Normalized to: Sonnenschein, A.
[1]
oai:arXiv.org:1907.12509 [pdf] - 2100293
Velocity independent constraints on spin-dependent DM-nucleon
interactions from IceCube and PICO
IceCube Collaboration;
Aartsen, M. G.;
Ackermann, M.;
Adams, J.;
Aguilar, J. A.;
Ahlers, M.;
Ahrens, M.;
Alispach, C.;
Andeen, K.;
Anderson, T.;
Ansseau, I.;
Anton, G.;
Argüelles, C.;
Auffenberg, J.;
Axani, S.;
Backes, P.;
Bagherpour, H.;
Bai, X.;
V., A. Balagopal;
Barbano, A.;
Barwick, S. W.;
Bastian, B.;
Baum, V.;
Baur, S.;
Bay, R.;
Beatty, J. J.;
Becker, K. -H.;
Tjus, J. Becker;
BenZvi, S.;
Berley, D.;
Bernardini, E.;
Besson, D. Z.;
Binder, G.;
Bindig, D.;
Blaufuss, E.;
Blot, S.;
Bohm, C.;
Börner, M.;
Böser, S.;
Botner, O.;
Böttcher, J.;
Bourbeau, E.;
Bourbeau, J.;
Bradascio, F.;
Braun, J.;
Bron, S.;
Brostean-Kaiser, J.;
Burgman, A.;
Buscher, J.;
Busse, R. S.;
Carver, T.;
Chen, C.;
Cheung, E.;
Chirkin, D.;
Choi, S.;
Classen, L.;
Coleman, A.;
Collin, G. H.;
Conrad, J. M.;
Coppin, P.;
Correa, P.;
Cowen, D. F.;
Cross, R.;
Dave, P.;
De Clercq, C.;
DeLaunay, J. J.;
Dembinski, H.;
Deoskar, K.;
De Ridder, S.;
Desiati, P.;
de Vries, K. D.;
de Wasseige, G.;
de With, M.;
DeYoung, T.;
Diaz, A.;
Díaz-Vélez, J. C.;
Dujmovic, H.;
Dunkman, M.;
Dvorak, E.;
Eberhardt, B.;
Ehrhardt, T.;
Eller, P.;
Engel, R.;
Evenson, P. A.;
Fahey, S.;
Fazely, A. R.;
Felde, J.;
Filimonov, K.;
Finley, C.;
Franckowiak, A.;
Friedman, E.;
Fritz, A.;
Gaisser, T. K.;
Gallagher, J.;
Ganster, E.;
Garrappa, S.;
Gerhardt, L.;
Ghorbani, K.;
Glauch, T.;
Glüsenkamp, T.;
Goldschmidt, A.;
Gonzalez, J. G.;
Grant, D.;
Griffith, Z.;
Griswold, S.;
Günder, M.;
Gündüz, M.;
Haack, C.;
Hallgren, A.;
Halve, L.;
Halzen, F.;
Hanson, K.;
Haungs, A.;
Hebecker, D.;
Heereman, D.;
Heix, P.;
Helbing, K.;
Hellauer, R.;
Henningsen, F.;
Hickford, S.;
Hignight, J.;
Hill, G. C.;
Hoffman, K. D.;
Hoffmann, R.;
Hoinka, T.;
Hokanson-Fasig, B.;
Hoshina, K.;
Huang, F.;
Huber, M.;
Huber, T.;
Hultqvist, K.;
Hünnefeld, M.;
Hussain, R.;
In, S.;
Iovine, N.;
Ishihara, A.;
Japaridze, G. S.;
Jeong, M.;
Jero, K.;
Jones, B. J. P.;
Jonske, F.;
Joppe, R.;
Kang, D.;
Kang, W.;
Kappes, A.;
Kappesser, D.;
Karg, T.;
Karl, M.;
Karle, A.;
Katz, U.;
Kauer, M.;
Kelley, J. L.;
Kheirandish, A.;
Kim, J.;
Kintscher, T.;
Kiryluk, J.;
Kittler, T.;
Klein, S. R.;
Koirala, R.;
Kolanoski, H.;
Köpke, L.;
Kopper, C.;
Kopper, S.;
Koskinen, D. J.;
Kowalski, M.;
Krings, K.;
Krückl, G.;
Kulacz, N.;
Kurahashi, N.;
Kyriacou, A.;
Labare, M.;
Lanfranchi, J. L.;
Larson, M. J.;
Lauber, F.;
Lazar, J. P.;
Leonard, K.;
Leszczyńska, A.;
Leuermann, M.;
Liu, Q. R.;
Lohfink, E.;
Mariscal, C. J. Lozano;
Lu, L.;
Lucarelli, F.;
Lünemann, J.;
Luszczak, W.;
Lyu, Y.;
Ma, W. Y.;
Madsen, J.;
Maggi, G.;
Mahn, K. B. M.;
Makino, Y.;
Mallik, P.;
Mallot, K.;
Mancina, S.;
Mariş, I. C.;
Maruyama, R.;
Mase, K.;
Maunu, R.;
McNally, F.;
Meagher, K.;
Medici, M.;
Medina, A.;
Meier, M.;
Meighen-Berger, S.;
Menne, T.;
Merino, G.;
Meures, T.;
Micallef, J.;
Mockler, D.;
Momenté, G.;
Montaruli, T.;
Moore, R. W.;
Morse, R.;
Moulai, M.;
Muth, P.;
Nagai, R.;
Naumann, U.;
Neer, G.;
Niederhausen, H.;
Nowicki, S. C.;
Nygren, D. R.;
Pollmann, A. Obertacke;
Oehler, M.;
Olivas, A.;
O'Murchadha, A.;
O'Sullivan, E.;
Palczewski, T.;
Pandya, H.;
Pankova, D. V.;
Park, N.;
Peiffer, P.;
Heros, C. Pérez de los;
Philippen, S.;
Pieloth, D.;
Pinat, E.;
Pizzuto, A.;
Plum, M.;
Porcelli, A.;
Price, P. B.;
Przybylski, G. T.;
Raab, C.;
Raissi, A.;
Rameez, M.;
Rauch, L.;
Rawlins, K.;
Rea, I. C.;
Reimann, R.;
Relethford, B.;
Renschler, M.;
Renzi, G.;
Resconi, E.;
Rhode, W.;
Richman, M.;
Robertson, S.;
Rongen, M.;
Rott, C.;
Ruhe, T.;
Ryckbosch, D.;
Rysewyk, D.;
Safa, I.;
Herrera, S. E. Sanchez;
Sandrock, A.;
