sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Stuhlinger, M.

Normalized to: Stuhlinger, M.

9 article(s) in total. 116 co-authors, from 1 to 3 common article(s). Median position in authors list is 10,0.

[1]  oai:arXiv.org:1609.07530  [pdf] - 1528237
GRS 1739-278 observed at very low luminosity with XMM-Newton and NuSTAR
Comments: 7 pages, 3 figures, accepted for publication in ApJ
Submitted: 2016-09-23
We present a detailed spectral analysis of XMM-Newton and NuSTAR observations of the accreting transient black hole GRS 1739-278 during a very faint low hard state at ~0.02% of the Eddington luminosity (for a distance of 8.5 kpc and a mass of 10 M_sun ). The broad-band X-ray spectrum between 0.5-60 keV can be well-described by a power law continuum with an exponential cutoff. The continuum is unusually hard for such a low luminosity, with a photon index of Gamma = 1.39 +/- 0.04. We find evidence for an additional reflection component from an optically thick accretion disk at the 98% likelihood level. The reflection fraction is low with R_refl = 0.043(+0.033,-0.023). In combination with measurements of the spin and inclination parameters made with NuSTAR during a brighter hard state by Miller and co-workers, we seek to constrain the accretion disk geometry. Depending on the assumed emissivity profile of the accretion disk, we find a truncation radius of 15-35 Rg (5-12 R_ISCO ) at the 90% confidence limit. These values depend strongly on the assumptions and we discuss possible systematic uncertainties.
[2]  oai:arXiv.org:1602.01148  [pdf] - 1354893
Eta Carinae's Thermal X-ray Tail Measured with XMM-Newton and NuSTAR
Comments: 24 pages, 6 figures, 2 tables
Submitted: 2016-02-02
The evolved, massive highly eccentric binary system, eta Carinae, underwent a periastron passage in the summer of 2014. We obtained two coordinated X-ray observations with XMM-Newton and NuSTAR during the elevated X-ray flux state and just before the X-ray minimum flux state around this passage. These NuSTAR observations clearly detected X-ray emission associated with eta Car extending up to ~50 keV for the first time. The NuSTAR spectrum above 10 keV can be fit with the bremsstrahlung tail from a kT ~6 keV plasma. This temperature is Delta kT ~2 keV higher than those measured from the iron K emission line complex, if the shocked gas is in collisional ionization equilibrium. This result may suggest that the companion star's pre-shock wind velocity is underestimated. The NuSTAR observation near the X-ray minimum state showed a gradual decline in the X-ray emission by 40% at energies above 5 keV in a day, the largest rate of change of the X-ray flux yet observed in individual eta Car observations. The column density to the hardest emission component, NH ~1e24 cm-2, marked one of the highest values ever observed for eta Car, strongly suggesting increased obscuration of the wind-wind colliding X-ray emission by the thick primary stellar wind prior to superior conjunction. Neither observation detected the power-law component in the extremely hard band that INTEGRAL and Suzaku observed prior to 2011. If the non-detection by NuSTAR is caused by absorption, the power-law source must be small and located very near the WWC apex. Alternatively, it may be that the power-law source is not related to either eta Car or the GeV gamma-ray source.
[3]  oai:arXiv.org:1406.3345  [pdf] - 1210126
The 2-79 keV X-ray Spectrum of the Circinus Galaxy with NuSTAR, XMM-Newton and Chandra: a Fully Compton-Thick AGN
Comments: Accepted for publication in ApJ
Submitted: 2014-06-12
The Circinus galaxy is one of the nearest obscured AGN, making it an ideal target for detailed study. Combining archival Chandra and XMM-Newton data with new NuSTAR observations, we model the 2-79 keV spectrum to constrain the primary AGN continuum and to derive physical parameters for the obscuring material. Chandra's high angular resolution allows a separation of nuclear and off-nuclear galactic emission. In the off-nuclear diffuse emission we find signatures of strong cold reflection, including high equivalent-width neutral Fe lines. This Compton-scattered off-nuclear emission amounts to 18% of the nuclear flux in the Fe line region, but becomes comparable to the nuclear emission above 30 keV. The new analysis no longer supports a prominent transmitted AGN component in the observed band. We find that the nuclear spectrum is consistent with Compton-scattering by an optically-thick torus, where the intrinsic spectrum is a powerlaw of photon index $\Gamma = 2.2-2.4$, the torus has an equatorial column density of $N_{\rm H} = (6-10)\times10^{24}$cm$^{-2}$ and the intrinsic AGN $2-10$ keV luminosity is $(2.3-5.1)\times 10^{42}$ erg/s. These values place Circinus along the same relations as unobscured AGN in accretion rate-vs-$\Gamma$ and $L_X$-vs-$L_{IR}$ phase space. NuSTAR's high sensitivity and low background allow us to study the short time-scale variability of Circinus at X-ray energies above 10 keV for the first time. The lack of detected variability favors a Compton-thick absorber, in line with the the spectral fitting results.
