Normalized to: Stanwix, P.
[1]
oai:arXiv.org:gr-qc/0609072 [pdf] - 112320
Improved test of Lorentz Invariance in Electrodynamics using Rotating
Cryogenic Sapphire Oscillators
Submitted: 2006-09-19, last modified: 2006-10-03
We present new results from our test of Lorentz invariance, which compares
two orthogonal cryogenic sapphire microwave oscillators rotating in the lab. We
have now acquired over 1 year of data, allowing us to avoid the short data set
approximation (less than 1 year) that assumes no cancelation occurs between the
$\tilde{\kappa}_{e-}$ and $\tilde{\kappa}_{o+}$ parameters from the photon
sector of the standard model extension. Thus, we are able to place independent
limits on all eight $\tilde{\kappa}_{e-}$ and $\tilde{\kappa}_{o+}$ parameters.
Our results represents up to a factor of 10 improvement over previous non
rotating measurements (which independently constrained 7 parameters), and is a
slight improvement (except for $\tilde{\kappa}_{e-}^{ZZ}$) over results from
previous rotating experiments that assumed the short data set approximation.
Also, an analysis in the Robertson-Mansouri-Sexl framework allows us to place a
new limit on the isotropy parameter $P_{MM}=\delta-\beta+{1/2}$ of
$9.4(8.1)\times10^{-11}$, an improvement of a factor of 2.
[2]
oai:arXiv.org:hep-ph/0506200 [pdf] - 265407
Rotating Resonator-Oscillator Experiments to Test Lorentz Invariance in
Electrodynamics
Submitted: 2005-06-21, last modified: 2005-10-17
In this work we outline the two most commonly used test theories (RMS and
SME) for testing Local Lorentz Invariance (LLI) of the photon. Then we develop
the general framework of applying these test theories to resonator experiments
with an emphasis on rotating experiments in the laboratory. We compare the
inherent sensitivity factors of common experiments and propose some new
configurations. Finally we apply the test theories to the rotating cryogenic
experiment at the University of Western Australia, which recently set new
limits in both the RMS and SME frameworks [hep-ph/0506074].
[3]
oai:arXiv.org:hep-ph/0506074 [pdf] - 115055
Test of Lorentz Invariance in Electrodynamics Using Rotating Cryogenic
Sapphire Microwave Oscillators
Submitted: 2005-06-07, last modified: 2005-07-21
We present the first results from a rotating Michelson-Morley experiment that
uses two orthogonally orientated cryogenic sapphire resonator-oscillators
operating in whispering gallery modes near 10 GHz. The experiment is used to
test for violations of Lorentz Invariance in the frame-work of the photon
sector of the Standard Model Extension (SME), as well as the isotropy term of
the Robertson-Mansouri-Sexl (RMS) framework. In the SME we set a new bound on
the previously unmeasured $\tilde{\kappa}_{e-}^{ZZ}$ component of
$2.1(5.7)\times10^{-14}$, and set more stringent bounds by up to a factor of 7
on seven other components. In the RMS a more stringent bound of
$-0.9(2.0)\times 10^{-10}$ on the isotropy parameter, $P_{MM}=\delta - \beta +
{1/2}$ is set, which is more than a factor of 7 improvement. More detailed
description of the experiment and calculations can be found in: hep-ph/0506200