Normalized to: Shaibonov, B.
[1]
oai:arXiv.org:1201.2122 [pdf] - 1092853
The Tunka-133 EAS Cherenkov light array: status of 2011
Berezhnev, S. F.;
Besson, D.;
Korobchenko, A. V.;
Budnev, N. M.;
Chiavassa, A.;
Chvalaev, O. A.;
Gress, O. A.;
Dyachok, A. N.;
Epimakhov, S. N.;
Haungs, A.;
Karpov, N. I.;
Kalmykov, N. N.;
Konstantinov, E. N.;
Korobchenko, A. V.;
Korosteleva, E. E.;
Kozhin, V. A.;
Kuzmichev, L. A.;
Lubsandorzhiev, B. K.;
Lubsandorzhiev, N. B.;
Mirgazov, R. R.;
Panasyuk, M. I.;
Pankov, L. V.;
Popova, E. G.;
Prosin, V. V.;
Ptuskin, V. S.;
Semeney, Yu. A.;
Shaibonov, B. A.;
Silaev, A. A.;
Silaev, A. A.;
Skurikhin, A. V.;
Snyder, J.;
Spiering, C.;
Schreoder, F. G.;
Stockham, M.;
Sveshnikova, L. G.;
Wischnewski, R.;
Yashin, I. V.;
Zagorodnikov, A. V.
Submitted: 2012-01-10
A new EAS Cherenkov light array, Tunka-133, with ~1 km^2 geometrical area has
been installed at the Tunka Valley (50 km from Lake Baikal) in 2009. The array
permits a detailed study of cosmic ray energy spectrum and mass composition in
the energy range 10^16 - 10^18 eV with a uniform method. We describe the array
construction, DAQ and methods of the array calibration.The method of energy
reconstruction and absolute calibration of measurements are discussed. The
analysis of spatial and time structure of EAS Cherenkov light allows to
estimate the depth of the EAS maximum X_max. The results on the all particles
energy spectrum and the mean depth of the EAS maximum X_max vs. primary energy
derived from the data of two winter seasons (2009 -- 2011), are presented.
Preliminary results of joint operation of the Cherenkov array with antennas for
detection of EAS radio signals are shown. Plans for future upgrades --
deployment of remote clusters, radioantennas and a scintillator detector
network and a prototype of the HiSCORE gamma-telescope -- are discussed.
[2]
oai:arXiv.org:1003.0089 [pdf] - 125812
The Tunka-133 EAS Chrenkov array - status, first results and plans
Budnev, N. M.;
Besson, D.;
Chvalaev, O. A.;
Gress, O. A.;
Kalmykov, N. N.;
Kochanov, A. A.;
Korobchenko, A. V.;
Korosteleva, E. E.;
Kozhin, V. A.;
Kuzmichev, L. A.;
Lubsandorzhiev, B. K.;
Mirgazov, R. R.;
Navarra, G.;
Panasyuk, M. I.;
Pankov, L. V.;
Prosin, V. V.;
Ptuskin, V. S.;
Semeney, Yu. A.;
Shaibonov, B. A.;
Skurikhin, A. V.;
Snyder, J.;
Spiering, C.;
Stockham, M.;
Wischnewski, R.;
Yashin, I. V.;
Zablotsky, A. V.;
Zagorodnikov, A. V.
Submitted: 2010-02-27
The new EAS Cherenkov array Tunka-133 with about 1 km**2 geometric acceptance
area is installed in the Tunka Valley (50 km from Lake Baikal). The array
willpermit a detailed study of cosmic ray energy spectrum and mass composition
in the energy range of 10**15 - 10**18 eV with uniform method. The array
consistsof 19 clusters, each composed of 7 optical detectors with 20 cm PMTs.
Since November 2008, the first 12 clusters are in operation, commissioning of
the whole array is planned for September 2009 (At the time of submission of
this paperto electronic arXiv(February 2010) the completed Tunka-133 array is
already taking data). We describe the array construction and DAQ, preliminary
results and plans for the future development: deployment of radio-antennas and
muon detectors network.
[3]
oai:arXiv.org:0804.0856 [pdf] - 1579281
Data acquisition system for the TUNKA-133 array
Budnev, N. M.;
Chvalaev, O. B.;
Gress, O. A.;
Kalmykov, N. N.;
Kozhin, V. A.;
Korosteleva, E. E.;
Kuzmichev, L. A.;
Lubsandorzhiev, B. K.;
Mirgazov, R. R.;
Navarra, G.;
Panasyuk, M. I.;
Pankov, L. V.;
Prosin, V. V.;
Ptuskin, V. S.;
Semeney, Y. A.;
Skurikhin, A. V.;
Shaibonov, B. A.;
Spiering, Ch.;
Wischnewski, R.;
Yashin, I. V.;
Zablotsky, A. Z.;
Zagorodnikov, A. V.
Submitted: 2008-04-05, last modified: 2008-04-14
The new EAS Cherenkov array TUNKA-133, with about 1 km**2 sensitive area, is
being installed in the Tunka Valley. The investigated energy range is
10**15-10**18 eV. It will consist of 133 optical detectors based on EMI9350
PMTs. Optical detectors are grouped into 19 clusters with 7 detectors each. The
detectors are connected to the cluster box with RG-58 cables. Every PMT signal
is digitized in the cluster box with 200 MHz FADC. The cluster boxes are
connected to the data acquisition center with a 1 Gb/s optical link. A detailed
description of the data acquisition system (DAQ) is presented.
[4]
oai:arXiv.org:0801.3037 [pdf] - 9194
Tunka-133 EAS Cherenkov Array: Status of 2007
Budnev, N. M.;
Chvalaev, O. V.;
Gress, O. A.;
Kalmykov, N. N.;
Kozhin, V. A.;
Korosteleva, E. E.;
Kuzmichev, L. A.;
Lubsandorzhiev, B. K.;
Mirgazov, R. R.;
Navarra, G.;
Panasyuk, M. I.;
Pankov, L. V.;
Prosin, V. V.;
Ptuskin, V. S.;
Semeney, Y. A.;
Skurikhin, A. V.;
Shaibonov, B. A.;
Spiering, Ch.;
Wieschnewski, R.;
Yashin, I. V.;
Zablotsky, A. V.;
Zagorodnikov, A. V.
Submitted: 2008-01-19
The new EAS Cherenkov array Tunka-133, with about 1 km**2 sensitive area, is
being installed in the Tunka Valley since the end of 2005. This array will
permit a detailed study of the cosmic ray energy spectrum and the mass
composition in the energy range of 10**15-10**18 eV with a unique method. The
array will consist of 19 clusters, each composed of 7 optical detectors. The
first cluster started operation in October 2006. We describe the data
acquisition system and present preliminary results from data taken with the
first cluster.
[5]
oai:arXiv.org:physics/0601157 [pdf] - 119143
Photoelectron backscattering in vacuum phototubes
Submitted: 2006-01-20
In this article we describe results of a photoelectron backscattering effect
in vacuum phototubes: classical photomultipliers (PMT) and hybrid phototubes
(PH). Late pulses occurring in PMTs are attributed to the photoelectron
backscattering and distinguished from pulses due to an anode glow effect. The
late pulses are measured in a number of PMTs and HPs with various photocathode
sizes covering 1-50 cm range and different types of the first dynode materials
and construction designs. It is shown that the late pulses are a generic
feature of all vacuum photodetectors - PMTs and PHs and they don't deteriorate
dramatically amplitude and timing responses of vacuum phototubes.