Normalized to: Schumann, M.
[1]
oai:arXiv.org:2006.09721 [pdf] - 2124928
Observation of Excess Electronic Recoil Events in XENON1T
Aprile, E.;
Aalbers, J.;
Agostini, F.;
Alfonsi, M.;
Althueser, L.;
Amaro, F. D.;
Antochi, V. C.;
Angelino, E.;
Angevaare, J. R.;
Arneodo, F.;
Barge, D.;
Baudis, L.;
Bauermeister, B.;
Bellagamba, L.;
Benabderrahmane, M. L.;
Berger, T.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Capelli, C.;
Cardoso, J. M. R.;
Cichon, D.;
Cimmino, B.;
Clark, M.;
Coderre, D.;
Colijn, A. P.;
Conrad, J.;
Cussonneau, J. P.;
Decowski, M. P.;
Depoian, A.;
Di Gangi, P.;
Di Giovanni, A.;
Di Stefano, R.;
Diglio, S.;
Elykov, A.;
Eurin, G.;
Ferella, A. D.;
Fulgione, W.;
Gaemers, P.;
Gaior, R.;
Galloway, M.;
Gao, F.;
Grandi, L.;
Hasterok, C.;
Hils, C.;
Hiraide, K.;
Hoetzsch, L.;
Howlett, J.;
Iacovacci, M.;
Itow, Y.;
Joerg, F.;
Kato, N.;
Kazama, S.;
Kobayashi, M.;
Koltman, G.;
Kopec, A.;
Landsman, H.;
Lang, R. F.;
Levinson, L.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lombardi, F.;
Long, J.;
Lopes, J. A. M.;
Fune, E. López;
Macolino, C.;
Mahlstedt, J.;
Mancuso, A.;
Manenti, L.;
Manfredini, A.;
Marignetti, F.;
Undagoitia, T. Marrodán;
Martens, K.;
Masbou, J.;
Masson, D.;
Mastroianni, S.;
Messina, M.;
Miuchi, K.;
Mizukoshi, K.;
Molinario, A.;
Morå, K.;
Moriyama, S.;
Mosbacher, Y.;
Murra, M.;
Naganoma, J.;
Ni, K.;
Oberlack, U.;
Odgers, K.;
Palacio, J.;
Pelssers, B.;
Peres, R.;
Pienaar, J.;
Pizzella, V.;
Plante, G.;
Qin, J.;
Qiu, H.;
García, D. Ramírez;
Reichard, S.;
Rocchetti, A.;
Rupp, N.;
Santos, J. M. F. dos;
Sartorelli, G.;
Šarčević, N.;
Scheibelhut, M.;
Schreiner, J.;
Schulte, D.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Semeria, F.;
Shagin, P.;
Shockley, E.;
Silva, M.;
Simgen, H.;
Takeda, A.;
Therreau, C.;
Thers, D.;
Toschi, F.;
Trinchero, G.;
Tunnell, C.;
Vargas, M.;
Volta, G.;
Wang, H.;
Wei, Y.;
Weinheimer, C.;
Weiss, M.;
Wenz, D.;
Wittweg, C.;
Xu, Z.;
Yamashita, M.;
Ye, J.;
Zavattini, G.;
Zhang, Y.;
Zhu, T.;
Zopounidis, J. P.;
Mougeot, X.
Submitted: 2020-06-17, last modified: 2020-06-30
We report results from searches for new physics with low-energy electronic
recoil data recorded with the XENON1T detector, with an exposure of 0.65 t-y
and an unprecedentedly low background rate of $76 \pm 2_{stat}$ events/(t y
keV) between 1-30 keV. An excess over known backgrounds is observed below 7
keV, rising towards lower energies and prominent between 2-3 keV. The solar
axion model has a 3.5$\sigma$ significance, and a three-dimensional 90%
confidence surface is reported for axion couplings to electrons, photons, and
nucleons. This surface is inscribed in the cuboid defined by $g_{ae} < 3.7
\times 10^{-12}$, $g_{ae}g_{an}^{eff} < 4.6 \times 10^{-18}$, and
$g_{ae}g_{a\gamma} < 7.6\times10^{-22}~{GeV}^{-1}$, and excludes either
$g_{ae}=0$ or $g_{ae}g_{a\gamma}=g_{ae}g_{an}^{eff}=0$. The neutrino magnetic
moment signal is similarly favored over background at 3.2$\sigma$ and a
confidence interval of $\mu_{\nu} \in (1.4,~2.9)\times10^{-11}\mu_B$ (90% C.L.)
is reported. Both results are in strong tension with stellar constraints. The
excess can also be explained by $\beta$ decays of tritium at 3.2$\sigma$
significance with a corresponding tritium concentration in xenon of $(6.2 \pm
2.0) \times 10^{-25}$ mol/mol. Such a trace amount can be neither confirmed nor
excluded with current knowledge of production and reduction mechanisms. The
significances of the solar axion and neutrino magnetic moment hypotheses are
decreased to 2.1$\sigma$ and 0.9$\sigma$, respectively, if an unconstrained
tritium component is included in the fitting. With respect to bosonic dark
matter, the excess favors a monoenergetic peak at ($2.3 \pm 0.2$) keV (68%
C.L.) with a 3.0$\sigma$ global (4.0$\sigma$ local) significance over
background. This analysis sets the most restrictive direct constraints to date
on pseudoscalar and vector bosonic dark matter for most masses between 1 and
210 keV/c$^2$.
[2]
oai:arXiv.org:2006.03114 [pdf] - 2109247
Solar Neutrino Detection Sensitivity in DARWIN via Electron Scattering
Aalbers, J.;
Agostini, F.;
Maouloud, S. E. M. Ahmed;
Alfonsi, M.;
Althueser, L.;
Amaro, F.;
Angevaare, J.;
Antochi, V. C.;
Antunovic, B.;
Aprile, E.;
Arazi, L.;
Arneodo, F.;
Balzer, M.;
Baudis, L.;
Baur, D.;
Benabderrahmane, M. L.;
Biondi, Y.;
Bismark, A.;
Bourgeois, C.;
Breskin, A.;
Breur, P. A.;
Brown, A.;
Brown, E.;
Bruno, G.;
Brünner, S.;
Bruno, G.;
Budnik, R.;
Capelli, C.;
Cardoso, J.;
Cichon, D.;
Clark, M.;
Colijn, A. P.;
Conrad, J.;
Cuenca-García, J. J.;
Cussonneau, J. P.;
Decowski, M. P.;
Depoian, A.;
Dierle, J.;
Di Gangi, P.;
Di Giovanni, A.;
Diglio, S.;
Douillet, D.;
Drexlin, G.;
Eitel, K.;
Engel, R.;
Erdal, E.;
Ferella, A. D.;
Fischer, H.;
Fischer, P.;
Fulgione, W.;
Gaemers, P.;
Galloway, M.;
Gao, F.;
Giovagnoli, D.;
Girard, F.;
Glade-Beucke, R.;
Glück, F.;
Grandi, L.;
Grohmann, S.;
Größle, R.;
Gumbsheimer, R.;
Hannen, V.;
Hansmann-Menzemer, S.;
Hils, C.;
Holzapfel, B.;
Howlett, J.;
Iaquaniello, G.;
Jörg, F.;
Keller, M.;
Kellerer, J.;
Khundzakishvili, G.;
Kilminster, B.;
Kleifges, M.;
Kleiner, T. K.;
Koltmann, G.;
Kopec, A.;
Kopmann, A.;
Krauss, L. M.;
Kuger, F.;
LaCascio, L.;
Landsman, H.;
Lang, R. F.;
Lindemann, S.;
Lindner, M.;
Lombardi, F.;
Lopes, J. A. M.;
Villalpando, A. Loya;
Ma, Y.;
Macolino, C.;
Mahlstedt, J.;
Manfredini, A.;
Undagoitia, T. Marrodán;
Masbou, J.;
Masson, D.;
Masson, E.;
McFadden, N.;
Meinhardt, P.;
Meyer, R.;
Milosevic, B.;
Milutinovic, S.;
Molinario, A.;
Monteiro, C. M. B.;
Morå, K.;
Morteau, E.;
Mosbacher, Y.;
Murra, M.;
Newstead, J. L.;
Ni, K.;
Oberlack, U. G.;
Obradovic, M.;
Odgers, K.;
Ostrovskiy, I.;
Palacio, J.;
Pandurovic, M.;
Pelssers, B.;
Peres, R.;
Pienaar, J.;
Pierre, M.;
Pizzella, V.;
Plante, G.;
Qi, J.;
Qin, J.;
García, D. Ramírez;
Reichard, S. E.;
Rupp, N.;
Sanchez-Lucas, P.;
Santos, J.;
Sartorelli, G.;
Schulte, D.;
Schultz-Coulon, H. -C.;
Eißing, H. Schulze;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Shagin, P.;
Sharma, S.;
Shen, W.;
Silva, M.;
Simgen, H.;
Steidl, M.;
Stern, S.;
Subotic, D.;
Szabo, P.;
Terliuk, A.;
Therreau, C.;
Thers, D.;
Thieme, K.;
Toennies, F.;
Trotta, R.;
Tunnell, C. D.;
Valerius, K.;
Volta, G.;
Vorkapic, D.;
Weber, M.;
Wei, Y.;
Weinheimer, C.;
Weiss, M.;
Wenz, D.;
Wittweg, C.;
Wolf, J.;
Wuestling, S.;
Wurm, M.;
Xing, Y.;
Zhu, T.;
Zhu, Y.;
Zopounidis, J. P.;
Zuber, K.
Submitted: 2020-06-04
We detail the sensitivity of the liquid xenon (LXe) DARWIN observatory to
solar neutrinos via elastic electron scattering. We find that DARWIN will have
the potential to measure the fluxes of five solar neutrino components: $pp$,
$^7$Be, $^{13}$N, $^{15}$O and $pep$. The precision of the $^{13}$N, $^{15}$O
and $pep$ components is hindered by the double-beta decay of $^{136}$Xe and,
thus, would benefit from a depleted target. A high-statistics observation of
$pp$ neutrinos would allow us to infer the values of the weak mixing angle,
$\sin^2\theta_w$, and the electron-type neutrino survival probability, $P_e$,
in the electron recoil energy region from a few keV up to 200 keV for the first
time, with relative precision of 5% and 4%, respectively, at an exposure of 300
ty. An observation of $pp$ and $^7$Be neutrinos would constrain the
neutrino-inferred solar luminosity down to 0.2%. A combination of all flux
measurements would distinguish between the high (GS98) and low metallicity
(AGS09) solar models with 2.1-2.5$\sigma$ significance, independent of external
measurements from other experiments or a measurement of $^8$B neutrinos through
coherent elastic neutrino-nucleus scattering in DARWIN. Finally, we demonstrate
that with a depleted target DARWIN may be sensitive to the neutrino capture
process of $^{131}$Xe.
[3]
oai:arXiv.org:2003.03825 [pdf] - 2060953
Energy resolution and linearity in the keV to MeV range measured in
XENON1T
Aprile, E.;
Aalbers, J.;
Agostini, F.;
Alfonsi, M.;
Althueser, L.;
Amaro, F. D.;
Antochi, V. C.;
Angelino, E.;
Angevaare, J.;
Arneodo, F.;
Barge, D.;
Baudis, L.;
Bauermeister, B.;
Bellagamba, L.;
Benabderrahmane, M. L.;
Berger, T.;
Breur, P. A.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Capelli, C.;
Cardoso, J. M. R.;
Cichon, D.;
Cimmino, B.;
Clark, M.;
Coderre, D.;
Colijn, A. P.;
Conrad, J.;
Cussonneau, J. P.;
Decowski, M. P.;
Di Stefano, A. Depoian P. Di Gangi A. Di Giovanni R.;
Diglio, S.;
Elykov, A.;
Eurin, G.;
Ferella, A. D.;
Fulgione, W.;
Gaemers, P.;
Gaior, R.;
Rosso, A. Gallo;
Galloway, M.;
Gao, F.;
Garbini, M.;
Grandi, L.;
Hasterok, C.;
Hils, C.;
Hiraide, K.;
Hoetzsch, L.;
Hogenbirk, E.;
Howlett, J.;
Iacovacci, M.;
Itow, Y.;
Joerg, F.;
Kato, N.;
Kazama, S.;
Kobayashi, M.;
Koltman, G.;
Kopec, A.;
Landsman, H.;
Lang, R. F.;
Levinson, L.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lombardi, F.;
Lopes, J. A. M.;
Fune, E. López;
Macolino, C.;
Mahlstedt, J.;
Manenti, L.;
Manfredini, A.;
Marignetti, F.;
Undagoitia, T. Marrodán;
Martens, K.;
Masbou, J.;
Masson, D.;
Mastroianni, S.;
Messina, M.;
Miuchi, K.;
Molinario, A.;
Morå, K.;
Moriyama, S.;
Mosbacher, Y.;
Murra, M.;
Naganoma, J.;
Ni, K.;
Oberlack, U.;
Odgers, K.;
Palacio, J.;
Pelssers, B.;
Peres, R.;
Pienaar, J.;
Pizzella, V.;
Qin, G. Plante J.;
Qiu, H.;
García, D. Ramírez;
Reichard, S.;
Rocchetti, A.;
Rupp, N.;
Santos, J. M. F. dos;
Sartorelli, G.;
Šarčević, N.;
Scheibelhut, M.;
Schindler, S.;
Schreiner, J.;
Schulte, D.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Semeria, F.;
Shagin, P.;
Shockley, E.;
Silva, M.;
Simgen, H.;
Takeda, A.;
Therreau, C.;
Thers, D.;
Toschi, F.;
Trinchero, G.;
Tunnell, C.;
Vargas, M.;
Volta, G.;
Wack, O.;
Wang, H.;
Wei, Y.;
Weinheimer, C.;
Xu, M. Weiss;
Wenz, D.;
Wittweg, C.;
Wulf, J.;
Xu, Z.;
Yamashita, M.;
Ye, J.;
Zavattini, G.;
Zhang, Y.;
Zhu, T.;
Zopounidis, J. P.
Submitted: 2020-03-08
Xenon dual-phase time projection chambers designed to search for Weakly
Interacting Massive Particles have so far shown a relative energy resolution
which degrades with energy above $\sim$200 keV. This has limited their
sensitivity in the search for rare events like the neutrinoless double-beta
decay of $^{136}$Xe at its $Q$-value, $Q_{\beta\beta}\simeq$ 2.46 MeV. For the
XENON1T dual-phase time projection chamber, we demonstrate that the relative
energy resolution at 1 $\sigma/\mu$ is as low as (0.79$\pm$0.02) % in its
one-ton fiducial mass, and for single-site interactions at $Q_{\beta\beta}$. We
achieve this by using a signal correction method to rectify the saturation
effects of the signal readout system. The very good energy resolution from keV
to MeV energies demonstrated in XENON1T opens up new windows for the xenon
dual-phase dark matter detectors to simultaneously search for other rare
events.
[4]
oai:arXiv.org:1907.12771 [pdf] - 2021183
Search for Light Dark Matter Interactions Enhanced by the Migdal effect
or Bremsstrahlung in XENON1T
Aprile, E.;
Aalbers, J.;
Agostini, F.;
Alfonsi, M.;
Althueser, L.;
Amaro, F. D.;
Antochi, V. C.;
Angelino, E.;
Arneodo, F.;
Barge, D.;
Baudis, L.;
Bauermeister, B.;
Bellagamba, L.;
Benabderrahmane, M. L.;
Berger, T.;
Breur, P. A.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Capelli, C.;
Cardoso, J. M. R.;
Cichon, D.;
Coderre, D.;
Colijn, A. P.;
Conrad, J.;
Cussonneau, J. P.;
Decowski, M. P.;
de Perio, P.;
Depoian, A.;
Di Gangi, P.;
Di Giovanni, A.;
Diglio, S.;
Elykov, A.;
Eurin, G.;
Fei, J.;
Ferella, A. D.;
Fieguth, A.;
Fulgione, W.;
Gaemers, P.;
Rosso, A. Gallo;
Galloway, M.;
Gao, F.;
Garbini, M.;
Grandi, L.;
Greene, Z.;
Hasterok, C.;
Hils, C.;
Hogenbirk, E.;
Howlett, J.;
Iacovacci, M.;
Itay, R.;
Joerg, F.;
Kazama, S.;
Kish, A.;
Kobayashi, M.;
Koltman, G.;
Kopec, A.;
Landsman, H.;
Lang, R. F.;
Levinson, L.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lombardi, F.;
Lopes, J. A. M.;
Fune, E. López;
Macolino, C.;
Mahlstedt, J.;
Manenti, L.;
Manfredini, A.;
Marignetti, F.;
Undagoitia, T. Marrodán;
Masbou, J.;
Mastroianni, S.;
Messina, M.;
Micheneau, K.;
Miller, K.;
Molinario, A.;
Morå, K.;
Mosbacher, Y.;
Murra, M.;
Naganoma, J.;
Ni, K.;
Oberlack, U.;
Odgers, K.;
Palacio, J.;
Pelssers, B.;
Peres, R.;
Pienaar, J.;
Pizzella, V.;
Plante, G.;
Podviianiuk, R.;
Qin, J.;
Qiu, H.;
García, D. Ramírez;
Reichard, S.;
Riedel, B.;
Rocchetti, A.;
Rupp, N.;
Santos, J. M. F. dos;
Sartorelli, G.;
Šarčević, N.;
Scheibelhut, M.;
Schindler, S.;
Schreiner, J.;
Schulte, D.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Shagin, P.;
Shockley, E.;
Silva, M.;
Simgen, H.;
Therreau, C.;
Thers, D.;
Toschi, F.;
Trinchero, G.;
Tunnell, C.;
Upole, N.;
Vargas, M.;
Volta, G.;
Wack, O.;
Wang, H.;
Wei, Y.;
Weinheimer, C.;
Wenz, D.;
Wittweg, C.;
Wulf, J.;
Ye, J.;
Zhang, Y.;
Zhu, T.;
Zopounidis, J. P.