Sandroos, J.;
Santander, M.;
Sarkar, S.;
Sarkar, S.;
Satalecka, K.;
Schaufel, M.;
Schieler, H.;
Schlunder, P.;
Schmidt, T.;
Schneider, A.;
Schneider, J.;
Schröder, F. G.;
Schumacher, L.;
Sclafani, S.;
Seckel, D.;
Seunarine, S.;
Shefali, S.;
Silva, M.;
Snihur, R.;
Soedingrekso, J.;
Soldin, D.;
Song, M.;
Spiczak, G. M.;
Spiering, C.;
Stachurska, J.;
Stamatikos, M.;
Stanev, T.;
Stein, R.;
Steinmüller, P.;
Stettner, J.;
Steuer, A.;
Stezelberger, T.;
Stokstad, R. G.;
Stößl, A.;
Strotjohann, N. L.;
Stürwald, T.;
Stuttard, T.;
Sullivan, G. W.;
Taboada, I.;
Tenholt, F.;
Ter-Antonyan, S.;
Terliuk, A.;
Tilav, S.;
Tomankova, L.;
Tönnis, C.;
Toscano, S.;
Tosi, D.;
Trettin, A.;
Tselengidou, M.;
Tung, C. F.;
Turcati, A.;
Turcotte, R.;
Turley, C. F.;
Ty, B.;
Unger, E.;
Elorrieta, M. A. Unland;
Usner, M.;
Vandenbroucke, J.;
Van Driessche, W.;
van Eijk, D.;
van Eijndhoven, N.;
Vanheule, S.;
van Santen, J.;
Vraeghe, M.;
Walck, C.;
Wallace, A.;
Wallraff, M.;
Wandkowsky, N.;
Watson, T. B.;
Weaver, C.;
Weindl, A.;
Weiss, M. J.;
Weldert, J.;
Wendt, C.;
Werthebach, J.;
Whelan, B. J.;
Whitehorn, N.;
Wiebe, K.;
Wiebusch, C. H.;
Wille, L.;
Williams, D. R.;
Wills, L.;
Wolf, M.;
Wood, J.;
Wood, T. R.;
Woschnagg, K.;
Wrede, G.;
Xu, D. L.;
Xu, X. W.;
Xu, Y.;
Yanez, J. P.;
Yodh, G.;
Yoshida, S.;
Yuan, T.;
Collaboration, M. Zöcklein. PICO;
:;
Amole, C.;
Ardid, M.;
Arnquist, I. J.;
Asner, D. M.;
Baxter, D.;
Behnke, E.;
Bressler, M.;
Broerman, B.;
Cao, G.;
Chen, C. J.;
Chowdhury, U.;
Clark, K.;
Collar, J. I.;
Cooper, P. S.;
Crisler, M.;
Crowder, G.;
Cruz-Venegas, N. A.;
Dahl, C. E.;
Das, M.;
Fallows, S.;
Farine, J.;
Felis, I.;
Filgas, R.;
Girard, F.;
Giroux, G.;
Hall, J.;
Hardy, C.;
Harris, O.;
Hoppe, E. W.;
Jin, M.;
Klopfenstein, L.;
Krauss, C. B.;
Laurin, M.;
Lawson, I.;
Leblanc, A.;
Levine, I.;
Lippincott, W. H.;
Mamedov, F.;
Maurya, D.;
Mitra, P.;
Moore, C.;
Nania, T.;
Neilson, R.;
Noble, A. J.;
Oedekerk, P.;
Ortega, A.;
Piro, M. -C.;
Plante, A.;
Podviyanuk, R.;
Priya, S.;
Robinson, A. E.;
Sahoo, S.;
Scallon, O.;
Seth, S.;
Sonnenschein, A.;
Starinski, N.;
Štekl, I.;
Sullivan, T.;
Tardif, F.;
Vázquez-Jáuregui, E.;
Walkowski, N.;
Wichoski, U.;
Yan, Y.;
Zacek, V.;
Zhang, J.
Submitted: 2019-07-29, last modified: 2020-05-25
Adopting the Standard Halo Model (SHM) of an isotropic Maxwellian velocity
distribution for dark matter (DM) particles in the Galaxy, the most stringent
current constraints on their spin-dependent scattering cross-section with
nucleons come from the IceCube neutrino observatory and the PICO-60 C$_3$F$_8$
superheated bubble chamber experiments. The former is sensitive to high energy
neutrinos from the self-annihilation of DM particles captured in the Sun, while
the latter looks for nuclear recoil events from DM scattering off nucleons.
Although slower DM particles are more likely to be captured by the Sun, the
faster ones are more likely to be detected by PICO. Recent N-body simulations
suggest significant deviations from the SHM for the smooth halo component of
the DM, while observations hint at a dominant fraction of the local DM being in
substructures. We use the method of Ferrer et al. (2015) to exploit the
complementarity between the two approaches and derive conservative constraints
on DM-nucleon scattering. Our results constrain $\sigma_{\mathrm{SD}} \lesssim
3 \times 10^{-39} \mathrm{cm}^2$ (6 $ \times 10^{-38} \mathrm{cm}^2$) at
$\gtrsim 90\%$ C.L. for a DM particle of mass 1~TeV annihilating into $\tau^+
\tau^-$ ($b\bar{b}$) with a local density of $\rho_{\mathrm{DM}} = 0.3~\mathrm{
GeV/cm}^3$. The constraints scale inversely with $\rho_{\mathrm{DM}}$ and are
independent of the DM velocity distribution.
