Normalized to: Simonetto, A.
[1]
oai:arXiv.org:2001.02336 [pdf] - 2037546
Permittivity and permeability of epoxy-magnetite powder composites at
microwave frequencies
Submitted: 2020-01-07
Radio, millimetre and sub-millimetre astronomy experiments as well as remote
sensing applications often require castable absorbers with well known
electromagnetic properties to design and realize calibration targets. In this
context, we fabricated and characterized two samples using different ratios of
two easily commercially available materials: epoxy (Stycast 2850FT) and
magnetite ($\mathrm{Fe_{3}O_{4}}$) powder. We performed transmission and
reflection measurements from 7 GHz up to 170 GHz with a VNA equipped with a
series of standard horn antennas. Using an empirical model we analysed the data
to extract complex permittivity and permeability from transmission data; then
we used reflection data to validate the results. In this paper we present the
sample fabrication procedure, analysis method, parameter extraction pipeline,
and results for two samples with different epoxy-powder mass ratios.
[2]
oai:arXiv.org:1101.2038 [pdf] - 955981
Planck early results. III. First assessment of the Low Frequency
Instrument in-flight performance
Mennella, A.;
Bersanelli, M.;
Butler, R. C.;
Curto, A.;
Cuttaia, F.;
Davis, R. J.;
Dick, J.;
Frailis, M.;
Galeotta, S.;
Gregorio, A.;
Kurki-Suonio, H.;
Lawrence, C. R.;
Leach, S.;
Leahy, J. P.;
Lowe, S.;
Maino, D.;
Mandolesi, N.;
Maris, M.;
Martínez-González, E.;
Meinhold, P. R.;
Morgante, G.;
Pearson, D.;
Perrotta, F.;
Polenta, G.;
Poutanen, T.;
Sandri, M.;
Seiffert, M. D.;
Suur-Uski, A. -S.;
Tavagnacco, D.;
Terenzi, L.;
Tomasi, M.;
Valiviita, J.;
Villa, F.;
Watson, R.;
Wilkinson, A.;
Zacchei, A.;
Zonca, A.;
Aja, B.;
Artal, E.;
Baccigalupi, C.;
Banday, A. J.;
Barreiro, R. B.;
Bartlett, J. G.;
Bartolo, N.;
Battaglia, P.;
Bennett, K.;
Bonaldi, A.;
Bonavera, L.;
Borrill, J.;
Bouchet, F. R.;
Burigana, C.;
Cabella, P.;
Cappellini, B.;
Chen, X.;
Colombo, L.;
Cruz, M.;
Danese, L.;
D'Arcangelo, O.;
Davies, R. D.;
de Gasperis, G.;
de Rosa, A.;
de Zotti, G.;
Dickinson, C.;
Diego, J. M.;
Donzelli, S.;
Efstathiou, G.;
Enßlin, T. A.;
Eriksen, H. K.;
Falvella, M. C.;
Finelli, F.;
Foley, S.;
Franceschet, C.;
Franceschi, E.;
Gaier, T. C.;
Génova-Santos, R. T.;
George, D.;
Gómez, F.;
González-Nuevo, J.;
Górski, K. M.;
Gruppuso, A.;
Hansen, F. K.;
Herranz, D.;
Herreros, J. M.;
Hoyland, R. J.;
Hughes, N.;
Jewell, J.;
Jukkala, P.;
Juvela, M.;
Kangaslahti, P.;
Keihänen, E.;
Keskitalo, R.;
Kilpia, V. -H.;
Kisner, T. S.;
Knoche, J.;
Knox, L.;
Laaninen, M.;
Lähteenmäki, A.;
Lamarre, J. -M.;
Leonardi, R.;
León-Tavares, J.;
Leutenegger, P.;
Lilje, P. B.;
López-Caniego, M.;
Lubin, P. M.;
Malaspina, M.;
Marinucci, D.;
Massardi, M.;
Matarrese, S.;
Matthai, F.;
Melchiorri, A.;
Mendes, L.;
Miccolis, M.;
Migliaccio, M.;
Mitra, S.;
Moss, A.;
Natoli, P.;
Nesti, R.;
Nørgaard-Nielsen, H. U.;
Pagano, L.;
Paladini, R.;
Paoletti, D.;
Partridge, B.;
Pasian, F.;
Pettorino, V.;
Pietrobon, D.;
Pospieszalski, M.;
Prézeau, G.;
Prina, M.;
Procopio, P.;
Puget, J. -L.;
Quercellini, C.;
Rachen, J. P.;
Rebolo, R.;
Reinecke, M.;
Ricciardi, S.;
Robbers, G.;
Rocha, G.;
Roddis, N.;
Rubiño-Martín, J. A.;
Savelainen, M.;
Scott, D.;
Silvestri, R.;
Simonetto, A.;
Sjoman, P.;
Smoot, G. F.;
Sozzi, C.;
Stringhetti, L.;
Tauber, J. A.;
Tofani, G.;
Toffolatti, L.;
Tuovinen, J.;
Türler, M.;
Umana, G.;
Valenziano, L.;
Varis, J.;
Vielva, P.;
Vittorio, N.;
Wade, L. A.;
Watson, C.;
White, S. D. M.;
Winder, F.
