Normalized to: Stevenson, T.
[1]
oai:arXiv.org:1912.07118 [pdf] - 2050303
The Experiment for Cryogenic Large-aperture Intensity Mapping (EXCLAIM)
Ade, P. A. R.;
Anderson, C. J.;
Barrentine, E. M.;
Bellis, N. G.;
Bolatto, A. D.;
Breysse, P. C.;
Bulcha, B. T.;
Cataldo, G.;
Connors, J. A.;
Cursey, P. W.;
Ehsan, N.;
Grant, H. C.;
Essinger-Hileman, T. M.;
Hess, L. A.;
Kimball, M. O.;
Kogut, A. J.;
Lamb, A. D.;
Lowe, L. N.;
Mauskopf, P. D.;
McMahon, J.;
Mirzaei, M.;
Moseley, S. H.;
Mugge-Durum, J. W.;
Noroozian, O.;
Pen, U.;
Pullen, A. R.;
Rodriguez, S.;
Shirron, P. J.;
Somerville, R. S.;
Stevenson, T. R.;
Switzer, E. R.;
Tucker, C.;
Visbal, E.;
Volpert, C. G.;
Wollack, E. J.;
Yang, S.
Submitted: 2019-12-15
The EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM) is a
cryogenic balloon-borne instrument that will survey galaxy and star formation
history over cosmological time scales. Rather than identifying individual
objects, EXCLAIM will be a pathfinder to demonstrate an intensity mapping
approach, which measures the cumulative redshifted line emission. EXCLAIM will
operate at 420-540 GHz with a spectral resolution R=512 to measure the
integrated CO and [CII] in redshift windows spanning 0 < z < 3.5. CO and [CII]
line emissions are key tracers of the gas phases in the interstellar medium
involved in star-formation processes. EXCLAIM will shed light on questions such
as why the star formation rate declines at z < 2, despite continued clustering
of the dark matter. The instrument will employ an array of six superconducting
integrated grating-analog spectrometers (micro-spec) coupled to microwave
kinetic inductance detectors (MKIDs). Here we present an overview of the
EXCLAIM instrument design and status.
[2]
oai:arXiv.org:1611.04466 [pdf] - 1513841
Multimode bolometer development for the PIXIE instrument
Submitted: 2016-11-14
The Primordial Inflation Explorer (PIXIE) is an Explorer-class mission
concept designed to measure the polarization and absolute intensity of the
cosmic microwave background. In the following, we report on the design,
fabrication, and performance of the multimode polarization-sensitive bolometers
for PIXIE, which are based on silicon thermistors. In particular we focus on
several recent advances in the detector design, including the implementation of
a scheme to greatly raise the frequencies of the internal vibrational modes of
the large-area, low-mass optical absorber structure consisting of a grid of
micromachined, ion-implanted silicon wires. With $\sim30$ times the absorbing
area of the spider-web bolometers used by Planck, the tensioning scheme enables
the PIXIE bolometers to be robust in the vibrational and acoustic environment
at launch of the space mission. More generally, it could be used to reduce
microphonic sensitivity in other types of low temperature detectors. We also
report on the performance of the PIXIE bolometers in a dark cryogenic
environment.
[3]
oai:arXiv.org:1608.08891 [pdf] - 1531422
Silicon-Based Antenna-Coupled Polarization-Sensitive Millimeter-Wave
Bolometer Arrays for Cosmic Microwave Background Instruments
Rostem, Karwan;
Ali, Aamir;
Appel, John W.;
Bennett, Charles L.;
Brown, Ari;
Chang, Meng-Ping;
Chuss, David T.;
Colazo, Felipe A.;
Costen, Nick;
Denis, Kevin L.;
Essinger-Hileman, Tom;
Hu, Ron;
Marriage, Tobias A.;
Moseley, Samuel H.;
Stevenson, Thomas R.;
U-Yen, Kongpop;
Wollack, Edward J.;
Xu, Zhilei
Submitted: 2016-08-30
We describe feedhorn-coupled polarization-sensitive detector arrays that
utilize monocrystalline silicon as the dielectric substrate material.