[4]  oai:arXiv.org:1401.2848  [pdf] - 820745
The accretion environment in Vela X-1 during a flaring period using XMM-Newton
Comments: Accepted. Astronomy and Astrophysics, 2013
Submitted: 2014-01-13, last modified: 2014-02-18
We present analysis of 100 ks contiguous XMM-Newton data of the prototypical wind accretor Vela X-1. The observation covered eclipse egress between orbital phases 0.134 and 0.265, during which a giant flare took place, enabling us to study the spectral properties both outside and during the flare. This giant flare with a peak luminosity of $3.92^{+0.42}_{-0.09} \times 10^{37}$ erg s$^{-1}$ allows estimates of the physical parameters of the accreted structure with a mass of $\sim$ $10^{21}$ g. We have been able to model several contributions to the observed spectrum with a phenomenological model formed by three absorbed power laws plus three emission lines. After analysing the variations with orbital phase of the column density of each component, as well as those in the Fe and Ni fluorescence lines, we provide a physical interpretation for each spectral component. Meanwhile, the first two components are two aspects of the principal accretion component from the surface of the neutron star, and the third component seems to be the \textit{X-ray light echo} formed in the stellar wind of the companion.
[5]  oai:arXiv.org:1204.0978  [pdf] - 1117770
The relative and absolute timing accuracy of the EPIC-pn camera on XMM-Newton, from X-ray pulsations of the Crab and other pulsars
Comments: 16 pages, 9 figures. Accepted for publication on A&A
Submitted: 2012-04-04
Reliable timing calibration is essential for the accurate comparison of XMM-Newton light curves with those from other observatories, to ultimately use them to derive precise physical quantities. The XMM-Newton timing calibration is based on pulsar analysis. However, as pulsars show both timing noise and glitches, it is essential to monitor these calibration sources regularly. To this end, the XMM-Newton observatory performs observations twice a year of the Crab pulsar to monitor the absolute timing accuracy of the EPIC-pn camera in the fast Timing and Burst modes. We present the results of this monitoring campaign, comparing XMM-Newton data from the Crab pulsar (PSR B0531+21) with radio measurements. In addition, we use five pulsars (PSR J0537-69, PSR B0540-69, PSR B0833-45, PSR B1509-58 and PSR B1055-52) with periods ranging from 16 ms to 197 ms to verify the relative timing accuracy. We analysed 38 XMM-Newton observations (0.2-12.0 keV) of the Crab taken over the first ten years of the mission and 13 observations from the five complementary pulsars. All the data were processed with the SAS, the XMM-Newton Scientific Analysis Software, version 9.0. Epoch folding techniques coupled with \chi^{2} tests were used to derive relative timing accuracies. The absolute timing accuracy was determined using the Crab data and comparing the time shift between the main X-ray and radio peaks in the phase folded light curves. The relative timing accuracy of XMM-Newton is found to be better than 10^{-8}. The strongest X-ray pulse peak precedes the corresponding radio peak by 306\pm9 \mus, which is in agreement with other high energy observatories such as Chandra, INTEGRAL and RXTE. The derived absolute timing accuracy from our analysis is \pm48 \mus.
