Normalized to: Shirley, I.
[1]
oai:arXiv.org:1902.09640 [pdf] - 1838469
Design and Bolometer Characterization of the SPT-3G First-year Focal
Plane
Everett, W.;
Ade, P. A. R.;
Ahmed, Z.;
Anderson, A. J.;
Austermann, J. E.;
Avva, J. S.;
Thakur, R. Basu;
Bender, A. N.;
Benson, B. A.;
Carlstrom, J. E.;
Carter, F. W.;
Cecil, T.;
Chang, C. L.;
Cliche, J. F.;
Cukierman, A.;
Denison, E. V.;
de Haan, T.;
Ding, J.;
Dobbs, M. A.;
Dutcher, D.;
Foster, A.;
Gannon, R. N.;
Gilbert, A.;
Groh, J. C.;
Halverson, N. W.;
Harke-Hosemann, A. H.;
Harrington, N. L.;
Henning, J. W.;
Hilton, G. C.;
Holzapfel, W. L.;
Huang, N.;
Irwin, K. D.;
Jeong, O. B.;
Jonas, M.;
Khaire, T.;
Kofman, A. M.;
Korman, M.;
Kubik, D.;
Kuhlmann, S.;
Kuo, C. L.;
Lee, A. T.;
Lowitz, A. E.;
Meyer, S. S.;
Michalik, D.;
Montgomery, J.;
Nadolski, A.;
Natoli, T.;
Nguyen, H.;
Noble, G. I.;
Novosad, V.;
Padin, S.;
Pan, Z.;
Pearson, J.;
Posada, C. M.;
Rahlin, A.;
Ruhl, J. E.;
Saunders, L. J.;
Sayre, J. T.;
Shirley, I.;
Shirokoff, E.;
Smecher, G.;
Sobrin, J. A.;
Stark, A. A.;
Story, K. T.;
Suzuki, A.;
Tang, Q. Y.;
Thompson, K. L.;
Tucker, C.;
Vale, L. R.;
Vanderlinde, K.;
Vieira, J. D.;
Wang, G.;
Whitehorn, N.;
Yefremenko, V.;
Yoon, K. W.;
Young, M. R.
Submitted: 2019-02-25
During the austral summer of 2016-17, the third-generation camera, SPT-3G,
was installed on the South Pole Telescope, increasing the detector count in the
focal plane by an order of magnitude relative to the previous generation.
Designed to map the polarization of the cosmic microwave background, SPT-3G
contains ten 6-in-hexagonal modules of detectors, each with 269 trichroic and
dual-polarization pixels, read out using 68x frequency-domain multiplexing.
Here we discuss design, assembly, and layout of the modules, as well as early
performance characterization of the first-year array, including yield and
detector properties.
[2]
oai:arXiv.org:1805.03219 [pdf] - 1679898
Optical Characterization of the SPT-3G Focal Plane
Pan, Zhaodi;
Ade, Peter;
Ahmed, Zeeshan;
Adam, Anderson;
Austermann, Jason;
Avva, Jessica;
Thakur, Ritoban Basu;
Amy, Bender;
Benson, Bradford;
Carlstrom, John;
Carter, Faustin;
Cecil, Thomas;
Chang, Clarence;
Cliche, Jean-Francois;
Cukierman, Ariel;
Denison, Edward;
de Haan, Tijmen;
Ding, Junjia;
Dobbs, Matt;
Dutcher, Daniel;
Everett, Wendeline;
Foster, Allen;
Gannon, Renae;
Gilbert, Adam;
Groh, John;
Halverson, Nils;
Harke-Horsemann, Angelina;
Harrington, Nicholas;
Henning, Jaosn;
Hilton, Gene;
Holzapfel, William;
Huang, Nicholas;
Irwin, Kent;
Jeong, Oliver;
Jonas, Michalle;
Khaire, Trupti;
Kofman, Anna;
Korman, Milo;
Kubik, Donna;
Kuhlmann, Steve;
Kuo, Chaolin;
Lee, Adrian;
Lowitz, Amy;
Meyer, Stephan;
Michalik, Daniel;
Montgomery, Joshua;
Nadolski, Andrew;
Natoli, Tyler;
Nguyen, Hogan;
Noble, Gavin;
Novosad, Valentyn;
Padin, Stephan;
Pearson, John;
Posada, Chrystian;
Rahlin, Alexandra;
Ruhl, John;
Saunders, Lauren;
Sayre, James;
Shirley, Ian;
Shirokoff, Erik;
Smecher, Graeme;
Sobrin, Joshua;
Stark, Antony;
Story, Kyle;
Suzuki, Aritoki;
Tang, Qingyang;
Thompson, Keith;
Tucker, Carole;
Vale, Leila;
Vanderlinde, Keith;
Vieira, Joaquin;
Wang, Gensheng;