Submitted: 2011-01-11, last modified: 2011-12-19
The scientific performance of the Planck Low Frequency Instrument (LFI) after
one year of in-orbit operation is presented. We describe the main optical
parameters and discuss photometric calibration, white noise sensitivity, and
noise properties. A preliminary evaluation of the impact of the main systematic
effects is presented. For each of the performance parameters, we outline the
methods used to obtain them from the flight data and provide a comparison with
pre-launch ground assessments, which are essentially confirmed in flight.
[3]
oai:arXiv.org:1107.1157 [pdf] - 382247
W-band prototype of platelet feed-horn array for CMB polarisation
measurements
Del Torto, Francesco;
Bersanelli, Marco;
Cavaliere, Francesco;
De Rosa, Adriano;
D'Arcangelo, Ocleto;
Franceschet, Cristian;
Gervasi, Massimo;
Mennella, Aniello;
Pagana, Enrico;
Simonetto, Alessandro;
Tartari, Andrea;
Villa, Fabrizio;
Zannoni, Mario
Submitted: 2011-07-06
We present the design and performance of a 2x2 prototype array of corrugated
feed-horns in W-band. The module is fabricated using a so-called "platelet"
technique by milling Aluminum plates. This technique is suitable for low-cost
and scalable high performance applications. Room temperature Return Loss
measurements show a low (<-30 dB) reflection over a 30% bandwidth with a
maximum matching of -42 dB at 100 GHz for all four antennas. Beam pattern
measurements indicate good repeatability and a low (-25 dB) sidelobe and
crosspolarisation levels. This work is particularly relevant for future Cosmic
Microwave Background polarisation measurements, which require large microwave
cryogenic detector arrays coupled to high performance corrugated feed horns.
[4]
oai:arXiv.org:1101.2022 [pdf] - 1521890
Planck Early Results: The Planck mission
Planck Collaboration;
Ade, P. A. R.;
Aghanim, N.;
Arnaud, M.;
Ashdown, M.;
Aumont, J.;
Baccigalupi, C.;
Baker, M.;
Balbi, A.;
Banday, A. J.;
Barreiro, R. B.;
Bartlett, J. G.;
Battaner, E.;
Benabed, K.;
Bennett, K.;
Benoît, A.;
Bernard, J. -P.;
Bersanelli, M.;
Bhatia, R.;
Bock, J. J.;
Bonaldi, A.;
Bond, J. R.;
Borrill, J.;
Bouchet, F. R.;
Bradshaw, T.;
Bremer, M.;
Bucher, M.;
Burigana, C.;
Butler, R. C.;
Cabella, P.;
Cantalupo, C. M.;
Cappellini, B.;
Cardoso, J. -F.;
Carr, R.;
Casale, M.;
Catalano, A.;
Cayón, L.;
Challinor, A.;
Chamballu, A.;
Charra, J.;
Chary, R. -R.;
Chiang, L. -Y;
Chiang, C.;
Christensen, P. R.;
Clements, D. L.;
Colombi, S.;
Couchot, F.;
Coulais, A.;
Crill, B. P.;
Crone, G.;
Crook, M.;
Cuttaia, F.;
Danese, L.;
D'Arcangelo, O.;
Davies, R. D.;
Davis, R. J.;
de Bernardis, P.;
de Bruin, J.;
de Gasperis, G.;
de Rosa, A.;
de Zotti, G.;
Delabrouille, J.;
Delouis, J. -M.;
Dèsert, F. -X.;
Dick, J.;
Dickinson, C.;
Dolag, K.;
Dole, H.;
Donzelli, S.;
Dorè, O.;
Dörl, U.;
Douspis, M.;
Dupac, X.;
Efstathiou, G.;
Enfllin, T. A.;
Eriksen, H. K.;
Finelli, F.;
Foley, S.;
Forni, O.;
Fosalba, P.;
Frailis, M.;
Franceschi, E.;
Freschi, M.;
Gaier, T. C.;
Galeotta, S.;
Gallegos, J.;
Gandolfo, B.;
Ganga, K.;
Giard, M.;
Giardino, G.;
Gienger, G.;
Giraud-Hèraud, Y.;
González, J.;
González-Nuevo, J.;
Górski, K. M.;
Gratton, S.;
Gregorio, A.;
Gruppuso, A.;
Guyot, G.;
Haissinski, J.;
Hansen, F. K.;
Harrison, D.;
Helou, G.;
Henrot-Versillè, S.;
Hernández-Monteagudo, C.;
