sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Silvestri, R.

Normalized to: Silvestri, R.

9 article(s) in total. 214 co-authors, from 1 to 9 common article(s). Median position in authors list is 33,0.

[1]  oai:arXiv.org:1101.2038  [pdf] - 955981
Planck early results. III. First assessment of the Low Frequency Instrument in-flight performance
Mennella, A.; Bersanelli, M.; Butler, R. C.; Curto, A.; Cuttaia, F.; Davis, R. J.; Dick, J.; Frailis, M.; Galeotta, S.; Gregorio, A.; Kurki-Suonio, H.; Lawrence, C. R.; Leach, S.; Leahy, J. P.; Lowe, S.; Maino, D.; Mandolesi, N.; Maris, M.; Martínez-González, E.; Meinhold, P. R.; Morgante, G.; Pearson, D.; Perrotta, F.; Polenta, G.; Poutanen, T.; Sandri, M.; Seiffert, M. D.; Suur-Uski, A. -S.; Tavagnacco, D.; Terenzi, L.; Tomasi, M.; Valiviita, J.; Villa, F.; Watson, R.; Wilkinson, A.; Zacchei, A.; Zonca, A.; Aja, B.; Artal, E.; Baccigalupi, C.; Banday, A. J.; Barreiro, R. B.; Bartlett, J. G.; Bartolo, N.; Battaglia, P.; Bennett, K.; Bonaldi, A.; Bonavera, L.; Borrill, J.; Bouchet, F. R.; Burigana, C.; Cabella, P.; Cappellini, B.; Chen, X.; Colombo, L.; Cruz, M.; Danese, L.; D'Arcangelo, O.; Davies, R. D.; de Gasperis, G.; de Rosa, A.; de Zotti, G.; Dickinson, C.; Diego, J. M.; Donzelli, S.; Efstathiou, G.; Enßlin, T. A.; Eriksen, H. K.; Falvella, M. C.; Finelli, F.; Foley, S.; Franceschet, C.; Franceschi, E.; Gaier, T. C.; Génova-Santos, R. T.; George, D.; Gómez, F.; González-Nuevo, J.; Górski, K. M.; Gruppuso, A.; Hansen, F. K.; Herranz, D.; Herreros, J. M.; Hoyland, R. J.; Hughes, N.; Jewell, J.; Jukkala, P.; Juvela, M.; Kangaslahti, P.; Keihänen, E.; Keskitalo, R.; Kilpia, V. -H.; Kisner, T. S.; Knoche, J.; Knox, L.; Laaninen, M.; Lähteenmäki, A.; Lamarre, J. -M.; Leonardi, R.; León-Tavares, J.; Leutenegger, P.; Lilje, P. B.; López-Caniego, M.; Lubin, P. M.; Malaspina, M.; Marinucci, D.; Massardi, M.; Matarrese, S.; Matthai, F.; Melchiorri, A.; Mendes, L.; Miccolis, M.; Migliaccio, M.; Mitra, S.; Moss, A.; Natoli, P.; Nesti, R.; Nørgaard-Nielsen, H. U.; Pagano, L.; Paladini, R.; Paoletti, D.; Partridge, B.; Pasian, F.; Pettorino, V.; Pietrobon, D.; Pospieszalski, M.; Prézeau, G.; Prina, M.; Procopio, P.; Puget, J. -L.; Quercellini, C.; Rachen, J. P.; Rebolo, R.; Reinecke, M.; Ricciardi, S.; Robbers, G.; Rocha, G.; Roddis, N.; Rubiño-Martín, J. A.; Savelainen, M.; Scott, D.; Silvestri, R.; Simonetto, A.; Sjoman, P.; Smoot, G. F.; Sozzi, C.; Stringhetti, L.; Tauber, J. A.; Tofani, G.; Toffolatti, L.; Tuovinen, J.; Türler, M.; Umana, G.; Valenziano, L.; Varis, J.; Vielva, P.; Vittorio, N.; Wade, L. A.; Watson, C.; White, S. D. M.; Winder, F.
Comments: Published version
Submitted: 2011-01-11, last modified: 2011-12-19
The scientific performance of the Planck Low Frequency Instrument (LFI) after one year of in-orbit operation is presented. We describe the main optical parameters and discuss photometric calibration, white noise sensitivity, and noise properties. A preliminary evaluation of the impact of the main systematic effects is presented. For each of the performance parameters, we outline the methods used to obtain them from the flight data and provide a comparison with pre-launch ground assessments, which are essentially confirmed in flight.