Whitehorn, Nathan;
Yefremenko, Volodymyr;
Yoon, Ki Won;
Young, Matt
Submitted: 2018-05-08
The third-generation South Pole Telescope camera is designed to measure the
cosmic microwave background across three frequency bands (95, 150 and 220 GHz)
with ~16,000 transition-edge sensor (TES) bolometers. Each multichroic pixel on
a detector wafer has a broadband sinuous antenna that couples power to six
TESs, one for each of the three observing bands and both polarization
directions, via lumped element filters. Ten detector wafers populate the focal
plane, which is coupled to the sky via a large-aperture optical system. Here we
present the frequency band characterization with Fourier transform
spectroscopy, measurements of optical time constants, beam properties, and
optical and polarization efficiencies of the focal plane. The detectors have
frequency bands consistent with our simulations, and have high average optical
efficiency which is 86%, 77% and 66% for the 95, 150 and 220 GHz detectors. The
time constants of the detectors are mostly between 0.5 ms and 5 ms. The beam is
round with the correct size, and the polarization efficiency is more than 90%
for most of the bolometers
[3]
oai:arXiv.org:1608.03025 [pdf] - 1531238
POLARBEAR-2: an instrument for CMB polarization measurements
Inoue, Y.;
Ade, P.;
Akiba, Y.;
Aleman, C.;
Arnold, K.;
Baccigalupi, C.;
Barch, B.;
Barron, D.;
Bender, A.;
Boettger, D.;
Borrill, J.;
Chapman, S.;
Chinone, Y.;
Cukierman, A.;
de Haan, T.;
Dobbs, M. A.;
Ducout, A.;
Dunner, R.;
Elleflot, T.;
Errard, J.;
Fabbian, G.;
Feeney, S.;
Feng, C.;
Fuller, G.;
Gilbert, A. J.;
Goeckner-Wald, N.;
Groh, J.;
Hall, G.;
Halverson, N.;
Hamada, T.;
Hasegawa, M.;
Hattori, K.;
Hazumi, M.;
Hill, C.;
Holzapfel, W. L.;
Hori, Y.;
Howe, L.;
Irie, F.;
Jaehnig, G.;
Jaffe, A.;
Jeongh, O.;
Katayama, N.;
Kaufman, J. P.;
Kazemzadeh, K.;
Keating, B. G.;
Kermish, Z.;
Keskital, R.;
Kisner, T.;
Kusaka, A.;
Jeune, M. Le;
Lee, A. T.;
Leon, D.;
Linder, E. V.;
Lowry, L.;
Matsuda, F.;
Matsumura, T.;
Miller, N.;
Mizukami, K.;
Montgomery, J.;
Navaroli, M.;
Nishino, H.;
Paar, H.;
Peloton, J.;
Poletti, D.;
Puglisi, G.;
Raum, C. R.;
Rebeiz, G. M.;
Reichardt, C. L.;
Richards, P. L.;
Ross, C.;
Rotermund, K. M.;
Segaw, Y.;
Sherwin, B. D.;
Shirley, I.;
Siritanasak, P.;
Stebor, N.;
Suzuki, R. Stompor A.;
Tajima, O.;
Takada, S.;
Takatori, S.;
Teply, G. P.;
Tikhomirol, A.;
Tomaru, T.;
Whitehorn, N.;
Zahn, A.;
Zahn, O.
Submitted: 2016-08-09
POLARBEAR-2 (PB-2) is a cosmic microwave background (CMB) polarization
experiment that will be located in the Atacama highland in Chile at an altitude
of 5200 m. Its science goals are to measure the CMB polarization signals
originating from both primordial gravitational waves and weak lensing. PB-2 is
designed to measure the tensor to scalar ratio, r, with precision {\sigma}(r) <
0.01, and the sum of neutrino masses, {\Sigma}m{\nu}, with
{\sigma}({\Sigma}m{\nu}) < 90 meV. To achieve these goals, PB-2 will employ
7588 transition-edge sensor bolometers at 95 GHz and 150 GHz, which will be
operated at the base temperature of 250 mK. Science observations will begin in
2017.
