Normalized to: Snowden-Ifft, D.
[1]
oai:arXiv.org:1809.06809 [pdf] - 1855616
New Concept for Electron Beam-Dump Experiment Utilizing Directional WIMP
Detector
Submitted: 2018-09-18, last modified: 2019-01-06
Light dark matter in the context of dark sector theories is an attractive
candidate for the dark matter thought to make up the bulk of the mass of our
universe. We explore here the possibility of using a low-pressure,
negative-ion, time projection chamber detector to search for light dark matter
behind the beam dump of an electron accelerator. The sensitivity of a 10 m long
detector is several orders of magnitude better than existing limits. This
sensitivity includes regions of parameter space where light dark matter is
predicted to have a required relic density consistent with measured dark matter
density. Backgrounds at shallow depth will need to be considered carefully.
However, several signatures exist, including a powerful directional signature,
which will allow a detection even in the presence of backgrounds.
[2]
oai:arXiv.org:1709.06219 [pdf] - 1648626
Study of Negative-Ion TPC Using {\mu}-PIC for Directional Dark Matter
Search
Ikeda, Tomonori;
Miuchi, Kentaro;
Ochi, Atsuhiko;
Yakabe, Ryota;
Hashimoto, Takashi;
Taishaku, Ryosuke;
Snowden-Ifft, Daniel P.;
Gauvreau, Jean-Luc;
Tanimori, Toru;
Takada, Atsushi;
Nakamura, Kiseki
Submitted: 2017-09-18
Negative-ion time projection chambers(TPCs) have been studied for low-rate
and high-resolution applications such as dark matter search experiments.
Recently, a full volume fiducialization in a self-triggering TPC was realized.
This innovative technology demonstrated a significant reduction in the
background with MWPC-TPCs. We studied negative-ion TPC using the {\mu}-PIC+GEM
system and obtained sufficient gas gain with CS$_{2}$gas and SF$_{6}$ gas at
low pressures. We expect an improvement in detector sensitivity and angular
resolution with better electronics.
[3]
oai:arXiv.org:1707.09431 [pdf] - 1586535
Measurement of directional range components of nuclear recoil tracks in
a fiducialised dark matter detector
Battat, J. B. R.;
Daw, E. J.;
Ezeribe, A. C.;
Gauvreau, J. -L.;
Harton, J. L.;
Lafler, R.;
Lee, E. R.;
Loomba, D.;
Lynch, W.;
Miller, E. H.;
Mouton, F.;
Paling, S.;
Phan, N.;
Robinson, M.;
Sadler, S. W.;
Scarff, A.;
Schuckman, F. G.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.
Submitted: 2017-07-28
We present results from the first measurement of axial range components of
fiducialized neutron induced nuclear recoil tracks using the DRIFT directional
dark matter detector. Nuclear recoil events are fiducialized in the DRIFT
experiment using temporal charge carrier separations between different species
of anions in 30:10:1 Torr of CS$_2$:CF$_4$:O$_2$ gas mixture. For this
measurement, neutron-induced nuclear recoil tracks were generated by exposing
the detector to $^{252}$Cf source from different directions. Using these
events, the sensitivity of the detector to the expected axial directional
signatures were investigated as the neutron source was moved from one detector
axis to another. Results obtained from these measurements show clear
sensitivity of the DRIFT detector to the axial directional signatures in this
fiducialization gas mode.
[5]
oai:arXiv.org:1701.00171 [pdf] - 1564000
Low Threshold Results and Limits from the DRIFT Directional Dark Matter
Detector
Battat, J. B. R.;
Ezeribe, A. C.;
Gauvreau, J. -L.;
Harton, J. L.;
Lafler, R.;
Law, E.;
Lee, E. R.;
Loomba, D.;
Lumnah, A.;
Miller, E. H.;
Monte, A.;
Mouton, F.;
Paling, S. M.;
Phan, N. S.;
Robinson, M.;
Sadler, S. W.;
Scarff, A.;
Schuckman, F. G.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Waldram, N.
Submitted: 2016-12-31, last modified: 2017-03-27
We present results from a 54.7 live-day shielded run of the DRIFT-IId
detector, the world's most sensitive, directional, dark matter detector.
