Normalized to: Sreedhar, Y.
[1]
oai:arXiv.org:1705.03715 [pdf] - 1583290
In-orbit Calibrations of the Ultra-Violet Imaging Telescope
Tandon, S. N.;
Subramaniam, Annapurni;
Girish, V.;
Postma, J.;
Sankarasubramanian, K.;
Sriram, S.;
Stalin, C. S.;
Mondal, C.;
Joseph, S. Sahu P.;
Hutchings, J.;
Ghosh, S. K.;
Barve, I. V.;
George, K.;
Kamath, P. U.;
Kathiravan, S.;
Kumar, A.;
Lancelot, J. P.;
Leahy, D.;
Mahesh, P. K.;
Mohan, R.;
Nagabhushana, S.;
Pati, A. K.;
Rao, N. Kameswara;
Sreedhar, Y. H.;
Sreekumar, P.
Submitted: 2017-05-10, last modified: 2017-08-05
The Ultra-Violet Imaging Telescope (UVIT) is one of the payloads in ASTROSAT,
the first Indian Space Observatory. The UVIT instrument has two 375mm
telescopes: one for the far-ultraviolet (FUV) channel (1300--1800\AA), and the
other for the near-ultraviolet (NUV) channel (2000--3000\AA) and the visible
(VIS) channel (3200--5500\AA). UVIT is primarily designed for simultaneous
imaging in the two ultraviolet channels with spatial resolution better than 1.8
arcsec, along with provision for slit-less spectroscopy in the NUV and FUV
channels.The results of in-orbit calibrations of UVIT are presented in this
paper.
[2]
oai:arXiv.org:1612.00612 [pdf] - 1580790
In-orbit Performance of UVIT and First Results
Tandon, S. N.;
Hutchings, J. B.;
Ghosh, S. K.;
Subramaniam, A.;
Koshy, G.;
Girish, V.;
Kamath, P. U.;
Kathiravan, s.;
Kumar, A.;
Lancelot, J. P.;
Mahesh, P. K.;
Mohan, R.;
Murthy, J.;
Nagabhushana, S.;
A, A. K. Pati;
Postma, J.;
Rao, N. Kameswara;
Sankarasubramanian, K.;
Sreekumar, P.;
Sriram, S.;
Stalin, C. S.;
Sutaria, F.;
Sreedhar, Y. H.;
Barve, I. V.;
Mondal, C.;
Sahu, S.
Submitted: 2016-12-02
The performance of the ultraviolet telescope (UVIT) on-board ASTROSAT is
reported. The performance in orbit is also compared with estimates made from
the calibrations done on the ground. The sensitivity is found to be within ~15%
of the estimates, and the spatial resolution in the NUV is found to exceed
significantly the design value of 1.8 arcsec and it is marginally better in the
FUV. Images obtained from UVIT are presented to illustrate the details revealed
by the high spatial resolution. The potential of multi-band observations in the
ultraviolet with high spatial resolution is illustrated by some results.
[3]
oai:arXiv.org:1608.01073 [pdf] - 1521281
In-orbit Performance of UVIT on ASTROSAT
Subramaniam, Annapurni;
Tandon, Shyam N.;
Hutchings, John;
Ghosh, Swarna K.;
George, Koshy;
Girish, V.;
Kamath, P. U.;
Kathiravan, S.;
Kumar, Amit;
Lancelot, J. Paul;
Mahesh, P. K.;
Mohan, Rekhesh;
Murthy, Jayant;
Nagabhushana, S.;
Pati, Ashok K.;
Postma, Joe;
Rao, N. Kameswara;
Sankarasubramanian, Kasiviswanathan;
Sreekumar, P.;
Sriram, S.;
Stalin, Chelliah S.;
Sutaria, Firoza;
Sreedhar, Yuvraj Harsha;
Barve, Indrajit V.;
Mondal, Chayan;
Sahu, Snehalata
Submitted: 2016-08-03
We present the in-orbit performance and the first results from the
ultra-violet Imaging telescope (UVIT) on ASTROSAT. UVIT consists of two
identical 38cm coaligned telescopes, one for the FUV channel (130-180nm) and
the other for the NUV (200-300nm) and VIS (320-550nm) channels, with a field of
view of 28 $arcmin$. The FUV and the NUV detectors are operated in the high
gain photon counting mode whereas the VIS detector is operated in the low gain
integration mode. The FUV and NUV channels have filters and gratings, whereas
the VIS channel has filters. The ASTROSAT was launched on 28th September 2015.
The performance verification of UVIT was carried out after the opening of the
UVIT doors on 30th November 2015, till the end of March 2016 within the
allotted time of 50 days for calibration. All the on-board systems were found
to be working satisfactorily. During the PV phase, the UVIT observed several
calibration sources to characterise the instrument and a few objects to
demonstrate the capability of the UVIT. The resolution of the UVIT was found to
be about 1.4 - 1.7 $arcsec$ in the FUV and NUV. The sensitivity in various
filters were calibrated using standard stars (white dwarfs), to estimate the
zero-point magnitudes as well as the flux conversion factor. The gratings were
also calibrated to estimate their resolution as well as effective area. The
sensitivity of the filters were found to be reduced up to 15\% with respect to
the ground calibrations. The sensitivity variation is monitored on a monthly
basis. UVIT is all set to roll out science results with its imaging capability
with good resolution and large field of view, capability to sample the UV
spectral region using different filters and capability to perform variability
studies in the UV.