[2]  oai:arXiv.org:1005.2541  [pdf] - 1032478
Planck pre-launch status: calibration of the Low Frequency Instrument flight model radiometers
Comments: 15 pages, 18 figures. Accepted for publication in Astronomy and Astrophysics
Submitted: 2010-05-14
The Low Frequency Instrument (LFI) on-board the ESA Planck satellite carries eleven radiometer subsystems, called Radiometer Chain Assemblies (RCAs), each composed of a pair of pseudo-correlation receivers. We describe the on-ground calibration campaign performed to qualify the flight model RCAs and to measure their pre-launch performances. Each RCA was calibrated in a dedicated flight-like cryogenic environment with the radiometer front-end cooled to 20K and the back-end at 300K, and with an external input load cooled to 4K. A matched load simulating a blackbody at different temperatures was placed in front of the sky horn to derive basic radiometer properties such as noise temperature, gain, and noise performance, e.g. 1/f noise. The spectral response of each detector was measured as was their susceptibility to thermal variation. All eleven LFI RCAs were calibrated. Instrumental parameters measured in these tests, such as noise temperature, bandwidth, radiometer isolation, and linearity, provide essential inputs to the Planck-LFI data analysis.
[3]  oai:arXiv.org:1001.4644  [pdf] - 33160
Cryogenic environment and performance for testing the Planck radiometers
Comments: This is an author-created, un-copyedited version of an article accepted for publication in JINST. IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from it. The definitive publisher authenticated version is available online at 10.1088/1748-0221/4/12/T12015
Submitted: 2010-01-26
This paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jinst The Planck LFI Radiometer Chain Assemblies (RCAs) have been calibrated in two dedicated cryogenic facilities. In this paper the facilities and the related instrumentation are described. The main satellite thermal interfaces for the single chains have to be reproduced and stability requirements have to be satisfied. Setup design, problems occurred and improving solutions implemented are discussed. Performance of the cryogenic setup are reported.
[4]  oai:arXiv.org:1001.4648  [pdf] - 33162
Planck-LFI radiometers tuning
Comments: This is an author-created, un-copyedited version of an article accepted for publication in JINST. IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from it. The definitive publisher authenticated version is available online at http://dx.doi.org/10.1088/1748-0221/4/12/T12013]
Submitted: 2010-01-26
"This paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jinst" This paper describes the Planck Low Frequency Instrument tuning activities performed through the ground test campaigns, from Unit to Satellite Levels. Tuning is key to achieve the best possible instrument performance and tuning parameters strongly depend on thermal and electrical conditions. For this reason tuning has been repeated several times during ground tests and it has been repeated in flight before starting nominal operations. The paper discusses the tuning philosophy, the activities and the obtained results, highlighting developments and changes occurred during test campaigns. The paper concludes with an overview of tuning performed during the satellite cryogenic test campaign (Summer 2008) and of the plans for the just started in-flight calibration.
[5]  oai:arXiv.org:1001.4589  [pdf] - 33143
Planck-LFI radiometers' spectral response
Comments: 16 pages, 9 figures, this paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jinst
Submitted: 2010-01-26
The Low Frequency Instrument (LFI) is an array of pseudo-correlation radiometers on board the Planck satellite, the ESA mission dedicated to precision measurements of the Cosmic Microwave Background. The LFI covers three bands centred at 30, 44 and 70 GHz, with a goal bandwidth of 20% of the central frequency. The characterization of the broadband frequency response of each radiometer is necessary to understand and correct for systematic effects, particularly those related to foreground residuals and polarization measurements. In this paper we present the measured band shape of all the LFI channels and discuss the methods adopted for their estimation. The spectral characterization of each radiometer was obtained by combining the measured spectral response of individual units through a dedicated RF model of the LFI receiver scheme. As a consistency check, we also attempted end-to-end spectral measurements of the integrated radiometer chain in a cryogenic chamber. However, due to systematic effects in the measurement setup, only qualitative results were obtained from these tests. The measured LFI bandpasses exhibit a moderate level of ripple, compatible with the instrument scientific requirements.
[6]  oai:arXiv.org:1001.4653  [pdf] - 33163
Thermal susceptibility of the Planck-LFI receivers
Comments: This is an author-created, un-copyedited version of an article accepted for publication in Journal of Instrumentation. IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from it. The definitive publisher authenticated version is available online at 10.1088/1748-0221/4/12/T12012
Submitted: 2010-01-26
This paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jinst . This paper describes the impact of the Planck Low Frequency Instrument front end physical temperature fluctuations on the output signal. The origin of thermal instabilities in the instrument are discussed, and an analytical model of their propagation and impact on the receivers signal is described. The experimental test setup dedicated to evaluate these effects during the instrument ground calibration is reported together with data analysis methods. Finally, main results obtained are discussed and compared to the requirements.
[7]  oai:arXiv.org:1001.4610  [pdf] - 33148
The linearity response of the Planck-LFI flight model receivers
Comments: this paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jinst; This is an author-created, un-copyedited version of an article accepted for publication in JINST. IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from it. The definitive publisher authenticated version is available online at 10.1088/1748-0221/4/12/T12011.
