Normalized to: Spinelli, S.
[1]
oai:arXiv.org:2001.10272 [pdf] - 2065386
QUBIC: the Q & U Bolometric Interferometer for Cosmology
Battistelli, E. S.;
Ade, P.;
Alberro, J. G.;
Almela, A.;
Amico, G.;
Arnaldi, L. H.;
Auguste, D.;
Aumont, J.;
Azzoni, S.;
Banfi, S.;
Battaglia, P.;
Baù, A.;
Bèlier, B.;
Bennett, D.;
Bergè, L.;
Bernard, J. -Ph.;
Bersanelli, M.;
Bigot-Sazy, M. -A.;
Bleurvacq, N.;
Bonaparte, J.;
Bonis, J.;
Bottani, A.;
Bunn, E.;
Burke, D.;
Buzi, D.;
Buzzelli, A.;
Cavaliere, F.;
Chanial, P.;
Chapron, C.;
Charlassier, R.;
Columbro, F.;
Coppi, G.;
Coppolecchia, A.;
D'Alessandro, G.;
de Bernardis, P.;
De Gasperis, G.;
De Leo, M.;
De Petris, M.;
Dheilly, S.;
Di Donato, A.;
Dumoulin, L.;
Etchegoyen, A.;
Fasciszewski, A.;
Ferreyro, L. P.;
Fracchia, D.;
Franceschet, C.;
Lerena, M. M. Gamboa;
Ganga, K.;
Garcìa, B.;
Redondo, M. E. Garcìa;
Gaspard, M.;
Gault, A.;
Gayer, D.;
Gervasi, M.;
Giard, M.;
Gilles, V.;
Giraud-Heraud, Y.;
Berisso, M. Gòmez;
Gonzàlez, M.;
Gradziel, M.;
Grandsire, L.;
Hamilton, J. -Ch.;
Harari, D.;
Haynes, V.;
Henrot-Versillè, S.;
Hoang, D. T.;
Incardona, F.;
Jules, E.;
Kaplan, J.;
Korotkov, A.;
Kristukat, C.;
Lamagna, L.;
Loucatos, S.;
Louis, T.;
Luterstein, R.;
Maffei, B.;
Marnieros, S.;
Marty, W.;
Masi, S.;
Mattei, A.;
May, A.;
McCulloch, M.;
Medina, M. C.;
Mele, L.;
Melhuish, S.;
Mennella, A.;
Montier, L.;
Mousset, L.;
Mundo, L. M.;
Murphy, J. A.;
Murphy, J. D.;
Nati, F.;
Olivieri, E.;
Oriol, C.;
O'Sullivan, C.;
Paiella, A.;
Pajot, F.;
Passerini, A.;
Pastoriza, H.;
Pelosi, A.;
Perbost, C.;
Perciballi, M.;
Pezzotta, F.;
Piacentini, F.;
Piat, M.;
Piccirillo, L.;
Pisano, G.;
Platino, M.;
Polenta, G.;
Prèle, D.;
Puddu, R.;
Rambaud, D.;
Ringegni, P.;
Romero, G. E.;
Salatino, M.;
Salum, J. M.;
Schillaci, A.;
Scòccola, C.;
Scully, S.;
Spinelli, S.;
Stankowiak, G.;
Stolpovskiy, M.;
Suarez, F.;
Tartari, A.;
Thermeau, J. -P.;
Timbie, P.;
Tomasi, M.;
Torchinsky, S.;
Tristram, M.;
Tucker, C.;
Tucker, G.;
Vanneste, S.;
Viganò, D.;
Vittorio, N.;
Voisin, F.;
Watson, B.;
Wicek, F.;
Zannoni, M.;
Zullo, A.