Several improvements were made relative to our previous work including a lower
threshold for detection, a more robust analysis and a tenfold improvement in
our gamma rejection factor. After analysis, no events remain in our fiducial
region leading to an exclusion curve for spin-dependent WIMP-proton
interactions which reaches 0.28 pb at 100 GeV/c^2 a fourfold improvement on our
previous work. We also present results from a 45.4 live-day unshielded run of
the DRIFT-IId detector during which 14 nuclear recoil-like events were
observed. We demonstrate that the observed nuclear recoil rate of 0.31+/-0.08
events per day is consistent with detection of ambient, fast neutrons emanating
from the walls of the Boulby Underground Science Facility.
[6]
oai:arXiv.org:1610.02396 [pdf] - 1516330
Readout technologies for directional WIMP Dark Matter detection
Battat, J. B. R.;
Irastorza, I. G.;
Aleksandrov, A.;
Guler, M. Ali;
Asada, T.;
Baracchini, E.;
Billard, J.;
Bosson, G.;
Bourrion, O.;
Bouvier, J.;
Buonaura, A.;
Burdge, K.;
Cebrian, S.;
Colas, P.;
Consiglio, L.;
Dafni, T.;
D'Ambrosio, N.;
Deaconu, C.;
De Lellis, G.;
Descombes, T.;
Di Crescenzo, A.;
Di Marco, N.;
Druitt, G.;
Eggleston, R.;
Ferrer-Ribas, E.;
Fusayasu, T.;
Galan, J.;
Galati, G.;
Garcia, J. A.;
Garza, J. G.;
Gentile, V.;
Garcia-Sciveres, M.;
Giomataris, Y.;
Guerrero, N.;
Guillaudin, O.;
Harton, J.;
Hashimoto, T.;
Hedges, M. T.;
Iguaz, F.;
Ikeda, T.;
Jaegle, I.;
Kadyk, J. A.;
Katsuragawa, T.;
Komura, S.;
Kubo, H.;
Kuge, K.;
Lamblin, J.;
Lauria, A.;
Lee, E. R.;
Lewis, P.;
Leyton, M.;
Loomba, D.;
Lopez, J. P.;
Luzon, G.;
Mayet, F.;
Mirallas, H.;
Miuchi, K.;
Mizumoto, T.;
Mizumura, Y.;
Monacelli, P.;
Monroe, J.;
Montesi, M. C.;
Naka, T.;
Nakamura, K.;
Nishimura, H.;
Ochi, A.;
Papevangelou, T.;
Parker, J. D.;
Phan, N. S.;
Pupilli, F.;
Richer, J. P.;
Riffard, Q.;
Rosa, G.;
Santos, D.;
Sawano, T.;
Sekiya, H.;
Seong, I. S.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Sugiyama, A.;
Taishaku, R.;
Takada, A.;
Takeda, A.;
Tanaka, M.;
Tanimori, T.;
Thorpe, T. N.;
Tioukov, V.;
Tomita, H.;
Umemoto, A.;
Vahsen, S. E.;
Yamaguchi, Y.;
Yoshimoto, M.;
Zayas, E.
Submitted: 2016-10-06
The measurement of the direction of WIMP-induced nuclear recoils is a
compelling but technologically challenging strategy to provide an unambiguous
signature of the detection of Galactic dark matter. Most directional detectors
aim to reconstruct the dark-matter-induced nuclear recoil tracks, either in gas
or solid targets. The main challenge with directional detection is the need for
high spatial resolution over large volumes, which puts strong requirements on
the readout technologies. In this paper we review the various detector readout
technologies used by directional detectors. In particular, we summarize the
challenges, advantages and drawbacks of each approach, and discuss future
prospects for these technologies.
