Normalized to: Serpell, E.
[1]
oai:arXiv.org:1608.00045 [pdf] - 1460034
Gaia: focus, straylight and basic angle
Mora, A.;
Biermann, M.;
Bombrun, A.;
Boyadian, J.;
Chassat, F.;
Corberand, P.;
Davidson, M.;
Doyle, D.;
Escolar, D.;
Gielesen, W. L. M.;
Guilpain, T.;
Hernandez, J.;
Kirschner, V.;
Klioner, S. A.;
Koeck, C.;
Laine, B.;
Lindegren, L.;
Serpell, E.;
Tatry, P.;
Thoral, P
Submitted: 2016-07-29, last modified: 2016-08-21
The Gaia all-sky astrometric survey is challenged by several issues affecting
the spacecraft stability. Amongst them, we find the focus evolution, straylight
and basic angle variations
Contrary to pre-launch expectations, the image quality is continuously
evolving, during commissioning and the nominal mission. Payload
decontaminations and wavefront sensor assisted refocuses have been carried out
to recover optimum performance. Straylight and basic angle variations several
orders of magnitude greater than foreseen were found and studied during
commissioning by the Gaia scientists (payload experts). Building on their
investigations, an ESA-Airbus DS working group was established during the early
nominal mission and worked on a detailed root cause analysis. In parallel, Gaia
scientists have also continued analysing the data, most notably comparing the
BAM signal to global astrometric solutions, with remarkable agreement.
In this contribution, a status review of these issues will be provided, with
emphasis on the mitigation schemes and the lessons learned for future space
missions where extreme stability is a key requirement.
[2]
oai:arXiv.org:1503.02614 [pdf] - 1579612
The Gaia Basic angle: measurement and variations
Submitted: 2015-03-09
The ESA Gaia mission uses two telescopes to create the most ambitious survey
of the Galaxy. The angle between them must be known with exquisite precision
and accuracy. An interferometer: the Basic Angle Monitoring system measures its
variations. High quality data have been retrieved and analysed for more than a
year. A summary of the in-orbit performance and some early results are
presented
[3]
oai:arXiv.org:1407.3729 [pdf] - 1215653
Gaia on-board metrology: basic angle and best focus
Mora, A.;
Biermann, M.;
Brown, A. G. A.;
Busonero, D.;
Carminati, L.;
Carrasco, J. M.;
Chassat, F.;
Erdmann, M.;
Gielesen, W. L. M.;
Jordi, C.;
Katz, D.;
Kohley, R.;
Lindegren, L.;
Loeffler, W.;
Marchal, O.;
Panuzzo, P.;
Seabroke, G.;
Sahlmann, J.;
Serpell, E.;
Serraller, I.;
van Leeuwen, F.;
van Reeven, W.;
Dool, T. C. van den;
Vosteen, L. L. A.
Submitted: 2014-07-14
The Gaia payload ensures maximum passive stability using a single material,
SiC, for most of its elements. Dedicated metrology instruments are, however,
required to carry out two functions: monitoring the basic angle and refocusing
the telescope. Two interferometers fed by the same laser are used to measure
the basic angle changes at the level of $\mu$as (prad, micropixel), which is
the highest level ever achieved in space. Two Shack-Hartmann wavefront sensors,
combined with an ad-hoc analysis of the scientific data are used to define and
reach the overall best-focus. In this contribution, the systems, data analysis,
procedures and performance achieved during commissioning are presented
[4]
oai:arXiv.org:astro-ph/0203207 [pdf] - 48228
Timing with the EPIC pn Camera of XMM-Newton
Submitted: 2002-03-13
The EPIC pn CCD camera on board of XMM-Newton is designed to perform high
throughput imaging and spectroscopy as well as high resolution timing
observations in the energy range of 0.1-15 keV. A temporal resolution of
milliseconds or microseconds, depending on the instrument mode and detector, is
outstanding for CCD based X-ray cameras. In order to calibrate the different
observing modes of the EPIC pn CCD, XMM-Newton observations of the pulsars PSR
B1509-58, PSR B0540-69 and the Crab were performed during the calibration and
performance verification phase. To determine the accuracy of the on board clock
against Coordinated Universal Time (UTC), PSR B1509-58 was observed
simultaneously with XMM-Newton and RXTE in addition. The paper summarizes the
current status of the clock calibration.