[2]
oai:arXiv.org:1905.12522 [pdf] - 1995410
Data-Driven Modeling of Electron Recoil Nucleation in PICO C$_3$F$_8$
Bubble Chambers
Amole, C.;
Ardid, M.;
Arnquist, I. J.;
Asner, D. M.;
Baxter, D.;
Behnke, E.;
Bressler, M.;
Broerman, B.;
Cao, G.;
Chen, C. J.;
Chen, S.;
Chowdhury, U.;
Clark, K.;
Collar, J. I.;
Cooper, P. S.;
Coutu, C. B.;
Cowles, C.;
Crisler, M.;
Crowder, G.;
Cruz-Venegas, N. A.;
Dahl, C. E.;
Das, M.;
Fallows, S.;
Farine, J.;
Filgas, R.;
Fuentes, J.;
Girard, F.;
Giroux, G.;
Hackett, B.;
Hagen, A.;
Hall, J.;
Hardy, C.;
Harris, O.;
Hillier, T.;
Hoppe, E. W.;
Jackson, C. M.;
Jin, M.;
Klopfenstein, L.;
Kozynets, T.;
Krauss, C. B.;
Laurin, M.;
Lawson, I.;
Leblanc, A.;
Levine, I.;
Licciardi, C.;
Lippincott, W. H.;
Loer, B.;
Mamedov, F.;
Mitra, P.;
Moore, C.;
Nania, T.;
Neilson, R.;
Noble, A. J.;
Oedekerk, P.;
Ortega, A.;
Pal, S.;
Piro, M. -C.;
Plante, A.;
Priya, S.;
Robinson, A. E.;
Sahoo, S.;
Scallon, O.;
Seth, S.;
Sonnenschein, A.;
Starinski, N.;
Štekl, I.;
Sullivan, T.;
Tardif, F.;
Tiwari, D.;
Vázquez-Jáuregui, E.;
Wagner, J. M.;
Walkowski, N.;
Weima, E.;
Wichoski, U.;
Wierman, K.;
Woodley, W.;
Yan, Y.;
Zacek, V.;
Zhang, J.
Submitted: 2019-05-29, last modified: 2019-11-06
The primary advantage of moderately superheated bubble chamber detectors is
their simultaneous sensitivity to nuclear recoils from WIMP dark matter and
insensitivity to electron recoil backgrounds. A comprehensive analysis of PICO
gamma calibration data demonstrates for the first time that electron recoils in
C$_3$F$_8$ scale in accordance with a new nucleation mechanism, rather than one
driven by a hot-spike as previously supposed. Using this semi-empirical model,
bubble chamber nucleation thresholds may be tuned to be sensitive to lower
energy nuclear recoils while maintaining excellent electron recoil rejection.
The PICO-40L detector will exploit this model to achieve thermodynamic
thresholds as low as 2.8 keV while being dominated by single-scatter events
from coherent elastic neutrino-nucleus scattering of solar neutrinos. In one
year of operation, PICO-40L can improve existing leading limits from PICO on
spin-dependent WIMP-proton coupling by nearly an order of magnitude for WIMP
masses greater than 3 GeV c$^{-2}$ and will have the ability to surpass all
existing non-xenon bounds on spin-independent WIMP-nucleon coupling for WIMP
masses from 3 to 40 GeV c$^{-2}$.
[3]
oai:arXiv.org:1910.08638 [pdf] - 2065294
Extended Search for the Invisible Axion with the Axion Dark Matter
Experiment
Braine, T.;
Cervantes, R.;
Crisosto, N.;
Du, N.;
Kimes, S.;
Rosenberg, L. J;
Rybka, G.;
Yang, J.;
Bowring, D.;
Chou, A. S.;
Khatiwada, R.;
Sonnenschein, A.;
Wester, W.;
Carosi, G.;
Woollett, N.;
Duffy, L. D.;
Bradley, R.;
Boutan, C.;
Jones, M.;
LaRoque, B. H.;
Oblath, N. S.;
Taubman, M. S.;
Clarke, J.;
Dove, A.;
Eddins, A.;
O'Kelley, S. R.;
Nawaz, S.;
Siddiqi, I.;
Stevenson, N.;
Agrawal, A.;
Dixit, A. V.;
Gleason, J. R.;
Jois, S.;
Sikivie, P.;
Sullivan, N. S.;
Tanner, D. B.;
Lentz, E.;
Daw, E. J.;
Buckley, J. H.;
Harrington, P. M.;
Henriksen, E. A.;
Murch, K. W.
Submitted: 2019-10-18, last modified: 2019-11-01
This paper reports on a cavity haloscope search for dark matter axions in the
galactic halo in the mass range $2.81$-$3.31$ ${\mu}eV$. This search excludes
the full range of axion-photon coupling values predicted in benchmark models of
the invisible axion that solve the strong CP problem of quantum chromodynamics,
and marks the first time a haloscope search has been able to search for axions
at mode crossings using an alternate cavity configuration. Unprecedented
sensitivity in this higher mass range is achieved by deploying an ultra
low-noise Josephson parametric amplifier as the first stage signal amplifier.
[4]
oai:arXiv.org:1902.04031 [pdf] - 1916812
Dark Matter Search Results from the Complete Exposure of the PICO-60
C$_3$F$_8$ Bubble Chamber
Amole, C.;
Ardid, M.;
Arnquist, I. J.;
Asner, D. M.;
Baxter, D.;
Behnke, E.;
Bressler, M.;
Broerman, B.;
Cao, G.;
Chen, C. J.;
Chowdhury, U.;
Clark, K.;
Collar, J. I.;
Cooper, P. S.;
Coutu, C. B.;
Cowles, C.;
Crisler, M.;
Crowder, G.;
Cruz-Venegas, N. A.;
Dahl, C. E.;
Das, M.;
Fallows, S.;
Farine, J.;
Felis, I.;
Filgas, R.;
Girard, F.;
Giroux, G.;
Hall, J.;
Hardy, C.;
Harris, O.;
Hillier, T.;
Hoppe, E. W.;
Jackson, C. M.;
Jin, M.;
Klopfenstein, L.;
Krauss, C. B.;
Laurin, M.;
Lawson, I.;
Leblanc, A.;
Levine, I.;
Licciardi, C.;
Lippincott, W. H.;
Loer, B.;
Mamedov, F.;
Mitra, P.;
Moore, C.;
Nania, T.;
Neilson, R.;
Noble, A. J.;
Oedekerk, P.;
Ortega, A.;
Piro, M. -C.;
Plante, A.;
Podviyanuk, R.;
Priya, S.;
Robinson, A. E.;
Sahoo, S.;
Scallon, O.;
Seth, S.;
Sonnenschein, A.;
Starinski, N.;
Štekl, I.;
Sullivan, T.;
Tardif, F.;
Vázquez-Jáuregui, E.;
Walkowski, N.;
Weima, E.;
Wichoski, U.;
Wierman, K.;
Yan, Y.;
Zacek, V.;
Zhang, J.