[8]
oai:arXiv.org:1607.01390 [pdf] - 1434217
Dark matter search in a Beam-Dump eXperiment (BDX) at Jefferson Lab
Battaglieri, M.;
Bersani, A.;
Caiffi, B.;
Celentano, A.;
De Vita, R.;
Fanchini, E.;
Marsicano, L.;
Musico, P.;
Osipenko, M.;
Panza, F.;
Ripani, M.;
Santopinto, E.;
Taiuti, M.;
Bellini, V.;
BondÃ, M.;
De Napoli, M.;
Mammoliti, F.;
Leonora, E.;
Randazzo, N.;
Russo, G.;
Sperduto, M.;
Sutera, C.;
Tortorici, F.;
Baltzell, N.;
Dalton, M.;
Freyberger, A.;
Girod, F. X.;
Kubarovsky, V.;
Pasyuk, E.;
Smith, E. S.;
Stepanyan, S.;
Ungaro, M.;
Whitlatch, T.;
Izaguirre, E.;
Krnjaic, G.;
Snowden-Ifft, D.;
Loomba, D.;
Carpinelli, M.;
Sipala, V.;
Schuster, P.;
Toro, N.;
Essig, R.;
Wood, M. H.;
Holtrop, M.;
Paremuzyan, R.;
De Cataldo, G.;
De Leo, R.;
Di Bari, D.;
Lagamba, L.;
Nappi, E.;
Perrino, R.;
Balossino, I.;
Barion, L.;
Ciullo, G.;
Contalbrigo, M.;
Lenisa, P.;
Movsisyan, A.;
Spizzo, F.;
Turisini, M.;
De Persio, F.;
Cisbani, E.;
Garibaldi, F.;
Meddi, F.;
Urciuoli, G. M.;
Hasch, D.;
Lucherini, V.;
Mirazita, M.;
Pisano, S.;
Simi, G.;
D'Angelo, A.;
Lanza, L.;
Rizzo, A.;
Schaerf, C.;
Zonta, I.;
Filippi, A.;
Fegan, S.;
Kunkel, M.;
Bashkanov, M.;
Beltrame, P.;
Murphy, A.;
Smith, G.;
Watts, D.;
Zachariou, N.;
Zana, L.;
Glazier, D.;
Ireland, D.;
McKinnon, B.;
Sokhan, D.;
Colaneri, L.;
Pereira, S. Anefalos;
Afanasev, A.;
Briscoe, B.;
Strakovsky, I.;
Kalantarians, N.;
Weinstein, L.;
Adhikari, K. P.;
Dunne, J. A.;
Dutta, D.;
Fassi, L. El;
Ye, L.;
Hicks, K.;
Cole, P.;
Dobbs, S.;
Fanelli, C.
Submitted: 2016-07-05
MeV-GeV dark matter (DM) is theoretically well motivated but remarkably
unexplored. This proposal presents the MeV-GeV DM discovery potential for a
$\sim$1 m$^3$ segmented CsI(Tl) scintillator detector placed downstream of the
Hall A beam-dump at Jefferson Lab, receiving up to 10$^{22}$
electrons-on-target (EOT) in 285 days. This experiment (Beam-Dump eXperiment or
BDX) would be sensitive to elastic DM-electron and to inelastic DM scattering
at the level of 10 counts per year, reaching the limit of the neutrino
irreducible background. The distinct signature of a DM interaction will be an
electromagnetic shower of few hundreds of MeV, together with a reduced activity
in the surrounding active veto counters. A detailed description of the DM
particle $\chi$ production in the dump and subsequent interaction in the
detector has been performed by means of Monte Carlo simulations. Different
approaches have been used to evaluate the expected backgrounds: the cosmogenic
background has been extrapolated from the results obtained with a prototype
detector running at INFN-LNS (Italy), while the beam-related background has
been evaluated by GEANT4 Monte Carlo simulations. The proposed experiment will
be sensitive to large regions of DM parameter space, exceeding the discovery
potential of existing and planned experiments in the MeV-GeV DM mass range by
up to two orders of magnitude.
[9]
oai:arXiv.org:1410.7821 [pdf] - 1250420
First background-free limit from a directional dark matter experiment:
results from a fully fiducialised DRIFT detector
Battat, J. B. R.;
Brack, J.;
Daw, E.;
Dorofeev, A.;
Ezeribe, A. C.;
Gauvreau, J. -L.;
Gold, M.;
Harton, J. L.;
Landers, J. M.;
Law, E.;
Lee, E. R.;
Loomba, D.;
Lumnah, A.;
Matthews, J. A. J.;
Miller, E. H.;
Monte, A.;
Mouton, F.;
Murphy, A. StJ.;
Paling, S. M.;
Phan, N.;
Robinson, M.;
Sadler, S. W.;
Scarff, A.;
Schuckman, F.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Telfer, S.;
Vahsen, S. E.;
Walker, D.;
Warner, D.;
Yuriev, L.
