafer, R.;
Shupe, D. L.;
Sibthorpe, B.;
Sidher, S.;
Smith, A.;
Smith, A. J.;
Smith, D.;
Spencer, L.;
Stobie, B.;
Sudiwala, R.;
Sukhatme, K.;
Surace, C.;
Stevens, J. A.;
Swinyard, B. M.;
Trichas, M.;
Tourette, T.;
Triou, H.;
Tseng, S.;
Tucker, C.;
Turner, A.;
Vaccari, M.;
Valtchanov, I.;
Vigroux, L.;
Virique, E.;
Voellmer, G.;
Walker, H.;
Ward, R.;
Waskett, T.;
Weilert, M.;
Wesson, R.;
White, G. J.;
Whitehouse, N.;
Wilson, C. D.;
Winter, B.;
Woodcraft, A. L.;
Wright, G. S.;
Xu, C. K.;
Zavagno, A.;
Zemcov, M.;
Zhang, L.;
Zonca, E.
Submitted: 2010-05-27
The Spectral and Photometric Imaging Receiver (SPIRE), is the Herschel Space
Observatory`s submillimetre camera and spectrometer. It contains a three-band
imaging photometer operating at 250, 350 and 500 microns, and an imaging
Fourier Transform Spectrometer (FTS) which covers simultaneously its whole
operating range of 194-671 microns (447-1550 GHz). The SPIRE detectors are
arrays of feedhorn-coupled bolometers cooled to 0.3 K. The photometer has a
field of view of 4' x 8', observed simultaneously in the three spectral bands.
Its main operating mode is scan-mapping, whereby the field of view is scanned
across the sky to achieve full spatial sampling and to cover large areas if
desired. The spectrometer has an approximately circular field of view with a
diameter of 2.6'. The spectral resolution can be adjusted between 1.2 and 25
GHz by changing the stroke length of the FTS scan mirror. Its main operating
mode involves a fixed telescope pointing with multiple scans of the FTS mirror
to acquire spectral data. For extended source measurements, multiple position
offsets are implemented by means of an internal beam steering mirror to achieve
the desired spatial sampling and by rastering of the telescope pointing to map
areas larger than the field of view. The SPIRE instrument consists of a cold
focal plane unit located inside the Herschel cryostat and warm electronics
units, located on the spacecraft Service Module, for instrument control and
data handling. Science data are transmitted to Earth with no on-board data
compression, and processed by automatic pipelines to produce calibrated science
products. The in-flight performance of the instrument matches or exceeds
predictions based on pre-launch testing and modelling: the photometer
sensitivity is comparable to or slightly better than estimated pre-launch, and
the spectrometer sensitivity is also better by a factor of 1.5-2.