Normalized to: Scorza, S.
[1]
oai:arXiv.org:2005.14067 [pdf] - 2103535
Constraints on low-mass, relic dark matter candidates from a
surface-operated SuperCDMS single-charge sensitive detector
SuperCDMS Collaboration;
Amaral, D. W.;
Aralis, T.;
Aramaki, T.;
Arnquist, I. J.;
Azadbakht, E.;
Banik, S.;
Barker, D.;
Bathurst, C.;
Bauer, D. A.;
Bezerra, L. V. S.;
Bhattacharyya, R.;
Binder, T.;
Bowles, M. A.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Calkins, R.;
Cameron, R. A.;
Cartaro, C.;
Cerdeño, D. G.;
Chang, Y. -Y.;
Chen, R.;
Chott, N.;
Cooley, J.;
Coombes, H.;
Corbett, J.;
Cushman, P.;
De Brienne, F.;
di Vacri, M. L.;
Diamond, M. D.;
Fascione, E.;
Figueroa-Feliciano, E.;
Fink, C. W.;
Fouts, K.;
Fritts, M.;
Gerbier, G.;
Germond, R.;
Ghaith, M.;
Golwala, S. R.;
Harris, H. R.;
Herbert, N.;
Hines, B. A.;
Hollister, M. I.;
Hong, Z.;
Hoppe, E. W.;
Hsu, L.;
Huber, M. E.;
Iyer, V.;
Jardin, D.;
Jastram, A.;
Kelsey, M. H.;
Kubik, A.;
Kurinsky, N. A.;
Lawrence, R. E.;
Li, A.;
Loer, B.;
Asamar, E. Lopez;
Lukens, P.;
MacDonell, D.;
MacFarlane, D. B.;
Mahapatra, R.;
Mandic, V.;
Mast, N.;
Mayer, A. J.;
Michaud, É. M.;
Michielin, E.;
Mirabolfathi, N.;
Mohanty, B.;
Mendoza, J. D. Morales;
Nagorny, S.;
Nelson, J.;
Neog, H.;
Novati, V.;
Orrell, J. L.;
Oser, S. M.;
Page, W. A.;
Pakarha, P.;
Partridge, R.;
Podviianiuk, R.;
Ponce, F.;
Poudel, S.;
Pyle, M.;
Rau, W.;
Reid, E.;
Ren, R.;
Reynolds, T.;
Roberts, A.;
Robinson, A. E.;
Rogers, H. E.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Sattari, A.;
Schnee, R. W.;
Scorza, S.;
Serfass, B.;
Sincavage, D. J.;
Stanford, C.;
Stein, M.;
Street, J.;
Toback, D.;
Underwood, R.;
Verma, S.;
Villano, A. N.;
von Krosigk, B.;
Watkins, S. L.;
Wills, L.;
Wilson, J. S.;
Wilson, M. J.;
Winchell, J.;
Wright, D. H.;
Yellin, S.;
Young, B. A.;
Yu, T. C.;
Zhang, E.;
Zhang, H. G.;
Zhao, X.;
Zheng, L.
Submitted: 2020-05-28
This article presents an analysis and the resulting limits on light dark
matter inelastically scattering off of electrons, and on dark photon and
axion-like particle absorption, using a second-generation SuperCDMS
high-voltage eV-resolution detector. The 0.93 gram Si detector achieved a 3 eV
phonon energy resolution; for a detector bias of 100 V, this corresponds to a
charge resolution of 3% of a single electron-hole pair. The energy spectrum is
reported from a blind analysis with 1.2 gram-days of exposure acquired in an
above-ground laboratory. With charge carrier trapping and impact ionization
effects incorporated into the dark matter signal models, the dark
matter-electron cross section $\bar{\sigma}_{e}$ is constrained for dark matter
masses from 0.5--$10^{4} $MeV$/c^{2}$; in the mass range from 1.2--50
eV$/c^{2}$ the dark photon kinetic mixing parameter $\varepsilon$ and the
axioelectric coupling constant $g_{ae}$ are constrained. The minimum 90%
confidence-level upper limits within the above mentioned mass ranges are
$\bar{\sigma}_{e}\,=\,8.7\times10^{-34}$ cm$^{2}$,
$\varepsilon\,=\,3.3\times10^{-14}$, and $g_{ae}\,=\,1.0\times10^{-9}$.
[2]
oai:arXiv.org:1806.07043 [pdf] - 1944785
Production Rate Measurement of Tritium and Other Cosmogenic Isotopes in
Germanium with CDMSlite
SuperCDMS Collaboration;
Agnese, R.;
Aralis, T.;
Aramaki, T.;
Arnquist, I. J.;
Azadbakht, E.;
Baker, W.;
Barker, D.;
Bauer, D. A.;
Binder, T.;
Bowles, M. A.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Calkins, R.;
Cartaro, C.;
Cerdeño, D. G.;
Chang, Y. -Y.;
Cooley, J.;
Cornell, B.;
Cushman, P.;
Doughty, T.;
Fascione, E.;
Figueroa-Feliciano, E.;
Fink, C. W.;
Fritts, M.;
Gerbier, G.;
Germond, R.;
Ghaith, M.;
Golwal, S. R.;
Harris, H. R.;
Hong, Z.;
Hoppe, E. W.;
Hsu, L.;
Huber, M. E.;
Iyer, V.;
Jardin, D.;
Jastram, A.;
Jena, C.;
Kelsey, M. H.;
Kennedy, A.;
Kubik, A.;
Kurinsky, N. A.;
Lawrence, R. E.;
Loer, B.;
Asamar, E. Lopez;
Lukens, P.;
MacDonell, D.;
Mahapatra, R.;
Mandic, V.;
Mast, N.;
Miller, E.;
Mirabolfathi, N.;
Mohanty, B.;
Mendoza, J. D. Morales;
Nelson, J.;
Orrell, J. L.;
Oser, S. M.;
Page, W. A.;
Partridge, R.;
Pepin, M.;
Ponce, F.;
Poudel, S.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Reisetter, A.;
Ren, R.;
Reynolds, T.;
Roberts, A.;
Robinson, A. E.;
Rogers, H. E.;
Saab, T.;
Sadoulet, B.;
Banik, S.;
Sander, J.;
Scarff, A.;
Schnee, R. W.;
Scorza, S.;
Senapati, K.;
Serfass, B.;
Speller, D.;
Stein, M.;
Street, J.;
Tanaka, H. A.;
Toback, D.;
Underwood, R.;
Villano, A. N.;
von Krosigk, B.;
Watkins, S. L.;
Wilson, J. S.;
Wilson, M. J.;
Winchell, J.;
Wright, D. H.;
Yellin, S.;
Young, B. A.;
Zhang, X.;
Zhao, X.
Submitted: 2018-06-19, last modified: 2019-08-16
Future direct searches for low-mass dark matter particles with germanium
detectors, such as SuperCDMS SNOLAB, are expected to be limited by backgrounds
from radioactive isotopes activated by cosmogenic radiation inside the
germanium. There are limited experimental data available to constrain
production rates and a large spread of theoretical predictions. We examine the
calculation of expected production rates, and analyze data from the second run
of the CDMS low ionization threshold experiment (CDMSlite) to estimate the
rates for several isotopes. We model the measured CDMSlite spectrum and fit for
contributions from tritium and other isotopes. Using the knowledge of the
detector history, these results are converted to cosmogenic production rates at
sea level. The production rates in atoms/(kg$\cdot$day) are 74$\pm$9 for $^3$H,
1.5$\pm$0.7 for $^{55}$Fe, 17$\pm$5 for $^{65}$Zn, and 30$\pm$18 for $^{68}$Ge.
[3]
oai:arXiv.org:1804.10697 [pdf] - 1877835
First Dark Matter Constraints from a SuperCDMS Single-Charge Sensitive
Detector
SuperCDMS Collaboration;
Agnese, R.;
Aralis, T.;
Aramaki, T.;
Arnquist, I. J.;
Azadbakht, E.;
Baker, W.;
Banik, S.;
Barker, D.;
Bauer, D. A.;
Binder, T.;
Bowles, M. A.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Calkins, R.;
Cartaro, C.;
Cerdeno, D. G.;
Chang, Y. -Y.;
Cooley, J.;
Cornell, B.;
Cushman, P.;
Di Stefano, P. C. F.;
Doughty, T.;
Fascione, E.;
Figueroa-Feliciano, E.;
Fink, C.;
Fritts, M.;
Gerbier, G.;
Germond, R.;
Ghaith, M.;
Golwala, S. R.;
Harris, H. R.;
Hong, Z.;
Hoppe, E. W.;
Hsu, L.;
Huber, M. E.;
Iyer, V.;
Jardin, D.;
Jena, C.;
Kelsey, M. H.;
Kennedy, A.;
Kubik, A.;
Kurinsky, N. A.;
Lawrence, R. E.;
Leyva, J. V.;
Loer, B.;
Asamar, E. Lopez;
Lukens, P.;
MacDonell, D.;
Mahapatra, R.;
Mandic, V.;
Mast, N.;
Miller, E. H.;
Mirabolfathi, N.;
Mohanty, B.;
Mendoza, J. D. Morales;
Nelson, J.;
Orrell, J. L.;
Oser, S. M.;
Page, W. A.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Ponce, F.;
Poudel, S.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Reisetter, A.;
Reynolds, T.;
Roberts, A.;
Robinson, A. E.;
Rogers, H. E.;
Romani, R. K.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Scarff, A.;
Schnee, R. W.;
Scorza, S.;
Senapati, K.;
Serfass, B.;
So, J.;
Speller, D.;
Stanford, C.;
Stein, M.;
Street, J.;
Tanaka, H. A.;
Toback, D.;
Underwood, R.;
Villano, A. N.;
von Krosigk, B.;
Watkins, S. L.;
Wilson, J. S.;
Wilson, M. J.;
Winchell, J.;
Wright, D. H.;
Yellin, S.;
Young, B. A.;
Zhang, X.;
Zhao, X.
Submitted: 2018-04-27, last modified: 2019-05-03
We present the first limits on inelastic electron-scattering dark matter and
dark photon absorption using a prototype SuperCDMS detector having a charge
resolution of 0.1 electron-hole pairs (CDMS HVeV, a 0.93 gram CDMS HV device).
