Normalized to: Sergiampietri, F.
[1]
oai:arXiv.org:1712.01932 [pdf] - 1799803
Backgrounds and pulse shape discrimination in the ArDM liquid argon TPC
ArDM Collaboration;
Calvo, J.;
Cantini, C.;
Crivelli, P.;
Daniel, M.;
Di Luise, S.;
Gendotti, A.;
Horikawa, S.;
Molina-Bueno, L.;
Montes, B.;
Mu, W.;
Murphy, S.;
Natterer, G.;
Nguyen, K.;
Periale, L.;
Quan, Y.;
Radics, B.;
Regenfus, C.;
Romero, L.;
Rubbia, A.;
Santorelli, R.;
Sergiampietri, F.;
Viant, T.;
Wu, S.
Submitted: 2017-12-02
The ArDM experiment completed a single-phase commissioning run in 2015 with
an active liquid argon target of nearly one tonne in mass. The analysis of the
data and comparison to simulations allowed for a test of the crucial detector
properties and confirmed the low background performance of the setup. The
statistical rejection power for electron recoil events using the pulse shape
discrimination method was estimated using data from a Cf-252 neutron
calibration source. Electron and nuclear recoil band profiles were found to be
well described by Gaussian distributions. Employing such a model we derive
values for the electron recoil statistical rejection power of more than 10$^8$
in the tonne-scale liquid argon target for events with more than 50 detected
photons at a 50% acceptance for nuclear recoils. The Rn-222 emanation rate of
the ArDM cryostat at room temperature was found to be 65.6$\pm$0.4 $\mu$Hz/l,
and the Ar-39 specific activity from the employed atmospheric argon to be
0.95$\pm$0.05 Bq/kg. The cosmic muon flux at the Canfranc underground site was
determined to be between 2 and 3.5$\times 10^{-3}m^{2}s^{-1}$ . These results
pave the way for the next physics run of ArDM in the double-phase operational
mode.
[2]
oai:arXiv.org:1612.06375 [pdf] - 1551971
The ArDM Liquid Argon Time Projection Chamber at the Canfranc
Underground Laboratory: a ton-scale detector for Dark Matter Searches
ArDM Collaboration;
Calvo, J.;
Cantini, C.;
Crivelli, P.;
Daniel, M.;
DiLuise, S.;
Gendotti, A.;
Horikawa, S.;
Montes, B.;
Mu, W.;
Murphy, S.;
Natterer, G.;
Ngyuen, K.;
Periale, L.;
Quan, Y.;
Radics, B.;
Regenfus, C.;
Romero, L.;
Rubbia, A.;
Santorelli, R.;
Sergiampietri, F.;
Viant, T.;
Wu, S.
Submitted: 2016-12-19
The Argon Dark Matter (ArDM) experiment consists of a liquid argon (LAr) time
projection chamber (TPC) sensitive to nuclear recoils resulting from scattering
of hypothetical Weakly Interacting Massive Particles (WIMPs) on argon targets.
With an active target of 850 kg, ArDM represents an important milestone in the
quest for Dark Matter with LAr. We present the experimental apparatus currently
installed underground at the Laboratorio Subterraneo de Canfranc (LSC), Spain.
We show first data recorded during a single-phase commissioning run in 2015
(ArDM Run I), which overall confirm the good and stable performance of the
ton-scale LAr detector.
[3]
oai:arXiv.org:1611.02481 [pdf] - 1510448
Measurement of the attenuation length of argon scintillation light in
the ArDM LAr TPC
ArDM Collaboration;
Calvo, J.;
Cantini, C.;
Crivelli, P.;
Daniel, M.;
DiLuise, S.;
Gendotti, A.;
Horikawa, S.;
Molina-Bueno, L.;
Montes, B.;
Mu, W.;
Murphy, S.;
Natterer, G.;
Ngyuen, K.;
Periale, L.;
Quan, Y.;
Radics, B.;
Regenfus, C.;
Romero, L.;
Rubbia, A.;
Santorelli, R.;
Sergiampietri, F.;
Viant, T.;
Wu, S.
Submitted: 2016-11-08
We report on a measurement of the attenuation length for the scintillation
light in the tonne size liquid argon target of the ArDM dark matter experiment.
The data was recorded in the first underground operation of the experiment in
single-phase operational mode. The results were achieved by comparing the light
yield spectra from 39-Ar and 83m-Kr to a description of the ArDM setup with a
model of full light ray tracing. A relatively low value close to 0.5 m was
found for the attenuation length of the liquid argon bulk to its own
scintillation light. We interpret this result as a presence of optically active
impurities in the liquid argon which are not filtered by the installed
purification systems. We also present analyses of the argon gas employed for
the filling and discuss cross sections in the vacuum ultraviolet of various
molecules in respect to purity requirements in the context of large liquid
argon installations.
