Normalized to: Seidel, W.
[1]
oai:arXiv.org:1802.08639 [pdf] - 1639827
A prototype detector for the CRESST-III low-mass dark matter search
Strauss, R.;
Angloher, G.;
Bauer, P.;
Defay, X.;
Erb, A.;
Feilitzsch, F. v.;
Iachellini, N. Ferreiro;
Hampf, R.;
Hauff, D.;
Kiefer, M.;
Lanfranchi, J. -C.;
Langenkämper, A.;
Mondragon, E.;
Münster, A.;
Oppenheimer, C.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Reindl, F.;
Rothe, J.;
Schönert, S.;
Seidel, W.;
Steiger, H.;
Stodolsky, L.;
Tanzke, A.;
Thi, H. H. Trinh;
Ulrich, A.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.;
Zöller, A.
Submitted: 2018-02-23
The CRESST-III experiment which is dedicated to low-mass dark matter search
uses scintillating CaWO$_4$ crystals operated as cryogenic particle detectors.
Background discrimination is achieved by exploiting the scintillating light
signal of CaWO$_4$ and by a novel active detector holder presented in this
paper. In a test setup above ground, a nuclear-recoil energy threshold of
$E_{th}=(190.6\pm5.2)$eV is reached with a 24g prototype detector, which
corresponds to an estimated threshold of $\sim$50eV when being operated in the
low-noise CRESST cryostat. This is the lowest threshold reported for direct
dark matter searches. For CRESST-III phase 1, ten such detector modules were
installed in the cryostat which have the potential to improve significantly the
sensitivity to scatterings of dark matter particles with masses down to
$\sim$0.1GeV/c$^2$.
[2]
oai:arXiv.org:1711.07692 [pdf] - 1591519
First results on low-mass dark matter from the CRESST-III experiment
CRESST collaboration;
Petricca, F.;
Angloher, G.;
Bauer, P.;
Bento, A.;
Bucci, C.;
Canonica, L.;
Defay, X.;
Erb, A.;
Feilitzsch, F. v.;
Iachellini, N. Ferreiro;
Gorla, P.;
Gütlein, A.;
Hauff, D.;
Jochum, J.;
Kiefer, M.;
Kluck, H.;
Kraus, H.;
Lanfranchi, J. C.;
Lagenkämper, A.;
Loebell, J.;
Mancuso, M.;
Mondragon, E.;
Münster, A.;
Pagliarone, C.;
Potzel, W.;
Pröbst, F.;
Puig, R.;
Reindl, F.;
Rothe, J.;
Schäffner, K.;
Schieck, J.;
Schönert, S.;
Seidel, W.;
Stahlberg, M.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Tanzke, A.;
Thi, H. H. Trinh;
Türkoğlu, C.;
Ulrich, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.
Submitted: 2017-11-21
The CRESST experiment, located at Laboratori Nazionali del Gran Sasso in
Italy, searches for dark matter particles via their elastic scattering off
nuclei in a target material. The CRESST target consists of scintillating
CaWO$_4$ crystals, which are operated as cryogenic calorimeters at millikelvin
temperatures. Each interaction in the CaWO$_4$ target crystal produces a phonon
signal and a light signal that is measured by a second cryogenic calorimeter.
Since the CRESST-II result in 2015, the experiment is leading the field of
direct dark matter search for dark matter masses below 1.7\,GeV/$c^2$,
extending the reach of direct searches to the sub-GeV/$c^2$ mass region. For
CRESST-III, whose Phase 1 started in July 2016, detectors have been optimized
to reach the performance required to further probe the low-mass region with
unprecedented sensitivity. In this contribution the achievements of the
CRESST-III detectors will be discussed together with preliminary results and
perspectives of Phase 1.
[3]
oai:arXiv.org:1711.01285 [pdf] - 1590722
Search for low-mass Dark Matter with the CRESST Experiment
Kluck, H.;
Angloher, G.;
Bauer, P.;
Bento, A.;
Bucci, C.;
Canonica, L.;
Defay, X.;
Erb, A.;
Feilitzsch, F. v.;
Iachellini, N. Ferreiro;
Gorla, P.;
Gütlein, A.;
Hauff, D.;
Jochum, J.;
Kiefer, M.;
Kraus, H.;
Lanfranchi, J. -C.;
Langenkämper, A.;
Loebell, J.;
Mancuso, M.;
Mondragon, E.;
Münster, A.;
Pagliarone, C.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Puig, R.;
Reindl, F.;
Rothe, J.;
Schäffner, K.;
Schieck, J.;
Schönert, S.;
Seidel, W.;
Stahlberg, M.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Tanzke, A.;
Thi, H. H. Trinh;
Türkoğlu, C.;
Ulrich, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.
Submitted: 2017-11-03
CRESST is a multi-stage experiment directly searching for dark matter (DM)
using cryogenic $\mathrm{CaWO_4}$ crystals. Previous stages established leading
limits for the spin-independent DM-nucleon cross section down to DM-particle
masses $m_\mathrm{DM}$ below $1\,\mathrm{GeV/c^2}$. Furthermore, CRESST
performed a dedicated search for dark photons (DP) which excludes new parameter
space between DP masses $m_\mathrm{DP}$ of $300\,\mathrm{eV/c^2}$ to
$700\,\mathrm{eV/c^2}$.
In this contribution we will discuss the latest results based on the previous
CRESST-II phase 2 and we will report on the status of the current CRESST-III
phase 1: in this stage we have been operating 10 upgraded detectors with
$24,\mathrm{g}$ target mass each and enhanced detector performance since summer
2016. The improved detector design in terms of background suppression and
reduction of the detection threshold will be discussed with respect to the
previous stage. We will conclude with an outlook on the potential of the next
stage, CRESST-III phase 2.
[4]
oai:arXiv.org:1707.06749 [pdf] - 1586208
Results on MeV-scale dark matter from a gram-scale cryogenic calorimeter
operated above ground
Angloher, G.;
Bauer, P.;
Bento, A.;
Bucci, C.;
Canonica, L.;
Defay, X.;
Erb, A.;
Feilitzsch, F. v.;
Iachellini, N. Ferreiro;
Gorla, P.;
Gütlein, A.;
Hauff, D.;
Jochum, J.;
Kiefer, M.;
Kluck, H.;
Kraus, H.;
Lanfranchi, J. -C.;
Loebell, A. Langenkämper J.;
Mancuso, M.;
Mondragon, E.;
Münster, A.;
Oberauer, L.;
Pagliarone, C.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Puig, R.;
Reindl, F.;
Rothe, J.;
Schäffner, K.;
Schieck, J.;
Schönert, S.;
Seidel, W.;
Stahlberg, M.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Tanzke, A.;
Thi, H. H. Trinh;
Türkoglu, C.;
Uffinger, M.;
Ulrich, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.;
Zöller, A.