These electron-recoil limits significantly improve experimental constraints on
dark matter particles with masses as low as 1 MeV/$\mathrm{c^2}$. We
demonstrate a sensitivity to dark photons competitive with other leading
approaches but using substantially less exposure (0.49 gram days). These
results demonstrate the scientific potential of phonon-mediated semiconductor
detectors that are sensitive to single electronic excitations.
[4]
oai:arXiv.org:1808.09098 [pdf] - 1873743
Search for Low-Mass Dark Matter with CDMSlite Using a Profile Likelihood
Fit
SuperCDMS Collaboration;
Agnese, R.;
Aralis, T.;
Aramaki, T.;
Arnquist, I. J.;
Azadbakht, E.;
Baker, W.;
Banik, S.;
Barker, D.;
Bauer, D. A.;
Binder, T.;
Bowles, M. A.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Calkins, R.;
Cameron, R. A.;
Cartaro, C.;
Cerdeño, D. G.;
Chang, Y. -Y.;
Cooley, J.;
Cornell, B.;
Cushman, P.;
De Brienne, F.;
Doughty, T.;
Fascione, E.;
Figueroa-Feliciano, E.;
Fink, C. W.;
Fritts, M.;
Gerbier, G.;
Germond, R.;
Ghaith, M.;
Golwala, S. R.;
Harris, H. R.;
Herbert, N.;
Hong, Z.;
Hoppe, E. W.;
Hsu, L.;
Huber, M. E.;
Iyer, V.;
Jardin, D.;
Jastram, A.;
Jena, C.;
Kelsey, M. H.;
Kennedy, A.;
Kubik, A.;
Kurinsky, N. A.;
Lawrence, R. E.;
Loer, B.;
Asamar, E. Lopez;
Lukens, P.;
MacDonell, D.;
Mahapatra, R.;
Mandic, V.;
Mast, N.;
Miller, E.;
Mirabolfathi, N.;
Mohanty, B.;
Mendoza, J. D. Morales;
Nelson, J.;
Neog, H.;
Orrell, J. L.;
Oser, S. M.;
Page, W. A.;
Partridge, R.;
Pepin, M.;
Ponce, F.;
Poudel, S.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Reisetter, A.;
Ren, R.;
Reynolds, T.;
Roberts, A.;
Robinson, A. E.;
Rogers, H. E.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Scarff, A.;
Schnee, R. W.;
Scorza, S.;
Senapati, K.;
Serfass, B.;
Speller, D.;
Stanford, C.;
Stein, M.;
Street, J.;
Tanaka, H. A.;
Toback, D.;
Underwood, R.;
Villano, A. N.;
von Krosigk, B.;
Watkins, S. L.;
Wilson, J. S.;
Wilson, M. J.;
Winchell, J.;
Wright, D. H.;
Yellin, S.;
Young, B. A.;
Zhang, X.;
Zhao, X.
Submitted: 2018-08-27, last modified: 2019-04-25
The Cryogenic Dark Matter Search low ionization threshold experiment
(CDMSlite) searches for interactions between dark matter particles and
germanium nuclei in cryogenic detectors. The experiment has achieved a low
energy threshold with improved sensitivity to low-mass (<10 GeV/c$^2$) dark
matter particles. We present an analysis of the final CDMSlite data set, taken
with a different detector than was used for the two previous CDMSlite data
sets. This analysis includes a data "salting" method to protect against bias,
improved noise discrimination, background modeling, and the use of profile
likelihood methods to search for a dark matter signal in the presence of
backgrounds. We achieve an energy threshold of 70 eV and significantly improve
the sensitivity for dark matter particles with masses between 2.5 and 10
GeV/c$^2$ compared to previous analyses. We set an upper limit on the dark
matter-nucleon scattering cross section in germanium of 5.4$\times$10$^{-42}$
cm$^2$ at 5 GeV/c$^2$, a factor of $\sim$2.5 improvement over the previous
CDMSlite result.
[5]
oai:arXiv.org:1805.09942 [pdf] - 1867949
Energy Loss Due to Defect Formation from $^{206}$Pb Recoils in SuperCDMS
Germanium Detectors
Agnese, Robert;
Aralis, Taylor;
Aramaki, Tsuguo;
Arnquist, Isaac;
Azadbakht, Elham;
Baker, William;
Banik, Samir;
Barker, D'Ann;
Bauer, Dan;
Binder, Thomas;
Bowles, Michael;
Brink, Paul;
Bunker, Ray;
Cabrera, Blas;
Calkins, Robert;
Cartaro, Concetta;
Cerdeno, David;
Chang, Yen-Yung;
Cooley, Jodi;
Cornell, Brett;
Cushman, Priscilla;
Di Stefano, Philippe;
Doughty, Todd;
Fascione, Eleanor;
Figueroa, Tali;
Fink, Caleb;
Fritts, Matt;
Gerbier, Gilles;
Germond, Richard;
Ghaith, Muad;
Golwala, Sunil;
Harris, Rusty;
Hong, Ziqing;
Hoppe, Eric;
Hsu, Lauren;
Huber, Martin;
Iyer, Vijay;
Jardin, Dan;
Jena, Chitrasen;
Kelsey, Michael;
Kennedy, Allison;
Kubik, Andrew;
Kurinsky, Noah;
Lawrence, Richard;
Loer, Ben;
Lopez-Asamar, Elias;
Lukens, Pat;
MacDonell, Danika;
Mahapatra, Rupak;
Mandic, Vuk;
Mast, Nicholas;
Miller, Eric;
Mirabolfathi, Nader;
Mohanty, Bedangadas;
Morales, Jorge;
Nelson, Jack;
Orrell, John;
Oser, Scott;
Page, William;
Partridge, Richard;
Pepin, Mark;
Ponce, Francisco;
Poudel, Sudip;
Pyle, Matt;
Qiu, Hang;
Rau, Wolfgang;
Reisetter, Angela;
Ren, Tom;
Reynolds, Tyler;
Roberts, Amy;
Robinson, Alan;
Rogers, Hannah;
Saab, Tarek;
Sadoulet, Bernard;
Sander, Joel;
Scarff, Andrew;
Schnee, Richard;
Scorza, Silvia;
Senapati, Kartik;
Serfass, Bruno;
Speller, Danielle;
Stein, Matthew;
Street, Joseph;
Tanaka, Hirohisa;
Toback, David;
Underwood, Ryan;
Villano, Anthony;
von Krosigk, Belina;
Watkins, Samuel;
Wilson, Jon;
Wilson, Matthew;
Winchell, Joshua;
Wright, Dennis;
Yellin, Steve;
Young, Betty;
Zhang, Xiaohe;
Zhao, Xuji
Submitted: 2018-05-24, last modified: 2019-04-16
The Super Cryogenic Dark Matter Search experiment (SuperCDMS) at the Soudan
Underground Laboratory studied energy loss associated with Frenkel defect
formation in germanium crystals at mK temperatures using in situ $^{210}$Pb
sources. We examine the spectrum of $^{206}$Pb nuclear recoils near its
expected 103 keV endpoint energy and determine an energy loss of
$\left(6.08\pm0.18\right)$ %, which we attribute to defect formation. From this
result and using TRIM simulations, we extract the first experimentally
determined average displacement threshold energy of
$\left(19.7^{+0.6}_{-0.5}\right)$ eV for germanium. This has implications for
the analysis thresholds of future germanium-based dark matter searches.
[6]
oai:arXiv.org:1803.02903 [pdf] - 1724039
Nuclear-recoil energy scale in CDMS II silicon dark-matter detectors
Agnese, R.;
Anderson, A. J.;
Aramaki, T.;
Baker, W.;
Balakishiyeva, D.;
Banik, S.;
Barker, D.;
Thakur, R. Basu;
Bauer, D. A.;
Binder, T.;
Borgland, A.;
Bowles, M. A.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Calkins, R.;
Cartaro, C.;
Cerdeno, D. G.;
Chagani, H.;
Chang, Y. -Y.;
Chen, Y.;
Cooley, J.;
Cornell, B.;
Cushman, P.;
Daal, M.;
Doughty, T.;
Dragowsky, E. M.;
Esteban, L.;
Fallows, S.;
Fascione, E.;
Figueroa-Feliciano, E.;
Fritts, M.;
Gerbier, G.;
Germond, R.;
Ghaith, M.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Harris, H. R.;
Holmgren, D.;
Hong, Z.;
Hsu, L.;
Huber, M. E.;
Iyer, V.;
Jardin, D.;
Jastram, A.;
Jena, C.;
Kelsey, M. H.;
Kennedy, A.;
Kubik, A.;
Kurinsky, N. A.;
Leder, A.;
Asamar, E. Lopez;
Lukens, P.;
MacDonell, D.;
Mahapatra, R.;
Mandic, V.;
Mast, N.;
McCarthy, K. A.;
Miller, E. H.;
Mirabolfathi, N.;
Moffatt, R. A.;
Mohanty, B.;
Moore, D.;
Mendoza, J. D. Morales;
Nelson, J.;
Oser, S. M.;
Page, K.;
Page, W. A.;
Partridge, R.;
Martinez, M. Penalver;
Pepin, M.;
Phipps, A.;
Poudel, S.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Roberts, A.;
Rogers, H. E.;
Robinson, A. E.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schneck, K.;
Schnee, R. W.;
Scorza, S.;
Senapati, K.;
Serfass, B.;
Speller, D.;
Di Stefano, P. C. F.;
Stein, M.;
Street, J.;
Tanaka, H. A.;
Toback, D.;
Underwood, R.;
Villano, A. N.;
von Krosigk, B.;
Welliver, B.;
Wilson, J. S.;
Wilson, M. J.;
Wright, D. H.;
Yellin, S.;
Yen, J. J.;
Young, B. A.;
Zhang, X.;
Zhao, X.