Submitted: 2019-07-30, last modified: 2019-12-24
Direct dark matter detection experiments based on a liquid xenon target are
leading the search for dark matter particles with masses above $\sim$ 5
GeV/c$^2$, but have limited sensitivity to lighter masses because of the small
momentum transfer in dark matter-nucleus elastic scattering. However, there is
an irreducible contribution from inelastic processes accompanying the elastic
scattering, which leads to the excitation and ionization of the recoiling atom
(the Migdal effect) or the emission of a Bremsstrahlung photon. In this letter,
we report on a probe of low-mass dark matter with masses down to about 85
MeV/c$^2$ by looking for electronic recoils induced by the Migdal effect and
Bremsstrahlung, using data from the XENON1T experiment. Besides the approach of
detecting both scintillation and ionization signals, we exploit an approach
that uses ionization signals only, which allows for a lower detection
threshold. This analysis significantly enhances the sensitivity of XENON1T to
light dark matter previously beyond its reach.
[5]
oai:arXiv.org:1907.11485 [pdf] - 2015750
Light Dark Matter Search with Ionization Signals in XENON1T
Aprile, E.;
Aalbers, J.;
Agostini, F.;
Alfonsi, M.;
Althueser, L.;
Amaro, F. D.;
Antochi, V. C.;
Angelino, E.;
Arneodo, F.;
Barge, D.;
Baudis, L.;
Bauermeister, B.;
Bellagamba, L.;
Benabderrahmane, M. L.;
Berger, T.;
Breur, P. A.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Capelli, C.;
Cardoso, J. M. R.;
Cichon, D.;
Coderre, D.;
Colijn, A. P.;
Conrad, J.;
Cussonneau, J. P.;
Decowski, M. P.;
de Perio, P.;
Depoian, A.;
Di Gangi, P.;
Di Giovanni, A.;
Diglio, S.;
Elykov, A.;
Eurin, G.;
Fei, J.;
Ferella, A. D.;
Fieguth, A.;
Fulgione, W.;
Gaemers, P.;
Rosso, A. Gallo;
Galloway, M.;
Gao, F.;
Garbini, M.;
Grandi, L.;
Greene, Z.;
Hasterok, C.;
Hils, C.;
Hogenbirk, E.;
Howlett, J.;
Iacovacci, M.;
Itay, R.;
Joerg, F.;
Kazama, S.;
Kish, A.;
Kobayashi, M.;
Koltman, G.;
Kopec, A.;
Landsman, H.;
Lang, R. F.;
Levinson, L.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lombardi, F.;
Lopes, J. A. M.;
Fune, E. López;
Macolino, C.;
Mahlstedt, J.;
Manfredini, A.;
Marignetti, F.;
Undagoitia, T. Marrodán;
Masbou, J.;
Mastroianni, S.;
Messina, M.;
Micheneau, K.;
Miller, K.;
Molinario, A.;
Morå, K.;
Mosbacher, Y.;
Murra, M.;
Naganoma, J.;
Ni, K.;
Oberlack, U.;
Odgers, K.;
Palacio, J.;
Pelssers, B.;
Peres, R.;
Pienaar, J.;
Pizzella, V.;
Plante, G.;
Podviianiuk, R.;
Qin, J.;
Qiu, H.;
García, D. Ramírez;
Reichard, S.;
Riedel, B.;
Rocchetti, A.;
Rupp, N.;
Santos, J. M. F. dos;
Sartorelli, G.;
Šarčević, N.;
Scheibelhut, M.;
Schindler, S.;
Schreiner, J.;
Schulte, D.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Shagin, P.;
Shockley, E.;
Silva, M.;
Simgen, H.;
Therreau, C.;
Thers, D.;
Toschi, F.;
Trinchero, G.;
Tunnell, C.;
Upole, N.;
Vargas, M.;
Volta, G.;
Wack, O.;
Wang, H.;
Wei, Y.;
Weinheimer, C.;
Wenz, D.;
Wittweg, C.;
Wulf, J.;
Ye, J.;
Zhang, Y.;
Zhu, T.;
Zopounidis, J. P.
Submitted: 2019-07-26, last modified: 2019-12-17
We report constraints on light dark matter (DM) models using ionization
signals in the XENON1T experiment. We mitigate backgrounds with strong event
selections, rather than requiring a scintillation signal, leaving an effective
exposure of $(22 \pm 3)$ tonne-days. Above
$\sim\!0.4\,\mathrm{keV}_\mathrm{ee}$, we observe $<1 \,
\text{event}/(\text{tonne} \times \text{day} \times \text{keV}_\text{ee})$,
which is more than one thousand times lower than in similar searches with other
detectors. Despite observing a higher rate at lower energies, no DM or CEvNS
detection may be claimed because we cannot model all of our backgrounds. We
thus exclude new regions in the parameter spaces for DM-nucleus scattering for
DM masses $m_\chi$ within $3-6\,\mathrm{GeV}/\mathrm{c}^2$, DM-electron
scattering for $m_\chi > 30\,\mathrm{MeV}/\mathrm{c}^2$, and absorption of dark
photons and axion-like particles for $m_\chi$ within $0.186 - 1 \,
\mathrm{keV}/\mathrm{c}^2$.
[6]
oai:arXiv.org:1903.03026 [pdf] - 2002943
Direct Detection of WIMP Dark Matter: Concepts and Status
Submitted: 2019-03-07, last modified: 2019-07-04
The existence of dark matter as evidenced by numerous indirect observations
is one of the most important indications that there must be physics beyond the
Standard Model of particle physics. This article reviews the concepts of direct
detection of dark matter in the form of Weakly Interacting Massive Particles
(WIMPs) in ultra-sensitive detectors located in underground laboratories,
discusses the expected signatures, detector concepts, and how the stringent
low-background requirements are achieved. Finally, it summarizes the current
status of the field and provides an outlook on the years to come.
[7]
oai:arXiv.org:1906.01084 [pdf] - 1894436
First Results on the Search for Chameleons with the KWISP Detector at
CAST
Cuendis, S. Arguedas;
Baier, J.;
Barth, K.;
Baum, S.;
Bayirli, A.;
Belov, A.;
Bräuninger, H.;
Cantatore, G.;
Carmona, J. M.;
Castel, J. F.;
Cetin, S. A.;
Dafni, T.;
Davenport, M.;
Dermenev, A.;
Desch, K.;
Döbrich, B.;
Fischer, H.;
Funk, W.;
García, J. A.;
Gardikiotis, A.;
Garza, J. G.;
Gninenko, S.;
Hasinoff, M. D.;
Hoffmann, D. H. H.;
Iguaz, F. J.;
Irastorza, I. G.;
Jakovčić, K.;
Kaminski, J.;
Karuza, M.;
Krieger, C.;
Lakić, B.;
Laurent, J. M.;
Luzón, G.;
Maroudas, M.;
Miceli, L.;
Neff, S.;
Ortega, I.;
Ozbey, A.;
Pivovaroff, M. J.;
Rosu, M.;
Ruz, J.;
Chóliz, E. Ruiz;
Schmidt, S.;
Schumann, M.;
Semertzidis, Y. K.;
Solanki, S. K.;
Stewart, L.;
Tsagris, I.;
Vafeiadis, T.;
Vogel, J. K.;
Vretenar, M.;
Yildiz, S. C.;
Zioutas, K.
Submitted: 2019-06-03
We report on a first measurement with a sensitive opto-mechanical force
sensor designed for the direct detection of coupling of real chameleons to
matter. These dark energy candidates could be produced in the Sun and stream
unimpeded to Earth. The KWISP detector installed on the CAST axion search
experiment at CERN looks for tiny displacements of a thin membrane caused by
the mechanical effect of solar chameleons. The displacements are detected by a
Michelson interferometer with a homodyne readout scheme. The sensor benefits
from the focusing action of the ABRIXAS X-ray telescope installed at CAST,
which increases the chameleon flux on the membrane. A mechanical chopper placed
between the telescope output and the detector modulates the incoming chameleon
stream. We present the results of the solar chameleon measurements taken at
CAST in July 2017, setting an upper bound on the force acting on the membrane
of $80$~pN at 95\% confidence level. The detector is sensitive for direct
coupling to matter $10^4 \leq\beta_m \leq 10^8$, where the coupling to photons
is locally bound to $\beta_\gamma \leq 10^{11}$.
[8]
oai:arXiv.org:1902.03234 [pdf] - 1875324
Constraining the Spin-Dependent WIMP-Nucleon Cross Sections with XENON1T
Aprile, E.;
Aalbers, J.;
Agostini, F.;
Alfonsi, M.;
Althueser, L.;
Amaro, F. D.;
Anthony, M.;
Antochi, V. C.;
Arneodo, F.;
Baudis, L.;
Bauermeister, B.;
Benabderrahmane, M. L.;
Berger, T.;
Breur, P. A.;
Brown, A.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Capelli, C.;
Cardoso, J. M. R.;
Cichon, D.;
Coderre, D.;
Colijn, A. P.;
Conrad, J.;
Cussonneau, J. P.;
Decowski, M. P.;
de Perio, P.;
Di Gangi, P.;
Di Giovanni, A.;
Diglio, S.;
Elykov, A.;
Eurin, G.;
Fei, J.;
Ferella, A. D.;
Fieguth, A.;
Fulgione, W.;
Rosso, A. Gallo;
Galloway, M.;
Gao, F.;
Garbini, M.;
Grandi, L.;
Greene, Z.;
Hasterok, C.;
Hogenbirk, E.;
Howlett, J.;
Iacovacci, M.;
Itay, R.;
Joerg, F.;
Kazama, S.;
Kish, A.;
Koltman, G.;
Kopec, A.;
Landsman, H.;
Lang, R. F.;
Levinson, L.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lombardi, F.;
Lopes, J. A. M.;
Fune, E. López;
Macolino, C.;
Mahlstedt, J.;
Manfredini, A.;
Marignetti, F.;
Undagoitia, T. Marrodán;
Masbou, J.;
Masson, D.;
Mastroianni, S.;
Messina, M.;
Micheneau, K.;
Miller, K.;
Molinario, A.;
Morå, K.;
Mosbacher, Y.;
Murra, M.;
Naganoma, J.;
Ni, K.;
Oberlack, U.;
Odgers, K.;
Pelssers, B.;
Piastra, F.;
Pienaar, J.;
Pizzella, V.;
Plante, G.;
Podviianiuk, R.;
Priel, N.;
Qiu, H.;
García, D. Ramírez;
Reichard, S.;
Riedel, B.;
Rizzo, A.;
Rocchetti, A.;
Rupp, N.;
Santos, J. M. F. dos;
Sartorelli, G.;
Šarčević, N.;
Scheibelhut, M.;
Schindler, S.;
Schreiner, J.;
Schulte, D.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Shagin, P.;
Shockley, E.;
Silva, M.;
Simgen, H.;
Therreau, C.;
Thers, D.;
Toschi, F.;
Trinchero, G.;
Tunnell, C.;
Upole, N.;
Vargas, M.;
Wack, O.;
Wang, H.;
Wang, Z.;
Wei, Y.;
Weinheimer, C.;
Wenz, D.;
Wittweg, C.;
Wulf, J.;
Xu, Z.;
Ye, J.;
Zhang, Y.;
Zhu, T.;
Zopounidis, J. P.
Submitted: 2019-02-08, last modified: 2019-04-30
We report the first experimental results on spin-dependent elastic weakly
interacting massive particle (WIMP) nucleon scattering from the XENON1T dark
matter search experiment. The analysis uses the full ton year exposure of
XENON1T to constrain the spin-dependent proton-only and neutron-only cases. No
significant signal excess is observed, and a profile likelihood ratio analysis
is used to set exclusion limits on the WIMP-nucleon interactions. This includes
the most stringent constraint to date on the WIMP-neutron cross section, with a
minimum of $6.3\times10^{-42}$ cm$^2$ at 30 GeV/c${}^2$ and 90% confidence
level. The results are compared with those from collider searches and used to
exclude new parameter space in an isoscalar theory with an axial-vector
mediator.
[9]
oai:arXiv.org:1811.12482 [pdf] - 1836537
First results on the scalar WIMP-pion coupling, using the XENON1T
experiment
Aprile, E.;
Aalbers, J.;
Agostini, F.;
Alfonsi, M.;
Althueser, L.;
Amaro, F. D.;
Anthony, M.;
Antochi, V. C.;
Arneodo, F.;
Baudis, L.;
Bauermeister, B.;
Benabderrahmane, M. L.;
Berger, T.;
Breur, P. A.;
Brown, A.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Capelli, C.;
Cardoso, J. M. R.;
Cichon, D.;
Coderre, D.;
Colijn, A. P.;
Conrad, J.;
Cussonneau, J. P.;
Decowski, M. P.;
de Perio, P.;
Di Gangi, P.;
Di Giovanni, A.;
Diglio, S.;
Elykov, A.;
Eurin, G.;
Fei, J.;
Ferella, A. D.;
Fieguth, A.;
Fulgione, W.;
Rosso, A. Gallo;
Galloway, M.;
Gao, F.;
Garbini, M.;
Grandi, L.;
Greene, Z.;
Hasterok, C.;
Hogenbirk, E.;
Howlett, J.;
Iacovacci, M.;
Itay, R.;
Joerg, F.;
Kaminsky, B.;
Kazama, S.;
Kish, A.;
Koltman, G.;
Kopec, A.;
Landsman, H.;
Lang, R. F.;
Levinson, L.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lombardi, F.;
Lopes, J. A. M.;
Fune, E. López;
Macolino, C.;
Mahlstedt, J.;
Manfredini, A.;
Marignetti, F.;
Undagoitia, T. Marrodán;
Masbou, J.;
Masson, D.;
Mastroianni, S.;
Messina, M.;
Micheneau, K.;
Miller, K.;
Molinario, A.;
Morå, K.;
Murra, M.;
Naganoma, J.;
Ni, K.;
Oberlack, U.;
Odgers, K.;
Pelssers, B.;
Piastra, F.;
Pienaar, J.;
Pizzella, V.;
Plante, G.;
Podviianiuk, R.;
Priel, N.;
Qiu, H.;
García, D. Ramírez;
Reichard, S.;
Riedel, B.;
Rizzo, A.;
Rocchetti, A.;
Rupp, N.;
Santos, J. M. F. dos;
Sartorelli, G.;
Šarčević, N.;
Scheibelhut, M.;
Schindler, S.;
Schreiner, J.;
Schulte, D.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Shagin, P.;
Shockley, E.;
Silva, M.;
Simgen, H.;
Therreau, C.;
Thers, D.;
Toschi, F.;
Trinchero, G.;
Tunnell, C.;
Upole, N.;
Vargas, M.;
Wack, O.;
Wang, H.;
Wang, Z.;
Wei, Y.;
Weinheimer, C.;
Wittweg, C.;
Wulf, J.;
Ye, J.;
Zhang, Y.;
Zhu, T.;
Zopounidis, J. P.;
Hoferichter, M.;
Klos, P.;
Menéndez, J.;
Schwenk, A.
Submitted: 2018-11-29, last modified: 2019-02-22
We present first results on the scalar WIMP-pion coupling from 1 t$\times$yr
of exposure with the XENON1T experiment. This interaction is generated when the
WIMP couples to a virtual pion exchanged between the nucleons in a nucleus. In
contrast to most non-relativistic operators, these pion-exchange currents can
be coherently enhanced by the total number of nucleons, and therefore may
dominate in scenarios where spin-independent WIMP-nucleon interactions are
suppressed. Moreover, for natural values of the couplings, they dominate over
the spin-dependent channel due to their coherence in the nucleus. Using the
signal model of this new WIMP-pion channel, no significant excess is found,
leading to an upper limit cross section of $6.4\times10^{-46}$ cm$^2$ (90 %
confidence level) at 30 GeV/c$^2$ WIMP mass.
[10]
oai:arXiv.org:1806.03202 [pdf] - 1771565
No correlation between Solar flares and the decay rate of several
$\beta$-decaying isotopes
Angevaare, J. R.;
Baudis, L.;
Breur, P. A.;
Brown, A.;
Colijn, A. P.;
Lang, R. F.;
Massafferri, A.;
Nobelen, J. C. P. Y.;
Perci, R.;
Reuter, C.;
Schumann, M.