[4]
oai:arXiv.org:1509.02461 [pdf] - 1335455
POLARBEAR Constraints on Cosmic Birefringence and Primordial Magnetic
Fields
POLARBEAR Collaboration;
Ade, Peter A. R.;
Arnold, Kam;
Atlas, Matt;
Baccigalupi, Carlo;
Barron, Darcy;
Boettger, David;
Borrill, Julian;
Chapman, Scott;
Chinone, Yuji;
Cukierman, Ari;
Dobbs, Matt;
Ducout, Anne;
Dunner, Rolando;
Elleflot, Tucker;
Errard, Josquin;
Fabbian, Giulio;
Feeney, Stephen;
Feng, Chang;
Gilbert, Adam;
Goeckner-Wald, Neil;
Groh, John;
Hall, Grantland;
Halverson, Nils W.;
Hasegawa, Masaya;
Hattori, Kaori;
Hazumi, Masashi;
Hill, Charles;
Holzapfel, William L.;
Hori, Yasuto;
Howe, Logan;
Inoue, Yuki;
Jaehnig, Gregory C.;
Jaffe, Andrew H.;
Jeong, Oliver;
Katayama, Nobuhiko;
Kaufman, Jonathan P.;
Keating, Brian;
Kermish, Zigmund;
Keskitalo, Reijo;
Kisner, Theodore;
Kusaka, Akito;
Jeune, Maude Le;
Lee, Adrian T.;
Leitch, Erik M.;
Leon, David;
Li, Yun;
Linder, Eric;
Lowry, Lindsay;
Matsuda, Frederick;
Matsumura, Tomotake;
Miller, Nathan;
Montgomery, Josh;
Myers, Michael J.;
Navaroli, Martin;
Nishino, Haruki;
Okamura, Takahiro;
Paar, Hans;
Peloton, Julien;
Pogosian, Levon;
Poletti, Davide;
Puglisi, Giuseppe;
Raum, Christopher;
Rebeiz, Gabriel;
Reichardt, Christian L.;
Richards, Paul L.;
Ross, Colin;
Rotermund, Kaja M.;
Schenck, David E.;
Sherwin, Blake D.;
Shimon, Meir;
Shirley, Ian;
Siritanasak, Praween;
Smecher, Graeme;
Stebor, Nathan;
Steinbach, Bryan;
Suzuki, Aritoki;
Suzuki, Jun-ichi;
Tajima, Osamu;
Takakura, Satoru;
Tikhomirov, Alexei;
Tomaru, Takayuki;
Whitehorn, Nathan;
Wilson, Brandon;
Yadav, Amit;
Zahn, Alex;
Zahn, Oliver
Submitted: 2015-09-08, last modified: 2016-01-04
We constrain anisotropic cosmic birefringence using four-point correlations
of even-parity $E$-mode and odd-parity $B$-mode polarization in the cosmic
microwave background measurements made by the POLARization of the Background
Radiation (POLARBEAR) experiment in its first season of observations. We find
that the anisotropic cosmic birefringence signal from any parity-violating
processes is consistent with zero. The Faraday rotation from anisotropic cosmic
birefringence can be compared with the equivalent quantity generated by
primordial magnetic fields if they existed. The POLARBEAR nondetection
translates into a 95% confidence level (C.L.) upper limit of 93 nanogauss (nG)
on the amplitude of an equivalent primordial magnetic field inclusive of
systematic uncertainties. This four-point correlation constraint on Faraday
rotation is about 15 times tighter than the upper limit of 1380 nG inferred
from constraining the contribution of Faraday rotation to two-point
correlations of $B$-modes measured by Planck in 2015. Metric perturbations
sourced by primordial magnetic fields would also contribute to the $B$-mode
power spectrum. Using the POLARBEAR measurements of the $B$-mode power spectrum
(two-point correlation), we set a 95% C.L. upper limit of 3.9 nG on primordial
magnetic fields assuming a flat prior on the field amplitude. This limit is
comparable to what was found in the Planck 2015 two-point correlation analysis
with both temperature and polarization. We perform a set of systematic error
tests and find no evidence for contamination. This work marks the first time
that anisotropic cosmic birefringence or primordial magnetic fields have been
constrained from the ground at subdegree scales.