Submitted: 2019-02-11
Final results are reported from operation of the PICO-60 C$_3$F$_8$ dark
matter detector, a bubble chamber filled with 52 kg of C$_3$F$_8$ located in
the SNOLAB underground laboratory. The chamber was operated at thermodynamic
thresholds as low as 1.2 keV without loss of stability. A new blind 1404-kg-day
exposure at 2.45 keV threshold was acquired with approximately the same
expected total background rate as the previous 1167-kg-day exposure at 3.3 keV.
This increased exposure is enabled in part by a new optical tracking analysis
to better identify events near detector walls, permitting a larger fiducial
volume. These results set the most stringent direct-detection constraint to
date on the WIMP-proton spin-dependent cross section at 2.5 $\times$ 10$^{-41}$
cm$^2$ for a 25 GeV WIMP, and improve on previous PICO results for 3-5 GeV
WIMPs by an order of magnitude.
[5]
oai:arXiv.org:1901.00920 [pdf] - 1809667
Piezoelectrically Tuned Multimode Cavity Search for Axion Dark Matter
Boutan, C.;
Jones, M.;
LaRoque, B. H.;
Oblath, N. S.;
Cervantes, R.;
Du, N.;
Force, N.;
Kimes, S.;
Ottens, R.;
Rosenberg, L. J.;
Rybka, G.;
Yang, J.;
Carosi, G.;
Woollett, N.;
Bowring, D.;
Chou, A. S.;
Khatiwada, R.;
Sonnenschein, A.;
Wester, W.;
Bradley, R.;
Daw, E. J.;
Agrawal, A.;
Dixit, A. V.;
Clarke, J.;
O'Kelley, S. R.;
Crisosto, N.;
Gleason, J. R.;
Jois, S.;
Sikivie, P.;
Stern, I.;
Sullivan, N. S.;
Tanner, D. B.;
Harrington, P. M.;
Lentz, E.
Submitted: 2019-01-03
The $\mu$eV axion is a well-motivated extension to the standard model. The
Axion Dark Matter eXperiment (ADMX) collaboration seeks to discover this
particle by looking for the resonant conversion of dark-matter axions to
microwave photons in a strong magnetic field. In this Letter, we report results
from a pathfinder experiment, the ADMX "Sidecar," which is designed to pave the
way for future, higher mass, searches. This testbed experiment lives inside of
and operates in tandem with the main ADMX experiment. The Sidecar experiment
excludes masses in three widely spaced frequency ranges (4202-4249, 5086-5799,
and 7173-7203 MHz). In addition, Sidecar demonstrates the successful use of a
piezoelectric actuator for cavity tuning. Finally, this publication is the
first to report data measured using both the TM$_{010}$ and TM$_{020}$ modes.
[6]
oai:arXiv.org:1804.05750 [pdf] - 1666906
A Search for Invisible Axion Dark Matter with the Axion Dark Matter
Experiment
Du, N.;
Force, N.;
Khatiwada, R.;
Lentz, E.;
Ottens, R.;
Rosenberg, L. J;
Rybka, G.;
Carosi, G.;
Woolett, N.;
Bowring, D.;
Chou, A. S.;
Sonnenschein, A.;
Wester, W.;
Boutan, C.;
Oblath, N. S.;
Bradley, R.;
Daw, E. J.;
Dixit, A. V.;
Clarke, J.;
O'Kelley, S. R.;
Crisosto, N.;
Gleason, J. R.;
Jois, S.;
Sikivie, P.;
Stern, I.;
Sullivan, N. S.;
Tanner, D. B.;
Hilton, G. C.
Submitted: 2018-04-16, last modified: 2018-04-17
This Letter reports results from a haloscope search for dark matter axions
with masses between 2.66 and 2.81 $\mu$eV. The search excludes the range of
axion-photon couplings predicted by plausible models of the invisible axion.
This unprecedented sensitivity is achieved by operating a large-volume
haloscope at sub-kelvin temperatures, thereby reducing thermal noise as well as
the excess noise from the ultra-low-noise SQUID amplifier used for the signal
power readout. Ongoing searches will provide nearly definitive tests of the
invisible axion model over a wide range of axion masses.
[7]
oai:arXiv.org:1702.07666 [pdf] - 1581621
Dark Matter Search Results from the PICO-60 C$_3$F$_8$ Bubble Chamber
Amole, C.;
Ardid, M.;
Arnquist, I. J.;
Asner, D. M.;
Baxter, D.;
Behnke, E.;
Bhattacharjee, P.;
Borsodi, H.;
Bou-Cabo, M.;
Campion, P.;
Cao, G.;
Chen, C. J.;
Chowdhury, U.;
Clark, K.;
Collar, J. I.;
Cooper, P. S.;
Crisler, M.;
Crowder, G.;
Dahl, C. E.;
Das, M.;
Fallows, S.;
Farine, J.;
Felis, I.;
Filgas, R.;
Girard, F.;
Giroux, G.;
Hall, J.;
Harris, O.;
Hoppe, E. W.;
Jin, M.;
Krauss, C. B.;
Laurin, M.;
Lawson, I.;
Leblanc, A.;
Levine, I.;
Lippincott, W. H.;
Mamedov, F.;
Maurya, D.;
Mitra, P.;
Nania, T.;
Neilson, R.;
Noble, A. J.;
Olson, S.;
Ortega, A.;
Plante, A.;
Podviyanuk, R.;
Priya, S.;
Robinson, A. E.;
Roeder, A.;
Rucinski, R.;
Scallon, O.;
Seth, S.;
Sonnenschein, A.;
Starinski, N.;
Štekl, I.;
Tardif, F.;
Vázquez-Jáuregui, E.;
Wells, J.;
Wichoski, U.;
Yan, Y.;
Zacek, V.;
Zhang, J.
