Normalized to: Schwartz, N.
[1]
oai:arXiv.org:2006.08294 [pdf] - 2114371
Pyramid wavefront sensor optical gains compensation using a
convolutional model
Submitted: 2020-06-15
Extremely Large Telescopes have overwhelmingly opted for the Pyramid
wavefront sensor (PyWFS) over the more widely used Shack-Hartmann WaveFront
Sensor (SHWFS) to perform their Single Conjugate Adaptive Optics (SCAO) mode.
The PyWFS, a sensor based on Fourier filtering, has proven to be highly
successful in many astronomy applications. However, it exhibits non-linearity
behaviors that lead to a reduction of its sensitivity when working with
non-zero residual wavefronts. This so-called Optical Gains (OG) effect,
degrades the close loop performance of SCAO systems and prevents accurate
correction of Non-Common Path Aberrations (NCPA). In this paper, we aim at
computing the OG using a fast and agile strategy in order to control the PyWFS
measurements in adaptive optics closed loop systems. Using a novel theoretical
description of the PyFWS, which is based on a convolutional model, we are able
to analytically predict the behavior of the PyWFS in closed-loop operation.
This model enables us to explore the impact of residual wavefront error on
particular aspects such as sensitivity and associated OG. The proposed method
relies on the knowledge of the residual wavefront statistics and enables
automatic estimation of the current OG. End-to-End numerical simulations are
used to validate our predictions and test the relevance of our approach. We
demonstrate, using on non-invasive strategy, that our method provides an
accurate estimation of the OG. The model itself only requires AO telemetry data
to derive statistical information on atmospheric turbulence. Furthermore, we
show that by only using an estimation of the current Fried parameter r_0 and
the basic system-level characteristics, OGs can be estimated with an accuracy
of less than 10%. Finally, we highlight the importance of OG estimation in the
case of NCPA compensation. The proposed method is applied to the PyWFS.
[2]
oai:arXiv.org:2003.07228 [pdf] - 2064627
Design of the HARMONI Pyramid WFS module
Schwartz, Noah;
Sauvage, Jean-François;
Renault, Edgard;
Correia, Carlos;
Neichel, Benoit;
Fusco, Thierry;
Dohlen, Kjetil;
Hadi, Kacem El;
Petit, Cyril;
Choquet, Elodie;
Chambouleyron, Vincent;
Paufique, Jerome;
Clarke, Fraser;
Thatte, Niranjan;
Bryson, Ian
Submitted: 2020-03-13
Current designs for all three extremely large telescopes show the
overwhelming adoption of the pyramid wavefront sensor (P-WFS) as the WFS of
choice for adaptive optics (AO) systems sensing on natural guide stars (NGS) or
extended objects. The key advantages of the P-WFS over the Shack-Hartmann are
known and are mainly provided by the improved sensitivity (fainter NGS) and
reduced sensitivity to spatial aliasing. However, robustness and tolerances of
the P-WFS for the ELTs are not currently well understood. In this paper, we
present simulation results for the single-conjugate AO mode of HARMONI, a
visible and near-infrared integral field spectrograph for the European
Extremely Large Telescope. We first explore the wavefront sensing issues
related to the telescope itself; namely the island effect (i.e. differential
piston) and M1 segments phasing errors. We present mitigation strategies to the
island effect and their performance. We then focus on some performance
optimisation aspects of the AO design to explore the impact of the RTC latency
and the optical gain issues, which will in particular affect the high-contrast
mode of HARMONI. Finally, we investigate the influence of the quality of glass
pyramid prism itself, and of optical aberrations on the final AO performance.
By relaxing the tolerances on the fabrication of the prism, we are able to
reduce hardware costs and simplify integration. We show the importance of
calibration (i.e. updating the control matrix) to capture any displacement of
the telescope pupil and rotation of the support structure for M4. We also show
the importance of the number of pixels used for wavefront sensing to relax
tolerances of the pyramid prism. Finally, we present a detailed optical design
of the pyramid prism, central element of the P-WFS.