Submitted: 2020-01-28
The Q & U Bolometric Interferometer for Cosmology, QUBIC, is an innovative
experiment designed to measure the polarization of the Cosmic Microwave
Background and in particular the signature left therein by the inflationary
expansion of the Universe. The expected signal is extremely faint, thus extreme
sensitivity and systematic control are necessary in order to attempt this
measurement. QUBIC addresses these requirements using an innovative approach
combining the sensitivity of Transition Edge Sensor cryogenic bolometers, with
the deep control of systematics characteristic of interferometers. This makes
QUBIC unique with respect to others classical imagers experiments devoted to
the CMB polarization. In this contribution we report a description of the QUBIC
instrument including recent achievements and the demonstration of the
bolometric interferometry performed in lab. QUBIC will be deployed at the
observation site in Alto Chorrillos, in Argentina at the end of 2019.
[2]
oai:arXiv.org:1911.12418 [pdf] - 2011325
QUBIC: using NbSi TESs with a bolometric interferometer to characterize
the polarisation of the CMB
Piat, M.;
Bélier, B.;
Bergé, L.;
Bleurvacq, N.;
Chapron, C.;
Dheilly, S.;
Dumoulin, L.;
González, M.;
Grandsire, L.;
Hamilton, J. -Ch.;
Henrot-Versillé, S.;
Hoang, D. T.;
Marnieros, S.;
Marty, W.;
Montier, L.;
Olivieri, E.;
Oriol, C.;
Perbost, C.;
Prêle, D.;
Rambaud, D.;
Salatino, M.;
Stankowiak, G.;
Thermeau, J. -P.;
Torchinsky, S.;
Voisin, F.;
Ade, P.;
Alberro, J. G.;
Almela, A.;
Amico, G.;
Arnaldi, L. H.;
Auguste, D.;
Aumont, J.;
Azzoni, S.;
Banfi, S.;
Battaglia, P.;
Battistelli, E. S.;
Baù, A.;
Bennett, D.;
Bernard, J. -Ph.;
Bersanelli, M.;
Bigot-Sazy, M. -A.;
Bonaparte, J.;
Bonis, J.;
Bottani, A.;
Bunn, E.;
Burke, D.;
Buzi, D.;
Buzzelli, A.;
Cavaliere, F.;
Chanial, P.;
Charlassier, R.;
Columbro, F.;
Coppi, G.;
Coppolecchia, A.;
D'Alessandro, G.;
de Bernardis, P.;
De Gasperis, G.;
De Leo, M.;
De Petris, M.;
Di Donato, A.;
Etchegoyen, A.;
Fasciszewski, A.;
Ferreyro, L. P.;
Fracchia, D.;
Franceschet, C.;
Lerena, M. M. Gamboa;
Ganga, K.;
García, B.;
Redondo, M. E. García;
Gaspard, M.;
Gault, A.;
Gayer, D.;
Gervasi, M.;
Giard, M.;
Gilles, V.;
Giraud-Heraud, Y.;
Berisso, M. Gómez;
Gradziel, M.;
Harari, D.;
Haynes, V.;
Incardona, F.;
Jules, E.;
Kaplan, J.;
Korotkov, A.;
Kristukat, C.;
Lamagna, L.;
Loucatos, S.;
Louis, T.;
Luterstein, R.;
Maffei, B.;
Masi, S.;
Mattei, A.;
May, A.;
McCulloch, M.;
Medina, M. C.;
Mele, L.;
Melhuish, S.;
Mennella, A.;
Mousset, L.;
Mundo, L. M.;
Murphy, J. A.;
Murphy, J. D.;
Nati, F.;
O'Sullivan, C.;
Paiella, A.;
Pajot, F.;
Passerini, A.;
Pastoriza, H.;
Pelosi, A.;
Perciballi, M.;
Pezzotta, F.;
Piacentini, F.;
Piccirillo, L.;
Pisano, G.;
Platino, M.;
Polenta, G.;
Puddu, R.;
Ringegni, P.;
Romero, G. E.;
Salum, J. M.;
Schillaci, A.;
Scóccola, C.;
Scully, S.;
Spinelli, S.;
Stolpovskiy, M.;
Suarez, F.;
Tartari, A.;
Timbie, P.;
Tomasi, M.;
Tucker, C.;
Tucker, G.;
Vanneste, S.;
Viganò, D.;
Vittorio, N.;
Watson, B.;
Wicek, F.;
Zannoni, M.;
Zullo, A.