Herranz, D.;
Hildebrandt, S. R.;
Hivon, E.;
Hobson, M.;
Holmes, W. A.;
Hornstrup, A.;
Hovest, W.;
Hoyland, R. J.;
Huffenberger, K. M.;
Jaffe, A. H.;
Jagemann, T.;
Jones, W. C.;
Juillet, J. J.;
Juvela, M.;
Kangaslahti, P.;
Keihänen, E.;
Keskitalo, R.;
Kisner, T. S.;
Kneissl, R.;
Knox, L.;
Krassenburg, M.;
Kurki-Suonio, H.;
Lagache, G.;
Lähteenmäki, A.;
Lamarre, J. -M.;
Lange, A. E.;
Lasenby, A.;
Laureijs, R. J.;
Lawrence, C. R.;
Leach, S.;
Leahy, J. P.;
Leonardi, R.;
Leroy, C.;
Lilje, P. B.;
Linden-Vørnle, M.;
López-Caniego, M.;
Lowe, S.;
Lubin, P. M.;
Macìas-Pèrez, J. F.;
Maciaszek, T.;
MacTavish, C. J.;
Maffei, B.;
Maino, D.;
Mandolesi, N.;
Mann, R.;
Maris, M.;
Martìnez-González, E.;
Masi, S.;
Massardi, M.;
Matarrese, S.;
Matthai, F.;
Mazzotta, P.;
McDonald, A.;
McGehee, P.;
Meinhold, P. R.;
Melchiorri, A.;
Melin, J. -B.;
Mendes, L.;
Mennella, A.;
Mevi, C.;
Miniscalco, R.;
Mitra, S.;
Miville-Deschínes, M. -A.;
Moneti, A.;
Montier, L.;
Morgante, G.;
Morisset, N.;
Mortlock, D.;
Munshi, D.;
Murphy, A.;
Naselsky, P.;
Natoli, P.;
Netterfield, C. B.;
Nørgaard-Nielsen, H. U.;
Noviello, F.;
Novikov, D.;
Novikov, I.;
O'Dwyer, I. J.;
Ortiz, I.;
Osborne, S.;
Osuna, P.;
Oxborrow, C. A.;
Pajot, F.;
Paladini, R.;
Partridge, B.;
Pasian, F.;
Passvogel, T.;
Patanchon, G.;
Pearson, D.;
Pearson, T. J.;
Perdereau, O.;
Perotto, L.;
Perrotta, F.;
Piacentini, F.;
Piat, M.;
Pierpaoli, E.;
Plaszczynski, S.;
Platania, P.;
Pointecouteau, E.;
Polenta, G.;
Ponthieu, N.;
Popa, L.;
Poutanen, T.;
Prèzeau, G.;
Prunet, S.;
Puget, J. -L.;
Rachen, J. P.;
Reach, W. T.;
Rebolo, R.;
Reinecke, M.;
Reix, J. -M.;
Renault, C.;
Ricciardi, S.;
Riller, T.;
Ristorcelli, I.;
Rocha, G.;
Rosset, C.;
Rowan-Robinson, M.;
Rubiñ-Martìn, J. A.;
Rusholme, B.;
Salerno, E.;
Sandri, M.;
Santos, D.;
Savini, G.;
Schaefer, B. M.;
Scott, D.;
Seiffert, M. D.;
Shellard, P.;
Simonetto, A.;
Smoot, G. F.;
Sozzi, C.;
Starck, J. -L.;
Sternberg, J.;
Stivoli, F.;
Stolyarov, V.;
Stompor, R.;
Stringhetti, L.;
Sudiwala, R.;
Sunyaev, R.;
Sygnet, J. -F.;
Tapiador, D.;
Tauber, J. A.;
Tavagnacco, D.;
Taylor, D.;
Terenzi, L.;
Texier, D.;
Toffolatti, L.;
Tomasi, M.;
Torre, J. -P.;
Tristram, M.;
Tuovinen, J.;
Türler, M.;
Tuttlebee, M.;
Umana, G.;
Valenziano, L.;
Valiviita, J.;
Varis, J.;
Vibert, L.;
Vielva, P.;
Villa, F.;
Vittorio, N.;
Wade, L. A.;
Wandelt, B. D.;
Watson, C.;
White, S. D. M.;
White, M.;
Wilkinson, A.;
Yvon, D.;
Zacchei, A.;
Zonca, A.
Submitted: 2011-01-11, last modified: 2011-06-16
The European Space Agency's Planck satellite was launched on 14 May 2009, and
has been surveying the sky stably and continuously since 13 August 2009. Its
performance is well in line with expectations, and it will continue to gather
scientific data until the end of its cryogenic lifetime. We give an overview of
the history of Planck in its first year of operations, and describe some of the
key performance aspects of the satellite. This paper is part of a package
submitted in conjunction with Planck's Early Release Compact Source Catalogue,
the first data product based on Planck to be released publicly. The package
describes the scientific performance of the Planck payload, and presents
results on a variety of astrophysical topics related to the sources included in
the Catalogue, as well as selected topics on diffuse emission.