Submitted: 2017-02-24, last modified: 2017-08-02
New results are reported from the operation of the PICO-60 dark matter
detector, a bubble chamber filled with 52 kg of C$_3$F$_8$ located in the
SNOLAB underground laboratory. As in previous PICO bubble chambers, PICO-60
C$_3$F$_8$ exhibits excellent electron recoil and alpha decay rejection, and
the observed multiple-scattering neutron rate indicates a single-scatter
neutron background of less than 1 event per month. A blind analysis of an
efficiency-corrected 1167-kg-day exposure at a 3.3-keV thermodynamic threshold
reveals no single-scattering nuclear recoil candidates, consistent with the
predicted background. These results set the most stringent direct-detection
constraint to date on the WIMP-proton spin-dependent cross section at 3.4
$\times$ 10$^{-41}$ cm$^2$ for a 30-GeV$\thinspace$c$^{-2}$ WIMP, more than one
order of magnitude improvement from previous PICO results.
[9]
oai:arXiv.org:1601.03729 [pdf] - 1382109
Improved dark matter search results from PICO-2L Run 2
Amole, C.;
Ardid, M.;
Arnquist, I. J.;
Asner, D. M.;
Baxter, D.;
Behnke, E.;
Bhattacharjee, P.;
Borsodi, H.;
Bou-Cabo, M.;
Brice, S. J.;
Broemmelsiek, D.;
Clark, K.;
Collar, J. I.;
Cooper, P. S.;
Crisler, M.;
Dahl, C. E.;
Das, M.;
Debris, F.;
Fallows, S.;
Farine, J.;
Felis, I.;
Filgas, R.;
Fines-Neuschild, M.;
Girard, F.;
Giroux, G.;
Hall, J.;
Harris, O.;
Hoppe, E. W.;
Jackson, C. M.;
Jin, M.;
Krauss, C. B.;
Lafrenière, M.;
Laurin, M.;
Lawson, I.;
Leblanc, A.;
Levine, I.;
Lippincott, W. H.;
Mann, E.;
Martin, J. P.;
Maurya, D.;
Mitra, P.;
Olson, S.;
Neilson, R.;
Noble, A. J.;
Plante, A.;
Podviianiuk, R. B.;
Priya, S.;
Robinson, A. E.;
Ruschman, M.;
Scallon, O.;
Sonnenschein, A.;
Starinski, N.;
Štekl, I.;
Vázquez-Jáuregui, E.;
Wells, J.;
Wichoski, U.;
Zacek, V.;
Zhang, J.
Submitted: 2016-01-14, last modified: 2016-03-25
New data are reported from a second run of the 2-liter PICO-2L C$_3$F$_8$
bubble chamber with a total exposure of 129$\,$kg-days at a thermodynamic
threshold energy of 3.3$\,$keV. These data show that measures taken to control
particulate contamination in the superheated fluid resulted in the absence of
the anomalous background events observed in the first run of this bubble
chamber. One single nuclear-recoil event was observed in the data, consistent
both with the predicted background rate from neutrons and with the observed
rate of unambiguous multiple-bubble neutron scattering events. The chamber
exhibits the same excellent electron-recoil and alpha decay rejection as was
previously reported. These data provide the most stringent direct detection
constraints on weakly interacting massive particle (WIMP)-proton spin-dependent
scattering to date for WIMP masses $<$ 50$\,$GeV/c$^2$.
[10]
oai:arXiv.org:1510.07754 [pdf] - 1382070
Dark Matter Search Results from the PICO-60 CF$_3$I Bubble Chamber
Amole, C.;
Ardid, M.;
Asner, D. M.;
Baxter, D.;
Behnke, E.;
Bhattacharjee, P.;
Borsodi, H.;
Bou-Cabo, M.;
Brice, S. J.;
Broemmelsiek, D.;
Clark, K.;
Collar, J. I.;
Cooper, P. S.;
Crisler, M.;
Dahl, C. E.;
Daley, S.;
Das, M.;
Debris, F.;
Dhungana, N.;
Farine, J.;
Felis, I.;
Filgas, R.;
Girard, F.;
Giroux, G.;
Grandison, A.;
Hai, M.;
Hall, J.;
Harris, O.;
Jin, M.;
Krauss, C. B.;
Fallows, S.;
Lafrenière, M.;
Laurin, M.;
Lawson, I.;
Levine, I.;
Lippincott, W. H.;
Mann, E.;
Maurya, D.;
Mitra, P.;
Neilson, R.;
Noble, A. J.;
Plante, A.;
Podviianiuk, R. B.;
Priya, S.;
Ramberg, E.;
Robinson, A. E.;
Rucinski, R.;
Ruschman, M.;
Scallon, O.;
Seth, S.;
Simon, P.;
Sonnenschein, A.;
Štekl, I.;
Vàzquez-Jàuregui, E.;
Wells, J.;
Wichoski, U.;
Zacek, V.;
Zhang, J.;
Shkrob, I. A.
Submitted: 2015-10-26, last modified: 2016-03-03
New data are reported from the operation of the PICO-60 dark matter detector,
a bubble chamber filled with 36.8 kg of CF$_3$I and located in the SNOLAB
underground laboratory. PICO-60 is the largest bubble chamber to search for
dark matter to date. With an analyzed exposure of 92.8 livedays, PICO-60
exhibits the same excellent background rejection observed in smaller bubble
chambers. Alpha decays in PICO-60 exhibit frequency-dependent acoustic
calorimetry, similar but not identical to that reported recently in a
C$_3$F$_8$ bubble chamber. PICO-60 also observes a large population of unknown
background events, exhibiting acoustic, spatial, and timing behaviors
inconsistent with those expected from a dark matter signal. These behaviors
allow for analysis cuts to remove all background events while retaining
$48.2\%$ of the exposure. Stringent limits on weakly interacting massive
particles interacting via spin-dependent proton and spin-independent processes
are set, and most interpretations of the DAMA/LIBRA modulation signal as dark
matter interacting with iodine nuclei are ruled out.
