sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Staszak, Nick

Normalized to: Staszak, N.

6 article(s) in total. 88 co-authors, from 1 to 5 common article(s). Median position in authors list is 11,0.

[1]  oai:arXiv.org:1805.10761  [pdf] - 1689889
Starbug fibre positioning robots: performance and reliability enhancements
Comments: 10 Pages
Submitted: 2018-05-28
Starbugs are miniature piezoelectric walking robots that can be operated in parallel to position many payloads like optical fibers across a telescopes focal plane. They consist of two concentric piezoelectric ceramic tubes that walk with micron step size. In addition to individual optical fibers, Starbugs have moved a payload of 0.75kg at several millimeters per second. The Australian Astronomical Observatory previously developed prototype devices and tested them in the laboratory. Now we are optimizing the Starbug design for production and deployment in the TAIPAN instrument, which will be capable of configuring 300 optical fibers over a six degree field-of-view on the UK Schmidt Telescope within a few minutes. The TAIPAN instrument will demonstrate the technology and capability for MANIFEST (Many Instrument Fiber-System) proposed for the Giant Magellan Telescope. Design is addressing: connector density and voltage limitations, mechanical reliability and construction repeatability, field plate residues and scratching, metrology stability, and facilitation of improved motion in all aspects of the design for later evaluation. Here we present the new design features of the AAO TAIPAN Starbug.
[2]  oai:arXiv.org:1608.03921  [pdf] - 1542702
Hector - a new massively multiplexed IFS instrument for the Anglo-Australian Telescope
Comments: Submitted for SPIE Astronomical Telescopes and Instrumentation 2016
Submitted: 2016-08-12
Hector will be the new massively-multiplexed integral field spectroscopy (IFS) instrument for the Anglo-Australian Telescope (AAT) in Australia and the next main dark-time instrument for the observatory. Based on the success of the SAMI instrument, which is undertaking a 3400-galaxy survey, the integral field unit (IFU) imaging fibre bundle (hexabundle) technology under-pinning SAMI is being improved to a new innovative design for Hector. The distribution of hexabundle angular sizes is matched to the galaxy survey properties in order to image 90% of galaxies out to 2 effective radii. 50-100 of these IFU imaging bundles will be positioned by 'starbug' robots across a new 3-degree field corrector top end to be purpose-built for the AAT. Many thousand fibres will then be fed into new replicable spectrographs. Fundamentally new science will be achieved compared to existing instruments due to Hector's wider field of view (3 degrees), high positioning efficiency using starbugs, higher spectroscopic resolution (R~3000-5500 from 3727-7761A, with a possible redder extension later) and large IFUs (up to 30 arcsec diameter with 61-217 fibre cores). A 100,000 galaxy IFS survey with Hector will decrypt how the accretion and merger history and large-scale environment made every galaxy different in its morphology and star formation history. The high resolution, particularly in the blue, will make Hector the only instrument to be able to measure higher-order kinematics for galaxies down to much lower velocity dispersion than in current large IFS galaxy surveys, opening up a wealth of new nearby galaxy science.
[3]  oai:arXiv.org:1509.00129  [pdf] - 1530302
First Light Results from the Hermes Spectrograph at the AAT
Comments: 22 pages, 28 figures. AAT, 2dF, HERMES
Submitted: 2015-08-31
The High Efficiency and Resolution Multi Element Spectrograph, HERMES, is a facility-class optical spectrograph for the Anglo-Australian Telescope (AAT). It is designed primarily for Galactic Archaeology, the first major attempt to create a detailed understanding of galaxy formation and evolution by studying the history of our own galaxy, the Milky Way. The goal of the GALAH survey is to reconstruct the mass assembly history of the Milky Way through a detailed chemical abundance study of one million stars. The spectrograph is based at the AAT and is fed by the existing 2dF robotic fiber positioning system. The spectrograph uses volume phase holographic gratings to achieve a spectral resolving power of 28,000 in standard mode and also provides a high-resolution mode ranging between 40,000 and 50,000 using a slit mask. The GALAH survey requires an SNR greater than 100 for a star brightness of V ?= 14 in an exposure time of one hour. The total spectral coverage of the four channels is about 100 nm between 370 and 1000 nm for up to 392 simultaneous targets within the 2-degree field of view. HERMES has been commissioned over three runs, during bright time in October, November, and December 2013, in parallel with the beginning of the GALAH pilot survey, which started in November 2013. We present the first-light results from the commissioning run and the beginning of the GALAH survey, including performance results such as throughput and resolution, as well as instrument reliability.
