Normalized to: Seth, S.
[1]
oai:arXiv.org:1907.12509 [pdf] - 2100293
Velocity independent constraints on spin-dependent DM-nucleon
interactions from IceCube and PICO
IceCube Collaboration;
Aartsen, M. G.;
Ackermann, M.;
Adams, J.;
Aguilar, J. A.;
Ahlers, M.;
Ahrens, M.;
Alispach, C.;
Andeen, K.;
Anderson, T.;
Ansseau, I.;
Anton, G.;
Argüelles, C.;
Auffenberg, J.;
Axani, S.;
Backes, P.;
Bagherpour, H.;
Bai, X.;
V., A. Balagopal;
Barbano, A.;
Barwick, S. W.;
Bastian, B.;
Baum, V.;
Baur, S.;
Bay, R.;
Beatty, J. J.;
Becker, K. -H.;
Tjus, J. Becker;
BenZvi, S.;
Berley, D.;
Bernardini, E.;
Besson, D. Z.;
Binder, G.;
Bindig, D.;
Blaufuss, E.;
Blot, S.;
Bohm, C.;
Börner, M.;
Böser, S.;
Botner, O.;
Böttcher, J.;
Bourbeau, E.;
Bourbeau, J.;
Bradascio, F.;
Braun, J.;
Bron, S.;
Brostean-Kaiser, J.;
Burgman, A.;
Buscher, J.;
Busse, R. S.;
Carver, T.;
Chen, C.;
Cheung, E.;
Chirkin, D.;
Choi, S.;
Classen, L.;
Coleman, A.;
Collin, G. H.;
Conrad, J. M.;
Coppin, P.;
Correa, P.;
Cowen, D. F.;
Cross, R.;
Dave, P.;
De Clercq, C.;
DeLaunay, J. J.;
Dembinski, H.;
Deoskar, K.;
De Ridder, S.;
Desiati, P.;
de Vries, K. D.;
de Wasseige, G.;
de With, M.;
DeYoung, T.;
Diaz, A.;
Díaz-Vélez, J. C.;
Dujmovic, H.;
Dunkman, M.;
Dvorak, E.;
Eberhardt, B.;
Ehrhardt, T.;
Eller, P.;
Engel, R.;
Evenson, P. A.;
Fahey, S.;
Fazely, A. R.;
Felde, J.;
Filimonov, K.;
Finley, C.;
Franckowiak, A.;
Friedman, E.;
Fritz, A.;
Gaisser, T. K.;
Gallagher, J.;
Ganster, E.;
Garrappa, S.;
Gerhardt, L.;
Ghorbani, K.;
Glauch, T.;
Glüsenkamp, T.;
Goldschmidt, A.;
Gonzalez, J. G.;
Grant, D.;
Griffith, Z.;
Griswold, S.;
Günder, M.;
Gündüz, M.;
Haack, C.;
Hallgren, A.;
Halve, L.;
Halzen, F.;
Hanson, K.;
Haungs, A.;
Hebecker, D.;
Heereman, D.;
Heix, P.;
Helbing, K.;
Hellauer, R.;
Henningsen, F.;
Hickford, S.;
Hignight, J.;
Hill, G. C.;
Hoffman, K. D.;
Hoffmann, R.;
Hoinka, T.;
Hokanson-Fasig, B.;
Hoshina, K.;
Huang, F.;
Huber, M.;
Huber, T.;
Hultqvist, K.;
Hünnefeld, M.;
Hussain, R.;
In, S.;
Iovine, N.;
Ishihara, A.;
Japaridze, G. S.;
Jeong, M.;
Jero, K.;
Jones, B. J. P.;
Jonske, F.;
Joppe, R.;
Kang, D.;
Kang, W.;
Kappes, A.;
Kappesser, D.;
Karg, T.;
Karl, M.;
Karle, A.;
Katz, U.;
Kauer, M.;
Kelley, J. L.;
Kheirandish, A.;
Kim, J.;
Kintscher, T.;
Kiryluk, J.;
Kittler, T.;
Klein, S. R.;
Koirala, R.;
Kolanoski, H.;
Köpke, L.;
Kopper, C.;
Kopper, S.;
Koskinen, D. J.;
Kowalski, M.;
Krings, K.;
Krückl, G.;
Kulacz, N.;
Kurahashi, N.;
Kyriacou, A.;
Labare, M.;
Lanfranchi, J. L.;
Larson, M. J.;
Lauber, F.;
Lazar, J. P.;
Leonard, K.;
Leszczyńska, A.;
Leuermann, M.;
Liu, Q. R.;
Lohfink, E.;
Mariscal, C. J. Lozano;
Lu, L.;
Lucarelli, F.;
Lünemann, J.;
Luszczak, W.;
Lyu, Y.;
Ma, W. Y.;
Madsen, J.;
Maggi, G.;
Mahn, K. B. M.;
Makino, Y.;
Mallik, P.;
Mallot, K.;
Mancina, S.;
Mariş, I. C.;
Maruyama, R.;
Mase, K.;
Maunu, R.;
McNally, F.;
Meagher, K.;
Medici, M.;
Medina, A.;
Meier, M.;
Meighen-Berger, S.;
Menne, T.;
Merino, G.;
Meures, T.;
