sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Schwartz, N.

Normalized to: Schwartz, N.

5 article(s) in total. 43 co-authors, from 1 to 5 common article(s). Median position in authors list is 1,0.

[1]  oai:arXiv.org:2006.08294  [pdf] - 2114371
Pyramid wavefront sensor optical gains compensation using a convolutional model
Comments:
Submitted: 2020-06-15
Extremely Large Telescopes have overwhelmingly opted for the Pyramid wavefront sensor (PyWFS) over the more widely used Shack-Hartmann WaveFront Sensor (SHWFS) to perform their Single Conjugate Adaptive Optics (SCAO) mode. The PyWFS, a sensor based on Fourier filtering, has proven to be highly successful in many astronomy applications. However, it exhibits non-linearity behaviors that lead to a reduction of its sensitivity when working with non-zero residual wavefronts. This so-called Optical Gains (OG) effect, degrades the close loop performance of SCAO systems and prevents accurate correction of Non-Common Path Aberrations (NCPA). In this paper, we aim at computing the OG using a fast and agile strategy in order to control the PyWFS measurements in adaptive optics closed loop systems. Using a novel theoretical description of the PyFWS, which is based on a convolutional model, we are able to analytically predict the behavior of the PyWFS in closed-loop operation. This model enables us to explore the impact of residual wavefront error on particular aspects such as sensitivity and associated OG. The proposed method relies on the knowledge of the residual wavefront statistics and enables automatic estimation of the current OG. End-to-End numerical simulations are used to validate our predictions and test the relevance of our approach. We demonstrate, using on non-invasive strategy, that our method provides an accurate estimation of the OG. The model itself only requires AO telemetry data to derive statistical information on atmospheric turbulence. Furthermore, we show that by only using an estimation of the current Fried parameter r_0 and the basic system-level characteristics, OGs can be estimated with an accuracy of less than 10%. Finally, we highlight the importance of OG estimation in the case of NCPA compensation. The proposed method is applied to the PyWFS.
[2]  oai:arXiv.org:2003.07228  [pdf] - 2064627
Design of the HARMONI Pyramid WFS module
Comments: 12 pages, 17 figures, AO4ELT6 Proceedings, Adaptive Optics for Extremely Large Telescopes 6, Conference Proceeding, Qu\'ebec City, Canada, Spain, June 9-14, 2019
Submitted: 2020-03-13
Current designs for all three extremely large telescopes show the overwhelming adoption of the pyramid wavefront sensor (P-WFS) as the WFS of choice for adaptive optics (AO) systems sensing on natural guide stars (NGS) or extended objects. The key advantages of the P-WFS over the Shack-Hartmann are known and are mainly provided by the improved sensitivity (fainter NGS) and reduced sensitivity to spatial aliasing. However, robustness and tolerances of the P-WFS for the ELTs are not currently well understood. In this paper, we present simulation results for the single-conjugate AO mode of HARMONI, a visible and near-infrared integral field spectrograph for the European Extremely Large Telescope. We first explore the wavefront sensing issues related to the telescope itself; namely the island effect (i.e. differential piston) and M1 segments phasing errors. We present mitigation strategies to the island effect and their performance. We then focus on some performance optimisation aspects of the AO design to explore the impact of the RTC latency and the optical gain issues, which will in particular affect the high-contrast mode of HARMONI. Finally, we investigate the influence of the quality of glass pyramid prism itself, and of optical aberrations on the final AO performance. By relaxing the tolerances on the fabrication of the prism, we are able to reduce hardware costs and simplify integration. We show the importance of calibration (i.e. updating the control matrix) to capture any displacement of the telescope pupil and rotation of the support structure for M4. We also show the importance of the number of pixels used for wavefront sensing to relax tolerances of the pyramid prism. Finally, we present a detailed optical design of the pyramid prism, central element of the P-WFS.
[3]  oai:arXiv.org:1809.08839  [pdf] - 1755233
Sensing and control of segmented mirrors with a pyramid wavefront sensor in the presence of spiders
Comments: 12 pages, 15 figures, AO4ELT5 Proceedings, Adaptive Optics for Extremely Large Telescopes 5, Conference Proceeding, Tenerife, Canary Islands, Spain, June 25-30, 2017
Submitted: 2018-09-24
The segmentation of the telescope pupil (by spiders & the segmented M4) create areas of phase isolated by the width of the spiders on the wavefront sensor (WFS), breaking the spatial continuity of the wavefront. The poor sensitivity of the Pyramid WFS (PWFS) to differential piston leads to badly seen and therefore uncontrollable differential pistons. In close loop operation, differential pistons between segments will settle around integer values of the average sensing wavelength. The differential pistons typically range from one to ten times the sensing wavelength and vary rapidly over time, leading to extremely poor performance. In addition, aberrations created by atmospheric turbulence will contain large amounts of differential piston between the segments. Removing piston contribution over each of the DM segments leads to poor performance. In an attempt to reduce the impact of unwanted differential pistons that are injected by the AO correction, we compare three different approaches. We first limit ourselves to only use the information measured by the PWFS, in particular by reducing the modulation. We show that using this information sensibly is important but will not be sufficient. We discuss possible ways of improvement by using prior information. A second approach is based on phase closure of the DM commands and assumes the continuity of the correction wavefront over the entire unsegmented pupil. The last approach is based on the pair-wise slaving of edge actuators and shows the best results. We compare the performance of these methods using realistic end-to-end simulations. We find that pair-wise slaving leads to a small increase of the total wavefront error, only adding between 20-45 nm RMS in quadrature for seeing conditions between 0.45-0.85 arcsec. Finally, we discuss the possibility of combining the different proposed solutions to increase robustness.
[4]  oai:arXiv.org:1809.09097  [pdf] - 1756099
Laboratory Demonstration of an Active Optics System for High-Resolution Deployable CubeSat
Comments: 15 pages, 19 figures, 4S Symposium, Conference Proceeding, Sorrento, Italy, May 28 - June 1, 2018
Submitted: 2018-09-24
In this paper we present HighRes: a laboratory demonstration of a 3U CubeSat with a deployable primary mirror that has the potential of achieving high-resolution imaging for Earth Observation. The system is based on a Cassegrain telescope with a segmented primary mirror composed of 4 petals that form an effective aperture of 300 mm. The design provides diffraction limited performance over the entire field-of-view and allows for a panchromatic ground-sampling distance of less than 1 m at an altitude of 350 km. The alignment and co-phasing of the mirror segments is performed by focal plane sharpening and is validated through rigorous numerical simulations. The opto-mechanical design of the prototype and its laboratory demonstration are described and measurements from the on-board metrology sensors are presented. This data verifies that the performance of the mirror deployment and manipulation systems is sufficient for co-phasing. In addition, it is shown that the mirrors can be driven to any target position with an accuracy of 25 nm using closed-loop feedback between the mirror motors and the on-board metrology.
[5]  oai:arXiv.org:1805.11931  [pdf] - 1691645
The adaptive optics modes for HARMONI: from Classical to Laser Assisted Tomographic AO
Comments: SPIE proceeding, 2016
Submitted: 2018-05-30
HARMONI is a visible and NIR integral field spectrograph, providing the E-ELT's core spectroscopic capability at first light. HARMONI will work at the diffraction limit of the E-ELT, thanks to a Classical and a Laser Tomographic AO system. In this paper, we present the system choices that have been made for these SCAO and LTAO modules. In particular, we describe the strategy developed for the different Wave-Front Sensors: pyramid for SCAO, the LGSWFS concept, the NGSWFS path, and the truth sensor capabilities. We present first potential implementations. And we asses the first system performance.