Submitted: 2018-03-07, last modified: 2018-07-27
The Cryogenic Dark Matter Search (CDMS II) experiment aims to detect dark
matter particles that elastically scatter from nuclei in semiconductor
detectors. The resulting nuclear-recoil energy depositions are detected by
ionization and phonon sensors. Neutrons produce a similar spectrum of
low-energy nuclear recoils in such detectors, while most other backgrounds
produce electron recoils. The absolute energy scale for nuclear recoils is
necessary to interpret results correctly. The energy scale can be determined in
CDMS II silicon detectors using neutrons incident from a broad-spectrum
$^{252}$Cf source, taking advantage of a prominent resonance in the neutron
elastic scattering cross section of silicon at a recoil (neutron) energy near
20 (182) keV. Results indicate that the phonon collection efficiency for
nuclear recoils is $4.8^{+0.7}_{-0.9}$% lower than for electron recoils of the
same energy. Comparisons of the ionization signals for nuclear recoils to those
measured previously by other groups at higher electric fields indicate that the
ionization collection efficiency for CDMS II silicon detectors operated at
$\sim$4 V/cm is consistent with 100% for nuclear recoils below 20 keV and
gradually decreases for larger energies to $\sim$75% at 100 keV. The impact of
these measurements on previously published CDMS II silicon results is small.
[7]
oai:arXiv.org:1707.01632 [pdf] - 1622232
Low-Mass Dark Matter Search with CDMSlite
SuperCDMS Collaboration;
Agnese, R.;
Anderson, A. J.;
Aralis, T.;
Aramaki, T.;
Arnquist, I. J.;
Baker, W.;
Balakishiyeva, D.;
Barker, D.;
Thakur, R. Basu;
Bauer, D. A.;
Binder, T.;
Bowles, M. A.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Calkins, R.;
Cartaro, C.;
Cerdeno, D. G.;
Chang, Y.;
Chagani, H.;
Chen, Y.;
Cooley, J.;
Cornell, B.;
Cushman, P.;
Daal, M.;
Di Stefano, P. C. F.;
Doughty, T.;
Esteban, L.;
Fascione, E.;
Figueroa-Feliciano, E.;
Fritts, M.;
Gerbier, G.;
Ghaith, M.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Harris, H. R.;
Hong, Z.;
Hoppe, E. W.;
Hsu, L.;
Huber, M. E.;
Iyer, V.;
Jardin, D.;
Jastram, A.;
Jena, C.;
Kelsey, M. H.;
Kennedy, A.;
Kubik, A.;
Kurinsky, N. A.;
Leder, A.;
Loer, B.;
Asamar, E. Lopez;
Lukens, P.;
MacDonell, D.;
Mahapatra, R.;
Mandic, V.;
Mast, N.;
Miller, E. H.;
Mirabolfathi, N.;
Moffatt, R. A.;
Mohanty, B.;
Mendoza, J. D. Morales;
Nelson, J.;
Orrell, J. L.;
Oser, S. M.;
Page, K.;
Page, W. A.;
Partridge, R.;
Pepin, M.;
Martinez, M. Penalver;
Phipps, A.;
Poudel, S.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Reynolds, T.;
Roberts, A.;
Robinson, A. E.;
Rogers, H. E.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schneck, K.;
Schnee, R. W.;
Scorza, S.;
Senapati, K.;
Serfass, B.;
Speller, D.;
Stein, M.;
Street, J.;
Tanaka, H. A.;
Toback, D.;
Underwood, R.;
Villano, A. N.;
von Krosigk, B.;
Welliver, B.;
Wilson, J. S.;
Wilson, M. J;
Wright, D. H.;
Yellin, S.;
Yen, J. J.;
Young, B. A.;
Zhang, X.;
Zhao, X.
Submitted: 2017-07-06, last modified: 2018-01-18
The SuperCDMS experiment is designed to directly detect weakly interacting
massive particles (WIMPs) that may constitute the dark matter in our Galaxy.
During its operation at the Soudan Underground Laboratory, germanium detectors
were run in the CDMSlite mode to gather data sets with sensitivity specifically
for WIMPs with masses ${<}$10 GeV/$c^2$. In this mode, a higher detector-bias
voltage is applied to amplify the phonon signals produced by drifting charges.
This paper presents studies of the experimental noise and its effect on the
achievable energy threshold, which is demonstrated to be as low as 56
eV$_{\text{ee}}$ (electron equivalent energy). The detector-biasing
configuration is described in detail, with analysis corrections for voltage
variations to the level of a few percent. Detailed studies of the
electric-field geometry, and the resulting successful development of a fiducial
parameter, eliminate poorly measured events, yielding an energy resolution
ranging from ${\sim}$9 eV$_{\text{ee}}$ at 0 keV to 101 eV$_{\text{ee}}$ at
${\sim}$10 eV$_{\text{ee}}$. New results are derived for astrophysical
uncertainties relevant to the WIMP-search limits, specifically examining how
they are affected by variations in the most probable WIMP velocity and the
Galactic escape velocity. These variations become more important for WIMP
masses below 10 GeV/$c^2$. Finally, new limits on spin-dependent low-mass
WIMP-nucleon interactions are derived, with new parameter space excluded for
WIMP masses $\lesssim$3 GeV/$c^2$
[8]
oai:arXiv.org:1708.09476 [pdf] - 1587717
Radon Daughter Plate-out Measurements at SNOLAB for Polyethylene and
Copper
Submitted: 2017-08-30, last modified: 2017-11-13
Polyethylene and copper samples were exposed to the underground air at SNOLAB
for approximately three months while several environmental factors were
monitored. Predictions of the radon-daughter plate-out rate are compared to the
resulting surface activities, obtained from high-sensitivity measurements of
alpha emissivity using the XIA UltraLo-1800 spectrometer at SMU. From these
measurements, we determine an average $^{210}$Pb plate-out rate of 249 and 423
atoms/day/cm$^{2}$ for polyethylene and copper, respectively, when exposed to
radon activity of 135 Bq/m$^{3}$ at SNOLAB. A time-dependent model of alpha
activity is discussed for these materials placed in similar environmental
conditions.
[9]
oai:arXiv.org:1707.04308 [pdf] - 1622237
Optimizing EDELWEISS detectors for low-mass WIMP searches
EDELWEISS Collaboration;
Arnaud, Q.;
Armengaud, E.;
Augier, C.;
Benoît, A.;
Bergé, L.;
Billard, J.;
Broniatowski, A.;
Camus, P.;
Cazes, A.;
Chapellier, M.;
Charlieux, F.;
De Jésus, M.;
Dumoulin, L.;
Eitel, K.;
Foerster, N.;
Gascon, J.;
Giuliani, A.;
Gros, M.;
Hehn, L.;
Jin, Y.;
Juillard, A.;
Kleifges, M.;
Kozlov, V.;
Kraus, H.;
Kudryavtsev, V. A.;
Le-Sueur, H.;
Maisonobe, R.;
Marnieros, S.;
Navick, X. -F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Poda, D.;
Queguiner, E.;
Rozov, S.;
Sanglard, V.;
Scorza, S.;
Siebenborn, B.;
Vagneron, L.;
Weber, M.;
Yakushev, E.
Submitted: 2017-07-11
The physics potential of EDELWEISS detectors for the search of low-mass
Weakly Interacting Massive Particles (WIMPs) is studied. Using a data-driven
background model, projected exclusion limits are computed using frequentist and
multivariate analysis approaches, namely profile likelihood and boosted
decision tree. Both current and achievable experimental performance are
considered. The optimal strategy for detector optimization depends critically
on whether the emphasis is put on WIMP masses below or above $\sim$ 5
GeV/c$^2$. The projected sensitivity for the next phase of the EDELWEISS-III
experiment at the Modane Underground Laboratory (LSM) for low-mass WIMP search
is presented. By 2018 an upper limit on the spin-independent WIMP-nucleon
cross-section of $\sigma_{SI} = 7 \times 10^{-42}$ cm$^2$ is expected for a
WIMP mass in the range 2$-$5 GeV/c$^2$. The requirements for a future
hundred-kilogram scale experiment designed to reach the bounds imposed by the
coherent scattering of solar neutrinos are also described. By improving the
ionization resolution down to 50 eV$_{ee}$, we show that such an experiment
installed in an even lower background environment (e.g. at SNOLAB) should allow
to observe about 80 $^8$B neutrino events after discrimination.
[10]
oai:arXiv.org:1706.01070 [pdf] - 1584219
Performance of the EDELWEISS-III experiment for direct dark matter
searches
Armengaud, E.;
Arnaud, Q.;
Augier, C.;
Benoît, A.;
Bergé, L.;
Bergmann, T.;
Billard, J.;
de Boissière, T.;
Bres, G.;
Broniatowski, A.;
Brudanin, V.;
Camus, P.;
Cazes, A.;
Chapellier, M.;
Charlieux, F.;
De Jésus, M.;
Dumoulin, L.;
Eitel, K.;
Filosofov, D.;
Foerster, N.;
Fourches, N.;
Garde, G.;
Gascon, J.;
Giuliani, A.;
Grollier, M.;
Gros, M.;
Hehn, L.;
Hervé, S.;
Heuermann, G.;
Humbert, V.;
Jin, Y.;
Juillard, A.;
Kéfélian, C.;
Kleifges, M.;
Kozlov, V.;
Kraus, H.;
Kudryavtsev, V. A.;
Le-Sueur, H.;
Lin, J.;
Maisonobe, R.;
Mancuso, M.;
Marnieros, S.;
Menshikov, A.;
Navick, X. -F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Poda, D.;
Queguiner, E.;
Robinson, M.;
Rodenas, H.;
Rozov, S.;
Sanglard, V.;
Schmidt, B.;
Scorza, S.;
Siebenborn, B.;
Tcherniakhovski, D.;
Vagneron, L.;
Weber, M.;
Yakushev, E.;
Zhang, X.;
Zolotarova, A.
Submitted: 2017-06-04
We present the results of measurements demonstrating the efficiency of the
EDELWEISS-III array of cryogenic germanium detectors for direct dark matter
searches. The experimental setup and the FID (Fully Inter-Digitized) detector
array is described, as well as the efficiency of the double measurement of heat
and ionization signals in background rejection. For the whole set of 24 FID
detectors used for coincidence studies, the baseline resolutions for the
fiducial ionization energy are mainly below 0.7 keV$_{ee}$ (FHWM) whereas the
baseline resolutions for heat energies are mainly below 1.5 keV$_{ee}$ (FWHM).