[5]
oai:arXiv.org:1005.2541 [pdf] - 1032478
Planck pre-launch status: calibration of the Low Frequency Instrument
flight model radiometers
Villa, F.;
Terenzi, L.;
Sandri, M.;
Meinhold, P.;
Poutanen, T.;
Battaglia, P.;
Franceschet, C.;
Hughes, N.;
Laaninen, M.;
Lapolla, P.;
Bersanelli, M.;
Butler, R. C.;
Cuttaia, F.;
D'Arcangelo, O.;
Frailis, M.;
Franceschi, E.;
Galeotta, S.;
Gregorio, A.;
Leonardi, R.;
Lowe, S. R.;
Mandolesi, N.;
Maris, M.;
Mendes, L.;
Mennella, A.;
Morgante, G.;
Stringhetti, L.;
Tomasi, M.;
Valenziano, L.;
Zacchei, A.;
Zonca, A.;
Aja, B.;
Artal, E.;
Balasini, M.;
Bernardino, T.;
Blackhurst, E.;
Boschini, L.;
Cappellini, B.;
Cavaliere, F.;
Colin, A.;
Colombo, F.;
Davis, R. J.;
De La Fuente, L.;
Edgeley, J.;
Gaier, T.;
Galtress, A.;
Hoyland, R.;
Jukkala, P.;
Kettle, D.;
Kilpia, V-H.;
Lawrence, C. R.;
Lawson, D.;
Leahy, J. P.;
Leutenegger, P.;
Levin, S.;
Maino, D.;
Malaspina, M.;
Mediavilla, A.;
Miccolis, M.;
Pagan, L.;
Pascual, J. P.;
Pasian, F.;
Pecora, M.;
Pospieszalski, M.;
Roddis, N.;
Salmon, M. J.;
Seiffert, M.;
Silvestri, R.;
Simonetto, A.;
Sjoman, P.;
Sozzi, C.;
Tuovinen, J.;
Varis, J.;
Wilkinson, A.;
Winder, F.
Submitted: 2010-05-14
The Low Frequency Instrument (LFI) on-board the ESA Planck satellite carries
eleven radiometer subsystems, called Radiometer Chain Assemblies (RCAs), each
composed of a pair of pseudo-correlation receivers. We describe the on-ground
calibration campaign performed to qualify the flight model RCAs and to measure
their pre-launch performances. Each RCA was calibrated in a dedicated
flight-like cryogenic environment with the radiometer front-end cooled to 20K
and the back-end at 300K, and with an external input load cooled to 4K. A
matched load simulating a blackbody at different temperatures was placed in
front of the sky horn to derive basic radiometer properties such as noise
temperature, gain, and noise performance, e.g. 1/f noise. The spectral response
of each detector was measured as was their susceptibility to thermal variation.
All eleven LFI RCAs were calibrated. Instrumental parameters measured in these
tests, such as noise temperature, bandwidth, radiometer isolation, and
linearity, provide essential inputs to the Planck-LFI data analysis.
[6]
oai:arXiv.org:1001.4778 [pdf] - 33192
Planck-LFI: Design and Performance of the 4 Kelvin Reference Load Unit
Valenziano, Luca;
Cuttaia, Francesco;
De Rosa, Adriano;
Terenzi, Luca;
Brighenti, Alberto;
Cazzola, GianPaolo;
Garbesi, Anna;
Mariotti, Sergio;
Orsi, Giordano;
Pagan, Luca;
Cavaliere, Francesco;
Lapini, Roberto;
Biggi, Matteo;
Panagin, Enzo;
Paola, Battaglia;
Butler, Chris;
Bersanelli, Marco;
D'Arcangelo, Ocleto;
Levin, Steve;
Mandolesi, Nazzareno;
Mennella, Aniello;
Morgante, Gianluca;
Morigi, Gabriele;
Sandri, Maura;
Simonetto, Alessandro;
Tomasi, Maurizio;
Villa, Fabrizio;
Frailis, Marco;
Galeotta, Samuele;
Gregorio, Anna;
Leonardi, Rodrigo;
Lowe, Stuart;
Maris, Michele;
Meinhold, Peter;
Mendes, Luis;
Stringhetti, Luca;
Zonca, Andrea;
Zacchei, Andrea
Submitted: 2010-01-26
The LFI radiometers use a pseudo-correlation design where the signal from the
sky is continuously compared with a stable reference signal, provided by a
cryogenic reference load system. The reference unit is composed by small
pyramidal horns, one for each radiometer, 22 in total, facing small absorbing
targets, made of a commercial resin ECCOSORB CR (TM), cooled to approximately
4.5 K. Horns and targets are separated by a small gap to allow thermal
decoupling. Target and horn design is optimized for each of the LFI bands,
centered at 70, 44 and 30 GHz. Pyramidal horns are either machined inside the
radiometer 20K module or connected via external electro-formed bended
waveguides. The requirement of high stability of the reference signal imposed a
careful design for the radiometric and thermal properties of the loads.
Materials used for the manufacturing have been characterized for thermal, RF
and mechanical properties. We describe in this paper the design and the
performance of the reference system.
