Normalized to: Steiger, H.
[1]
oai:arXiv.org:1912.02038 [pdf] - 2009595
Design and Status of JUNO
Submitted: 2019-12-04
The Jiangmen Underground Neutrino Observatory (JUNO) is a 20 kton
multi-purpose liquid scintillator detector currently being built in a dedicated
underground laboratory in Jiangmen (PR China). JUNO' s main physics goal is to
determine the neutrino mass ordering using electron anti-neutrinos from two
nuclear power plants at a baseline of about 53 km. JUNO aims for an
unprecedented energy resolution of 3% at 1 MeV for the central detector, with
which the mass ordering can be measured with 3 - 4 $\sigma$ significance within
six years of operation. Most neutrino oscillation parameters in the solar and
atmospheric sectors can also be measured with an accuracy of 1% or better.
Furthermore, being the largest liquid scintillator detector of its kind, JUNO
will monitor the neutrino sky continuously for contributing to neutrino and
multi-messenger astronomy. JUNO' s design as well as the status of its
construction will be presented, together with a short excursion into its rich
R&D program.
[2]
oai:arXiv.org:1802.08639 [pdf] - 1639827
A prototype detector for the CRESST-III low-mass dark matter search
Strauss, R.;
Angloher, G.;
Bauer, P.;
Defay, X.;
Erb, A.;
Feilitzsch, F. v.;
Iachellini, N. Ferreiro;
Hampf, R.;
Hauff, D.;
Kiefer, M.;
Lanfranchi, J. -C.;
Langenkämper, A.;
Mondragon, E.;
Münster, A.;
Oppenheimer, C.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Reindl, F.;
Rothe, J.;
Schönert, S.;
Seidel, W.;
Steiger, H.;
Stodolsky, L.;
Tanzke, A.;
Thi, H. H. Trinh;
Ulrich, A.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.;
Zöller, A.
Submitted: 2018-02-23
The CRESST-III experiment which is dedicated to low-mass dark matter search
uses scintillating CaWO$_4$ crystals operated as cryogenic particle detectors.
Background discrimination is achieved by exploiting the scintillating light
signal of CaWO$_4$ and by a novel active detector holder presented in this
paper. In a test setup above ground, a nuclear-recoil energy threshold of
$E_{th}=(190.6\pm5.2)$eV is reached with a 24g prototype detector, which
corresponds to an estimated threshold of $\sim$50eV when being operated in the
low-noise CRESST cryostat. This is the lowest threshold reported for direct
dark matter searches. For CRESST-III phase 1, ten such detector modules were
installed in the cryostat which have the potential to improve significantly the
sensitivity to scatterings of dark matter particles with masses down to
$\sim$0.1GeV/c$^2$.
[3]
oai:arXiv.org:1703.07152 [pdf] - 1648551
Low-Temperature Relative Reflectivity Measurements of Reflective and
Scintillating Foils used in Rare Event Searches
Langenkämper, A.;
Ulrich, A.;
Defay, X.;
Feilitzsch, F. v.;
Lanfranchi, J. -C.;
Mondragón, E.;
Münster, A.;
Oppenheimer, C.;
Potzel, W.;
Roth, S.;
Schönert, S.;
Steiger, H.;
Thi, H. H. Trinh;
Wawoczny, S.;
Willers, M.;
Zöller, A.
Submitted: 2017-03-21, last modified: 2017-12-20
In this work we investigate the reflectivity of highly reflective multilayer
polymer foils used in the CRESST experiment. The CRESST experiment searches
directly for dark matter via operating scintillating CaWO$_4$ crystals as
targets for elastic dark matter-nucleon scattering. In order to suppress
background events, the experiment employs the so-called phonon-light technique
which is based on the simultaneous measurement of the heat signal in the main
CaWO$_4$ target crystal and of the emitted scintillation light with a separate
cryogenic light detector. Both detectors are surrounded by a highly reflective
and scintillating multilayer polymer foil to increase the light collection
efficiency and to veto surface backgrounds. While this study is motivated by
the CRESST experiment, the results are also relevant for other rare event
searches using scintillating cryogenic bolometers in the field of the search of
dark matter and neutrinoless double beta decay ($0\nu\beta\beta$). In this work
a dedicated experiment has been set up to determine the relative reflectivity
at 300 K and 20 K of three multilayer foils ("VM2000", "VM2002", "Vikuiti")
produced by the company 3M. The intensity of a light beam reflected off the
foil is measured with a CCD camera. The ratio of the intensities at 300 K and
20 K corresponds to the relative reflectivity change. The measurements
performed in this work show no significant change in the reflectivity with
temperature for all foils studied.
[4]
oai:arXiv.org:1509.06266 [pdf] - 1378623
Cryogenic silicon detectors with implanted contacts for the detection of
visible photons using the Neganov-Luke Effect
Defay, X.;
Mondragon, E.;
Willers, M.;
Langenkamper, A.;
Lanfranchi, J. -C.;
Munstera, A.;
Zoller, A.;
Wawoczny, S.;
Steiger, H.;
Hitzler, F.;
Bruhn, C.;
Schonert, S.;
Potzel, W.;
Chapellier, M.
Submitted: 2015-09-21, last modified: 2016-01-28
There is a common need in astroparticle experiments such as direct dark
matter detection, 0{\nu}\b{eta}\b{eta} (double beta decay without emission of
neutrinos) and Coherent Neutrino Nucleus Scattering experiments for light
detectors with a very low energy threshold. By employing the Neganov-Luke
Effect, the thermal signal of particle interactions in a semiconductor absorber
operated at cryogenic temperatures, can be amplified by drifting the
photogenerated electrons and holes in an electric field. This technology is not
used in current experiments, in particular because of a reduction of the signal
amplitude with time which is due to trapping of the charges within the
absorber. We present here the first results of a novel type of Neganov-Luke
Effect detector with an electric field configuration designed to improve the
charge collection within the semiconductor.