Micallef, J.;
Mockler, D.;
Momenté, G.;
Montaruli, T.;
Moore, R. W.;
Morse, R.;
Moulai, M.;
Muth, P.;
Nagai, R.;
Naumann, U.;
Neer, G.;
Niederhausen, H.;
Nowicki, S. C.;
Nygren, D. R.;
Pollmann, A. Obertacke;
Oehler, M.;
Olivas, A.;
O'Murchadha, A.;
O'Sullivan, E.;
Palczewski, T.;
Pandya, H.;
Pankova, D. V.;
Park, N.;
Peiffer, P.;
Heros, C. Pérez de los;
Philippen, S.;
Pieloth, D.;
Pinat, E.;
Pizzuto, A.;
Plum, M.;
Porcelli, A.;
Price, P. B.;
Przybylski, G. T.;
Raab, C.;
Raissi, A.;
Rameez, M.;
Rauch, L.;
Rawlins, K.;
Rea, I. C.;
Reimann, R.;
Relethford, B.;
Renschler, M.;
Renzi, G.;
Resconi, E.;
Rhode, W.;
Richman, M.;
Robertson, S.;
Rongen, M.;
Rott, C.;
Ruhe, T.;
Ryckbosch, D.;
Rysewyk, D.;
Safa, I.;
Herrera, S. E. Sanchez;
Sandrock, A.;
Sandroos, J.;
Santander, M.;
Sarkar, S.;
Sarkar, S.;
Satalecka, K.;
Schaufel, M.;
Schieler, H.;
Schlunder, P.;
Schmidt, T.;
Schneider, A.;
Schneider, J.;
Schröder, F. G.;
Schumacher, L.;
Sclafani, S.;
Seckel, D.;
Seunarine, S.;
Shefali, S.;
Silva, M.;
Snihur, R.;
Soedingrekso, J.;
Soldin, D.;
Song, M.;
Spiczak, G. M.;
Spiering, C.;
Stachurska, J.;
Stamatikos, M.;
Stanev, T.;
Stein, R.;
Steinmüller, P.;
Stettner, J.;
Steuer, A.;
Stezelberger, T.;
Stokstad, R. G.;
Stößl, A.;
Strotjohann, N. L.;
Stürwald, T.;
Stuttard, T.;
Sullivan, G. W.;
Taboada, I.;
Tenholt, F.;
Ter-Antonyan, S.;
Terliuk, A.;
Tilav, S.;
Tomankova, L.;
Tönnis, C.;
Toscano, S.;
Tosi, D.;
Trettin, A.;
Tselengidou, M.;
Tung, C. F.;
Turcati, A.;
Turcotte, R.;
Turley, C. F.;
Ty, B.;
Unger, E.;
Elorrieta, M. A. Unland;
Usner, M.;
Vandenbroucke, J.;
Van Driessche, W.;
van Eijk, D.;
van Eijndhoven, N.;
Vanheule, S.;
van Santen, J.;
Vraeghe, M.;
Walck, C.;
Wallace, A.;
Wallraff, M.;
Wandkowsky, N.;
Watson, T. B.;
Weaver, C.;
Weindl, A.;
Weiss, M. J.;
Weldert, J.;
Wendt, C.;
Werthebach, J.;
Whelan, B. J.;
Whitehorn, N.;
Wiebe, K.;
Wiebusch, C. H.;
Wille, L.;
Williams, D. R.;
Wills, L.;
Wolf, M.;
Wood, J.;
Wood, T. R.;
Woschnagg, K.;
Wrede, G.;
Xu, D. L.;
Xu, X. W.;
Xu, Y.;
Yanez, J. P.;
Yodh, G.;
Yoshida, S.;
Yuan, T.;
Collaboration, M. Zöcklein. PICO;
:;
Amole, C.;
Ardid, M.;
Arnquist, I. J.;
Asner, D. M.;
Baxter, D.;
Behnke, E.;
Bressler, M.;
Broerman, B.;
Cao, G.;
Chen, C. J.;
Chowdhury, U.;
Clark, K.;
Collar, J. I.;
Cooper, P. S.;
Crisler, M.;
Crowder, G.;
Cruz-Venegas, N. A.;
Dahl, C. E.;
Das, M.;
Fallows, S.;
Farine, J.;
Felis, I.;
Filgas, R.;
Girard, F.;
Giroux, G.;
Hall, J.;
Hardy, C.;
Harris, O.;
Hoppe, E. W.;
Jin, M.;
Klopfenstein, L.;
Krauss, C. B.;
Laurin, M.;
Lawson, I.;
Leblanc, A.;
Levine, I.;
Lippincott, W. H.;
Mamedov, F.;
Maurya, D.;
Mitra, P.;
Moore, C.;
Nania, T.;
Neilson, R.;
Noble, A. J.;
Oedekerk, P.;
Ortega, A.;
Piro, M. -C.;
Plante, A.;
Podviyanuk, R.;
Priya, S.;
Robinson, A. E.;
Sahoo, S.;
Scallon, O.;
Seth, S.;
Sonnenschein, A.;
Starinski, N.;
Štekl, I.;
Sullivan, T.;
Tardif, F.;
Vázquez-Jáuregui, E.;
Walkowski, N.;
Wichoski, U.;
Yan, Y.;
Zacek, V.;