[6]  oai:arXiv.org:astro-ph/0701825  [pdf] - 88954
2003--2005 INTEGRAL and XMM-Newton observations of 3C 273
Comments: 11 pages, accepted to A&A
Submitted: 2007-01-29
The aim of this paper is to study the evolution of the broadband spectrum of one of the brightest and nearest quasars 3C 273. We analyze the data obtained during quasi-simultaneous INTEGRAL and XMM monitoring of the blazar 3C 273 in 2003--2005 in the UV, X-ray and soft gamma-ray bands and study the results in the context of the long-term evolution of the source. The 0.2-100 keV spectrum of the source is well fitted by a combination of a soft cut-off power law and a hard power law. No improvement of the fit is achieved if one replaces the soft cut-off power law by either a blackbody, or a disk reflection model. During the observation period the source has reached the historically softest state in the hard X-ray domain with a photon index $\Gamma=1.82\pm 0.01$. Comparing our data with available archived X-ray data from previous years, we find a secular evolution of the source toward softer X-ray emission (the photon index has increased by $\Delta\Gamma\simeq 0.3-0.4$ over the last thirty years). We argue that existing theoretical models have to be significantly modified to account for the observed spectral evolution of the source.
[7]  oai:arXiv.org:astro-ph/0511395  [pdf] - 77753
Status of the XMM-Newton cross-calibration with SASv6.5.0
Comments: 6 pages, 23 figures. To appear in the proceedings of "The X-Ray Universe 2005" conference, 2005 Sept 26-30, El Escorial, Madrid, Spain
Submitted: 2005-11-14
Further achievements of the XMM-Newton cross-calibration - XMM internal as well as with other X-ray missions - are presented. We explain the major changes in the new version SASv6.5 of the XMM-Newton science analysis system. The current status of the cross-calibration of the three EPIC cameras is shown. Using a large sample of blazars, the pn energy redistribution at low energy could be further calibrated, correcting the overestimation of fluxes in the lowest energy regime. In the central CCDs of the MOSs, patches were identified at the bore-sight positions, leading to an underestimation of the low energy fluxes. The further improvement in the understanding of the cameras resulted in a good agreement of the EPIC instruments down to lowest energies. The latest release of the SAS software package already includes corrections for both effects as shown in several examples of different types of sources. Finally the XMM internal cross-calibration is completed by the presentation of the current cross-calibration status between EPIC and RGS instruments. Major efforts have been made in cross-calibrations with other X-ray missions, most importantly with Chandra, of course, but also with currently observing satellites like Swift.
[8]  oai:arXiv.org:astro-ph/0312148  [pdf] - 61361
XMM-Newton observations of 3C 273
Comments: 12 pages, 19 figures, accepted for publication in MNRAS
Submitted: 2003-12-05
A series of nine XMM-Newton observations of the radio-loud quasar 3C 273 are presented, concentrating mainly on the soft excess. Although most of the individual observations do not show evidence for iron emission, co-adding them reveals a weak, broad line (EW ~ 56 eV). The soft excess component is found to vary, confirming previous work, and can be well fitted with multiple blackbody components, with temperatures ranging between ~40 and ~330 eV, together with a power-law. Alternatively, a Comptonisation model also provides a good fit, with a mean electron temperature of ~350 eV, although this value is higher when the soft excess is more luminous over the 0.5-10 keV energy band. In the RGS spectrum of 3C 273, a strong detection of the OVII He-alpha absorption line at zero redshift is made; this may originate in warm gas in the local intergalactic medium, consistent with the findings of both Fang et al. (2003) and Rasmussen et al. (2003).
[9]  oai:arXiv.org:astro-ph/0308212  [pdf] - 58491
Simultaneous observations of the quasar 3C 273 with INTEGRAL, XMM-Newton and RXTE
Comments: 4 figures, accepted for publication in A+A letters
Submitted: 2003-08-12
INTEGRAL has observed the bright quasar 3C 273 on 3 epochs in January 2003 as one of the first observations of the open programme. The observation on January 5 was simultaneous with RXTE and XMM-Newton observations. We present here a first analysis of the continuum emission as observed by these 3 satellites in the band from 3 keV to 500 keV. The continuum spectral energy distribution of 3C 273 was observed to be weak and steep in the high energies during this campaign. We present the actual status of the cross calibrations between the instruments on the three platforms using the calibrations available in June 2003.