Submitted: 2017-07-20, last modified: 2017-09-18
Models for light dark matter particles with masses below 1 GeV/c$^2$ are a
natural and well-motivated alternative to so-far unobserved weakly interacting
massive particles. Gram-scale cryogenic calorimeters provide the required
detector performance to detect these particles and extend the direct dark
matter search program of CRESST. A prototype 0.5 g sapphire detector developed
for the $\nu$-cleus experiment has achieved an energy threshold of
$E_{th}=(19.7\pm 0.9)$ eV, which is one order of magnitude lower than previous
results and independent of the type of particle interaction. The result
presented here is obtained in a setup above ground without significant
shielding against ambient and cosmogenic radiation. Although operated in a
high-background environment, the detector probes a new range of light-mass dark
matter particles previously not accessible by direct searches. We report the
first limit on the spin-independent dark matter particle-nucleon cross section
for masses between 140 MeV/c$^2$ and 500 MeV/c$^2$.
[5]
oai:arXiv.org:1708.01581 [pdf] - 1586787
Performance of a CRESST-II Detector Module with True $4\pi$-veto
Angloher, G.;
Bauer, P.;
Bento, A.;
Bucci, C.;
Canonica, L.;
Defay, X.;
Erb, A.;
Feilitzsch, F. v.;
Iachellini, N. Ferreiro;
Gorla, P.;
Gütlein, A.;
Hauff, D.;
Jochum, J.;
Kiefer, M.;
Kluck, H.;
Kraus, H.;
Lanfranchi, J. C.;
Langenkämper, A.;
Loebell, J.;
Mancuso, M.;
Münster, A.;
Pagliarone, C.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Reindl, F.;
Rothe, J.;
Schäffner, K.;
Schieck, J.;
Schönert, V. Schipperges S.;
Seidel, W.;
Stahlberg, M.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Tanzke, A.;
Thi, H. H. Trinh;
Türkoğlu, C.;
Uffinger, M.;
Ulrich, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.;
Zöller, A.
Submitted: 2017-08-04
Scintillating, cryogenic bolometers are widely used in the field of rare
event searches. Their main advantages are an excellent energy resolution and
particle identification on an event-by-event basis. The sensitivity of
experiments applying this detector technique can be limited by the performance
of the light channel and the presence of external backgrounds in the region of
interest. In the framework of the CRESST-II experiment, we developed and
successfully tested a novel detector design addressing both challenges. Using a
large scale ($\approx$\unit[60]{cm$^2$}), beaker-shaped silicon light absorber,
the signal height recorded in the light channel is improved by a factor 2.5
compared to conventional CRESTT-II detector modules. In combination with a
large carrier crystal, a true $4\pi$ veto system is established which allows to
tag external background sources.
[6]
oai:arXiv.org:1503.07806 [pdf] - 1530245
In-situ study of light production and transport in phonon/light detector
modules for dark matter search
Kiefer, M.;
Angloher, G.;
Bento, A.;
Bucci, C.;
Canonica, L.;
Erb, A.;
Feilitzsch, F. v.;
Iachellini, N. Ferreiro;
Gorla, P.;
Gütlein, A.;
Hauff, D.;
Jochum, J.;
Kluck, H.;
Kraus, H.;
Lanfranchi, J. -C.;
Loebell, J.;
Münster, A.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Reindl, F.;
Roth, S.;
Rottler, K.;
Sailer, C.;
Schäffner, K.;
Schieck, J.;
Schönert, S.;
Seidel, W.;
Sivers, M. v.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Tanzke, A.;
Türkoğlu, C.;
Uffinger, M.;
Ulrich, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.;
Zöller, A.
Submitted: 2015-03-26, last modified: 2017-02-20
The CRESST experiment (Cryogenic Rare Event Search with Superconducting
Thermometers) searches for dark matter via the phonon and light signals of
elastic scattering processes in scintillating crystals. The discrimination
between a possible dark matter signal and background is based on the light
yield. We present a new method for evaluating the two characteristics of a
phonon/light detector module that determine how much of the deposited energy is
converted to scintillation light and how efficiently a module detects the
produced light. In contrast to former approaches with dedicated setups, we
developed a method which allows us to use data taken with the cryogenic setup,
during a dark matter search phase. In this way, we accounted for the entire
process that occurs in a detector module, and obtained information on the light
emission of the crystal as well as information on the performance of the module
(light transport and detection). We found that with the detectors operated in
CRESST-II phase 1, about 20% of the produced scintillation light is detected. A
part of the light is likely absorbed by creating meta-stable excitations in the
scintillating crystals. The light not detected is not absorbed entirely, as an
additional light detector can help to increase the fraction of detected light.
[7]
oai:arXiv.org:1611.02113 [pdf] - 1509578
Direct Dark Matter Search with the CRESST II Experiment
Schieck, J;
Angloher, G;
Bento, A;
Bucci, C;
Canonica, L;
Defay, X;
Erb, A;
Feilitzsch, F v;
Iachellini, N Ferreiro;
Gorla, P;
Guetlein, A;
Hauff, D;
Jochum, J;
Kiefer, M;
Kluck, H;
Kraus, H;
Lanfranchi, J-C;
Loebell, J;
Mancuso, M;
Muenster, A;
Pagliarone, C;
Petricca, F;
Potzel, W;
Pröbst, F;
Puig, R;
Reindl, F;
Schaeffner, K;
Schoenert, S;
Seidel, W;
Stahlberg, M;
Stodolsky, L;
Strandhagen, C;
Strauss, R;
Tanzke, A;
Thi, H H Trinh;
Turkoglu, C;
Uffinger, M;
Ulrich, A;
Usherov, I;
Wawoczny, S;
Willers, M;
Wueustrich, M;
Zoeller, A
Submitted: 2016-11-07
The quest for the particle nature of dark matter is one of the big open
questions of modern physics. A well motivated candidate for dark matter is the
so-called WIMP - a weakly interacting massive particle. Recently several
theoretically well-motivated models with dark matter candidates in a mass
region below the WIMP mass-scale gained also a lot of interest, theoretically
and experimentally. The CRESST II experiment located at the Gran Sasso
laboratory in Italy is optimised for the detection of the elastic scattering of
these low-mass dark matter particles with ordinary matter. We show the results
obtained with an improved detector setup with increased radio purity and
enhanced background rejection and the results obtained with a dedicated
low-threshold analysis of a single conventional detector module. The limit
achieved is the most stringent limit achieved for direct dark matter
experiments in the mass region below 1.8 GeV/$c^{2}$. We will discuss the
expected performance for new small CRESST-type detectors to be used during the
next data taking phase. We conclude with an outlook of the future potential for
direct dark matter detection using further improved CRESST CaWO$_{4}$ cryogenic
detectors.