Zhang, J.
Submitted: 2019-07-29, last modified: 2020-05-25
Adopting the Standard Halo Model (SHM) of an isotropic Maxwellian velocity
distribution for dark matter (DM) particles in the Galaxy, the most stringent
current constraints on their spin-dependent scattering cross-section with
nucleons come from the IceCube neutrino observatory and the PICO-60 C$_3$F$_8$
superheated bubble chamber experiments. The former is sensitive to high energy
neutrinos from the self-annihilation of DM particles captured in the Sun, while
the latter looks for nuclear recoil events from DM scattering off nucleons.
Although slower DM particles are more likely to be captured by the Sun, the
faster ones are more likely to be detected by PICO. Recent N-body simulations
suggest significant deviations from the SHM for the smooth halo component of
the DM, while observations hint at a dominant fraction of the local DM being in
substructures. We use the method of Ferrer et al. (2015) to exploit the
complementarity between the two approaches and derive conservative constraints
on DM-nucleon scattering. Our results constrain $\sigma_{\mathrm{SD}} \lesssim
3 \times 10^{-39} \mathrm{cm}^2$ (6 $ \times 10^{-38} \mathrm{cm}^2$) at
$\gtrsim 90\%$ C.L. for a DM particle of mass 1~TeV annihilating into $\tau^+
\tau^-$ ($b\bar{b}$) with a local density of $\rho_{\mathrm{DM}} = 0.3~\mathrm{
GeV/cm}^3$. The constraints scale inversely with $\rho_{\mathrm{DM}}$ and are
independent of the DM velocity distribution.
[2]
oai:arXiv.org:1905.04706 [pdf] - 2093082
Probing low-mass WIMP candidates of dark matter with tetrafluoroethane
superheated liquid detectors
Submitted: 2019-05-12, last modified: 2020-04-18
Probing low mass (sub-GeV -- few GeV) Weakly Interacting Massive Particle
(WIMP) candidates of dark matter through WIMP-induced nuclear recoils in direct
detection experiments requires use of detector materials consisting of low mass
target nuclei and low threshold energy. Here we explore the potential of
superheated liquid detectors (SLD) with a hydrogen containing liquid, namely,
tetrafluoroethane (C$_{2}$H$_{2}$F$_{4}$) (b.p.~$-26.3^\circ\,$C), as the
target material for probing low mass WIMPs. It is found that few-keV level
recoil energy thresholds possible for bubble nucleation by WIMP-induced
$^{12}$C and $^{19}$F recoils in C$_{2}$H$_{2}$F$_{4}$ SLDs operated at
atmospheric pressure and gamma-ray insensitive temperatures of $T\, \lesssim\,
35^\circ\,$C have the potential to allow WIMPs in the few-GeV mass range to be
probed at a WIMP-nucleon spin-independent cross section sensitivity levels (90%
C.L.) better than $4.6\times 10^{-5}\,$pb at WIMP masses down to $\sim$ 4 GeV
with a total exposure of $\sim$ 1000 kg.day, provided that the ``thermodynamic
efficiency" $\eta_{\rm T}$ that determines the bubble nucleation thresholds for
the recoiling nuclei in C$_{2}$H$_{2}$F$_{4}$ is $\sim$ 50% or higher.