Submitted: 2014-10-28, last modified: 2015-07-23
The addition of O2 to gas mixtures in time projection chambers containing CS2
has recently been shown to produce multiple negative ions that travel at
slightly different velocities. This allows a measurement of the absolute
position of ionising events in the z (drift) direction. In this work, we apply
the z-fiducialisation technique to a directional dark matter search. In
particular, we present results from a 46.3 live-day source-free exposure of the
DRIFT-IId detector run in this completely new mode. With full-volume
fiducialisation, we have achieved the first background-free operation of a
directional detector. The resulting exclusion curve for spin-dependent
WIMP-proton interactions reaches 1.1 pb at 100 GeV/c2, a factor of 2 better
than our previous work. We describe the automated analysis used here, and argue
that detector upgrades, implemented after the acquisition of these data, will
bring an additional factor of >3 improvement in the near future.
[10]
oai:arXiv.org:1407.3938 [pdf] - 1215675
Radon in the DRIFT-II directional dark matter TPC: emanation, detection
and mitigation
Battat, J. B. R.;
Brack, J.;
Daw, E.;
Dorofeev, A.;
Ezeribe, A. C.;
Fox, J. R.;
Gauvreau, J. -L.;
Gold, M.;
Harmon, L. J.;
Harton, J. L.;
Landers, J. M.;
Lee, E. R.;
Loomba, D.;
Matthews, J. A. J.;
Miller, E. H.;
Monte, A.;
Murphy, A. StJ.;
Paling, S. M.;
Phan, N.;
Pipe, M.;
Robinson, M.;
Sadler, S. W.;
Scarff, A.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Telfer, S.;
Walker, D.;
Warner, D.;
Yuriev, L.
Submitted: 2014-07-15, last modified: 2014-08-25
Radon gas emanating from materials is of interest in environmental science
and also a major concern in rare event non-accelerator particle physics
experiments such as dark matter and double beta decay searches, where it is a
major source of background. Notable for dark matter experiments is the
production of radon progeny recoils (RPRs), the low energy (~100 keV) recoils
of radon daughter isotopes, which can mimic the signal expected from WIMP
interactions. Presented here are results of measurements of radon emanation
from detector materials in the 1 metre cubed DRIFT-II directional dark matter
gas time projection chamber experiment. Construction and operation of a radon
emanation facility for this work is described, along with an analysis to
continuously monitor DRIFT data for the presence of internal 222Rn and 218Po.
Applying this analysis to historical DRIFT data, we show how systematic
substitution of detector materials for alternatives, selected by this device
for low radon emanation, has resulted in a factor of ~10 reduction in internal
radon rates. Levels are found to be consistent with the sum from separate radon
emanation measurements of the internal materials and also with direct
measurement using an attached alpha spectrometer. The current DRIFT detector,
DRIFT-IId, is found to have sensitivity to 222Rn of 2.5 {\mu}Bq/l with current
analysis efficiency, potentially opening up DRIFT technology as a new tool for
sensitive radon assay of materials.
[11]
oai:arXiv.org:1404.2253 [pdf] - 934775
Background Assay and Rejection in DRIFT
Brack, Jeff;
Daw, Ed;
Dorofeev, Alexei;
Ezeribe, Anthony;
Gauvreau, Jean-Luc;
Gold, Michael;
Harton, John;
Lafler, Randy;
Lauer, Robert;
Lee, Eric R.;
Loomba, Dinesh;
Matthews, John;
Miller, Eric H.;
Monte, Alissa;
Murphy, Alex;
Paling, Sean;
Phan, Nguyen;
Sadler, Steve;
Scarff, Andrew;
Snowden-Ifft, Daniel;
Spooner, Neil;
Telfer, Sam;
Walker, Daniel;
Williams, Matt;
Yuriev, Leonid
Submitted: 2014-04-08
The DRIFT-IId dark matter detector is a m$^3$-scale low-pressure TPC with
directional sensitivity to WIMP-induced nuclear recoils. Its primary
backgrounds were due to alpha decays from contamination on the central cathode.