Monocrystalline silicon has a low-loss tangent and repeatable dielectric
constant, characteristics that are critical for realizing efficient and uniform
superconducting microwave circuits. An additional advantage of this material is
its low specific heat. In a detector pixel, two Transition-Edge Sensor (TES)
bolometers are antenna-coupled to in-band radiation via a symmetric planar
orthomode transducer (OMT). Each orthogonal linear polarization is coupled to a
separate superconducting microstrip transmission line circuit. On-chip
filtering is employed to both reject out-of-band radiation from the upper band
edge to the gap frequency of the niobium superconductor, and to flexibly define
the bandwidth for each TES to meet the requirements of the application. The
microwave circuit is compatible with multi-chroic operation. Metalized silicon
platelets are used to define the backshort for the waveguide probes. This
micro-machined structure is also used to mitigate the coupling of out-of-band
radiation to the microwave circuit. At 40 GHz, the detectors have a measured
efficiency of 90%. In this paper, we describe the development of the 90 GHz
detector arrays that will be demonstrated using the Cosmology Large Angular
Scale Surveyor (CLASS) ground-based telescope.
[4]
oai:arXiv.org:1607.05708 [pdf] - 1459425
Detectors and cooling technology for direct spectroscopic biosignature
characterization
Submitted: 2016-07-19, last modified: 2016-08-19
Direct spectroscopic biosignature characterization (hereafter "biosignature
characterization") will be a major focus for future space observatories
equipped with coronagraphs or starshades. Our aim in this article is to provide
an introduction to potential detector and cooling technologies for biosignature
characterization. We begin by reviewing the needs. These include nearly
noiseless photon detection at flux levels as low as
$<0.001~\textrm{photons}~s^{-1}~\textrm{pixel}^{-1}$ in the visible and
near-IR. We then discuss potential areas for further testing and/or development
to meet these needs using non-cryogenic detectors (EMCCD, HgCdTe array, HgCdTe
APD array), and cryogenic single photon detectors (MKID arrays and TES
microcalorimeter arrays). Non-cryogenic detectors are compatible with the
passive cooling that is strongly preferred by coronagraphic missions, but would
add non-negligible noise. Cryogenic detectors would require active cooling, but
in return deliver nearly quantum limited performance. Based on the flight
dynamics of past NASA missions, we discuss reasonable vibration expectations
for a large UV-Optical-IR space telescope (LUVOIR) and preliminary cooling
concepts that could potentially fit into a vibration budget without being the
largest element. We believe that a cooler that meets the stringent vibration
needs of a LUVOIR is also likely to meet those of a starshade-based Habitable
Exoplanet Imaging Mission.
[5]
oai:arXiv.org:1508.02333 [pdf] - 1264202
The Mid-Infrared Instrument for JWST, II: Design and Build
Wright, G. S.;
Wright, David;
Goodson, G. B.;
Rieke, G. H.;
Aitink-Kroes, Gabby;
Amiaux, J.;
Aricha-Yanguas, Ana;
Azzolini, Ruyman;
Banks, Kimberly;
Barrado-Navascues, D.;
Belenguer-Davila, T.;
Bloemmart, J. A. D. L.;
Bouchet, Patrice;
Brandl, B. R.;
Colina, L.;
Detre, Ors;
Diaz-Catala, Eva;
Eccleston, Paul;
Friedman, Scott D.;
Garcia-Marin, Macarena;
Guedel, Manuel;
Glasse, Alistair;
Glauser, Adrian M.;
Greene, T. P.;
Groezinger, Uli;
Grundy, Tim;
Hastings, Peter;
Henning, Th.;
Hofferbert, Ralph;
Hunter, Faye;
Jessen, N. C.;
Justtanont, K.;
Karnik, Avinash R.;
Khorrami, Mori A.;
Krause, Oliver;
Labiano, Alvaro;
Lagage, P. -O.;
Langer, Ulrich;
Lemke, Dietrich;
Lim, Tanya;
Lorenzo-Alvarez, Jose;
Mazy, Emmanuel;
McGowan, Norman;
Meixner, M. E.;
Morris, Nigel;
Morrison, Jane E.;
Mueller, Friedrich;
Norgaard-Nielson, H. -U.;
Olofsson, Goeran;
O'Sullivan, Brian;
Pel, J. -W.;
Penanen, Konstantin;
Petach, M. B.;
Pye, J. P.;
Ray, T. P.;
Renotte, Etienne;
Renouf, Ian;
Ressler, M. E.;
Samara-Ratna, Piyal;
Scheithauer, Silvia;
Schneider, Analyn;
Shaughnessy, Bryan;
Stevenson, Tim;
Sukhatme, Kalyani;
Swinyard, Bruce;
Sykes, Jon;
Thatcher, John;
Tikkanen, Tuomo;
van Dishoeck, E. F.;
Waelkens, C.;
Walker, Helen;
Wells, Martyn;
Zhender, Alex
Submitted: 2015-08-10
The Mid-InfraRed Instrument (MIRI) on the James Webb Space Telescope (JWST)
provides measurements over the wavelength range 5 to 28.5 microns. MIRI has,
within a single 'package', four key scientific functions: photometric imaging,
coronagraphy, single-source low-spectral resolving power (R ~ 100)
spectroscopy, and medium-resolving power (R ~ 1500 to 3500) integral field
spectroscopy. An associated cooler system maintains MIRI at its operating
temperature of < 6.7 K. This paper describes the driving principles behind the
design of MIRI, the primary design parameters, and their realization in terms
of the 'as-built' instrument. It also describes the test program that led to
delivery of the tested and calibrated Flight Model to NASA in 2012, and the
confirmation after delivery of the key interface requirements.
