Normalized to: Shah, V.
[1]
oai:arXiv.org:1903.06303 [pdf] - 1894260
The Elusive Majority of Young Moving Groups. I. Young Binaries and
Lithium-Rich Stars in the Solar Neighborhood
Bowler, Brendan P.;
Hinkley, Sasha;
Ziegler, Carl;
Baranec, Christoph;
Gizis, John E.;
Law, Nicholas M.;
Liu, Michael C.;
Shah, Viyang S.;
Shkolnik, Evgenya L.;
Riaz, Basmah;
Riddle, Reed
Submitted: 2019-03-14
Young stars in the solar neighborhood serve as nearby probes of stellar
evolution and represent promising targets to directly image self-luminous giant
planets. We have carried out an all-sky search for late-type ($\approx$K7$-$M5)
stars within 100 pc selected primarily on the basis of activity indicators from
$GALEX$ and $ROSAT$. Approximately two thousand active and potentially young
stars are identified, over 600 of which we have followed up with low-resolution
optical spectroscopy and over 1000 with diffraction-limited imaging using
Robo-AO at the Palomar 1.5-m telescope. Strong lithium is present in 58 stars,
implying ages spanning $\approx$10$-$200 Myr. Most of these lithium-rich stars
are new or previously known members of young moving groups including TWA,
$\beta$ Pic, Tuc-Hor, Carina, Columba, Argus, AB Dor, Upper Centaurus Lupus,
and Lower Centaurus Crux; the rest appear to be young low-mass stars without
connections to established kinematic groups. Over 200 close binaries are
identified down to 0.2$''$ $-$ the vast majority of which are new $-$ and will
be valuable for dynamical mass measurements of young stars with continued orbit
monitoring in the future.
[2]
oai:arXiv.org:1607.06485 [pdf] - 1460965
Precision velocimetry planet hunting with PARAS: Current performance and
lessons to inform future extreme precision radial velocity instruments
Submitted: 2016-07-21
PARAS is a fiber-fed stabilized high-resolution cross-dispersed echelle
spectrograph, located on the 1.2 m telescope in Mt. Abu India. Designed for
exoplanet detection, PARAS is capable of single-shot spectral coverage of 3800
- 9600 A, and currently achieving radial velocity (RV) precisions approaching
~1 m/s over several months using simultaneous ThAr calibration. As such, it is
one of the few dedicated stabilized fiber-fed spectrographs on small (1-2 m)
telescopes that are able to fill an important niche in RV follow-up and stellar
characterization. The success of ground-based RV surveys is motivating the push
into extreme precisions, with goals of ~10 cm/s in the optical and <1 m/s in
the near-infrared (NIR). Lessons from existing instruments like PARAS are
invaluable in informing hardware design, providing pipeline prototypes, and
guiding scientific surveys. Here we present our current precision estimates of
PARAS based on observations of bright RV standard stars, and describe the
evolution of the data reduction and RV analysis pipeline as instrument
characterization progresses and we gather longer baselines of data. Secondly,
we discuss how our experience with PARAS is a critical component in the
development of future cutting edge instruments like (1) the Habitable Zone
Planet Finder (HPF), a NIR spectrograph optimized to look for planets around M
dwarfs, scheduled to be commissioned on the Hobby Eberly Telescope in 2017, and
(2) the NEID optical spectrograph, designed in response to the NN-EXPLORE call
for an extreme precision Doppler spectrometer (EPDS) for the WIYN telescope. In
anticipation of instruments like TESS and GAIA, the ground-based RV support
system is being reinforced. We emphasize that instruments like PARAS will play
an intrinsic role in providing both complementary follow-up and battlefront
experience for these next generation of precision velocimeters.
[3]
oai:arXiv.org:1312.5471 [pdf] - 1202371
The PRL Stabilized High Resolution Echelle Fiber-fed Spectrograph:
Instrument Description & First Radial Velocity Results
Chakraborty, Abhijit;
Mahadevan, Suvrath;
Roy, Arpita;
Dixit, Vaibhav;
Richardson, Eric Harvey;
Dongre, Varun;
Pathan, F. M.;
Chaturvedi, Priyanka;
Shah, Vishal;
Ubale, Girish P.;
Anandarao, B. G.