Efforts to reduce these backgrounds led to replacing the 20 \mu m wire central
cathode with one constructed from 0.9 \mu m aluminized mylar, which is almost
totally transparent to alpha particles. Detailed modeling of the nature and
origin of the remaining backgrounds led to an in-situ, ppt-sensitive assay of
alpha decay backgrounds from the central cathode. This led to further
improvements in the thin-film cathode resulting in over 2 orders of magnitude
reduction in backgrounds compared to the wire cathode. Finally, the addition of
O$_2$ to CS$_2$ gas was found to produce multiple species of electronegative
charge carriers, providing a method to determine the absolute position of
nuclear recoils and reject all known remaining backgrounds while retaining a
high efficiency for nuclear recoil detection.
[12]
oai:arXiv.org:1301.7145 [pdf] - 1159372
High Precision Measurements of Carbon Disulfide Negative Ion Mobility
and Diffusion
Submitted: 2013-01-30, last modified: 2013-12-12
High precision measurements were made of reduced mobility, lateral and
longitudinal diffusion of CS2- negative ions in 40 Torr CS2 and a 30 - 10 Torr
CS2 - CF4 gas mixture. The reduced mobility was found to be 353.0 +/- 0.5 cm^2
Torr / s V in CS2 and 397.4 +/- 0.7 cm^2 Torr / s V in the CS2 - CF4 gas
mixture at STP. The lateral diffusion temperatures for these two gases (295 +/-
15 K and 297 +/- 6 K) were found to be in good agreement with room temperature.
By contrast longitudinal diffusion temperature was found to be slightly
elevated (319 +/- 10 (stat) +/- 8 (sys) K and 310 +/- 20 (stat) +/- 6 (sys) K)
though given the errors, room temperature diffusion can not be ruled out. For
lateral diffusion significant capture distances (0.21 +/- 0.07 mm and 0.15 +/-
0.03 mm) were measured while for longitudinal diffusion the results were not
conclusive.
[13]
oai:arXiv.org:1110.0222 [pdf] - 967108
The DRIFT Dark Matter Experiments
Daw, E.;
Dorofeev, A.;
Fox, J. R.;
Gauvreau, J. -L.;
Ghag, C.;
Harmon, L. J.;
Harton, J. L.;
Gold, M.;
Lee, E. R.;
Loomba, D.;
Miller, E. H.;
Murphy, A. St. J.;
Paling, S. M.;
Landers, J. M.;
Phan, N.;
Pipe, M.;
Pushkin, K.;
Robinson, M.;
Sadler, S. W.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Walker, D.;
Warner, D.
Submitted: 2011-10-02
The current status of the DRIFT (Directional Recoil Identification From
Tracks) experiment at Boulby Mine is presented, including the latest limits on
the WIMP spin-dependent cross-section from 1.5 kg days of running with a
mixture of CS2 and CF4. Planned upgrades to DRIFT IId are detailed, along with
ongoing work towards DRIFT III, which aims to be the world's first 10 m3-scale
directional Dark Matter detector.
[14]
oai:arXiv.org:1010.3027 [pdf] - 345888
Spin-Dependent Limits from the DRIFT-IId Directional Dark Matter
Detector
Daw, E.;
Fox, J. R.;
Gauvreau, J. -L.;
Ghag, C.;
Harmon, L. J.;
Gold, M.;
Lee, E.;
Loomba, D.;
Miller, E.;
Murphy, A. StJ.;
Paling, S. M.;
Landers, J. M.;
Pipe, M.;
Pushkin, K.;
Robinson, M.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Walker, D.
Submitted: 2010-10-14, last modified: 2011-04-16
Data are presented from the DRIFT-IId detector housed in the Boulby mine in
northeast England. A 0.8 m^3 fiducial volume, containing partial pressures of
30 Torr CS2 and 10 Torr CF4, was exposed for a duration of 47.4 live-time days
with sufficient passive shielding to provide a neutron free environment within
the detector. The nuclear recoil events seen are consistent with a remaining
low level background from the decay of progeny of radon daughters attached to
the central cathode of the detector. However, energy depositions from such
events must drift across the entire width of the detector, and thus display
large diffusion upon reaching the readout planes of the device. Exploiting this
feature, it is shown to be possible to reject energy depositions from these
radon decay progeny events while still retaining sensitivity to nuclear recoil
events. The response of the detector is then interpreted, using the F nuclei
content of the gas, in terms of sensitivity to proton spin-dependent
WIMP-nucleon interactions, displaying a minimum in sensitivity cross section at
0.5 pb for a WIMP mass of 100 GeV/c^2.
