Normalized to: Segui, L.
[1]
oai:arXiv.org:1211.4508 [pdf] - 1157898
Ionization and scintillation response of high-pressure xenon gas to
alpha particles
NEXT Collaboration;
Álvarez, V.;
Borges, F. I. G. M.;
Cárcel, S.;
Cebrián, S.;
Cervera, A.;
Conde, C. A. N.;
Dafni, T.;
Díaz, J.;
Egorov, M.;
Esteve, R.;
Evtoukhovitch, P.;
Fernandes, L. M. P.;
Ferrario, P.;
Ferreira, A. L.;
Freitas, E. D. C.;
Gehman, V. M.;
Gil, A.;
Goldschmidt, A.;
Gómez, H.;
Gómez-Cadenas, J. J.;
González-Díaz, D.;
Gutiérrez, R. M.;
Hauptman, J.;
Morata, J. A. Hernando;
Herrera, D. C.;
Irastorza, I. G.;
Jinete, M. A.;
Labarga, L.;
Laing, A.;
Liubarsky, I.;
Lopes, J. A. M.;
Lorca, D.;
Losada, M.;
Luzón, G.;
Marí, A.;
Martín-Albo, J.;
Miller, T.;
Moiseenko, A.;
Monrabal, F.;
Monteiro, C. M. B.;
Mora, F. J.;
Moutinho, L. M.;
Vidal, J. Muñoz;
da Luz, H. Natal;
Navarro, G.;
Nebot-Guinot, M.;
Nygren, D.;
Oliveira, C. A. B.;
Palma, R.;
Pérez, J.;
Aparicio, J. L. Pérez;
Renner, J.;
Ripoll, L.;
Rodríguez, A.;
Rodríguez, J.;
Santos, F. P.;
Santos, J. M. F. dos;
Segui, L.;
Serra, L.;
Shuman, D.;
Simón, A.;
Sofka, C.;
Sorel, M.;
Toledo, J. F.;
Tomás, A.;
Torrent, J.;
Tsamalaidze, Z.;
Vázquez, D.;
Veloso, J. F. C. A.;
Webb, R.;
White, J. T;
Yahlali, N.
Submitted: 2012-11-19, last modified: 2013-05-21
High-pressure xenon gas is an attractive detection medium for a variety of
applications in fundamental and applied physics. In this paper we study the
ionization and scintillation detection properties of xenon gas at 10 bar
pressure. For this purpose, we use a source of alpha particles in the NEXT-DEMO
time projection chamber, the large scale prototype of the NEXT-100 neutrinoless
double beta decay experiment, in three different drift electric field
configurations. We measure the ionization electron drift velocity and
longitudinal diffusion, and compare our results to expectations based on
available electron scattering cross sections on pure xenon. In addition, two
types of measurements addressing the connection between the ionization and
scintillation yields are performed. On the one hand we observe, for the first
time in xenon gas, large event-by-event correlated fluctuations between the
ionization and scintillation signals, similar to that already observed in
liquid xenon. On the other hand, we study the field dependence of the average
scintillation and ionization yields. Both types of measurements may shed light
on the mechanism of electron-ion recombination in xenon gas for highly-ionizing
particles. Finally, by comparing the response of alpha particles and electrons
in NEXT-DEMO, we find no evidence for quenching of the primary scintillation
light produced by alpha particles in the xenon gas.
[2]
oai:arXiv.org:1210.3287 [pdf] - 1152052
Micromegas-TPC operation at high pressure in xenon-trimethylamine
mixtures
Cebrián, S.;
Dafni, T.;
Ferrer-Ribas, E.;
Giomataris, I.;
Gonzalez-Diaz, D.;
Gómez, H.;
Herrera, D. C.;
Iguaz, F. J.;
Irastorza, I. G.;
Luzon, G.;
Rodríguez, A.;
Segui, L.;
Tomás, A.
Submitted: 2012-10-11, last modified: 2012-11-23
In this work we present a systematic study of Micromegas detectors in high
pressure gaseous Xenon using trimethylamine (TMA) as quencher gas. Gas gains
and energy resolutions for 22.1 keV X-rays are measured for pressures between 1
and 10 bar and various relative concentrations of TMA from 0.3 % to 15 %. We
observe stable operation at all pressures, and a strongly enhanced gas gain,
suggestive of Penning-like energy-transfer processes. The effect is present at
all pressures and it is strongest at TMA concentrations ranging from 1.5 % to 3
%. Operating in this concentration range, the maximum gain reached values as
high as x10^3 (x10^2) at 1 (10) bar. Besides, the energy resolution achievable
for 22.1 keV X-rays is substantially better than the one previously obtained in
pure Xe, going down to 7.3 % (9.6 %) FWHM for 1 (10) bar. These results are of
interest for calorimetric applications of high pressure gas Xe TPCs, in
particular for the search of the neutrinoless double beta decay of Xe-136. The
resolutions achieved would extrapolate into 0.7 % (0.9 %) FWHM at the Qbb value
of Xe-136 for 1 (10) bar.
[3]
oai:arXiv.org:1110.2608 [pdf] - 1084811
Low X-ray bakground measurements at the Underground Canfranc Laboratory
Galan, J.;
Aune, S.;
Dafni, T.;
Fanourakis, G.;
Ferrer-Ribas, E.;
Garcia, J. A.;
Gardikiotis, A.;
Geralis, T.;
Giomataris, I.;
Gomez, H.;
Garza, J. G.;
Herrera, D. C.;
Iguaz, F. J.;
Irastorza, I. G.;
Luzon, G.;
Papaevangelou, T.;
Rodriguez, A.;
Ruz, J.;
Segui, L.;
Tomas, A.;
Vafeiadis, T.;
Yildiz, S. C.
Submitted: 2011-10-12, last modified: 2011-10-25
Micromegas detectors, thanks to the good spatial and temporal discrimination
capabilities, are good candidates for rare event search experiments. Recent
X-ray background levels achieved by these detectors in the CAST experiment have
motivated further studies in the nature of the background levels measured. In
particular, different shielding configurations have been tested at the Canfranc
Underground Laboratory, using a microbulk type detector which was previously
running at the CAST experiment. The first results underground show that this
technology, which is made of low radiative materials, is able to reach
background levels up to $2 \times 10^{-7}$keV$^{-1}$s$^{-1}$cm$^{-2}$ with a
proper shielding. Moreover, the experimental background measurements are
complemented with Geant4 simulations which allow to understand the origin of
the background, and to optimize future shielding set-ups.