[8]
oai:arXiv.org:1610.03876 [pdf] - 1580394
The COSINUS project - a NaI-based cryogenic calorimeter for direct dark
matter detection
Angloher, G.;
Carniti, P.;
Cassina, L.;
Gironi, L.;
Gotti, C.;
Gütlein, A.;
Hauff, D.;
Maino, M.;
Nagorny, S. S.;
Pagnanini, L.;
Pessina, G.;
Petricca, F.;
Pirro, S.;
Pröbst, F.;
Reindl, F.;
Schäffner, K.;
Schieck, J.;
Seidel, W.
Submitted: 2016-10-12
At present the results in the field of direct dark matter search are in
tension: the positive claim of DAMA/LIBRA versus null results from other
experiments. However, the comparison of the results of different experiments
involves model dependencies, in particular because of the different target
materials in use. The COSINUS R&D project aims to operate NaI as a cryogenic
calorimeter. Such a detector would not only allow for a direct comparison to
DAMA/LIBRA, but would also provide a low(er) nuclear recoil threshold and
particle discrimination.
[9]
oai:arXiv.org:1601.04447 [pdf] - 1439730
Limits on momentum-dependent asymmetric dark matter with CRESST-II
Angloher, G.;
Bento, A.;
Bucci, C.;
Canonica, L.;
Defay, X.;
Erb, A.;
Feilitzsch, F. v.;
Iachellini, N. Ferreiro;
Gorla, P.;
Gütlein, A.;
Hauff, D.;
Jochum, J.;
Kiefer, M.;
Kluck, H.;
Kraus, H.;
Lanfranchi, J. -C.;
Loebell, J.;
Münster, A.;
Pagliarone, C.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Reindl, F.;
Schäffner, K.;
Schieck, J.;
Schönert, S.;
Seidel, W.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Tanzke, A.;
Thi, H. H. Trinh;
Türkoğlu, C.;
Uffinger, M.;
Ulrich, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.;
Zöller, A.
Submitted: 2016-01-18, last modified: 2016-07-19
The usual assumption in direct dark matter searches is to only consider the
spin-dependent or spin-independent scattering of dark matter particles.
However, especially in models with light dark matter particles
$\mathcal{O}(\mathrm{GeV/c^2})$, operators which carry additional powers of the
momentum transfer $q^2$ can become dominant. One such model based on asymmetric
dark matter has been invoked to overcome discrepancies in helioseismology and
an indication was found for a particle with preferred mass of 3
$\mathrm{GeV/c^2}$ and cross section of $10^{-37} \mathrm{cm^2}$. Recent data
from the CRESST-II experiment, which uses cryogenic detectors based on
$\mathrm{CaWO_4}$ to search for nuclear recoils induced by dark matter
particles, are used to constrain these momentum-dependent models. The low
energy threshold of 307 eV for nuclear recoils of the detector used, allows us
to rule out the proposed best fit value above.
[10]
oai:arXiv.org:1509.01515 [pdf] - 1357396
Results on light dark matter particles with a low-threshold CRESST-II
detector
The CRESST Collaboration;
Angloher, G.;
Bento, A.;
Bucci, C.;
Canonica, L.;
Defay, X.;
Erb, A.;
Feilitzsch, F. v.;
Iachellini, N. Ferreiro;
Gorla, P.;
Gütlein, A.;
Hauff, D.;
Jochum, J.;
Kiefer, M.;
Kluck, H.;
Kraus, H.;
Lanfranchi, J. C.;
Loebell, J.;
Münster, A.;
Pagliarone, C.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Reindl, F.;
Schäffner, K.;
Schieck, J.;
Schönert, S.;
Seidel, W.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Tanzke, A.;
Thi, H. H. Trinh;
Türkoğlu, C.;
Uffinger, M.;
Ulrich, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.;
Zöller, A.
Submitted: 2015-09-04, last modified: 2016-02-12
The CRESST-II experiment uses cryogenic detectors to search for nuclear
recoil events induced by the elastic scattering of dark matter particles in
CaWO$_4$ crystals. Given the low energy threshold of our detectors in
combination with light target nuclei, low mass dark matter particles can be
probed with high sensitivity. In this letter we present the results from data
of a single detector module corresponding to 52 kg live days. A blind analysis
is carried out. With an energy threshold for nuclear recoils of 307 eV we
substantially enhance the sensitivity for light dark matter. Thereby, we extend
the reach of direct dark matter experiments to the sub-region and demonstrate
that the energy threshold is the key parameter in the search for low mass dark
matter particles.
[11]
oai:arXiv.org:1410.1753 [pdf] - 1345768
A detector module with highly efficient surface-alpha event rejection
operated in CRESST-II Phase 2
Strauss, R.;
Angloher, G.;
Bento, A.;
Bucci, C.;
Canonica, L.;
Erb, A.;
Feilitzsch, F. v.;
Ferreiro, N.;
Gorla, P.;
Gütlein, A.;
Hauff, D.;
Jochum, J.;
Kiefer, M.;
Kluck, H.;
Kraus, H.;
Lanfranchi, J. -C.;
Loebell, J.;
Münster, A.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Reindl, F.;
Roth, S.;
Rottler, K.;
Sailer, C.;
Schäffner, K.;
Schieck, J.;
Scholl, S.;
Schönert, S.;
Seidel, W.;
Sivers, M. v.;
Stanger, M.;
Stodolsky, L.;
Strandhagen, C.;
Tanzke, A.;
Uffinger, M.;
Ulrich, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.;
Zöller, A.
Submitted: 2014-10-07, last modified: 2016-01-25
The cryogenic dark matter experiment CRESST-II aims at the direct detection
of WIMPs via elastic scattering off nuclei in scintillating CaWO$_4$ crystals.
We present a new, highly improved, detector design installed in the current run
of CRESST-II Phase 2 with an efficient active rejection of surface-alpha
backgrounds. Using CaWO$_4$ sticks instead of metal clamps to hold the target
crystal, a detector housing with fully-scintillating inner surface could be
realized. The presented detector (TUM40) provides an excellent threshold of
${\sim}\,0.60\,$keV and a resolution of $\sigma\,{\approx}\,0.090$ keV (at
2.60$\,$keV). With significantly reduced background levels, TUM40 sets
stringent limits on the spin-independent WIMP-nucleon scattering cross section
and probes a new region of parameter space for WIMP masses below
3$\,$GeV/c$^2$. In this paper, we discuss the novel detector design and the
surface-alpha event rejection in detail.
