Normalized to: Sjoman, P.
[1]
oai:arXiv.org:1101.2038 [pdf] - 955981
Planck early results. III. First assessment of the Low Frequency
Instrument in-flight performance
Mennella, A.;
Bersanelli, M.;
Butler, R. C.;
Curto, A.;
Cuttaia, F.;
Davis, R. J.;
Dick, J.;
Frailis, M.;
Galeotta, S.;
Gregorio, A.;
Kurki-Suonio, H.;
Lawrence, C. R.;
Leach, S.;
Leahy, J. P.;
Lowe, S.;
Maino, D.;
Mandolesi, N.;
Maris, M.;
Martínez-González, E.;
Meinhold, P. R.;
Morgante, G.;
Pearson, D.;
Perrotta, F.;
Polenta, G.;
Poutanen, T.;
Sandri, M.;
Seiffert, M. D.;
Suur-Uski, A. -S.;
Tavagnacco, D.;
Terenzi, L.;
Tomasi, M.;
Valiviita, J.;
Villa, F.;
Watson, R.;
Wilkinson, A.;
Zacchei, A.;
Zonca, A.;
Aja, B.;
Artal, E.;
Baccigalupi, C.;
Banday, A. J.;
Barreiro, R. B.;
Bartlett, J. G.;
Bartolo, N.;
Battaglia, P.;
Bennett, K.;
Bonaldi, A.;
Bonavera, L.;
Borrill, J.;
Bouchet, F. R.;
Burigana, C.;
Cabella, P.;
Cappellini, B.;
Chen, X.;
Colombo, L.;
Cruz, M.;
Danese, L.;
D'Arcangelo, O.;
Davies, R. D.;
de Gasperis, G.;
de Rosa, A.;
de Zotti, G.;
Dickinson, C.;
Diego, J. M.;
Donzelli, S.;
Efstathiou, G.;
Enßlin, T. A.;
Eriksen, H. K.;
Falvella, M. C.;
Finelli, F.;
Foley, S.;
Franceschet, C.;
Franceschi, E.;
Gaier, T. C.;
Génova-Santos, R. T.;
George, D.;
Gómez, F.;
González-Nuevo, J.;
Górski, K. M.;
Gruppuso, A.;
Hansen, F. K.;
Herranz, D.;
Herreros, J. M.;
Hoyland, R. J.;
Hughes, N.;
Jewell, J.;
Jukkala, P.;
Juvela, M.;
Kangaslahti, P.;
Keihänen, E.;
Keskitalo, R.;
Kilpia, V. -H.;
Kisner, T. S.;
Knoche, J.;
Knox, L.;
Laaninen, M.;
Lähteenmäki, A.;
Lamarre, J. -M.;
Leonardi, R.;
León-Tavares, J.;
Leutenegger, P.;
Lilje, P. B.;
López-Caniego, M.;
Lubin, P. M.;
Malaspina, M.;
Marinucci, D.;
Massardi, M.;
Matarrese, S.;
Matthai, F.;
Melchiorri, A.;
Mendes, L.;
Miccolis, M.;
Migliaccio, M.;
Mitra, S.;
Moss, A.;
Natoli, P.;
Nesti, R.;
Nørgaard-Nielsen, H. U.;
Pagano, L.;
Paladini, R.;
Paoletti, D.;
Partridge, B.;
Pasian, F.;
Pettorino, V.;
Pietrobon, D.;
Pospieszalski, M.;
Prézeau, G.;
Prina, M.;
Procopio, P.;
Puget, J. -L.;
Quercellini, C.;
Rachen, J. P.;
Rebolo, R.;
Reinecke, M.;
Ricciardi, S.;
Robbers, G.;
Rocha, G.;
Roddis, N.;
Rubiño-Martín, J. A.;
Savelainen, M.;
Scott, D.;
Silvestri, R.;
Simonetto, A.;
Sjoman, P.;
Smoot, G. F.;
Sozzi, C.;
Stringhetti, L.;
Tauber, J. A.;
Tofani, G.;
Toffolatti, L.;
Tuovinen, J.;
Türler, M.;
Umana, G.;
Valenziano, L.;
Varis, J.;
Vielva, P.;
Vittorio, N.;
Wade, L. A.;
Watson, C.;
White, S. D. M.;
Winder, F.
Submitted: 2011-01-11, last modified: 2011-12-19
The scientific performance of the Planck Low Frequency Instrument (LFI) after
one year of in-orbit operation is presented. We describe the main optical
parameters and discuss photometric calibration, white noise sensitivity, and
noise properties. A preliminary evaluation of the impact of the main systematic
effects is presented. For each of the performance parameters, we outline the
methods used to obtain them from the flight data and provide a comparison with
pre-launch ground assessments, which are essentially confirmed in flight.