Submitted: 2019-11-27, last modified: 2019-12-09
QUBIC (Q \& U Bolometric Interferometer for Cosmology) is an international
ground-based experiment dedicated in the measurement of the polarized
fluctuations of the Cosmic Microwave Background (CMB). It is based on
bolometric interferometry, an original detection technique which combine the
immunity to systematic effects of an interferometer with the sensitivity of low
temperature incoherent detectors. QUBIC will be deployed in Argentina, at the
Alto Chorrillos mountain site near San Antonio de los Cobres, in the Salta
province.
The QUBIC detection chain consists in 2048 NbSi Transition Edge Sensors
(TESs) cooled to 350mK.The voltage-biased TESs are read out with Time Domain
Multiplexing based on Superconducting QUantum Interference Devices (SQUIDs) at
1 K and a novel SiGe Application-Specific Integrated Circuit (ASIC) at 60 K
allowing to reach an unprecedented multiplexing (MUX) factor equal to 128.
The QUBIC experiment is currently being characterized in the lab with a
reduced number of detectors before upgrading to the full instrument. I will
present the last results of this characterization phase with a focus on the
detectors and readout system.
[3]
oai:arXiv.org:1812.00785 [pdf] - 1820173
QUBIC: Exploring the primordial Universe with the Q\&U Bolometric
Interferometer
Mennella, Aniello;
Ade, Peter;
Amico, Giorgio;
Auguste, Didier;
Aumont, Jonathan;
Banfi, Stefano;
Barbaràn, Gustavo;
Battaglia, Paola;
Battistelli, Elia;
Baù, Alessandro;
Bélier, Benoit;
Bennett, David G.;
Bergé, Laurent;
Bernard, Jean Philippe;
Bersanelli, Marco;
Sazy, Marie Anne Bigot;
Bleurvacq, Nathat;
Bonaparte, Juan;
Bonis, Julien;
Bunn, Emory F.;
Burke, David;
Buzi, Daniele;
Buzzelli, Alessandro;
Cavaliere, Francesco;
Chanial, Pierre;
Chapron, Claude;
Charlassier, Romain;
Columbro, Fabio;
Coppi, Gabriele;
Coppolecchia, Alessandro;
D'Agostino, Rocco;
D'Alessandro, Giuseppe;
De Bernardis, Paolo;
De Gasperis, Giancarlo;
De Leo, Michele;
De Petris, Marco;
Di Donato, Andres;
Dumoulin, Louis;
Etchegoyen, Alberto;
Fasciszewski, Adrián;
Franceschet, Cristian;
Lerena, Martin Miguel Gamboa;
Garcia, Beatriz;
Garrido, Xavier;
Gaspard, Michel;
Gault, Amanda;
Gayer, Donnacha;
Gervasi, Massimo;
Giard, Martin;
Héraud, Yannick Giraud;
Berisso, Mariano Gómez;
González, Manuel;
Gradziel, Marcin;
Grandsire, Laurent;
Guerard, Eric;
Hamilton, Jean Christophe;
Harari, Diego;
Haynes, Vic;
Versillé, Sophie Henrot;
Hoang, Duc Thuong;
Holtzer, Nicolas;
Incardona, Federico;
Jules, Eric;
Kaplan, Jean;
Korotkov, Andrei;
Kristukat, Christian;
Lamagna, Luca;
Loucatos, Soutiris;
Lowitz, Amy;
Lukovic, Vladimir;
Thibault, Louis;
Luterstein, Raùl Horacio;
Maffei, Bruno;