The response to nuclear recoils as well as the very good discrimination
capability of the FID design has been measured with an AmBe source. The surface
$\beta$- and $\alpha$-decay rejection power of $R_{\rm surf} < 4 \times
10^{-5}$ per $\alpha$ at 90% C.L. has been determined with a $^{210}$Pb source,
the rejection of bulk $\gamma$-ray events has been demonstrated using
$\gamma$-calibrations with $^{133}$Ba sources leading to a value of
$R_{\gamma{\rm -mis-fid}} < 2.5 \times 10^{-6}$ at 90% C.L.. The current levels
of natural radioactivity measured in the detector array are shown as the rate
of single $\gamma$ background. The fiducial volume fraction of the FID
detectors has been measured to a weighted average value of $(74.6 \pm 0.4)\%$
using the cosmogenic activation of the $^{65}$Zn and $^{68,71}$Ge isotopes. The
stability and uniformity of the detector response is also discussed. The
achieved resolutions, thresholds and background levels of the upgraded
EDELWEISS-III detectors in their setup are thus well suited to the direct
search of WIMP dark matter over a large mass range.
[11]
oai:arXiv.org:1705.04736 [pdf] - 1648564
Input Comparison of Radiogenic Neutron Estimates for Ultra-low
Background Experiments
Submitted: 2017-05-12
Ultra-low-background experiments address some of the most important open
questions in particle physics, cosmology and astrophysics: the nature of dark
matter, whether the neutrino is its own antiparticle, and does the proton
decay. These rare event searches require well-understood and minimized
backgrounds. Simulations are used to understand backgrounds caused by naturally
occurring radioactivity in the rock and in every piece of shielding and
detector material used in these experiments. Most important are processes like
spontaneous fission and ({\alpha},n) reactions in material close to the
detectors that can produce neutrons. A comparison study between two dedicated
software packages is detailed. The cross section libraries, neutron yields, and
spectra from the Mei-Zhang-Hime and the SOURCES-4A codes are presented. The
resultant yields and spectra are used as inputs to direct dark matter detector
toy models in GEANT4, to study the impact of their differences on background
estimates and fits. Although differences in neutron yield calculations up to
50% were seen, there was no systematic difference between the Mei-Hime-Zhang
and SOURCES-4A results. Neutron propagation simulations smooth differences in
spectral shape and yield, and both tools were found to meet the broad
requirements of the low-background community.
[12]
oai:arXiv.org:1607.03367 [pdf] - 1497465
Improved EDELWEISS-III sensitivity for low-mass WIMPs using a profile
likelihood approach
EDELWEISS Collaboration;
Hehn, L.;
Armengaud, E.;
Arnaud, Q.;
Augier, C.;
Benoît, A.;
Bergé, L.;
Billard, J.;
Blümer, J.;
de Boissière, T.;
Broniatowski, A.;
Camus, P.;
Cazes, A.;
Chapellier, M.;
Charlieux, F.;
De Jésus, M.;
Dumoulin, L.;
Eitel, K.;
Foerster, N.;
Gascon, J.;
Giuliani, A.;
Gros, M.;
Heuermann, G.;
Jin, Y.;
Juillard, A.;
Kéfélian, C.;
Kleifges, M.;
Kozlov, V.;
Kraus, H.;
Kudryavtsev, V. A.;
Le-Sueur, H.;
Marnieros, S.;
Navick, X. -F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Piro, M. -C.;
Poda, D.;
Queguiner, E.;
Rozov, S.;
Sanglard, V.;
Schmidt, B.;
Scorza, S.;
Siebenborn, B.;
Tcherniakhovski, D.;
Vagneron, L.;
Weber, M.;
Yakushev, E.
Submitted: 2016-07-12, last modified: 2016-09-20
We report on a dark matter search for a Weakly Interacting Massive Particle
(WIMP) in the mass range $m_\chi \in [4, 30]\,\mathrm{GeV}/c^2$ with the
EDELWEISS-III experiment. A 2D profile likelihood analysis is performed on data
from eight selected detectors with the lowest energy thresholds leading to a
combined fiducial exposure of 496 kg-days. External backgrounds from $\gamma$-
and $\beta$-radiation, recoils from $^{206}$Pb and neutrons as well as detector
intrinsic backgrounds were modelled from data outside the region of interest
and constrained in the analysis. The basic data selection and most of the
background models are the same as those used in a previously published analysis
based on Boosted Decision Trees (BDT). For the likelihood approach applied in
the analysis presented here, a larger signal efficiency and a subtraction of
the expected background lead to a higher sensitivity, especially for the lowest
WIMP masses probed. No statistically significant signal was found and upper
limits on the spin-independent WIMP-nucleon scattering cross section can be set
with a hypothesis test based on the profile likelihood test statistics. The 90%
C.L. exclusion limit set for WIMPs with $m_\chi = 4\,\mathrm{GeV/}c^2$ is $1.6
\times 10^{-39}\,\mathrm{cm^2}$, which is an improvement of a factor of seven
with respect to the BDT-based analysis. For WIMP masses above
$15\,\mathrm{GeV/}c^2$ the exclusion limits found with both analyses are in
good agreement.
[13]
oai:arXiv.org:1503.03379 [pdf] - 1458536
Dark matter effective field theory scattering in direct detection
experiments
Schneck, K.;
Cabrera, B.;
Cerdeno, D. G.;
Mandic, V.;
Rogers, H. E.;
Agnese, R.;
Anderson, A. J.;
Asai, M.;
Balakishiyeva, D.;
Barker, D.;
Thakur, R. Basu;
Bauer, D. A.;
Billard, J.;
Borgland, A.;
Brandt, D.;
Brink, P. L.;
Bunker, R.;
Caldwell, D. O.;
Calkins, R.;
Chagani, H.;
Chen, Y.;
Cooley, J.;
Cornell, B.;
Crewdson, C. H.;
Cushman, P.;
Daal, M.;
Di Stefano, P. C. F.;
Doughty, T.;
Esteban, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Harris, H. R.;
Hofer, T.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Jardin, D. M.;
Jastram, A.;
Kamaev, O.;
Kara, B.;
Kelsey, M. H.;
Kennedy, A.;
Leder, A.;
Loer, B.;
Asamar, E. Lopez;
Lukens, P.;
Mahapatra, R.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moffatt, R. A.;
Mendoza, J. D. Morales;
Oser, S. M.;
Page, K.;
Page, W. A.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Prasad, K.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Ricci, Y.;
Roberts, A.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schnee, R. W.;
Scorza, S.;
Serfass, B.;
Shank, B.;
Speller, D.;
Toback, D.;
Upadhyayula, S.;
Villano, A. N.;
Welliver, B.;
Wilson, J. S.;
Wright, D. H.;
Yang, X.;
Yellin, S.;
Yen, J. J.;
Young, B. A.;
Zhang, J.
Submitted: 2015-03-11, last modified: 2016-08-16
We examine the consequences of the effective field theory (EFT) of dark
matter-nucleon scattering for current and proposed direct detection
experiments. Exclusion limits on EFT coupling constants computed using the
optimum interval method are presented for SuperCDMS Soudan, CDMS II, and LUX,
and the necessity of combining results from multiple experiments in order to
determine dark matter parameters is discussed. We demonstrate that spectral
differences between the standard dark matter model and a general EFT
interaction can produce a bias when calculating exclusion limits and when
developing signal models for likelihood and machine learning techniques. We
also discuss the implications of the EFT for the next-generation (G2) direct
detection experiments and point out regions of complementarity in the EFT
parameter space.
[14]
oai:arXiv.org:1607.04560 [pdf] - 1438577
Measurement of the cosmogenic activation of germanium detectors in
EDELWEISS-III
The EDELWEISS Collaboration;
Armengaud, E.;
Arnaud, Q.;
Augier, C.;
Benoît, A.;
Bergé, L.;
Billard, J.;
Blümer, J.;
de Boissière, T.;
Broniatowski, A.;
Camus, P.;
Cazes, A.;
Chapellier, M.;
Charlieux, F.;
De Jésus, M.;
Dumoulin, L.;
Eitel, K.;
Foerster, N.;
Gascon, J.;
Giuliani, A.;
Gros, M.;
Hehn, L.;
Heuermann, G.;
Jin, Y.;
Juillard, A.;
Kéfélian, C.;
Kleifges, M.;
Kozlov, V.;
Kraus, H.;
Kudryavtsev, V. A.;
Le-Sueur, H.;
Marnieros, S.;
Navick, X. -F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Piro, M. -C.;
Poda, D.;
Queguiner, E.;
Rozov, S.;
Sanglard, V.;
Schmidt, B.;
Scorza, S.;
Siebenborn, B.;
Tcherniakhovski, D.;
Vagneron, L.;
Weber, M.;
Yakushev, E.
Submitted: 2016-07-15
We present a measurement of the cosmogenic activation in the germanium
cryogenic detectors of the EDELWEISS III direct dark matter search experiment.
The decay rates measured in detectors with different exposures to cosmic rays
above ground are converted into production rates of different isotopes. The
measured production rates in units of nuclei/kg/day are 82 $\pm$ 21 for $^3$H,
2.8 $\pm$ 0.6 for $^{49}$V, 4.6 $\pm$ 0.7 for $^{55}$Fe, and 106 $\pm$ 13 for
$^{65}$Zn. These results are the most accurate for these isotopes. A lower
limit on the production rate of $^{68}$Ge of 74 nuclei/kg/day is also
presented. They are compared to model predictions present in literature and to
estimates calculated with the ACTIVIA code.
