sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Sisti, M.

Normalized to: Sisti, M.

4 article(s) in total. 143 co-authors, from 1 to 2 common article(s). Median position in authors list is 18,0.

[1]  oai:arXiv.org:1810.03957  [pdf] - 2128092
Electron-only magnetic reconnection in plasma turbulence
Comments: 20 pages, 8 figures; Accepted for publication
Submitted: 2018-10-09, last modified: 2020-07-06
Hybrid-Vlasov-Maxwell simulations of magnetized plasma turbulence including non-linear electron-inertia effects in a generalized Ohm's law are presented. When fluctuation energy is injected on scales sufficiently close to ion-kinetic scales, the ions efficiently become de-magnetized and electron-scale current sheets largely dominate the distribution of the emerging current structures, in contrast to the usual picture, where a full hierarchy of structure sizes is generally observed. These current sheets are shown to be the sites of electron-only reconnection (e-rec), in which the usual electron exhausts are unaccompanied by ion outflows and which are in qualitative agreement with those recently observed by MMS in the Earth's turbulent magnetosheath, downstream of the bow shock. Some features of the e-rec phenomenology are shown to be consistent with an electron magnetohydrodynamic description. Simulations suggest that this regime of collisionless reconnection may be found in turbulent systems where plasma processes, such as micro-instabilities and/or shocks, overpower the more customary turbulent cascade by directly injecting energy close to the ion-kinetic scales.
[2]  oai:arXiv.org:1405.3782  [pdf] - 862787
Search for axioelectric effect of solar axions using BGO scintillating bolometer
Comments: 5 pages, 3 figures
Submitted: 2014-05-15, last modified: 2014-09-08
A search for axioelectric absorption of solar axions produced in the $ p + d \rightarrow {^3\rm{He}}+\gamma~(5.5~ \rm{MeV})$ reactions has been performed with a BGO detector placed in a low-background setup. A model-independent limit on an axion-nucleon and axion-electron coupling constant has been obtained: $| g_{Ae}\times g_{AN}^3|< 1.9\times 10^{-10}$ for 90% confidence level. The constrains of the axion-electron coupling have been obtained for hadronic axion with masses in (0.1 - 1) MeV range: $|g_{Ae}| \leq (0.96 - 8.2)\times 10^{-8}$.
[3]  oai:arXiv.org:1209.2519  [pdf] - 621874
The low energy spectrum of TeO2 bolometers: results and dark matter perspectives for the CUORE-0 and CUORE experiments
Alessandria, F.; Ardito, R.; Artusa, D. R.; Avignone, F. T.; Azzolini, O.; Balata, M.; Banks, T. I.; Bari, G.; Beeman, J.; Bellini, F.; Bersani, A.; Biassoni, M.; Bloxham, T.; Brofferio, C.; Bucci, C.; Cai, X. Z.; Canonica, L.; Capelli, S.; Carbone, L.; Cardani, L.; Carrettoni, M.; Casali, N.; Chott, N.; Clemenza, M.; Cosmelli, C.; Cremonesi, O.; Creswick, R. J.; Dafinei, I.; Dally, A.; Datskov, V.; De Biasi, A.; Decowski, M. P.; Deninno, M. M.; Di Domizio, S.; di Vacri, M. L.; Ejzak, L.; Faccini, R.; Fang, D. Q.; Farach, H. A.; Ferri, E.; Ferroni, F.; Fiorini, E.; Franceschi, M. A.; Freedman, S. J.; Frossati, G.; Fujikawa, B. K.; Giachero, A.; Gironi, L.; Giuliani, A.; Goett, J. J.; Gorla, P.; Gotti, C.; Guardincerri, E.; Gutierrez, T. D.; Haller, E. E.; Han, K.; Heeger, K. M.; Huang, H. Z.; Kadel, R.; Kazkaz, K.; Keppel, G.; Kogler, L.; Kolomensky, Yu. G.; Lenz, D.; Li, Y. L.; Ligi, C.; Liu, X.; Ma, Y. G.; Maiano, C.; Maino, M.; Martinez, M.; Maruyama, R. H.; Moggi, N.; Morganti, S.; Napolitano, T.; Newman, S.; Nisi, S.; Nones, C.; Norman, E. B.; Nucciotti, A.; Orio, F.; Orlandi, D.; Ouellet, J. L.; Pallavicini, M.; Palmieri, V.; Pattavina, L.; Pavan, M.; Pedretti, M.; Pessina, G.; Pirro, S.; Previtali, E.; Rampazzo, V.; Rimondi, F.; Rosenfeld, C.; Rusconi, C.; Sangiorgio, S.; Scielzo, N. D.; Sisti, M.; Smith, A. R.; Stivanello, F.; Taffarello, L.; Tenconi, M.; Tian, W. D.; Tomei, C.; Trentalange, S.; Ventura, G.; Vignati, M.; Wang, B. S.; Wang, H. W.; Whitten, C. A.; Wise, y T.; Woodcraft, A.; Zanotti, L.; Zarra, C.; Zhu, B. X.; Zucchelli, S.
Comments: 9 pages, 10 figures
Submitted: 2012-09-12, last modified: 2013-02-01
We collected 19.4 days of data from four 750 g TeO2 bolometers, and in three of them we were able to set the energy threshold around 3 keV using a new analysis technique. We found a background rate ranging from 25 cpd/keV/kg at 3 keV to 2 cpd/keV/kg at 25 keV, and a peak at 4.7 keV. The origin of this peak is presently unknown, but its presence is confirmed by a reanalysis of 62.7 kg.days of data from the finished CUORICINO experiment. Finally, we report the expected sensitivities of the CUORE0 (52 bolometers) and CUORE (988 bolometers) experiments to a WIMP annual modulation signal.
[4]  oai:arXiv.org:physics/0504151  [pdf] - 119090
Fracture Processes Observed with A Cryogenic Detector
Comments: Fig 4 and surrounding discussion changed. References added, langauge clarified, with greater stress on sensitivity and total energy detection. Error in metadata fixed
Submitted: 2005-04-21, last modified: 2006-03-21
In the early stages of running of the CRESST dark matter search using sapphire detectors at very low temperature, an unexpectedly high rate of signal pulses appeared. Their origin was finally traced to fracture events in the sapphire due to the very tight clamping of the detectors. During extensive runs the energy and time of each event was recorded, providing large data sets for such phenomena. We believe this is the first time the energy release in fracture has been directly and accurately measured on a microscopic event-by-event basis. The energy threshold corresponds to the breaking of only a few hundred covalent bonds, a sensitivity some orders of magnitude greater than that of previous technique. We report some features of the data, including energy distributions, waiting time distributions, autocorrelations and the Hurst exponent. The energy distribution appear to follow a power law, $dN/dE\propto E^{-\beta}$, similar to the power law for earthquake magnitudes, and after appropriate translation, with a similar exponent. In the time domain,the waiting time $w$ or gap distribution between events has a power law behavior at small $w$ and an exponential fall-off at large $w,$ and can be fit $\propto w^{-\alpha}e^{-w/w_0}$. The autocorrelation function shows time correlations lasting for substantial parts of an hour. An asymmetry is found around large events, with higher count rates after, as opposed to before,the large event .