sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Sergiampietri, F.

Normalized to: Sergiampietri, F.

11 article(s) in total. 107 co-authors, from 1 to 7 common article(s). Median position in authors list is 19,0.

[1]  oai:arXiv.org:1712.01932  [pdf] - 1799803
Backgrounds and pulse shape discrimination in the ArDM liquid argon TPC
Comments: 17 pages, 10 figures
Submitted: 2017-12-02
The ArDM experiment completed a single-phase commissioning run in 2015 with an active liquid argon target of nearly one tonne in mass. The analysis of the data and comparison to simulations allowed for a test of the crucial detector properties and confirmed the low background performance of the setup. The statistical rejection power for electron recoil events using the pulse shape discrimination method was estimated using data from a Cf-252 neutron calibration source. Electron and nuclear recoil band profiles were found to be well described by Gaussian distributions. Employing such a model we derive values for the electron recoil statistical rejection power of more than 10$^8$ in the tonne-scale liquid argon target for events with more than 50 detected photons at a 50% acceptance for nuclear recoils. The Rn-222 emanation rate of the ArDM cryostat at room temperature was found to be 65.6$\pm$0.4 $\mu$Hz/l, and the Ar-39 specific activity from the employed atmospheric argon to be 0.95$\pm$0.05 Bq/kg. The cosmic muon flux at the Canfranc underground site was determined to be between 2 and 3.5$\times 10^{-3}m^{2}s^{-1}$ . These results pave the way for the next physics run of ArDM in the double-phase operational mode.
[2]  oai:arXiv.org:1612.06375  [pdf] - 1551971
The ArDM Liquid Argon Time Projection Chamber at the Canfranc Underground Laboratory: a ton-scale detector for Dark Matter Searches
Comments: 30 pages, 18 figures
Submitted: 2016-12-19
The Argon Dark Matter (ArDM) experiment consists of a liquid argon (LAr) time projection chamber (TPC) sensitive to nuclear recoils resulting from scattering of hypothetical Weakly Interacting Massive Particles (WIMPs) on argon targets. With an active target of 850 kg, ArDM represents an important milestone in the quest for Dark Matter with LAr. We present the experimental apparatus currently installed underground at the Laboratorio Subterraneo de Canfranc (LSC), Spain. We show first data recorded during a single-phase commissioning run in 2015 (ArDM Run I), which overall confirm the good and stable performance of the ton-scale LAr detector.
[3]  oai:arXiv.org:1611.02481  [pdf] - 1510448
Measurement of the attenuation length of argon scintillation light in the ArDM LAr TPC
Comments: 20 pages, 8 figures
Submitted: 2016-11-08
We report on a measurement of the attenuation length for the scintillation light in the tonne size liquid argon target of the ArDM dark matter experiment. The data was recorded in the first underground operation of the experiment in single-phase operational mode. The results were achieved by comparing the light yield spectra from 39-Ar and 83m-Kr to a description of the ArDM setup with a model of full light ray tracing. A relatively low value close to 0.5 m was found for the attenuation length of the liquid argon bulk to its own scintillation light. We interpret this result as a presence of optically active impurities in the liquid argon which are not filtered by the installed purification systems. We also present analyses of the argon gas employed for the filling and discuss cross sections in the vacuum ultraviolet of various molecules in respect to purity requirements in the context of large liquid argon installations.
[4]  oai:arXiv.org:1505.02443  [pdf] - 996764
Status of ArDM-1t: First observations from operation with a full ton-scale liquid argon target
Comments: 16 pages, 18 figures
Submitted: 2015-05-10
ArDM-1t is the first operating ton-scale liquid argon detector for direct search of Dark Matter particles. Developed at CERN as Recognized Experiment RE18, the experiment has been approved in 2010 to be installed in the Spanish underground site LSC (Laboratorio Subterraneo de Canfranc). Under the label of LSC EXP-08-2010 the ArDM detector underwent an intensive period of technical completion and safety approval until the recent filling of the target vessel with almost 2 ton of liquid argon. This report describes the experimental achievements during commissioning of ArDM and the transition into a stage of first physics data taking in single phase operational mode. We present preliminary observations from this run. A first indication for the background discrimination power of LAr detectors at the ton-scale is shown. We present an outlook for completing the detector with the electric drift field and upgrade of the scintillation light readout system with novel detector modules based on SiPMs in order to improve the light yield.
[5]  oai:arXiv.org:0705.2117  [pdf] - 1279
R & D for Future Zeplin
Comments: to appear in Proc. 7th UCLA Symposium on Sources and Detection of Dark Matter and Dark Energy in the Universe, 22-24 February, Marina del Rey, USA; Nucl. Phys. B Proc. Suppl., in press; 4 pages, 3 figues
Submitted: 2007-05-15
We propose a new concept for a very low background multi-ton liquid xenon Dark Matter experiment. The detector consists of two concentric spheres and a charge readout device in the centre. Xenon between the two spheres forms a self-shield and veto device. The inner surface of the central sphere is coated with CsI to form an internal photocathode with minimum of 2\pi coverage for any event in the active volume. Photoelectrons from the CsI photocathode drift toward the charge readout micro-structure in the centre of the detector. Both scintillation and ionisation are measured simultaneously for background rejection and 3-D event mapping. In addition to external shielding, the low background is achieved by eliminating PMTs and by using low radioactivity pure materials throughout the detector. We present detailed calculations of the charge readout system and design details. The detector is expected to probe the full SUSY parameter space.