[15]
oai:arXiv.org:1606.08097 [pdf] - 1507589
Signals induced by charge-trapping in EDELWEISS FID detectors:
analytical modeling and applications
The EDELWEISS Collaboration;
Arnaud, Q.;
Armengaud, E.;
Augier, C.;
Benoît, A.;
Bergé, L.;
Billard, J.;
Blümer, J.;
de Boissière, T.;
Broniatowski, A.;
Camus, P.;
Cazes, A.;
Chapellier, M.;
Charlieux, F.;
Dumoulin, L.;
Eitel, K.;
Foerster, N.;
Fourches, N.;
Gascon, J.;
Giuliani, A.;
Gros, M.;
Hehn, L.;
Heuermann, G.;
De Jésus, M.;
Jin, Y.;
Juillard, A.;
Kleifges, M.;
Kozlov, V.;
Kraus, H.;
Kéfélian, C.;
Kudryavtsev, V. A.;
Le-Sueur, H.;
Marnieros, S.;
Navick, X. -F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Piro, M. -C.;
Poda, D.;
Queguiner, E.;
Rozov, S.;
Sanglard, V.;
Schmidt, B.;
Scorza, S.;
Siebenborn, B.;
Tcherniakhovski, D.;
Vagneron, L.;
Weber, M.;
Yakushev, E.
Submitted: 2016-06-26, last modified: 2016-06-29
The EDELWEISS-III direct dark matter search experiment uses cryogenic HP-Ge
detectors Fully covered with Inter-Digitized electrodes (FID). They are
operated at low fields ($<1\;\mathrm{V/cm}$), and as a consequence
charge-carrier trapping significantly affects both the ionization and heat
energy measurements. This paper describes an analytical model of the signals
induced by trapped charges in FID detectors based on the Shockley-Ramo theorem.
It is used to demonstrate that veto electrodes, initially designed for the sole
purpose of surface event rejection, can be used to provide a sensitivity to the
depth of the energy deposits, characterize the trapping in the crystals,
perform heat and ionization energy corrections and improve the ionization
baseline resolutions. These procedures are applied successfully to actual data.
[16]
oai:arXiv.org:1603.05120 [pdf] - 1403150
Constraints on low-mass WIMPs from the EDELWEISS-III dark matter search
EDELWEISS Collaboration;
Armengaud, E.;
Arnaud, Q.;
Augier, C.;
Benoît, A.;
Benoît, A.;
Bergé, L.;
Bergmann, T.;
Billard, J.;
Blümer, J.;
de Boissière, T.;
Bres, G.;
Broniatowski, A.;
Brudanin, V.;
Camus, P.;
Cazes, A.;
Chapellier, M.;
Charlieux, F.;
Dumoulin, L.;
Eitel, K.;
Filosofov, D.;
Foerster, N.;
Fourches, N.;
Garde, G.;
Gascon, J.;
Gerbier, G.;
Giuliani, A.;
Grollier, M.;
Gros, M.;
Hehn, L.;
Hervé, S.;
Heuermann, G.;
Humbert, V.;
De Jésus, M.;
Jin, Y.;
Jokisch, S.;
Juillard, A.;
Kéfélian, C.;
Kleifges, M.;
Kozlov, V.;
Kraus, H.;
Kudryavtsev, V. A.;
Le-Sueur, H.;
Lin, J.;
Mancuso, M.;
Marnieros, S.;
Menshikov, A.;
Navick, X. -F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Piro, M. -C.;
Poda, D. V.;
Queguiner, E.;
Robinson, M.;
Rodenas, H.;
Rozov, S.;
Sanglard, V.;
Schmidt, B.;
Scorza, S.;
Siebenborn, B.;
Tcherniakhovski, D.;
Vagneron, L.;
Weber, M.;
Yakushev, E.;
Zhang, X.
Submitted: 2016-03-16, last modified: 2016-05-09
We present the results of a search for elastic scattering from galactic dark
matter in the form of Weakly Interacting Massive Particles (WIMPs) in the 4-30
GeV/$c^2$ mass range. We make use of a 582 kg-day fiducial exposure from an
array of 800 g Germanium bolometers equipped with a set of interleaved
electrodes with full surface coverage. We searched specifically for $\sim
2.5-20$ keV nuclear recoils inside the detector fiducial volume. As an
illustration the number of observed events in the search for 5 (resp. 20)
GeV/$c^2$ WIMPs are 9 (resp. 4), compared to an expected background of 6.1
(resp. 1.4). A 90% CL limit of $4.3\times 10^{-40}$ cm$^2$ (resp. $9.4\times
10^{-44}$ cm$^2$) is set on the spin-independent WIMP-nucleon scattering
cross-section for 5 (resp. 20) GeV/$c^2$ WIMPs. This result represents a
41-fold improvement with respect to the previous EDELWEISS-II low-mass WIMP
search for 7 GeV/$c^2$ WIMPs. The derived constraint is in tension with hints
of WIMP signals from some recent experiments, thus confirming results obtained
with different detection techniques.
[17]
oai:arXiv.org:1509.02448 [pdf] - 1371572
WIMP-Search Results from the Second CDMSlite Run
SuperCDMS Collaboration;
Agnese, R.;
Anderson, A. J.;
Aramaki, T.;
Asai, M.;
Baker, W.;
Balakishiyeva, D.;
Barker, D.;
Thakur, R. Basu;
Bauer, D. A.;
Billard, J.;
Borgland, A.;
Bowles, M. A.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Calkins, R.;
Cerdeno, D. G.;
Chagani, H.;
Chen, Y.;
Cooley, J.;
Cornell, B.;
Cushman, P.;
Daal, M.;
Di Stefano, P. C. F.;
Doughty, T.;
Esteban, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Ghaith, M.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Harris, H. R.;
Hofer, T.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Jardin, D.;
Jastram, A.;
Kamaev, O.;
Kara, B.;
Kelsey, M. H.;
Kennedy, A.;
Leder, A.;
Loer, B.;
Asamar, E. Lopez;
Lukens, P.;
Mahapatra, R.;
Mandic, V.;
Mast, N.;
Mirabolfathi, N.;
Moffatt, R. A.;
Mendoza, J. D. Morales;
Oser, S. M.;
Page, K.;
Page, W. A.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Prasad, K.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Ricci, Y.;
Roberts, A.;
Rogers, H. E.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schneck, K.;
Schnee, R. W.;
Scorza, S.;
Serfass, B.;
Shank, B.;
Speller, D.;
Toback, D.;
Underwood, R.;
Upadhyayula, S.;
Villano, A. N.;
Welliver, B.;
Wilson, J. S.;
Wright, D. H.;
Yellin, S.;
Yen, J. J.;
Young, B. A.;
Zhang, J.
Submitted: 2015-09-08, last modified: 2016-03-09
The CDMS low ionization threshold experiment (CDMSlite) uses cryogenic
germanium detectors operated at a relatively high bias voltage to amplify the
phonon signal in the search for weakly interacting massive particles (WIMPs).
Results are presented from the second CDMSlite run with an exposure of 70 kg
days, which reached an energy threshold for electron recoils as low as 56 eV. A
fiducialization cut reduces backgrounds below those previously reported by
CDMSlite. New parameter space for the WIMP-nucleon spin-independent cross
section is excluded for WIMP masses between 1.6 and 5.5 GeV/$c^2$.
[18]
oai:arXiv.org:1504.05871 [pdf] - 1293576
Improved WIMP-search reach of the CDMS II germanium data
Agnese, R.;
Anderson, A. J.;
Asai, M.;
Balakishiyeva, D.;
Barker, D.;
Thakur, R. Basu;
Bauer, D. A.;
Billard, J.;
Borgland, A.;
Bowles, M. A.;
Brandt, D.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Calkins, R.;
Cerdeño, D. G.;
Chagani, H.;
Chen, Y.;
Cooley, J.;
Cornell, B.;
Crewdson, C. H.;
Cushman, P.;
Daal, M.;
Di Stefano, P. C. F.;
Doughty, T.;
Esteban, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Harris, H. R.;
Hertel, S. A.;
Hofer, T.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Jardin, D.;
Jastram, A.;
Kamaev, O.;
Kara, B.;
Kelsey, M. H.;
Kennedy, A.;
Kiveni, M.;
Koch, K.;
Leder, A.;
Loer, B.;
Asamar, E. Lopez;
Lukens, P.;
Mahapatra, R.;
Mandic, V.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moffatt, R. A.;
Oser, S. M.;
Page, K.;
Page, W. A.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Prasad, K.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Ricci, Y.;
Rogers, H. E.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schneck, K.;
Schnee, R. W.;
Scorza, S.;
Serfass, B.;
Shank, B.;
Speller, D.;
Toback, D.;
Upadhyayula, S.;
Villano, A. N.;
Welliver, B.;
Wilson, J. S.;
Wright, D. H.;
Yang, X.;
Yellin, S.;
Yen, J. J.;
Young, B. A.;
Zhang, J.
Submitted: 2015-04-22, last modified: 2015-10-13
CDMS II data from the 5-tower runs at the Soudan Underground Laboratory were
reprocessed with an improved charge-pulse fitting algorithm. Two new analysis
techniques to reject surface-event backgrounds were applied to the 612 kg days
germanium-detector WIMP-search exposure. An extended analysis was also
completed by decreasing the 10 keV analysis threshold to $\sim$5 keV, to
increase sensitivity near a WIMP mass of 8 GeV/$c^2$. After unblinding, there
were zero candidate events above a deposited energy of 10 keV and 6 events in
the lower-threshold analysis. This yielded minimum WIMP-nucleon
spin-independent scattering cross-section limits of $1.8 \times 10^{-44}$ and
$1.18 \times 10 ^{-41}$ cm$^2$ at 90\% confidence for 60 and 8.6 GeV/$c^2$
WIMPs, respectively. This improves the previous CDMS II result by a factor of
2.4 (2.7) for 60 (8.6) GeV/$c^2$ WIMPs.
[19]
oai:arXiv.org:1409.3270 [pdf] - 969775
First direct limits on Lightly Ionizing Particles with electric charge
less than $e/6$
Agnese, R.;
Anderson, A. J.;
Balakishiyeva, D.;
Thakur, R. Basu;
Bauer, D. A.;
Billard, J.;
Borgland, A.;
Bowles, M. A.;
Brandt, D.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Cerdeno, D. G.;
Chagani, H.;
Chen, Y.;
Cooley, J.;
Cornell, B.;
Crewdson, C. H.;
Cushman, P.;
Daal, M.;
Di Stefano, P. C. F.;
Doughty, T.;
Esteban, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Harris, H. R.;
Hertel, S. A.;
Hofer, T.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Jastram, A.;
Kamaev, O.;
Kara, B.;
Kelsey, M. H.;
Kennedy, A.;
Kiveni, M.;
Koch, K.;
Leder, A.;
Loer, B.;
Asamar, E. Lopez;
Mahapatra, R.;
Mandic, V.;
Martinez, C.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moffatt, R. A.;
Moore, D. C.;
Nelson, H.;
Nelson, R. H.;
Ogburn, R. W.;
Page, K.;
Page, W. A.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Prasad, K.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Ricci, Y.;
Rogers, H. E.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schneck, K.;
Schnee, R. W.;
Scorza, S.;
Serfass, B.;
Shank, B.;
Speller, D.;
Upadhyayula, S.;
Villano, A. N.;
Welliver, B.;
Wright, D. H.;
Yellin, S.;
Yen, J. J.;
Young, B. A.;
Zhang, J.
