sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Sennhauser, C.

Normalized to: Sennhauser, C.

2 article(s) in total. 5 co-authors. Median position in authors list is 2,0.

[1]  oai:arXiv.org:1003.5112  [pdf] - 137472
Zeeman Component Decomposition (ZCD) of polarized spectra: Application for the quiet Sun internetwork magnetic field
Comments: 4 pages, 1 figure, SOHO-23 proceedings in press
Submitted: 2010-03-26
Multiline techniques assuming similar line profiles have become a standard tool in stellar astronomy for increasing the signal-to-noise ratio (SNR) of spectropolarimetric measurements. However, due to the widely-used weak field approximation their benefits could not so far be used for solar observations, where a large variety of Stokes profiles emerge from local magnetic fields and measuring weak fields in the quiet Sun remains a challenge. The method presented here permits us to analyze many lines with arbitrary Zeeman splitting and to simultaneously deploy Stokes IQUV spectra to determine a common line profile with the SNR increased by orders of magnitude. The latter provides a valuable constraint for determining separately field strengths for each contributing absorber. This method represents an extension of our recently developed technique of Nonlinear Deconvolution with Deblending (NDD, Sennhauser et al. 2009), which accounts for the nonlinearity in blended profiles. Equipped with all those abilities, ZCD is the perfect tool to further increase the informative value of high-precision polarimetric observations.
[2]  oai:arXiv.org:1002.1409  [pdf] - 1025032
Achromatizing a liquid-crystal spectropolarimeter: Retardance vs Stokes-based calibration of HiVIS
Comments: Accepted in PASP
Submitted: 2010-02-06
Astronomical spectropolarimeters can be subject to many sources of systematic error which limit the precision and accuracy of the instrument. We present a calibration method for observing high-resolution polarized spectra using chromatic liquid-crystal variable retarders (LCVRs). These LCVRs allow for polarimetric modulation of the incident light without any moving optics at frequencies >10Hz. We demonstrate a calibration method using pure Stokes input states that enables an achromatization of the system. This Stokes-based deprojection method reproduces input polarization even though highly chromatic instrument effects exist. This process is first demonstrated in a laboratory spectropolarimeter where we characterize the LCVRs and show example deprojections. The process is then implemented the a newly upgraded HiVIS spectropolarimeter on the 3.67m AEOS telescope. The HiVIS spectropolarimeter has also been expanded to include broad-band full-Stokes spectropolarimetry using achromatic wave-plates in addition to the tunable full-Stokes polarimetric mode using LCVRs. These two new polarimetric modes in combination with a new polarimetric calibration unit provide a much more sensitive polarimetric package with greatly reduced systematic error.