[1]  oai:arXiv.org:1103.4070  [pdf] - 966535
Final results of the EDELWEISS-II WIMP search using a 4-kg array of cryogenic germanium detectors with interleaved electrodes
Comments: 23 pages, 5 figures; matches published version
Submitted: 2011-03-21, last modified: 2011-08-31
The EDELWEISS-II collaboration has completed a direct search for WIMP dark matter with an array of ten 400-g cryogenic germanium detectors in operation at the Laboratoire Souterrain de Modane. The combined use of thermal phonon sensors and charge collection electrodes with an interleaved geometry enables the efficient rejection of gamma-induced radioactivity as well as near-surface interactions. A total effective exposure of 384 kg.d has been achieved, mostly coming from fourteen months of continuous operation. Five nuclear recoil candidates are observed above 20 keV, while the estimated background is 3.0 events. The result is interpreted in terms of limits on the cross-section of spin-independent interactions of WIMPs and nucleons. A cross-section of 4.4x10^-8 pb is excluded at 90%CL for a WIMP mass of 85 GeV. New constraints are also set on models where the WIMP-nucleon scattering is inelastic.
[2]  oai:arXiv.org:1105.3377  [pdf] - 966800
Combined Limits on WIMPs from the CDMS and EDELWEISS Experiments
CDMS; Collaborations, EDELWEISS; :; Ahmed, Z.; Akerib, D. S.; Armengaud, E.; Arrenberg, S.; Augier, C.; Bailey, C. N.; Balakishiyeva, D.; Baudis, L.; Bauer, D. A.; Benoît, A.; Bergé, L.; Blümer, J.; Brink, P. L.; Broniatowski, A.; Bruch, T.; Brudanin, V.; Bunker, R.; Cabrera, B.; Caldwell, D. O.; Censier, B.; Chapellier, M.; Chardin, G.; Charlieux, F.; Cooley, J.; Coulter, P.; Cox, G. A.; Cushman, P.; Daal, M.; Defay, X.; De Jesus, M.; DeJongh, F.; Di Stefano, P. C. F.; Dolgorouki, Y.; Domange, J.; Dumoulin, L.; Dragowsky, M. R.; Eitel, K.; Fallows, S.; Figueroa-Feliciano, E.; Filippini, J.; Filosofov, D.; Fourches, N.; Fox, J.; Fritts, M.; Gascon, J.; Gerbier, G.; Gironnet, J.; Golwala, S. R.; Gros, M.; Hall, J.; Hennings-Yeomans, R.; Henry, S.; Hertel, S. A.; Hervé, S.; Holmgren, D.; Hsu, L.; Huber, M. E.; Juillard, A.; Kamaev, O.; Kiveni, M.; Kluck, H.; Kos, M.; Kozlov, V.; Kraus, H.; Kudryavtsev, V. A.; Leman, S. W.; Liu, S.; Loaiza, P.; Mahapatra, R.; Mandic, V.; Marnieros, S.; Martinez, C.; McCarthy, K. A.; Mirabolfathi, N.; Moore, D.; Nadeau, P.; Navick, X-F.; Nelson, H.; Nones, C.; Ogburn, R. W.; Olivieri, E.; Pari, P.; Pattavina, L.; Paul, B.; Phipps, A.; Pyle, M.; Qiu, X.; Rau, W.; Reisetter, A.; Ricci, Y.; Robinson, M.; Rozov, S.; Saab, T.; Sadoulet, B.; Sander, J.; Sanglard, V.; Schmidt, B.; Schnee, R. W.; Scorza, S.; Seitz, D. N.; Semikh, S.; Serfass, B.; Sundqvist, K. M.; Tarka, M.; Torrento-Coello, A. S.; Vagneron, L.; Verdier, M. -A.; Walker, R. J.; Wikus, P.; Yakushev, E.; Yellin, S.; Yoo, J.; Young, B. A.; Zhang, J.
Comments: Events, efficiencies, and main limit are available in text format (see README.txt)
Submitted: 2011-05-17, last modified: 2011-07-08
The CDMS and EDELWEISS collaborations have combined the results of their direct searches for dark matter using cryogenic germanium detectors. The total data set represents 614 kg.d equivalent exposure. A straightforward method of combination was chosen for its simplicity before data were exchanged between experiments. The results are interpreted in terms of limits on spin-independent WIMP-nucleon cross-section. For a WIMP mass of 90 GeV/c^2, where this analysis is most sensitive, a cross-section of 3.3 x 10^{-44} cm^2 is excluded at 90% CL. At higher WIMP masses, the combination improves the individual limits, by a factor 1.6 above 700 GeV/c^2. Alternative methods of combining the data provide stronger constraints for some ranges of WIMP masses and weaker constraints for others.