[4]
oai:arXiv.org:1505.02443 [pdf] - 996764
Status of ArDM-1t: First observations from operation with a full
ton-scale liquid argon target
ArDM Collaboration;
Calvo, J.;
Cantini, C.;
Daniel, M.;
Degunda, U.;
Di Luise, S.;
Epprecht, L.;
Gendotti, A.;
Horikawa, S.;
Knecht, L.;
Montes, B.;
Mu, W.;
Munoz, M.;
Murphy, S.;
Natterer, G.;
Nguyen, K.;
Nikolics, K.;
Periale, L.;
Regenfus, C.;
Romero, L.;
Rubbia, A.;
Santorelli, R.;
Sergiampietri, F.;
Sgalaberna, D.;
Viant, T.;
Wu, S.
Submitted: 2015-05-10
ArDM-1t is the first operating ton-scale liquid argon detector for direct
search of Dark Matter particles. Developed at CERN as Recognized Experiment
RE18, the experiment has been approved in 2010 to be installed in the Spanish
underground site LSC (Laboratorio Subterraneo de Canfranc). Under the label of
LSC EXP-08-2010 the ArDM detector underwent an intensive period of technical
completion and safety approval until the recent filling of the target vessel
with almost 2 ton of liquid argon. This report describes the experimental
achievements during commissioning of ArDM and the transition into a stage of
first physics data taking in single phase operational mode. We present
preliminary observations from this run. A first indication for the background
discrimination power of LAr detectors at the ton-scale is shown. We present an
outlook for completing the detector with the electric drift field and upgrade
of the scintillation light readout system with novel detector modules based on
SiPMs in order to improve the light yield.
[5]
oai:arXiv.org:0705.2117 [pdf] - 1279
R & D for Future Zeplin
Bisset, R.;
Carson, M. J.;
Chagani, H.;
Cline, D. B.;
Daw, E. J.;
Ferbel, T.;
Gao, J.;
Gao, Y. S.;
Kudryavtsev, V. A.;
Lightfoot, P. K.;
Majewski, P.;
Maxin, J.;
Miller, J.;
Ooi, W. C.;
Robinson, M.;
Salinas, G.;
Schroeder, U.;
Seifert, J.;
Sergiampietri, F.;
Skulski, W.;
Smith, P. F.;
Spooner, N. J. C.;
Toke, J.;
Wang, H.;
White, J. T.;
Wolfs, F.;
Yang, X.
Submitted: 2007-05-15
We propose a new concept for a very low background multi-ton liquid xenon
Dark Matter experiment. The detector consists of two concentric spheres and a
charge readout device in the centre. Xenon between the two spheres forms a
self-shield and veto device. The inner surface of the central sphere is coated
with CsI to form an internal photocathode with minimum of 2\pi coverage for any
event in the active volume. Photoelectrons from the CsI photocathode drift
toward the charge readout micro-structure in the centre of the detector. Both
scintillation and ionisation are measured simultaneously for background
rejection and 3-D event mapping. In addition to external shielding, the low
background is achieved by eliminating PMTs and by using low radioactivity pure
materials throughout the detector. We present detailed calculations of the
charge readout system and design details. The detector is expected to probe the
full SUSY parameter space.
[6]
oai:arXiv.org:astro-ph/0701858 [pdf] - 88987
First limits on WIMP nuclear recoil signals in ZEPLIN-II: a two phase
xenon detector for dark matter detection
Alner, G. J.;
Araujo, H. M.;
Bewick, A.;
Bungau, C.;
Camanzi, B.;
Carson, M. J.;
Cashmore, R. J.;
Chagani, H.;
Chepel, V.;
Cline, D.;
Davidge, D.;
Davies, J. C.;
Daw, E.;
Dawson, J.;
Durkin, T.;
Edwards, B.;
Gamble, T.;
Gao, J.;
Ghag, C.;
Howard, A. S.;
Jones, W. G.;
Joshi, M.;
Korolkova, E. V.;
Kudryavtsev, V. A.;
Lawson, T.;
Lebedenko, V. N.;
Lewin, J. D.;
Lightfoot, P.;
Lindote, A.;
Liubarsky, I.;
Lopes, M. I.;
Luscher, R.;
Majewski, P.;
Mavrokoridis, K;
McMillan, J. E.;
Morgan, B.;
Muna, D.;
Murphy, A. St. J.;
Neves, F.;
Nicklin, G. G.;
Ooi, W.;
Paling, S. M.;
da Cunha, J. Pinto;
Plank, S. J. S.;
Preece, R. M.;
Quenby, J. J.;
Robinson, M.;
Sergiampietri, F.;
Silva, C.;
Solovov, V. N.;
Smith, N. J. T.;
Smith, P. F.;
Spooner, N. J. C.;
Sumner, T. J.;
Thorne, C.;
Tovey, D. R.;
Tziaferi, E.;
Walker, R. J.;
Wang, H.;
White, J.;
Wolfs, F. L. H.