[4]
oai:arXiv.org:1410.2711 [pdf] - 880290
Red population of Abell 1314 : A Rest-Frame Narrowband Photometric
Evolutionary Analysis
Submitted: 2014-10-10
Red sequence galaxies form with an intense burst of star formation in the
early universe to evolve passively into massive, metal rich, old galaxies at z
~ 0. But Abell 1314 (z=0.034) is found to host almost all red sequence galaxy
members -- identified using the mz index, classified using the Principle
Component Analysis technique and SDSS colour correlations -- some of which show
properties of low-mass, star forming, and metal rich galaxies. The variably
spread Intra-Cluster Medium (ICM) near the core forms a vital part in
influencing the evolution of these members. To study their evolution, I
correlated different parameters of the rest-frame narrowband photometry and the
derived luminosity-weighted mean Single Stellar Population model ages and
metallicities.
The study finds the member galaxies evolve differently in three different
sections of the cluster: 1. the region of < 200 kpc hosts passively evolving
old, massive systems which accumulate mass by dry, minor mergers, 2. the zone
between 200-500 kpc shows stripped systems (or in the process of being gas
stripped) by ram pressure with moderate star formation history, 3. the outer
regions (> 500 kpc) show low-mass red objects with blue, star forming
Butcher-Oemler galaxy like colours. This sort of environmental condition is
known to harbour hybrid systems, like, the pseudo bulges, blue sequence E/S0
and Butcher-Oemler like satellite cluster galaxies. Overall, the cluster is
found to be poor, quiescent with galaxies to have formed by the monolithic
structure formation in the early universe and are now evolving with mergers and
gas stripping processes by ram pressure.
[5]
oai:arXiv.org:1401.2263 [pdf] - 1705115
Comparative studies of Population Synthesis Models in the frame work of
modified Str\"{o}mgren filters
Submitted: 2014-01-10
Evolutionary models form a vital part of stellar population research to
understand their evolution, but despite their long history of development, they
often misrepresent and misinterpret the properties of stellar population
observed through broadband and spectroscopic measurements. With the growing
numbers of these synthesis models, model comparison becomes an important
analysis to choose a suitable model for upgrade. Along with the model
comparison, we reinvestigate the technique of modified Str\"omgren photometry
to measure reliable parameter-sensitive colours and estimate precise model ages
and metallicities. The assessment of Rakos/Schulz models with GALEV and
Worthey's Lick/IDS model find smaller colour variation: \Delta(uz-vz) $\leq$
0.056, \Delta(bz-yz) $\leq$ -0.05 and \Delta(vz-yz) $\leq$ 0.061. The study
conveys a good agreement of GALEV models with the modified Str\"omgren colours
but with poor UV model predictions with the observed globular cluster data,
while the spectroscopic models perform badly due to the use of older isochrone
and stellar spectral libraries with inaccurate/insufficient knowledge of
various stellar phases and their treatment. Overall, the assessment finds
modified Str\"omgren photometry well suited to study different types stellar
populations by mitigating the effects of the age-metallicity degeneracy.
[6]
oai:arXiv.org:1201.2373 [pdf] - 462804
Ages and Metallicities of Cluster Galaxies in A779 using Modified
Str\"omgren Photometry
Submitted: 2012-01-11
In the quest for the formation and evolution of galaxy clusters, Rakos and
co-workers introduced a spectrophotometric method using the modified
Str\"omgren photometry. But with the considerable debate toward the project's
abilities, we re-introduce the system after a thorough testing of repeatability
of colors and reproducibility of the ages and metallicities for six common
galaxies in the three A779 data sets. A fair agreement has been found between
the modified Str\"omgren and Str\"omgren filter systems to produce similar
colors (with the precision of 0.09 mag in (uz-vz), 0.02 mag in (bz-yz), and
0.03 mag in (vz-vz)), ages and metallicities (with the uncertainty of 0.36 Gyr
and 0.04 dex from the PCA and 0.44 Gyr and 0.2 dex using the GALEV models). We
infer that the technique is able to relieve the age-metallicity degeneracy by
separating the age effects from the metallicity effects, but still unable to
completely break. We further extend this paper to re-study the evolution of
galaxies in the low mass, dynamically poor A779 cluster by correlating the
luminosity (mass), density, radial distance with the estimated age,
metallicity, and the star formation history. Our results distinctly show the
bimodality of the young, low-mass, metal-poor population with the mean age of
6.7 Gyr (\pm 0.5 Gyr) and the old, high-mass, metal-rich galaxies with the mean
age of 9 Gyr (\pm 0.5 Gyr). The method also observes the color evolution of the
blue cluster galaxies to red, and the downsizing phenomenon. Our analysis shows
that the modified Str\"omgren photometry is very well suited for studying low-
and intermediate-z clusters, as it is capable of observing deeper with better
spatial resolution at spectroscopic redshift limits, and the narrowband filters
estimate the age and metallicity with lesser uncertainties compared to other
methods that study stellar population scenarios.