[12]
oai:arXiv.org:1401.3332 [pdf] - 1345758
Energy-Dependent Light Quenching in CaWO$_4$ Crystals at mK Temperatures
Strauss, R.;
Angloher, G.;
Bento, A.;
Bucci, C.;
Canonica, L.;
Carli, W.;
Ciemniak, C.;
Erb, A.;
Feilitzsch, F. v.;
Gorla, P.;
Gütlein, A.;
Hagn, H.;
Hauff, D.;
Hellgartner, D.;
Jochum, J.;
Kraus, H.;
Lanfranchi, J. -C.;
Loebell, J.;
Münster, A.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Reindl, F.;
Roth, S.;
Rottler, K.;
Sailer, C.;
Schäffner, K.;
Schieck, J.;
Scholl, S.;
Schönert, S.;
Seidel, W.;
Sivers, M. v.;
Stodolsky, L.;
Strandhagen, C.;
Tanzke, A.;
Uffinger, M.;
Ulrich, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.;
Zöller, A.
Submitted: 2014-01-14, last modified: 2016-01-25
Scintillating CaWO$_4$ single crystals are a promising multi-element target
for rare-event searches and are currently used in the direct Dark Matter
experiment CRESST (Cryogenic Rare Event Search with Superconducting
Thermometers). The relative light output of different particle interactions in
CaWO$_4$ is quantified by Quenching Factors (QFs). These are essential for an
active background discrimination and the identification of a possible signal
induced by weakly interacting massive particles (WIMPs). We present the first
precise measurements of the QFs of O, Ca and W at mK temperatures by
irradiating a cryogenic detector with a fast neutron beam. A clear energy
dependence of the QF of O and, less pronounced, of Ca was observed for the
first time. Furthermore, in CRESST neutron-calibration data a variation of the
QFs among different CaWO$_4$ single crystals was found. For typical CRESST
detectors the QFs in the region-of-interest (10-40$\,$keV) are
$QF_O^{ROI}=(11.2{\pm}0.5)\,$%, $QF_{Ca}^{ROI}=(5.94{\pm}0.49)\,$% and
$QF_W^{ROI}=(1.72{\pm}0.21)\,$%. The latest CRESST data (run32) is reanalyzed
using these fundamentally new results on light quenching in CaWO$_4$ having
moderate influence on the WIMP analysis. Their relevance for future CRESST runs
and for the clarification of previously published results of direct Dark Matter
experiments is emphasized.
[13]
oai:arXiv.org:1509.09124 [pdf] - 1286174
The CRESST Dark Matter Search - Status and Perspectives
The CRESST Collaboration;
Reindl, F.;
Angloher, G.;
Bento, A.;
Bucci, C.;
Canonica, L.;
Defay, X.;
Erb, A.;
Feilitzsch, F. v.;
Iachellini, N. Ferreiro;
Gorla, P.;
Gütlein, A.;
Hauff, D.;
Jochum, J.;
Kiefer, M.;
Kluck, H.;
Kraus, H.;
Lanfranchi, J. C.;
Loebell, J.;
Münster, A.;
Pagliarone, C.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Schäffner, K.;
Schieck, J.;
Schönert, S.;
Seidel, W.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Tanzke, A.;
Thi, H. H. Trinh;
Türkoğlu, C.;
Uffinger, M.;
Ulrich, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.;
Zöller, A.
Submitted: 2015-09-30
In the past years the spotlight of the search for dark matter particles
widened to the low mass region, both from theoretical and experimental side. We
discuss results from data obtained in 2013 with a single detector TUM40. This
detector is equipped with a new upgraded holding scheme to efficiently veto
backgrounds induced by surface alpha decays. This veto, the low threshold of
0.6keV and an unprecedented background level for CaWO$_4$ target crystals
render TUM40 the detector with the best overall performance of CRESST-II phase
2 (July 2013 - August 2015). A low-threshold analysis allowed to investigate
light dark matter particles (<3GeV/c$^2$), previously not accessible for other
direct detection experiments.
[14]
oai:arXiv.org:1503.08065 [pdf] - 972114
Probing low WIMP masses with the next generation of CRESST detector
The CRESST Collaboration;
Angloher, G.;
Bento, A.;
Bucci, C.;
Canonica, L.;
Erb, A.;
Feilitzsch, F. v.;
Iachellini, N. Ferreiro;
Gorla, P.;
Gütlein, A.;
Hauff, D.;
Jochum, J.;
Kiefer, M.;
Kluck, H.;
Kraus, H.;
Lanfranchi, J. -C.;
Loebell, J.;
Münster, A.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Reindl, F.;
Schäffner, K.;
Schieck, J.;
Scholl, S.;
Schönert, S.;
Seidel, W.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Tanzke, A.;
Uffinger, M.;
Ulrich, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.;
Zöller, A.
Submitted: 2015-03-27
The purpose of this document is to describe the upgrade of the CRESST dark
matter search at LNGS. The proposed strategy will allow to explore a region of
the parameter space for spin-independent WIMP-nucleon elastic scattering
corresponding to WIMP masses below 10GeV/c$^\text{2}$, that has not been
covered by other experiments. These results can be achieved only with
outstanding detector performances in terms of threshold and background. This
proposal shows how CRESST can match these performance requirements, adding a
unique piece of information to the dark matter puzzle. The results of this
program will fix a new state-of-the-art in the low mass WIMP exploration,
opening new perspectives of understanding the dark matter scenario.
[15]
oai:arXiv.org:1407.3146 [pdf] - 925077
Results on low mass WIMPs using an upgraded CRESST-II detector
CRESST Collaboration;
Angloher, G.;
Bento, A.;
Bucci, C.;
Canonica, L.;
Erb, A.;
Feilitzsch, F. v.;
Iachellini, N. Ferreiro;
Gorla, P.;
Gütlein, A.;
Hauff, D.;
Huff, P.;
Jochum, J.;
Kiefer, M.;
Kister, C.;
Kluck, H.;
Kraus, H.;
Lanfranchi, J. -C.;
Loebell, J.;
Münster, A.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Reindl, F.;
Roth, S.;
Rottler, K.;
Sailer, C.;
Schäffner, K.;
Schieck, J.;
Schmaler, J.;
Scholl, S.;
Schönert, S.;
Seidel, W.;
Sivers, M. v.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Tanzke, A.;
Uffinger, M.;
Ulrich, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.;
Zöller, A.