Sensitivity to sub-GeV WIMP masses generally requires the detector to be
sensitive to the WIMP-induced $^1$H recoils, which in turn requires the
detector to be operated at temperatures $T\gtrsim 50^\circ\,$C and $\eta_{\rm
T}$ close to 100%. At such relatively high temperatures (at atmospheric
pressure), however, the detector would be sensitive to background gamma rays.
[3]
oai:arXiv.org:1905.12522 [pdf] - 1995410
Data-Driven Modeling of Electron Recoil Nucleation in PICO C$_3$F$_8$
Bubble Chambers
Amole, C.;
Ardid, M.;
Arnquist, I. J.;
Asner, D. M.;
Baxter, D.;
Behnke, E.;
Bressler, M.;
Broerman, B.;
Cao, G.;
Chen, C. J.;
Chen, S.;
Chowdhury, U.;
Clark, K.;
Collar, J. I.;
Cooper, P. S.;
Coutu, C. B.;
Cowles, C.;
Crisler, M.;
Crowder, G.;
Cruz-Venegas, N. A.;
Dahl, C. E.;
Das, M.;
Fallows, S.;
Farine, J.;
Filgas, R.;
Fuentes, J.;
Girard, F.;
Giroux, G.;
Hackett, B.;
Hagen, A.;
Hall, J.;
Hardy, C.;
Harris, O.;
Hillier, T.;
Hoppe, E. W.;
Jackson, C. M.;
Jin, M.;
Klopfenstein, L.;
Kozynets, T.;
Krauss, C. B.;
Laurin, M.;
Lawson, I.;
Leblanc, A.;
Levine, I.;
Licciardi, C.;
Lippincott, W. H.;
Loer, B.;
Mamedov, F.;
Mitra, P.;
Moore, C.;
Nania, T.;
Neilson, R.;
Noble, A. J.;
Oedekerk, P.;
Ortega, A.;
Pal, S.;
Piro, M. -C.;
Plante, A.;
Priya, S.;
Robinson, A. E.;
Sahoo, S.;
Scallon, O.;
Seth, S.;
Sonnenschein, A.;
Starinski, N.;
Štekl, I.;
Sullivan, T.;
Tardif, F.;
Tiwari, D.;
Vázquez-Jáuregui, E.;
Wagner, J. M.;
Walkowski, N.;
Weima, E.;
Wichoski, U.;
Wierman, K.;
Woodley, W.;
Yan, Y.;
Zacek, V.;
Zhang, J.
Submitted: 2019-05-29, last modified: 2019-11-06
The primary advantage of moderately superheated bubble chamber detectors is
their simultaneous sensitivity to nuclear recoils from WIMP dark matter and
insensitivity to electron recoil backgrounds. A comprehensive analysis of PICO
gamma calibration data demonstrates for the first time that electron recoils in
C$_3$F$_8$ scale in accordance with a new nucleation mechanism, rather than one
driven by a hot-spike as previously supposed. Using this semi-empirical model,
bubble chamber nucleation thresholds may be tuned to be sensitive to lower
energy nuclear recoils while maintaining excellent electron recoil rejection.
The PICO-40L detector will exploit this model to achieve thermodynamic
thresholds as low as 2.8 keV while being dominated by single-scatter events
from coherent elastic neutrino-nucleus scattering of solar neutrinos. In one
year of operation, PICO-40L can improve existing leading limits from PICO on
spin-dependent WIMP-proton coupling by nearly an order of magnitude for WIMP
masses greater than 3 GeV c$^{-2}$ and will have the ability to surpass all
existing non-xenon bounds on spin-independent WIMP-nucleon coupling for WIMP
masses from 3 to 40 GeV c$^{-2}$.