Submitted: 2018-06-08, last modified: 2018-10-23
We report on finding no correlation between the two strongest observed Solar
flares in September 2017 and the decay rates of $^{60}$Co, $^{44}$Ti and
$^{137}$Cs sources, which are continuously measured by two independent NaI(Tl)
detector setups. We test for variations in the number of observed counts with
respect to the number of expected counts over multiple periods with timescales
varying from 1 to 109 hours around the Solar flare. No excess or deficit
exceeds the 2$\sigma$ global significance. We set a conservative lower limit on
the decay rate deviation over an 84-hour period around the two correlated Solar
flares in September 2017 to $0.044\%$ with 2$\sigma$ confidence. A fractional
change of $~0.1\%$ in the decay rate of $^{54}$Mn over a period of 84 hours was
claimed with 7$\sigma$ significance during multiple Solar flares in December
2006. We exclude such an effect at 4.7$\sigma$ significance.
[11]
oai:arXiv.org:1805.12562 [pdf] - 1749718
Dark Matter Search Results from a One Tonne$\times$Year Exposure of
XENON1T
Aprile, E.;
Aalbers, J.;
Agostini, F.;
Alfonsi, M.;
Althueser, L.;
Amaro, F. D.;
Anthony, M.;
Arneodo, F.;
Baudis, L.;
Bauermeister, B.;
Benabderrahmane, M. L.;
Berger, T.;
Breur, P. A.;
Brown, A.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Capelli, C.;
Cardoso, J. M. R.;
Cichon, D.;
Coderre, D.;
Colijn, A. P.;
Conrad, J.;
Cussonneau, J. P.;
Decowski, M. P.;
de Perio, P.;
Di Gangi, P.;
Di Giovanni, A.;
Diglio, S.;
Elykov, A.;
Eurin, G.;
Fei, J.;
Ferella, A. D.;
Fieguth, A.;
Fulgione, W.;
Rosso, A. Gallo;
Galloway, M.;
Gao, F.;
Garbini, M.;
Geis, C.;
Grandi, L.;
Greene, Z.;
Qiu, H.;
Hasterok, C.;
Hogenbirk, E.;
Howlett, J.;
Itay, R.;
Joerg, F.;
Kaminsky, B.;
Kazama, S.;
Kish, A.;
Koltman, G.;
Landsman, H.;
Lang, R. F.;
Levinson, L.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lombardi, F.;
Lopes, J. A. M.;
Mahlstedt, J.;
Manfredini, A.;
Undagoitia, T. Marrodán;
Masbou, J.;
Masson, D.;
Messina, M.;
Micheneau, K.;
Miller, K.;
Molinario, A.;
Morå, K.;
Murra, M.;
Naganoma, J.;
Ni, K.;
Oberlack, U.;
Pelssers, B.;
Piastra, F.;
Pienaar, J.;
Pizzella, V.;
Plante, G.;
Podviianiuk, R.;
Priel, N.;
García, D. Ramírez;
Rauch, L.;
Reichard, S.;
Reuter, C.;
Riedel, B.;
Rizzo, A.;
Rocchetti, A.;
Rupp, N.;
Santos, J. M. F. dos;
Sartorelli, G.;
Scheibelhut, M.;
Schindler, S.;
Schreiner, J.;
Schulte, D.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Shagin, P.;
Shockley, E.;
Silva, M.;
Simgen, H.;
Thers, D.;
Toschi, F.;
Trinchero, G.;
Tunnell, C.;
Upole, N.;
Vargas, M.;
Wack, O.;
Wang, H.;
Wang, Z.;
Wei, Y.;
Weinheimer, C.;
Wittweg, C.;
Wulf, J.;
Ye, J.;
Zhang, Y.;
Zhu, T.
Submitted: 2018-05-31, last modified: 2018-09-13
We report on a search for Weakly Interacting Massive Particles (WIMPs) using
278.8 days of data collected with the XENON1T experiment at LNGS. XENON1T
utilizes a liquid xenon time projection chamber with a fiducial mass of $(1.30
\pm 0.01)$ t, resulting in a 1.0 t$\times$yr exposure. The energy region of
interest, [1.4, 10.6] $\mathrm{keV_{ee}}$ ([4.9, 40.9] $\mathrm{keV_{nr}}$),
exhibits an ultra-low electron recoil background rate of $(82\substack{+5 \\
-3}\textrm{ (sys)}\pm3\textrm{ (stat)})$
events/$(\mathrm{t}\times\mathrm{yr}\times\mathrm{keV_{ee}})$. No significant
excess over background is found and a profile likelihood analysis parameterized
in spatial and energy dimensions excludes new parameter space for the
WIMP-nucleon spin-independent elastic scatter cross-section for WIMP masses
above 6 GeV/c${}^2$, with a minimum of $4.1\times10^{-47}$ cm$^2$ at 30
GeV/c${}^2$ and 90% confidence level.
[12]
oai:arXiv.org:1708.03617 [pdf] - 1644121
Intrinsic backgrounds from Rn and Kr in the XENON100 experiment
XENON Collaboration;
Aprile, E.;
Aalbers, J.;
Agostini, F.;
Alfonsi, M.;
Amaro, F. D.;
Anthony, M.;
Arneodo, F.;
Barrow, P.;
Baudis, L.;
Bauermeister, B.;
Benabderrahmane, M. L.;
Berger, T.;
Breur, P. A.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Bütikofer, L.;
Calvén, J.;
Cardoso, J. M. R.;
Cervantes, M.;
Cichon, D.;
Coderre, D.;
Colijn, A. P.;
Conrad, J.;
Cussonneau, J. P.;
Decowski, M. P.;
de Perio, P.;
Di Gangi, P.;
Di Giovanni, A.;
Diglio, S.;
Eurin, G.;
Fei, J.;
Ferella, A. D.;
Fieguth, A.;
Fulgione, W.;
Rosso, A. Gallo;
Galloway, M.;
Gao, F.;
Garbini, M.;
Geis, C.;
Goetzke, L. W.;
Greene, Z.;
Grignon, C.;
Hasterok, C.;
Hogenbirk, E.;
Itay, R.;
Kaminsky, B.;
Kazama, S.;
Kessler, G.;
Kish, A.;
Landsman, H.;
Lang, R. F.;
Lellouch, D.;
Levinson, L.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lombardi, F.;
Lopes, J. A. M.;
Manfredini, A.;
Maris, I.;
Undagoitia, T. Marrodán;
Masbou, J.;
Massoli, F. V.;
Masson, D.;
Mayani, D.;
Messina, M.;
Micheneau, K.;
Molinario, A.;
Morå, K.;
Murra, M.;
Naganoma, J.;
Ni, K.;
Oberlack, U.;
Pakarha, P.;
Pelssers, B.;
Persiani, R.;
Piastra, F.;
Pienaar, J.;
Piro, M. -C.;
Pizzella, V.;
Plante, G.;
Priel, N.;
García, D. Ramírez;
Rauch, L.;
Reichard, S.;
Reuter, C.;
Rizzo, A.;
Rupp, N.;
Santos, J. M. F. dos;
Sartorelli, G.;
Scheibelhut, M.;
Schindler, S.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Shagin, P.;
Silva, M.;
Simgen, H.;
Sivers, M. v.;
Stein, A.;
Thers, D.;
Tiseni, A.;
Trinchero, G.;
Tunnell, C.;
Vargas, M.;
Wang, H.;
Wang, Z.;
Weber, M.;
Wei, Y.;
Weinheimer, C.;
Wulf, J.;
Ye, J.;
Zhang, Y.
Submitted: 2017-08-11, last modified: 2018-03-03
In this paper, we describe the XENON100 data analyses used to assess the
target-intrinsic background sources radon ($^{222}$Rn), thoron ($^{220}$Rn) and
krypton ($^{85}$Kr). We detail the event selections of high-energy alpha
particles and decay-specific delayed coincidences. We derive distributions of
the individual radionuclides inside the detector and quantify their abundances
during the main three science runs of the experiment over a period of $\sim$ 4
years, from January 2010 to January 2014. We compare our results to external
measurements of radon emanation and krypton concentrations where we find good
agreement. We report an observed reduction in concentrations of radon daughters
that we attribute to the plating-out of charged ions on the negatively biased
cathode.
[13]
oai:arXiv.org:1709.10149 [pdf] - 1690301
Signal Yields of keV Electronic Recoils and Their Discrimination from
Nuclear Recoils in Liquid Xenon
Aprile, E.;
Aalbers, J.;
Agostini, F.;
Alfonsi, M.;
Amaro, F. D.;
Anthony, M.;
Arneodo, F.;
Barrow, P.;
Baudis, L.;
Bauermeister, B.;
Benabderrahmane, M. L.;
Berger, T.;
Breur, P. A.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Bütikofer, L.;
Calvén, J.;
Cardoso, J. M. R.;
Cervantes, M.;
Cichon, D.;
Coderre, D.;
Colijn, A. P.;
Conrad, J.;
Cussonneau, J. P.;
Decowski, M. P.;
de Perio, P.;
Di Gangi, P.;
Di Giovanni, A.;
Diglio, S.;
Eurin, G.;
Fei, J.;
Ferella, A. D.;
Fieguth, A.;
Fulgione, W.;
Rosso, A. Gallo;
Galloway, M.;
Gao, F.;
Garbini, M.;
Geis, C.;
Goetzke, L. W.;
Grandi, L.;
Greene, Z.;
Grignon, C.;
Hasterok, C.;
Hogenbirk, E.;
Itay, R.;
Kaminsky, B.;
Kazama, S.;
Kessler, G.;
Kish, A.;
Landsman, H.;
Lang, R. F.;
Lellouch, D.;
Levinson, L.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lombardi, F.;
Lopes, J. A. M.;
Manfredini, A.;
Maris, I.;
Undagoitia, T. Marrodán;
Masbou, J.;
Massoli, F. V.;
Masson, D.;
Mayani, D.;
Messina, M.;
Micheneau, K.;
Molinario, A.;
Morå, K.;
Murra, M.;
Naganoma, J.;
Ni, K.;
Oberlack, U.;
Pakarha, P.;
Pelssers, B.;
Persiani, R.;
Piastra, F.;
Pienaar, J.;
Pizzella, V.;
Piro, M. -C.;
Plante, G.;
Priel, N.;
García, D. Ramírez;
Rauch, L.;
Reichard, S.;
Reuter, C.;
Rizzo, A.;
Rupp, N.;
Saldanha, R.;
Santos, J. M. F. dos;
Sartorelli, G.;
Scheibelhut, M.;
Schindler, S.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Shagin, P.;
Shockley, E.;
Silva, M.;
Simgen, H.;
Sivers, M. v.;
Stein, A.;
Thers, D.;
Tiseni, A.;
Trinchero, G.;
Tunnell, C.;
Vargas, M.;
Wang, H.;
Wang, Z.;
Wei, Y.;
Weinheimer, C.;
Wulf, J.;
Ye, J.;
Zhang, Y.
Submitted: 2017-09-28, last modified: 2018-02-01
We report on the response of liquid xenon to low energy electronic recoils
below 15 keV from beta decays of tritium at drift fields of 92 V/cm, 154 V/cm
and 366 V/cm using the XENON100 detector. A data-to-simulation fitting method
based on Markov Chain Monte Carlo is used to extract the photon yields and
recombination fluctuations from the experimental data. The photon yields
measured at the two lower fields are in agreement with those from literature;
additional measurements at a higher field of 366 V/cm are presented. The
electronic and nuclear recoil discrimination as well as its dependence on the
drift field and photon detection efficiency are investigated at these low
energies. The results provide new measurements in the energy region of interest
for dark matter searches using liquid xenon.
[14]
oai:arXiv.org:1705.06655 [pdf] - 1583594
First Dark Matter Search Results from the XENON1T Experiment
Aprile, E.;
Aalbers, J.;
Agostini, F.;
Alfonsi, M.;
Amaro, F. D.;
Anthony, M.;
Arneodo, F.;
Barrow, P.;
Baudis, L.;
Bauermeister, B.;
Benabderrahmane, M. L.;
Berger, T.;
Breur, P. A.;
Brown, A.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Bütikofer, L.;
Calvén, J.;
Cardoso, J. M. R.;
Cervantes, M.;
Cichon, D.;
Coderre, D.;
Colijn, A. P.;
Conrad, J.;
Cussonneau, J. P.;
Decowski, M. P.;
de Perio, P.;
Di Gangi, P.;
Di Giovanni, A.;
Diglio, S.;
Eurin, G.;
Fei, J.;
Ferella, A. D.;
Fieguth, A.;
Fulgione, W.;
Rosso, A. Gallo;
Galloway, M.;
Gao, F.;
Garbini, M.;
Gardner, R.;
Geis, C.;
Goetzke, L. W.;
Grandi, L.;
Greene, Z.;
Grignon, C.;
Hasterok, C.;
Hogenbirk, E.;
Howlett, J.;
Itay, R.;
Kaminsky, B.;
Kazama, S.;
Kessler, G.;
Kish, A.;
Landsman, H.;
Lang, R. F.;
Lellouch, D.;
Levinson, L.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lombardi, F.;
Lopes, J. A. M.;
Manfredini, A.;
Mariş, I.;
Undagoitia, T. Marrodán;
Masbou, J.;
Massoli, F. V.;
Masson, D.;
Mayani, D.;
Messina, M.;
Micheneau, K.;
Molinario, A.;
Morå, K.;
Murra, M.;
Naganoma, J.;
Ni, K.;
Oberlack, U.;
Pakarha, P.;
Pelssers, B.;
Persiani, R.;
Piastra, F.;
Pienaar, J.;
Pizzella, V.;
Piro, M. -C.;
Plante, G.;
Priel, N.;
Rauch, L.;
Reichard, S.;
Reuter, C.;
Riedel, B.;
Rizzo, A.;
Rosendahl, S.;
Rupp, N.;
Saldanha, R.;
Santos, J. M. F. dos;
Sartorelli, G.;
Scheibelhut, M.;
Schindler, S.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Shagin, P.;
Shockley, E.;
Silva, M.;
Simgen, H.;
Sivers, M. v.;
Stein, A.;
Thapa, S.;
Thers, D.;
Tiseni, A.;
Trinchero, G.;
Tunnell, C.;
Vargas, M.;
Upole, N.;
Wang, H.;
Wang, Z.;
Wei, Y.;
Weinheimer, C.;
Wulf, J.;
Ye, J.;
Zhang, Y.;
Zhu, T.
Submitted: 2017-05-18, last modified: 2017-11-23
We report the first dark matter search results from XENON1T, a
$\sim$2000-kg-target-mass dual-phase (liquid-gas) xenon time projection chamber
in operation at the Laboratori Nazionali del Gran Sasso in Italy and the first
ton-scale detector of this kind. The blinded search used 34.2 live days of data
acquired between November 2016 and January 2017. Inside the (1042$\pm$12) kg
fiducial mass and in the [5, 40] $\mathrm{keV}_{\mathrm{nr}}$ energy range of
interest for WIMP dark matter searches, the electronic recoil background was
$(1.93 \pm 0.25) \times 10^{-4}$ events/(kg $\times$ day $\times
\mathrm{keV}_{\mathrm{ee}}$), the lowest ever achieved in a dark matter
detector. A profile likelihood analysis shows that the data is consistent with
the background-only hypothesis. We derive the most stringent exclusion limits
on the spin-independent WIMP-nucleon interaction cross section for WIMP masses
above 10 GeV/c${}^2$, with a minimum of 7.7 $\times 10^{-47}$ cm${}^2$ for
35-GeV/c${}^2$ WIMPs at 90% confidence level.
[15]
oai:arXiv.org:1704.05804 [pdf] - 1582670
Search for magnetic inelastic dark matter with XENON100
XENON collaboration;
Aprile, E.;
Aalbers, J.;
Agostini, F.;
Alfonsi, M.;
Amaro, F. D.;
Anthony, M.;
Arneodo, F.;
Barrow, P.;
Baudis, L.;
Bauermeister, B.;
Benabderrahmane, M. L.;
Berger, T.;
Breur, P. A.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Bütikofer, L.;
Calvén, J.;
Cardoso, J. M. R.;
Cervantes, M.;
Cichon, D.;
Coderre, D.;
Colijn, A. P.;
Conrad, J.;
Cussonneau, J. P.;
Decowski, M. P.;
de Perio, P.;
Di Gangi, P.;
Di Giovanni, A.;
Diglio, S.;
Eurin, G.;
Fei, J.;
Ferella, A. D.;
Fieguth, A.;
Franco, D.;
Fulgione, W.;
Rosso, A. Gallo;
Galloway, M.;
Gao, F.;
Garbini, M.;
Geis, C.;
Goetzke, L. W.;
Greene, Z.;
Grignon, C.;
Hasterok, C.;
Hogenbirk, E.;
Itay, R.;
Kaminsky, B.;
Kessler, G.;
Kish, A.;
Landsman, H.;
Lang, R. F.;
Lellouch, D.;
Levinson, L.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lombardi, F.;
Lopes, J. A. M.;
Manfredini, A.;
Maris, I.;
Undagoitia, T. Marrodán;
Masbou, J.;
Massoli, F. V.;
Masson, D.;
Mayani, D.;
Messina, M.;
Micheneau, K.;
Molinario, A.;
Murra, M.;
Naganoma, J.;
Ni, K.;
Oberlack, U.;
Pakarha, P.;
Pelssers, B.;
Persiani, R.;
Piastra, F.;
Pienaar, J.;
Pizzella, V.;
Piro, M. -C.;
Plante, G.;
Priel, N.;
Rauch, L.;
Reichard, S.;
Reuter, C.;
Rizzo, A.;
Rosendahl, S.;
Rupp, N.;
Santos, J. M. F. dos;
Sartorelli, G.;
Scheibelhut, M.;
Schindler, S.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Shagin, P.;
Silva, M.;
Simgen, H.;
Sivers, M. v.;
Stein, A.;
Thers, D.;
Tiseni, A.;
Trinchero, G.;
Tunnell, C.;
Vargas, M.;
Wang, H.;
Wei, Y.;
Weinheimer, C.;
Wulf, J.;
Ye, J.;
Zhanga, Y.
Submitted: 2017-04-19, last modified: 2017-10-31
We present the first search for dark matter-induced delayed coincidence
signals in a dual-phase xenon time projection chamber, using the 224.6 live
days of the XENON100 science run II. This very distinct signature is predicted
in the framework of magnetic inelastic dark matter which has been proposed to
reconcile the modulation signal reported by the DAMA/LIBRA collaboration with
the null results from other direct detection experiments. No candidate event
has been found in the region of interest and upper limits on the WIMP's
magnetic dipole moment are derived. The scenarios proposed to explain the
DAMA/LIBRA modulation signal by magnetic inelastic dark matter interactions of
WIMPs with masses of 58.0 GeV/c$^2$ and 122.7 GeV/c$^2$ are excluded at 3.3
$\sigma$ and 9.3 $\sigma$, respectively.
