Normalized to: Shaw, E.
[1]
oai:arXiv.org:2002.05771 [pdf] - 2080996
Particle response of antenna-coupled TES arrays: results from SPIDER and
the lab
Osherson, B.;
Filippini, J. P.;
Fu, J.;
Gramillano, R. V.;
Gualtieri, R.;
Shaw, E. C.;
Ade, P. A. R.;
Amiri, M.;
Benton, S. J.;
Bock, J. J.;
Bond, J. R.;
Bryan, S. A.;
Chiang, H. C.;
Contaldi, C. R.;
Dore, O.;
Fraisse, A. A.;
Gambrel, A. E.;
Gandilo, N. N.;
Gudmundsson, J. E.;
Halpern, M.;
Hartley, J.;
Hasselfield, M.;
Hilton, G.;
Holmes, W.;
Hristov, V. V.;
Irwin, K. D.;
Jones, W. C.;
Kermish, Z. D.;
Mason, P. V.;
Megerian, K.;
Moncelsi, L.;
Morford, T. A.;
Nagy, J. M.;
Netterfield, C. B.;
Padilla, I. L.;
Rahlin, A. S.;
Reintsema, C.;
Ruhl, J. E.;
Runyan, M. C.;
Shariff, J. A.;
Soler, J. D.;
Trangsrud, A.;
Tucker, C.;
Tucker, R. S.;
Turner, A. D.;
Weber, A. C.;
Wiebe, D. V.;
Young, E. Y.
Submitted: 2020-02-13
Future mm-wave and sub-mm space missions will employ large arrays of
multiplexed Transition Edge Sensor (TES) bolometers. Such instruments must
contend with the high flux of cosmic rays beyond our atmosphere that induce
"glitches" in bolometer data, which posed a challenge to data analysis from the
Planck bolometers. Future instruments will face the additional challenges of
shared substrate wafers and multiplexed readout wiring. In this work we explore
the susceptibility of modern TES arrays to the cosmic ray environment of space
using two data sets: the 2015 long-duration balloon flight of the SPIDER cosmic
microwave background polarimeter, and a laboratory exposure of SPIDER flight
hardware to radioactive sources. We find manageable glitch rates and short
glitch durations, leading to minimal effect on SPIDER analysis. We constrain
energy propagation within the substrate through a study of multi-detector
coincidences, and give a preliminary look at pulse shapes in laboratory data.
[2]
oai:arXiv.org:1711.04169 [pdf] - 1755845
280 GHz Focal Plane Unit Design and Characterization for the SPIDER-2
Suborbital Polarimeter
Bergman, A. S.;
Ade, P. A. R.;
Akers, S.;
Amiri, M.;
Austermann, J. A.;
Beall, J. A.;
Becker, D. T.;
Benton, S. J.;
Bock, J. J.;
Bond, J. R.;
Bryan, S. A.;
Chiang, H. C.;
Contaldi, C. R.;
Domagalski, R. S;
Doré, O.;
Duff, S. M.;
Duivenvoorden, A. J.;
Eriksen, H. K.;
Farhang, M.;
Filippini, J. P.;
Fissel, L. M.;
Fraisse, A. A.;
Freese, K.;
Galloway, M.;
Gambrel, A. E.;
Gandilo, N. N.;
Ganga, K.;
Grigorian, A.;
Gualtieri, R.;
Gudmundsson, J. E.;
Halpern, M.;
Hartley, J.;
Hasselfield, M.;
Hilton, G.;
Holmes, W.;
Hristov, V. V.;
Huang, Z.;
Hubmayr, J.;
Irwin, K. D.;
Jones, W. C.;
Khan, A.;
Kuo, C. L.;
Kermish, Z. D.;
Li, S.;
Mason, P. V.;
Megerian, K.;
Moncelsi, L.;
Morford, T. A.;
Nagy, J. M.;
Netterfield, C. B.;
Nolta, M.;
Osherson, B.;
Padilla, I. L.;
Racine, B.;
Rahlin, A. S.;
Redmond, S.;
Reintsema, C.;
Romualdez, L. J.;
Ruhl, J. E.;
Runyan, M. C.;
Ruud, T. M.;
Shariff, J. A.;
Shaw, E. C.;
Shiu, C.;
Soler, J. D.;
Song, X.;
Trangsrud, A.;
Tucker, C.;
Tucker, R. S.;
Turner, A. D.;
Ullom, J.;
van der List, J. F.;
Van Lanen, J.;
Vissers, M. R.;
Weber, A. C.;
Wehus, I. K.;
Wen, S.;
Wiebe, D. V.;
Young, E. Y.
Submitted: 2017-11-11, last modified: 2017-11-22
We describe the construction and characterization of the 280 GHz bolometric
focal plane units (FPUs) to be deployed on the second flight of the
balloon-borne SPIDER instrument. These FPUs are vital to SPIDER's primary
science goal of detecting or placing an upper limit on the amplitude of the
primordial gravitational wave signature in the cosmic microwave background
(CMB) by constraining the B-mode contamination in the CMB from Galactic dust
emission. Each 280 GHz focal plane contains a 16 x 16 grid of corrugated
silicon feedhorns coupled to an array of aluminum-manganese transition-edge
sensor (TES) bolometers fabricated on 150 mm diameter substrates. In total, the
three 280 GHz FPUs contain 1,530 polarization sensitive bolometers (765 spatial
pixels) optimized for the low loading environment in flight and read out by
time-division SQUID multiplexing. In this paper we describe the mechanical,
thermal, and magnetic shielding architecture of the focal planes and present
cryogenic measurements which characterize yield and the uniformity of several
bolometer parameters. The assembled FPUs have high yields, with one array as
high as 95% including defects from wiring and readout. We demonstrate high
uniformity in device parameters, finding the median saturation power for each
TES array to be ~3 pW at 300 mK with a less than 6% variation across each array
at one standard deviation. These focal planes will be deployed alongside the 95
and 150 GHz telescopes in the SPIDER-2 instrument, slated to fly from McMurdo
Station in Antarctica in December 2018.