[15]
oai:arXiv.org:0911.0323 [pdf] - 902277
The case for a directional dark matter detector and the status of
current experimental efforts
Ahlen, S.;
Afshordi, N.;
Battat, J. B. R.;
Billard, J.;
Bozorgnia, N.;
Burgos, S.;
Caldwell, T.;
Carmona, J. M.;
Cebrian, S.;
Colas, P.;
Dafni, T.;
Daw, E.;
Dujmic, D.;
Dushkin, A.;
Fedus, W.;
Ferrer, E.;
Finkbeiner, D.;
Fisher, P. H.;
Forbes, J.;
Fusayasu, T.;
Galan, J.;
Gamble, T.;
Ghag, C.;
Giomataris, I.;
Gold, M.;
Gomez, H.;
Gomez, M. E.;
Gondolo, P.;
Green, A.;
Grignon, C.;
Guillaudin, O.;
Hagemann, C.;
Hattori, K.;
Henderson, S.;
Higashi, N.;
Ida, C.;
Iguaz, F. J.;
Inglis, A.;
Irastorza, I. G.;
Iwaki, S.;
Kaboth, A.;
Kabuki, S.;
Kadyk, J.;
Kallivayalil, N.;
Kubo, H.;
Kurosawa, S.;
Kudryavtsev, V. A.;
Lamy, T.;
Lanza, R.;
Lawson, T. B.;
Lee, A.;
Lee, E. R.;
Lin, T.;
Loomba, D.;
Lopez, J.;
Luzon, G.;
Manobu, T.;
Martoff, J.;
Mayet, F.;
Mccluskey, B.;
Miller, E.;
Miuchi, K.;
Monroe, J.;
Morgan, B.;
Muna, D.;
Murphy, A. St. J.;
Naka, T.;
Nakamura, K.;
Nakamura, M.;
Nakano, T.;
Nicklin, G. G.;
Nishimura, H.;
Niwa, K.;
Paling, S. M.;
Parker, J.;
Petkov, A.;
Pipe, M.;
Pushkin, K.;
Robinson, M.;
Rodriguez, A.;
Rodriguez-Quintero, J.;
Sahin, T.;
Sanderson, R.;
Sanghi, N.;
Santos, D.;
Sato, O.;
Sawano, T.;
Sciolla, G.;
Sekiya, H.;
Slatyer, T. R.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Sugiyama, A.;
Takada, A.;
Takahashi, M.;
Takeda, A.;
Tanimori, T.;
Taniue, K.;
Tomas, A.;
Tomita, H.;
Tsuchiya, K.;
Turk, J.;
Tziaferi, E.;
Ueno, K.;
Vahsen, S.;
Vanderspek, R.;
Vergados, J.;
Villar, J. A.;
Wellenstein, H.;
Wolfe, I.;
Yamamoto, R. K.;
Yegoryan, H.
Submitted: 2009-11-01
We present the case for a dark matter detector with directional sensitivity.
This document was developed at the 2009 CYGNUS workshop on directional dark
matter detection, and contains contributions from theorists and experimental
groups in the field. We describe the need for a dark matter detector with
directional sensitivity; each directional dark matter experiment presents their
project's status; and we close with a feasibility study for scaling up to a one
ton directional detector, which would cost around $150M.
[16]
oai:arXiv.org:0809.1831 [pdf] - 16182
First measurement of the Head-Tail directional nuclear recoil signature
at energies relevant to WIMP dark matter searches
Burgos, S.;
Daw, E.;
Forbes, J.;
Ghag, C.;
Gold, M.;
Hagemann, C.;
Kudryavtsev, V. A.;
Lawson, T. B.;
Loomba, D.;
Majewski, P.;
Muna, D.;
Murphy, A. StJ.;
Nicklin, G. G.;
Paling, S. M.;
Petkov, A.;
Plank, S. J. S.;
Robinson, M.;
Sanghi, N.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Turk, J.;
Tziaferi, E.