Submitted: 2014-09-10, last modified: 2015-02-03
While the Standard Model of particle physics does not include free particles
with fractional charge, experimental searches have not ruled out their
existence. We report results from the Cryogenic Dark Matter Search (CDMS II)
experiment that give the first direct-detection limits for
cosmogenically-produced relativistic particles with electric charge lower than
$e$/6. A search for tracks in the six stacked detectors of each of two of the
CDMS II towers found no candidates, thereby excluding new parameter space for
particles with electric charges between $e$/6 and $e$/200.
[20]
oai:arXiv.org:1410.1003 [pdf] - 975596
Maximum Likelihood Analysis of Low Energy CDMS II Germanium Data
SuperCDMS Collaboration;
Agnese, R.;
Anderson, A. J.;
Balakishiyeva, D.;
Thakur, R. Basu;
Bauer, D. A.;
Billard, J.;
Borgland, A.;
Bowles, M. A.;
Brandt, D.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Cerdeno, D. G.;
Chagani, H.;
Chen, Y.;
Cooley, J.;
Cornell, B.;
Crewdson, C. H.;
Cushman, P.;
Daal, M.;
Di Stefano, P. C. F.;
Doughty, T.;
Esteban, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Fritts, M.;
Godfrey, G. L.;
Golwala, S. R.;
Graham, M.;
Hall, J.;
Harris, H. R.;
Hertel, S. A.;
Hofer, T.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Jastram, A.;
Kamaev, O.;
Kara, B.;
Kelsey, M. H.;
Kennedy, A.;
Kiveni, M.;
Koch, K.;
Leder, A.;
Loer, B.;
Asamar, E. Lopez;
Mahapatra, R.;
Mandic, V.;
Martinez, C.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moffatt, R. A.;
Moore, D. C.;
Nelson, R. H.;
Oser, S. M.;
Page, K.;
Page, W. A.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Prasad, K.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Ricci, Y.;
Rogers, H. E.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schneck, K.;
Schnee, R. W.;
Scorza, S.;
Serfass, B.;
Shank, B.;
Speller, D.;
Upadhyayula, S.;
Villano, A. N.;
Welliver, B.;
Wright, D. H.;
Yellin, S.;
Yen, J. J.;
Young, B. A.;
Zhang, J.
Submitted: 2014-10-03
We report on the results of a search for a Weakly Interacting Massive
Particle (WIMP) signal in low-energy data of the Cryogenic Dark Matter Search
(CDMS~II) experiment using a maximum likelihood analysis. A background model is
constructed using GEANT4 to simulate the surface-event background from
$^{210}$Pb decay-chain events, while using independent calibration data to
model the gamma background. Fitting this background model to the data results
in no statistically significant WIMP component. In addition, we perform fits
using an analytic ad hoc background model proposed by Collar and Fields, who
claimed to find a large excess of signal-like events in our data. We confirm
the strong preference for a signal hypothesis in their analysis under these
assumptions, but excesses are observed in both single- and multiple-scatter
events, which implies the signal is not caused by WIMPs, but rather reflects
the inadequacy of their background model.
[21]
oai:arXiv.org:1402.7137 [pdf] - 841566
Search for Low-Mass WIMPs with SuperCDMS
Agnese, R.;
Anderson, A. J.;
Asai, M.;
Balakishiyeva, D.;
Thakur, R. Basu;
Bauer, D. A.;
Beaty, J.;
Billard, J.;
Borgland, A.;
Bowles, M. A.;
Brandt, D.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Cerdeno, D. G.;
Chagani, H.;
Chen, Y.;
Cherry, M.;
Cooley, J.;
Cornell, B.;
Crewdson, C. H.;
Cushman, P.;
Daal, M.;
DeVaney, D.;
Di Stefano, P. C. F.;
Silva, E. Do Couto E;
Doughty, T.;
Esteban, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Hansen, S.;
Harris, H. R.;
Hertel, S. A.;
Hines, B. A.;
Hofer, T.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Jastram, A.;
Kamaev, O.;
Kara, B.;
Kelsey, M. H.;
Kenany, S.;
Kennedy, A.;
Kiveni, M.;
Koch, K.;
Leder, A.;
Loer, B.;
Asamar, E. Lopez;
Mahapatra, R.;
Mandic, V.;
Martinez, C.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moffatt, R. A.;
Nelson, R. H.;
Novak, L.;
Page, K.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Platt, M.;
Prasad, K.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Resch, R. W.;
Ricci, Y.;
Ruschman, M.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schmitt, R. L.;
Schneck, K.;
Schnee, R. W.;
Scorza, S.;
Seitz, D. N.;
Serfass, B.;
Shank, B.;
Speller, D.;
Tomada, A.;
Upadhyayula, S.;
Villano, A. N.;
Welliver, B.;
Wright, D. H.;
Yellin, S.;
Yen, J. J.;
Young, B. A.;
Zhang, J.
Submitted: 2014-02-28, last modified: 2014-03-12
We report a first search for weakly interacting massive particles (WIMPs)
using the background rejection capabilities of SuperCDMS. An exposure of 577
kg-days was analyzed for WIMPs with mass < 30 GeV/c2, with the signal region
blinded. Eleven events were observed after unblinding. We set an upper limit on
the spin-independent WIMP-nucleon cross section of 1.2e-42 cm2 at 8 GeV/c2.
This result is in tension with WIMP interpretations of recent experiments and
probes new parameter space for WIMP-nucleon scattering for WIMP masses < 6
GeV/c2.
[22]
oai:arXiv.org:1309.3259 [pdf] - 779590
CDMSlite: A Search for Low-Mass WIMPs using Voltage-Assisted
Calorimetric Ionization Detection in the SuperCDMS Experiment
Agnese, R.;
Anderson, A. J.;
Asai, M.;
Balakishiyeva, D.;
Thakur, R. Basu;
Bauer, D. A.;
Billard, J.;
Borgland, A.;
Bowles, M. A.;
Brandt, D.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Cerdeno, D. G.;
Chagani, H.;
Cooley, J.;
Cornell, B.;
Crewdson, C. H.;
Cushman, P.;
Daal, M.;
Di Stefano, P. C. F.;
Doughty, T.;
Esteban, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Harris, H. R.;
Hertel, S. A.;
Hofer, T.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Jastram, A.;
Kamaev, O.;
Kara, B.;
Kelsey, M. H.;
Kennedy, A.;
Kiveni, M.;
Koch, K.;
Loer, B.;
Asamar, E. Lopez;
Mahapatra, R.;
Mandic, V.;
Martinez, C.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moffatt, R. A.;
Moore, D. C.;
Nadeau, P.;
Nelson, R. H.;
Page, K.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Prasad, K.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Ricci, Y.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schneck, K.;
Schnee, R. W.;
Scorza, S.;
Serfass, B.;
Shank, B.;
Speller, D.;
Villano, A. N.;
Welliver, B.;
Wright, D. H.;
Yellin, S.;
Yen, J. J.;
Young, B. A.;
Zhang, J.
Submitted: 2013-09-12, last modified: 2013-12-20
SuperCDMS is an experiment designed to directly detect Weakly Interacting
Massive Particles (WIMPs), a favored candidate for dark matter ubiquitous in
the Universe. In this paper, we present WIMP-search results using a
calorimetric technique we call CDMSlite, which relies on voltage- assisted
Luke-Neganov amplification of the ionization energy deposited by particle
interactions. The data were collected with a single 0.6 kg germanium detector
running for 10 live days at the Soudan Underground Laboratory. A low energy
threshold of 170 eVee (electron equivalent) was obtained, which allows us to
constrain new WIMP-nucleon spin-independent parameter space for WIMP masses
below 6 GeV/c2.
[23]
oai:arXiv.org:1304.4279 [pdf] - 732067
Silicon Detector Dark Matter Results from the Final Exposure of CDMS II
CDMS Collaboration;
Agnese, R.;
Ahmed, Z.;
Anderson, A. J.;
Arrenberg, S.;
Balakishiyeva, D.;
Thakur, R. Basu;
Bauer, D. A.;
Billard, J.;
Borgland, A.;
Brandt, D.;
Brink, P. L.;
Bruch, T.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Cerdeno, D. G.;
Chagani, H.;
Cooley, J.;
Cornell, B.;
Crewdson, C. H.;
Cushman, P.;
Daal, M.;
Dejongh, F.;
Silva, E. Do Couto E;
Doughty, T.;
Esteban, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Filippini, J.;
Fox, J.;
Fritts, M.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Harris, R. H.;
Hertel, S. A.;
Hofer, T.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Jastram, A.;
Kamaev, O.;
Kara, B.;
Kelsey, M. H.;
Kennedy, A.;
Kim, P.;
Kiveni, M.;
Koch, K.;
Kos, M.;
Leman, S. W.;
Loer, B.;
Asamar, E. Lopez;
Mahapatra, R.;
Mandic, V.;
Martinez, C.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moffatt, R. A.;
Moore, D. C.;
Nadeau, P.;
Nelson, R. H.;
Page, K.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Prasad, K.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Ricci, Y.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schneck, K.;
Schnee, R. W.;
Scorza, S.;
Serfass, B.;
Shank, B.;
Speller, D.;
Sundqvist, K. M.;
Villano, A. N.;
Welliver, B.;
Wright, D. H.;
Yellin, S.;
Yen, J. J.;
Yoo, J.;
Young, B. A.;
Zhang, J.