[7]
oai:arXiv.org:1001.4686 [pdf] - 1477095
The PLANCK LFI flight model ortho-mode transducers
D'Arcangelo, O.;
Simonetto, A.;
Figini, L.;
Pagana, E.;
Villa, F.;
Pecora, M.;
Battaglia, P.;
Bersanelli, M.;
Butler, R. C.;
Garavaglia, S.;
Guzzi, P.;
Mandolesi, N.;
Sozzi, C.
Submitted: 2010-01-26
The Low Frequency Instrument (LFI) of the ESA Planck CMB mission is an array
of 22 ultra sensitive pseudocorrelation radiometers working at 30, 44, and 70
GHz. LFI has been calibrated and delivered for integration with the satellite
to the European Space Agency on November 2006. The aim of Planck is to measure
the anisotropy and polarization of the Cosmic Background Radiation with a
sensitivity and angular resolution never reached before over the full sky. LFI
is intrinsically sensitive to polarization thanks to the use of Ortho-Mode
Transducers (OMT) located between the feedhorns and the pseudo-correlation
radiometers. The OMTs are microwave passive components that divide the incoming
radiation into two linear orthogonal components. A set of 11 OMTs (2 at 30 GHz,
3 at 44 GHz, and 6 at 70 GHz) were produced and tested. This work describes the
design, development and performance of the eleven Flight Model OMTs of LFI. The
final design was reached after several years of development. At first, Elegant
Bread Board OMTs were produced to investigate the manufacturing technology and
design requirements. Then, a set of 3 Qualification Model (QM) OMTs were
designed, manufactured and tested in order to freeze the design and the
manufacturing technology for the flight units. Finally, the Flight Models were
produced and tested. It is shown that all the OMT units have been accepted for
flight and the electromagnetic performance is at least marginally compliant
with the requirements. Mechanically, the units passed all the thermoelastic
qualification tests after a reworking necessary after the QM campaign.
[8]
oai:arXiv.org:1001.4711 [pdf] - 33175
The Planck-LFI flight model composite waveguides
D'Arcangelo, O.;
Figini, L.;
Simonetto, A.;
Villa, F.;
Pecora, M.;
Battaglia, P.;
Bersanelli, M.;
Butler, R. C.;
Cuttaia, F.;
Garavaglia, S.;
Guzzi, P.;
Mandolesi, N.;
Mennella, A.;
Morgante, G.;
Pagan, L.;
Valenziano, L.
Submitted: 2010-01-26
The Low Frequency Instrument on board the PLANCK satellite is designed to
give the most accurate map ever of the CMB anisotropy of the whole sky over a
broad frequency band spanning 27 to 77 GHz. It is made of an array of 22
pseudo-correlation radiometers, composed of 11 actively cooled (20 K) Front End
Modules (FEMs), and 11 Back End Modules (BEMs) at 300K. The connection between
the two parts is made with rectangular Wave Guides. Considerations of different
nature (thermal, electromagnetic and mechanical), imposed stringent
requirements on the WGs characteristics and drove their design. From the
thermal point of view, the WG should guarantee good insulation between the FEM
and the BEM sections to avoid overloading the cryocooler. On the other hand it
is essential that the signals do not undergo excessive attenuation through the
WG. Finally, given the different positions of the FEM modules behind the focal
surface and the mechanical constraints given by the surrounding structures,
different mechanical designs were necessary. A composite configuration of
Stainless Steel and Copper was selected to satisfy all the requirements. Given
the complex shape and the considerable length (about 1.5-2 m), manufacturing
and testing the WGs was a challenge. This work deals with the development of
the LFI WGs, including the choice of the final configuration and of the
fabrication process. It also describes the testing procedure adopted to fully
characterize these components from the electromagnetic point of view and the
space qualification process they underwent. Results obtained during the test
campaign are reported and compared with the stringent requirements. The
performance of the LFI WGs is in line with requirements, and the WGs were
successfully space qualified.
[9]
oai:arXiv.org:1001.4633 [pdf] - 33153
Planck LFI flight model feed horns
Villa, F.;
D'Arcangelo, O.;
Pecora, M.;
Figini, L.;
Nesti, R.;
Simonetto, A.;
Sozzi, C.;
Sandri, M.;
Battaglia, P.;
Guzzi, P.;
Bersanelli, M.;
Butler, R. C.;
Mandolesi, N.
Submitted: 2010-01-26
this paper is part of the Prelaunch status LFI papers published on JINST:
http://www.iop.org/EJ/journal/-page=extra.proc5/jinst The Low Frequency
Instrument is optically interfaced with the ESA Planck telescope through 11
corrugated feed horns each connected to the Radiometer Chain Assembly (RCA).
This paper describes the design, the manufacturing and the testing of the
flight model feed horns. They have been designed to optimize the LFI optical
interfaces taking into account the tight mechanical requirements imposed by the
Planck focal plane layout. All the eleven units have been successfully tested
and integrated with the Ortho Mode transducers.