[11]
oai:arXiv.org:1503.00008 [pdf] - 1238863
Dark Matter Search Results from the PICO-2L C$_3$F$_8$ Bubble Chamber
Amole, C.;
Ardid, M.;
Asner, D. M.;
Baxter, D.;
Behnke, E.;
Bhattacharjee, P.;
Borsodi, H.;
Bou-Cabo, M.;
Brice, S. J.;
Broemmelsiek, D.;
Clark, K.;
Collar, J. I.;
Cooper, P. S.;
Crisler, M.;
Dahl, C. E.;
Daley, S.;
Das, M.;
Debris, F.;
Dhungana, N.;
Farine, J.;
Felis, I.;
Filgas, R.;
Fines-Neuschild, M.;
Girard, F.;
Giroux, G.;
Hai, M.;
Hall, J.;
Harris, O.;
Jackson, C. M.;
Jin, M.;
Krauss, C. B.;
Lafrenière, M.;
Laurin, M.;
Lawson, I.;
Levine, I.;
Lippincott, W. H.;
Mann, E.;
Martin, J. P.;
Maurya, D.;
Mitra, P.;
Neilson, R.;
Noble, A. J.;
Plante, A.;
Podviianiuk, R. B.;
Priya, S.;
Robinson, A. E.;
Ruschman, M.;
Scallon, O.;
Seth, S.;
Sonnenschein, A.;
Starinski, N.;
Štekl, I.;
Vàzquez-Jaùregui, E.;
Wells, J.;
Wichoski, U.;
Zacek, V.;
Zhang, J.
Submitted: 2015-02-27, last modified: 2015-06-29
New data are reported from the operation of a 2-liter C$_3$F$_8$ bubble
chamber in the 2100 meter deep SNOLAB underground laboratory, with a total
exposure of 211.5 kg-days at four different recoil energy thresholds ranging
from 3.2 keV to 8.1 keV. These data show that C3F8 provides excellent electron
recoil and alpha rejection capabilities at very low thresholds, including the
first observation of a dependence of acoustic signal on alpha energy. Twelve
single nuclear recoil event candidates were observed during the run. The
candidate events exhibit timing characteristics that are not consistent with
the hypothesis of a uniform time distribution, and no evidence for a dark
matter signal is claimed. These data provide the most sensitive direct
detection constraints on WIMP-proton spin-dependent scattering to date, with
significant sensitivity at low WIMP masses for spin-independent WIMP-nucleon
scattering.
[12]
oai:arXiv.org:1501.06883 [pdf] - 1323345
Bubble Chambers for Experiments in Nuclear Astrophysics
DiGiovine, B.;
Henderson, D.;
Holt, R. J.;
Rehm, K. E.;
Raut, R.;
Robinson, A.;
Sonnenschein, A.;
Rusev, G.;
Tonchev, A. P.;
Ugalde, C.
Submitted: 2015-01-27
A bubble chamber has been developed to be used as an active target system for
low energy nuclear astrophysics experiments. Adopting ideas from dark matter
detection with superheated liquids, a detector system compatible with gamma-ray
beams has been developed. This detector alleviates some of the limitations
encountered in standard measurements of the minute cross sections of interest
to stellar environments. While the astrophysically relevant nuclear reaction
processes at hydrostatic burning temperatures are dominated by radiative
captures, in this experimental scheme we measure the time-reversed processes.
Such photodisintegrations allow us to compute the radiative capture cross
sections when transitions to excited states of the reaction products are
negligible. Due to the transformation of phase space, the photodisintegration
cross sections are up to two orders of magnitude higher. The main advantage of
the new target-detector system is a density several orders of magnitude higher
than conventional gas targets. Also, the detector is virtually insensitive to
the gamma-ray beam itself, thus allowing us to detect only the products of the
nuclear reaction of interest. The development and the operation as well as the
advantages and disadvantages of the bubble chamber are discussed.
[13]
oai:arXiv.org:1304.6001 [pdf] - 778562
Direct Measurement of the Bubble Nucleation Energy Threshold in a CF3I
Bubble Chamber
COUPP Collaboration;
Behnke, E.;
Benjamin, T.;
Brice, S. J.;
Broemmelsiek, D.;
Collar, J. I.;
Cooper, P. S.;
Crisler, M.;
Dahl, C. E.;
Fustin, D.;
Hall, J.;
Harnish, C.;
Levine, I.;
Lippincott, W. H.;
Moan, T.;
Nania, T.;
Neilson, R.;
Ramberg, E.;
Robinson, A. E.;
Sonnenschein, A.;
Vázquez-Jáuregui, E.;
Rivera, R. A.;
Uplegger, L.
Submitted: 2013-04-22, last modified: 2014-01-31
We have directly measured the energy threshold and efficiency for bubble
nucleation from iodine recoils in a CF3I bubble chamber in the energy range of
interest for a dark matter search. These interactions cannot be probed by
standard neutron calibration methods, so we develop a new technique by
observing the elastic scattering of 12 GeV/c negative pions. The pions are
tracked with a silicon pixel telescope and the reconstructed scattering angle
provides a measure of the nuclear recoil kinetic energy. The bubble chamber was
operated with a nominal threshold of (13.6+-0.6) keV. Interpretation of the
results depends on the response to fluorine and carbon recoils, but in general
we find agreement with the predictions of the classical bubble nucleation
theory. This measurement confirms the applicability of CF3I as a target for
spin-independent dark matter interactions and represents a novel technique for
calibration of superheated fluid detectors.