[2]
oai:arXiv.org:1005.2541 [pdf] - 1032478
Planck pre-launch status: calibration of the Low Frequency Instrument
flight model radiometers
Villa, F.;
Terenzi, L.;
Sandri, M.;
Meinhold, P.;
Poutanen, T.;
Battaglia, P.;
Franceschet, C.;
Hughes, N.;
Laaninen, M.;
Lapolla, P.;
Bersanelli, M.;
Butler, R. C.;
Cuttaia, F.;
D'Arcangelo, O.;
Frailis, M.;
Franceschi, E.;
Galeotta, S.;
Gregorio, A.;
Leonardi, R.;
Lowe, S. R.;
Mandolesi, N.;
Maris, M.;
Mendes, L.;
Mennella, A.;
Morgante, G.;
Stringhetti, L.;
Tomasi, M.;
Valenziano, L.;
Zacchei, A.;
Zonca, A.;
Aja, B.;
Artal, E.;
Balasini, M.;
Bernardino, T.;
Blackhurst, E.;
Boschini, L.;
Cappellini, B.;
Cavaliere, F.;
Colin, A.;
Colombo, F.;
Davis, R. J.;
De La Fuente, L.;
Edgeley, J.;
Gaier, T.;
Galtress, A.;
Hoyland, R.;
Jukkala, P.;
Kettle, D.;
Kilpia, V-H.;
Lawrence, C. R.;
Lawson, D.;
Leahy, J. P.;
Leutenegger, P.;
Levin, S.;
Maino, D.;
Malaspina, M.;
Mediavilla, A.;
Miccolis, M.;
Pagan, L.;
Pascual, J. P.;
Pasian, F.;
Pecora, M.;
Pospieszalski, M.;
Roddis, N.;
Salmon, M. J.;
Seiffert, M.;
Silvestri, R.;
Simonetto, A.;
Sjoman, P.;
Sozzi, C.;
Tuovinen, J.;
Varis, J.;
Wilkinson, A.;
Winder, F.
Submitted: 2010-05-14
The Low Frequency Instrument (LFI) on-board the ESA Planck satellite carries
eleven radiometer subsystems, called Radiometer Chain Assemblies (RCAs), each
composed of a pair of pseudo-correlation receivers. We describe the on-ground
calibration campaign performed to qualify the flight model RCAs and to measure
their pre-launch performances. Each RCA was calibrated in a dedicated
flight-like cryogenic environment with the radiometer front-end cooled to 20K
and the back-end at 300K, and with an external input load cooled to 4K. A
matched load simulating a blackbody at different temperatures was placed in
front of the sky horn to derive basic radiometer properties such as noise
temperature, gain, and noise performance, e.g. 1/f noise. The spectral response
of each detector was measured as was their susceptibility to thermal variation.
All eleven LFI RCAs were calibrated. Instrumental parameters measured in these
tests, such as noise temperature, bandwidth, radiometer isolation, and
linearity, provide essential inputs to the Planck-LFI data analysis.
[3]
oai:arXiv.org:1001.4661 [pdf] - 33165
Design, development, and verification of the Planck Low Frequency
Instrument 70 GHz Front-End and Back-End Modules
Varis, J.;
Hughes, N. J.;
Laaninen, M.;
Kilpia, V. -H.;
Jukkala, P.;
Tuovinen, J.;
Ovaska, S.;
Sjoman, P.;
Kangaslahti, P.;
Gaier, T.;
Hoyland, R.;
Meinhold, P.;
Mennella, A.;
Bersanelli, M.;
Butler, R. C.;
Cuttaia, F.;
Franceschi, E.;
Leonardi, R.;
Leutenegger, P.;
Malaspina, M.;
Mandolesi, N.;
Miccolis, M.;
Poutanen, T.;
Kurki-Suonio, H.;
Sandri, M.;
Stringhetti, L.;
Terenzi, L.;
Tomasi, M.;
Valenziano, L.
Submitted: 2010-01-26
70 GHz radiometer front-end and back-end modules for the Low Frequency
Instrument of the European Space Agencys Planck Mission were built and tested.