Submitted: 2014-07-11, last modified: 2015-01-22
The CRESST-II cryogenic dark matter search aims for the detection of WIMPs
via elastic scattering off nuclei in CaWO$_4$ crystals. We present results from
a low-threshold analysis of a single upgraded detector module. This module
efficiently vetoes low energy backgrounds induced by $\alpha$-decays on inner
surfaces of the detector. With an exposure of \unit[29.35]{kg live days}
collected in 2013 we set a limit on spin-independent WIMP-nucleon scattering
which probes a new region of parameter space for WIMP masses below
\unit[3]{GeV/c$^2$}, previously not covered in direct detection searches. A
possible excess over background discussed for the previous CRESST-II phase 1
(from 2009 to 2011) is not confirmed.
[16]
oai:arXiv.org:1403.5114 [pdf] - 1175712
Radiopurity of CaWO$_4$ Crystals for Direct Dark Matter Search with
CRESST and EURECA
Münster, A.;
Sivers, M. v.;
Angloher, G.;
Bento, A.;
Bucci, C.;
Canonica, L.;
Erb, A.;
Feilitzsch, F. v.;
Gorla, P.;
Gütlein, A.;
Hauff, D.;
Jochum, J.;
Kraus, H.;
Lanfranchi, J. -C.;
Laubenstein, M.;
Loebell, J.;
Ortigoza, Y.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Puimedon, J.;
Reindl, F.;
Roth, S.;
Rottler, K.;
Sailer, C.;
Schäffner, K.;
Schieck, J.;
Scholl, S.;
Schönert, S.;
Seidel, W.;
Stodolsky, L.;
Strandhagen, C.;
Strauss, R.;
Tanzke, A.;
Uffinger, M.;
Ulrich, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Wüstrich, M.;
Zöller, A.
Submitted: 2014-03-20, last modified: 2014-05-07
The direct dark matter search experiment CRESST uses scintillating CaWO$_4$
single crystals as targets for possible WIMP scatterings. An intrinsic
radioactive contamination of the crystals as low as possible is crucial for the
sensitivity of the detectors. In the past CaWO$_4$ crystals operated in CRESST
were produced by institutes in Russia and the Ukraine. Since 2011 CaWO$_4$
crystals have also been grown at the crystal laboratory of the Technische
Universit\"at M\"unchen (TUM) to better meet the requirements of CRESST and of
the future tonne-scale multi-material experiment EURECA. The radiopurity of the
raw materials and of first TUM-grown crystals was measured by ultra-low
background $\gamma$-spectrometry. Two TUM-grown crystals were also operated as
low-temperature detectors at a test setup in the Gran Sasso underground
laboratory. These measurements were used to determine the crystals' intrinsic
$\alpha$-activities which were compared to those of crystals produced at other
institutes. The total $\alpha$-activities of TUM-grown crystals as low as 1.23
$\pm$ 0.06 mBq/kg were found to be significantly smaller than the activities of
crystals grown at other institutes typically ranging between ~15 mBq/kg and ~35
mBq/kg.
[17]
oai:arXiv.org:1203.6835 [pdf] - 1117668
The CRESST II Dark Matter Search
Stodolsky, Leo;
Angloher, G.;
Bauer, M.;
Bavykina, I.;
Bento, A.;
Bucci, C.;
Ciemniak, C.;
Deuter, G.;
Feilitzsch, F. v.;
Hauff, D.;
Huff, P.;
Isaila, C.;
Jochum, J.;
Kiefer, M.;
Kimmerle, M.;
Lanfranchi, J. C.;
Pfister, S.;
Petricca, F.;
Potzel, W.;
Proebst, F.;
Reindl, F.;
Roth, S.;
Rottler, K.;
Sailer, C.;
Schaeffner, K.;
Schmaler, J.;
Scholl, S.;
Seidel, W.;
Sivers, M. v.;
Strandhagen, C.;
Strauss, R.;
Tanzke, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Zoeller, A.
Submitted: 2012-03-30
Direct Dark Matter detection with cryodetectors is briefly discussed, with
particular mention of the possibility of the identification of the recoil
nucleus. Preliminary results from the CREEST II Dark Matter search, with 730
kg-days of data, are presented. Major backgrounds and methods of identifying
and dealing with them are indicated.
[18]
oai:arXiv.org:1109.0702 [pdf] - 1083810
Results from 730 kg days of the CRESST-II Dark Matter Search
Angloher, G.;
Bauer, M.;
Bavykina, I.;
Bento, A.;
Bucci, C.;
Ciemniak, C.;
Deuter, G.;
von Feilitzsch, F.;
Hauff, D.;
Huff, P.;
Isaila, C.;
Jochum, J.;
Kiefer, M.;
Kimmerle, M.;
Lanfranchi, J. -C.;
Petricca, F.;
Pfister, S.;
Potzel, W.;
Pröbst, F.;
Reindl, F.;
Roth, S.;
Rottler, K.;
Sailer, C.;
Schäffner, K.;
Schmaler, J.;
Scholl, S.;
Seidel, W.;
von Sivers, M.;
Stodolsky, L.;
Strandhagen, C.;
Strauß, R.;
Tanzke, A.;
Usherov, I.;
Wawoczny, S.;
Willers, M.;
Zöller, A.
Submitted: 2011-09-04
The CRESST-II cryogenic Dark Matter search, aiming at detection of WIMPs via
elastic scattering off nuclei in CaWO$_4$ crystals, completed 730 kg days of
data taking in 2011. We present the data collected with eight detector modules,
each with a two-channel readout; one for a phonon signal and the other for
coincidently produced scintillation light. The former provides a precise
measure of the energy deposited by an interaction, and the ratio of
scintillation light to deposited energy can be used to discriminate different
types of interacting particles and thus to distinguish possible signal events
from the dominant backgrounds. Sixty-seven events are found in the acceptance
region where a WIMP signal in the form of low energy nuclear recoils would be
expected. We estimate background contributions to this observation from four
sources: 1) "leakage" from the e/\gamma-band 2) "leakage" from the
\alpha-particle band 3) neutrons and 4) Pb-206 recoils from Po-210 decay. Using
a maximum likelihood analysis, we find, at a high statistical significance,
that these sources alone are not sufficient to explain the data. The addition
of a signal due to scattering of relatively light WIMPs could account for this
discrepancy, and we determine the associated WIMP parameters.