[10]
oai:arXiv.org:1001.4562 [pdf] - 1024812
Planck pre-launch status: Low Frequency Instrument calibration and
expected scientific performance
Mennella, A.;
Bersanelli, M.;
Butler, R. C.;
Cuttaia, F.;
D'Arcangelo, O.;
Davis, R. J.;
Frailis, M.;
Galeotta, S.;
Gregorio, A.;
Lawrence, C. R.;
Leonardi, R.;
Lowe, S. R.;
Mandolesi, N.;
Maris, M.;
Meinhold, P.;
Mendes, L.;
Morgante, G.;
Sandri, M.;
Stringhetti, L.;
Terenzi, L.;
Tomasi, M.;
Valenziano, L.;
Villa, F.;
Zacchei, A.;
Zonca, A.;
Balasini, M.;
Franceschet, C.;
Battaglia, P.;
Lapolla, P. M.;
Leutenegger, P.;
Miccolis, M.;
Pagan, L.;
Silvestri, R.;
Aja, B.;
Artal, E.;
Baldan, G.;
Bastia, P.;
Bernardino, T.;
Boschini, L.;
Cafagna, G.;
Cappellini, B.;
Cavaliere, F.;
Colombo, F.;
de La Fuente, L.;
Edgeley, J.;
Falvella, M. C.;
Ferrari, F.;
Fogliani, S.;
Franceschi, E.;
Gaier, T.;
Gomez, F.;
Herreros, J. M.;
Hildebrandt, S.;
Hoyland, R.;
Hughes, N.;
Jukkala, P.;
Kettle, D.;
Laaninen, M.;
Lawson, D.;
Leahy, P.;
Levin, S.;
Lilje, P. B.;
Maino, D.;
Malaspina, M.;
Manzato, P.;
Marti-Canales, J.;
Martinez-Gonzalez, E.;
Mediavilla, A.;
Pasian, F.;
Pascual, J. P.;
Pecora, M.;
Peres-Cuevas, L.;
Platania, P.;
Pospieszalsky, M.;
Poutanen, T.;
Rebolo, R.;
Roddis, N.;
Salmon, M.;
Seiffert, M.;
Simonetto, A.;
Sozzi, C.;
Tauber, J.;
Tuovinen, J.;
Varis, J.;
Wilkinson, A.;
Winder, F.
Submitted: 2010-01-25
We give the calibration and scientific performance parameters of the Planck
Low Frequency Instrument (LFI) measured during the ground cryogenic test
campaign. These parameters characterise the instrument response and constitute
our best pre-launch knowledge of the LFI scientific performance. The LFI shows
excellent $1/f$ stability and rejection of instrumental systematic effects;
measured noise performance shows that LFI is the most sensitive instrument of
its kind. The set of measured calibration parameters will be updated during
flight operations through the end of the mission.
[11]
oai:arXiv.org:1001.3321 [pdf] - 1024699
Planck pre-launch status: Design and description of the Low Frequency
Instrument
Bersanelli, M.;
Mandolesi, N.;
Butler, R. C.;
Mennella, A.;
Villa, F.;
Aja, B.;
Artal, E.;
Artina, E.;
Baccigalupi, C.;
Balasini, M.;
Baldan, G.;
Banday, A.;
Bastia, P.;
Battaglia, P.;
Bernardino, T.;
Blackhurst, E.;
Boschini, L.;
Burigana, C.;
Cafagna, G.;
Cappellini, B.;
Cavaliere, F.;
Colombo, F.;
Crone, G.;
Cuttaia, F.;
D'Arcangelo, O.;
Danese, L.;
Davies, R. D.;
Davis, R. J.;
De Angelis, L.;
De Gasperis, G. C.;
De La Fuente, L.;
De Rosa, A.;
De Zotti, G.;
Falvella, M. C.;
Ferrari, F.;
Ferretti, R.;
Figini, L.;
Fogliani, S.;
Franceschet, C.;
Franceschi, E.;
Gaier, T.;
Garavaglia, S.;
Gomez, F.;
Gorski, K.;
Gregorio, A.;
Guzzi, P.;
Herreros, J. M.;
Hildebrandt, S. R.;
Hoyland, R.;
Hughes, N.;
Janssen, M.;
Jukkala, P.;
Kettle, D.;
Kilpia, V. H.;
Laaninen, M.;
Lapolla, P. M.;
Lawrence, C. R.;
Leahy, J. P.;
Leonardi, R.;
Leutenegger, P.;
Levin, S.;
Lilje, P. B.;
Lowe, S. R.;
Lubin, D. Lawson P. M.;
Maino, D.;
Malaspina, M.;
Maris, M.;
Marti-Canales, J.;
Martinez-Gonzalez, E.;
Mediavilla, A.;
Meinhold, P.;
Miccolis, M.;
Morgante, G.;
Natoli, P.;
Nesti, R.;
Pagan, L.;
Paine, C.;
Partridge, B.;
Pascual, J. P.;
Pasian, F.;
Pearson, D.;
Pecora, M.;
Perrotta, F.;
Platania, P.;
Pospieszalski, M.;
Poutanen, T.;
Prina, M.;
Rebolo, R.;
Roddis, N.;
Rubino-Martin, J. A.;
Salmon, n M. J.;
Sandri, M.;
Seiffert, M.;
Silvestri, R.;
Simonetto, A.;
Sjoman, P.;
Smoot, G. F.;
Sozzi, C.;
Stringhetti, L.;
Taddei, E.;
Tauber, J.;
Terenzi, L.;
Tomasi, M.;
Tuovinen, J.;
Valenziano, L.;
Varis, J.;
Vittorio, N.;
Wade, L. A.;
Wilkinson, A.;
Winder, F.;
Zacchei, A.;
Zonca, A.
