Stutzmann, J. -S.
Normalized to: Stutzmann, J.
1 article(s) in total. 17 co-authors. Median position in authors list is 13,0.
[1]
oai:arXiv.org:1205.3874 [pdf] - 514228
Improvement of xenon purification system using a combination of a pulse
tube refrigerator and a coaxial heat exchanger
Chen, Wan-Ting;
Chbib, D.;
Cussonneau, J. -P.;
Donnard, J.;
Duval, S.;
Lemaire, O.;
Calloch, M. Le;
Ray, P. Le;
Mohamad-Hadi, A. -F.;
Morteau, E.;
Oger, T.;
Scotto-Lavina, L.;
Stutzmann, J. -S.;
Thers, D.;
Briend, P.;
Haruyama, T.;
Mihara, S.;
Tauchi, T.
Submitted: 2012-05-17
We have developed a compact cryogenic system with a pulse tube refrigerator
and a coaxial heat exchanger. This liquefaction-purification system not only
saves the cooling power used to reach high gaseous recirculation rate, but also
reduces the impurity level with high speed. The heat exchanger operates with an
efficiency of 99%, which indicates the possibility for fast xenon gas
recirculation in a highpressurized large-scale xenon storage with much less
thermal losses.