[16]
oai:arXiv.org:1709.02222 [pdf] - 1602622
Search for Bosonic Super-WIMP Interactions with the XENON100 Experiment
XENON collaboration;
Aprile, E.;
Aalbers, J.;
Agostini, F.;
Alfonsi, M.;
Althueser, L.;
Amaro, F. D.;
Anthony, M.;
Arneodo, F.;
Barrow, P.;
Baudis, L.;
Bauermeister, B.;
Benabderrahmane, M. L.;
Berger, T.;
Breur, P. A.;
Brown, A.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Bütikofer;
Calven, J.;
Capelli, C.;
Cardoso, J. M. R.;
Cichon, D.;
Coderre, D.;
Colijn, A. P.;
Conrad, J.;
Cussonneau, J. P.;
Decowski, M. P.;
de Perio, P.;
Di Gangi, P.;
Di Giovanni, A.;
Diglio, S.;
Eurin, G.;
Fei, J.;
Ferella, A. D.;
Fieguth, A.;
Fulgione, W.;
Rosso, A. Gallo;
Galloway, M.;
Gao, F.;
Garbini, M.;
Geis, C.;
Goetzke, L. W.;
Greene, Z.;
Grignon, C.;
Hasterok, C.;
Hogenbirk, E.;
Howlett, J.;
Itay, R.;
Kaminsky, B.;
Kazama, S.;
Kessler, G.;
Kish, A.;
Landsman, H.;
Lang, R. F.;
Lellouch, D.;
Levinson, L.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lombardi, F.;
Lopes, J. A. M.;
Manfredini, A.;
Maris, I.;
Undagoitia, T. Marrodán;
Masbou, J.;
Massoli, F. V.;
Masson, D.;
Mayani, D.;
Messina, M.;
Micheneau, K.;
Molinario, A.;
Morå, K.;
Murra, M.;
Naganoma, J.;
Ni, K.;
Oberlack, U.;
Pakarha, P.;
Pelssers, B.;
Persiani, R.;
Piastra, F.;
Pienaar, J.;
Pizzella, V.;
Piro, M. -C.;
Plante, G.;
Priel, N.;
García, D. Ramírez;
Rauch, L.;
Reichard, S.;
Reuter, C.;
Rizzo, A.;
Rupp, N.;
Santos, J. M. F. dos;
Sartorelli, G.;
Scheibelhut, M.;
Schindler, S.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Shagin, P.;
Silva, M.;
Simgen, H.;
Sivers, M. v.;
Stein, A.;
Thers, D.;
Tiseni, A.;
Trinchero, G.;
Tunnell, C.;
Vargas, M.;
Wang, H.;
Wang, Z.;
Wei, Y.;
Weinheimer, C.;
Wittweg, C.;
Wulf, J.;
Ye, J.;
Zhang, Y.;
Zhu, T.
Submitted: 2017-09-07
We present results of searches for vector and pseudo-scalar bosonic
super-WIMPs, which are dark matter candidates with masses at the keV-scale,
with the XENON100 experiment. XENON100 is a dual-phase xenon time projection
chamber operated at the Laboratori Nazionali del Gran Sasso. A profile
likelihood analysis of data with an exposure of 224.6 live days $\times$ 34\,kg
showed no evidence for a signal above the expected background. We thus obtain
new and stringent upper limits in the $(8-125)$\,keV/c$^2$ mass range,
excluding couplings to electrons with coupling constants of $g_{ae} >
3\times10^{-13}$ for pseudo-scalar and $\alpha'/\alpha > 2\times10^{-28}$ for
vector super-WIMPs, respectively. These limits are derived under the assumption
that super-WIMPs constitute all of the dark matter in our galaxy.
[17]
oai:arXiv.org:1708.07051 [pdf] - 1697916
The XENON1T Dark Matter Experiment
XENON Collaboration;
Aprile, E.;
Aalbers, J.;
Agostini, F.;
Alfonsi, M.;
Amaro, F. D.;
Anthony, M.;
Antunes, B.;
Arneodo, F.;
Balata, M.;
Barrow, P.;
Baudis, L.;
Bauermeister, B.;
Benabderrahmane, M. L.;
Berger, T.;
Breskin, A.;
Breur, P. A.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Bütikofer, L.;
Calvén, J.;
Cardoso, J. M. R.;
Cervantes, M.;
Chiarini, A.;
Cichon, D.;
Coderre, D.;
Colijn, A. P.;
Conrad, J.;
Corrieri, R.;
Cussonneau, J. P.;
Decowski, M. P.;
de Perio, P.;
Di Gangi, P.;
Di Giovanni, A.;
Diglio, S.;
Disdier, J. -M.;
Doets, M.;
Duchovni, E.;
Eurin, G.;
Fei, J.;
Ferella, A. D.;
Fieguth, A.;
Florin, D.;
Front, D.;
Fulgione, W.;
Rosso, A. Gallo;
Galloway, M.;
Gao, F.;
Garbini, M.;
Geis, C.;
Giboni, K. -L.;
Goetzke, L. W.;
Grandi, L.;
Greene, Z.;
Grignon, C.;
Hasterok, C.;
Hogenbirk, E.;
Huhmann, C.;
Itay, R.;
James, A.;
Kaminsky, B.;
Kazama, S.;
Kessler, G.;
Kish, A.;
Landsman, H.;
Lang, R. F.;
Lellouch, D.;
Levinson, L.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lombardi, F.;
Lopes, J. A. M.;
Maier, R.;
Manfredini, A.;
Maris, I.;
Undagoitia, T. Marrodán;
Masbou, J.;
Massoli, F. V.;
Masson, D.;
Mayani, D.;
Messina, M.;
Micheneau, K.;
Molinario, A.;
Morå, K.;
Murra, M.;
Naganoma, J.;
Ni, K.;
Oberlack, U.;
Orlandi, D.;
Othegraven, R.;
Pakarha, P.;
Parlati, S.;
Pelssers, B.;
Persiani, R.;
Piastra, F.;
Pienaar, J.;
Pizzella, V.;
Piro, M. -C.;
Plante, G.;
Priel, N.;
García, D. Ramírez;
Rauch, L.;
Reichard, S.;
Reuter, C.;
Rizzo, A.;
Rosendahl, S.;
Rupp, N.;
Santos, J. M. F. dos;
Saldahna, R.;
Sartorelli, G.;
Scheibelhut, M.;
Schindler, S.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Shagin, P.;
Shockley, E.;
Silva, M.;
Simgen, H.;
Sivers, M. v.;
Stern, M.;
Stein, A.;
Tatananni, D.;
Tatananni, L.;
Thers, D.;
Tiseni, A.;
Trinchero, G.;
Tunnell, C.;
Upole, N.;
Vargas, M.;
Wack, O.;
Walet, R.;
Wang, H.;
Wang, Z.;
Wei, Y.;
Weinheimer, C.;
Wittweg, C.;
Wulf, J.;
Ye, J.;
Zhang, Y.
Submitted: 2017-08-23
The XENON1T experiment at the Laboratori Nazionali del Gran Sasso (LNGS) is
the first WIMP dark matter detector operating with a liquid xenon target mass
above the ton-scale. Out of its 3.2t liquid xenon inventory, 2.0t constitute
the active target of the dual-phase time projection chamber. The scintillation
and ionization signals from particle interactions are detected with
low-background photomultipliers. This article describes the XENON1T instrument
and its subsystems as well as strategies to achieve an unprecedented low
background level. First results on the detector response and the performance of
the subsystems are also presented.
[18]
oai:arXiv.org:1705.02614 [pdf] - 1583194
Effective field theory search for high-energy nuclear recoils using the
XENON100 dark matter detector
Aprile, E.;
Aalbers, J.;
Agostini, F.;
Alfonsi, M.;
Amaro, F. D.;
Anthony, M.;
Arneodo, F.;
Barrow, P.;
Baudis, L.;
Bauermeister, B.;
Benabderrahmane, M. L.;
Berger, T.;
Breur, P. A.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Bütikofer, L.;
Calvén, J.;
Cardoso, J. M. R.;
Cervantes, M.;
Cichon, D.;
Coderre, D.;
Colijn, A. P.;
Conrad, J.;
Cussonneau, J. P.;
Decowski, M. P.;
de Perio, P.;
Di Gangi, P.;
Di Giovanni, A.;
Diglio, S.;
Eurin, G.;
Fei, J.;
Ferella, A. D.;
Fieguth, A.;
Fulgione, W.;
Rosso, A. Gallo;
Galloway, M.;
Gao, F.;
Garbini, M.;
Geis, C.;
Goetzke, L. W.;
Greene, Z.;
Grignon, C.;
Hasterok, C.;
Hogenbirk, E.;
Itay, R.;
Kaminsky, B.;
Kazama, S.;
Kessler, G.;
Kish, A.;
Landsman, H.;
Lang, R. F.;
Lellouch, D.;
Levinson, L.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lombardi, F.;
Lopes, J. A. M.;
Manfredini, A.;
Maris, I.;
Undagoitia, T. Marrodán;
Masbou, J.;
Massoli, F. V.;
Masson, D.;
Mayani, D.;
Messina, M.;
Micheneau, K.;
Molinario, A.;
Mora, K.;
Murra, M.;
Naganoma, J.;
Ni, K.;
Oberlack, U.;
Pakarha, P.;
Pelssers, B.;
Persiani, R.;
Piastra, F.;
Pienaar, J.;
Pizzella, V.;
Piro, M. -C.;
Plante, G.;
Priel, N.;
Rauch, L.;
Reichard, S.;
Reuter, C.;
Rizzo, A.;
Rosendahl, S.;
Rupp, N.;
Santos, J. M. F. dos;
Sartorelli, G.;
Scheibelhut, M.;
Schindler, S.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Shagin, P.;
Silva, M.;
Simgen, H.;
Sivers, M. v.;
Stein, A.;
Thers, D.;
Tiseni, A.;
Trinchero, G.;
Tunnell, C.;
Vargas, M.;
Wang, H.;
Wang, Z.;
Wei, Y.;
Weinheimer, C.;
Wulf, J.;
Ye, J.;
Zhang, Y.;
Farmer, B.
Submitted: 2017-05-07
We report on WIMP search results in the XENON100 detector using a
non-relativistic effective field theory approach. The data from science run II
(34 kg $\times$ 224.6 live days) was re-analyzed, with an increased recoil
energy interval compared to previous analyses, ranging from $(6.6 -
240)~\mathrm{keV_\mathrm{nr}}$. The data is found to be compatible with the
background-only hypothesis. We present 90% confidence level exclusion limits on
the coupling constants of WIMP-nucleon effective operators using a binned
profile likelihood method. We also consider the case of inelastic WIMP
scattering, where incident WIMPs may up-scatter to a higher mass state, and set
exclusion limits on this model as well.
[19]
oai:arXiv.org:1705.05830 [pdf] - 1943215
Search for WIMP Inelastic Scattering off Xenon Nuclei with XENON100
Aprile, E.;
Aalbers, J.;
Agostini, F.;
Alfonsi, M.;
Amaro, F. D.;
Anthony, M.;
Arneodo, F.;
Barrow, P.;
Baudis, L.;
Bauermeister, B.;
Benabderrahmane, M. L.;
Berger, T.;
Breur, P. A.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Bütikofer, L.;
Calvén, J.;
Cardoso, J. M. R.;
Cervantes, M.;
Cichon, D.;
Coderre, D.;
Colijn, A. P.;
Conrad, J.;
Cussonneau, J. P.;
Decowski, M. P.;
de Perio, P.;
Di Gangi, P.;
Di Giovanni, A.;
Diglio, S.;
Eurin, G.;
Fei, J.;
Ferella, A. D.;
Fieguth, A.;
Fulgione, W.;
Rosso, A. Gallo;
Galloway, M.;
Gao, F.;
Garbini, M.;
Geis, C.;
Goetzke, L. W.;
Greene, Z.;
Grignon, C.;
Hasterok, C.;
Hogenbirk, E.;
Itay, R.;
Kaminsky, B.;
Kazama, S.;
Kessler, G.;
Kish, A.;
Landsman, H.;
Lang, R. F.;
Lellouch, D.;
Levinson, L.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lombardi, F.;
Lopes, J. A. M.;
Manfredini, A.;
Maris, I.;
Undagoitia, T. Marrodán;
Masbou, J.;
Massoli, F. V.;
Masson, D.;
Mayani, D.;
Messina, M.;
Micheneau, K.;
Molinario, A.;
Mora, K.;
Murra, M.;
Naganoma, J.;
Ni, K.;
Oberlack, U.;
Pakarha, P.;
Pelssers, B.;
Persiani, R.;
Piastra, F.;
Pienaar, J.;
Pizzella, V.;
Piro, M. -C.;
Plante, G.;
Priel, N.;
Rauch, L.;
Reichard, S.;
Reuter, C.;
Rizzo, A.;
Rosendahl, S.;
Rupp, N.;
Santos, J. M. F. dos;
Sartorelli, G.;
Scheibelhut, M.;
Schindler, S.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Shagin, P.;
Silva, M.;
Simgen, H.;
Sivers, M. v.;
Stein, A.;
Thers, D.;
Tiseni, A.;
Trinchero, G.;
Tunnell, C.;
Vargas, M.;
Wang, H.;
Wang, Z.;
Wei, Y.;
Weinheimer, C.;
Wulf, J.;
Ye, J.;
Zhang, Y.
Submitted: 2017-05-01
We present the first constraints on the spin-dependent, inelastic scattering
cross section of Weakly Interacting Massive Particles (WIMPs) on nucleons from
XENON100 data with an exposure of 7.64$\times$10$^3$\,kg\,day. XENON100 is a
dual-phase xenon time projection chamber with 62\,kg of active mass, operated
at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy and designed to
search for nuclear recoils from WIMP-nucleus interactions. Here we explore
inelastic scattering, where a transition to a low-lying excited nuclear state
of $^{129}$Xe is induced. The experimental signature is a nuclear recoil
observed together with the prompt de-excitation photon. We see no evidence for
such inelastic WIMP-$^{129}$Xe interactions. A profile likelihood analysis
allows us to set a 90\% C.L. upper limit on the inelastic, spin-dependent
WIMP-nucleon cross section of $3.3 \times 10^{-38}$\,cm$^{2}$ at
100\,GeV/c$^2$. This is the most constraining result to date, and sets the
pathway for an analysis of this interaction channel in upcoming, larger
dual-phase xenon detectors.
[20]
oai:arXiv.org:1609.06154 [pdf] - 1531664
XENON100 Dark Matter Results from a Combination of 477 Live Days
XENON100 Collaboration;
Aprile, E.;
Aalbers, J.;
Agostini, F.;
Alfonsi, M.;
Amaro, F. D.;
Anthony, M.;
Arneodo, F.;
Barrow, P.;
Baudis, L.;
Bauermeister, B.;
Benabderrahmane, M. L.;
Berger, T.;
Breur, P. A.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Bütikofer, L.;
Calvén, J.;
Cardoso, J. M. R.;
Cervantes, M.;
Cichon, D.;
Coderre, D.;
Colijn, A. P.;
Conrad, J.;
Cussonneau, J. P.;
Decowski, M. P.;
de Perio, P.;
Di Gangi, P.;
Di Giovanni, A.;
Diglio, S.;
Duchovni, E.;
Fei, J.;
Ferella, A. D.;
Fieguth, A.;
Franco, D.;
Fulgione, W.;
Rosso, A. Gallo;
Galloway, M.;
Gao, F.;
Garbini, M.;
Geis, C.;
Goetzke, L. W.;
Greene, Z.;
Grignon, C.;
Hasterok, C.;
Hogenbirk, E.;
Itay, R.;
Kaminsky, B.;
Kessler, G.;
Kish, A.;
Landsman, H.;
Lang, R. F.;
Lellouch, D.;
Levinson, L.;
Calloch, M. Le;
Levy, C.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Manfredini, A.;
Undagoitia, T. Marrodán;
Masbou, J.;
Massoli, F. V.;
Masson, D.;
Mayani, D.;
Meng, Y.;
Messina, M.;
Micheneau, K.;
Miguez, B.;
Molinario, A.;
Murra, M.;
Naganoma, J.;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pakarha, P.;
Pelssers, B.;
Persiani, R.;
Piastra, F.;
Pienaar, J.;
Piro, M. -C.;
Plante, G.;
Priel, N.;
Rauch, L.;
Reichard, S.;
Reuter, C.;
Rizzo, A.;
Rosendahl, S.;
Rupp, N.;
Santos, J. M. F. dos;
Sartorelli, G.;
Scheibelhut, M.;
Schindler, S.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Shagin, P.;
Silva, M.;
Simgen, H.;
Sivers, M. v.;
Stein, A.;
Thers, D.;
Tiseni, A.;
Trinchero, G.;
Tunnell, C. D.;
Wall, R.;
Wang, H.;
Weber, M.;
Wei, Y.;
Weinheimer, C.;
Wulf, J.;
Zhang, Y.
Submitted: 2016-09-20, last modified: 2017-01-12
We report on WIMP search results of the XENON100 experiment, combining three
runs summing up to 477 live days from January 2010 to January 2014. Data from
the first two runs were already published. A blind analysis was applied to the
last run recorded between April 2013 and January 2014 prior to combining the
results. The ultra-low electromagnetic background of the experiment, ~$5 \times
10^{-3}$ events/(keV$_{\mathrm{ee}}\times$kg$\times$day) before electronic
recoil rejection, together with the increased exposure of 48 kg $\times$ yr
improves the sensitivity. A profile likelihood analysis using an energy range
of (6.6 - 43.3) keV$_{\mathrm{nr}}$ sets a limit on the elastic,
spin-independent WIMP-nucleon scattering cross section for WIMP masses above 8
GeV/$c^2$, with a minimum of 1.1 $\times 10^{-45}$ cm$^2$ at 50 GeV/$c^2$ and
90% confidence level. We also report updated constraints on the elastic,
spin-dependent WIMP-nucleon cross sections obtained with the same data. We set
upper limits on the WIMP-neutron (proton) cross section with a minimum of 2.0
$\times 10^{-40}$ cm$^2$ (52$\times 10^{-40}$ cm$^2$) at a WIMP mass of 50
GeV/$c^2$, at 90% confidence level.