Submitted: 2010-01-19
In this paper we present the Low Frequency Instrument (LFI), designed and
developed as part of the Planck space mission, the ESA program dedicated to
precision imaging of the cosmic microwave background (CMB). Planck-LFI will
observe the full sky in intensity and polarisation in three frequency bands
centred at 30, 44 and 70 GHz, while higher frequencies (100-850 GHz) will be
covered by the HFI instrument. The LFI is an array of microwave radiometers
based on state-of-the-art Indium Phosphide cryogenic HEMT amplifiers
implemented in a differential system using blackbody loads as reference
signals. The front-end is cooled to 20K for optimal sensitivity and the
reference loads are cooled to 4K to minimise low frequency noise. We provide an
overview of the LFI, discuss the leading scientific requirements and describe
the design solutions adopted for the various hardware subsystems. The main
drivers of the radiometric, optical and thermal design are discussed, including
the stringent requirements on sensitivity, stability, and rejection of
systematic effects. Further details on the key instrument units and the results
of ground calibration are provided in a set of companion papers.
[12]
oai:arXiv.org:1001.2657 [pdf] - 1024642
Planck pre-launch status: the Planck-LFI programme
Mandolesi, N.;
Bersanelli, M.;
Butler, R. C.;
Artal, E.;
Baccigalupi, C.;
Balbi, A.;
Banday, A. J.;
Barreiro, R. B.;
Bartelmann, M.;
Bennett, K.;
Bhandari, P.;
Bonaldi, A.;
Borrill, J.;
Bremer, M.;
Burigana, C.;
Bowman, R. C.;
Cabella, P.;
Cantalupo, C.;
Cappellini, B.;
Courvoisier, T.;
Crone, G.;
Cuttaia, F.;
Danese, L.;
D'Arcangelo, O.;
Davies, R. D.;
Davis, R. J.;
De Angelis, L.;
de Gasperis, G.;
De Rosa, A.;
De Troia, G.;
de Zotti, G.;
Dick, J.;
Dickinson, C.;
Diego, J. M.;
Donzelli, S.;
Dörl, U.;
Dupac, X.;
Enßlin, T. A.;
Eriksen, H. K.;
Falvella, M. C.;
Finelli, F.;
Frailis, M.;
Franceschi, E.;
Gaier, T.;
Galeotta, S.;
Gasparo, F.;
Giardino, G.;
Gomez, F.;
Gonzalez-Nuevo, J.;
Górski, K. M.;
Gregorio, A.;
Gruppuso, A.;
Hansen, F.;
Hell, R.;
Herranz, D.;
Herreros, J. M.;
Hildebrandt, S.;
Hovest, W.;
Hoyland, R.;
Huffenberger, K.;
Janssen, M.;
Jaffe, T.;
Keihänen, E.;
Keskitalo, R.;
Kisner, T.;
Kurki-Suonio, H.;
Lähteenmäki, A.;
Lawrence, C. R.;
Leach, S. M.;
Leahy, J. P.;
Leonardi, R.;
Levin, S.;
Lilje, P. B.;
López-Caniego, M.;
Lowe, S. R.;
Lubin, P. M.;
Maino, D.;
Malaspina, M.;
Maris, M.;
Marti-Canales, J.;
Martinez-Gonzalez, E.;
Massardi, M.;
Matarrese, S.;
Matthai, F.;
Meinhold, P.;
Melchiorri, A.;
Mendes, L.;
Mennella, A.;
Morgante, G.;
Morigi, G.;
Morisset, N.;
Moss, A.;
Nash, A.;
Natoli, P.;
Nesti, R.;
Paine, C.;
Partridge, B.;
Pasian, F.;
Passvogel, T.;
Pearson, D.;
Pérez-Cuevas, L.;
Perrotta, F.;
Polenta, G.;
Popa, L. A.;
Poutanen, T.;
Prezeau, G.;
Prina, M.;
Rachen, J. P.;
Rebolo, R.;
Reinecke, M.;
Ricciardi, S.;
Riller, T.;
Rocha, G.;
Roddis, N.;
Rohlfs, R.;
Rubiño-Martin, J. A.;
Salerno, E.;
Sandri, M.;
Scott, D.;
Seiffert, M.;
Silk, J.;
Simonetto, A.;
Smoot, G. F.;
Sozzi, C.;
Sternberg, J.;
Stivoli, F.;
Stringhetti, L.;
Tauber, J.;
Terenzi, L.;
Tomasi, M.;
Tuovinen, J.;
Türler, M.;
Valenziano, L.;
Varis, J.;
Vielva, P.;
Villa, F.;
Vittorio, N.;
Wade, L.;
White, M.;
White, S.;
Wilkinson, A.;
Zacchei, A.;
Zonca, A.