[5]
oai:arXiv.org:1512.07663 [pdf] - 1359112
Development of readout electronics for POLARBEAR-2 Cosmic Microwave
Background experiment
Hattori, K.;
Akiba, Y.;
Arnold, K.;
Barron, D.;
Bender, A. N.;
Cukierman, A.;
de Haan, T.;
Dobbs, M.;
Elleflot, T.;
Hasegawa, M.;
Hazumi, M.;
Holzapfel, W.;
Hori, Y.;
Keating, B.;
Kusaka, A.;
Lee, A.;
Montgomery, J.;
Rotermund, K.;
Shirley, I.;
Suzuki, A.;
Whitehorn, N.
Submitted: 2015-12-23
The readout of transition-edge sensor (TES) bolometers with a large
multiplexing factor is key for the next generation Cosmic Microwave Background
(CMB) experiment, Polarbear-2, having 7,588 TES bolometers. To enable the large
arrays, we have been developing a readout system with a multiplexing factor of
40 in the frequency domain. Extending that architecture to 40 bolometers
requires an increase in the bandwidth of the SQUID electronics above 4 MHz.
This paper focuses on cryogenic readout and shows how it affects cross talk and
the responsivity of the TES bolometers. A series resistance, such as equivalent
series resistance (ESR) of capacitors for LC filters, leads to non-linear
response of the bolometers. A wiring inductance modulates a voltage across the
bolometers and causes cross talk. They should be controlled well to reduce
systematic errors in CMB observations. We have been developing a cryogenic
readout with a low series impedance and have tuned bolometers in the middle of
their transition at a high frequency (> 3 MHz).
[6]
oai:arXiv.org:1512.07299 [pdf] - 1359106
The POLARBEAR-2 and the Simons Array Experiment
Suzuki, A.;
Ade, P.;
Akiba, Y.;
Aleman, C.;
Arnold, K.;
Baccigalupi, C.;
Barch, B.;
Barron, D.;
Bender, A.;
Boettger, D.;
Borrill, J.;
Chapman, S.;
Chinone, Y.;
Cukierman, A.;
Dobbs, M.;
Ducout, A.;
Dunner, R.;
Elleflot, T.;
Errard, J.;
Fabbian, G.;
Feeney, S.;
Feng, C.;
Fujino, T.;
Fuller, G.;
Gilbert, A.;
Goeckner-Wald, N.;
Groh, J.;
De Haan, T.;
Hall, G.;
Halverson, N.;
Hamada, T.;
Hasegawa, M.;
Hattori, K.;
Hazumi, M.;
Hill, C.;
Holzapfel, W.;
Hori, Y.;
Howe, L.;
Inoue, Y.;
Irie, F.;
Jaehnig, G.;
Jaffe, A.;
Jeong, O.;
Katayama, N.;
Kaufman, J.;
Kazemzadeh, K.;
Keating, B.;
Kermish, Z.;
Keskitalo, R.;
Kisner, T.;
Kusaka, A.;
Jeune, M. Le;
Lee, A.;
Leon, D.;
Linder, E.;
Lowry, L.;
Matsuda, F.;
Matsumura, T.;
Miller, N.;
Mizukami, K.;
Montgomery, J.;
Navaroli, M.;
Nishino, H.;
Peloton, J.;
Poletti, D.;
Rebeiz, G.;
Raum, C.;
Reichardt, C.;
Richards, P.;
Ross, C.;
Rotermund, K.;
Segawa, Y.;
Sherwin, B.;
Shirley, I.;
Siritanasak, P.;
Stebor, N.;
Stompor, R.;
Suzuki, J.;
Tajima, O.;
Takada, S.;
Takakura, S.;
Takatori, S.;
Tikhomirov, A.;
Tomaru, T.;
Westbrook, B.;
Whitehorn, N.;
Yamashita, T.;
Zahn, A.;
Zahn, O.
