Sorrente, Béatrice
Normalized to: Sorrente, B.
2 article(s) in total. 19 co-authors, from 1 to 2 common article(s). Median position in authors list is 4,5.
[1]
oai:arXiv.org:1109.3131 [pdf] - 1521897
Current results of the PERSEE testbench: the cophasing control and the
polychromatic null rate
Lozi, Julien;
Cassaing, Frederic;
Duigou, Jean-Michel Le;
Sorrente, Beatrice;
Montri, Jospeh;
Reess, Jean-Michel;
Lhome, Emilie;
Buey, Tristan;
Henault, Francois;
Marcotto, Aurelie;
Girard, Paul;
Barillot, Marc;
Ollivier, Marc;
Foresto, Vincent Coude du
Submitted: 2011-09-14
Stabilizing a nulling interferometer at a nanometric level is the key issue
to obtain deep null depths. The PERSEE breadboard has been designed to study
and optimize the operation of a cophased nulling bench in the most realistic
disturbing environment of a space mission. This presentation focuses on the
current results of the PERSEE bench. In terms of metrology, we cophased at 0.33
nm rms for the piston and 80 mas rms for the tip/tilt (0.14% of the Airy disk).
A Linear Quadratic Gaussian (LQG) control coupled with an unsupervised
vibration identification allows us to maintain that level of correction, even
with characteristic vibrations of nulling interferometry space missions. These
performances, with an accurate design and alignment of the bench, currently
lead to a polychromatic unpolarised null depth of 8.9E-6 stabilized at 3E-7 on
the [1.65-2.45] \mum spectral band (37% bandwidth).
[2]
oai:arXiv.org:1008.3081 [pdf] - 216046
PERSEE: Experimental results on the cophased nulling bench
Lozi, Julien;
Cassaing, Frédéric;
Duigou, Jean-Michel Le;
Houairi, Kamel;
Sorrente, Béatrice;
Montri, Joseph;
Jacquinod, Sophie;
Reess, Jean-Michel;
Pham, Laurie;
Lhomé, Emilie;
Buey, Tristan;
Hénault, François;
Marcotto, Aurélie;
Girard, Paul;
Mauclert, Nicolas;
Barillot, Marc;
Foresto, Vincent Coudé du;
Ollivier, Marc
Submitted: 2010-08-18
Nulling interferometry is still a promising method to characterize spectra of
exoplanets. One of the main issues is to cophase at a nanometric level each arm
despite satellite disturbances. The bench PERSEE aims to prove the feasibility
of that technique for spaceborne missions. After a short description of PERSEE,
we will first present the results obtained in a simplified configuration: we
have cophased down to 0.22 nm rms in optical path difference (OPD) and 60 mas
rms in tip/tilt, and have obtained a monochromatic null of 3E-5 stabilized at
3E-6. The goal of 1 nm with additional typical satellite disturbances requires
the use of an optimal control law; that is why we elaborated a dedicated Kalman
filter. Simulations and experiments show a good rejection of disturbances.
Performance of the bench should be enhanced by using a Kalman control law, and
we should be able to reach the desired nanometric stability. Following, we will
present the first results of the final polychromatic configuration, which
includes an achromatic phase shifter, perturbators and optical delay lines. As
a conclusion, we give the first more general lessons we have already learned
from this experiment, both at system and component levels for a future space
mission.