Marnieros, Stefanos;
Masi, Silvia;
Mattei, Angelo;
May, Andrew;
McCulloch, Mark;
Medina, Maria C.;
Mele, Lorenzo;
Melhuish, Simon J.;
Montier, Ludovic;
Mousset, Louise;
Mundo, Luis Mariano;
Murphy, John Anthony;
Murphy, James;
O'Sullivan, Creidhe;
Olivieri, Emiliano;
Paiella, Alessandro;
Pajot, Francois;
Passerini, Andrea;
Pastoriza, Hernan;
Pelosi, Alessandro;
Perbost, Camille;
Perciballi, Maurizio;
Pezzotta, Federico;
Piacentini, Francesco;
Piat, Michel;
Piccirillo, Lucio;
Pisano, Giampaolo;
Polenta, Gianluca;
Prêle, Damien;
Puddu, Roberto;
Rambaud, Damien;
Ringegni, Pablo;
Romero, Gustavo E.;
Salatino, Maria;
Schillaci, Alessandro;
Scóccola, Claudia G.;
Scully, Stephen P.;
Spinelli, Sebastiano;
Stolpovskiy, Michail;
Suarez, Federico;
Stankowiak, Guillaume;
Tartari, Andrea;
Thermeau, Jean Pierre;
Timbie, Peter;
Tomasi, Maurizio;
Torchinsky, Steve A.;
Tristram, Mathieu;
Tucker, Gregory S.;
Tucker, Carole E.;
Vanneste, Sylvain;
Viganò, Daniele;
Vittorio, Nicola;
Voisin, Fabrice;
Watson, Robert;
Wicek, Francois;
Zannoni, Mario;
Zullo, Antonio
Submitted: 2018-11-30, last modified: 2019-01-23
In this paper we describe QUBIC, an experiment that will observe the
polarized microwave sky with a novel approach, which combines the sensitivity
of state-of-the art bolometric detectors with the systematic effects control
typical of interferometers. QUBIC unique features are the so-called
"self-calibration", a technique that allows us to clean the measured data from
instrumental effects, and its spectral imaging power, i.e. the ability to
separate the signal in various sub-bands within each frequency band. QUBIC will
observe the sky in two main frequency bands: 150 GHz and 220 GHz. A
technological demonstrator is currently under testing and will be deployed in
Argentina during 2019, while the final instrument is expected to be installed
during 2020.
[4]
oai:arXiv.org:1811.02296 [pdf] - 1779826
Thermal architecture for the QUBIC cryogenic receiver
May, A. J.;
Chapron, C.;
Coppi, G.;
D'Alessandro, G.;
de Bernardis, P.;
Masi, S.;
Melhuish, S.;
Piat, M.;
Piccirillo, L.;
Schillaci, A.;
Thermeau, J. -P.;
Ade, P.;
Amico, G.;
Auguste, D.;
Aumont, J.;
Banfi, S.;
Barbara, G.;
Battaglia, P.;
Battistelli, E.;
Bau, A.;
Belier, B.;
Bennett, D.;
Berge, L.;
Bernard, J. -Ph.;
Bersanelli, M.;
Bigot-Sazy, M. -A.;
Bleurvacq, N.;
Bonaparte, J.;
Bonis, J.;
Bordier, G.;
Breelle, E.;
Bunn, E.;
Burke, D.;
Buzi, D.;
Buzzelli, A.;
Cavaliere, F.;
Chanial, P.;
Charlassier, R.;
Columbro, F.;
Coppolecchia, A.;
Couchot, F.;
D'Agostino, R.;
De Gasperis, G.;
De Leo, M.;
De Petris, M.;
Di Donato, A.;
Dumoulin, L.;
Etchegoyen, A.;
Fasciszewski, A.;
Franceschet, C.;
Lerena, M. M. Gamboa;
Garcia, B.;