[6]
oai:arXiv.org:1408.4788 [pdf] - 1216429
CLASS: The Cosmology Large Angular Scale Surveyor
Essinger-Hileman, Thomas;
Ali, Aamir;
Amiri, Mandana;
Appel, John W.;
Araujo, Derek;
Bennett, Charles L.;
Boone, Fletcher;
Chan, Manwei;
Cho, Hsiao-Mei;
Chuss, David T.;
Colazo, Felipe;
Crowe, Erik;
Denis, Kevin;
Dünner, Rolando;
Eimer, Joseph;
Gothe, Dominik;
Halpern, Mark;
Harrington, Kathleen;
Hilton, Gene;
Hinshaw, Gary F.;
Huang, Caroline;
Irwin, Kent;
Jones, Glenn;
Karakla, John;
Kogut, Alan J.;
Larson, David;
Limon, Michele;
Lowry, Lindsay;
Marriage, Tobias;
Mehrle, Nicholas;
Miller, Amber D.;
Miller, Nathan;
Moseley, Samuel H.;
Novak, Giles;
Reintsema, Carl;
Rostem, Karwan;
Stevenson, Thomas;
Towner, Deborah;
U-Yen, Kongpop;
Wagner, Emily;
Watts, Duncan;
Wollack, Edward;
Xu, Zhilei;
Zeng, Lingzhen
Submitted: 2014-08-20
The Cosmology Large Angular Scale Surveyor (CLASS) is an experiment to
measure the signature of a gravita-tional-wave background from inflation in the
polarization of the cosmic microwave background (CMB). CLASS is a
multi-frequency array of four telescopes operating from a high-altitude site in
the Atacama Desert in Chile. CLASS will survey 70\% of the sky in four
frequency bands centered at 38, 93, 148, and 217 GHz, which are chosen to
straddle the Galactic-foreground minimum while avoiding strong atmospheric
emission lines. This broad frequency coverage ensures that CLASS can
distinguish Galactic emission from the CMB. The sky fraction of the CLASS
survey will allow the full shape of the primordial B-mode power spectrum to be
characterized, including the signal from reionization at low $\ell$. Its unique
combination of large sky coverage, control of systematic errors, and high
sensitivity will allow CLASS to measure or place upper limits on the
tensor-to-scalar ratio at a level of $r=0.01$ and make a
cosmic-variance-limited measurement of the optical depth to the surface of last
scattering, $\tau$.
[7]
oai:arXiv.org:1408.4790 [pdf] - 1216431
Scalable background-limited polarization-sensitive detectors for mm-wave
applications
Rostem, Karwan;
Ali, Aamir;
Appel, John W.;
Bennett, Charles L.;
Chuss, David T.;
Colazo, Felipe A.;
Crowe, Erik;
Denis, Kevin L.;
Essinger-Hileman, Tom;
Marriage, Tobias A.;
Moseley, Samuel H.;
Stevenson, Thomas R.;
Towner, Deborah W.;
U-Yen, Kongpop;
Wollack, Edward J.
Submitted: 2014-08-20
We report on the status and development of polarization-sensitive detectors
for millimeter-wave applications. The detectors are fabricated on
single-crystal silicon, which functions as a low-loss dielectric substrate for
the microwave circuitry as well as the supporting membrane for the
Transition-Edge Sensor (TES) bolometers. The orthomode transducer (OMT) is
realized as a symmetric structure and on-chip filters are employed to define
the detection bandwidth. A hybridized integrated enclosure reduces the
high-frequency THz mode set that can couple to the TES bolometers. An
implementation of the detector architecture at Q-band achieves 90% efficiency
in each polarization. The design is scalable in both frequency coverage, 30-300
GHz, and in number of detectors with uniform characteristics. Hence, the
detectors are desirable for ground-based or space-borne instruments that
require large arrays of efficient background-limited cryogenic detectors.