[14]
oai:arXiv.org:1310.8327 [pdf] - 741475
Snowmass CF1 Summary: WIMP Dark Matter Direct Detection
Cushman, P.;
Galbiati, C.;
McKinsey, D. N.;
Robertson, H.;
Tait, T. M. P.;
Bauer, D.;
Borgland, A.;
Cabrera, B.;
Calaprice, F.;
Cooley, J.;
Empl, T.;
Essig, R.;
Figueroa-Feliciano, E.;
Gaitskell, R.;
Golwala, S.;
Hall, J.;
Hill, R.;
Hime, A.;
Hoppe, E.;
Hsu, L.;
Hungerford, E.;
Jacobsen, R.;
Kelsey, M.;
Lang, R. F.;
Lippincott, W. H.;
Loer, B.;
Luitz, S.;
Mandic, V.;
Mardon, J.;
Maricic, J.;
Maruyama, R.;
Mahapatra, R.;
Nelson, H.;
Orrell, J.;
Palladino, K.;
Pantic, E.;
Partridge, R.;
Ryd, A.;
Saab, T.;
Sadoulet, B.;
Schnee, R.;
Shepherd, W.;
Sonnenschein, A.;
Sorensen, P.;
Szydagis, M.;
Volansky, T.;
Witherell, M.;
Wright, D.;
Zurek, K.
Submitted: 2013-10-30, last modified: 2013-11-03
As part of the Snowmass process, the Cosmic Frontier WIMP Direct Detection
subgroup (CF1) has drawn on input from the Cosmic Frontier and the broader
Particle Physics community to produce this document. The charge to CF1 was (a)
to summarize the current status and projected sensitivity of WIMP direct
detection experiments worldwide, (b) motivate WIMP dark matter searches over a
broad parameter space by examining a spectrum of WIMP models, (c) establish a
community consensus on the type of experimental program required to explore
that parameter space, and (d) identify the common infrastructure required to
practically meet those goals.
[15]
oai:arXiv.org:1212.6819 [pdf] - 1158742
First determination of an astrophysical cross section with a bubble
chamber: the 15N(\alpha,\gamma)19F reaction
Ugalde, C.;
DiGiovine, B.;
Henderson, D.;
Holt, R. J.;
Rehm, K. E.;
Sonnenschein, A.;
Robinson, A.;
Raut, R.;
Rusev, G.;
Tonchev, A. P.
Submitted: 2012-12-30
We have devised a technique for measuring some of the most important nuclear
reactions in stars which we expect to provide considerable improvement over
previous experiments. Adapting ideas from dark matter search experiments with
bubble chambers, we have found that a superheated liquid is sensitive to
recoils produced from \gamma-rays photodisintegrating the nuclei of the liquid.
The main advantage of the new target-detector system is a gain in yield of six
orders of magnitude over conventional gas targets due to the higher mass
density of liquids. Also, the detector is practically insensitive to the
\gamma-ray beam itself, thus allowing it to detect only the products of the
nuclear reaction of interest. The first set of tests of a superheated target
with a narrow bandwidth \gamma-ray beam was completed and the results
demonstrate the feasibility of the scheme. The new data are successfully
described by an R-matrix model using published resonance parameters. With the
increase in luminosity of the next generation \gamma-ray beam facilities, the
measurement of thermonuclear rates in the stellar Gamow window would become
possible.
[16]
oai:arXiv.org:1204.3094 [pdf] - 565655
First dark matter search results from a 4-kg CF$_3$I bubble chamber
operated in a deep underground site
Behnke, E.;
Behnke, J.;
Brice, S. J.;
Broemmelsiek, D.;
Collar, J. I.;
Conner, A.;
Cooper, P. S.;
Crisler, M.;
Dahl, C. E.;
Fustin, D.;
Grace, E.;
Hall, J.;
Hu, M.;
Levine, I.;
Lippincott, W. H.;
Moan, T.;
Nania, T.;
Ramberg, E.;
Robinson, A. E.;
Sonnenschein, A.;
Szydagis, M.;
Vázquez-Jáuregui, E.
Submitted: 2012-04-13, last modified: 2012-09-19
New data are reported from the operation of a 4.0 kg CF$_{3}$I bubble chamber
in the 6800-foot-deep SNOLAB underground laboratory. The effectiveness of
ultrasound analysis in discriminating alpha-decay background events from single
nuclear recoils has been confirmed, with a lower bound of $>$99.3% rejection of
alpha-decay events. Twenty single nuclear recoil event candidates and three
multiple bubble events were observed during a total exposure of 553 kg-days
distributed over three different bubble nucleation thresholds. The effective
exposure for single bubble recoil-like events was 437.4 kg-days. A neutron
background internal to the apparatus, of known origin, is estimated to account
for five single nuclear recoil events and is consistent with the observed rate
of multiple bubble events. This observation provides world best direct
detection constraints on WIMP-proton spin-dependent scattering for WIMP masses
$>$20 GeV/c$^{2}$ and demonstrates significant sensitivity for spin-independent
interactions.
[17]
oai:arXiv.org:1105.5191 [pdf] - 1076883
Direct Search for Low Mass Dark Matter Particles with CCDs
Barreto, J.;
Cease, H.;
Diehl, H. T.;
Estrada, J.;
Flaugher, B.;
Harrison, N.;
Jones, J.;
Kilminster, B.;
Molina, J.;
Smith, J.;
Schwarz, T.;
Sonnenschein, A.
Submitted: 2011-05-25, last modified: 2012-04-02
A direct dark matter search is performed using fully-depleted
high-resistivity CCD detectors . Due to their low electronic readout noise (RMS
~ 7 eV) these devices operate with a very low detection threshold of 40 eV,
making the search for dark matter particles with low masses (~ 5 GeV) possible.
The results of an engineering run performed in a shallow underground site are
presented, demonstrating the potential of this technology in the low mass
region.
[18]
oai:arXiv.org:1008.3518 [pdf] - 326586
Improved Limits on Spin-Dependent WIMP-Proton Interactions from a Two
Liter CF$_3$I Bubble Chamber
Behnke, E.;
Behnke, J.;
Brice, S. J.;
Broemmelsiek, D.;
Collar, J. I.;
Cooper, P. S.;
Crisler, M.;
Dahl, C. E.;
Fustin, D.;
Hall, J.;
Hinnefeld, J. H.;
Hu, M.;
Levine, I.;
Ramberg, E.;
Shepherd, T.;
Sonnenschein, A.;
Szydagis, M.