Submitted: 2010-01-15
This paper provides an overview of the Low Frequency Instrument (LFI)
programme within the ESA Planck mission. The LFI instrument has been developed
to produce high precision maps of the microwave sky at frequencies in the range
27-77 GHz, below the peak of the cosmic microwave background (CMB) radiation
spectrum. The scientific goals are described, ranging from fundamental
cosmology to Galactic and extragalactic astrophysics. The instrument design and
development are outlined, together with the model philosophy and testing
strategy. The instrument is presented in the context of the Planck mission. The
LFI approach to ground and inflight calibration is described. We also describe
the LFI ground segment. We present the results of a number of tests
demonstrating the capability of the LFI data processing centre (DPC) to
properly reduce and analyse LFI flight data, from telemetry information to
calibrated and cleaned time ordered data, sky maps at each frequency (in
temperature and polarization), component emission maps (CMB and diffuse
foregrounds), catalogs for various classes of sources (the Early Release
Compact Source Catalogue and the Final Compact Source Catalogue). The
organization of the LFI consortium is briefly presented as well as the role of
the core team in data analysis and scientific exploitation. All tests carried
out on the LFI flight model demonstrate the excellent performance of the
instrument and its various subunits. The data analysis pipeline has been tested
and its main steps verified. In the first three months after launch, the
commissioning, calibration, performance, and verification phases will be
completed, after which Planck will begin its operational life, in which LFI
will have an integral part.
[13]
oai:arXiv.org:astro-ph/0310058 [pdf] - 59721
The Low Frequency Instrument in the ESA Planck mission
Mennella, A.;
Bersanelli, M.;
Cappellini, B.;
Maino, D.;
Platania, P.;
Garavaglia, S.;
Butler, R. C.;
Pasian, N. Mandolesi F.;
D'arcangelo, O.;
Simonetto, A.;
Sozzi, C.
Submitted: 2003-10-02
Measurements of the cosmic microwave background (CMB) allow high precision
observation of the cosmic plasma at redshift z~1100. After the success of the
NASA satellite COBE, that in 1992 provided the first detection of the CMB
anisotropy, results from many ground-based and balloon-borne experiments have
showed a remarkable consistency between different results and provided
quantitative estimates of fundamental cosmological properties. During the
current year the team of the NASA WMAP satellite has released the first
improved full-sky maps of the CMB since COBE, leading to a deeper insight in
the origin and evolution of the Universe. The ESA satellite Planck, scheduled
for launch in 2007, is designed to provide the ultimate measurement of the CMB
temperature anisotropy over the full sky, with an accuracy that will be limited
only by astrophysical foregrounds, and robust detection of polarisation
anisotropy. Planck will observe the sky with two instruments over a wide
spectral band (the Low Frequency Instrument, based on coherent radiometers,
from 30 to 70 GHz and the High Frequency Instrument, based on bolometric
detectors, from 100 to 857 GHz). The mission performances will improve
dramatically the scientific return compared to WMAP. Furthermore the LFI
radiometers (as well as some of the HFI bolometers) are intrinsically sensitive
to polarisation so that by combining the data from different receivers it will
be possible to measure accurately the E mode and to detect the B mode of the
polarisation power spectrum. Planck sensitivity will offer also the possibility
to detect the non-Gaussianities imprinted in the CMB.
[14]
oai:arXiv.org:astro-ph/0307309 [pdf] - 58022
High Performances Corrugated Feed Horns for Space Applications at
Millimetre Wavelengths
Villa, F.;
Sandri, M.;
Mandolesi, N.;
Nesti, R.;
Bersanelli, M.;
Simonetto, A.;
Sozzi, C.;
D'Arcangelo, O.;
Muzzini, V.;
Mennella, A.;
Guzzi, P.;
Radaelli, P.;
Fusi, R.;
Alippi, E.
Submitted: 2003-07-16
We report on the design, fabrication and testing of a set of high performance
corrugated feed horns at 30 GHz, 70 GHz and 100 GHz, built as advanced
prototypes for the Low Frequency Instrument (LFI) of the ESA Planck mission.
The electromagnetic designs include linear (100 GHz) and dual shaped (30 and 70
GHz) profiles. Fabrication has been achieved by direct machining at 30 GHz, and
by electro-formation at higher frequencies. The measured performances on side
lobes and return loss meet the stringent Planck requirements over the large
(20%) instrument bandwidth. Moreover, the advantage in terms of main lobe shape
and side lobes levels of the dual profiled designs has been demonstrated.