[19]
oai:arXiv.org:0912.3689 [pdf] - 125372
Status of the CRESST Dark Matter Search
Schmaler, J.;
Angloher, G.;
Bauer, M.;
Bavykina, I.;
Bento, A.;
Brown, A.;
Bucci, C.;
Ciemniak, C.;
Coppi, C.;
Deuter, G.;
von Feilitzsch, F.;
Hauff, D.;
Henry, S.;
Huff, P.;
Imber, J.;
Ingleby, S.;
Isaila, C.;
Jochum, J.;
Kiefer, M.;
Kimmerle, M.;
Kraus, H.;
Lanfranchi, J. -C.;
Lang, R. F.;
Malek, M.;
McGowan, R.;
Mikhailik, V. B.;
Pantic, E.;
Petricca, F.;
Pfister, S.;
Potzel, W.;
Pröbst, F.;
Roth, S.;
Rottler, K.;
Sailer, C.;
Schäffner, K.;
Scholl, S.;
Seidel, W.;
Stodolsky, L.;
Tolhurst, A. J. B.;
Usherov, I.;
Westphal, W.
Submitted: 2009-12-18
The CRESST experiment aims for a detection of dark matter in the form of
WIMPs. These particles are expected to scatter elastically off the nuclei of a
target material, thereby depositing energy on the recoiling nucleus. CRESST
uses scintillating CaWO4 crystals as such a target. The energy deposited by an
interacting particle is primarily converted to phonons which are detected by
transition edge sensors. In addition, a small fraction of the interaction
energy is emitted from the crystals in the form of scintillation light which is
measured in coincidence with the phonon signal by a separate cryogenic light
detector for each target crystal. The ratio of light to phonon energy permits
the discrimination between the nuclear recoils expected from WIMPs and events
from radioactive backgrounds which primarily lead to electron recoils. CRESST
has shown the success of this method in a commissioning run in 2007 and, since
then, further investigated possibilities for an even better suppression of
backgrounds. Here, we report on a new class of background events observed in
the course of this work. The consequences of this observation are discussed and
we present the current status of the experiment.
[20]
oai:arXiv.org:0912.0170 [pdf] - 971925
Composite CaWO4 Detectors for the CRESST-II Experiment
Kiefer, M.;
Angloher, G.;
Bauer, M.;
Bavykina, I.;
Bento, A.;
Brown, A.;
Bucci, C.;
Ciemniak, C.;
Coppi, C.;
Deuter, G.;
von Feilitzsch, F.;
Hauff, D.;
Henry, S.;
Huff, P.;
Imber, J.;
Ingleby, S.;
Isaila, C.;
Jochum, J.;
Kimmerle, M.;
Kraus, H.;
Lanfranchi, J. -C.;
Lang, R. F.;
Malek, M.;
McGowan, R.;
Mikhailik, V. B.;
Pantic, E.;
Petricca, F.;
Pfister, S.;
Potzel, W.;
Pröbst, F.;
Roth, S.;
Rottler, K.;
Sailer, C.;
Schäffner, K.;
Schmaler, J.;
Scholl, S.;
Seidel, W.;
Stodolsky, L.;
Tolhurst, A. J. B.;
Usherov, I.;
Westphal, W.
Submitted: 2009-12-01
CRESST-II, standing for Cryogenic Rare Events Search with Superconducting
Thermometers phase II, is an experiment searching for Dark Matter. In the LNGS
facility in Gran Sasso, Italy, a cryogenic detector setup is operated in order
to detect WIMPs by elastic scattering off nuclei, generating phononic lattice
excitations and scintillation light. The thermometers used in the experiment
consist of a tungsten thin-film structure evaporated onto the CaWO4 absorber
crystal. The process of evaporation causes a decrease in the scintillation
light output. This, together with the need of a big-scale detector production
for the upcoming EURECA experiment lead to investigations for producing
thermometers on smaller crystals which are glued onto the absorber crystal. In
our Run 31 we tested composite detectors for the first time in the Gran Sasso
setup. They seem to produce higher light yields as hoped and could provide an
additional time based discrimination mechanism for low light yield clamp
events.
[21]
oai:arXiv.org:0906.3290 [pdf] - 25381
Search for Dark Matter with CRESST
Submitted: 2009-06-17
The search for direct interactions of dark matter particles remains one of
the most pressing challenges of contemporary experimental physics. A variety of
different approaches is required to probe the available parameter space and to
meet the technological challenges. Here, we review the experimental efforts
towards the detection of direct dark matter interactions using scintillating
crystals at cryogenic temperatures. We outline the ideas behind these detectors
and describe the principles of their operation. Recent developments are
summarized and various results from the search for rare processes are
presented. In the search for direct dark matter interactions, the CRESST-II
experiment delivers competitive limits, with a sensitivity below 5x10^(-7) pb
on the coherent WIMP-nucleon cross section.
[22]
oai:arXiv.org:0905.4282 [pdf] - 24648
Electron and Gamma Background in CRESST Detectors
Lang, R. F.;
Angloher, G.;
Bauer, M.;
Bavykina, I.;
Bento, A.;
Brown, A.;
Bucci, C.;
Ciemniak, C.;
Coppi, C.;
Deuter, G.;
von Feilitzsch, F.;
Hauff, D.;
Henry, S.;
Huff, P.;
Imber, J.;
Ingleby, S.;
Isaila, C.;
Jochum, J.;
Kiefer, M.;
Kimmerle, M.;
Kraus, H.;
Lanfranchi, J. -C.;
Majorovits, B.;
Malek, M.;
McGowan, R.;
Mikhailik, V. B.;
Pantic, E.;
Petricca, F.;
Pfister, S.;
Potzel, W.;
Pröbst, F.;
Roth, S.;
Rottler, K.;
Sailer, C.;
Schäffner, K.;
Schmaler, J.;
Scholl, S.;
Seidel, W.;
Stodolsky, L.;
Tolhurst, A. J. B.;
Usherov, I.;
Westphal, W.
Submitted: 2009-05-26
The CRESST experiment monitors 300g CaWO_4 crystals as targets for particle
interactions in an ultra low background environment. In this paper, we analyze
the background spectra that are recorded by three detectors over many weeks of
data taking. Understanding these spectra is mandatory if one wants to further
reduce the background level, and allows us to cross-check the calibration of
the detectors. We identify a variety of sources, such as intrinsic
contaminations due to primordial radioisotopes and cosmogenic activation of the
target material. In particular, we detect a 3.6keV X-ray line from the decay of
41-Ca with an activity of (26\pm4)\mu Bq, corresponding to a ratio
41-Ca/40-Ca=(2.2\pm0.3)\times10^{-16}.
