Normalized to: Shekhtman, L.
[1]
oai:arXiv.org:1803.05329 [pdf] - 1712914
Revealing neutral bremsstrahlung in two-phase argon electroluminescence
Submitted: 2018-03-13, last modified: 2018-06-20
Proportional electroluminescence (EL) in noble gases has long been used in
two-phase detectors for dark matter search, to record ionization signals
induced by particle scattering in the noble-gas liquid (S2 signals). Until
recently, it was believed that proportional electroluminescence was fully due
to VUV emission of noble gas excimers produced in atomic collisions with
excited atoms, the latter being in turn produced by drifting electrons. In this
work we consider an additional mechanism of proportional electroluminescence,
namely that of bremsstrahlung of drifting electrons scattered on neutral atoms
(so-called neutral bremsstrahlung); it is systemically studied here both
theoretically and experimentally. In particular, the absolute EL yield has for
the first time been measured in pure gaseous argon in the two-phase mode, using
a dedicated two-phase detector with EL gap optically read out by cryogenic PMTs
and SiPMs. We show that the neutral bremsstrahlung effect can explain two
intriguing observations in EL radiation: that of the substantial contribution
of the non-VUV spectral component, extending from the UV to NIR, and that of
the photon emission at lower electric fields, below the Ar excitation
threshold. Possible applications of neutral bremsstrahlung effect in two-phase
dark matter detectors are discussed.
[2]
oai:arXiv.org:1705.05101 [pdf] - 1583416
Further studies of proportional electroluminescence in two-phase argon
Submitted: 2017-05-15
The study of proportional electroluminescence in two-phase argon is relevant
in the field of noble-gas liquid detectors for dark matter search and
low-energy neutrino experiments. In this work, we continued to study
proportional electroluminescence (EL) in two-phase argon doped with a minor (9
ppm) admixture of nitrogen, in the VUV, UV and visible spectral ranges. We
confirmed the effect of enhancement of the EL yield, as well as the presence of
non-VUV component in addition to that of VUV, in proportional
electroluminescence in two-phase Ar. On the other hand, the contribution of
non-VUV component determined here within the model of N2 emission in the UV,
turned out to be insufficient to explain the EL yield enhancement effect.
Accordingly, the problem of proportional electroluminescence in two-phase Ar
remains unresolved.
[3]
oai:arXiv.org:1705.05107 [pdf] - 1583417
Measurement of the ionization yield of nuclear recoils in liquid argon
using a two-phase detector with electroluminescence gap
Bondar, A.;
Buzulutskov, A.;
Dolgov, A.;
Grishnyaev, E.;
Nosov, V.;
Oleynikov, V.;
Polosatkin, S.;
Shekhtman, L.;
Shemyakina, E.;
Sokolov, A.
Submitted: 2017-05-15
A measurement of ionization yields in noble-gas liquids is relevant to the
energy calibration of nuclear recoil detectors for dark matter search and
coherent neutrino-nucleus scattering experiments. In this work we further study
the ionization yield of nuclear recoils in liquid Ar, using a two-phase
detector with an electroluminescence gap and DD neutron generator. The
ionization yields of nuclear recoils in liquid Ar were measured at 233 keV and
electric fields of 0.56 and 0.62 kV/cm; their values amounted to 5.9 $\pm$ 0.8
and 7.4 $\pm$ 1 e$^-$/keV, respectively. The characteristic dependences of the
ionization yield on energy and electric field were determined, while comparing
the results obtained to those at lower energies and higher fields.
[4]
oai:arXiv.org:1705.01250 [pdf] - 1583058
Study of cryogenic photomultiplier tubes for the future two-phase
cryogenic avalanche detector
Submitted: 2017-05-03
We report the results of a characterization study of several types of
cryogenic photomultipliers manufactured by Hamamatsu Photonics and intended for
operation in liquid Ar conditions, namely: compact 2-inch R6041-506MOD tubes,
3-inch R11065-10 and R11065-MOD tubes for operation in liquid Ar and 3-inch
R11410-20 tubes originally designed for operation in liquid Xe. These types of
PMT are proposed for installation into the future two-phase cryogenic avalanche
detector that is developed in the Laboratory of Cosmology and Particle Physics
of the Novosibirsk State University jointly with the Budker Institute of
Nuclear Physics. Eight R11065 PMTs and seven R11410-20 tubes were tested and
all demonstrated excellent performance in liquid Ar in terms of gain and
relative single electron efficiency. All 3-inch PMTs showed a maximal gain in
liquid Ar above 5x10^6 and relative single electron efficiency higher than 95%.
Compact R6041-506MOD tubes have dynode system different from that of the 3-inch
photomultipliers and thus their single electron energy resolution and relative
efficiency is much worse than that of 3-inch tubes. From 21 2-inch PMTs only 12
tubes were selected with acceptable, i.e. higher than 75%, relative single
electron efficiency and the maximal gain higher than 5x10^6. However, these
PMTs are very attractive because they are the only compact type of tubes that
can operate in liquid Ar.
[5]
oai:arXiv.org:1112.0574 [pdf] - 1092135
Thermal Phase Variations of WASP-12b: Defying Predictions
Submitted: 2011-12-02, last modified: 2012-01-26
[Abridged] We report Warm Spitzer full-orbit phase observations of WASP-12b
at 3.6 and 4.5 micron. We are able to measure the transit depths, eclipse
depths, thermal and ellipsoidal phase variations at both wavelengths. The large
amplitude phase variations, combined with the planet's previously-measured
day-side spectral energy distribution, is indicative of non-zero Bond albedo
and very poor day-night heat redistribution. The transit depths in the
mid-infrared indicate that the atmospheric opacity is greater at 3.6 than at
4.5 micron, in disagreement with model predictions, irrespective of C/O ratio.
The secondary eclipse depths are consistent with previous studies. We do not
detect ellipsoidal variations at 3.6 micron, but our parameter uncertainties
-estimated via prayer-bead Monte Carlo- keep this non-detection consistent with
model predictions. At 4.5 micron, on the other hand, we detect ellipsoidal
variations that are much stronger than predicted. If interpreted as a geometric
effect due to the planet's elongated shape, these variations imply a 3:2 ratio
for the planet's longest:shortest axes and a relatively bright day-night
terminator. If we instead presume that the 4.5 micron ellipsoidal variations
are due to uncorrected systematic noise and we fix the amplitude of the
variations to zero, the best fit 4.5 micron transit depth becomes commensurate
with the 3.6 micron depth, within the uncertainties. The relative transit
depths are then consistent with a Solar composition and short scale height at
the terminator. Assuming zero ellipsoidal variations also yields a much deeper
4.5 micron eclipse depth, consistent with a Solar composition and modest
temperature inversion. We suggest future observations that could distinguish
between these two scenarios.