Garrido, X.;
Gaspard, M.;
Gault, A.;
Gayer, D.;
Gervasi, M.;
Giard, M.;
Giraud-Heraud, Y.;
Berisso, M. Gomez;
Gonzalez, M.;
Gradziel, M.;
Grandsire, L.;
Guerrard, E.;
Hamilton, J. -Ch.;
Harari, D.;
Haynes, V.;
Henrot-Versille, S.;
Hoang, D. T.;
Incardona, F.;
Jules, E.;
Kaplan, J.;
Korotkov, A.;
Kristukat, C.;
Lamagna, L.;
Loucatos, S.;
Louis, T.;
Lowitz, A.;
Lukovic, V.;
Luterstein, R.;
Maffei, B.;
Marnieros, S.;
Mattei, A.;
McCulloch, M. A.;
Medina, M. C.;
Mele, L.;
Mennella, A.;
Montier, L.;
Mundo, L. M.;
Murphy, J. A.;
Murphy, J. D.;
O'Sullivan, C.;
Olivieri, E.;
Paiella, A.;
Pajot, F.;
Passerini, A.;
Pastoriza, H.;
Pelosi, A.;
Perbost, C.;
Perdereau, O.;
Pezzotta, F.;
Piacentini, F.;
Pisano, G.;
Polenta, G.;
Prele, D.;
Puddu, R.;
Rambaud, D.;
Ringegni, P.;
Romero, G. E.;
Salatino, M.;
Scoccola, C. G.;
Scully, S.;
Spinelli, S.;
Stolpovskiy, M.;
Suarez, F.;
Tartari, A.;
Timbie, P.;
Torchinsky, S. A.;
Tristram, M.;
Truongcanh, V.;
Tucker, C.;
Tucker, G.;
Vanneste, S.;
Vigano, D.;
Vittorio, N.;
Voisin, F.;
Watson, B.;
Wicek, F.;
Zannoni, M.;
Zullo, A.
Submitted: 2018-11-06
QUBIC, the QU Bolometric Interferometer for Cosmology, is a novel forthcoming
instrument to measure the B-mode polarization anisotropy of the Cosmic
Microwave Background. The detection of the B-mode signal will be extremely
challenging; QUBIC has been designed to address this with a novel approach,
namely bolometric interferometry. The receiver cryostat is exceptionally large
and cools complex optical and detector stages to 40 K, 4 K, 1 K and 350 mK
using two pulse tube coolers, a novel 4He sorption cooler and a double-stage
3He/4He sorption cooler. We discuss the thermal and mechanical design of the
cryostat, modelling and thermal analysis, and laboratory cryogenic testing.
[5]
oai:arXiv.org:1206.0481 [pdf] - 520364
A template of atmospheric molecular oxygen circularly polarized emission
for CMB experiments
Submitted: 2012-06-03
We compute the polarized signal from atmospheric molecular oxygen due to
Zeeman effect in the Earth magnetic field for various sites suitable for CMB
measurements such as South Pole, Dome C (Antarctica) and Atacama desert
(Chile). We present maps of this signal for those sites and show their typical
elevation and azimuth dependencies. We find a typical circularly polarized
signal (V Stokes parameter) level of 50 - 300 \mu K at 90 GHz when looking at
the zenith; Atacama site shows the lowest emission while Dome C site presents
the lowest gradient in polarized brightness temperature (0.3 \mu K/deg at 90
GHz). The accuracy and robustness of the template are tested with respect to
actual knowledge of the Earth magnetic field, its variability and atmospheric
parameters.
