Normalized to: Shemyakina, E.
[1]
oai:arXiv.org:1909.00619 [pdf] - 1953832
Electron transport and electric field simulations in two-phase detectors
with THGEM electrodes
Submitted: 2019-09-02
One of the main features of two-phase detectors with electroluminescence (EL)
gap being developed in our laboratory for dark matter search is the extensive
use of THGEMs (Thick Gas Electron Multipliers). In various versions of the
detector, the THGEMs are used as electrodes in the gas and liquid phases to
form the drift, electron emission and EL regions, as well as for avalanche
amplification of a signal in the gas phase. In this work the simulations of the
electric field and electron transport through such THGEM electrodes were
performed. In the liquid phase, these simulations allowed to determine the
optimal parameters, such as the hole diameter of THGEM and applied voltage
across it, that can provide effective transmission of the electrons from the
drift region to that of the EL gap. In the gas phase, the effect of the THGHEM
voltage on the electric field uniformity in the EL gap was studied.
[2]
oai:arXiv.org:1905.05502 [pdf] - 2052567
Neutral bremsstrahlung in two-phase argon electroluminescence: further
studies and possible applications
Submitted: 2019-05-14
We further study the effect of neutral bremsstrahlung (NBrS) in two-phase
argon electroluminescence (EL), revealed recently in [1]. The absolute EL yield
due to NBrS effect, in the visible and NIR range, was remeasured in pure
gaseous argon in the two-phase mode, using a two-phase detector with EL gap
read out directly by cryogenic PMTs and SiPMs. Possible applications of the
NBrS effect in detection science are discussed, including those in two-phase
dark matter detectors.
[3]
oai:arXiv.org:1803.05329 [pdf] - 1712914
Revealing neutral bremsstrahlung in two-phase argon electroluminescence
Submitted: 2018-03-13, last modified: 2018-06-20
Proportional electroluminescence (EL) in noble gases has long been used in
two-phase detectors for dark matter search, to record ionization signals
induced by particle scattering in the noble-gas liquid (S2 signals). Until
recently, it was believed that proportional electroluminescence was fully due
to VUV emission of noble gas excimers produced in atomic collisions with
excited atoms, the latter being in turn produced by drifting electrons. In this
work we consider an additional mechanism of proportional electroluminescence,
namely that of bremsstrahlung of drifting electrons scattered on neutral atoms
(so-called neutral bremsstrahlung); it is systemically studied here both
theoretically and experimentally. In particular, the absolute EL yield has for
the first time been measured in pure gaseous argon in the two-phase mode, using
a dedicated two-phase detector with EL gap optically read out by cryogenic PMTs
and SiPMs. We show that the neutral bremsstrahlung effect can explain two
intriguing observations in EL radiation: that of the substantial contribution
of the non-VUV spectral component, extending from the UV to NIR, and that of
the photon emission at lower electric fields, below the Ar excitation
threshold. Possible applications of neutral bremsstrahlung effect in two-phase
dark matter detectors are discussed.
[4]
oai:arXiv.org:1705.05101 [pdf] - 1583416
Further studies of proportional electroluminescence in two-phase argon
Submitted: 2017-05-15
The study of proportional electroluminescence in two-phase argon is relevant
in the field of noble-gas liquid detectors for dark matter search and
low-energy neutrino experiments. In this work, we continued to study
proportional electroluminescence (EL) in two-phase argon doped with a minor (9
ppm) admixture of nitrogen, in the VUV, UV and visible spectral ranges. We
confirmed the effect of enhancement of the EL yield, as well as the presence of
non-VUV component in addition to that of VUV, in proportional
electroluminescence in two-phase Ar. On the other hand, the contribution of
non-VUV component determined here within the model of N2 emission in the UV,
turned out to be insufficient to explain the EL yield enhancement effect.
Accordingly, the problem of proportional electroluminescence in two-phase Ar
remains unresolved.
[5]
oai:arXiv.org:1705.05107 [pdf] - 1583417
Measurement of the ionization yield of nuclear recoils in liquid argon
using a two-phase detector with electroluminescence gap
Bondar, A.;
Buzulutskov, A.;
Dolgov, A.;
Grishnyaev, E.;
Nosov, V.;
Oleynikov, V.;
Polosatkin, S.;
Shekhtman, L.;
Shemyakina, E.;
Sokolov, A.
Submitted: 2017-05-15
A measurement of ionization yields in noble-gas liquids is relevant to the
energy calibration of nuclear recoil detectors for dark matter search and
coherent neutrino-nucleus scattering experiments. In this work we further study
the ionization yield of nuclear recoils in liquid Ar, using a two-phase
detector with an electroluminescence gap and DD neutron generator. The
ionization yields of nuclear recoils in liquid Ar were measured at 233 keV and
electric fields of 0.56 and 0.62 kV/cm; their values amounted to 5.9 $\pm$ 0.8
and 7.4 $\pm$ 1 e$^-$/keV, respectively. The characteristic dependences of the
ionization yield on energy and electric field were determined, while comparing
the results obtained to those at lower energies and higher fields.