[3]
oai:arXiv.org:1809.08839 [pdf] - 1755233
Sensing and control of segmented mirrors with a pyramid wavefront sensor
in the presence of spiders
Schwartz, Noah;
Sauvage, Jean-François;
Correia, Carlos;
Petit, Cyril;
Quiros-Pacheco, Fernando;
Fusco, Thierry;
Dohlen, Kjetil;
Hadi, Kacem El;
Thatte, Niranjan;
Clarke, Fraser;
Paufique, Jérome;
Vernet, Joel
Submitted: 2018-09-24
The segmentation of the telescope pupil (by spiders & the segmented M4)
create areas of phase isolated by the width of the spiders on the wavefront
sensor (WFS), breaking the spatial continuity of the wavefront. The poor
sensitivity of the Pyramid WFS (PWFS) to differential piston leads to badly
seen and therefore uncontrollable differential pistons. In close loop
operation, differential pistons between segments will settle around integer
values of the average sensing wavelength. The differential pistons typically
range from one to ten times the sensing wavelength and vary rapidly over time,
leading to extremely poor performance. In addition, aberrations created by
atmospheric turbulence will contain large amounts of differential piston
between the segments. Removing piston contribution over each of the DM segments
leads to poor performance. In an attempt to reduce the impact of unwanted
differential pistons that are injected by the AO correction, we compare three
different approaches. We first limit ourselves to only use the information
measured by the PWFS, in particular by reducing the modulation. We show that
using this information sensibly is important but will not be sufficient. We
discuss possible ways of improvement by using prior information. A second
approach is based on phase closure of the DM commands and assumes the
continuity of the correction wavefront over the entire unsegmented pupil. The
last approach is based on the pair-wise slaving of edge actuators and shows the
best results. We compare the performance of these methods using realistic
end-to-end simulations. We find that pair-wise slaving leads to a small
increase of the total wavefront error, only adding between 20-45 nm RMS in
quadrature for seeing conditions between 0.45-0.85 arcsec. Finally, we discuss
the possibility of combining the different proposed solutions to increase
robustness.
[4]
oai:arXiv.org:1809.09097 [pdf] - 1756099
Laboratory Demonstration of an Active Optics System for High-Resolution
Deployable CubeSat
Schwartz, Noah;
Pearson, David;
Todd, Stephen;
Milanova, Maria;
Brzozowski, William;
Vick, Andy;
Lunney, David;
MacLeod, Donald;
Greenland, Steve;
Sauvage, Jean-François;
Gore, Benjamin
Submitted: 2018-09-24
In this paper we present HighRes: a laboratory demonstration of a 3U CubeSat
with a deployable primary mirror that has the potential of achieving
high-resolution imaging for Earth Observation. The system is based on a
Cassegrain telescope with a segmented primary mirror composed of 4 petals that
form an effective aperture of 300 mm. The design provides diffraction limited
performance over the entire field-of-view and allows for a panchromatic
ground-sampling distance of less than 1 m at an altitude of 350 km. The
alignment and co-phasing of the mirror segments is performed by focal plane
sharpening and is validated through rigorous numerical simulations. The
opto-mechanical design of the prototype and its laboratory demonstration are
described and measurements from the on-board metrology sensors are presented.
This data verifies that the performance of the mirror deployment and
manipulation systems is sufficient for co-phasing. In addition, it is shown
that the mirrors can be driven to any target position with an accuracy of 25 nm
using closed-loop feedback between the mirror motors and the on-board
metrology.
[5]
oai:arXiv.org:1805.11931 [pdf] - 1691645
The adaptive optics modes for HARMONI: from Classical to Laser Assisted
Tomographic AO
Neichel, B.;
Fusco, T.;
Sauvage, J. -F.;
Correia, C.;
Dohlen, K.;
El-Hadi, K.;
Blanco, L.;
Schwartz, N.;
Clarke, F.;
Thatte, N.;
Tecza, M.;
Paufique, J.;
Vernet, J.;
Louarn, M. Le;
Hammersley, P.;
Gach, J. -L.;
Pascal, S.;
Vola, P.;
Petit, C.;
Conan, J. -M.;
Carlotti, A.;
Verinaud, C.;
Schnetler, H.;
Bryson, I.;
Morris, T.;
Myers, R.;
Hugot, E.;
Gallie, A.
Submitted: 2018-05-30
HARMONI is a visible and NIR integral field spectrograph, providing the
E-ELT's core spectroscopic capability at first light. HARMONI will work at the
diffraction limit of the E-ELT, thanks to a Classical and a Laser Tomographic
AO system. In this paper, we present the system choices that have been made for
these SCAO and LTAO modules. In particular, we describe the strategy developed
for the different Wave-Front Sensors: pyramid for SCAO, the LGSWFS concept, the
NGSWFS path, and the truth sensor capabilities. We present first potential
implementations. And we asses the first system performance.