[4]
oai:arXiv.org:1902.04031 [pdf] - 1916812
Dark Matter Search Results from the Complete Exposure of the PICO-60
C$_3$F$_8$ Bubble Chamber
Amole, C.;
Ardid, M.;
Arnquist, I. J.;
Asner, D. M.;
Baxter, D.;
Behnke, E.;
Bressler, M.;
Broerman, B.;
Cao, G.;
Chen, C. J.;
Chowdhury, U.;
Clark, K.;
Collar, J. I.;
Cooper, P. S.;
Coutu, C. B.;
Cowles, C.;
Crisler, M.;
Crowder, G.;
Cruz-Venegas, N. A.;
Dahl, C. E.;
Das, M.;
Fallows, S.;
Farine, J.;
Felis, I.;
Filgas, R.;
Girard, F.;
Giroux, G.;
Hall, J.;
Hardy, C.;
Harris, O.;
Hillier, T.;
Hoppe, E. W.;
Jackson, C. M.;
Jin, M.;
Klopfenstein, L.;
Krauss, C. B.;
Laurin, M.;
Lawson, I.;
Leblanc, A.;
Levine, I.;
Licciardi, C.;
Lippincott, W. H.;
Loer, B.;
Mamedov, F.;
Mitra, P.;
Moore, C.;
Nania, T.;
Neilson, R.;
Noble, A. J.;
Oedekerk, P.;
Ortega, A.;
Piro, M. -C.;
Plante, A.;
Podviyanuk, R.;
Priya, S.;
Robinson, A. E.;
Sahoo, S.;
Scallon, O.;
Seth, S.;
Sonnenschein, A.;
Starinski, N.;
Štekl, I.;
Sullivan, T.;
Tardif, F.;
Vázquez-Jáuregui, E.;
Walkowski, N.;
Weima, E.;
Wichoski, U.;
Wierman, K.;
Yan, Y.;
Zacek, V.;
Zhang, J.
Submitted: 2019-02-11
Final results are reported from operation of the PICO-60 C$_3$F$_8$ dark
matter detector, a bubble chamber filled with 52 kg of C$_3$F$_8$ located in
the SNOLAB underground laboratory. The chamber was operated at thermodynamic
thresholds as low as 1.2 keV without loss of stability. A new blind 1404-kg-day
exposure at 2.45 keV threshold was acquired with approximately the same
expected total background rate as the previous 1167-kg-day exposure at 3.3 keV.
This increased exposure is enabled in part by a new optical tracking analysis
to better identify events near detector walls, permitting a larger fiducial
volume. These results set the most stringent direct-detection constraint to
date on the WIMP-proton spin-dependent cross section at 2.5 $\times$ 10$^{-41}$
cm$^2$ for a 25 GeV WIMP, and improve on previous PICO results for 3-5 GeV
WIMPs by an order of magnitude.
[5]
oai:arXiv.org:1702.07666 [pdf] - 1581621
Dark Matter Search Results from the PICO-60 C$_3$F$_8$ Bubble Chamber
Amole, C.;
Ardid, M.;
Arnquist, I. J.;
Asner, D. M.;
Baxter, D.;
Behnke, E.;
Bhattacharjee, P.;
Borsodi, H.;
Bou-Cabo, M.;
Campion, P.;
Cao, G.;
Chen, C. J.;
Chowdhury, U.;
Clark, K.;
Collar, J. I.;
Cooper, P. S.;
Crisler, M.;
Crowder, G.;
Dahl, C. E.;
Das, M.;
Fallows, S.;
Farine, J.;
Felis, I.;
Filgas, R.;
Girard, F.;
Giroux, G.;
Hall, J.;
Harris, O.;
Hoppe, E. W.;
Jin, M.;
Krauss, C. B.;
Laurin, M.;
Lawson, I.;
Leblanc, A.;
Levine, I.;
Lippincott, W. H.;
Mamedov, F.;
Maurya, D.;
Mitra, P.;
Nania, T.;
Neilson, R.;
Noble, A. J.;
Olson, S.;
Ortega, A.;
Plante, A.;
Podviyanuk, R.;
Priya, S.;
Robinson, A. E.;
Roeder, A.;
Rucinski, R.;
Scallon, O.;
Seth, S.;
Sonnenschein, A.;
Starinski, N.;
Štekl, I.;
Tardif, F.;
Vázquez-Jáuregui, E.;
Wells, J.;
Wichoski, U.;
Yan, Y.;
Zacek, V.;
Zhang, J.