Submitted: 2015-12-22
We present an overview of the design and status of the \Pb-2 and the Simons
Array experiments. \Pb-2 is a Cosmic Microwave Background polarimetry
experiment which aims to characterize the arc-minute angular scale B-mode
signal from weak gravitational lensing and search for the degree angular scale
B-mode signal from inflationary gravitational waves. The receiver has a 365~mm
diameter focal plane cooled to 270~milli-Kelvin. The focal plane is filled with
7,588 dichroic lenslet-antenna coupled polarization sensitive Transition Edge
Sensor (TES) bolometric pixels that are sensitive to 95~GHz and 150~GHz bands
simultaneously. The TES bolometers are read-out by SQUIDs with 40 channel
frequency domain multiplexing. Refractive optical elements are made with high
purity alumina to achieve high optical throughput. The receiver is designed to
achieve noise equivalent temperature of 5.8~$\mu$K$_{CMB}\sqrt{s}$ in each
frequency band. \Pb-2 will deploy in 2016 in the Atacama desert in Chile. The
Simons Array is a project to further increase sensitivity by deploying three
\Pb-2 type receivers. The Simons Array will cover 95~GHz, 150~GHz and 220~GHz
frequency bands for foreground control. The Simons Array will be able to
constrain tensor-to-scalar ratio and sum of neutrino masses to $\sigma(r) =
6\times 10^{-3}$ at $r = 0.1$ and $\sum m_\nu (\sigma =1)$ to 40 meV.
[7]
oai:arXiv.org:1410.7488 [pdf] - 894214
Development and characterization of the readout system for POLARBEAR-2
Barron, D.;
Ade, P. A. R.;
Akiba, Y.;
Aleman, C.;
Arnold, K.;
Atlas, M.;
Bender, A.;
Boettger, D.;
Borrill, J.;
Chapman, S.;
Chinone, Y.;
Cukierman, A.;
Dobbs, M.;
Elleflot, T.;
Errard, J.;
Fabbian, G.;
Feng, C.;
Gilbert, A.;
Goeckner-Wald, N.;
Halverson, N. W.;
Hasegawa, M.;
Hattori, K.;
Hazumi, M.;
Holzapfel, W. L.;
Hori, Y.;
Inoue, Y.;
Jaehnig, G. C.;
Jaffe, A. H.;
Katayama, N.;
Keating, B.;
Kermish, Z.;
Keskitalo, R.;
Kisner, T.;
Jeune, M. Le;
Lee, A. T.;
Leitch, E. M.;
Linder, E.;
Matsuda, F.;
Matsumura, T.;
Meng, X.;
Morii, H.;
Myers, M. J.;
Navaroli, M.;
Nishino, H.;
Okamura, T.;
Paar, H.;
Peloton, J.;
Poletti, D.;
Raum, C.;
Rebeiz, G.;
Reichardt, C. L.;
Richards, P. L.;
Ross, C.;
Rotermund, K.;
Schenck, D. E.;
Sherwin, B. D.;
Shirley, I.;
Sholl, M.;
Siritanasak, P.;
Smecher, G.;
Stebor, N.;
Steinbach, B.;
Stompor, R.;
Suzuki, A.;
Suzuki, J.;
Takada, S.;
Takakura, S.;
Tomaru, T.;
Wilson, B.;
Yadav, A.;
Yamaguchi, H.;
Zahn, O.
Submitted: 2014-10-27, last modified: 2014-11-06
POLARBEAR-2 is a next-generation receiver for precision measurements of the
polarization of the cosmic microwave background (Cosmic Microwave Background
(CMB)). Scheduled to deploy in early 2015, it will observe alongside the
existing POLARBEAR-1 receiver, on a new telescope in the Simons Array on Cerro
Toco in the Atacama desert of Chile. For increased sensitivity, it will feature
a larger area focal plane, with a total of 7,588 polarization sensitive
antenna-coupled Transition Edge Sensor (TES) bolometers, with a design
sensitivity of 4.1 uKrt(s). The focal plane will be cooled to 250 milliKelvin,
and the bolometers will be read-out with 40x frequency domain multiplexing,
with 36 optical bolometers on a single SQUID amplifier, along with 2 dark
bolometers and 2 calibration resistors. To increase the multiplexing factor
from 8x for POLARBEAR-1 to 40x for POLARBEAR-2 requires additional bandwidth
for SQUID readout and well-defined frequency channel spacing. Extending to
these higher frequencies requires new components and design for the LC filters
which define channel spacing. The LC filters are cold resonant circuits with an
inductor and capacitor in series with each bolometer, and stray inductance in
the wiring and equivalent series resistance from the capacitors can affect
bolometer operation. We present results from characterizing these new readout
components. Integration of the readout system is being done first on a small
scale, to ensure that the readout system does not affect bolometer sensitivity
or stability, and to validate the overall system before expansion into the full
receiver. We present the status of readout integration, and the initial results
and status of components for the full array.