[21]
oai:arXiv.org:1701.00769 [pdf] - 1542876
Search for Electronic Recoil Event Rate Modulation with 4 Years of
XENON100 Data
The XENON collaboration;
Aprile, E.;
Aalbers, J.;
Agostini, F.;
Alfonsi, M.;
Amaro, F. D.;
Anthony, M.;
Arneodo, F.;
Barrow, P.;
Baudis, L.;
Bauermeister, B.;
Benabderrahmane, M. L.;
Berger, T.;
Breur, P. A.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Butikofer, L.;
Calven, J.;
Cardoso, J. M. R.;
Cervantes, M.;
Cichon, D.;
Coderre, D.;
Colijn, A. P.;
Conrad, J.;
Cussonneau, J. P.;
Decowski, M. P.;
de Perio, P.;
Di Gangi, P.;
Di Giovanni, A.;
Diglio, S.;
Eurin, G.;
Fei, J.;
Ferella, A. D.;
Fieguth, A.;
Franco, D.;
Fulgione, W.;
Rosso, A. Gallo;
Galloway, M.;
Gao, F.;
Garbini, M.;
Geis, C.;
Goetzke, L. W.;
Greene, Z.;
Grignon, C.;
Hasterok, C.;
Hogenbirk, E.;
Itay, R.;
Kaminsky, B.;
Kessler, G.;
Kish, A.;
Landsman, H.;
Lang, R. F.;
Lellouch, D.;
Levinson, L.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Manfredini, A.;
Maris, I.;
Undagoitia, T. Marrodan;
Masbou, J.;
Massoli, F. V.;
Masson, D.;
Mayani, D.;
Messina, M.;
Micheneau, K.;
Miguez, B.;
Molinario, A.;
Murra, M.;
Naganoma, J.;
Ni, K.;
Oberlack, U.;
Pakarha, P.;
Pelssers, B.;
Persiani, R.;
Piastra, F.;
Pienaar, J.;
Pizzella, V.;
Piro, M. -C.;
Plante, G.;
Priel, N.;
Rauch, L.;
Reichard, S.;
Reuter, C.;
Rizzo, A.;
Rosendahl, S.;
Rupp, N.;
Santos, J. M. F. dos;
Sartorelli, G.;
Scheibelhut, M.;
Schindler, S.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Shagin, P.;
Silva, M.;
Simgen, H.;
Sivers, M. v.;
Stein, A.;
Thers, D.;
Tiseni, A.;
Trinchero, G.;
Tunnell, C.;
Wang, H.;
Wei, Y.;
Weinheimer, C.;
Wulf, J.;
Ye, J.;
Zhang, Y.
Submitted: 2017-01-03
We report on a search for electronic recoil event rate modulation signatures
in the XENON100 data accumulated over a period of 4 years, from January 2010 to
January 2014. A profile likelihood method, which incorporates the stability of
the XENON100 detector and the known electronic recoil background model, is used
to quantify the significance of periodicity in the time distribution of events.
There is a weak modulation signature at a period of $431^{+16}_{-14}$ days in
the low energy region of $(2.0-5.8)$ keV in the single scatter event sample,
with a global significance of $1.9\,\sigma$, however no other more significant
modulation is observed. The expected annual modulation of a dark matter signal
is not compatible with this result. Single scatter events in the low energy
region are thus used to exclude the DAMA/LIBRA annual modulation as being due
to dark matter electron interactions via axial vector coupling at
$5.7\,\sigma$.
[22]
oai:arXiv.org:1404.1455 [pdf] - 1693885
First Axion Results from the XENON100 Experiment
The XENON100 Collaboration;
Aprile, E.;
Agostini, F.;
Alfonsi, M.;
Arisaka, K.;
Arneodo, F.;
Auger, M.;
Balan, C.;
Barrow, P.;
Baudis, L.;
Bauermeister, B.;
Behrens, A.;
Beltrame, P.;
Bokeloh, K.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Cardoso, J. M. R.;
Colijn, A. P.;
Contreras, H.;
Cussonneau, J. P.;
Decowski, M. P.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Fulgione, W.;
Gao, F.;
Garbini, M.;
Geis, C.;
Goetzke, L. W.;
Grignon, C.;
Gross, E.;
Hampel, W.;
Itay, R.;
Kaether, F.;
Kessler, G.;
Kish, A.;
Landsman, H.;
Lang, R. F.;
Calloch, M. Le;
Lellouch, D.;
Levy, C.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lung, K.;
Lyashenko, A.;
Macmullin, S.;
Undagoitia, T. Marrodan;
Masbou, J.;
Massoli, F. V.;
Paras, D. Mayani;
Fernandez, A. J. Melgarejo;
Meng, Y.;
Messina, M.;
Miguez, B.;
Molinario, A.;
Murra, M.;
Naganoma, J.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Persiani, R.;
Piastra, F.;
Pienaar, J.;
Plante, G.;
Priel, N.;
Reichard, S.;
Reuter, C.;
Rizzo, A.;
Rosendahl, S.;
Santos, J. M. F. dos;
Sartorelli, G.;
Schindler, S.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Tiseni, A.;
Trinchero, G.;
Vitells, O.;
Wang, H.;
Weber, M.;
Weinheimer, C.
Submitted: 2014-04-05, last modified: 2016-12-22
We present the first results of searches for axions and axion-like-particles
with the XENON100 experiment. The axion-electron coupling constant, $g_{Ae}$,
has been probed by exploiting the axio-electric effect in liquid xenon. A
profile likelihood analysis of 224.6 live days $\times$ 34 kg exposure has
shown no evidence for a signal. By rejecting $g_{Ae}$, larger than $7.7 \times
10^{-12}$ (90\% CL) in the solar axion search, we set the best limit to date on
this coupling. In the frame of the DFSZ and KSVZ models, we exclude QCD axions
heavier than 0.3 eV/c$^2$ and 80 eV/c$^2$, respectively. For
axion-like-particles, under the assumption that they constitute the whole
abundance of dark matter in our galaxy, we constrain $g_{Ae}$, to be lower than
$1 \times 10^{-12}$ (90\% CL) for mass range from 1 to 40 keV/c$^2$, and set
the best limit to date as well.
[23]
oai:arXiv.org:1605.06262 [pdf] - 1530726
A low-mass dark matter search using ionization signals in XENON100
XENON100 Collaboration;
Aprile, E.;
Aalbers, J.;
Agostini, F.;
Alfonsi, M.;
Amaro, F. D.;
Anthony, M.;
Arneodo, F.;
Barrow, P.;
Baudis, L.;
Bauermeister, B.;
Benabderrahmane, M. L.;
Berger, T.;
Breur, P. A.;
Brown, A.;
Bruenner, E. Brown S.;
Bruno, G.;
Budnik, R.;
Buss, A.;
Bütikofer, L.;
Cardoso, J. M. R.;
Cervantes, M.;
Cichon, D.;
Coderre, D.;
Colijn, A. P.;
Conrad, J.;
Cussonneau, J. P.;
Decowski, M. P.;
de Perio, P.;
Di Gangi, P.;
Di Giovanni, A.;
Duchovni, E.;
Ferella, A. D.;
Fieguth, A.;
Franco, D.;
Fulgione, W.;
Galloway, M.;
Garbini, M.;
Geis, C.;
Goetzke, L. W.;
Greene, Z.;
Grignon, C.;
Gross, E.;
Hasterok, C.;
Hogenbirk, E.;
Itay, R.;
Kaminsky, B.;
Kessler, G.;
Kish, A.;
Landsman, H.;
Lang, R. F.;
Levinson, L.;
Calloch, M. Le;
Levy, C.;
Linde, F.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lyashenko, A.;
Manfredini, A.;
Undagoitia, T. Marrodán;
Masbou, J.;
Massoli, F. V.;
Masson, D.;
Mayani, D.;
Fernandez, A. J. Melgarejo;
Meng, Y.;
Messina, M.;
Micheneau, K.;
Miguez, B.;
Molinario, A.;
Murra, M.;
Naganoma, J.;
Oberlack, U.;
Orrigo, S. E. A.;
Pakarha, P.;
Pelssers, B.;
Persiani, R.;
Piastra, F.;
Pienaar, J.;
Plante, G.;
Priel, N.;
Rauch, L.;
Reichard, S.;
Reuter, C.;
Rizzo, A.;
Rosendahl, S.;
Rupp, N.;
Santos, J. M. F. dos;
Sartorelli, G.;
Scheibelhut, M.;
Schindler, S.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Stein, A.;
Thers, D.;
Tiseni, A.;
Trinchero, G.;
Tunnell, C. D.;
von Sivers, M.;
Wall, R.;
Wang, H.;
Weber, M.;
Wei, Y.;
Weinheimer, C.;
Wulf, J.;
Zhang, Y.
Submitted: 2016-05-20, last modified: 2016-12-19
We perform a low-mass dark matter search using an exposure of
30\,kg$\times$yr with the XENON100 detector. By dropping the requirement of a
scintillation signal and using only the ionization signal to determine the
interaction energy, we lowered the energy threshold for detection to 0.7\,keV
for nuclear recoils. No dark matter detection can be claimed because a complete
background model cannot be constructed without a primary scintillation signal.
Instead, we compute an upper limit on the WIMP-nucleon scattering cross section
under the assumption that every event passing our selection criteria could be a
signal event. Using an energy interval from 0.7\,keV to 9.1\,keV, we derive a
limit on the spin-independent WIMP-nucleon cross section that excludes WIMPs
with a mass of 6\,GeV/$c^2$ above $1.4 \times 10^{-41}$\,cm$^2$ at 90\%
confidence level.
[24]
oai:arXiv.org:1606.07001 [pdf] - 1525702
DARWIN: towards the ultimate dark matter detector
Aalbers, J.;
Agostini, F.;
Alfonsi, M.;
Amaro, F. D.;
Amsler, C.;
Aprile, E.;
Arazi, L.;
Arneodo, F.;
Barrow, P.;
Baudis, L.;
Benabderrahmane, M. L.;
Berger, T.;
Beskers, B.;
Breskin, A.;
Breur, P. A.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Buetikofer, L.;
Calven, J.;
Cardoso, J. M. R.;
Cichon, D.;
Coderre, D.;
Colijn, A. P.;
Conrad, J.;
Cussonneau, J. P.;
Decowski, M. P.;
Diglio, S.;
Drexlin, G.;
Duchovni, E.;
Erdal, E.;
Eurin, G.;
Ferella, A.;
Fieguth, A.;
Fulgione, W.;
Rosso, A. Gallo;
Di Gangi, P.;
Di Giovanni, A.;
Galloway, M.;
Garbini, M.;
Geis, C.;
Glueck, F.;
Grandi, L.;
Greene, Z.;
Grignon, C.;
Hasterok, C.;
Hannen, V.;
Hogenbirk, E.;
Howlett, J.;
Hilk, D.;
Hils, C.;
James, A.;
Kaminsky, B.;
Kazama, S.;
Kilminster, B.;
Kish, A.;
Krauss, L. M.;
Landsman, H.;
Lang, R. F.;
Lin, Q.;
Linde, F. L.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Undagoitia, T. Marrodan;
Masbou, J.;
Massoli, F. V.;
Mayani, D.;
Messina, M.;
Micheneau, K.;
Molinario, A.;
Mora, K. D.;
Morteau, E.;
Murra, M.;
Naganoma, J.;
Newstead, J. L.;
Ni, K.;
Oberlack, U.;
Pakarha, P.;
Pelssers, B.;
de Perio, P.;
Persiani, R.;
Piastra, F.;
Piro, M. C.;
Plante, G.;
Rauch, L.;
Reichard, S.;
Rizzo, A.;
Rupp, N.;
Santos, J. M. F. Dos;
Sartorelli, G.;
Scheibelhut, M.;
Schindler, S.;
Schumann, M.;
Schreiner, J.;
Lavina, L. Scotto;
Selvi, M.;
Shagin, P.;
Silva, M. C.;
Simgen, H.;
Sissol, P.;
von Sivers, M.;
Thers, D.;
Thurn, J.;
Tiseni, A.;
Trotta, R.;
Tunnell, C. D.;
Valerius, K.;
Vargas, M. A.;
Wang, H.;
Wei, Y.;
Weinheimer, C.;
Wester, T.;
Wulf, J.;
Zhang, Y.;
Zhu, T.;
Zuber, K.
Submitted: 2016-06-22
DARk matter WImp search with liquid xenoN (DARWIN) will be an experiment for
the direct detection of dark matter using a multi-ton liquid xenon time
projection chamber at its core. Its primary goal will be to explore the
experimentally accessible parameter space for Weakly Interacting Massive
Particles (WIMPs) in a wide mass-range, until neutrino interactions with the
target become an irreducible background. The prompt scintillation light and the
charge signals induced by particle interactions in the xenon will be observed
by VUV sensitive, ultra-low background photosensors. Besides its excellent
sensitivity to WIMPs above a mass of 5 GeV/c2, such a detector with its large
mass, low-energy threshold and ultra-low background level will also be
sensitive to other rare interactions. It will search for solar axions, galactic
axion-like particles and the neutrinoless double-beta decay of 136-Xe, as well
as measure the low-energy solar neutrino flux with <1% precision, observe
coherent neutrino-nucleus interactions, and detect galactic supernovae. We
present the concept of the DARWIN detector and discuss its physics reach, the
main sources of backgrounds and the ongoing detector design and R&D efforts.
[25]
oai:arXiv.org:1512.07501 [pdf] - 1395004
Physics reach of the XENON1T dark matter experiment
The XENON collaboration;
Aprile, E.;
Aalbers, J.;
Agostini, F.;
Alfonsi, M.;
Amaro, F. D.;
Anthony, M.;
Arazi, L.;
Arneodo, F.;
Balan, C.;
Barrow, P.;
Baudis, L.;
Bauermeister, B.;
Berger, T.;
Breur, P.;
Breskin, A.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Bütikofer, L.;
Cardoso, J. M. R.;
Cervantes, M.;
Cichon, D.;
Coderre, D.;
Colijn, A. P.;
Conrad, J.;
Contreras, H.;
Cussonneau, J. P.;
Decowski, M. P.;
de Perio, P.;
Di Gangi, P.;
Di Giovanni, A.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Fieguth, A.;
Franco, D.;
Fulgione, W.;
Galloway, M.;
Garbini, M.;
Geis, C.;
Goetzke, L. W.;
Greene, Z.;
Grignon, C.;
Gross, E.;
Hampel, W.;
Hasterok, C.;
Itay, R.;
Kaether, F.;
Kaminsky, B.;
Kessler, G.;
Kish, A.;
Landsman, H.;
Lang, R. F.;
Lellouch, D.;
Levinson, L.;
Calloch, M. Le;
Levy, C.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lyashenko, A.;
Macmullin, S.;
Manfredini, A.;
Undagoitia, T. Marrodán;
Masbou, J.;
Massoli, F. V.;
Mayani, D.;
Fernandez, A. J. Melgarejo;
Meng, Y.;
Messina, M.;
Micheneau, K.;
Miguez, B.;
Molinario, A.;
Murra, M.;
Naganoma, J.;
Oberlack, U.;
Orrigo, S. E. A.;
Pakarha, P.;
Pelssers, B.;
Persiani, R.;
Piastra, F.;
Pienaar, J.;
Plante, G.;
Priel, N.;
Rauch, L.;
Reichard, S.;
Reuter, C.;
Rizzo, A.;
Rosendahl, S.;
Rupp, N.;
Santos, J. M. F. dos;
Sartorelli, G.;
Scheibelhut, M.;
Schindler, S.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Stein, A.;
Thers, D.;
Tiseni, A.;
Trinchero, G.;
Tunnell, C.;
von Sivers, M.;
Wall, R.;
Wang, H.;
Weber, M.;
Wei, Y.;
Weinheimer, C.;
Wulf, J.;
Zhang, Y.
Submitted: 2015-12-23, last modified: 2016-04-15
The XENON1T experiment is currently in the commissioning phase at the
Laboratori Nazionali del Gran Sasso, Italy. In this article we study the
experiment's expected sensitivity to the spin-independent WIMP-nucleon
interaction cross section, based on Monte Carlo predictions of the electronic
and nuclear recoil backgrounds.
The total electronic recoil background in $1$ tonne fiducial volume and ($1$,
$12$) keV electronic recoil equivalent energy region, before applying any
selection to discriminate between electronic and nuclear recoils, is $(1.80 \pm
0.15) \cdot 10^{-4}$ ($\rm{kg} \cdot day \cdot keV)^{-1}$, mainly due to the
decay of $^{222}\rm{Rn}$ daughters inside the xenon target. The nuclear recoil
background in the corresponding nuclear recoil equivalent energy region ($4$,
$50$) keV, is composed of $(0.6 \pm 0.1)$ ($\rm{t} \cdot y)^{-1}$ from
radiogenic neutrons, $(1.8 \pm 0.3) \cdot 10^{-2}$ ($\rm{t} \cdot y)^{-1}$ from
coherent scattering of neutrinos, and less than $0.01$ ($\rm{t} \cdot y)^{-1}$
from muon-induced neutrons.
The sensitivity of XENON1T is calculated with the Profile Likelihood Ratio
method, after converting the deposited energy of electronic and nuclear recoils
into the scintillation and ionization signals seen in the detector. We take
into account the systematic uncertainties on the photon and electron emission
model, and on the estimation of the backgrounds, treated as nuisance
parameters. The main contribution comes from the relative scintillation
efficiency $\mathcal{L}_\mathrm{eff}$, which affects both the signal from WIMPs
and the nuclear recoil backgrounds. After a $2$ y measurement in $1$ t fiducial
volume, the sensitivity reaches a minimum cross section of $1.6 \cdot 10^{-47}$
cm$^2$ at m$_\chi$=$50$ GeV/$c^2$.
[26]
oai:arXiv.org:1507.03792 [pdf] - 1525674
Cosmogenic activation of xenon and copper
Submitted: 2015-07-14, last modified: 2015-09-07
Rare event search experiments using liquid xenon as target and detection
medium require ultra-low background levels to fully exploit their physics
potential. Cosmic ray induced activation of the detector components and, even
more importantly, of the xenon itself during production, transportation and
storage at the Earth's surface, might result in the production of radioactive
isotopes with long half-lives, with a possible impact on the expected
background. We present the first dedicated study on the cosmogenic activation
of xenon after 345 days of exposure to cosmic rays at the Jungfraujoch research
station at 3470m above sea level, complemented by a study of copper which has
been activated simultaneously. We have directly observed the production of 7Be,
101Rh, 125Sb, 126I and 127Xe in xenon, out of which only 125Sb could
potentially lead to background for a multi-ton scale dark matter search. The
production rates for five out of eight studied radioactive isotopes in copper
are in agreement with the only existing dedicated activation measurement, while
we observe lower rates for the remaining ones. The specific saturation
activities for both samples are also compared to predictions obtained with
commonly used software packages, where we observe some underpredictions,
especially for xenon activation.