Submitted: 2017-02-24, last modified: 2017-08-02
New results are reported from the operation of the PICO-60 dark matter
detector, a bubble chamber filled with 52 kg of C$_3$F$_8$ located in the
SNOLAB underground laboratory. As in previous PICO bubble chambers, PICO-60
C$_3$F$_8$ exhibits excellent electron recoil and alpha decay rejection, and
the observed multiple-scattering neutron rate indicates a single-scatter
neutron background of less than 1 event per month. A blind analysis of an
efficiency-corrected 1167-kg-day exposure at a 3.3-keV thermodynamic threshold
reveals no single-scattering nuclear recoil candidates, consistent with the
predicted background. These results set the most stringent direct-detection
constraint to date on the WIMP-proton spin-dependent cross section at 3.4
$\times$ 10$^{-41}$ cm$^2$ for a 30-GeV$\thinspace$c$^{-2}$ WIMP, more than one
order of magnitude improvement from previous PICO results.
[6]
oai:arXiv.org:1611.01499 [pdf] - 1551948
Final Results of the PICASSO Dark Matter Search Experiment
Behnke, E.;
Besnier, M.;
Bhattacharjee, P.;
Dai, X.;
Das, M.;
Davour, A.;
Debris, F.;
Dhungana, N.;
Farine, J.;
Fines-Neuschild, M.;
Gagnebin, S.;
Giroux, G.;
Grace, E.;
Jackson, C. M.;
Kamaha, A.;
Krauss, C. B.;
Lafrenière, M.;
Laurin, M.;
Lawson, I.;
Lessard, L.;
Levine, I.;
Marlisov, D.;
Martin, J. -P.;
Mitra, P.;
Noble, A. J.;
Plante, A.;
Podviyanuk, R.;
Pospisil, S.;
Scallon, O.;
Seth, S.;
Starinski, N.;
Stekl, I.;
Wichoski, U.;
Zacek, V.
Submitted: 2016-11-04, last modified: 2017-03-23
The PICASSO dark matter search experiment operated an array of 32 superheated
droplet detectors containing 3.0 kg of C$_{4}$F$_{10}$ and collected an
exposure of 231.4 kgd at SNOLAB between March 2012 and January 2014. We report
on the final results of this experiment which includes for the first time the
complete data set and improved analysis techniques including \mbox{acoustic}
localization to allow fiducialization and removal of higher activity regions
within the detectors. No signal consistent with dark matter was observed. We
set limits for spin-dependent interactions on protons of
$\sigma_p^{SD}$~=~1.32~$\times$~10$^{-2}$~pb (90\%~C.L.) at a WIMP mass of 20
GeV/c$^{2}$. In the spin-independent sector we exclude cross sections larger
than $\sigma_p^{SI}$~=~4.86~$\times$~10$^{-5 }$~pb~(90\% C.L.) in the region
around 7 GeV/c$^{2}$. The pioneering efforts of the PICASSO experiment have
paved the way forward for a next generation detector incorporating much of this
technology and experience into larger mass bubble chambers.
[7]
oai:arXiv.org:1510.07754 [pdf] - 1382070
Dark Matter Search Results from the PICO-60 CF$_3$I Bubble Chamber
Amole, C.;
Ardid, M.;
Asner, D. M.;
Baxter, D.;
Behnke, E.;
Bhattacharjee, P.;
Borsodi, H.;
Bou-Cabo, M.;
Brice, S. J.;
Broemmelsiek, D.;
Clark, K.;
Collar, J. I.;
Cooper, P. S.;
Crisler, M.;
Dahl, C. E.;
Daley, S.;
Das, M.;
Debris, F.;
Dhungana, N.;
Farine, J.;
Felis, I.;
Filgas, R.;
Girard, F.;
Giroux, G.;
Grandison, A.;
Hai, M.;
Hall, J.;
Harris, O.;
Jin, M.;
Krauss, C. B.;
Fallows, S.;
Lafrenière, M.;
Laurin, M.;
Lawson, I.;
Levine, I.;
Lippincott, W. H.;
Mann, E.;
Maurya, D.;
Mitra, P.;
Neilson, R.;
Noble, A. J.;
Plante, A.;
Podviianiuk, R. B.;
Priya, S.;
Ramberg, E.;
Robinson, A. E.;
Rucinski, R.;
Ruschman, M.;
Scallon, O.;
Seth, S.;
Simon, P.;
Sonnenschein, A.;
Štekl, I.;
Vàzquez-Jàuregui, E.;
Wells, J.;
Wichoski, U.;
Zacek, V.;
Zhang, J.;
Shkrob, I. A.