Submitted: 2013-04-15, last modified: 2013-10-11
We report results of a search for Weakly Interacting Massive Particles
(WIMPS) with the silicon detectors of the CDMS II experiment. This blind
analysis of 140.2 kg-days of data taken between July 2007 and September 2008
revealed three WIMP-candidate events with a surface-event background estimate
of 0.41^{+0.20}_{-0.08}(stat.)^{+0.28}_{-0.24}(syst.). Other known backgrounds
from neutrons and 206Pb are limited to < 0.13 and <0.08 events at the 90%
confidence level, respectively. The exposure of this analysis is equivalent to
23.4 kg-days for a recoil energy range of 7-100 keV for a WIMP of mass 10
GeV/c2. The probability that the known backgrounds would produce three or more
events in the signal region is 5.4%. A profile likelihood ratio test of the
three events that includes the measured recoil energies gives a 0.19%
probability for the known-background-only hypothesis when tested against the
alternative WIMP+background hypothesis. The highest likelihood occurs for a
WIMP mass of 8.6 GeV/c2 and WIMP-nucleon cross section of 1.9e-41 cm2.
[24]
oai:arXiv.org:1305.2405 [pdf] - 1530127
Demonstration of Surface Electron Rejection with Interleaved Germanium
Detectors for Dark Matter Searches
Agnese, R.;
Anderson, A. J.;
Balakishiyeva, D.;
Thakur, R. Basu;
Bauer, D. A.;
Borgland, A.;
Brandt, D.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Cerdeno, D. G.;
Chagani, H.;
Cherry, M.;
Cooley, J.;
Cornell, B.;
Crewdson, C. H.;
Cushman, P.;
Daal, M.;
Di Stefano, P. C. F.;
Silva, E. Do Couto E;
Doughty, T.;
Esteban, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Fox, J.;
Fritts, M.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Harris, H. R.;
Hasi, J.;
Hertel, S. A.;
Hines, B. A.;
Hofer, T.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Jastram, A.;
Kamaev, O.;
Kara, B.;
Kelsey, M. H.;
Kenany, S. A.;
Kennedy, A.;
Kenney, C. J.;
Kiveni, M.;
Koch, K.;
Loer, B.;
Asamar, E. Lopez;
Mahapatra, R.;
Mandic, V.;
Martinez, C.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moffatt, R. A.;
Moore, D. C.;
Nadeau, P.;
Nelson, R. H.;
Novak, L.;
Page, K.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Prasad, K.;
Pyle, M.;
Qiu, H.;
Radpour, R.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Resch, R. W.;
Ricci, Y.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schmitt, R.;
Schneck, K.;
Schnee, R. W.;
Scorza, S.;
Seitz, D.;
Serfass, B.;
Shank, B.;
Speller, D.;
Tomada, A.;
Villano, A. N.;
Welliver, B.;
Wright, D. H.;
Yellin, S.;
Yen, J. J.;
Young, B. A.;
Zhang, J.
Submitted: 2013-05-10, last modified: 2013-10-04
The SuperCDMS experiment in the Soudan Underground Laboratory searches for
dark matter with a 9-kg array of cryogenic germanium detectors. Symmetric
sensors on opposite sides measure both charge and phonons from each particle
interaction, providing excellent discrimination between electron and nuclear
recoils, and between surface and interior events. Surface event rejection
capabilities were tested with two $^{210}$Pb sources producing $\sim$130 beta
decays/hr. In $\sim$800 live hours, no events leaked into the 8--115 keV signal
region, giving upper limit leakage fraction $1.7 \times 10^{-5}$ at 90% C.L.,
corresponding to $< 0.6$ surface event background in the future 200-kg
SuperCDMS SNOLAB experiment.
[25]
oai:arXiv.org:1304.3706 [pdf] - 719385
Silicon detector results from the first five-tower run of CDMS II
CDMS Collaboration;
Agnese, R.;
Ahmed, Z.;
Anderson, A. J.;
Arrenberg, S.;
Balakishiyeva, D.;
Thakur, R. Basu;
Bauer, D. A.;
Borgland, A.;
Brandt, D.;
Brink, P. L.;
Bruch, T.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Cerdeno, D. G.;
Chagani, H.;
Cooley, J.;
Cornell, B.;
Crewdson, C. H.;
Cushman, P.;
Daal, M.;
Dejongh, F.;
Di Stefano, P. C. F.;
Silva, E. do Couto e;
Doughty, T.;
Esteban, L.;
Fallows, S.;
Figueroa-Feliciano, E.;
Filippini, J.;
Fox, J.;
Fritts, M.;
Godfrey, G. L.;
Golwala, S. R.;
Hall, J.;
Harris, R. H.;
Hertel, S. A.;
Hofer, T.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Jastram, A.;
Kamaev, O.;
Kara, B.;
Kelsey, M. H.;
Kennedy, A.;
Kim, P.;
Kiveni, M.;
Koch, K.;
Kos, M.;
Leman, S. W.;
Lopez-Asamar, E.;
Mahapatra, R.;
Mandic, V.;
Martinez, C.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moffatt, R. A.;
Moore, D. C.;
Nadeau, P.;
Nelson, R. H.;
Page, K.;
Partridge, R.;
Pepin, M.;
Phipps, A.;
Prasad, K.;
Pyle, M.;
Qiu, H.;
Rau, W.;
Redl, P.;
Reisetter, A.;
Ricci, Y.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Schneck, K.;
Schnee, R. W.;
Scorza, S.;
Serfass, B.;
Shank, B.;
Speller, D.;
Sundqvist, K. M.;
Villano, A. N.;
Welliver, B.;
Wright, D. H.;
Yellin, S.;
Yen, J. J.;
Yoo, J.;
Young, B. A.;
Zhan, J.
Submitted: 2013-04-12, last modified: 2013-09-14
We report results of a search for Weakly Interacting Massive Particles
(WIMPs) with the Si detectors of the CDMS II experiment. This report describes
a blind analysis of the first data taken with CDMS II's full complement of
detectors in 2006-2007; results from this exposure using the Ge detectors have
already been presented. We observed no candidate WIMP-scattering events in an
exposure of 55.9 kg-days before analysis cuts, with an expected background of
~1.1 events. The exposure of this analysis is equivalent to 10.3 kg-days over a
recoil energy range of 7-100 keV for an ideal Si detector and a WIMP mass of 10
GeV/c2. These data set an upper limit of 1.7x10-41 cm2 on the WIMP-nucleon
spin-independent cross section of a 10 GeV/c2 WIMP. These data exclude
parameter space for spin-independent WIMP-nucleon elastic scattering that is
relevant to recent searches for low-mass WIMPs.
[26]
oai:arXiv.org:1103.4070 [pdf] - 966535
Final results of the EDELWEISS-II WIMP search using a 4-kg array of
cryogenic germanium detectors with interleaved electrodes
EDELWEISS Collaboration;
Armengaud, E.;
Augier, C.;
Benoît, A.;
Bergé, L.;
Blümer, J.;
Broniatowski, A.;
Brudanin, V.;
Censier, B.;
Chardin, G.;
Chapellier, M.;
Charlieux, F.;
Coulter, P.;
Cox, G. A.;
Defay, X.;
De Jesus, M.;
Dolgorouki, Y.;
Domange, J.;
Dumoulin, L.;
Eitel, K.;
Filosofov, D.;
Fourches, N.;
Gascon, J.;
Gerbier, G.;
Gironnet, J.;
Gros, M.;
Henry, S.;
Hervé, S.;
Juillard, A.;
Kluck, H.;
Kozlov, V.;
Kraus, H.;
Kudryavtsev, V. A.;
Loaiza, P.;
Marnieros, S.;
Navick, X-F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Pattavina, L.;
Paul, B.;
Robinson, M.;
Rozov, S.;
Sanglard, V.;
Schmidt, B.;
Scorza, S.;
Semikh, S.;
Torrento-Coello, A-S.;
Vagneron, L.;
Verdier, M-A.;
Walker, R. J.;
Yakushev, E.
Submitted: 2011-03-21, last modified: 2011-08-31
The EDELWEISS-II collaboration has completed a direct search for WIMP dark
matter with an array of ten 400-g cryogenic germanium detectors in operation at
the Laboratoire Souterrain de Modane. The combined use of thermal phonon
sensors and charge collection electrodes with an interleaved geometry enables
the efficient rejection of gamma-induced radioactivity as well as near-surface
interactions. A total effective exposure of 384 kg.d has been achieved, mostly
coming from fourteen months of continuous operation. Five nuclear recoil
candidates are observed above 20 keV, while the estimated background is 3.0
events. The result is interpreted in terms of limits on the cross-section of
spin-independent interactions of WIMPs and nucleons. A cross-section of
4.4x10^-8 pb is excluded at 90%CL for a WIMP mass of 85 GeV. New constraints
are also set on models where the WIMP-nucleon scattering is inelastic.