Submitted: 2010-01-26
In this paper we discuss the linearity response of the Planck-LFI receivers, with particular reference to signal compression measured on the 30 and 44 GHz channels. In the article we discuss the various sources of compression and present a model that accurately describes data measured during tests performed with individual radiomeric chains. After discussing test results we present the best parameter set representing the receiver response and discuss the impact of non linearity on in-flight calibration, which is shown to be negligible.
[8]  oai:arXiv.org:1001.4562  [pdf] - 1024812
Planck pre-launch status: Low Frequency Instrument calibration and expected scientific performance
Comments: Accepted for publications in Astronomy and Astrophysics. Astronomy & Astrophysics, 2010 (acceptance date: 12 Jan 2010)
Submitted: 2010-01-25
We give the calibration and scientific performance parameters of the Planck Low Frequency Instrument (LFI) measured during the ground cryogenic test campaign. These parameters characterise the instrument response and constitute our best pre-launch knowledge of the LFI scientific performance. The LFI shows excellent $1/f$ stability and rejection of instrumental systematic effects; measured noise performance shows that LFI is the most sensitive instrument of its kind. The set of measured calibration parameters will be updated during flight operations through the end of the mission.
[9]  oai:arXiv.org:1001.3321  [pdf] - 1024699
Planck pre-launch status: Design and description of the Low Frequency Instrument
Bersanelli, M.; Mandolesi, N.; Butler, R. C.; Mennella, A.; Villa, F.; Aja, B.; Artal, E.; Artina, E.; Baccigalupi, C.; Balasini, M.; Baldan, G.; Banday, A.; Bastia, P.; Battaglia, P.; Bernardino, T.; Blackhurst, E.; Boschini, L.; Burigana, C.; Cafagna, G.; Cappellini, B.; Cavaliere, F.; Colombo, F.; Crone, G.; Cuttaia, F.; D'Arcangelo, O.; Danese, L.; Davies, R. D.; Davis, R. J.; De Angelis, L.; De Gasperis, G. C.; De La Fuente, L.; De Rosa, A.; De Zotti, G.; Falvella, M. C.; Ferrari, F.; Ferretti, R.; Figini, L.; Fogliani, S.; Franceschet, C.; Franceschi, E.; Gaier, T.; Garavaglia, S.; Gomez, F.; Gorski, K.; Gregorio, A.; Guzzi, P.; Herreros, J. M.; Hildebrandt, S. R.; Hoyland, R.; Hughes, N.; Janssen, M.; Jukkala, P.; Kettle, D.; Kilpia, V. H.; Laaninen, M.; Lapolla, P. M.; Lawrence, C. R.; Leahy, J. P.; Leonardi, R.; Leutenegger, P.; Levin, S.; Lilje, P. B.; Lowe, S. R.; Lubin, D. Lawson P. M.; Maino, D.; Malaspina, M.; Maris, M.; Marti-Canales, J.; Martinez-Gonzalez, E.; Mediavilla, A.; Meinhold, P.; Miccolis, M.; Morgante, G.; Natoli, P.; Nesti, R.; Pagan, L.; Paine, C.; Partridge, B.; Pascual, J. P.; Pasian, F.; Pearson, D.; Pecora, M.; Perrotta, F.; Platania, P.; Pospieszalski, M.; Poutanen, T.; Prina, M.; Rebolo, R.; Roddis, N.; Rubino-Martin, J. A.; Salmon, n M. J.; Sandri, M.; Seiffert, M.; Silvestri, R.; Simonetto, A.; Sjoman, P.; Smoot, G. F.; Sozzi, C.; Stringhetti, L.; Taddei, E.; Tauber, J.; Terenzi, L.; Tomasi, M.; Tuovinen, J.; Valenziano, L.; Varis, J.; Vittorio, N.; Wade, L. A.; Wilkinson, A.; Winder, F.; Zacchei, A.; Zonca, A.
Comments: 23 pages, 31 figures, accepted by Astronomy and Astrophysics, Planck LFI technical papers published by JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/1748-0221
Submitted: 2010-01-19
In this paper we present the Low Frequency Instrument (LFI), designed and developed as part of the Planck space mission, the ESA program dedicated to precision imaging of the cosmic microwave background (CMB). Planck-LFI will observe the full sky in intensity and polarisation in three frequency bands centred at 30, 44 and 70 GHz, while higher frequencies (100-850 GHz) will be covered by the HFI instrument. The LFI is an array of microwave radiometers based on state-of-the-art Indium Phosphide cryogenic HEMT amplifiers implemented in a differential system using blackbody loads as reference signals. The front-end is cooled to 20K for optimal sensitivity and the reference loads are cooled to 4K to minimise low frequency noise. We provide an overview of the LFI, discuss the leading scientific requirements and describe the design solutions adopted for the various hardware subsystems. The main drivers of the radiometric, optical and thermal design are discussed, including the stringent requirements on sensitivity, stability, and rejection of systematic effects. Further details on the key instrument units and the results of ground calibration are provided in a set of companion papers.