[8]
oai:arXiv.org:1403.1326 [pdf] - 800770
Precision control of thermal transport in cryogenic single-crystal
silicon devices
Submitted: 2014-03-05
We report on the diffusive-ballistic thermal conductance of multi-moded
single-crystal silicon beams measured below 1 K. It is shown that the phonon
mean-free-path $\ell$ is a strong function of the surface roughness
characteristics of the beams. This effect is enhanced in diffuse beams with
lengths much larger than $\ell$, even when the surface is fairly smooth, 5-10
nm rms, and the peak thermal wavelength is 0.6 $\mu$m. Resonant phonon
scattering has been observed in beams with a pitted surface morphology and
characteristic pit depth of 30 nm. Hence, if the surface roughness is not
adequately controlled, the thermal conductance can vary significantly for
diffuse beams fabricated across a wafer. In contrast, when the beam length is
of order $\ell$, the conductance is dominated by ballistic transport and is
effectively set by the beam area. We have demonstrated a uniformity of $\pm$8%
in fractional deviation for ballistic beams, and this deviation is largely set
by the thermal conductance of diffuse beams that support the
micro-electro-mechanical device and electrical leads. In addition, we have
found no evidence for excess specific heat in single-crystal silicon membranes.
This allows for the precise control of the device heat capacity with normal
metal films. We discuss the results in the context of the design and
fabrication of large-format arrays of far-infrared and millimeter wavelength
cryogenic detectors.
[9]
oai:arXiv.org:1401.1859 [pdf] - 849424
Angular and Polarization Response of Multimode Sensors with
Resistive-Grid Absorbers
Submitted: 2014-01-08
High sensitivity receiver systems with near ideal polarization sensitivity
are highly desirable for development of millimeter and sub-millimeter radio
astronomy. Multimoded bolometers provide a unique solution to achieve such
sensitivity, for which hundreds of single-mode sensors would otherwise be
required. The primary concern in employing such multimoded sensors for
polarimetery is the control of the polarization systematics. In this paper, we
examine the angular- and polarization- dependent absorption pattern of a thin
resistive grid or membrane, which models an absorber used for a multimoded
bolometer. The result shows that a freestanding thin resistive absorber with a
surface resistivity of \eta/2, where \eta\ is the impedance of free space,
attains a beam pattern with equal E- and H-plane responses, leading to zero
cross polarization. For a resistive-grid absorber, the condition is met when a
pair of grids is positioned orthogonal to each other and both have a
resistivity of \eta/2. When a reflective backshort termination is employed to
improve absorption efficiency, the cross-polar level can be suppressed below
-30 dB if acceptance angle of the sensor is limited to <60degrees. The small
cross-polar systematics have even-parity patterns and do not contaminate the
measurements of odd-parity polarization patterns, for which many of recent
instruments for cosmic microwave background are designed. Underlying symmetry
that suppresses these cross-polar systematics is discussed in detail. The
estimates and formalism provided in this paper offer key tools in the design
consideration of the instruments using the multimoded polarimeters.
[10]
oai:arXiv.org:astro-ph/0609546 [pdf] - 85138
PAPPA: Primordial Anisotropy Polarization Pathfinder Array
Kogut, A.;
Chuss, D. T.;
Fixsen, D.;
Hinshaw, G. F.;
Limon, M.;
Moseley, S. H.;
Phillips, N.;
Sharp, E.;
Wollack, E. J.;
U-Yen, K.;
Cao, N.;
Stevenson, T.;
Hsieh, W.;
Devlin, M.;
Dicker, S.;
Semisch, C.;
Irwin, K.
Submitted: 2006-09-19
The Primordial Anisotropy Polarization Pathfinder Array (PAPPA) is a
balloon-based instrument to measure the polarization of the cosmic microwave
background and search for the signal from gravity waves excited during an
inflationary epoch in the early universe. PAPPA will survey a 20 x 20 deg patch
at the North Celestial Pole using 32 pixels in 3 passbands centered at 89, 212,
and 302 GHz. Each pixel uses MEMS switches in a superconducting microstrip
transmission line to combine the phase modulation techniques used in radio
astronomy with the sensitivity of transition-edge superconducting bolometers.
Each switched circuit modulates the incident polarization on a single detector,
allowing nearly instantaneous characterization of the Stokes I, Q, and U
parameters. We describe the instrument design and status.