sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Shelton, Chris

Normalized to: Shelton, C.

3 article(s) in total. 31 co-authors. Median position in authors list is 4,0.

[1]  oai:arXiv.org:2006.07343  [pdf] - 2113453
Automated Measurement of Quasar Redshift with a Gaussian Process
Comments: 13 pages, 11 figures, to be submitted to MNRAS
Submitted: 2020-06-12
We develop an automated technique to measure quasar redshifts in the Baryon Oscillation Spectroscopic Survey (BOSS) of the Sloan Digital Sky Survey (SDSS). Our technique is an extension of an earlier Gaussian process method for detecting damped Lyman-alpha absorbers (DLAs) in quasar spectra with known redshifts. We show that we are competitive to existing quasar redshift estimators. Importantly our method produces a probabilistic density function for the quasar redshift, allowing quasar redshift uncertainty to be propagated to downstream users. We apply this method to detecting DLAs, accounting in a Bayesian fashion for redshift uncertainty. Compared to our earlier method with a known quasar redshift, we have only a moderate decrease in our ability to detect DLAs, predominantly in the noisiest spectra. Our code is publicly available.
[2]  oai:arXiv.org:1012.0008  [pdf] - 1042291
A New High Contrast Imaging Program at Palomar Observatory
Comments: Accepted to PASP: 12 pages, 12 figures
Submitted: 2010-11-30
We describe a new instrument that forms the core of a long-term high contrast imaging program at the 200-inch Hale Telescope at Palomar Observatory. The primary scientific thrust is to obtain images and low-resolution spectroscopy of brown dwarfs and young Jovian mass exoplanets in the vicinity of stars within 50 parsecs of the Sun. The instrument is a microlens-based integral field spectrograph integrated with a diffraction limited, apodized-pupil Lyot coronagraph, mounted behind the Palomar adaptive optics system. The spectrograph obtains imaging in 23 channels across the J and H bands (1.06 - 1.78 microns). In addition to obtaining spectra, this wavelength resolution allows suppression of the chromatically dependent speckle noise, which we describe. We have recently installed a novel internal wave front calibration system that will provide continuous updates to the AO system every 0.5 - 1.0 minutes by sensing the wave front within the coronagraph. The Palomar AO system is undergoing an upgrade to a much higher-order AO system ("PALM-3000"): a 3388-actuator tweeter deformable mirror working together with the existing 241-actuator mirror. This system will allow correction with subapertures as small as 8cm at the telescope pupil using natural guide stars. The coronagraph alone has achieved an initial dynamic range in the H-band of 2 X 10^-4 at 1 arcsecond, without speckle noise suppression. We demonstrate that spectral speckle suppression is providing a factor of 10-20 improvement over this bringing our current contrast at an arcsecond to ~2 X 10^-5. This system is the first of a new generation of apodized pupil coronagraphs combined with high-order adaptive optics and integral field spectrographs (e.g. GPI, SPHERE, HiCIAO), and we anticipate this instrument will make a lasting contribution to high contrast imaging in the Northern Hemisphere for years.
[3]  oai:arXiv.org:astro-ph/9708103  [pdf] - 1235072
Adaptive Optics Spectroscopy: Preliminary Theoretical Results
Comments: Proceeding SPIE Conference on Adaptive Optics and Applications, 1997, 3126, in press, 12 pages and 6 figs included, also available at http://qso.as.arizona.edu/~jge/projects.html
Submitted: 1997-08-12
We have done theoretical calculations and simulations for infrared spectroscopy at the MMT 6.5 m with laser guide star AO, which provides almost full sky coverage. The results show we can expect 40-60% of the photons from a unresolved source within 0.2 arcsec diameter circle for J, H, K, L and M bands under typical atmospheric seeing condition at 2.2 micron. Therefore, the spectrograph entrance slit size should match the 0.2 arcsec image to obtain high throughput. Higher resolution can be achieved by narrowing down the slit size to match the diffraction-limited image core size of about 0.1 arcsec in the infrared. However, the throughput will be correspondingly reduced by a factor of two. Due to the limited atmospheric isoplanatic angle in the J, H and K bands, the encircled photon percentage within 0.2 arcsec diameter drops from 40-60% when the object is at the laser pointing direction to 20-40% when the object is about 30 arcsec away from the laser direction. Therefore, the useful field of view for AO multiple object spectroscopy is about 60 arcsec. Further studies of IR background (sky and thermal) and IR detector performance show that spectral resolution of R = 2,000 can take full advantage of AO images without much penalty due to the dark current of the IR detector and IR OH sky emission lines. We have also studied natural guide star AO spectroscopy. More details are in the paper.