Submitted: 2010-08-20, last modified: 2011-03-07
Data from the operation of a bubble chamber filled with 3.5 kg of CF$_{3}$I
in a shallow underground site are reported. An analysis of ultrasound signals
accompanying bubble nucleations confirms that alpha decays generate a
significantly louder acoustic emission than single nuclear recoils, leading to
an efficient background discrimination. Three dark matter candidate events were
observed during an effective exposure of 28.1 kg-day, consistent with a neutron
background. This observation provides the strongest direct detection constraint
to date on WIMP-proton spin-dependent scattering for WIMP masses $>20$
GeV/c$^{2}$.
[19]
oai:arXiv.org:0804.2886 [pdf] - 11873
Improved Spin-Dependent WIMP Limits from a Bubble Chamber
Behnke, E.;
Collar, J. I.;
Cooper, P. S.;
Crum, K.;
Crisler, M.;
Hu, M.;
Levine, I.;
Nakazawa, D.;
Nguyen, H.;
Odom, B.;
Ramberg, E.;
Rasmussen, J.;
Riley, N.;
Sonnenschein, A.;
Szydagis, M.;
Tschirhart, R.
Submitted: 2008-04-17
Bubble Chambers provided the dominant particle detection technology in
accelerator experiments for several decades, eventually falling into disuse
with the advent of other techniques. We report here on the first period of
operation of an ultra-clean, room-temperature bubble chamber containing 1.5 kg
of superheated CF$_{3}$I, a target maximally sensitive to spin-dependent and
-independent Weakly Interacting Massive Particle (WIMP) couplings. An exposure
in excess of 250 kg-days is obtained, with a live-time fraction reaching 80%.
This illustrates the ability to employ bubble chambers in a new realm, the
search for dark matter particles. Improved limits on the spin-dependent
WIMP-proton scattering cross section are extracted from this first period. An
extreme intrinsic insensitivity to the backgrounds commonly limiting these
experiments (a rejection factor for photon-induced electrons of $\sim10^{-10}$)
has been measured in operating conditions leading to the detection of
low-energy nuclear recoils such as those expected from WIMPs.
[20]
oai:arXiv.org:astro-ph/0605719 [pdf] - 82406
Deep Underground Science and Engineering Lab: S1 Dark Matter Working
Group
Akerib, D. S.;
Aprile, E.;
Baltz, E. A.;
Dragowsky, M. R.;
Gaitskell, R. J.;
Gondolo, P.;
Hime, A.;
Martoff, C. J.;
Mei, D. -M.;
Nelson, H.;
Sadoulet, B.;
Schnee, R. W.;
Sonnenschein, A. H.;
Strigari, L. E.
Submitted: 2006-05-30, last modified: 2007-04-23
A study of the current status of WIMP dark matter searches has been made in
the context of scientific and technical planning for a Deep Underground Science
and Engineering Laboratory (DUSEL) in the U.S. The table of contents follows:
1. Overview
2. WIMP Dark Matter: Cosmology, Astrophysics, and Particle Physics
3. Direct Detection of WIMPs
4. Indirect Detection of WIMPs
5. Dark Matter Candidates and New Physics in the Laboratory
6. Synergies with Other Sub-Fields
7. Direct Detection Experiments: Status and Future Prospects
8. Infrastructure
9. International Context
10. Summary and Outlook
11. Acknowledgments
[21]
oai:arXiv.org:astro-ph/0503398 [pdf] - 358287
Development of Bubble Chambers With Enhanced Stability and Sensitivity
to Low-Energy Nuclear Recoils
Bolte, W. J.;
Collar, J. I.;
Crisler, M.;
Hall, J.;
Holmgren, D.;
Nakazawa, D.;
Odom, B.;
O'Sullivan, K.;
Plunkett, R.;
Ramberg, E.;
Raskin, A.;
Sonnenschein, A.;
Vieira, J. D.
Submitted: 2005-03-17
The viability of using a Bubble Chamber for rare event searches and in
particular for the detection of dark matter particle candidates is considered.
Techniques leading to the deactivation of inhomogeneous nucleation centers and
subsequent enhanced stability in such a detector are described. Results from
prototype trials indicate that sensitivity to low-energy nuclear recoils like
those expected from Weakly Interacting Massive Particles can be obtained in
conditions of near total insensitivity to minimum ionizing backgrounds. An
understanding of the response of superheated heavy refrigerants to these
recoils is demonstrated within the context of existing theoretical models. We
comment on the prospects for the detection of supersymmetric dark matter
particles with a large $CF_{3}I$ chamber.
[22]
oai:arXiv.org:astro-ph/9712343 [pdf] - 99832
Preliminary Limits on the WIMP-Nucleon Cross Section from the Cryogenic
Dark Matter Search (CDMS)
Akerib, DS;
Barnes, PD;
Bauer, DA;
Brink, PL;
Cabrera, B;
Caldwell, DO;
Clarke, RM;
Da Silva, A;
Davies, AK;
Dougherty, BL;
Irwin, KD;
Gaitskell, RJ;
Golwala, SR;
Haller, EE;
Jochum, J;
Knowlton, WB;
Kuzminov, V;
Nam, SW;
Novikov, V;
Penn, MJ;
Perera, TA;
Ross, RR;
Sadoulet, B;
Schnee, RW;
Shutt, T;
Smith, A;
Sonnenschein, AH;
Spadafora, AL;
Stockwell, WK;
Yellin, S;
Young, BA
Submitted: 1997-12-30
We are conducting an experiment to search for WIMPs, or weakly-interacting
massive particles, in the galactic halo using terrestrial detectors. This
generic class of hypothetical particles, whose properties are similar to those
predicted by extensions of the standard model of particle physics, could
comprise the cold component of non-baryonic dark matter. We describe our
experiment, which is based on cooled germanium and silicon detectors in a
shielded low-background cryostat. The detectors achieve a high degree of
background rejection through the simultaneous measurement of the energy in
phonons and ionization. Using exposures on the order of one kilogram-day from
initial runs of our experiment, we have achieved (preliminary) upper limits on
the WIMP-nucleon cross section that are comparable to much longer runs of other
experiments.