[6]
oai:arXiv.org:1203.5615 [pdf] - 1117549
Intensity and polarization of the atmospheric emission at millimetric
wavelengths at Dome Concordia
Battistelli, E. S.;
Amico, G.;
Baù, A.;
Bergé, L.;
Bréelle, É.;
Charlassier, R.;
Collin, S.;
Cruciani, A.;
de Bernardis, P.;
Dufour, C.;
Dumoulin, L.;
Gervasi, M.;
Giard, M.;
Giordano, C.;
Giraud-Héraud, Y.;
Guglielmi, L.;
Hamilton, J. -C.;
Landé, J.;
Maffei, B.;
Maiello, M.;
Marnieros, S.;
Masi, S.;
Passerini, A.;
Piacentini, F.;
Piat, M.;
Piccirillo, L.;
Pisano, G.;
Polenta, G.;
Rosset, C.;
Salatino, M.;
Schillaci, A.;
Sordini, R.;
Spinelli, S.;
Tartari, A.;
Zannoni, M.
Submitted: 2012-03-26, last modified: 2012-04-20
Atmospheric emission is a dominant source of disturbance in ground-based
astronomy at mm wavelengths. The Antarctic plateau is recognized to be an ideal
site for mm and sub-mm observations, and the French/Italian base of Dome C is
among the best sites on Earth for these observations. In this paper we present
measurements, performed using the BRAIN-pathfinder experiment, at Dome C of the
atmospheric emission in intensity and polarization at 150GHz, one of the best
observational frequencies for CMB observations when considering cosmic signal
intensity, atmospheric transmission, detectors sensitivity, and foreground
removal. Careful characterization of the air-mass synchronous emission has been
performed, acquiring more that 380 elevation scans (i.e. "skydip") during the
third BRAIN-pathfinder summer campaign in December 2009/January 2010. The
extremely high transparency of the Antarctic atmosphere over Dome Concordia is
proven by the very low measured optical depth: <tau_I>=0.050 \pm 0.003 \pm
0.011 where the first error is statistical and the second is systematic error.
Mid term stability, over the summer campaign, of the atmosphere emission has
also been studied. Adapting the radiative transfer atmosphere emission model
"am" to the particular conditions found at Dome C, we also infer the level of
the PWV content of the atmosphere, notoriously the main source of disturbance
in millimetric astronomy (<PWV>=0.77 +/- 0.06 + 0.15 - 0.12 mm). Upper limits
on the air-mass correlated polarized signal are also placed for the first time.
The degree of circular polarization of atmospheric emission is found to be
lower than 0.2% (95%CL), while the degree of linear polarization is found to be
lower than 0.1% (95%CL). These limits include signal-correlated instrumental
spurious polarization.
[7]
oai:arXiv.org:1103.0160 [pdf] - 1052417
A template of atmospheric O2 circularly polarized emission for CMB
experiments
Submitted: 2011-03-01
We compute the circularly polarized signal from atmospheric molecular oxygen.
Polarization of O2 rotational lines is caused by Zeeman effect in the Earth
magnetic field. We evaluate the circularly polarized emission for various sites
suitable for CMB measurements: South Pole and Dome C (Antarctica), Atacama
(Chile) and Testa Grigia (Italy). An analysis of the polarized signal is
presented and discussed in the framework of future CMB polarization
experiments. We find a typical circularly polarized signal (V Stokes parameter)
of ~ 50 - 300 {\mu}K at 90 GHz looking at the zenith. Among the other sites
Atacama shows the lower polarized signal at the zenith. We present maps of this
signal for the various sites and show typical elevation and azimuth scans. We
find that Dome C presents the lowest gradient in polarized temperature: ~ 0.3
{\mu}K/\circ at 90 GHz. We also study the frequency bands of observation:
around {\nu} \simeq 100 GHz and {\nu} \simeq 160 GHz we find the best
conditions because the polarized signal vanishes. Finally we evaluate the
accuracy of the templates and the signal variability in relation with the
knowledge and the variability of the Earth magnetic field and the atmospheric
parameters.