[27]
oai:arXiv.org:1105.3377 [pdf] - 966800
Combined Limits on WIMPs from the CDMS and EDELWEISS Experiments
CDMS;
Collaborations, EDELWEISS;
:;
Ahmed, Z.;
Akerib, D. S.;
Armengaud, E.;
Arrenberg, S.;
Augier, C.;
Bailey, C. N.;
Balakishiyeva, D.;
Baudis, L.;
Bauer, D. A.;
Benoît, A.;
Bergé, L.;
Blümer, J.;
Brink, P. L.;
Broniatowski, A.;
Bruch, T.;
Brudanin, V.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Censier, B.;
Chapellier, M.;
Chardin, G.;
Charlieux, F.;
Cooley, J.;
Coulter, P.;
Cox, G. A.;
Cushman, P.;
Daal, M.;
Defay, X.;
De Jesus, M.;
DeJongh, F.;
Di Stefano, P. C. F.;
Dolgorouki, Y.;
Domange, J.;
Dumoulin, L.;
Dragowsky, M. R.;
Eitel, K.;
Fallows, S.;
Figueroa-Feliciano, E.;
Filippini, J.;
Filosofov, D.;
Fourches, N.;
Fox, J.;
Fritts, M.;
Gascon, J.;
Gerbier, G.;
Gironnet, J.;
Golwala, S. R.;
Gros, M.;
Hall, J.;
Hennings-Yeomans, R.;
Henry, S.;
Hertel, S. A.;
Hervé, S.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Juillard, A.;
Kamaev, O.;
Kiveni, M.;
Kluck, H.;
Kos, M.;
Kozlov, V.;
Kraus, H.;
Kudryavtsev, V. A.;
Leman, S. W.;
Liu, S.;
Loaiza, P.;
Mahapatra, R.;
Mandic, V.;
Marnieros, S.;
Martinez, C.;
McCarthy, K. A.;
Mirabolfathi, N.;
Moore, D.;
Nadeau, P.;
Navick, X-F.;
Nelson, H.;
Nones, C.;
Ogburn, R. W.;
Olivieri, E.;
Pari, P.;
Pattavina, L.;
Paul, B.;
Phipps, A.;
Pyle, M.;
Qiu, X.;
Rau, W.;
Reisetter, A.;
Ricci, Y.;
Robinson, M.;
Rozov, S.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Sanglard, V.;
Schmidt, B.;
Schnee, R. W.;
Scorza, S.;
Seitz, D. N.;
Semikh, S.;
Serfass, B.;
Sundqvist, K. M.;
Tarka, M.;
Torrento-Coello, A. S.;
Vagneron, L.;
Verdier, M. -A.;
Walker, R. J.;
Wikus, P.;
Yakushev, E.;
Yellin, S.;
Yoo, J.;
Young, B. A.;
Zhang, J.
Submitted: 2011-05-17, last modified: 2011-07-08
The CDMS and EDELWEISS collaborations have combined the results of their
direct searches for dark matter using cryogenic germanium detectors. The total
data set represents 614 kg.d equivalent exposure. A straightforward method of
combination was chosen for its simplicity before data were exchanged between
experiments. The results are interpreted in terms of limits on spin-independent
WIMP-nucleon cross-section. For a WIMP mass of 90 GeV/c^2, where this analysis
is most sensitive, a cross-section of 3.3 x 10^{-44} cm^2 is excluded at 90%
CL. At higher WIMP masses, the combination improves the individual limits, by a
factor 1.6 above 700 GeV/c^2. Alternative methods of combining the data provide
stronger constraints for some ranges of WIMP masses and weaker constraints for
others.
[28]
oai:arXiv.org:1006.3098 [pdf] - 190656
A detection system to measure muon-induced neutrons for direct Dark
Matter searches
Kozlov, V. Yu.;
Armengaud, E.;
Augier, C.;
Benoit, A.;
Berge, L.;
Besida, O.;
Blumer, J.;
Broniatowski, A.;
Brudanin, V.;
Chantelauze, A.;
Chapellier, M.;
Chardin, G.;
Charlieux, F.;
Collin, S.;
Defay, X.;
De Jesus, M.;
Di Stefano, P.;
Dolgorouki, Y.;
Domange, J.;
Dumoulin, L.;
Eitel, K.;
Gascon, J.;
Gerbier, G.;
Gros, M.;
Hannawald, M.;
Herve, S.;
Juillard, A.;
Kluck, H.;
Lemrani, R.;
Loaiza, P.;
Lubashevskiy, A.;
Marnieros, S.;
Navick, X. -F.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Rozov, S.;
Sanglard, V.;
Scorza, S.;
Semikh, S.;
Torrento-Coello, A. S.;
Vagneron, L.;
Verdier, M-A.;
Yakushev, E.
Submitted: 2010-06-15
Muon-induced neutrons constitute a prominent background component in a number
of low count rate experiments, namely direct searches for Dark Matter. In this
work we describe a neutron detector to measure this background in an
underground laboratory, the Laboratoire Souterrain de Modane. The system is
based on 1 m3 of Gd-loaded scintillator and it is linked with the muon veto of
the EDELWEISS-II experiment for coincident muon detection. The system was
installed in autumn 2008 and passed since then a number of commissioning tests
proving its full functionality. The data-taking is continuously ongoing and a
count rate of the order of 1 muon-induced neutron per day has been achieved.
[29]
oai:arXiv.org:1001.4383 [pdf] - 33100
Monitoring of the thermal neutron flux in the LSM underground laboratory
Rozov, S.;
Armengaud, E.;
Augier, C.;
Bergé, L.;
Benoit, A.;
Besida, O.;
Blümer, J.;
Broniatowski, A.;
Brudanin, V.;
Chantelauze, A.;
Chapellier, M.;
Chardin, G.;
Charlieux, F.;
Collin, S.;
Crauste, O.;
De Jesus, M.;
Defay, X.;
Di Stefano, P.;
Dolgorouki, Y.;
Domange, J.;
Dumoulin, L.;
Eitel, K.;
Filosofov, D.;
Gascon, J.;
Gerbier, G.;
Gros, M.;
Hannawald, M.;
Juillard, A.;
Kluck, H.;
Kozlov, V.;
Lemrani, R.;
Lubashevskiy, A.;
Marrach, C.;
Marnieros, S.;
Navick, X-F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Sanglard, V.;
Scorza, S.;
Semikh, S.;
Verdier, M-A.;
Vagneron, L.;
Yakushev, E.
Submitted: 2010-01-25
This paper describes precise measurements of the thermal neutron flux in the
LSM underground laboratory in proximity of the EDELWEISS-II dark matter search
experiment together with short measurements at various other locations.
Monitoring of the flux of thermal neutrons is accomplished using a mobile
detection system with low background proportional counter filled with $^3$He.
On average 75 neutrons per day are detected with a background level below 1
count per day (cpd). This provides a unique possibility of a day by day study
of variations of the neutron field in a deep underground site. The measured
average 4$\pi$ neutron flux per cm$^{2}$ in the proximity of EDELWEISS-II is
$\Phi_{MB}=3.57\pm0.05^{stat}\pm0.27^{syst}\times 10^{-6}$ neutrons/sec. We
report the first experimental observation that the point-to-point thermal
neutron flux at LSM varies by more than a factor two.
[30]
oai:arXiv.org:0912.0805 [pdf] - 157860
First results of the EDELWEISS-II WIMP search using Ge cryogenic
detectors with interleaved electrodes
Armengaud, E.;
Augier, C.;
Benoit, A.;
Berge, L.;
Besida, O.;
Blumer, J.;
Broniatowski, A.;
Chantelauze, A.;
Chapellier, M.;
Chardin, G.;
Charlieux, F.;
Collin, S.;
Defay, X.;
De Jesus, M.;
Di Stefano, P.;
Dolgorouki, Y.;
Domange, J.;
Dumoulin, L.;
Eitel, K.;
Gascon, J.;
Gerbier, G.;
Gros, M.;
Hannawald, M.;
Herve, S.;
Juillard, A.;
Kluck, H.;
Kozlov, V.;
Lemrani, R.;
Loaiza, P.;
Lubashevskiy, A.;
Marnieros, S.;
Navick, X-F.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Rozov, S.;
Sanglard, V.;
Scorza, S.;
Semikh, S.;
Torrento-Coello, A. S.;
Vagneron, L.;
Verdier, M-A.;
Yakushev, E.;
Collaboration, the EDELWEISS
Submitted: 2009-12-04
The EDELWEISS-II collaboration has performed a direct search for WIMP dark
matter with an array of ten 400 g heat-and-ionization cryogenic detectors
equipped with interleaved electrodes for the rejection of near-surface events.
Six months of continuous operation at the Laboratoire Souterrain de Modane have
been achieved. The observation of one nuclear recoil candidate above 20 keV in
an effective exposure of 144 kgd is interpreted in terms of limits on the
cross-section of spin-independent interactions of WIMPs and nucleons. A
cross-section of 1.0x10^-7 pb is excluded at 90%CL for a WIMP mass of 80
GeV/c2. This result demonstrates for the first time the very high background
rejection capabilities of these simple and robust detectors in an actual WIMP
search experiment.
[31]
oai:arXiv.org:0905.0753 [pdf] - 369040
A new high-background-rejection dark matter Ge cryogenic detector
Broniatowski, A.;
Defay, X.;
Armengaud, E.;
Berge, L.;
Benoit, A.;
Besida, O.;
Blumer, J.;
Chantelauze, A.;
Chapellier, M.;
Chardin, G.;
Charlieux, F.;
Collin, S.;
Crauste, O.;
De Jesus, M.;
Di Stefano, P.;
Dolgorouki, Y.;
Domange, J.;
Dumoulin, L.;
Eitel, K.;
Gascon, J.;
Gerbier, G.;
Gros, M.;
Hannawald, M.;
Herve, S.;
Juillard, A.;
Kluck, H.;
Kozlov, V.;
Lemrani, R.;
Lubashevskiy, A.;
Marrache, C.;
Marnieros, S.;
Navick, X. -F.;
Nones, C.;
Olivieri, E.;
Pari, P.;
Paul, B.;
Rozov, S.;
Sanglard, V.;
Scorza, S.;
Semikh, S.;
Verdier, M. -A.;
Vagneron, L.;
Yakushev, E.
Submitted: 2009-05-06
A new design of a cryogenic germanium detector for dark matter search is
presented, taking advantage of the coplanar grid technique of event
localisation for improved background discrimination. Experiments performed with
prototype devices in the EDELWEISS II setup at the Modane underground facility
demonstrate the remarkably high efficiency of these devices for the rejection
of low-energy $\beta$, approaching 10$^5$ . This opens the road to investigate
the range beyond 10$^{-8}$ pb in the WIMP-nucleon collision cross-sections, as
proposed in the EURECA project of a one-ton cryogenic detector mass.
[32]
oai:arXiv.org:0806.3147 [pdf] - 13707
The EDELWEISS-II experiment
Submitted: 2008-06-19
EDELWEISS is a direct dark matter search situated in the low radioactivity
environment of the Modane Underground Laboratory. The experiment uses Ge
detectors at very low temperature in order to identify eventual rare nuclear
recoils induced by elastic scattering of WIMPs from our Galactic halo. The
commissioning of the second phase of the experiment, involving more than 7 kg
of Ge, has been completed in 2007. Two new type of detectors with active
rejection of events due to surface contamination have demonstrated the
performances required to achieve the physics goal of the present phase.