The operating principles and the design details of the mechanical structures
are described along with the key InP MMIC low noise amplifiers and phase
switches of the units. The units were tested in specially designed cryogenic
vacuum chambers capable of producing the operating conditions required for
Planck radiometers, specifically, a physical temperature of 20 K for the
front-end modules, 300 K for the back-end modules and 4 K for the reference
signal sources. Test results of the low noise amplifiers and phase switches,
the front and back-end modules, and the combined results of both modules are
discussed.
At 70 GHz frequency, the system noise temperature of the front and back end
is 28 K; the effective bandwidth 16 GHz, and the 1/f spectrum knee frequency is
38 mHz. The test results indicate state-of-the-art performance at 70 GHz
frequency and fulfil the Planck performance requirements.
[4]
oai:arXiv.org:1001.3321 [pdf] - 1024699
Planck pre-launch status: Design and description of the Low Frequency
Instrument
Bersanelli, M.;
Mandolesi, N.;
Butler, R. C.;
Mennella, A.;
Villa, F.;
Aja, B.;
Artal, E.;
Artina, E.;
Baccigalupi, C.;
Balasini, M.;
Baldan, G.;
Banday, A.;
Bastia, P.;
Battaglia, P.;
Bernardino, T.;
Blackhurst, E.;
Boschini, L.;
Burigana, C.;
Cafagna, G.;
Cappellini, B.;
Cavaliere, F.;
Colombo, F.;
Crone, G.;
Cuttaia, F.;
D'Arcangelo, O.;
Danese, L.;
Davies, R. D.;
Davis, R. J.;
De Angelis, L.;
De Gasperis, G. C.;
De La Fuente, L.;
De Rosa, A.;
De Zotti, G.;
Falvella, M. C.;
Ferrari, F.;
Ferretti, R.;
Figini, L.;
Fogliani, S.;
Franceschet, C.;
Franceschi, E.;
Gaier, T.;
Garavaglia, S.;
Gomez, F.;
Gorski, K.;
Gregorio, A.;
Guzzi, P.;
Herreros, J. M.;
Hildebrandt, S. R.;
Hoyland, R.;
Hughes, N.;
Janssen, M.;
Jukkala, P.;
Kettle, D.;
Kilpia, V. H.;
Laaninen, M.;
Lapolla, P. M.;
Lawrence, C. R.;
Leahy, J. P.;
Leonardi, R.;
Leutenegger, P.;
Levin, S.;
Lilje, P. B.;
Lowe, S. R.;
Lubin, D. Lawson P. M.;
Maino, D.;
Malaspina, M.;
Maris, M.;
Marti-Canales, J.;
Martinez-Gonzalez, E.;
Mediavilla, A.;
Meinhold, P.;
Miccolis, M.;
Morgante, G.;
Natoli, P.;
Nesti, R.;
Pagan, L.;
Paine, C.;
Partridge, B.;
Pascual, J. P.;
Pasian, F.;
Pearson, D.;
Pecora, M.;
Perrotta, F.;
Platania, P.;
Pospieszalski, M.;
Poutanen, T.;
Prina, M.;
Rebolo, R.;
Roddis, N.;
Rubino-Martin, J. A.;
Salmon, n M. J.;
Sandri, M.;
Seiffert, M.;
Silvestri, R.;
Simonetto, A.;
Sjoman, P.;
Smoot, G. F.;
Sozzi, C.;
Stringhetti, L.;
Taddei, E.;
Tauber, J.;
Terenzi, L.;
Tomasi, M.;
Tuovinen, J.;
Valenziano, L.;
Varis, J.;
Vittorio, N.;
Wade, L. A.;
Wilkinson, A.;
Winder, F.;
Zacchei, A.;
Zonca, A.
Submitted: 2010-01-19
In this paper we present the Low Frequency Instrument (LFI), designed and
developed as part of the Planck space mission, the ESA program dedicated to
precision imaging of the cosmic microwave background (CMB). Planck-LFI will
observe the full sky in intensity and polarisation in three frequency bands
centred at 30, 44 and 70 GHz, while higher frequencies (100-850 GHz) will be
covered by the HFI instrument. The LFI is an array of microwave radiometers
based on state-of-the-art Indium Phosphide cryogenic HEMT amplifiers
implemented in a differential system using blackbody loads as reference
signals. The front-end is cooled to 20K for optimal sensitivity and the
reference loads are cooled to 4K to minimise low frequency noise. We provide an
overview of the LFI, discuss the leading scientific requirements and describe
the design solutions adopted for the various hardware subsystems. The main
drivers of the radiometric, optical and thermal design are discussed, including
the stringent requirements on sensitivity, stability, and rejection of
systematic effects. Further details on the key instrument units and the results
of ground calibration are provided in a set of companion papers.