[23]
oai:arXiv.org:0903.4687 [pdf] - 22801
Discrimination of Recoil Backgrounds in Scintillating Calorimeters
Lang, R. F.;
Angloher, G.;
Bauer, M.;
Bavykina, I.;
Bento, A.;
Brown, A.;
Bucci, C.;
Ciemniak, C.;
Coppi, C.;
Deuter, G.;
von Feilitzsch, F.;
Hauff, D.;
Henry, S.;
Huff, P.;
Imber, J.;
Ingleby, S.;
Isaila, C.;
Jochum, J.;
Kiefer, M.;
Kimmerle, M.;
Kraus, H.;
Lanfranchi, J. -C.;
Malek, M.;
McGowan, R.;
Mikhailik, V. B.;
Pantic, E.;
Petricca, F.;
Pfister, S.;
Potzel, W.;
Pröbst, F.;
Roth, S.;
Rottler, K.;
Sailer, C.;
Schäffner, K.;
Schmaler, J.;
Scholl, S.;
Seidel, W.;
Stodolsky, L.;
Tolhurst, A. J. B.;
Usherov, I.;
Westphal, W.
Submitted: 2009-03-26
The alpha decay of $\n{{}^{210}Po}$ is a dangerous background to rare event
searches. Here, we describe observations related to this alpha decay in the
Cryogenic Rare Event Search with Superconducting Thermometers (CRESST). We find
that lead nuclei show a scintillation light yield in our $\n{CaWO_4}$ crystals
of $0.0142\pm0.0013$ relative to electrons of the same energy. We describe a
way to discriminate this source of nuclear recoil background by means of a
scintillating foil, and demonstrate its effectiveness. This leads to an
observable difference in the pulse shape of the light detector, which can be
used to tag these events. Differences in pulse shape of the phonon detector
between lead and electron recoils are also extracted, opening the window to
future additional background suppression techniques based on pulse shape
discrimination in such experiments.
[24]
oai:arXiv.org:0809.1829 [pdf] - 16181
Commissioning Run of the CRESST-II Dark Matter Search
Angloher, G.;
Bauer, M.;
Bavykina, I.;
Bento, A.;
Brown, A.;
Bucci, C.;
Ciemniak, C.;
Coppi, C.;
Deuter, G.;
von Feilitzsch, F.;
Hauff, D.;
Henry, S.;
Huff, P.;
Imber, J.;
Ingleby, S.;
Isaila, C.;
Jochum, J.;
Kiefer, M.;
Kimmerle, M.;
Kraus, H.;
Lanfranchi, J. -C.;
Lang, R. F.;
Majorovits, B.;
Malek, M.;
McGowan, R.;
Mikhailik, V. B.;
Pantic, E.;
Petricca, F.;
Pfister, S.;
Potzel, W.;
Proebst, F.;
Rau, W.;
Roth, S.;
Rottler, K.;
Sailer, C.;
Schaeffner, K.;
Schmaler, J.;
Scholl, S.;
Seidel, W.;
Stodolsky, L.;
Tolhurst, A. J. B.;
Usherov, I.;
Westphal, W.
Submitted: 2008-09-10, last modified: 2009-02-16
The CRESST cryogenic direct dark matter search at Gran Sasso, searching for
WIMPs via nuclear recoil, has been upgraded to CRESST-II by several changes and
improvements.We present the results of a commissioning run carried out in 2007.
The basic element of CRESST-II is a detector module consisting of a large (~
300 g) CaWO_4 crystal and a very sensitive smaller (~ 2 g) light detector to
detect the scintillation light from the CaWO_4.Information from light-quenching
factor studies allows the definition of a region of the energy-light yield
plane which corresponds to tungsten recoils. A neutron test is reported which
supports the principle of using the light yield to identify the recoiling
nucleus.
Data obtained with two detector modules for a total exposure of 48 kg-days
are presented. Judging by the rate of events in the "all nuclear recoils"
acceptance region the apparatus shows a factor ~ten improvement with respect to
previous results, which we attribute principally to the presence of the neutron
shield.
In the "tungsten recoils" acceptance region three events are found,
corresponding to a rate of 0.063 per kg-day. Standard assumptions on the dark
matter flux, coherent or spin independent interactions,then yield a limit for
WIMP-nucleon scattering of 4.8 \times 10^{-7}pb, at M{WIMP} ~50 GeV.
[25]
oai:arXiv.org:0809.4975 [pdf] - 16840
Glued CaWO4 Detectors for the CRESST-II Experiment
Submitted: 2008-09-29, last modified: 2008-10-21
The Cryogenic Rare Event Search with Superconducting Thermometers Phase II
(CRESST-II) at the L.N.G.S in Italy is searching for Dark Matter using
low-temperature calorimeters. These detectors allow to discriminate different
particles by simultaneous measurement of phonons and scintillation light. The
sensors used consist of superconducting tungsten thin-film thermometers, which
measure the thermal effect of the phonons created in an attached absorber
crystal. It has been observed that the scintillation of the CaWO4 absorber
degrades during the process of depositing the tungsten film. In order to
prevent this, a new technique for producing the detectors was investigated.
This technique might also be valuable by expanding the range of scintillator
materials suitable for producing a Dark Matter detector.
[26]
oai:arXiv.org:astro-ph/0512120 [pdf] - 78320
Critical revision of the ZEPLIN-I sensitivity to WIMP interactions
Benoit, A.;
Chapellier, M.;
Chardin, G.;
Dumoulin, L.;
Eitel, K.;
Gascon, J.;
Gerbier, G.;
Goldbach, C.;
Jochum, J.;
de Lesquen, A.;
Nollez, G.;
Proebst, F.;
Seidel, W.
Submitted: 2005-12-05, last modified: 2006-04-19
The ZEPLIN collaboration has recently published its first result presenting a
maximum sensitivity of $1.1 \times 10^{-6}$ picobarn for a WIMP mass of
$\approx$ 60 GeV. The analysis is based on a discrimination method using the
different time distribution of scintillation light generated in electron recoil
and nuclear recoil interactions. We show that the methodology followed both for
the calibration of the ZEPLIN-I detector response and for the estimation of the
discrimination power is not reliable enough to claim any background
discrimination at the present stage. The ZEPLIN-I sensitivity appears then to
be in the order of 10$^{-3}$ picobarn, three orders of magnitude above the
claimed 1.1 10$^{-6}$ picobarn.
