Normalized to: Shortt, B.
[1]
oai:arXiv.org:1701.05548 [pdf] - 1534765
Localisation of gamma-ray interaction points in thick monolithic CeBr3
and LaBr3:Ce scintillators
Submitted: 2017-01-19
Localisation of gamma-ray interaction points in monolithic scintillator
crystals can simplify the design and improve the performance of a future
Compton telescope for gamma-ray astronomy. In this paper we compare the
position resolution of three monolithic scintillators: a 28x28x20 mm3 (length x
breadth x thickness) LaBr3:Ce crystal, a 25x25x20 mm3 CeBr3 crystal and a
25x25x10 mm3 CeBr3 crystal. Each crystal was encapsulated and coupled to an
array of 4x4 silicon photomultipliers through an optical window. The
measurements were conducted using 81 keV and 356 keV gamma-rays from a
collimated 133Ba source. The 3D position reconstruction of interaction points
was performed using artificial neural networks trained with experimental data.
Although the position resolution was significantly better for the thinner
crystal, the 20 mm thick CeBr3 crystal showed an acceptable resolution of about
5.4 mm FWHM for the x and y coordinates, and 7.8 mm FWHM for the z-coordinate
(crystal depth) at 356 keV. These values were obtained from the full position
scans of the crystal sides. The position resolution of the LaBr3:Ce crystal was
found to be considerably worse, presumably due to the highly diffusive optical
in- terface between the crystal and the optical window of the enclosure. The
energy resolution (FWHM) measured for 662 keV gamma-rays was 4.0% for LaBr3:Ce
and 5.5% for CeBr3. The same crystals equipped with a PMT (Hamamatsu R6322-100)
gave an energy resolution of 3.0% and 4.7%, respectively.
[2]
oai:arXiv.org:1409.8516 [pdf] - 873983
Development of large radii half-wave plates for CMB satellite missions
Pisano, G.;
Maffei, B.;
Ng, M. W.;
Haynes, V.;
Brown, M.;
Noviello, F.;
de Bernardis, P.;
Masi, S.;
Piacentini, F.;
Pagano, L.;
Salatino, M.;
Ellison, B.;
Henry, M.;
de Maagt, P.;
Shortt, B.
Submitted: 2014-09-30
The successful European Space Agency (ESA) Planck mission has mapped the
Cosmic Microwave Background (CMB) temperature anisotropy with unprecedented
accuracy. However, Planck was not designed to detect the polarised components
of the CMB with comparable precision. The BICEP2 collaboration has recently
reported the first detection of the B-mode polarisation. ESA is funding the
development of critical enabling technologies associated with B-mode
polarisation detection, one of these being large diameter half-wave plates. We
compare different polarisation modulators and discuss their respective
trade-offs in terms of manufacturing, RF performance and thermo-mechanical
properties. We then select the most appropriate solution for future satellite
missions, optimized for the detection of B-modes.