[6]  oai:arXiv.org:astro-ph/0701858  [pdf] - 88987
First limits on WIMP nuclear recoil signals in ZEPLIN-II: a two phase xenon detector for dark matter detection
Comments: 38 Pages, 16 Figures, (v2: corrected table 2 description)
Submitted: 2007-01-30, last modified: 2007-01-31
Results are presented from the first underground data run of ZEPLIN-II, a 31 kg two phase xenon detector developed to observe nuclear recoils from hypothetical weakly interacting massive dark matter particles. Discrimination between nuclear recoils and background electron recoils is afforded by recording both the scintillation and ionisation signals generated within the liquid xenon, with the ratio of these signals being different for the two classes of event. This ratio is calibrated for different incident species using an AmBe neutron source and Co-60 gamma-ray sources. From our first 31 live days of running ZEPLIN-II, the total exposure following the application of fiducial and stability cuts was 225 kgxdays. A background population of radon progeny events was observed in this run, arising from radon emission in the gas purification getters, due to radon daughter ion decays on the surfaces of the walls of the chamber. An acceptance window, defined by the neutron calibration data, of 50% nuclear recoil acceptance between 5 keVee and 20 keVee, had an observed count of 29 events, with a summed expectation of 28.6+/-4.3 gamma-ray and radon progeny induced background events. These figures provide a 90% c.l. upper limit to the number of nuclear recoils of 10.4 events in this acceptance window, which converts to a WIMP-nucleon spin-independent cross-section with a minimum of 6.6x10^-7 pb following the inclusion of an energy dependent, calibrated, efficiency. A second run is currently underway in which the radon progeny will be eliminated, thereby removing the background population, with a projected sensitivity of 2x10^-7 pb for similar exposures as the first run.
[7]  oai:arXiv.org:astro-ph/0604548  [pdf] - 81617
LANNDD - A line of liquid argon TPC detectors scalable in mass from 200 Tons to 100 Ktons
Comments: PDF, 13 pages with 19 JPEG figures and 1 table
Submitted: 2006-04-26
A scalable line of liquid argon TPC detectors is described, based on a three dimensional cubic frame array immersed on a common liquid argon volume. The paper describes general lines, main construction criteria, crucial points, parameters and required preliminary R&D activities for the construction of detectors with active mass ranging from 200 ton to 100 kTon. Such detectors appear as unique for supernova detection, proton decay, LBL neutrino physics and other astropaticle physics applications.
[8]  oai:arXiv.org:astro-ph/0509410  [pdf] - 75992
A Concept for a Scalable 2 kTon Liquid Argon TPC Detector for Astroparticle Physics
Comments: 5 pages, 4 figures
Submitted: 2005-09-14
This paper describes the results of a study on the general lines, main construction criteria, crucial points, parameters and required preliminary R&D activities for the construction of a LAr (liquid argon) imaging detector with active mass in the 10-100 kTon range. Such detectors are crucial for supernova detection, proton decay, LBL neutrino physics and other astroparticle physics applications.
[9]  oai:arXiv.org:astro-ph/0301545  [pdf] - 54516
Mini-LANNDD T40: A detector to measure the neutrino-argon cross section and the electron-neutrino contamination in the off-axis NuMI beam
Comments: 4 pages, 5 figures, 2 tables
Submitted: 2003-01-27, last modified: 2003-04-18
We describe a preliminary study of a 40-ton liquid argon TPC based on the ICARUS method to use in the NuMI near region in line with the LANNDD project. This reduced-scale detector, called ``Mini-LANNDD T40'', is designed for R&D purposes and systematic measures on its response. Safety concerns are a key issue, which will be discussed as well as a preliminary design of the detector. Adapted as a near or vertex detector in a neutrino beam, the Mini-LANNDD T40 is capable of observing the electron-neutrino flux in the off-axis beam, a key to use for measuring $\sin^2 2 \theta_{13}$ in the future, and measuring the low energy neutrino-argon cross-section, an important piece of information for future long baseline experiments.
[10]  oai:arXiv.org:astro-ph/0206124  [pdf] - 49755
Mini-LANNDD: A Very Sensitive Neutrino Detector To Measure sin sup 2(2 theta sub 13)
Comments: Talk given by D. Cline at the New Initiative Workshop, FNAL, May 2002
Submitted: 2002-06-07
The ICARUS Detector at the LGNS will carry out a sensitive search for a sin sup 2(2 theta sub 13). We describe a small version for the LANNDD proton decay detector (70kT Liquid Argon) to measure nu sub mu -> nu sub e in a low energy or off-axis neutrino beam. We find an optimal detector size is 5 kT and at a distance of about 700 km from a high-energy neutrino source. This detector uses the ICARUS method.
[11]  oai:arXiv.org:astro-ph/0105442  [pdf] - 42671
LANNDD---A Massive Liquid Argon Detector for Proton Decay, Supernova and Solar Neutrino Studies, and a Neutrino Factory Detector
Comments: 8 pages, 5 figures; for the Neutrino Facory Meeting at KEK-NUFACT '01
Submitted: 2001-05-24
We describe a possible Liquid Argon Neutrino and Nuclear Decay Detector (LANNDD) that consists of a 70kt magnetized liquid argon tracking detector. The detector is being designed for the Carlsbad Underground Laboratory.