[8]
oai:arXiv.org:1012.0135 [pdf] - 1579348
On the detectability of cosmic ray electron spectral features in the
microwave/mm-wave range
Submitted: 2010-12-01
Recent measurements of cosmic ray electron energy spectra suggest that above
10 GeV there may be deviations from a single power law spectrum. There are
hints (ATIC) for a bump occurring between 100 GeV and 1TeV, meaning that there
might be more high energy electrons than expected. Whether these electrons are
produced within pulsar magnetospheres, or due to Dark Matter annihilation or
decay, this is still matter of debate. Understanding the nature of these ultra
high energy particles is a difficult task that can be fulfilled using all the
available astrophysical observables. We investigate how different energy
spectra produce different observable manifestations in the
radio/microwave/mm-wave domain, where corresponding deviations from a
synchrotron power law could appear. We raise the question around the
detectability of these possible radio spectral features, which may be
interesting for a wide scientific community including astrophysicists and
scientists working on foregrounds removal for CMB experiments.
[9]
oai:arXiv.org:1010.0645 [pdf] - 1041046
QUBIC: The QU Bolometric Interferometer for Cosmology
The QUBIC collaboration;
Battistelli, E.;
Baù, A.;
Bennett, D.;
Bergé, L.;
Bernard, J. -Ph.;
de Bernardis, P.;
Bounab, A.;
Bréelle, É.;
Bunn, E. F.;
Calvo, M.;
Charlassier, R.;
Collin, S.;
Cruciani, A.;
Curran, G.;
Dumoulin, L.;
Gault, A.;
Gervasi, M.;
Ghribi, A.;
Giard, M.;
Giordano, C.;
Giraud-Héraud, Y.;
Gradziel, M.;
Guglielmi, L.;
Hamilton, J. -Ch.;
Haynes, V.;
Kaplan, J.;
Korotkov, A.;
Landé, J.;
Maffei, B.;
Maiello, M.;
Malu, S.;
Marnieros, S.;
Masi, S.;
Murphy, A.;
Nati, F.;
O'Sullivan, C.;
Pajot, F.;
Passerini, A.;
Peterzen, S.;
Piacentini, F.;
Piat, M.;
Piccirillo, L.;
Pisano, G.;
Polenta, G.;
Prêle, D.;
Romano, D.;
Rosset, C.;
Salatino, M.;
Schillacci, A.;
Sironi, G.;
Sordini, R.;
Spinelli, S.;
Tartari, A.;
Timbie, P.;
Tucker, G.;
Vibert, L.;
Voisin, F.;
Watson, R. A.;
Zannoni, M.
Submitted: 2010-10-04
One of the major challenges of modern cosmology is the detection of B-mode
polarization anisotropies in the CMB. These originate from tensor fluctuations
of the metric produced during the inflationary phase. Their detection would
therefore constitute a major step towards understanding the primordial
Universe. The expected level of these anisotropies is however so small that it
requires a new generation of instruments with high sensitivity and extremely
good control of systematic effects. We propose the QUBIC instrument based on
the novel concept of bolometric interferometry, bringing together the
sensitivity advantages of bolometric detectors with the systematics effects
advantages of interferometry. Methods: The instrument will directly observe the
sky through an array of entry horns whose signals will be combined together
using an optical combiner. The whole set-up is located inside a cryostat.
Polarization modulation will be achieved using a rotating half-wave plate and
interference fringes will be imaged on two focal planes (separated by a
polarizing grid) tiled with bolometers. We show that QUBIC can be considered as
a synthetic imager, exactly similar to a usual imager but with a synthesized
beam formed by the array of entry horns. Scanning the sky provides an
additional modulation of the signal and improve the sky coverage shape. The
usual techniques of map-making and power spectrum estimation can then be
applied. We show that the sensitivity of such an instrument is comparable with
that of an imager with the same number of horns. We anticipate a low level of
beam-related systematics thanks to the fact that the synthesized beam is
determined by the location of the primary horns. Other systematics should be
under good control thanks to an autocalibration technique, specific to our
concept, that will permit the accurate determination of most of the systematics
parameters.