[4]  oai:arXiv.org:1407.6438  [pdf] - 1215881
PRAXIS: low thermal emission high efficiency OH suppressed fibre spectrograph
Comments: SPIE conference proceedings 9151
Submitted: 2014-07-23, last modified: 2014-07-29
PRAXIS is a second generation instrument that follows on from GNOSIS, which was the first instrument using fibre Bragg gratings for OH background suppression. The Bragg gratings reflect the NIR OH lines while being transparent to light between the lines. This gives a much higher signal-noise ratio at low resolution but also at higher resolutions by removing the scattered wings of the OH lines. The specifications call for high throughput and very low thermal and detector noise so that PRAXIS will remain sky noise limited. The optical train is made of fore-optics, an IFU, a fibre bundle, the Bragg grating unit, a second fibre bundle and a spectrograph. GNOSIS used the pre-existing IRIS2 spectrograph while PRAXIS will use a new spectrograph specifically designed for the fibre Bragg grating OH suppression and optimised for 1470 nm to 1700 nm (it can also be used in the 1090 nm to 1260 nm band by changing the grating and refocussing). This results in a significantly higher transmission due to high efficiency coatings, a VPH grating at low incident angle and low absorption glasses. The detector noise will also be lower. Throughout the PRAXIS design special care was taken at every step along the optical path to reduce thermal emission or stop it leaking into the system. This made the spectrograph design challenging because practical constraints required that the detector and the spectrograph enclosures be physically separate by air at ambient temperature. At present, the instrument uses the GNOSIS fibre Bragg grating OH suppression unit. We intend to soon use a new OH suppression unit based on multicore fibre Bragg gratings which will allow increased field of view per fibre. Theoretical calculations show that the gain in interline sky background signal-noise ratio over GNOSIS may very well be as high as 9 with the GNOSIS OH suppression unit and 17 with the multicore fibre OH suppression unit.
[5]  oai:arXiv.org:1301.0670  [pdf] - 610414
CYCLOPS2: the fibre image slicer upgrade for the UCLES high resolution spectrograph
Comments: 9 pages, 6 figures, published in Proc. SPIE 8446
Submitted: 2013-01-03
CYCLOPS2 is an upgrade for the UCLES high resolution spectrograph on the Anglo-Australian Telescope, scheduled for commissioning in semester 2012A. By replacing the 5 mirror Coud\'e train with a Cassegrain mounted fibre-based image slicer CYCLOPS2 simultaneously provides improved throughput, reduced aperture losses and increased spectral resolution. Sixteen optical fibres collect light from a 5.0 arcsecond^2 area of sky and reformat it into the equivalent of a 0.6 arcsecond wide slit, delivering a spectral resolution of R = 70000 and up to twice as much flux as the standard 1 arcsecond slit of the Coud\'e train. CYCLOPS2 also adds support for simultaneous ThAr wavelength calibration via a dedicated fibre. CYCLOPS2 consists of three main components, the fore-optics unit, fibre bundle and slit unit. The fore optics unit incorporates magnification optics and a lenslet array and is designed to mount to the CURE Cassegrain instrument interface, which provides acquisition, guiding and calibration facilities. The fibre bundle transports the light from the Cassegrain focus to the UCLES spectrograph at Coud\'e and also includes a fibre mode scrambler. The slit unit consists of the fibre slit and relay optics to project an image of the slit onto the entrance aperture of the UCLES spectrograph. CYCLOPS2 builds on experience with the first generation CYCLOPS fibre system, which we also describe in this paper. We present the science case for an image slicing fibre feed for echelle spectroscopy and describe the design of CYCLOPS and CYCLOPS2.
[6]  oai:arXiv.org:1207.7011  [pdf] - 1125184
'MOHAWK' : a 4000-fiber positioner for DESpec
Comments: 10 pages, to appear in Proc. SPIE 8446
Submitted: 2012-07-30, last modified: 2012-07-31
We present a concept for a 4000-fibre positioner for DESpec, based on the Echidna 'tilting spine' technology. The DESpec focal plane is 450mm across and curved, and the required pitch is ~6.75mm. The size, number of fibers and curvature are all comparable with various concept studies for similar instruments already undertaken at the AAO, but present new challenges in combination. A simple, low-cost, and highly modular design is presented, consisting of identical modules populated by identical spines. No show-stopping issues in accommodating either the curvature or the smaller pitch have been identified, and the actuators consist largely of off-the-shelf components. The actuators have been prototyped at AAO, and allow reconfiguration times of ~15s to reach position errors 7 microns or less. Straightforward designs for metrology, acquisition, and guiding are also proposed. The throughput losses of the entire positioner system are estimated to be ~15%, of which 6.3% is attributable to the tilting-spine technology.