Normalized to: Sorsa, L.
[1]
oai:arXiv.org:1902.00269 [pdf] - 1959745
Bistatic full-wave radar tomography detects deep interior voids, cracks
and boulders in a rubble-pile asteroid model
Submitted: 2019-02-01, last modified: 2019-09-11
In this paper, we investigate full-wave computed radar tomography (CRT) using
a rubble-pile asteroid model in which a realistic shape (Itokawa) is coupled
with a synthetic material composition and structure model. The aim is to show
that sparse bistatic radar measurements can distinguish details inside a
complex-structured rubble-pile asteroid. The results obtained suggest that
distinct local permittivity distribution changes such as surface layers, voids,
low-permittivity anomalies, high-permittivity boulders, and cracks can be
detected with bistatic CRT, when the total noise level in the data is around
-10 dB with respect to the signal amplitude. Moreover, the bistatic measurement
set-up improves the robustness of the inversion compared to the monostatic
case. Reconstructing the smooth Gaussian background distribution was found to
be difficult with the present approach, suggesting that complementary
techniques, such as gravimetry, might be needed to improve the reliability of
the inference in practice.
[2]
oai:arXiv.org:1903.05461 [pdf] - 2072530
Tomographic inversion of gravity gradient field for a synthetic Itokawa
model
Submitted: 2019-03-13, last modified: 2019-09-11
This article investigates reconstructing the internal mass density of a
numerical asteroid model using the gradient of a simulated gravity field as
synthetic measurement data. Our goal is to advance the mathematical inversion
methodology and find feasibility constraints for the resolution, noise and
orbit selection for future space missions. We base our model on the shape of
the asteroid Itokawa as well as on the recent observations and simulation
studies which suggest that the internal density varies, increasing towards the
center, and that the asteroid may have a detailed structure. We introduce
randomized multiresolution scan algorithm which might provide a robust way to
cancel out bias and artifact effects related to the measurement noise and
numerical discretization. In this scheme, the inverse algorithm can reconstruct
details of various sizes without fixing the exact resolution {\em a priori},
and the randomization minimizes the effect of discretization on the solution.
We show that the adopted methodology provides an advantageous way to diminish
the surface bias of the inverse solution. The results also suggest that a noise
level below 80 Eotvos will be sufficient for the detection of internal voids
and high density anomalies, if a sparse set of measurements can be obtained
from a close-enough distance to the target.