[10]
oai:arXiv.org:1005.4361 [pdf] - 170444
Cosmological observations in the radio domain: the contribution of
extragalactic sources
Submitted: 2010-05-24
The low frequency tail of the CMB spectrum, down along the radio range (~1
GHz), may carry weak spectral distortions which are fingerprints of processes
occurred during different epochs of the thermal history of the Universe, from
z~3\times 10^6 to reionization. TRIS and ARCADE2 are the most recent
experiments dedicated to the exploration of this chapter of CMB cosmology. The
level of instrumental accuracy they reached in the determination of the
absolute sky temperature is such that the removal of galactic and
extra-galactic contamination is the true bottleneck towards the recovery of the
cosmological signal. This will be certainly the case also for future
experiments in the radio domain. Here we present an update of a study
originally done to recognize the contribution of unresolved extra-galactic
radio sources to the sky brightness measured by TRIS. Despite the specific
context which originated our analysis, this is a study of general interest,
improved by the inclusion of all the source counts available up-to-date from
150 MHz to 8.4 GHz.
[11]
oai:arXiv.org:1002.0867 [pdf] - 1513441
SAGACE: the Spectroscopic Active Galaxies And Clusters Explorer
De Bernardis, P.;
Bagliani, D.;
Bardi, A.;
Battistelli, E.;
Birkinshaw, M.;
Calvo, M.;
Colafrancesco, S.;
Conte, A.;
De Gregori, S.;
De Petris, M.;
De Zotti, G.;
Donati, A.;
Ferrari, L.;
Franceschini, A.;
Gatti, F.;
Gervasi, M.;
Giommi, P.;
Giordano, C.;
Gonzalez-Nuevo, J.;
Lamagna, L.;
Lapi, A.;
Luzzi, G.;
Maiolino, R.;
Marchegiani, P.;
Mariani, A.;
Masi, S.;
Massardi, M.;
Mauskopf, P.;
Nati, F.;
Nati, L.;
Natoli, P.;
Negrello, M.;
Piacentini, F.;
Polenta, G.;
Salatino, M.;
Savini, G.;
Schillaci, A.;
Spinelli, S.;
Tartari, A.;
Tavanti, M.;
Tortora, A.;
Vaccari, M.;
Vaccarone, R.;
Zannoni, M.;
Zolesi, V.
Submitted: 2010-02-03
The SAGACE experiment consists of a mm/sub-mm telescope with a 3-m diameter
primary mirror, coupled to a cryogenic multi-beam differential spectrometer.
SAGACE explores the sky in the 100-760 GHz frequency range, using four
diffraction-limited bolometer arrays. The instrument is designed to perform
spectroscopic surveys of the Sunyaev-Zeldovich effects of thousands of galaxy
clusters, of the spectral energy distribution of active galactic nuclei, and of
the [CII] line of a thousand galaxies in the redshift desert. In 2008 a full
phase-A study for a national small mission was completed and delivered to the
Italian Space Agency (ASI). We have shown that taking advantage of the
differential operation of the Fourier Transform Spectrometer, this ambitious
instrument can operate from a Molniya orbit, and can be built and operated
within the tight budget of a small mission.
[12]
oai:arXiv.org:0902.0385 [pdf] - 20948
A demonstrator for bolometric interferometry
Submitted: 2009-02-02
Bolometric Interferometry (BI) is one of the most promising techniques for
precise measurements of the Cosmic Microwave Background polarization. In this
paper, we present the results of DIBO (Demonstrateur d'Interferometrie
Bolometrique), a single-baseline demonstrator operating at 90 GHz, built to
proof the validity of the BI concept applied to a millimeter-wave
interferometer. This instrument has been characterized in the laboratory with a
detector at room temperature and with a 4 K bolometer. This allowed us to
measure interference patterns in a clean way, both (1) rotating the source and
(2) varying with time the phase shift among the two interferometer's arms.
Detailed modelisation has also been performed and validated with measurements.