Submitted: 2013-12-19
We present spectrograph design details and initial radial velocity results
from the PRL optical fiber-fed high-resolution cross-dispersed echelle
spectrograph (PARAS), which has recently been commissioned at the Mt Abu 1.2 m
telescope, in India. Data obtained as part of the post-commissioning tests with
PARAS show velocity precision better than 2m/s over a period of several months
on bright RV standard stars. For observations of sigma-Dra we report 1.7m/s
precision for a period of seven months and 2.1m/s for HD 9407 over a period of
2 months. PARAS is capable of a single-shot spectral coverage of 3800A - 9500A
at a resolution of about 67,000. The RV results were obtained between 3800A and
6900A using simultaneous wavelength calibration with a Thorium-Argon (ThAr)
hollow cathode lamp. The spectrograph is maintained under stable conditions of
temperature with a precision of 0.01 - 0.02C (rms) at 25.55C, and enclosed in a
vacuum vessel at pressure of 0.1 +/-0.03 mbar. The blaze peak efficiency of the
spectrograph between 5000A and 6500A, including the detector, is 30%; and about
25% with the fiber transmission. The total efficiency, including spectrograph,
fiber transmission, focal ratio degradation (FRD), and telescope (with 81%
reflectivity) is about 7% in the same wavelength region on a clear night with
good seeing conditions.
[4]
oai:arXiv.org:1007.4280 [pdf] - 1033890
First Light results from PARAS: The PRL Echelle Spectrograph
Submitted: 2010-07-24
We present the first light commissioning results from the Physical Research
Laboratory (PRL) optical fiber-fed high resolution cross-dispersed Echelle
Spectrograph. It is capable of a single- shot spectral coverage of 3700A to
8600A at R ~ 63,000 and is under very stable conditions of temperature
(0.04{\deg}C at 23{\deg}C). In the very near future pressure control will also
be achieved by enclosing the entire spectrograph in a low-pressure vacuum
chamber (~0.01mbar). It is attached to a 1.2m telescope using two 50micron core
optical fibers (one for the star and another for simultaneous Th-Ar spectral
calibration). The 1.2m telescope is located at Mt. Abu, India, and we are
guaranteed about 80 to 100 nights a year for observations with the
spectrograph. The instrument will be ultimately used for radial-velocity
searches of exoplanets around 1000 dwarf stars, brighter than 10th magnitude,
for the next 5 years with a precision of 3 to 5m/s using the simultaneous Th-Ar
spectral lamp reference technique. The spectrograph has already achieved a
stability of 3.7m/s in short-term time scale and in the near future we expect
the stability to be at 1m/s once we install the spectrograph inside the vacuum
chamber.
[5]
oai:arXiv.org:astro-ph/0612356 [pdf] - 87694
The Fe-Line Feature In The X-Ray Spectrum of Solar Flares: First Results
From The SOXS Mission
Submitted: 2006-12-13
We present the first results from the "Low Energy Detector" payload of the
"Solar X-ray Spectrometer (SOXS)" mission, which was launched onboard the
GSAT-2 Indian spacecraft on 08 May 2003 by the GSLV-D2 rocket to study solar
flares. The SOXS Low Energy Detector (SLD) payload was designed, developed, and
fabricated by the Physical Research Laboratory (PRL) in collaboration with the
Space Application Centre (SAC), Ahmedabad and the ISRO Satellite Centre (ISAC),
Bangalore of Indian Space Research Organization (ISRO). The energy ranges of
the Si PIN and CZT detectors are 4 - 25 keV and 4 - 56 keV respectively. The Si
PIN provides sub-keV energy resolution while the CZT reveals ~1.7 keV energy
resolution throughout the energy range. The high sensitivity and sub-keV energy
resolution of the Si PIN detector allows measuring the intensity, peak energy,
and the equivalent width of the Fe-line complex at approximately 6.7 keV as a
function of time in all ten M-class flares studied in this investigation. The
peak energy (Ep) of the Fe-line feature varies between 6.4 and 6.7 keV with
increasing in temperature from 9 to 58 MK. We found that the equivalent width
(w) of the Fe-line feature increases exponentially with temperature up to 30 MK
and then increases very slowly up to 40 Mk. It remains between 3.5 and 4 keV in
the temperature range of 30 - 45 MK. We compare our measurements of w with
calculations made earlier by various investigators and propose that these
measurements may improve theoretical models. We interpret the variation of both
Ep and w with temperature as due to the changes in the ionization and
recombination conditions in the plasma during the flare interval and as a
consequence the contribution from different ionic emission lines also varies.