Submitted: 2007-01-30, last modified: 2007-01-31
Results are presented from the first underground data run of ZEPLIN-II, a 31
kg two phase xenon detector developed to observe nuclear recoils from
hypothetical weakly interacting massive dark matter particles. Discrimination
between nuclear recoils and background electron recoils is afforded by
recording both the scintillation and ionisation signals generated within the
liquid xenon, with the ratio of these signals being different for the two
classes of event. This ratio is calibrated for different incident species using
an AmBe neutron source and Co-60 gamma-ray sources. From our first 31 live days
of running ZEPLIN-II, the total exposure following the application of fiducial
and stability cuts was 225 kgxdays. A background population of radon progeny
events was observed in this run, arising from radon emission in the gas
purification getters, due to radon daughter ion decays on the surfaces of the
walls of the chamber. An acceptance window, defined by the neutron calibration
data, of 50% nuclear recoil acceptance between 5 keVee and 20 keVee, had an
observed count of 29 events, with a summed expectation of 28.6+/-4.3 gamma-ray
and radon progeny induced background events. These figures provide a 90% c.l.
upper limit to the number of nuclear recoils of 10.4 events in this acceptance
window, which converts to a WIMP-nucleon spin-independent cross-section with a
minimum of 6.6x10^-7 pb following the inclusion of an energy dependent,
calibrated, efficiency. A second run is currently underway in which the radon
progeny will be eliminated, thereby removing the background population, with a
projected sensitivity of 2x10^-7 pb for similar exposures as the first run.
[7]
oai:arXiv.org:astro-ph/0604548 [pdf] - 81617
LANNDD - A line of liquid argon TPC detectors scalable in mass from 200
Tons to 100 Ktons
Submitted: 2006-04-26
A scalable line of liquid argon TPC detectors is described, based on a three
dimensional cubic frame array immersed on a common liquid argon volume. The
paper describes general lines, main construction criteria, crucial points,
parameters and required preliminary R&D activities for the construction of
detectors with active mass ranging from 200 ton to 100 kTon. Such detectors
appear as unique for supernova detection, proton decay, LBL neutrino physics
and other astropaticle physics applications.
[8]
oai:arXiv.org:astro-ph/0509410 [pdf] - 75992
A Concept for a Scalable 2 kTon Liquid Argon TPC Detector for
Astroparticle Physics
Submitted: 2005-09-14
This paper describes the results of a study on the general lines, main
construction criteria, crucial points, parameters and required preliminary R&D
activities for the construction of a LAr (liquid argon) imaging detector with
active mass in the 10-100 kTon range. Such detectors are crucial for supernova
detection, proton decay, LBL neutrino physics and other astroparticle physics
applications.
[9]
oai:arXiv.org:astro-ph/0301545 [pdf] - 54516
Mini-LANNDD T40: A detector to measure the neutrino-argon cross section
and the electron-neutrino contamination in the off-axis NuMI beam
Submitted: 2003-01-27, last modified: 2003-04-18
We describe a preliminary study of a 40-ton liquid argon TPC based on the
ICARUS method to use in the NuMI near region in line with the LANNDD project.
This reduced-scale detector, called ``Mini-LANNDD T40'', is designed for R&D
purposes and systematic measures on its response. Safety concerns are a key
issue, which will be discussed as well as a preliminary design of the detector.
Adapted as a near or vertex detector in a neutrino beam, the Mini-LANNDD T40 is
capable of observing the electron-neutrino flux in the off-axis beam, a key to
use for measuring $\sin^2 2 \theta_{13}$ in the future, and measuring the low
energy neutrino-argon cross-section, an important piece of information for
future long baseline experiments.
[10]
oai:arXiv.org:astro-ph/0206124 [pdf] - 49755
Mini-LANNDD: A Very Sensitive Neutrino Detector To Measure sin sup 2(2
theta sub 13)
Submitted: 2002-06-07
The ICARUS Detector at the LGNS will carry out a sensitive search for a sin
sup 2(2 theta sub 13). We describe a small version for the LANNDD proton decay
detector (70kT Liquid Argon) to measure nu sub mu -> nu sub e in a low energy
or off-axis neutrino beam. We find an optimal detector size is 5 kT and at a
distance of about 700 km from a high-energy neutrino source. This detector uses
the ICARUS method.
[11]
oai:arXiv.org:astro-ph/0105442 [pdf] - 42671
LANNDD---A Massive Liquid Argon Detector for Proton Decay, Supernova and
Solar Neutrino Studies, and a Neutrino Factory Detector
Submitted: 2001-05-24
We describe a possible Liquid Argon Neutrino and Nuclear Decay Detector
(LANNDD) that consists of a 70kt magnetized liquid argon tracking detector. The
detector is being designed for the Carlsbad Underground Laboratory.