Submitted: 2015-10-26, last modified: 2016-03-03
New data are reported from the operation of the PICO-60 dark matter detector,
a bubble chamber filled with 36.8 kg of CF$_3$I and located in the SNOLAB
underground laboratory. PICO-60 is the largest bubble chamber to search for
dark matter to date. With an analyzed exposure of 92.8 livedays, PICO-60
exhibits the same excellent background rejection observed in smaller bubble
chambers. Alpha decays in PICO-60 exhibit frequency-dependent acoustic
calorimetry, similar but not identical to that reported recently in a
C$_3$F$_8$ bubble chamber. PICO-60 also observes a large population of unknown
background events, exhibiting acoustic, spatial, and timing behaviors
inconsistent with those expected from a dark matter signal. These behaviors
allow for analysis cuts to remove all background events while retaining
$48.2\%$ of the exposure. Stringent limits on weakly interacting massive
particles interacting via spin-dependent proton and spin-independent processes
are set, and most interpretations of the DAMA/LIBRA modulation signal as dark
matter interacting with iodine nuclei are ruled out.
[8]
oai:arXiv.org:1503.00008 [pdf] - 1238863
Dark Matter Search Results from the PICO-2L C$_3$F$_8$ Bubble Chamber
Amole, C.;
Ardid, M.;
Asner, D. M.;
Baxter, D.;
Behnke, E.;
Bhattacharjee, P.;
Borsodi, H.;
Bou-Cabo, M.;
Brice, S. J.;
Broemmelsiek, D.;
Clark, K.;
Collar, J. I.;
Cooper, P. S.;
Crisler, M.;
Dahl, C. E.;
Daley, S.;
Das, M.;
Debris, F.;
Dhungana, N.;
Farine, J.;
Felis, I.;
Filgas, R.;
Fines-Neuschild, M.;
Girard, F.;
Giroux, G.;
Hai, M.;
Hall, J.;
Harris, O.;
Jackson, C. M.;
Jin, M.;
Krauss, C. B.;
Lafrenière, M.;
Laurin, M.;
Lawson, I.;
Levine, I.;
Lippincott, W. H.;
Mann, E.;
Martin, J. P.;
Maurya, D.;
Mitra, P.;
Neilson, R.;
Noble, A. J.;
Plante, A.;
Podviianiuk, R. B.;
Priya, S.;
Robinson, A. E.;
Ruschman, M.;
Scallon, O.;
Seth, S.;
Sonnenschein, A.;
Starinski, N.;
Štekl, I.;
Vàzquez-Jaùregui, E.;
Wells, J.;
Wichoski, U.;
Zacek, V.;
Zhang, J.
Submitted: 2015-02-27, last modified: 2015-06-29
New data are reported from the operation of a 2-liter C$_3$F$_8$ bubble
chamber in the 2100 meter deep SNOLAB underground laboratory, with a total
exposure of 211.5 kg-days at four different recoil energy thresholds ranging
from 3.2 keV to 8.1 keV. These data show that C3F8 provides excellent electron
recoil and alpha rejection capabilities at very low thresholds, including the
first observation of a dependence of acoustic signal on alpha energy. Twelve
single nuclear recoil event candidates were observed during the run. The
candidate events exhibit timing characteristics that are not consistent with
the hypothesis of a uniform time distribution, and no evidence for a dark
matter signal is claimed. These data provide the most sensitive direct
detection constraints on WIMP-proton spin-dependent scattering to date, with
significant sensitivity at low WIMP masses for spin-independent WIMP-nucleon
scattering.
[9]
oai:arXiv.org:1210.3132 [pdf] - 1579432
Searching for universal behaviour in superheated droplet detector with
effective recoil nuclei
Submitted: 2012-10-11
Energy calibration of superheated droplet detector is discussed in terms of
the effective recoil nucleus threshold energy and the reduced superheat. This
provides a universal energy calibration curve valid for different liquids used
in this type of detector. Two widely used liquids, R114 and C4F10, one for
neutron detection and the other for WIMPs dark matter search experiment, have
been compared. Liquid having recoil nuclei with larger values of LET provides
better neutron and gamma discrimination. Gamma response of C4F10 has also been
studied and the results are discussed. Behaviour of nucleation parameter with
the effective recoil nucleus threshold energy and the reduced superheat have
been explored.