[27]
oai:arXiv.org:1506.08309 [pdf] - 1292218
Dark matter sensitivity of multi-ton liquid xenon detectors
Submitted: 2015-06-27, last modified: 2015-09-03
We study the sensitivity of multi ton-scale time projection chambers using a
liquid xenon target, e.g., the proposed DARWIN instrument, to spin-independent
and spin-dependent WIMP-nucleon scattering interactions. Taking into account
realistic backgrounds from the detector itself as well as from neutrinos, we
examine the impact of exposure, energy threshold, background rejection
efficiency and energy resolution on the dark matter sensitivity. With an
exposure of 200 t x y and assuming detector parameters which have been already
demonstrated experimentally, spin-independent cross sections as low as $2.5
\times 10^{-49}$ cm$^2$ can be probed for WIMP masses around 40 GeV/$c^2$.
Additional improvements in terms of background rejection and exposure will
further increase the sensitivity, while the ultimate WIMP science reach will be
limited by neutrinos scattering coherently off the xenon nuclei.
[28]
oai:arXiv.org:1507.07748 [pdf] - 1268647
Search for Event Rate Modulation in XENON100 Electronic Recoil Data
The XENON Collaboration;
Aprile, E.;
Aalbers, J.;
Agostini, F.;
Alfonsi, M.;
Anthony, M.;
Arazi, L.;
Arisaka, K.;
Arneodo, F.;
Balan, C.;
Barrow, P.;
Baudis, L.;
Bauermeister, B.;
Breur, P. A.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Buetikofer, L.;
Cardoso, J. M. R.;
Cervantes, M.;
Coderre, D.;
Colijn, A. P.;
Contreras, H.;
Cussonneau, J. P.;
Decowski, M. P.;
de Perio, P.;
Di Giovanni, A.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Fieguth, A.;
Fulgione, W.;
Gao, F.;
Garbini, M.;
Geis, C.;
Goetzke, L. W.;
Grignon, C.;
Gross, E.;
Hampel, W.;
Hasterok, C.;
Itay, R.;
Kaether, F.;
Kaminsky, B.;
Kessler, G.;
Kish, A.;
Landsman, H.;
Lang, R. F.;
Calloch, M. Le;
Lellouch, D.;
Levinson, L.;
Levy, C.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lyashenko, A.;
Macmullin, S.;
Undagoitia, T. Marrodan;
Masbou, J.;
Massoli, F. V.;
Mayani, D.;
Meng, A. J. Melgarejo Fernandez. Y.;
Messina, M.;
Micheneau, K.;
Miguez, B.;
Molinario, A.;
Murra, M.;
Naganoma, J.;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pakarha, P.;
Persiani, R.;
Piastra, F.;
Pienaar, J.;
Plante, G.;
Priel, N.;
Rauch, L.;
Reichard, S.;
Reuter, C.;
Rizzo, A.;
Rosendahl, S.;
Santos, J. M. F. dos;
Sartorelli, G.;
Schindler, S.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Tiseni, A.;
Trinchero, G.;
Tunnell, C.;
Wall, R.;
Wang, H.;
Weber, M.;
Weinheimer, C.;
Zhang, Y.
Submitted: 2015-07-28
We have searched for periodic variations of the electronic recoil event rate
in the (2-6) keV energy range recorded between February 2011 and March 2012
with the XENON100 detector, adding up to 224.6 live days in total. Following a
detailed study to establish the stability of the detector and its background
contributions during this run, we performed an un-binned profile likelihood
analysis to identify any periodicity up to 500 days. We find a global
significance of less than 1 sigma for all periods suggesting no statistically
significant modulation in the data. While the local significance for an annual
modulation is 2.8 sigma, the analysis of a multiple-scatter control sample and
the phase of the modulation disfavor a dark matter interpretation. The
DAMA/LIBRA annual modulation interpreted as a dark matter signature with
axial-vector coupling of WIMPs to electrons is excluded at 4.8 sigma.
[29]
oai:arXiv.org:1507.07747 [pdf] - 1264865
Exclusion of Leptophilic Dark Matter Models using XENON100 Electronic
Recoil Data
The XENON Collaboration;
Aprile, E.;
Agostini, F.;
Alfonsi, M.;
Arazi, L.;
Arisaka, K.;
Arneodo, F.;
Auger, M.;
Balan, C.;
Barrow, P.;
Baudis, L.;
Bauermeister, B.;
Behrens, A.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Buetikofer, L.;
Cardoso, J. M. R.;
Cervantes, M.;
Coderre, D.;
Colijn, A. P.;
Contreras, H.;
Cussonneau, J. P.;
Decowski, M. P.;
Di Giovanni, A.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Fieguth, A.;
Fulgione, W.;
Gao, F.;
Garbini, M.;
Geis, C.;
Goetzke, L. W.;
Grignon, C.;
Gross, E.;
Hampel, W.;
Itay, R.;
Kaether, F.;
Kaminsky, B.;
Kessler, G.;
Kish, A.;
Landsman, H.;
Lang, R. F.;
Calloch, M. Le;
Lellouch, D.;
Levinson, L.;
Levy, C.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lyashenko, A.;
Macmullin, S.;
Undagoitia, T. Marrodan;
Masbou, J.;
Massoli, F. V.;
Paras, D. Mayani;
Fernandez, A. J. Melgarejo;
Meng, Y.;
Messina, M.;
Miguez, B.;
Molinario, A.;
Morana, G.;
Murra, M.;
Naganoma, J.;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pakarha, P.;
Pantic, E.;
Persiani, R.;
Piastra, F.;
Pienaar, J.;
Plante, G.;
Priel, N.;
Rauch, L.;
Reichard, S.;
Reuter, C.;
Rizzo, A.;
Rosendahl, S.;
Santos, J. M. F. dos;
Sartorelli, G.;
Schindler, S.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Tiseni, A.;
Trinchero, G.;
Tunnell, C.;
Vitells, O.;
Wall, R.;
Wang, H.;
Weber, M.;
Weinheimer, C.
Submitted: 2015-07-28
Laboratory experiments searching for galactic dark matter particles
scattering off nuclei have so far not been able to establish a discovery. We
use data from the XENON100 experiment to search for dark matter interacting
with electrons. With no evidence for a signal above the low background of our
experiment, we exclude a variety of representative dark matter models that
would induce electronic recoils. For axial-vector couplings to electrons, we
exclude cross-sections above 6x10^(-35) cm^2 for particle masses of m_chi = 2
GeV/c^2. Independent of the dark matter halo, we exclude leptophilic models as
explanation for the long-standing DAMA/LIBRA signal, such as couplings to
electrons through axial-vector interactions at a 4.4 sigma confidence level,
mirror dark matter at 3.6 sigma, and luminous dark matter at 4.6 sigma.
[30]
oai:arXiv.org:1503.07698 [pdf] - 1342737
Lowering the radioactivity of the photomultiplier tubes for the XENON1T
dark matter experiment
Aprile, E.;
Agostini, F.;
Alfonsi, M.;
Arazi, L.;
Arisaka, K.;
Arneodo, F.;
Auger, M.;
Balan, C.;
Barrow, P.;
Baudis, L.;
Bauermeister, B.;
Behrens, A.;
Beltrame, P.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Buetikofer, L.;
Cardoso, J. M. R.;
Coderre, D.;
Colijn, A. P.;
Contreras, H.;
Cussonneau, J. P.;
Decowksi, M. P.;
Di Giovanni, A.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Fieguth, A.;
Fulgione, W.;
Garbini, M.;
Geis, C.;
Goetzke, L. W.;
Grignon, C.;
Gross, E.;
Hampel, W.;
Itay, R.;
Kaether, F.;
Kessler, G.;
Kish, A.;
Landsman, H.;
Lang, R. F.;
Calloch, M. Le;
Lellouch, D.;
Levinson, L.;
Levy, C.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lyashenko, A.;
Macmullin, S.;
Undagoitia, T. Marrodan;
Masbou, J.;
Massoli, F. V.;
Mayani, D.;
Fernandez, A. J. Melgarejo;
Meng, Y.;
Messina, M.;
Miguez, B.;
Molinario, A.;
Morana, G.;
Murra, M.;
Naganoma, J.;
Oberlack, U.;
Orrigo, S. E. A.;
Pakarha, P.;
Pantic, E.;
Persiani, R.;
Piastra, F.;
Pienaar, J.;
Plante, G.;
Priel, N.;
Rauch, L.;
Reichard, S.;
Reuter, C.;
Rizzo, A.;
Rosendahl, S.;
Santos, J. M. F. dos;
Sartorelli, G.;
Schindler, S.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Tiseni, A.;
Trinchero, G.;
Tunnell, C.;
Vitells, O.;
Wall, R.;
Wang, H.;
Weber, M.;
Weinheimer, C.;
Laubenstein, M.
Submitted: 2015-03-26
The low-background, VUV-sensitive 3-inch diameter photomultiplier tube R11410
has been developed by Hamamatsu for dark matter direct detection experiments
using liquid xenon as the target material. We present the results from the
joint effort between the XENON collaboration and the Hamamatsu company to
produce a highly radio-pure photosensor (version R11410-21) for the XENON1T
dark matter experiment. After introducing the photosensor and its components,
we show the methods and results of the radioactive contamination measurements
of the individual materials employed in the photomultiplier production. We then
discuss the adopted strategies to reduce the radioactivity of the various PMT
versions. Finally, we detail the results from screening 216 tubes with
ultra-low background germanium detectors, as well as their implications for the
expected electronic and nuclear recoil background of the XENON1T experiment.
[31]
oai:arXiv.org:1406.2374 [pdf] - 940307
Conceptual design and simulation of a water Cherenkov muon veto for the
XENON1T experiment
Aprile, E.;
Agostini, F.;
Alfonsi, M.;
Arisaka, K.;
Arneodo, F.;
Auger, M.;
Balan, C.;
Barrow, P.;
Baudis, L.;
Bauermeister, B.;
Behrens, A.;
Beltrame, P.;
Bokeloh, K.;
Breskin, A.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Cardoso, J. M. R.;
Colijn, A. P.;
Contreras, H.;
Cussonneau, J. P.;
Decowski, M. P.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Fulgione, W.;
Garbini, M.;
Geis, C.;
Goetzke, L. W.;
Grignon, C.;
Gross, E.;
Hampel, W.;
Itay, R.;
Kaether, F.;
Kessler, G.;
Kish, A.;
Landsman, H.;
Lang, R. F.;
Calloch, M. Le;
Lellouch, D.;
Levinson, L.;
Levy, C.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lung, K.;
Lyashenko, A.;
MacMullin, S.;
Undagoitia, T. Marrodán;
Masbou, J.;
Massoli, F. V.;
Paras, D. Mayani;
Fernandez, A. J. Melgarejo;
Meng, Y.;
Messina, M.;
Miguez, B.;
Molinario, A.;
Morana, G.;
Murra, M.;
Naganoma, J.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Persiani, R.;
Piastra, F.;
Pienaar, J.;
Plante, G.;
Priel, N.;
Reichard, S.;
Reuter, C.;
Rizzo, A.;
Rosendahl, S.;
Santos, J. M. F. dos;
Sartorelli, G.;
Schindler, S.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Tiseni, A.;
Trinchero, G.;
Vitells, O.;
Wang, H.;
Weber, M.;
Weinheimer., C.
Submitted: 2014-06-09, last modified: 2015-02-25
XENON is a dark matter direct detection project, consisting of a time
projection chamber (TPC) filled with liquid xenon as detection medium. The
construction of the next generation detector, XENON1T, is presently taking
place at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy. It aims at a
sensitivity to spin-independent cross sections of $2 \cdot 10^{-47} ~
\mathrm{cm}^{\mathrm{2}}$ for WIMP masses around 50 GeV/c$^{2}$, which requires
a background reduction by two orders of magnitude compared to XENON100, the
current generation detector. An active system that is able to tag muons and
muon-induced backgrounds is critical for this goal. A water Cherenkov detector
of $\sim$10 m height and diameter has been therefore developed, equipped with 8
inch photomultipliers and cladded by a reflective foil. We present the design
and optimization study for this detector, which has been carried out with a
series of Monte Carlo simulations. The muon veto will reach very high detection
efficiencies for muons ($>99.5%$) and showers of secondary particles from muon
interactions in the rock ($>70%$). Similar efficiencies will be obtained for
XENONnT, the upgrade of XENON1T, which will later improve the WIMP sensitivity
by another order of magnitude. With the Cherenkov water shield studied here,
the background from muon-induced neutrons in XENON1T is negligible.
[32]
oai:arXiv.org:1501.01200 [pdf] - 1251898
Dark Matter 2014
Submitted: 2015-01-06
This article gives an overview on the status of experimental searches for
dark matter at the end of 2014. The main focus is on direct searches for weakly
interacting massive particles (WIMPs) using underground-based low-background
detectors, especially on the new results published in 2014. WIMPs are excellent
dark matter candidates, predicted by many theories beyond the standard model of
particle physics, and are expected to interact with the target nuclei either
via spin-independent (scalar) or spin-dependent (axial-vector) couplings.
Non-WIMP dark matter candidates, especially axions and axion-like particles are
also briefly discussed.
[33]
oai:arXiv.org:1405.7600 [pdf] - 862856
Dual-Phase Liquid Xenon Detectors for Dark Matter Searches
Submitted: 2014-05-29, last modified: 2014-08-07
Dual-phase time projection chambers (TPCs) filled with the liquid noble gas
xenon (LXe) are currently the most sensitive detectors searching for
interactions of WIMP dark matter in a laboratory-based experiment. This is
achieved by combining a large, monolithic dark matter target of a very low
background with the capability to localize the interaction vertex in three
dimensions, allowing for target fiducialization and multiple-scatter rejection.
The background in dual-phase LXe TPCs is further reduced by the simultaneous
measurement of the scintillation and ionization signal from a particle
interaction, which is used to distinguish signal from background signatures.
This article reviews the principle of dual-phase LXe TPCs, and provides an
overview about running as well as future experimental efforts.
[34]
oai:arXiv.org:1309.7024 [pdf] - 781479
Neutrino physics with multi-ton scale liquid xenon detectors
Submitted: 2013-09-26, last modified: 2014-02-07
We study the sensitivity of large-scale xenon detectors to low-energy solar
neutrinos, to coherent neutrino-nucleus scattering and to neutrinoless double
beta decay. As a concrete example, we consider the xenon part of the proposed
DARWIN (Dark Matter WIMP Search with Noble Liquids) experiment. We perform
detailed Monte Carlo simulations of the expected backgrounds, considering
realistic energy resolutions and thresholds in the detector. In a low-energy
window of 2-30 keV, where the sensitivity to solar pp and $^7$Be-neutrinos is
highest, an integrated pp-neutrino rate of 5900 events can be reached in a
fiducial mass of 14 tons of natural xenon, after 5 years of data. The
pp-neutrino flux could thus be measured with a statistical uncertainty around
1%, reaching the precision of solar model predictions. These low-energy solar
neutrinos will be the limiting background to the dark matter search channel for
WIMP-nucleon cross sections below $\sim$2$\times$10$^{-48}$ cm$^2$ and WIMP
masses around 50 GeV$\cdot$c$^{-2}$, for an assumed 99.5% rejection of
electronic recoils due to elastic neutrino-electron scatters. Nuclear recoils
from coherent scattering of solar neutrinos will limit the sensitivity to WIMP
masses below $\sim$6 GeV$\cdot$c$^{-2}$ to cross sections above
$\sim$4$\times$10$^{-45}$cm$^2$. DARWIN could reach a competitive half-life
sensitivity of 5.6$\times$10$^{26}$ y to the neutrinoless double beta decay of
$^{136}$Xe after 5 years of data, using 6 tons of natural xenon in the central
detector region.
[35]
oai:arXiv.org:1311.1088 [pdf] - 783783
Observation and applications of single-electron charge signals in the
XENON100 experiment
Aprile, E.;
Alfonsi, M.;
Arisaka, K.;
Arneodo, F.;
Balan, C.;
Baudis, L.;
Bauermeister, B.;
Behrens, A.;
Beltrame, P.;
Bokeloh, K.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Cardoso, J. M. R.;
Chen, W. -T.;
Choi, B.;
Colijn, A. P.;
Contreras, H.;
Cussonneau, J. P.;
Decowski, M. P.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Fulgione, W.;
Gao, F.;
Garbini, M.;
Ghag, C.;
Giboni, K. -L.;
Goetzke, L. W.;
Grignon, C.;
Gross, E.;
Hampel, W.;
Itay, R.;
Kaether, F.;
Kessler, G.;
Kish, A.;
Lamblin, J.;
Landsman, H.;
Lang, R. F.;
Calloch, M. Le;
Levy, C.;
Lim, K. E.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lung, K.;
Undagoitia, T. Marrodan;
Massoli, F. V.;
Fernandez, A. J. Melgarejo;
Meng, Y.;
Messina, M.;
Molinario, A.;
Naganoma, J.;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Persiani, R.;
Piastra, F.;
Plante, G.;
Priel, N.;
Rizzo, A.;
Rosendahl, S.;
Santos, J. M. F. dos;
Sartorelli, G.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Vitells, O.;
Wang, H.;
Weber, M.;
Weinheimer, C.
Submitted: 2013-11-05, last modified: 2014-01-28
The XENON100 dark matter experiment uses liquid xenon in a time projection
chamber (TPC) to measure xenon nuclear recoils resulting from the scattering of
dark matter Weakly Interacting Massive Particles (WIMPs). In this paper, we
report the observation of single-electron charge signals which are not related
to WIMP interactions. These signals, which show the excellent sensitivity of
the detector to small charge signals, are explained as being due to the
photoionization of impurities in the liquid xenon and of the metal components
inside the TPC. They are used as a unique calibration source to characterize
the detector. We explain how we can infer crucial parameters for the XENON100
experiment: the secondary-scintillation gain, the extraction yield from the
liquid to the gas phase and the electron drift velocity.
