Sennhauser, C.
Normalized to: Sennhauser, C.
2 article(s) in total. 5 co-authors. Median position in authors list is 2,0.
[1]
oai:arXiv.org:1003.5112 [pdf] - 137472
Zeeman Component Decomposition (ZCD) of polarized spectra: Application
for the quiet Sun internetwork magnetic field
Submitted: 2010-03-26
Multiline techniques assuming similar line profiles have become a standard
tool in stellar astronomy for increasing the signal-to-noise ratio (SNR) of
spectropolarimetric measurements. However, due to the widely-used weak field
approximation their benefits could not so far be used for solar observations,
where a large variety of Stokes profiles emerge from local magnetic fields and
measuring weak fields in the quiet Sun remains a challenge. The method
presented here permits us to analyze many lines with arbitrary Zeeman splitting
and to simultaneously deploy Stokes IQUV spectra to determine a common line
profile with the SNR increased by orders of magnitude. The latter provides a
valuable constraint for determining separately field strengths for each
contributing absorber. This method represents an extension of our recently
developed technique of Nonlinear Deconvolution with Deblending (NDD, Sennhauser
et al. 2009), which accounts for the nonlinearity in blended profiles. Equipped
with all those abilities, ZCD is the perfect tool to further increase the
informative value of high-precision polarimetric observations.
[2]
oai:arXiv.org:1002.1409 [pdf] - 1025032
Achromatizing a liquid-crystal spectropolarimeter: Retardance vs
Stokes-based calibration of HiVIS
Submitted: 2010-02-06
Astronomical spectropolarimeters can be subject to many sources of systematic
error which limit the precision and accuracy of the instrument. We present a
calibration method for observing high-resolution polarized spectra using
chromatic liquid-crystal variable retarders (LCVRs). These LCVRs allow for
polarimetric modulation of the incident light without any moving optics at
frequencies >10Hz. We demonstrate a calibration method using pure Stokes input
states that enables an achromatization of the system. This Stokes-based
deprojection method reproduces input polarization even though highly chromatic
instrument effects exist. This process is first demonstrated in a laboratory
spectropolarimeter where we characterize the LCVRs and show example
deprojections. The process is then implemented the a newly upgraded HiVIS
spectropolarimeter on the 3.67m AEOS telescope. The HiVIS spectropolarimeter
has also been expanded to include broad-band full-Stokes spectropolarimetry
using achromatic wave-plates in addition to the tunable full-Stokes
polarimetric mode using LCVRs. These two new polarimetric modes in combination
with a new polarimetric calibration unit provide a much more sensitive
polarimetric package with greatly reduced systematic error.