Submitted: 2008-09-10
We present first evidence for the so-called Head-Tail asymmetry signature of
neutron-induced nuclear recoil tracks at energies down to 1.5 keV/amu using the
1m^3 DRIFT-IIc dark matter detector. This regime is appropriate for recoils
induced by Weakly Interacting Massive Particle (WIMPs) but one where the
differential ionization is poorly understood. We show that the distribution of
recoil energies and directions induced here by Cf-252 neutrons matches well
that expected from massive WIMPs. The results open a powerful new means of
searching for a galactic signature from WIMPs.
[17]
oai:arXiv.org:0807.3969 [pdf] - 14845
Measurement of the Range Component Directional Signature in a DRIFT-II
Detector using 252Cf Neutrons
Burgos, S.;
Daw, E.;
Forbes, J.;
Ghag, C.;
Gold, M.;
Hagemann, C.;
Kudryavtsev, V. A.;
Lawson, T. B.;
Loomba, D.;
Majewski, P.;
Muna, D.;
Murphy, A. St. J.;
Nicklin, G. G.;
Paling, S. M.;
Petkov, A.;
Plank, S. J. S.;
Robinson, M.;
Sanghi, N.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Turk, J.;
Tziaferi, E.
Submitted: 2008-07-24
The DRIFT collaboration utilizes low pressure gaseous detectors to search for
WIMP dark matter with directional signatures. A 252Cf neutron source was placed
on each of the principal axes of a DRIFT detector in order to test its ability
to measure directional signatures from the three components of very low energy
(~keV/amu) recoil ranges. A high trigger threshold and the event selection
procedure ensured that only sulfur recoils were analyzed. Sulfur recoils
produced in the CS2 target gas by the 252Cf source closely match those expected
from massive WIMP induced sulfur recoils. For each orientation of the source a
directional signal from the range components was observed, indicating that the
detector is directional along all 3 axes. An analysis of these results yields
an optimal orientation for DRIFT detectors when searching for a directional
signature from WIMPs. Additional energy dependent information is provided to
aid in understanding this effect.
[18]
oai:arXiv.org:astro-ph/9905074 [pdf] - 106400
The DRIFT Project: Searching for WIMPS with a Directional Detector
Submitted: 1999-05-06
A low pressure time projection chamber for the detection of WIMPs is
discussed. Discrimination against Compton electron background in such a device
should be very good, and directional information about the recoil atoms would
be obtainable. If a full 3-D reconstruction of the recoil tracks can be
achieved, Monte Carlo studies indicate that a WIMP signal could be identified
with high confidence from as few as 30 detected WIMP-nucleus scattering events.
[19]
oai:arXiv.org:astro-ph/9904064 [pdf] - 105961
Low Pressure Negative Ion Drift Chamber for Dark Matter Search
Submitted: 1999-04-05
Weakly Interacting Massive Particles (WIMPs) are an attractive candidate for
the dark matter thought to make up the bulk of the mass of our universe. We
explore here the possibility of using a low pressure negative ion drift chamber
to search for WIMPs. The innovation of drifting ions, instead of electrons,
allows the design of a detector with exceptional sensitivity to, background
rejection from, and signature of WIMPs.
[20]
oai:arXiv.org:astro-ph/9711039 [pdf] - 270490
Probing the structure of the cold dark matter halo with ancient mica
Submitted: 1997-11-05
Mica can store (for >1 Gy) etchable tracks caused by atoms recoiling from
WIMPs. Ancient mica is a directional detector despite the complex motions it
makes with respect to the WIMP "wind". We can exploit the properties of
directionality and long integration time to probe for structure in the dark
matter halo of our galaxy. We compute a sample of possible signals in mica for
a plausible model of halo structure.
[21]
oai:arXiv.org:astro-ph/9701215 [pdf] - 96488
Unique Signature of Dark Matter in Ancient Mica
Submitted: 1997-01-28
Mica can store (for >1 Gy) etchable tracks caused by atoms recoiling from
WIMPs. Because a background from fission neutrons will eventually limit this
technique, a unique signature for WIMPs in ancient mica is needed. Our motion
around the center of the Galaxy causes WIMPs, unlike neutrons, to enter the
mica from a preferred direction on the sky. Mica is a directional detector and
despite the complex rotations that natural mica crystals make with respect to
this WIMP ``wind,'' there is a substantial dependence of etch pit density on
present day mica orientation.