[36]
oai:arXiv.org:1310.5217 [pdf] - 862415
Dark Matter 2013
Submitted: 2013-10-19, last modified: 2013-11-28
This article reviews the status of the exciting and fastly evolving field of
dark matter research as of summer 2013, when it was discussed at ICRC 2013 in
Rio de Janeiro. It focuses on the three main avenues to detect WIMP dark
matter: direct detection, indirect detection and collider searches. The article
is based on the dark matter rapporteur talk summarizing the presentations given
at the conference, filling some gaps for completeness.
[37]
oai:arXiv.org:1207.3458 [pdf] - 1693882
Analysis of the XENON100 Dark Matter Search Data
The XENON100 Collaboration;
Aprile, E.;
Alfonsi, M.;
Arisaka, K.;
Arneodo, F.;
Balan, C.;
Baudis, L.;
Behrens, A.;
Beltrame, P.;
Bokeloh, K.;
Brown, E.;
Bruno, G.;
Budnik, R.;
Cardoso, J. M. R.;
Chen, W. -T.;
Choi, B.;
Cline, D. B.;
Contreras, H.;
Cussonneau, J. P.;
Decowski, M. P.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Fulgione, W.;
Gao, F.;
Garbini, M.;
Giboni, K. -L.;
Goetzke, L. W.;
Grignon, C.;
Gross, E.;
Hampel, W.;
Kish, A.;
Lamblin, J.;
Landsman, H.;
Lang, R. F.;
Calloch, M. Le;
Levy, C.;
Lim, K. E.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lung, K.;
Undagoitia, T. Marrodan;
Massoli, F. V.;
Mei, Y.;
Fernandez, A. J. Melgarejo;
Meng, Y.;
Molinario, A.;
Nativ, E.;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Persiani, R.;
Plante, G.;
Priel, N.;
Rizzo, A.;
Rosendahl, S.;
Santos, J. M. F. dos;
Sartorelli, G.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Scovell, P. R.;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Vitells, O.;
Wang, H.;
Weber, M.;
Weinheimer, C.
Submitted: 2012-07-14, last modified: 2013-10-14
The XENON100 experiment, situated in the Laboratori Nazionali del Gran Sasso,
aims at the direct detection of dark matter in the form of weakly interacting
massive particles (WIMPs), based on their interactions with xenon nuclei in an
ultra low background dual-phase time projection chamber. This paper describes
the general methods developed for the analysis of the XENON100 data. These
methods have been used in the 100.9 and 224.6 live days science runs from which
results on spin-independent elastic, spin-dependent elastic and inelastic
WIMP-nucleon cross-sections have already been reported.
[38]
oai:arXiv.org:1306.2303 [pdf] - 1171929
The neutron background of the XENON100 dark matter experiment
Aprile, E.;
Alfonsi, M.;
Arisaka, K.;
Arneodo, F.;
Balan, C.;
Baudis, L.;
Bauermeister, B.;
Behrens, A.;
Beltrame, P.;
Bokeloh, K.;
Brown, A.;
Brown, E.;
Bruno, G.;
Budnik, R.;
Cardoso, J. M. R.;
Chen, W. -T.;
Choi, B.;
Colijn, A. P.;
Contreras, H.;
Cussonneau, J. P.;
Decowski, M. P.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Fulgione, W.;
Gao, F.;
Garbini, M.;
Ghag, C.;
Giboni, K. -L.;
Goetzke, L. W.;
Grignon, C.;
Gross, E.;
Hampel, W.;
Kaether, F.;
Kish, A.;
Lamblin, J.;
Landsman, H.;
Lang, R. F.;
Calloch, M. Le;
Levy, C.;
Lim, K. E.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lung, K.;
Undagoitia, T. Marrodan;
Massoli, F. V.;
Fernandez, A. J. Melgarejo;
Meng, Y.;
Messina, M.;
Molinario, A.;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Persiani, R.;
Plante, G.;
Priel, N.;
Rizzo, A.;
Rosendahl, S.;
Santos, J. M. F. dos;
Sartorelli, G.;
Schreiner, J.;
Schumann, M.;
ScottoLavina, L.;
Scovell, P. R.;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Tziaferi, E.;
Vitells, O.;
Wang, H.;
Weber, M.;
Weinheimer, C.
Submitted: 2013-06-10, last modified: 2013-09-02
The XENON100 experiment, installed underground at the Laboratori Nazionali
del Gran Sasso (LNGS), aims to directly detect dark matter in the form of
Weakly Interacting Massive Particles (WIMPs) via their elastic scattering off
xenon nuclei. This paper presents a study on the nuclear recoil background of
the experiment, taking into account neutron backgrounds from ($\alpha$,n) and
spontaneous fission reactions due to natural radioactivity in the detector and
shield materials, as well as muon-induced neutrons. Based on Monte Carlo
simulations and using measured radioactive contaminations of all detector
components, we predict the nuclear recoil backgrounds for the WIMP search
results published by the XENON100 experiment in 2011 and 2012,
0.11$^{+0.08}_{-0.04}$ events and 0.17$^{+0.12}_{-0.07}$ events, respectively,
and conclude that they do not limit the sensitivity of the experiment.
[39]
oai:arXiv.org:1304.1427 [pdf] - 705114
Response of the XENON100 Dark Matter Detector to Nuclear Recoils
The XENON100 Collaboration;
Aprile, E.;
Alfonsi, M.;
Arisaka, K.;
Arneodo, F.;
Balan, C.;
Baudis, L.;
Bauermeister, B.;
Behrens, A.;
Beltrame, P.;
Bokeloh, K.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Cardoso, J. M. R.;
Chen, W. -T.;
Choi, B.;
Colijn, A. P.;
Contreras, H.;
Cussonneau, J. P.;
Decowski, M. P.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Fulgione, W.;
Gao, F.;
Garbini, M.;
Geis, C.;
Ghag, C.;
Giboni, K. -L.;
Goetzke, L. W.;
Grignon, C.;
Gross, E.;
Hampel, W.;
Itay, R.;
Kaether, F.;
Kessler, G.;
Kish, A.;
Lamblin, J.;
Landsman, H.;
Lang, R. F.;
Calloch, M. Le;
Levy, C.;
Lim, K. E.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lung, K.;
Undagoitia, T. Marrodan;
Massoli, F. V.;
Fernandez, A. J. Melgarejo;
Meng, Y.;
Messina, M.;
Molinario, A.;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Persiani, R.;
Plante, G.;
Priel, N.;
Rizzo, A.;
Rosendahl, S.;
Santos, J. M. F. dos;
Sartorelli, G.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Scovell, P. R.;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Vitells, O.;
Wang, H.;
Weber, M.;
Weinheimer, C.;
Schuhmacher, H.;
Wiegel, B.
Submitted: 2013-04-04, last modified: 2013-07-18
Results from the nuclear recoil calibration of the XENON100 dark matter
detector installed underground at the Laboratori Nazionali del Gran Sasso
(LNGS), Italy are presented. Data from measurements with an external 241AmBe
neutron source are compared with a detailed Monte Carlo simulation which is
used to extract the energy dependent charge-yield Qy and relative scintillation
efficiency Leff. A very good level of absolute spectral matching is achieved in
both observable signal channels - scintillation S1 and ionization S2 - along
with agreement in the 2-dimensional particle discrimination space. The results
confirm the validity of the derived signal acceptance in earlier reported dark
matter searches of the XENON100 experiment.
[40]
oai:arXiv.org:1303.6891 [pdf] - 682938
Response of liquid xenon to Compton electrons down to 1.5 keV
Submitted: 2013-03-27, last modified: 2013-06-12
The response of liquid xenon to low-energy electronic recoils is relevant in
the search for dark-matter candidates which interact predominantly with atomic
electrons in the medium, such as axions or axion-like particles, as opposed to
weakly interacting massive particles which are predicted to scatter with atomic
nuclei. Recently, liquid-xenon scintillation light has been observed from
electronic recoils down to 2.1 keV, but without applied electric fields that
are used in most xenon dark matter searches. Applied electric fields can reduce
the scintillation yield by hindering the electron-ion recombination process
that produces most of the scintillation photons. We present new results of
liquid xenon's scintillation emission in response to electronic recoils as low
as 1.5 keV, with and without an applied electric field. At zero field, a
reduced scintillation output per unit deposited energy is observed below 10
keV, dropping to nearly 40% of its value at higher energies. With an applied
electric field of 450 V/cm, we observe a reduction of the scintillation output
to about 75% relative to the value at zero field. We see no significant energy
dependence of this value between 1.5 keV and 7.8 keV. With these results, we
estimate the electronic-recoil energy thresholds of ZEPLIN-III, XENON10,
XENON100, and XMASS to be 2.8 keV, 2.5 keV, 2.3 keV, and 1.1 keV, respectively,
validating their excellent sensitivity to low-energy electronic recoils.
[41]
oai:arXiv.org:1303.0226 [pdf] - 656489
Performance of the Hamamatsu R11410 Photomultiplier Tube in cryogenic
Xenon Environments
Submitted: 2013-03-01, last modified: 2013-04-25
The Hamamatsu R11410 photomultiplier, a tube of 3" diameter and with a very
low intrinsic radioactivity, is an interesting light sensor candidate for
future experiments using liquid xenon (LXe) as target for direct dark matter
searches. We have performed several experiments with the R11410 with the goal
of testing its performance in environments similar to a dark matter detector
setup. In particular, we examined its long-term behavior and stability in LXe
and its response in various electric field configurations.
[42]
oai:arXiv.org:1207.5988 [pdf] - 642231
Dark Matter Results from 225 Live Days of XENON100 Data
XENON100 Collaboration;
Aprile, E.;
Alfonsi, M.;
Arisaka, K.;
Arneodo, F.;
Balan, C.;
Baudis, L.;
Bauermeister, B.;
Behrens, A.;
Beltrame, P.;
Bokeloh, K.;
Brown, E.;
Bruno, G.;
Budnik, R.;
Cardoso, J. M. R.;
Chen, W. -T.;
Choi, B.;
Cline, D.;
Colijn, A. P.;
Contreras, H.;
Cussonneau, J. P.;
Decowski, M. P.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Fulgione, W.;
Gao, F.;
Garbini, M.;
Ghag, C.;
Giboni, K. -L.;
Goetzke, L. W.;
Grignon, C.;
Gross, E.;
Hampel, W.;
Kaether, F.;
Kettling, H.;
Kish, A.;
Lamblin, J.;
Landsman, H.;
Lang, R. F.;
Calloch, M. Le;
Levy, C.;
Lim, K. E.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lung, K.;
Undagoitia, T. Marrodan;
Massoli, F. V.;
Fernandez, A. J. Melgarejo;
Meng, Y.;
Molinario, A.;
Nativ, E.;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Persiani, R.;
Plante, G.;
Priel, N.;
Rizzo, A.;
Rosendahl, S.;
Santos, J. M. F. dos;
Sartorelli, G.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Scovell, P. R.;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Vitells, O.;
Wang, H.;
Weber, M.;
Weinheimer, C.
Submitted: 2012-07-25, last modified: 2013-03-20
We report on a search for particle dark matter with the XENON100 experiment,
operated at the Laboratori Nazionali del Gran Sasso (LNGS) for 13 months during
2011 and 2012. XENON100 features an ultra-low electromagnetic background of
(5.3 \pm 0.6) \times 10^-3 events (kg day keVee)^-1 in the energy region of
interest. A blind analysis of 224.6 live days \times 34 kg exposure has yielded
no evidence for dark matter interactions. The two candidate events observed in
the pre-defined nuclear recoil energy range of 6.6-30.5 keVnr are consistent
with the background expectation of (1.0 \pm 0.2) events. A Profile Likelihood
analysis using a 6.6-43.3 keVnr energy range sets the most stringent limit on
the spin-independent elastic WIMP-nucleon scattering cross section for WIMP
masses above 8 GeV/c^2, with a minimum of 2 \times 10^-45 cm^2 at 55 GeV/c^2
and 90% confidence level.
[43]
oai:arXiv.org:1101.3866 [pdf] - 956174
Study of the electromagnetic background in the XENON100 experiment
XENON100 Collaboration;
Aprile, E.;
Arisaka, K.;
Arneodo, F.;
Askin, A.;
Baudis, L.;
Behrens, A.;
Bokeloh, K.;
Brown, E.;
Cardoso, J. M. R.;
Choi, B.;
Cline, D.;
Fattori, S.;
Ferella, A. D.;
Giboni, K. -L.;
Kish, A.;
Lam, C. W.;
Lamblin, J.;
Lang, R. F.;
Lim, K. E.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lung, K.;
Undagoitia, T. Marrodan;
Mei, Y.;
Fernandez, A. J. Melgarejo;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Plante, G.;
Ribeiro, A. C. C.;
Santorelli, R.;
Santos, J. M. F. dos;
Schumann, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Tziaferi, E.;
Wang, H.;
Weber, M.;
Weinheimer, C.
Submitted: 2011-01-20, last modified: 2013-02-21
The XENON100 experiment, located at the Laboratori Nazionali del Gran Sasso
(LNGS), aims to directly detect dark matter in the form of Weakly Interacting
Massive Particles (WIMPs) via their elastic scattering off xenon nuclei. We
present a comprehensive study of the predicted electronic recoil background
coming from radioactive decays inside the detector and shield materials, and
intrinsic contamination. Based on GEANT4 Monte Carlo simulations using a
detailed geometry together with the measured radioactivity of all detector
components, we predict an electronic recoil background in the WIMP-search
energy range (0-100 keV) in the 30 kg fiducial mass of less than 10e-2
events/(kg-day-keV), consistent with the experiment's design goal. The
predicted background spectrum is in very good agreement with the data taken
during the commissioning of the detector, in Fall 2009.
[44]
oai:arXiv.org:1301.6620 [pdf] - 704634
Limits on spin-dependent WIMP-nucleon cross sections from 225 live days
of XENON100 data
XENON100 collaboration;
Aprile, E.;
Alfonsi, M.;
Arisaka, K.;
Arneodo, F.;
Balan, C.;
Baudis, L.;
Bauermeister, B.;
Behrens, A.;
Beltrame, P.;
Bokeloh, K.;
Brown, A.;
Brown, E.;
Bruno, G.;
Budnik, R.;
Cardoso, J. M. R.;
Chen, W. -T.;
Choi, B.;
Colijn, A. P.;
Contreras, H.;
Cussonneau, J. P.;
Decowski, M. P.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Fulgione, W.;
Gao, F.;
Garbini, M.;
Ghag, C.;
Giboni, K. -L.;
Goetzke, L. W.;
Grignon, C.;
Gross, E.;
Hampel, W.;
Kaether, F.;
Kish, A.;
Lamblin, J.;
Landsman, H.;
Lang, R. F.;
Calloch, M. Le;
Lellouch, D.;
Levy, C.;
Lim, K. E.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lung, K.;
Undagoitia, T. Marrodan;
Massoli, F. V.;
Fernandez, A. J. Melgarejo;
Meng, Y.;
Messina, M.;
Molinario, A.;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Persiani, R.;
Plante, G.;
Priel, N.;
Rizzo, A.;
Rosendahl, S.;
Santos, J. M. F. dos;
Sartorelli, G.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Scovell, P. R.;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Vitells, O.;
Wang, H.;
Weber, M.;
Weinheimer, C.
Submitted: 2013-01-28, last modified: 2013-01-29
We present new experimental constraints on the elastic, spin-dependent
WIMP-nucleon cross section using recent data from the XENON100 experiment,
operated in the Laboratori Nazionali del Gran Sasso in Italy. An analysis of
224.6 live days x 34 kg of exposure acquired during 2011 and 2012 revealed no
excess signal due to axial-vector WIMP interactions with 129-Xe and 131-Xe
nuclei. This leads to the most stringent upper limits on WIMP-neutron cross
sections for WIMP masses above 6 GeV, with a minimum cross section of 3.5 x
10^{-40} cm^2 at a WIMP mass of 45 GeV, at 90% confidence level.
[45]
oai:arXiv.org:1211.0836 [pdf] - 1157501
The distributed Slow Control System of the XENON100 Experiment
Aprile, E.;
Alfonsi, M.;
Arisaka, K.;
Arneodo, F.;
Balan, C.;
Baudis, L.;
Behrens, A.;
Beltrame, P.;
Bokeloh, K.;
Brown, E.;
Bruno, G. M.;
Budnik, R.;
Calloch, M. Le;
Cardoso, J. M.;
Chen, W. -T.;
Choi, B.;
Contreras, H.;
Cussonneau, J. -P.;
Decowski, M. P.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Fulgione, W.;
Gao, F.;
Garbini, M.;
Giboni, K. -L.;
Goetzke, L.;
Grignon, C.;
Gross, E.;
Hampel, W.;
McKinsey, D. N.;
Kish, A.;
Lamblin, J.;
Lang, R. F.;
Levy, C.;
Lim, K. E.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lung, K.;
Manzur, A.;
Undagoitia, T. Marrodán;
Massoli, F. V.;
Mei, Y.;
Fernandez, A. J. Melgarejo;
Meng, Y.;
Molinario, A.;
Nativ, E.;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Patricio, J. V.;
Persiani, R.;
Plante, G.;
Priel, N.;
Ribeiro, A. C. C.;
Rizzo, A.;
Rosendahl, S.;
Santos, J. M. F. dos;
Sartorelli, G.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Scovell, P. R.;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Vitells, O.;
Wang, H.;
Weber, M.;
Weinheimer, C.
