[1]  oai:arXiv.org:1201.6289  [pdf] - 476260
Code-division multiplexing for x-ray microcalorimeters
Comments: To be published in Applied Physics Letters
Submitted: 2012-01-30
We demonstrate the code-division multiplexed (CDM) readout of eight transition-edge sensor microcalorimeters. The energy resolution is 3.0 eV (full width at half-maximum) or better at 5.9 keV, with a best resolution of 2.3 eV and a mean of 2.6 eV over the seven modulated detectors. The flux-summing CDM system is described and compared with similar time-division multiplexed (TDM) readout. We show that the sqrt(Npixels) multiplexing disadvantage associated with TDM is not present in CDM. This demonstration establishes CDM as both a simple route to higher performance in existing TDM microcalorimetric experiments and a long-term approach to reaching higher multiplexing factors.
[2]  oai:arXiv.org:1110.2531  [pdf] - 507871
Optimization and analysis of code-division multiplexed TES microcalorimeters
Comments: 7 pages, 5 figures. Presented at the 14th International Workshop on Low Temperature Detectors, Heidelberg University, August 1-5, 2011, proceedings to be published in the Journal of Low Temperature Physics
Submitted: 2011-10-11
We are developing code-division multiplexing (CDM) systems for transition-edge sensor arrays with the goal of reaching multiplexing factors in the hundreds. We report on x-ray measurements made with a four-channel prototype CDM system that employs a flux-summing architecture, emphasizing data-analysis issues. We describe an empirical method to determine the demodulation matrix that minimizes cross-talk. This CDM system achieves energy resolutions of between 2.3 eV and 3.0 eV FWHM at 5.9 keV.
[3]  oai:arXiv.org:1008.5106  [pdf] - 1034561
Time-division SQUID multiplexers with reduced sensitivity to external magnetic fields
Comments: 4 pages, 7 figures. Submitted for publication in the IEEE Transactions on Applied Superconductivity, August 2010
Submitted: 2010-08-30
Time-division SQUID multiplexers are used in many applications that require exquisite control of systematic error. One potential source of systematic error is the pickup of external magnetic fields in the multiplexer. We present measurements of the field sensitivity figure of merit, effective area, for both the first stage and second stage SQUID amplifiers in three NIST SQUID multiplexer designs. These designs include a new variety with improved gradiometry that significantly reduces the effective area of both the first and second stage SQUID amplifiers.