[3]  oai:arXiv.org:1104.4700  [pdf] - 1076194
The Plateau de Bure Neutron Monitor: design, operation and Monte-Carlo simulation
Comments: 37 pages, 14 figures, 5 tables; numerical error in GEANT4 particle sourse corrected, section 4.4 was significantly revised. Submitted to IEEE Transactions on Nuclear Science
Submitted: 2011-04-25, last modified: 2011-07-07
This paper describes the Plateau de Bure Neutron Monitor (PdBNM), an instrument providing continuous ground-level measurements of atmospheric secondary neutron flux resulting from the interaction of primary cosmic rays with the Earth's atmosphere. The detector is installed on the Plateau de Bure (Devoluy mountains, south of France, latitude North 44{\deg} 38' 02", longitude East 5{\deg} 54' 26", altitude 2555 m) as a part of the ASTEP Platform (Altitude Single-event effects Test European Platform), a permanent installation dedicated to the study of the impact of terrestrial natural radiation on microelectronics circuit reliability. The present paper reports the neutron monitor design, its operation since August 2008 and its complete numerical simulation using the Monte Carlo codes GEANT4 and MCNPX. We particularly detail the computation of the neutron monitor detection response function for neutrons, muons, protons and pions, the comparison between GEANT4 and MCNPX numerical results and the evaluation of the PdBNM counting rate a function of both the nature and flux of the incident atmospheric particles.
[4]  oai:arXiv.org:1006.3098  [pdf] - 190656
A detection system to measure muon-induced neutrons for direct Dark Matter searches
Comments: Accepted for publication in Astroparticle Physics; 14 pages, 10 figures
Submitted: 2010-06-15
Muon-induced neutrons constitute a prominent background component in a number of low count rate experiments, namely direct searches for Dark Matter. In this work we describe a neutron detector to measure this background in an underground laboratory, the Laboratoire Souterrain de Modane. The system is based on 1 m3 of Gd-loaded scintillator and it is linked with the muon veto of the EDELWEISS-II experiment for coincident muon detection. The system was installed in autumn 2008 and passed since then a number of commissioning tests proving its full functionality. The data-taking is continuously ongoing and a count rate of the order of 1 muon-induced neutron per day has been achieved.
[5]  oai:arXiv.org:1001.4383  [pdf] - 33100
Monitoring of the thermal neutron flux in the LSM underground laboratory
Comments: submitted to Journal of Physics G: Nuclear and Particle Physics, 8 pages, 4 figures
Submitted: 2010-01-25
This paper describes precise measurements of the thermal neutron flux in the LSM underground laboratory in proximity of the EDELWEISS-II dark matter search experiment together with short measurements at various other locations. Monitoring of the flux of thermal neutrons is accomplished using a mobile detection system with low background proportional counter filled with $^3$He. On average 75 neutrons per day are detected with a background level below 1 count per day (cpd). This provides a unique possibility of a day by day study of variations of the neutron field in a deep underground site. The measured average 4$\pi$ neutron flux per cm$^{2}$ in the proximity of EDELWEISS-II is $\Phi_{MB}=3.57\pm0.05^{stat}\pm0.27^{syst}\times 10^{-6}$ neutrons/sec. We report the first experimental observation that the point-to-point thermal neutron flux at LSM varies by more than a factor two.
[6]  oai:arXiv.org:0912.0805  [pdf] - 157860
First results of the EDELWEISS-II WIMP search using Ge cryogenic detectors with interleaved electrodes
Comments: 14 pages, 3 figures. Submitted to Phys Lett. B
Submitted: 2009-12-04
The EDELWEISS-II collaboration has performed a direct search for WIMP dark matter with an array of ten 400 g heat-and-ionization cryogenic detectors equipped with interleaved electrodes for the rejection of near-surface events. Six months of continuous operation at the Laboratoire Souterrain de Modane have been achieved. The observation of one nuclear recoil candidate above 20 keV in an effective exposure of 144 kgd is interpreted in terms of limits on the cross-section of spin-independent interactions of WIMPs and nucleons. A cross-section of 1.0x10^-7 pb is excluded at 90%CL for a WIMP mass of 80 GeV/c2. This result demonstrates for the first time the very high background rejection capabilities of these simple and robust detectors in an actual WIMP search experiment.
[7]  oai:arXiv.org:0905.0753  [pdf] - 369040
A new high-background-rejection dark matter Ge cryogenic detector
Comments: submitted to Physical Review Letters
Submitted: 2009-05-06
A new design of a cryogenic germanium detector for dark matter search is presented, taking advantage of the coplanar grid technique of event localisation for improved background discrimination. Experiments performed with prototype devices in the EDELWEISS II setup at the Modane underground facility demonstrate the remarkably high efficiency of these devices for the rejection of low-energy $\beta$, approaching 10$^5$ . This opens the road to investigate the range beyond 10$^{-8}$ pb in the WIMP-nucleon collision cross-sections, as proposed in the EURECA project of a one-ton cryogenic detector mass.