Submitted: 2012-11-05
The XENON100 experiment, in operation at the Laboratori Nazionali del Gran
Sasso (LNGS) in Italy, was designed to search for evidence of dark matter
interactions inside a volume of liquid xenon using a dual-phase time projection
chamber. This paper describes the Slow Control System (SCS) of the experiment
with emphasis on the distributed architecture as well as on its modular and
expandable nature. The system software was designed according to the rules of
Object-Oriented Programming and coded in Java, thus promoting code reusability
and maximum flexibility during commissioning of the experiment. The SCS has
been continuously monitoring the XENON100 detector since mid 2008, remotely
recording hundreds of parameters on a few dozen instruments in real time, and
setting emergency alarms for the most important variables.
[46]
oai:arXiv.org:1208.5762 [pdf] - 555466
Comment on "On the subtleties of searching for dark matter with liquid
xenon detectors"
The XENON Collaboration;
Aprile, E.;
Alfonsi, M.;
Arisaka, K.;
Arneodo, F.;
Balan, C.;
Baudis, L.;
Bauermeister, B.;
Behrens, A.;
Beltrame, P.;
Bokeloh, K.;
Brown, E.;
Bruno, G.;
Budnik, R.;
Cardoso, J. M. R.;
Chen, W. -T.;
Choi, B.;
Cline, D.;
Colijn, A. P.;
Contreras, H.;
Cussonneau, J. P.;
Decowski, M. P.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Fulgione, W.;
Gao, F.;
Garbini, M.;
Ghag, C.;
Giboni, K. -L.;
Goetzke, L. W.;
Grignon, C.;
Gross, E.;
Hampel, W.;
Kaether, F.;
Kish, A.;
Lamblin, J.;
Landsman, H.;
Lang, R. F.;
Calloch, M. Le;
Levy, C.;
Lim, K. E.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lung, K.;
Undagoitia, T. Marrodan;
Massoli, F. V.;
Fernandez, A. J. Melgarejo;
Meng, Y.;
Molinario, A.;
Nativ, E.;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Persiani, R.;
Plante, G.;
Priel, N.;
Rizzo, A.;
Rosendahl, S.;
Santos, J. M. F. dos;
Sartorelli, G.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Scovell, P. R.;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Vitells, O.;
Wang, H.;
Weber, M.;
Weinheimer, C.
Submitted: 2012-08-28
In a recent manuscript (arXiv:1208.5046) Peter Sorensen claims that
XENON100's upper limits on spin-independent WIMP-nucleon cross sections for
WIMP masses below 10 GeV "may be understated by one order of magnitude or
more". Having performed a similar, though more detailed analysis prior to the
submission of our new result (arXiv:1207.5988), we do not confirm these
findings. We point out the rationale for not considering the described effect
in our final analysis and list several potential problems with his study.
[47]
oai:arXiv.org:1206.2169 [pdf] - 523152
Dark Matter Search with liquid Noble Gases
Submitted: 2012-06-11
Dark matter detectors using the liquid noble gases xenon and argon as WIMP
targets have evolved rapidly in the last decade and will continue to play a
major role in the field. Due to the possibility to scale these detectors to
larger masses relatively easily, noble liquids will likely be the first
technology realizing a detector with a ton-scale target mass. In this article,
we summarize the basic concepts of liquid noble gas dark matter detectors and
review the current experimental status.
[48]
oai:arXiv.org:1107.2155 [pdf] - 474250
The XENON100 Dark Matter Experiment
XENON100 Collaboration;
Aprile, E.;
Arisaka, K.;
Arneodo, F.;
Askin, A.;
Baudis, L.;
Behrens, A.;
Brown, E.;
Cardoso, J. M. R.;
Choi, B.;
Cline, D.;
Fattori, S.;
Ferella, A. D.;
Giboni, K. L.;
Kish, A.;
Lam, C. W.;
Lang, R. F.;
Lim, K. E.;
Lopes, J. A. M.;
Undagoitia, T. Marrodan;
Mei, Y.;
Fernandez, A. J. Melgarejo;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Plante, G.;
Ribeiro, A. C. C.;
Santorelli, R.;
Santos, J. M. F. dos;
Schumann, M.;
Shagin, P.;
Teymourian, A.;
Tziaferi, E.;
Wang, H.;
Yamashita, M.
Submitted: 2011-07-11, last modified: 2012-02-08
The XENON100 dark matter experiment uses liquid xenon (LXe) in a time
projection chamber (TPC) to search for Xe nuclear recoils resulting from the
scattering of dark matter Weakly Interacting Massive Particles (WIMPs). In this
paper we present a detailed description of the detector design and present
performance results, as established during the commissioning phase and during
the first science runs.
The active target of XENON100 contains 62 kg of LXe, surrounded by an LXe
veto of 99 kg, both instrumented with photomultiplier tubes (PMTs) operating
inside the liquid or in Xe gas. The LXe target and veto are contained in a
low-radioactivity stainless steel vessel, embedded in a passive radiation
shield. The experiment is installed underground at the Laboratori Nazionali del
Gran Sasso (LNGS), Italy and has recently published results from a 100
live-days dark matter search. The ultimate design goal of XENON100 is to
achieve a spin-independent WIMP-nucleon scattering cross section sensitivity of
\sigma = 2x10^-45 cm^2 for a 100 GeV/c^2 WIMP.
[49]
oai:arXiv.org:1103.2125 [pdf] - 1052646
Gator: a low-background counting facility at the Gran Sasso Underground
Laboratory
Baudis, L.;
Ferella, A. D.;
Askin, A.;
Angle, J.;
Aprile, E.;
Bruch, T.;
Kish, A.;
Laubenstein, M.;
Manalaysay, A.;
Undagoitia, T. Marrodan;
Schumann, M.
Submitted: 2011-03-10, last modified: 2012-01-10
A low-background germanium spectrometer has been installed and is being
operated in an ultra-low background shield (the Gator facility) at the Gran
Sasso underground laboratory in Italy (LNGS). With an integrated rate of ~0.16
events/min in the energy range between 100-2700 keV, the background is
comparable to those of the world's most sensitive germanium detectors. After a
detailed description of the facility, its background sources as well as the
calibration and efficiency measurements are introduced. Two independent
analysis methods are described and compared using examples from selected sample
measurements. The Gator facility is used to screen materials for XENON, GERDA,
and in the context of next-generation astroparticle physics facilities such as
DARWIN.
[50]
oai:arXiv.org:1111.6251 [pdf] - 443813
DARWIN
Submitted: 2011-11-27
DARWIN is a design-study for a next-to-next generation experiment to directly
detect WIMP dark matter in a detector based on a liquid xenon/liquid argon
two-phase time projection chamber. This article describes the project, its
goals and challenges, and presents some of the recent R&D highlights
[51]
oai:arXiv.org:1109.4270 [pdf] - 427699
Limits on the release of Rb isotopes from a zeolite based 83mKr
calibration source for the XENON project
Hannen, V.;
Aprile, E.;
Arneodo, F.;
Baudis, L.;
Beck, M.;
Bokeloh, K.;
Ferella, A. D.;
Giboni, K.;
Lang, R. F.;
Lebeda, O.;
Ortjohann, H. -W.;
Schumann, M.;
Spalek, A.;
Venos, D.;
Weinheimer, C.
Submitted: 2011-09-20, last modified: 2011-10-06
The isomer 83mKr with its half-life of 1.83 h is an ideal calibration source
for a liquid noble gas dark matter experiment like the XENON project. However,
the risk of contamination of the detector with traces of the much longer lived
mother isotop 83Rb (86.2 d half-life) has to be ruled out. In this work the
release of 83Rb atoms from a 1.8 MBq 83Rb source embedded in zeolite beads has
been investigated. To do so, a cryogenic trap has been connected to the source
for about 10 days, after which it was removed and probed for the strongest 83Rb
gamma-rays with an ultra-sensitive Germanium detector. No signal has been
found. The corresponding upper limit on the released 83Rb activity means that
the investigated type of source can be used in the XENON project and similar
low-background experiments as 83mKr generator without a significant risk of
contaminating the detector. The measurements also allow to set upper limits on
the possible release of the isotopes 84Rb and 86Rb, traces of which were
created alongside the production of 83Rb at the Rez cyclotron.
[52]
oai:arXiv.org:1104.3121 [pdf] - 418418
Implications on Inelastic Dark Matter from 100 Live Days of XENON100
Data
XENON100 Collaboration;
Aprile, E.;
Arisaka, K.;
Arneodo, F.;
Askin, A.;
Baudis, L.;
Behrens, A.;
Bokeloh, K.;
Brown, E.;
Bruch, T.;
Bruno, G.;
Cardoso, J. M. R.;
Chen, W. -T.;
Choi, B.;
Cline, D.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Gao, F.;
Giboni, K. -L.;
Gross, E.;
Kish, A.;
Lam, C. W.;
Lamblin, J.;
Lang, R. F.;
Levy, C.;
Lim, K. E.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lung, K.;
Undagoitia, T. Marrodán;
Mei, Y.;
Fernandez, A. J. Melgarejo;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Persiani, R.;
Plante, G.;
Ribeiro, A. C. C.;
Santorelli, R.;
Santos, J. M. F. dos;
Sartorelli, G.;
Schumann, M.;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Vitells, O.;
Wang, H.;
Weber, M.;
Weinheimer, C.
Submitted: 2011-04-15, last modified: 2011-09-09
The XENON100 experiment has recently completed a dark matter run with 100.9
live-days of data, taken from January to June 2010. Events in a 48kg fiducial
volume in the energy range between 8.4 and 44.6 keVnr have been analyzed. A
total of three events have been found in the predefined signal region,
compatible with the background prediction of (1.8 \pm 0.6) events. Based on
this analysis we present limits on the WIMP-nucleon cross section for inelastic
dark matter. With the present data we are able to rule out the explanation for
the observed DAMA/LIBRA modulation as being due to inelastic dark matter
scattering off iodine at a 90% confidence level.
[53]
oai:arXiv.org:1103.0303 [pdf] - 427646
Likelihood Approach to the First Dark Matter Results from XENON100
XENON100 Collaboration;
Aprile, E.;
Arisaka, K.;
Arneodo, F.;
Askin, A.;
Baudis, L.;
Behrens, A.;
Bokeloh, K.;
Brown, E.;
Bruch, T.;
Cardoso, J. M. R.;
Choi, B.;
Cline, D.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Giboni, K. -L.;
Gross, E.;
Kish, A.;
Lam, C. W.;
Lamblin, J.;
Lang, R. F.;
Lim, K. E.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Undagoitia, T. Marrodán;
Mei, Y.;
Fernandez, A. J. Melgarejo;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Plante, G.;
Ribeiro, A. C. C.;
Santorelli, R.;
Santos, J. M. F. dos;
Schumann, M.;
Shagin, P.;
Teymourian, A.;
Thers, D.;
Tziaferi, E.;
Vitells, O.;
Wang, H.;
Weber, M.;
Weinheimer, C.
Submitted: 2011-03-01, last modified: 2011-09-07
Many experiments that aim at the direct detection of Dark Matter are able to
distinguish a dominant background from the expected feeble signals, based on
some measured discrimination parameter. We develop a statistical model for such
experiments using the Profile Likelihood ratio as a test statistic in a
frequentist approach. We take data from calibrations as control measurements
for signal and background, and the method allows the inclusion of data from
Monte Carlo simulations. Systematic detector uncertainties, such as
uncertainties in the energy scale, as well as astrophysical uncertainties, are
included in the model. The statistical model can be used to either set an
exclusion limit or to make a discovery claim, and the results are derived with
a proper treatment of statistical and systematic uncertainties. We apply the
model to the first data release of the XENON100 experiment, which allows to
extract additional information from the data, and place stronger limits on the
spin-independent elastic WIMP-nucleon scattering cross-section. In particular,
we derive a single limit, including all relevant systematic uncertainties, with
a minimum of 2.4x10^-44 cm^2 for WIMPs with a mass of 50 GeV/c^2.
[54]
oai:arXiv.org:1104.2549 [pdf] - 966664
Dark Matter Results from 100 Live Days of XENON100 Data
XENON100 Collaboration;
Aprile, E.;
Arisaka, K.;
Arneodo, F.;
Askin, A.;
Baudis, L.;
Behrens, A.;
Bokeloh, K.;
Brown, E.;
Bruch, T.;
Bruno, G.;
Cardoso, J. M. R.;
Chen, W. -T.;
Choi, B.;
Cline, D.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Gao, F.;
Giboni, K. -L.;
Gross, E.;
Kish, A.;
Lam, C. W.;
Lamblin, J.;
Lang, R. F.;
Levy, C.;
Lim, K. E.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lung, K.;
Undagoitia, T. Marrodan;
Mei, Y.;
Fernandez, A. J. Melgarejo;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Persiani, R.;
Plante, G.;
Ribeiro, A. C. C.;
Santorelli, R.;
Santos, J. M. F. dos;
Sartorelli, G.;
Schumann, M.;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Vitells, O.;
Wang, H.;
Weber, M.;
Weinheimer, C.
Submitted: 2011-04-13, last modified: 2011-09-07
We present results from the direct search for dark matter with the XENON100
detector, installed underground at the Laboratori Nazionali del Gran Sasso of
INFN, Italy. XENON100 is a two-phase time projection chamber with a 62 kg
liquid xenon target. Interaction vertex reconstruction in three dimensions with
millimeter precision allows to select only the innermost 48 kg as ultra-low
background fiducial target. In 100.9 live days of data, acquired between
January and June 2010, no evidence for dark matter is found. Three candidate
events were observed in a pre-defined signal region with an expected background
of 1.8 +/- 0.6 events. This leads to the most stringent limit on dark matter
interactions today, excluding spin-independent elastic WIMP-nucleon scattering
cross-sections above 7.0x10^-45 cm^2 for a WIMP mass of 50 GeV/c^2 at 90%
confidence level.
[55]
oai:arXiv.org:1101.5298 [pdf] - 368547
Background Measurements in the Gran Sasso Underground Laboratory
Submitted: 2011-01-27, last modified: 2011-04-16
The gamma background flux below 3000 keV in the Laboratori Nazionali del Gran
Sasso (LNGS), Italy, has been measured using a 3" diameter NaI(Tl) detector at
different underground positions: In hall A, hall B, the interferometer tunnel,
and inside the Large Volume Detector (LVD). The integrated flux is 0.3--0.4
s$^{-1}$cm$^{-2}$ at the first three locations, and is lower by two orders of
magnitude inside LVD. With the help of Monte Carlo simulations for every
location, the contribution of the individual primordial isotopes to the
background has been determined. Using an 11" diameter NaI(Tl) detector, the
background neutron flux in the LNGS interferometer tunnel has been estimated.
Within the uncertainties, the result agrees with those from other neutron
measurements in the main halls.
[56]
oai:arXiv.org:1005.0380 [pdf] - 325339
First Dark Matter Results from the XENON100 Experiment
The XENON100 Collaboration;
Aprile, E.;
Arisaka, K.;
Arneodo, F.;
Askin, A.;
Baudis, L.;
Behrens, A.;
Brown, E.;
Cardoso, J. M. R.;
Choi, B.;
Cline, D. B.;
Fattori, S.;
Ferella, A. D.;
Giboni, K. -L.;
Hugenberg, K.;
Kish, A.;
Lam, C. W.;
Lamblin, J.;
Lang, R. F.;
Lim, K. E.;
Lopes, J. A. M.;
Undagoitia, T. Marrodán;
Mei, Y.;
Fernandez, A. J. Melgarejo;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Plante, G.;
Ribeiro, A. C. C.;
Santorelli, R.;
Santos, J. M. F. dos;
Schumann, M.;
Shagin, P.;
Teymourian, A.;
Thers, D.;
Tziaferi, E.;
Wang, H.;
Weinheimer, C.
Submitted: 2010-05-03, last modified: 2011-03-01
The XENON100 experiment, in operation at the Laboratori Nazionali del Gran
Sasso in Italy, is designed to search for dark matter WIMPs scattering off 62
kg of liquid xenon in an ultra-low background dual-phase time projection
chamber. In this letter, we present first dark matter results from the analysis
of 11.17 live days of non-blind data, acquired in October and November 2009. In
the selected fiducial target of 40 kg, and within the pre-defined signal
region, we observe no events and hence exclude spin-independent WIMP-nucleon
elastic scattering cross-sections above 3.4 x 10^-44 cm^2 for 55 GeV/c^2 WIMPs
at 90% confidence level. Below 20 GeV/c^2, this result constrains the
interpretation of the CoGeNT and DAMA signals as being due to spin-independent,
elastic, light mass WIMP interactions.
[57]
oai:arXiv.org:1008.2661 [pdf] - 1034295
Modelling the time dependence of the TeV Gamma-ray source at the
Galactic Centre
Submitted: 2010-08-16
The physical mechanism behind the TeV gamma-ray source observed at the centre
of the Galaxy is still unknown. One intriguing possibility is that the
accretion flow onto the central supermassive black hole is responsible for
accelerating protons to TeV energies which then diffuse outward to interact
with molecular gas at distances of ~1 pc. Here, we build on our earlier
detailed calculations of the proton transport to consider the time and energy
dependence of the TeV signal following a burst of particle acceleration at Sgr
A*. We find that, due to the strong energy dependence of the proton diffusion,
any variability in the particle acceleration rate will only be visible in the
TeV signal after a delay of ~ 10 yrs, and only at energies >~ 10 TeV. If the
accelerator is long-lived it must have been running for at least 10^4 yrs and
have a hard proton injection spectrum of \alpha=0.7 (where dn/dE_inj \propto
E^{-\alpha}) in order to produce the correct amount of high energy gamma-ray
flux. This rapid diffusion of high energy protons also rules out the
possibility that the observed TeV source is directly related to the period of
increased activity of Sgr A* that ended ~ 100 yrs ago. However, a good fit to
the observed H.E.S.S. data was found with \alpha=2.7 for the scenario of a
brief (~few year long) burst of particle acceleration that occurred ~ 10 yrs
ago. If such bursts are common then they will keep the TeV source energised and
will likely produce spectral variability at >~ 10 TeV on <~ 5 yr timescales.
This model also implies that particle acceleration may be an important