[27]
oai:arXiv.org:astro-ph/0604094 [pdf] - 81163
New Technique for the Measurement of the Scintillation Efficiency of
Nuclear Recoils
Submitted: 2006-04-05
We present a new technique developed for the measurement of the scintillation
efficiency of nuclear recoils in solid scintillators. Using this technique we
measured the quenching of the scintillation efficiency for the various
recoiling nuclei in CaWO4 crystals which are used in direct Dark Matter
searches.
[28]
oai:arXiv.org:physics/0504151 [pdf] - 119090
Fracture Processes Observed with A Cryogenic Detector
Astrom, J.;
Di Stefano, P. C. F.;
Proebst, F.;
Stodolsky, L.;
Timonen, J.;
Bucci, C.;
Cooper, S.;
Cozzini, C.;
Feilitzsch, F. v.;
Kraus, H.;
Marchese, J.;
Meier, O.;
Nagel, U.;
Ramachers, Y.;
Seidel, W.;
Sisti, M.;
Uchaikin, S.;
Zerle, L.
Submitted: 2005-04-21, last modified: 2006-03-21
In the early stages of running of the CRESST dark matter search using
sapphire detectors at very low temperature, an unexpectedly high rate of signal
pulses appeared. Their origin was finally traced to fracture events in the
sapphire due to the very tight clamping of the detectors. During extensive runs
the energy and time of each event was recorded, providing large data sets for
such phenomena. We believe this is the first time the energy release in
fracture has been directly and accurately measured on a microscopic
event-by-event basis. The energy threshold corresponds to the breaking of only
a few hundred covalent bonds, a sensitivity some orders of magnitude greater
than that of previous technique.
We report some features of the data, including energy distributions, waiting
time distributions, autocorrelations and the Hurst exponent. The energy
distribution appear to follow a power law, $dN/dE\propto E^{-\beta}$, similar
to the power law for earthquake magnitudes, and after appropriate translation,
with a similar exponent. In the time domain,the waiting time $w$ or gap
distribution between events has a power law behavior at small $w$ and an
exponential fall-off at large $w,$ and can be fit $\propto
w^{-\alpha}e^{-w/w_0}$. The autocorrelation function shows time correlations
lasting for substantial parts of an hour. An asymmetry is found around large
events, with higher count rates after, as opposed to before,the large event .
[29]
oai:arXiv.org:astro-ph/0408006 [pdf] - 66497
Limits on WIMP dark matter using scintillating CaWO4 cryogenic detectors
with active background suppression
Angloher, G.;
Bucci, C.;
Christ, P.;
Cozzini, C.;
von Feilitzsch, F.;
Hauff, D.;
Henry, S.;
Jagemann, Th.;
Jochum, J.;
Kraus, H.;
Majorovits, B.;
Ninkovic, J.;
Petricca, F.;
Potzel, W.;
Pröbst, F.;
Ramachers, Y.;
Razeti, M.;
Rau, W.;
Seidel, W.;
Stark, M.;
Stodolsky, L.;
Tolhurst, A. J. B.;
Westphal, W.;
Wulandari, H.
Submitted: 2004-07-30, last modified: 2005-01-17
We present first significant limits on WIMP dark matter by the phonon-light
technique, where combined phonon and light signals from a scintillating
cryogenic detector are used. Data from early 2004 with two 300 g CRESST-II
prototype detector modules are presented, with a net exposure of 20.5 kg days.
The modules consist of a CaWO4 scintillating ``target'' crystal and a smaller
cryogenic light detector. The combination of phonon and light signals leads to
a strong suppression of non-nuclear recoil backgrounds. Using this information
to define an acceptance region for nuclear recoils we have 16 events from the
two modules, corresponding to a rate for nuclear recoils between 12 and 40 keV
of (0.87 +- 0.22) events/(kg day). This is compatible with the rate expected
from neutron background, and most of these events lie in the region of the
phonon-light plane anticipated for neutron-induced recoils. A particularly
strong limit for WIMPs with coherent scattering results from selecting a region
of the phonon-light plane corresponding to tungsten recoils, where the best
module shows zero events.
[30]
oai:arXiv.org:astro-ph/0411396 [pdf] - 1507893
The CRESST Dark Matter Search
Majorovits, B.;
Angloher, G.;
Bucci, C.;
Christ, P.;
Cozzini, C.;
von Feilitzsch, F.;
Hauff, D.;
Henry, S.;
Jagemann, Th.;
Jochum, J.;
Kraus, H.;
Mikhailik, V.;
Ninkovic, J.;
Petricca, F.;
Potzel, W.;
Proebst, F.;
Ramachers, Y.;
Razeti, M.;
Rau, W.;
Seidel, W.;
Stark, M.;
Stodolsky, L.;
Tolhurst, A. J. B.;
Wahl, D.;
Westphal, W.;
Wulandari, H.
Submitted: 2004-11-15
We present first competitive results on WIMP dark matter using the
phonon-light-detection technique. A particularly strong limit for WIMPs with
coherent scattering results from selecting a region of the phonon-light plane
corresponding to tungsten recoils. The observed count rate in the neutron band
is compatible with the rate expected from neutron background. CRESST is
presently being upgraded with a 66 channel SQUID readout system, a neutron
shield and a muon veto system. This results in a significant improvement in
sensitivity.
[31]
oai:arXiv.org:astro-ph/0310707 [pdf] - 60370
Direct Dark Matter Searches
Submitted: 2003-10-24
The elucidation of the nature of dark matter is one of the challenging tasks
in astroparticle physics. A brief overview on the different methods to search
directly for dark matter in form of Weakly Interacting Massive Particles
(WIMPs) is given.
[32]
oai:arXiv.org:astro-ph/0106314 [pdf] - 43110
Results and plans of the CRESST dark matter search
Altmann, M.;
Angloher, G.;
Bruckmayer, M.;
Bucci, C.;
Cooper, S.;
Cozzini, C.;
DiStefano, P.;
von Feilitzsch, F.;
Frank, T.;
Hauff, D.;
Jagemann, Th.;
Jochum, J.;
Keeling, R.;
Kraus, H.;
Macallister, J.;
Proebst, F.;
Ramachers, Y.;
Schnagl, J.;
Seidel, W.;
Sergeyev, I.;
Stark, M.;
Stodolsky, L.;
Wulandari, H.
Submitted: 2001-06-18
Data taken by CRESST in 2000 with a cryogenic detector system based on 262 g
sapphire crystals is used to place limits on WIMP dark matter in the Galactic
Halo. The detector is especially sensitive for low-mass WIMPS with
spin-dependent cross sections and improves on existing limits in this region.
CRESST is now preparing for a second phase, which will use a 10 kg detector
consisting of 300 g CaWO4 crystals with simultaneous detection of phonons and
scintillation light to reduce background.