Normalized to: Shiu, C.
[1]
oai:arXiv.org:1711.04169 [pdf] - 1755845
280 GHz Focal Plane Unit Design and Characterization for the SPIDER-2
Suborbital Polarimeter
Bergman, A. S.;
Ade, P. A. R.;
Akers, S.;
Amiri, M.;
Austermann, J. A.;
Beall, J. A.;
Becker, D. T.;
Benton, S. J.;
Bock, J. J.;
Bond, J. R.;
Bryan, S. A.;
Chiang, H. C.;
Contaldi, C. R.;
Domagalski, R. S;
Doré, O.;
Duff, S. M.;
Duivenvoorden, A. J.;
Eriksen, H. K.;
Farhang, M.;
Filippini, J. P.;
Fissel, L. M.;
Fraisse, A. A.;
Freese, K.;
Galloway, M.;
Gambrel, A. E.;
Gandilo, N. N.;
Ganga, K.;
Grigorian, A.;
Gualtieri, R.;
Gudmundsson, J. E.;
Halpern, M.;
Hartley, J.;
Hasselfield, M.;
Hilton, G.;
Holmes, W.;
Hristov, V. V.;
Huang, Z.;
Hubmayr, J.;
Irwin, K. D.;
Jones, W. C.;
Khan, A.;
Kuo, C. L.;
Kermish, Z. D.;
Li, S.;
Mason, P. V.;
Megerian, K.;
Moncelsi, L.;
Morford, T. A.;
Nagy, J. M.;
Netterfield, C. B.;
Nolta, M.;
Osherson, B.;
Padilla, I. L.;
Racine, B.;
Rahlin, A. S.;
Redmond, S.;
Reintsema, C.;
Romualdez, L. J.;
Ruhl, J. E.;
Runyan, M. C.;
Ruud, T. M.;
Shariff, J. A.;
Shaw, E. C.;
Shiu, C.;
Soler, J. D.;
Song, X.;
Trangsrud, A.;
Tucker, C.;
Tucker, R. S.;
Turner, A. D.;
Ullom, J.;
van der List, J. F.;
Van Lanen, J.;
Vissers, M. R.;
Weber, A. C.;
Wehus, I. K.;
Wen, S.;
Wiebe, D. V.;
Young, E. Y.
Submitted: 2017-11-11, last modified: 2017-11-22
We describe the construction and characterization of the 280 GHz bolometric
focal plane units (FPUs) to be deployed on the second flight of the
balloon-borne SPIDER instrument. These FPUs are vital to SPIDER's primary
science goal of detecting or placing an upper limit on the amplitude of the
primordial gravitational wave signature in the cosmic microwave background
(CMB) by constraining the B-mode contamination in the CMB from Galactic dust
emission. Each 280 GHz focal plane contains a 16 x 16 grid of corrugated
silicon feedhorns coupled to an array of aluminum-manganese transition-edge
sensor (TES) bolometers fabricated on 150 mm diameter substrates. In total, the
three 280 GHz FPUs contain 1,530 polarization sensitive bolometers (765 spatial
pixels) optimized for the low loading environment in flight and read out by
time-division SQUID multiplexing. In this paper we describe the mechanical,
thermal, and magnetic shielding architecture of the focal planes and present
cryogenic measurements which characterize yield and the uniformity of several
bolometer parameters. The assembled FPUs have high yields, with one array as
high as 95% including defects from wiring and readout. We demonstrate high
uniformity in device parameters, finding the median saturation power for each
TES array to be ~3 pW at 300 mK with a less than 6% variation across each array
at one standard deviation. These focal planes will be deployed alongside the 95
and 150 GHz telescopes in the SPIDER-2 instrument, slated to fly from McMurdo
Station in Antarctica in December 2018.
[2]
oai:arXiv.org:1511.04488 [pdf] - 1347622
Low Noise Titanium Nitride KIDs for SuperSpec: A Millimeter-Wave On-Chip
Spectrometer
Hailey-Dunsheath, S.;
Shirokoff, E.;
Barry, P. S.;
Bradford, C. M.;
Chapman, S.;
Che, G.;
Glenn, J.;
Hollister, M.;
Kovács, A.;
LeDuc, H. G.;
Mauskopf, P.;
McKenney, C.;
O'Brient, R.;
Padin, S.;
Reck, T.;
Shiu, C.;
Tucker, C. E.;
Wheeler, J.;
Williamson, R.;
Zmuidzinas, J.
Submitted: 2015-11-13
SuperSpec is a novel on-chip spectrometer we are developing for multi-object,
moderate resolution (R = 100 - 500), large bandwidth (~1.65:1) submillimeter
and millimeter survey spectroscopy of high-redshift galaxies. The spectrometer
employs a filter bank architecture, and consists of a series of half-wave
resonators formed by lithographically-patterned superconducting transmission
lines. The signal power admitted by each resonator is detected by a lumped
element titanium nitride (TiN) kinetic inductance detector (KID) operating at
100 - 200 MHz. We have tested a new prototype device that achieves the targeted
R = 100 resolving power, and has better detector sensitivity and optical
efficiency than previous devices. We employ a new method for measuring photon
noise using both coherent and thermal sources of radiation to cleanly separate
the contributions of shot and wave noise. We report an upper limit to the
detector NEP of $1.4\times10^{-17}$ W Hz$^{-1/2}$, within 10% of the photon
noise limited NEP for a ground-based R=100 spectrometer.